MODEL: 47LPA. [2] ALARM OUTPUT 0: None 1: N.O. relay contact, 4 points 2: SPDT relay contact, 2 points. Digital Panel Meters 47 Series

Similar documents
MODEL: 47LV. Digital Panel Meters 47 Series

MODEL: AS4V. Plug-in Signal Conditioners M-UNIT

MODEL: KS. Plug-in Signal Conditioners K-UNIT

MODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4]

MODEL: M2XPA3. [2] EXCITATION 2: 4 V DC / 20 ma 3: 8 V DC / 20 ma 4: 12 V DC / 20 ma Configurator software is used to change the excitation value.

MODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4]

MODEL: 48NDV. Bargraph Indicators 48N Series

MODEL: W2TS. Mini-MW Series

[3] MOUNTING DIRECTION

MODEL: 48NDVD. Bargraph Indicators 48N Series

MODEL: M2VF MODEL: M2VF [1][2] [3][4]

MODEL: 48NAV. Bargraph Indicators 48N Series. [3] MOUNTING DIRECTION V: Vertical H: Horizontal

MODEL: DA3. Plug-in Signal Conditioners M-UNIT

MODEL: M1EXT. with Display M1E Series

MODEL: RPPD. Plug-in Signal Conditioners M-UNIT. [2] INPUT 2 Must be the same code as the one chosen for Input 1.

JRQ2 ENCODER POSITION TRANSMITTER MODEL. Plug-in Signal Conditioners M-UNIT. (field-programmable; built-in excitation)

MODEL: M2EXT. Super-mini Signal Conditioners with Display Mini-M M2E Series

MODEL: M2XU MODEL: M2XU [1][2] [3][4]

MODEL: JPR2. Plug-in Signal Conditioners M-UNIT

MODEL: W2DYS SEN TRONIC AG. Mini-MW Series

MODEL: M2SES SEN TRONIC AG [3] OUTPUT

MODEL: M2DYS SEN TRONIC AG

MODEL: MRP5. Final Control Elements. [2] TERMINAL BOX T: With

MODEL: R30US4. Remote I/O R30 Series

Adjustable Digital Process Instrument MDK480

MODEL: M6SXT. POWER INPUT DC Power R: 24 V DC

MODEL: MRP6. Final Control Elements

MODEL: JB2. Plug-in Signal Conditioners M-UNIT

MODEL: M6SXU MODEL: M6SXU [1][2] [3][4]

MODEL: 47DV. Digital Panel Meters 47 Series

MODEL: 27HU-B 27-UNIT. [3] LED INDICATOR 0: Without 1: With (SIL not available)

MODEL: DAST-20. Telemetering System

MODEL: 20VS2-02. Hybrid IC Isolation Amplifiers 20 Series

MODEL: M3LU2. OUTPUT Field-selectable Current 0 20 ma DC Voltage V DC V DC

DIGEM f 96 x 48 EK. Applications. Description

MODEL: 47DR. [2] EXCITATION SUPPLY 1: +12 V sensor excitation 2: +24 V two-wire transmitter excitation. Digital Panel Meters 47 Series

MODEL: R1C-GH. Remote I/O R1X Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

R24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY

Digital panelmeter with microprocessor based technology 5 digit. 4 free scalable setpoints/hysteresis/delay time (option)

Digital Indicator DS 96/24

MODEL: M3LU. OUTPUT Field-selectable Current 0 20 ma DC Voltage V DC V DC

MODEL: R3-RS8A. Remote I/O R3 Series. RTD INPUT MODULE (high accuracy, 8 points, isolated) MODEL: R3-RS8A[1][2]

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

MODEL: 27HU 27-UNIT MODEL: 27HU [1][2]

N30P DIGITAL PANEL METER

MODEL: 47DT. Digital Panel Meters 47 Series

MODEL: TC10EM. Temperature Controller TC10 Series

MODEL: B3HU. Space-saving Two-wire Signal Conditioners B3-UNIT

Digital Indicator DS 96/48 PK

JPQ2 PULSE ACCUMULATOR

ELECTRONIC DC INPUT METER

MID. Energy Management Energy Analyzer Type EM11 DIN. Product Description. How to order EM11 DIN AV8 1 X O1 PF. Type Selection EM11 DIN

Process displays For standard signals, temperature, resistance measurement

Application Alpha 20 Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters

SIA, SIB, SIC, SID. User's Manual

2 Pole CO, 8 A Plug-in 2 CO (DPDT) 1 CO (SPDT) 8/15 16/25* 250/ /400 2,000 4, /0.5/ /0.5/ (5/5) 300 (10/5)

Series 10-ZSE30A(F)/10-ISE30A

UNIVERSAL MEASURING INSTRUMENTS. TNM 34xx. TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument 1/49

Monitoring Relay MR 50

GC83 Digital Indicators & GC93 Digital Meter Relay

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:

60 Series - General purpose relays 6-10 A. Features Plug-in mount 10 A General purpose relay

SHIMADEN DIGITAL INDICATOR

Simplified Operations for TM-3100 Series Digital Tachometer

Multifunction-Panelmeter

62 Series - Power relays 16 A. Features / /

Solid-state Timer H3DS

ALPHA 20 MULTIFUNCTION METER (ALPHA SERIES)

HITEK POWER XR KW X-RAY POWER SUPPLY MODULE

Energy Management Modular Smart Power Transducer Type SPT-90

48 Series - Relay interface modules A. Features

Economical Digital Indicators For Process and Electrical Measurement

BASIC FEATURES C %RH. Shimaden, Temperature and Humidity Control Specialists. CP3701: Thermocouple Temperature Converter

Digital Panel Meter K3TE. Model Number Structure. Model Number Legend. Easy-to-use, Low-cost Digital Panel Meter that Accepts DC Input K3TE

И М. 2 24VAC 50/60Hz, 24-48VDC VAC 50/60Hz

Digital Panel Meters DC/AC Current and Voltage Indicator/Controller Type LDM40

Product Data Sheet RER225-63/18/2TDO- 406

Digital indicator for panel mounting With multi-function input Model DI25

Preset counters, electronic

AMIK 200 / 201 Technical Data Sheet

DP2000 ORDERING GUIDE To Order MODEL NO.

Contents H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A. Solid-state Timer. Common to ALL Timers

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models

Power analyzers and Energy Meters. Multifunction indicator. Type WM12-DIN. Product Description. How to order WM12-DIN AV5 3 D X.

JUMO dtrans T02 LCD programmable transmitter. B Operating Instructions 10.00/

48 SERIES. Relay interface modules 8 A CO forcibly guided contacts relay interface modules,15.8 mm wide Type 48.12

Ordering Information. PCB Relay G6RL. Model Number Legend: Low-profile power relay with maximum switching of 10 A

Model Number Structure

OMRON MK-I / -S RELAY

MODEL: MRP6D. POWER INPUT DC Power R: 24 V DC. Final Control Elements

IDEC RJ22 Series Slim Power Relays (Bifurcated Contacts)

SUBJECT TO CHANGE WITHOUT NOTICE

Solid-state Twin Timer

38 Series - Relay interface modules A. Features /

VM-703 TACHOMETER & ECCENTRICITY MONITOR MODULE Page 1 of 5

Relays & Sockets. RF2V 2-Pole Force Guided Relays/SJ Series Relay Sockets. UL/Recogntion File No. E55996 TÜV SÜD. EU Low Voltage Directive

Solid-state Timer H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A

Data Sheet. RISH Master Record %THD

MID. Energy Management Energy Meter Type EM23 DIN. Product Description. Type Selection. How to order EM23 DIN AV9 3 X O1 PF A EM23 DIN

UNIQUELY DESIGNED RELAY WITH HIGH SENSITIVITY. UL File No.: E43149 CSA File No.: LR26550

Transcription:

Digital Panel Meters 47 Series FREQUENCY INPUT DIGITAL PANEL METER (4½ digit, LED display type) Functions & Features 4 ½ digit digital panel meter 1/8 DIN size Accepts a pulse train input to measure rotation count or period Scaled reading representing speed (m/s), rotation (rpm) and other counts Alarm tone optional Max. and Min. value display IP66 front panel Separable terminal block Rear terminal cover for safety strapped to the meter 48 (1.89) HH H P L LL 96 (3.78) Zro Spn D/P Tch Fnc Min Max [2] ALARM OUTPUT 0: None 1: N.O. relay contact, 4 points 2: SPDT relay contact, 2 points [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White [4] POWER INPUT AC Power M2: 100 240 V AC (Operational voltage range 85 264 V, 50/60 Hz) DC Power R: 24 V DC (Operational voltage range 24 V ±10 %, ripple 10 %p-p max.) P: 110 V DC (Operational voltage range 85 150 V, ripple 10 %p-p max.) Max/Min Alarm/ Scale/ Shift Up 98.5 (3.88) mm (inch) -1[1][2][3]-[4][5] ORDERING INFORMATION Code number: 47LPA-1[1][2][3]-[4][5] Specify a code from below for each [1] through [5]. (e.g. 47LPA-1A1G-M2/B/Q) Specify the specification for option code /Q (e.g. /C01/S01/SET) INPUT 1: Open collector or voltage pulse [1] DC OUTPUT 0: Without Current A: 4 20 ma DC (Load resistance 550 Ω max.) D: 0 20 ma DC (Load resistance 550 Ω max.) Voltage 4: 0 10 V DC (Load resistance 10 kω min.) 5: 0 5 V DC (Load resistance 5000 Ω min.) 6: 1 5 V DC (Load resistance 5000 Ω min.) 4W: -10 +10 V DC (Load resistance 10 kω min.) [5] OPTIONS (multiple selections) Alarm Tone blank: Without /B: With (selectable only with alarm output) Other Options blank: none /Q: Option other than the above (specify the specification) SPECIFICATIONS OF OPTION: Q (multiple selections) COATING (For the detail, refer to M-System's web site.) Moving parts and indicators are not coated. /C01: Silicone coating /C02: Polyurethane coating /C03: Rubber coating TERMINAL SCREW MATERIAL /S01: Stainless steel EX-FACTORY SETTING /SET: Preset according to the Ordering Information Sheet (No. ESU-9515) GENERAL SPECIFICATIONS Construction: Panel flush mounting Degree of protection: IP66; applicable to the front of the panel meter mounted according to the specified panel cutout Connection: M3 separable screw terminal (torque 0.6 N m) Screw terminal: Nickel-plated steel (standard) or stainless steel 47LPA SPECIFICATIONS ES-9515 Rev.11 Page 1/8

Housing material: Flame-resistant resin (gray) Isolation: to DC output to HH output or H output to L output or LL output to power Setting: (Front button) Scaled range type Alarm setpoint Hysteresis (deadband) Others (Refer to the instruction manual for details) Lockout setting: Prohibiting certain operations; protecting settings DISPLAY Display: 16 mm (.63) high, 4 ½ digits, 7-segment LED indication: D/P turns on for 1 second after a valid pulse train has been detected (applied to 1/100 scaled signal for the input ranges F10K, F0.1M). Tch turns on with control input. Display range: -19999 to 19999 Decimal point position: 10 1, 10 2, 10 3, 10 4 or none Zero indication: Higher-digit zeros are suppressed. Over-range indication: -19999 or 19999 blinking for display values out of the scaled range. S.ERR and Max blinking when the input signal is out of the usable range. Alarm status indication LL indicator: Green LED turns on when the LL alarm is tripped. L indicator: Green LED turns on when the L alarm is tripped. H indicator: Red LED turns on when the H alarm is tripped. HH indicator: Red LED turns on when the HH alarm is tripped. P indicator: Amber LED turns on when none of the other alarms is tripped. Only P turns on with no-alarm-output type. LL or HH does not turn on with dual-alarm-output type. All setpoints can be independently set either for Hi or Lo alarm trip. Function indicators: Zro, Spn, D/P, Tch, Fnc, Min, Max Display mode status and operation status, amber ON or blink Engineering unit indication: Sticker label attached DC, AC, mv, V, kv, μa, ma, A, ka, mw, W, kw, var, kvar, Mvar, VA, Hz, Ω, kω, MΩ, cm, mm, m, m/sec, mm/min, cm/min, m/min, m/h, m/s 2, inch, l, l/s, l/min, l/h, m 3, m 3 /sec, m 3 /min, m 3 /h, Nm 3 /h, N m, N/m 2, g, kg, kg/h, N, kn, Pa, kpa, MPa, t, t/h,, F, %RH, J, kj, MJ, rpm, sec, min, min -1, ph, %, ppm, etc. INPUT SPECIFICATIONS Sensor excitation: 12 V DC ±10 %, 30 ma Current limit protection at approx. 60 ma Frequency range: 0 0.01 Hz through 100 khz A wave that has constant frequency and variable duty ratio cannot be measured. Time period range: 0 1 sec. through 100 sec. Minimum pulse width requirements: 5 μsec. for both ON and OFF Default setting: 0 100 khz Open Collector Detecting voltage/current: Approx. 8 V DC @ 1.6 ma Detecting levels: 300 Ω / 0.6 V for ON; 10 kω / 4.5 V for OFF Voltage Pulse Voltage range: 0 5 through 26.4 V ±5 ±26.4 V (equal amplitude at both poles, or ±10 V min. with frequency 50 khz) Waveform: Square (detecting sinking pulse edges) impedance: 10 kω Low level: -26.4 0.6 V DC High level: 4.5 26.4 V DC Control : Halt measuring Detecting time: 200 msec. Open collector Detecting voltag: 12V DC ±10 % Detecting level: 0.6 V for ON 4.5 V for OFF Voltage output range: 0 5 through 26.4 V ±5 ±26.4 V (equal amplitude at both poles) Low level: -26.4 +0.6 V DC High level: 4.5 26.4 V DC OUTPUT SPECIFICATIONS DC Output DC Current Operational range: -5 +105 % DC Voltage Operational range: -5 +105 % Alarm Output: Relay contact Rated load: 250 V AC @ 3 A (cos ø = 1) 30 V DC @ 3 A (resistive load) Maximum switching voltage: 250 V AC, 30 V DC Maximum switching power: 750 VA, 90 W (resistive load) Minimum load: 5 V DC @ 10 ma Mechanical life: 5 10 6 cycles (rate 180 cycles/min.) INSTALLATION Power consumption AC: Approx. 6.5VA 47LPA SPECIFICATIONS ES-9515 Rev.11 Page 2/8

DC: Approx. 3 W Operating temperature: -10 to +55 C (14 to 131 F) Operating humidity: 30 to 90 %RH (non-condensing) Mounting: Panel flush mounting Weight: 300 g (0.66 lb) PERFORMANCE Accuracy Display: ±0.1 % or ±1 digit Output: ±0.1 % (DC output = display + output) Temp. coefficient: ±0.015 %/ C (±0.008 %/ F) Output resolution: Max. 14 bits Response time: [One input cycle + 0.5 sec.] or less (alarm output: 0 100 % at 90 % setpoint) [One input cycle + 0.5 sec.] or less (DC output: 0 90 %) Line voltage effect: ±0.1 % over voltage range Insulation resistance: 100 MΩ with 500 V DC Dielectric strength: 2000 V AC @ 1 minute (input to DC output to HH output or H output to L output or LL output to power to ground) STANDARDS & APPROVALS EU conformity: EMC Directive EMI EN 61000-6-4 EMS EN 61000-6-2 Low Voltage Directive EN 61010-1 Measurement Category II (alarm output) Installation Category II (power) Pollution degree 2 or DC output to alarm output to power: Reinforced insulation (300 V) to DC output: Basic insulation (300 V) RoHS Directive EN 50581 Protection against access to the terminal blocks: Finger protection (VDE 0660-514) 47LPA SPECIFICATIONS ES-9515 Rev.11 Page 3/8

EXTERNAL VIEW (1) Main Display (2) Alarm Indicators (3) Function Indicators HH H P L LL Zro Spn D/P Tch Fnc Min Max Max/Min Alarm/ Scale/ Shift Up (4) Max/Min Button (5) Alarm/ Button (7) Shift Button (6) Scale/ Button (8) Up Button COMPONENT IDENTIFICATION No. COMPONENT FUNCTION (1) Main display Indicates present values, setting values and status of the unit. (2) Alarm indicators Indicate alarm status of the input signal. (3) Function indicators Indicate the status in each setting mode. (4) Max/Min button Used to switch the main display to show the present values, maximum values or minimum values etc. (5) Alarm/ button Used to confi rm alarm setting value and to move on to the alarm and other setting modes; or to shift through setting items in each setting mode. (6) Scale/ button Used to move on to the scaling and other setting modes; or to shift through setting items in each setting mode. (7) Shift button Used to move on to the setting standby status of each setting mode and shift through display digits in each setting mode. (8) Up button Used to select setting values in each setting mode. Note: Refer to the operating manual for details on each function. 47LPA SPECIFICATIONS ES-9515 Rev.11 Page 4/8

EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch) TOP VIEW 95 (3.74) FRONT VIEW 103 (4.06) SIDE VIEW 98.5 (3.88) 96 (3.78) 12.5 (.49) 86 (3.39) 2 (.08) 48 (1.89) 47 (1.85) REAR VIEW No Alarm Output Alarm Output 6.6 (.26) 10 M3 SCREW TERMINAL 20 M3 SCREW TERMINAL 2 M3 SCREW 4 M3 SCREW 45 (1.77) 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 91.5 (3.60) 47LPA SPECIFICATIONS ES-9515 Rev.11 Page 5/8

MOUNTING REQUIREMENTS unit: mm 92 + 0 0.8 min. 75 45 + 0 0.6 min. 120 Panel thickness: 1.6 to 8.0 mm 47LPA SPECIFICATIONS ES-9515 Rev.11 Page 6/8

SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM ALARM OUTPUT CODE 0: No alarm output EXC+ SHORT- CIRCUIT* 1 OC JP SENSOR EXCITATION INP+ INPUT COM CONTROL INPUT* 2 DI+ 1 2 3 4 5 Sensor Excitation Circuit Control 1/100 Scaler Digital Computation Isolation Output Driver 7 8 9 10 + DC OUTPUT U(+) POWER V( ) 6 Display / Setting ALARM OUTPUT CODE 1: N.O. contact, 4 points EXC+ SHORT- CIRCUIT* 1 OC JP SENSOR EXCITATION INP+ INPUT COM CONTROL INPUT* 2 DI+ 1 2 3 4 5 6 11 12 13 14 Sensor Excitation Circuit Control 1/100 Scaler Digital Computation Isolation Output Driver 7 8 15 16 17 18 19 20 + DC OUTPUT HHa HH OUTPUT Ha H OUTPUT Hc, HHc La L OUTPUT LLa LL OUTPUT Lc, LLc 9 10 U(+) V( ) POWER ALARM OUTPUT CODE 2: SPDT contact, 2 points EXC+ SHORT- CIRCUIT* 1 OC JP SENSOR EXCITATION INP+ INPUT COM CONTROL INPUT* 2 DI+ 1 2 3 4 5 Sensor Excitation Circuit Control 1/100 Scaler Digital Computation Isolation Output Driver 7 8 15 16 + DC OUTPUT Ha (NO) Hb (NC) H OUTPUT 6 11 12 13 14 17 18 19 20 Hc(COM) La (NO) Lb (NC) Lc(COM) L OUTPUT 9 10 U(+) V( ) POWER *1. Close across the terminals for open collector. Refer to the figure below. *2. For detailed connection of CONTROL INPUT, refer to the operating manual (EM-9515-B). Connection Example Open Collector Short 1 2 3 4 5 8V COM 5kΩ Relay Protection AC Powered LOAD U Inductive Load (Coil) Varistor or Spark Quenching Circuit DC Powered LOAD Inductive Load (Coil) Diode, Varistor or CR Circuit Note 1: The section enclosed by broken line is only with DC output option. Note 2: Chattering input signals cannot be measured accurately. Add a capacitor (10000 pf) or similar devices to the input terminals to eliminate the input signals instability. 47LPA SPECIFICATIONS ES-9515 Rev.11 Page 7/8

Specifications are subject to change without notice. 47LPA SPECIFICATIONS ES-9515 Rev.11 Page 8/8