WALKS AND SIDEWALKS REQUIREMENTS:

Similar documents
2016 CALIFORNIA BUILDING CODE - SECTION 11B-213 & DIVISION 6 GENERAL REQUIREMENTS FOR TOILET & BATHING FACILITIES

WEST HOLLYWOOD ACCESSIBLE UNISEX BATHROOMS: COMMERCIAL CLEARANCES. Accessible Unisex Bathrooms: Commercial Page 1 of 5

Priority 3 - Toilet Rooms

ACCESSIBILITY DETAILS FOR RESTROOMS AND DRINKING FOUNTAINS

Priority 3 - Toilet Rooms

Chapter 4. Accessible Routes

KEYS TO COMPLIANCE ASSEMBLY AND MERCANTILE OCCUPANCIES ACCESSIBLE TOILET COMPARTMENTS. Figure 16 Handrail cross section {505.7}

404 Doors, Doorways, and Gates

Accessible Toilet Stalls 6/18/03 1

I N T E R N A T I O N A L R E S I D E N T I A L CO D E

ACCESSIBILITY REQUIREMENTS FOR SINKS

City of Los Angeles Department of Building & Safety Disabled Access Section Supplemental Plan Review Checklist No. 2

IN T E R N A T I O N A L

CITY OF LONG BEACH Department of Development Services BUILDING AND SAFETY BUREAU SIGNS SUPPLEMENTAL ACCESSIBILITY PLAN REVIEW CHECKLIST NO.

I N T E R N A T I O N A L R E S I D E N T I A L CO D E

PLAN SUBMITTAL REQUIREMENTS

GRAF HALL ADA ASSESSMENT & SURVEY

DOCUMENT SUBMITTAL REQUIREMENTS FOR AN ALTERATION OR ADDITION TO AN EXISTING SINGLE-FAMILY DWELLING OR MULTI-FAMILY DWELLING

Paper Towel, Toilet Paper, Soap and Hand Sanitizer Dispensers

NCIDQ Restroom Drawing. Answers to the most common questions about this drawing for the Practicum Qpractice

SOFTBALL BLEACHER REPLACEMENT PROJECT 4000 SUISUN VALLEY ROAD, FAIRFIELD, CA PROJECT NO: APPLICATION NO: SUBMITTAL INDEX

DECK PERMIT APPLICATION PACKET

atm installation for accessibility a guide to ada/aba accessibility guidelines

REAR FRONT 93' 20' 12' 48' 120' 30' 52' 75' Sample Shopping Center. Unit # 5 +/- 10,920 GLA GROUND FLOOR. Width +/- 105' Depth +/- 120' Site Map

DOCUMENT SUBMITTAL REQUIREMENTS FOR A NEW MULTI-FAMILY DWELLING

APPLICATION FOR A BUILDING PERMIT

Residential Construction Checklist Single and Two Family Construction

External Timber Stairs

City of Lompoc Building & Safety Services Section 100 Civic Center Plaza Lompoc, CA Phone: Fax:

Environmental component, the complete Housing Enabler instrument. Susanne Iwarsson & Björn Slaug Yes

TO WHOM IT MAY CONCERN:

PATHWAY 3G MODULAR ACCESS SYSTEM

City of Thousand Oaks

Part 4: Visitability Ordinance. City of Austin Development Services Department

The maximum back wall height is eight-feet three-inches (8 3 ), including truss, and is allowed only in the rear half of the booth space.

Jackie Robinson Elementary School

Marcus Moziah Garvey Elementary School

Last updated 8/26/2013

DOCUMENT SUBMITTAL REQUIREMENTS FOR A NEW SINGLE-FAMILY DWELLING

Amos Alonzo Stagg Elementary School

PROGRAMMING SCHEMATIC DESIGN DESIGN DEVELOPMENT CONSTRUCTION DOCUMENTS. room) Scalable bubble diagrams schedules describing programmatic

Spiral Stairs Endeman s Ironcraft Ltd PH/FAX:

SECTION R507 DECKS DECKING LEDGER BOARD BEAM. FOOTING BEAM SPAN CANTILEVER For SI: 1 inch = 25.4 mm FIGURE R507.2 DECK CONSTRUCTION

grab BarS and rails 800 SerieS

ADDENDUM NOTICE INTERIOR RENOVATIONS AT THE BATHURST CLARK RESOURCE LIBRARY, 900 CLARK AVENUE WEST, VAUGHAN, ON

*********************************************************************************************************

ARCHITECTS SUPPLEMENTAL INSTRUCTIONS (ASI)

Travis County ESD #1. Building Plan Submittals. Information Bulletin. Fire Marshal Hancock

A1.1 FOX GARAGE VAN VAN VAN VAN 11/16/ WASHINGTON BLVD ST. LOUIS, MO REVISIONS FLOOR PLAN - LEVEL /01/14

Mahalia Jackson Elementary School 917 W 88th St Chicago, IL 60620

Everett McKinley Dirksen Elementary School

10. Vents, Baffle Guard and Blocking

ADDENDUM NO. 2. Germania Club Renovation Phase 2. Saginaw County Community Mental Health Authority WILLIAM A. KIBBE & ASSOCIATES, INC.

4. Special Systems Design: including Fire Alarm and Security. C. Electrical and Telecommunications Ductbanks: Refer to Section 16118

CHAPTER TWO Fire Lanes & Fire Access

Marcus Moziah Garvey Elementary School S Morgan St Chicago, IL 60643

The following information supplements and/or supersedes the bid documents issued on July 10, 2017.

The School District of Palm Beach County Project Name SDPBC Project No. SECTION ( ) SIGNAGE PART 1 GENERAL 1.1 RELATED DOCUMENTS

SECTION IDENTIFYING DEVICES

ELECTRICAL GENERAL DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL Electrical/Telecommunications Design

SECTION: 15 ZONING RULE LOT AREA 6134 S.F S.F. BUILDING AREA (FOOTPRINT) LOT COVERAGE 20.2% 24.86' FRONT YARD SIDE YARD 8.

2. Electrical rooms shall be centrally located and stacked so that feeder conduits and bus duct are run as straight and short as possible.

Mailing Address: Fax number: City: State: Zip: Property Owner: City: State: Zip: City: State: Zip:

SECTION IDENTIFYING DEVICES

Visual Interpretation Of The NTERNATIONAL ESIDENTIAL *** WITH NYS RESIDENTIAL CODE REQUIREMENTS AS NOTED. ~p..nuf:' >- ISMA~

When is a Building Permit Required? Deck Details: What Must be Submitted with a Building Permit Application?

INCOMPLETE APPLICATION WILL NOT BE ACCEPTED COMPLETE ALL INFORMATION BELOW. Construction Value: $

Temporary Sign Permit

INDEX OF SPECIFICATIONS SECTION F SPECIAL CONDITIONS DIVISION 1 - GENERAL REQUIREMENTS:

SECTION SIGNAGE

Wendell Smith Elementary School

STATE UNIVERSITY CONSTRUCTION FUND

Single-Family Dwelling Submittal Requirements

03/7/12 Issuance UTD Section Page 1 of 5 Electrical General

Architecture, Construction, and Engineering Technical Charter

Philip Rogers Elementary School 7345 N Washtenaw Ave Chicago, IL 60645

A. Submit properly identified manufacturer's literature before starting work.

DOCUMENT NARRATIVE PETSMART # 3131 GREEN VALLEY SAHUARITA, ARIZONA Construction Change Directive #1 (CCD-1) / September 22, 2017

Wall bracing is one of the most important structural elements of

Site Preparation Information for:

FILED: NEW YORK COUNTY CLERK 02/08/ :01 AM INDEX NO /2015 NYSCEF DOC. NO. 70 RECEIVED NYSCEF: 02/08/2018

Temporary Use Permit Application

Permits (Submitted to Permit Counter) APPLICATION CHECKLIST

Article 4.0 Measurements and Exceptions

ID0.1 PALO VERDE 8000 WEST US HIGHWAY 290 AUSTIN, TX SHEET INDEX: CONTACT INFORMATION: DISCLOSURES: DOCUMENT GENERAL NOTES:

Wendell E Green Elementary School 1150 W 96th St Chicago, IL 60643

INTERIOR SIGNAGE MANUAL

Construction Guidelines 1

EPIC Academy High School

Measuring Door Gap Dimensions of Swinging Fire Doors with Builders Hardware

Philip Rogers Elementary School

STAIRSERVICE.COM. Stair system design and selection catalog. A step ahead, a step above 1 (800) Fax (408)

Non-Residential and Multi-Family Plan Check Submittal Requirements

State College Area School District

BUILDING SIGN PROGRAM JULY 2012

SMALL PROJECTS & IMPROVEMENTS: DOG RUNS, PATIO ENCLOSURES & FENCES, EXTERIOR IMPROVEMENTS (Abbreviated Design Review Application)

Plan Submittal and Review Checklist

MEDICI ARTIST LOFTS. An affordable housing project by DFA dev. Artifex West Studio. 34 units - 7ea 3 bed, 17ea 2 bed & 10ea 1 bed

Disney II Magnet School

For Office Use: Filing Date: Case Number: Zoning District: LIST ALL ADDRESSES INVOLVED IN YOUR PROJECT:

Transcription:

DOUBLE PARKING STALLS DIAGONAL PARKING STALLS EXTERIOR ROUTES OF TRAVEL: From accessible parking spaces, provide most practical direct accessible route of travel to all building entrances and exteriorground level exits by incorporating pedestrian ramps, walks, and sidewalks. Any path of travel will be considered a ramp ifits slope is greater than 1:20 (5 percent) of horizontal run. WALKS AND SIDEWALKS REQUIREMENTS: Width = 48 Slope = 1 in 20 max. Abrupt Change in level along accessible route = Max 1/2, 1/4-1/2 beveled (1:2) 1 vertical to 2 horizontal Cross slope = Max 1/4 per foot Level areas at doors and gates = 60 x 60 swing side and 48 wide x 44 deep on push side Swing side strike edge clearance = 24 Hand rail not required RAMP REQUIREMENTS: Width = As required for stairways and exits and min 48 Slope = Max 1:12 Cross slope = Max 1:50 Landing = See illustration below Hand rail = Required with slope >1:20 Hand rail height = 34 to 38 Hand rail grip = 1 1/2 diameter RAMP DIMENSIONS

RAMP LANDING AND DOORWAY RAMPS AND SIDEWALKS STAIRWAYS: Construction of stairway shall comply with the standards stated below regardless of whether access is provided via elevators. HANDRAILS: Height = 34-38 Extension at top = 12 past top nosing Extension at bottom = 12 + tread width Mounting = 1 1/2 space from wall Grip = 1 1/4-1 1/2 or equivalent shape Risers = open risers are not permitted WARNING STRIPING AND HANDRAIL EXTENSIONS STAIR HANDRAILS

STAIR HANDRAILS DOORS: All entrances and exterior and interior exit doors regardless of the occupant load shall be made accessible to persons with disabilities. Size = Min 3-0 wide (32 clear when 90 open) and 6-8 in height Door hardware = operable with single effort without requiring ability to grasp hardware Effort to operate doors = 5 pounds at exterior doors and at interior doors Door hardware height = 30-44 above floor THRESHOLDS CLEAR DOOR WIDTH AND DEPTH DOOR CONSTRUCTION

DOOR HARDWARE OBSTRUCTIONS VESTIBULE LEVEL MANEUVERING CLEARANCE AT DOORS

BATHING AND TOILET FACILITIES: All sanitary facilities that serve buildings, facilities or portion of buildings that are required by handicapped regulations to be accessible to persons with disabilities shall comply. Where separate facilities are provided for each sex, these facilities shall be accessible to persons with disablities. Where unisex facilities are provided these facilities shall be provided to persons with disabilities. Where facilities are to be used solely by small children, the specific heights may be adjusted to meet their accessibility needs. TOILET ROOM FIXTURES AND ACCESSORIES: Water closet height = Min. 17 to max. 19 Water closet flush control = Max. 44 above floor Grab bars = 1 1/4 o - 1 1/2 o mounted at 33 above floor with 1 1/2 wall clearance Towel, sanitary napkins and waste receptacles = Max. 40 above floor Urinal = Min. 14 from wall and 17 above floor with operable control at max. 44 above floor MULTIPLE ACCOMMODATION TOILET FACILITY TOILET ACCESSORIES URINALS

KNEE CLEARANCE PLAN PLAN ELEVATION WATER FOUNTAINS (Drinking) AND PUBLIC TELEPHONE: When water fountains and public telephones are provided, they shall comply with handicapped regulations as illustrated below.

APPLICATION FOR UNREASONABLE HARDSHIP EXCEPTION Date Received Approved By DOCUMENTATION OF UNREASONABLE HARDSHIP Project Address: Owner: Applicant: Plan Check #: Telephone #: Telephone #: I hereby request the above named project be granted an unreasonable hardship exception from accessibility requirements of the 2007 California Building Code as specifically noted below. 2007 California Building Code Section 1134B.2.1 Exception: Applicable to existing buildings when the total construction cost of alterations, structural repairs or additions does not exceed a valuation threshold of $116,837.68 (valid until January 2008). COST JUSTIFICATION Access Features Cost of Making Feature Accessible *(Attach Documentation) 1. Path of travel to entrance $ 2. Entrance $ 3. Path of travel within building/facility to area of remodel $ 4. Sanitary facilities $ 5. Public telephones if provided $ 6. Drinking fountains if provided $ 7. Other (parking, signage, etc.) Specify $ Total cost of making feature accessible (A) $ Total cost of construction of this project making feature accessible (B) $ **Percentage of total cost of project (20% minimum to qualify): A B x 100% % *Please attach a breakdown of reasonable costs and/or a bonafide contractor s estimate of costs. **When the percentage is 20% or more, the project qualifies for unreasonable hardship and may be granted. The following individuals provided information listed in the above section: Architect Address Owner(s) Address Signature Date Signature Date