THE CHURCH OF J ESUS CHRIST OF LATTER-DAY SAINTS BISHOPS' STOREHOUSE THE CHURCH OF OF LATTER-DAY SAINTS HOME STORAGE CENTER BISHOPS' STOREHOUSE

Similar documents
OCPS Submittal Register for Product Data and Shop Drawing Reviews

Residential Construction Checklist Single and Two Family Construction

ADMINISTRATION DEPARTMENT Plant Management Division. An Inventory of Its State Office Building Drawings

2. All work and materials shall be in full accordance with Local and State ordinance and with any prevailing rules and regulations.

July 3, CASCO Project Managers St. Louis, Missouri PETSMART STORES. 13K Q Prototype Narrative (Delta 5) Bulletin No.

Measuring Door Gap Dimensions of Swinging Fire Doors with Builders Hardware

.1 Comply with the General Conditions of the Contract, Supplementary General Conditions and the requirements of Division 1.

Masonry Frames Interior/Exterior* Drywall Frames Interior**

HIA AIR CARGO HAMILTON ADDENDUM #3. Addendum No. A03 (Architectural) o Text 1 page o SK-10a o SK-10b o SK-11

Piping & Equipment Identification

FIRE RATED DOOR AND FRAME GENERAL REQUIREMENTS

NEW HOME WARRANTY A REFERENCE GUIDE FOR TYPICAL WALL AND WINDOW DETAILS (RAINSCREEN SYSTEM) SHOWN AS FIBRE CEMENT CLADDING

SECTION BULLET- RESISTANT DOORS

SCI-FAB Product Specifications. Casework Section 1. Part 1 General

SECTION IDENTIFICATION FOR PLUMBING PIPING AND EQUIPMENT

FIRE RATED DOOR AND FRAME GENERAL REQUIREMENTS

Deacon Corp. Three Week Schedule

03/7/12 Issuance UTD Section Page 1 of 5 Electrical General

B. Shop Drawings: Include elevations, door edge details, frame profiles, metal thicknesses, preparations for hardware, and other details.

PROGRAMMING SCHEMATIC DESIGN DESIGN DEVELOPMENT CONSTRUCTION DOCUMENTS. room) Scalable bubble diagrams schedules describing programmatic

Marshall Truck Station Laboratory Addition Project No. TZ MnDOT

CS2.0 COVER SHEET VOL. 2

Wendell E Green Elementary School 1150 W 96th St Chicago, IL 60643

CHAPTER 5 ARCHITECTURE

B. Shop Drawings: Include elevations, door edge details, frame profiles, metal thicknesses, preparations for hardware, and other details.

Versatrac Bypass Door Units, Conventional and Top Track, 300 and 400 Series

SECTION WOOD DOORS

BUILDING PLAN REVIEW REQUIREMENTS

SECTION MECHANICAL IDENTIFICATION

UNIFIED FACILITIES GUIDE SPECIFICATIONS

1.01 NOTICE TO BIDDERS

INSTALLATION SHOP DRAWINGS FOR MINNEAPOLIS, MN

CSP PSYCHIATRIC SERVICES UNIT SECTION IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT

University of Houston Master Construction Specifications Insert Project Name SECTION MECHANICAL SCOPE OF WORK PART 1 - GENERAL

SECTION MECHANICAL IDENTIFICATION

Series 7650 Installation Instructions Sliding Glass Door

Marcus Moziah Garvey Elementary School

ELECTRICAL GENERAL DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL Electrical/Telecommunications Design

2. Electrical rooms shall be centrally located and stacked so that feeder conduits and bus duct are run as straight and short as possible.

B. Shop Drawings: Include elevations, door edge details, frame profiles, metal thicknesses, preparations for hardware, and other details.

VNIV.EX454 - Sprinklers, Automatic and Open. Sprinklers, Automatic and Open

REVISION #1. Section. fire alarm B. C. the hot. intent of. required. manufacturer. materials. C. Warranty

Excavating, Backfilling, and Compaction for Utilities Piping (Plumbing).

SECTION MECHANICAL IDENTIFICATION. 1. Identification of mechanical products installed under Division 15.

B. Bidders shall acknowledge receipt of this Addendum in writing on his Proposal Form.

Hiram H Belding Elementary School 4257 N Tripp Ave Chicago, IL 60641

4. Special Systems Design: including Fire Alarm and Security. C. Electrical and Telecommunications Ductbanks: Refer to Section 16118

HAYES VALLEY PLAYGROUND AND CLUBHOUSE PROJECT NO.: SAN FRANCISCO PARKS AND RECREATIONS SAN FRANCISCO, CA

Infinity 20 Min. FIRE RATED DOORS WARNOCK HERSEY INFINITY - STANDARD RAISED - 20 MIN. RATING SOFTWOOD STILE

George Washington Elementary School 3611 E 114th St Chicago, IL 60617

C-Series & S-Series Classic Frame with Transom (Single or Pair)

at Fiddler s Creek Offered by

Ellen Mitchell Elementary School 2233 W Ohio St Chicago, IL 60612

Versatrac R-System Stock Extrusions, Clips and Accessories

b. B aluminum and aluminum-alloy extruded bar, rod, wire, shape and tube

To the Drawings and/or Specifications for. Board of Education of Harford County Lancaster, PA 17603

Tri-County Commercial Application Checklist

Sliding Glass Door Assembly and Installation Guide

Marcus Moziah Garvey Elementary School S Morgan St Chicago, IL 60643

SECTION HOLLOW METAL DOORS AND FRAMES

ARCHITECTS SUPPLEMENTAL INSTRUCTIONS (ASI)

Method of Build 1. Fire. Sound

EPIC Academy High School

Forcible Entry. Workbook Activities. Chapter Review

RENOVATION OF THE FARMERS MARKET Reference Number:

COMP 13 Replacement Parts

Chapter 12 - Windows and Doors

Langston Hughes Elementary School

CYPRESS FAIRBANKS MEDICAL CENTER HOSPITAL

1. Show the following information with additional information necessary to indicate shop compliance with the requirements of this section.

YSD 400 Sliding Door System Installation Manual

RECAPP Facility Evaluation Report

STEM Magnet Academy. Definitions EXTERIOR W Fillmore St Chicago, IL 60607

Heavy Wall Applied Stop Tube Frame and Door Installation

Symphony II Adaptable Table System

INSTALLATION INSTRUCTIONS FRAMELESS CONTINUOUS HINGE SHOWER ENCLOSURE QCI5233

Typical Drawings for Schools

Versatrac R-System Stock Extrusions, Clips and Accessories

State College Area School District

SAINT PAUL PUBLIC SCHOOLS Six Month Periodic Surveillance Report for Riverview Elementary 271 Belvidere Street East Saint Paul, MN Key

INSTALLATION INSTRUCTIONS FRAMELESS CONTINUOUS HINGE SHOWER ENCLOSURE QCI5232

ACME 50 Application Guide

PRODUCT DATA CATALOG

ADDENDUM #1. April 29, 2009

RECORD GROUP NUMBER 156

INTERIOR ALUMINUM DOORS AND FRAMES

UNIT No. 8150/9150 SHOWER ENCLOSURE

Almost Heaven Saunas THE AUTHENTIC SAUNA EXPERIENCE. Patterson Sauna Installation & Owner s Manual

Johann W von Goethe Elementary School 2236 N Rockwell St Chicago, IL 60647

SECTION HOLLOW METAL DOORS AND FRAMES

Nathanael Greene Elementary School 3525 S Honore St Chicago, IL 60609

DOCUMENT LIST OF DRAWINGS, TABLES AND SCHEDULES

PATIO INSTALLATION MANUAL

Architecture, Construction, and Engineering Technical Charter

Installation Instructions. 45 and 60-Minute Positive Pressure Fire-Rated Veneered Door Frame UBC & UL-10C

Charles P Caldwell Academy of Math & Science ES 8546 S Cregier Ave Chicago, IL 60617

Series 1600 WeatherGuard Dock Enclosure

Carpentry/Carpenter CIP Task Grid

Almost Heaven Saunas THE AUTHENTIC SAUNA EXPERIENCE. Worthington Sauna Installation & Owner s Manual

Versatrim Side-Snap Frame

Transcription:

231 THE CHURCH OF J ESUS CHRIST OF LATTER-DAY SAINTS BISHOPS' THE CHURCH OF BISHOPS' HOURS Monday-Friday P.M. - X:00 A.M. X:00 Saturday P.M. - X:00 A.M. X:00 J ESUS CHRIST OF LATTER-DAY SAINTS HOME STORAGE CENTER BISHOPS' Closed Sundays Cover Sheet COO1

Occupancy and Exiting Plan C002

FLOOR PLANS A1.1

ROOF PLAN Title A102

REFLECTED CEILING PLAN A103

WALL TYPES PLAN A104

231 EXTERIOR ELEVATIONS THE CHURCH OF J ESUS CHRIST THE CHURCH OF BISHOPS' OF LATTER-DAY SAINTS BISHOPS' J ESUS CHRIST OF LATTER-DAY SAINTS HOURS Monday-Friday P.M. - X:00 A.M. X:00 Saturday P.M. - X:00 A.M. X:00 HOME STORAGE CENTER Closed Sundays A201

BUILDING SECTIONS A301

WALL SECTIONS A302

STAIR AND LADDER SECTIONS A303

ENLARGED PLANS AND ELEVATIONS A401

ENLARGED PLANS AND ELEVATIONS A402

ENLARGED PLANS AND ELEVATIONS A403

LOADING DOCK A404

MISCELLANEOUS DETAILS A501

CANOPY DETAILS A502

FIXED 1 FIXED 6 FRAME TYPES (NOT USED) 2 3 4 5 STEEL A ALUMINUM (NOT USED) B FRAME PROFILES S SIZE T DESCRIPTION S1 S2 S3 S4 S5 S6 S7 G G1 G2 G3 T1 T2 T3 T4 3'-0" x 7'-0" (NOT USED) 8'-0" x 7'-0" 12'-0" x 10'-0" 3'-4" x 8'-0" 4'-6" x 7'-0" 8'-0" x 10'-0" GLASS (NOT USED) 1/4" TEMPERED PLATE (SINGLE GLAZE) CLEAR ACRYLIC THRESHOLD METAL THRESHOLD STONE THRESHOLD ARMORED JOINT METAL W/ VERTICAL LEG W/ NEOPRENE SEAL MARK 101A ROOM TYPE DOOR PAIR SINGLE SIZE GLAZING PROFILE 101B 101 E S1 G2 B 1 102A 102 G S1 G3 A 6 103A 103 104A 104 113A 101 E S1 G2 B 1 113 D O O R S C H E D U L E FRAME TYPE A S1 A 3 A S1 105A 105 B S1 G2 106A 106 K S2 - - HEAD FRAME DETAILS JAMB 107A 107 K S2 - - A/A803 B/A803 108A 110A 110 110B 110 S6 A S1 A 4 110C 111 A S1 A 4 111A 115 THRESH. N/A602 G S1 G3 A 6 AA/A602 Z/A602 J/A602 - A S1 A 4 W/A602 X/A602 M/A602 T1 THRESHOLD T1 T1 M/A602 T1 M/A602 T1 W/A602 X/A602 M/A602 T1 ACOUSTICAL SEALS REMARKS MOTOR OPERATED MOTOR OPERATED G S1 G3 A 6 AA/A602 Z/A602 J/A602 - DOOR SIZE NOMINAL 112A 114 A S1 A 4 114A 114B 201A 108 114 114 114C 114 116A 116 201 - - S6 A A - 3 3 - - G/A602 G/A602 AA/A602 V/A602 V/A602 V/A602 A/A803 G/A602 G/A602 Z/A602 V/A602 V/A602 V/A602 B/A803 N/A602 L S4 - - T/A602 Q/A602 P/A602 - MOTOR OPERATED L S7 - - T/A602 Q/A602 P/A602 - MOTOR OPERATED A S1 A 4 W/A602 X/A602 M/A602 T1 A S1 A 4 Y/A602 Y/A602 SIM. Y/A602 T4 ROOF ACCESS J/A602 G/A803 G/A803 T3 T3 W/A602 X/A602 M/A602 T1 R/A602 S/A602 J/A602 T2 T2 SEE SPECIFICATIONS FOR HARDWARE GROUPS MOTOR OPERATED MOTOR OPERATED FREEZER DOOR COOLER DOOR HOLLOW METAL DOOR A HOLLOW METAL DOOR B GLAZING DOOR TYPES (NOT USED) C (NOT USED) SL SL ALUMINUM SLIDING DOORS GLAZING (NOT USED) RIGID TRAFFIC DOOR WITH BREAKAWAY PANIC EXIT D E F G VISION LITE BUMPERS (BOTH SIDES OF EACH LEAF) F8 F4 B3 F4 W1 SPRING ADJUSTOR F8 F4 F4 B3 W1 F8 D A602 A B A602 SLIDING PASS THROUGH WINDOW B DIMENSIONS SHOWN ARE ROUGH OPENING WINDOW TYPES FREEZER AND COOLER DOOR K COILING STEEL DOOR L MOTOR DRIVE DISCONNECT CHAIN F7 F4 F4 B2 F4 W1 F4 W3 B5 F4 W2 W1 FINISHES LEGEND CMU - PAINT GYPSUM WALL BOARD - PAINT FLOOR FINISHES LEGEND T2 B1 F4 W3 B1 F4 W3 (NOT USED) F1 CARPET W3 B1 B2 B3 TILE TILE BASE RUBBER BASE LONG TOE RUBBER BASE F2 F3 F4 F5 PAVER TILE (NOT USED) POLISHED CONCRETE RESILIENT TILE W1 F7 F4 T1 W1 B2 B2 F1 B4 T1 W1 F4 T1 W1 B2 DOOR SCHEDULE FLOOR FINISH PLAN, DOOR & WINDOW TYPES B4 CARPET BASE F6 (NOT USED) F4 W1 (NOT USED) F7 CONCRETE SLAB- PAINTED B2 T1 T2 CROWN MOLDING TRIM METAL TRIM, FREEZER/COOLER TRIM F8 PEST DETECTION STRIP - PAINT 12" WHITE BAND AROUND ENTIRE PERIMETER OF ROOM A601

- - - - - - - - - - - - - - Mark Date (D-M-Y) Description DOOR AND WINDOW DETAILS A602

WAREHOUSE COLD STORAGE ENLARGED PLANS A801

COLD STORAGE DETAILS A802

COLD STORAGE DETAILS A803

COLD STORAGE ENLARGED PLAN AND DETAILS A804

THE CHURCH OF ESUS CHRIST OF LATTER-DAY SAINTS BISHOPS' 231 BROOKS STREET HOME STORAGE CENTER BISHOPS' Monday, Tuesday 00:00 A.M. -0:00 Wednesday - Friday 00:00 A.M. -0:00 Saturday 00:00 A.M. -0:00 P.M. P.M. P.M. HOME STORAGE CENTER Monday, Tuesday 00:00 A.M. -0:00 Wednesday - Friday 00:00 A.M. -0:00 Saturday 00:00 A.M. -0:00 P.M. Or by Appointment P.M. P.M. EMERGENCY EXIT ONLY ALARM WILL SOUND BISHOPS' HOME STORAGE CENTER CUSTODIAL WORKROOM OFFICE COOLER FREEZER REST ROOM FURNISHING AND EQUIPMENT PLANS F101

FURNISHING AND SINAGE PLANS F102

GENERAL STRUCTURAL NOTES AND MATERIAL PROPERTIES S001

SPECIAL INSPECTION AND QUALITY ASSURANCE REQUIREMENTS S002

FOOTING AND FOUNDATION PLAN S101

ROOF FRAMING PLAN S102

MEZZANINE FRAMING PLAN S103

FOOTING AND FOUNDATION DETAILS S511

FOOTING AND FOUNDATION DETAILS S512

FOOTING AND FOUNDATION DETAILS S513

FOOTING FOUNDATION DETAILS S514

ROOF FRAMING DETAILS S521

ROOF FRAMING DETAILS S522

SCHEDULES S601

DESIGN CRITERIA 1. DESIGN AREA BISHOPS' WAREHOUSE 110, WAREHOUSE COOLER 106, WAREHOUSE FREEZER 107 NFPA13-2013 Section 5.6.2 Pallet Types - For ceiling-only sprinkler protection, an increase in commodity classification is not required where the sprinkler system uses sprinklers with a minimum K-factor of K-16.8. NFPA13-2013 Section 16 Protection of Rack Storage of Class I Through Class IV Commodities That Are Stored on Racks - Table 16.2.1.3.2 Single- or Double-Row Racks - Storage Height Over 12 ft Up to and Including 25 ft - Figure 16.2.1.3.2(c) Sprinkler System Design Curves - 20 ft High Rack Storage - Class III Nonencapsulated Commodities - Conventional Pallets - Curve E - Design: 0.37 gpm/sq ft over 2000 sq ft - Storage height: 12 to 20 ft - Ceiling height: 24-25 ft Warehouse 110 19 ft Cooler 106 and Freezer 107 - Ceiling-level protection guidelines - sprinkler K-factor: 16.8 - sprinkler orientation: upright - sprinkler linear spacing: 8'-0" ft min, 12'-0" ft max - sprinkler protection area: 100 sq ft max - Hose stream demand: 500 gpm LEGEND SECTION A-A SCALE: 18"=1'-0" FIRE PROTECTION FLOOR PLAN SCALE: 18"=1'-0" FIRE PROTECTION PLANS FIRE PROTECTION MEZZANINE FLOOR PLAN DRY PENDENT SPRINKLER HEAD DETAIL SCALE: 18"=1'-0" DRY SPRINKLER BOOT & ESCUTCHEON DETAIL NOT TO SCALE NOT TO SCALE FIRE PROTECTION SITE PLAN SCALE: 1"=50'-0" FS1.1

COMPONENT SCHEDULE: SECTION C-C SCALE: 1 2"=1'-0" SENSING LINE DETAIL NOT TO SCALE SECTION B-B SCALE: 1 2"=1'-0" HOUSEKEEPING PAD DETAIL NOT TO SCALE FIRE PROTECTION DETAILS FIRE PROTECTION ROOM PLAN DETAIL SCALE: 1 2"=1'-0" FS1.2

UNDERFLOOR PLUMBING PLAN P101

ROOF PLUMBING PLAN P102

SA-C SA-B LARGE SCALE PLUMBING PLANS AND SCHEMES P401

PLUMBING DETAILS P501

Gas/Oil/Sand Interceptor (MDC Trap) Piping Detail Not to scale DETAILS P502

PLUMBING SCHEDULES, NOTES AND LEGENDS P601

MECHANICAL FLOOR PLAN M101

DETAILS M501

DETAILS M502

SCHEDULES M601

CONTROL FLOOR PLANS AND DETAILS ME101

TEMPERATURE CONTROLS ME201

S S S S S SS S S S PIR S W W PIR W PIR PIR S W PIR C S S SS SS S S S PIR C S S SS S S W PIR S S W PIR S S MAIN AND MEZZANINE FLOOR PLAN LIGHTING E101

MAIN AND MEZZANINE FLOOR PLANS POWER E102

FREEZER, COOLER PLAN AND TEMPURATURE MONITORING PANEL E501

REFRIGERATION ELECTRICAL DETAILS E502

MAIN PANEL "M" PANELBOARD SCHEDULES AND POWER ONE-LINE DIAGRAM E601

FIXTURE SCHEDULE NOTES: 1. SEE SHEET SE5.1 FOR POLE BASE DETAIL. 2. SEE SHEET SE1.5FOR POLE LOCATIONS AND CIRCUITING. 3. BASE SHALL BE HINGED. 4. ORIENT BASE SO POLE MAY BE LOWERED WITHOUT HITTING ANY OBSTRUCTIONS. 5. SEE SPECIFICATIONS 265600 FOR FIXTURE AND POLE FINISH AND COLOR. 6. THE FIXTURE DESCRIPTION AND SPECIFICATIONS TAKES PRECEDENCE OVER CATALOG NUMBER. 7. ALL LED FIXTURES SHALL BE LISTED BY THE DESIGN LIGHTS CONSORTIUM OR BE ENERGY STAR LABELED. LED'S SHALL HAVE A MINIMUM 70LM/WATT EFFICIENCY AND A 5 YEAR WARRANTED LIFE. 8. REFER TO SPECIFICATIONS FOR FLUORESCENT BALLAST REQUIREMENTS. 9. SEE SHEET E101 FOR LIGHT FIXTURES WITH EMERGENCY BATTERY BALLASTS. SCHEDULES SNOW MELT SYSTEM BOILER PUMP - REQUIRES A DISCONNECT, STARTER AND CONTROL MODULE FOR ALTERNATING PUMP ACTIVATION ON INTERMITTENT SCHEDULE. ADD FINAL SELECTIONS TO SCHEDULES E602

FLOOR PLAN INTRUSION DETECT AND ACCESS CONTROL EY101

MAIN AND MEZZANINE FLOOR PLAN FIRE DETECTION AND ALARM FA101