IBS IP CDIO/R 24-8 IBS IP CDIO/R 24-8/SF

Similar documents
IB ST (ZF) 24 PT 100 4/4

IB IL TEMP 2 UTH. Function. INTERBUS Inline Terminal With Two Analog Input Channels for Measuring Temperature. Data Sheet 5722B

IB IL AO 1/U/SF. Function. INTERBUS Inline Terminal With One Analog Voltage Output. Data Sheet 5736CC01

This data sheet is only valid in association with the IL SYS INST UM E user manual.

IB IL AI 2/SF. Function. INTERBUS Inline Terminal With Two Analog Input Channels. Data Sheet 5564A

IB IL 24 PWR IN/PS IB IL 24 PWR IN/PS-PAC

PHOENIX CONTACT - 03/2007

IB IL AI 8/IS IB IL AI 8/IS-PAC

PHOENIX CONTACT - 01/2007

OUTPUT 5/24 VDC PWM/PT 2 CHANNEL. 1 Description. GFK-2761 May 2012

VARIO RTD 2. Function. I/O Extension Module With Two Analog Input Channels for the Connection of Temperature Shunts (RTD) User Manual

IB IL 24/230 DOR 4/W-PC IB IL 24/230 DOR 4/W-PC-PAC

VersaPoint I/O Module

For Immediate Delivery call KMParts.com at (866)

TRIO-PS/1AC/24DC/ 5. Extract from the online catalog. Order No.:

QUINT-PS/ 3AC/24DC/10

PHOENIX CONTACT

QUINT-PS AC/24DC/40

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

QUINT-PS/ 3AC/24DC/40

QUINT-PS-24DC/24DC/10

PHOENIX CONTACT - 06/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

MINI-PS AC/24DC/1.3

QUINT-PS/ 1AC/24DC/20

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

Smart Power Relay E I...

MINI-PS AC/2X15DC/1

VersaPoint I/O Module

6ES7214-1AG31-0XB0. General information Engineering with. Supply voltage 24 V DC Yes permissible range, upper limit (DC)

IB IL TEMP 2 RTD (-PAC)

Type CP-S, CP-C & CP-A Switch mode

CP-T range Product group picture

PHOENIX CONTACT - 05/2008. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 400VAC

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 320VAC 360VAC 400VAC 400VAC

NI REM Remote I/O Overview DATASHEET. Temperature Input Module for Remote I/O

PHOENIX CONTACT

CP-T range Benefits and advantages

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

IB IL 400 ELR 1-3A. Product Description. INTERBUS Inline Power-Level Terminal as a Direct Starter for a Motor With a Power of up to 1.

Digital electronic module 4DO DC24V/2A HF (6ES7132-4BD30-0AB0) SIMATIC

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC

7.2 DV1311.L08 and DV1311.L12

C B. Models. Models 2MOPP

EFX IO84 Input/Output Module

TRIO-PS-2G/1AC/24DC/5

onlinecomponents.com

Subject to changes 11/2003 Page 1/7

UNO-PS/1AC/24DC/150W. Primary-switched power supply unit. Data sheet. 1 Description

Original operating instructions Fail-safe inductive sensor GM504S / / 2010

NOVOHALL Rotary Sensor non-contacting. Series RSC2800 analog

SIMEAS-T. Operating Instructions Transducer without auxiliary power. 7KG6111 and 7KG6101. Operating Instructions

DSR120 Series. xxx Series. 120 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details

Medium Converter FL MC 10BASE-T/FO G850

Switching power supplies CP range, Linear power supplies CP-L range. Content

70 Watt Switching Medical Grade Switching Power Supply with Active PFC CONTENTS 1. GENERAL CIRCUIT TOPOLOGY...2

Passive Current Transducers for Sinusoidal Alternate Currents From A/0...5 A MCR-SLP-1/5-UI-0(-SW)

Cable transducer Analog output / redundant Measuring length absolute up to 5 m

Incremental encoders With blind or through hollow shaft pulses per revolution programmable

ICAM. Electronics & Software. Industrial Charge Amplifier for Applications in Manufacturing. Type 5073A...

Electronic Circuit Breaker with reset input ESS20-1..

CP-E range Benefits and advantages

POINTAX 6000L2 Point Recorder

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800)

18V 35V 65V 40A 60A 1.5W 1.2W ms 40ms. 20ms 20ms

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Transformers, Power Supply Units and Socket Outlets

Power supply CP-D 24/1.3

SIMATIC S7-1200, CPU 1212C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 8 DI 24V DC; 6 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC

Incremental encoders With blind or through hollow shaft pulses per revolution programmable

Absolute encoders - SSI

ATS01N206QN soft starter for asynchronous motor - ATS01-6 A V KW

Proportional amplifier type EV22K5

Power supply CP-D 24/4.2 Primary switch mode power supply

Current / residual current and voltage transformers. Current / residual current and voltage transformers

NEW Series STH Output to 75A, 600 Vac High Industrial Performance (HIPpak) Solid-State Relays

An RS485 bus is used for command, monitoring and diagnostic information that can be supplied to a system controller.

EMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description.

TPP 40 Series, 40 Watt. Order code Output voltage Output current max. Efficiency. max. screw terminal pin connector Vout 1 Vout 2 Vout 3

X20(c)AI General information. 2 Coated modules. 3 Order data. X20(c)AI4622

STEP-UPS/24DC/24DC/3. Uninterruptible power supply. Data sheet. 1 Description. Features

XIOC technology and networking modules

MCR-VAC-UI-0-DC. Voltage transducer for AC voltages. INTERFACE Data sheet _en_02. 1 Description

Features. Regulated Converter. RAC02-SE/277/W 2 Watt Single Output. RAC02- SE/277/W Wired. AC/DC Converter

Industrial PSU with universal input voltage range ( VAC line to line) and configurable output voltage. North America

Power supply CP-E 24/2.5

* Short-circuit detection at On pushbutton. Applications. Indication. S M6801_a S11 A3 S12 S21 S23 S22 S (+)

ATSU01N232LT soft starter for asynchronous motor - ATSU01-32 A V KW

Power supply CP-D 12/2.1

Note1: Efficiency is tested at nominal input and full load at +25 C ambient Note2: Max Cap Load is tested at nominal input and full resisitive load

These power supplies are ideal for medical, telecom, datacom, industrial equipment and other applications.

02/11/2015

Power supply CP-E 24/20.0

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Direct Operated Proportional DC Valve Series D1FP

Protection components

ATS01N222LU soft starter for asynchronous motor - ATS01-22 A V KW

ATSU01N222LT soft starter for asynchronous motor - ATSU01-22 A V KW

General. Environmental. EMC & Safety

Amphenol. Circular. Connectors C 16-1 / C Circular Connectors. Amphenol-Tuchel Electronics

Transcription:

IBS IP CDIO/R 24-8 IBS IP CDIO/R 24-8/SF Data Sheet INTERBUS Digital I/O Module for Use on Robots Revision C1 05/2000 Product Description The modules are designed as compact I/O units for use on robots. In the automotive industry in particular, they can be mounted directly on the welding transformer using Kempf terminal boxes. Features - IP 65 protection - Actuators and sensors are connected using 5-pos. female connectors - Electrical isolation of I/O and bus logic - Power supply for the bus logic and actuators provided via the hybrid cable Operation of both female connectors of one female connector pair (pairs: female connector 1 and 2, 3 and 4, 5 and 6 or 7and8): Ensure that there is a signal either at both female connectors only at pin 2 or at both female connectors only at pin 4. The simultaneous use of pin 2 and pin 4 is not permitted, as it may lead to incorrect signals. Use of pin 2 and pin 4 of one female connector: Ensure that the second female connector of the pair (pairs: female connector 1 and 2, 3 and 4, 5 and 6 or 7 and 8) remains unused. When using pin 2 and pin 4 of a female connector, the operation of the second female connector is not permitted, as it may lead to incorrect signals. 522A0001 Figure 1: IBS IP CDIO/R 24-8... 1

The IBS IP CDIO/R 24-8/SF module is a version of IBS IP CDIO/R 24-8 module. Differences are indicated in the data sheet. IBS IP CDIO/R 24-8 and IBS IP CDIO/R 24-8/SF modules are designed for use in a special installation remote bus in which the power supply for the module electronics and the actuators is carried as well as two wire pairs for additional signals. In the special application on a welding robot, these are signals CCR and SCM. The power supply for the bus logic (24 V DC) and for the actuators (24 V DC) is supplied to the robot controller in the hybrid cable and carried to the modules. 4 A J A > K I " 8, + CE?IKFF O + + 4 5 + 5 A I H 2 H JA? JEL A? = F " 8, + =? J K = J H I K F F O 5 A I H I =? J K = J H I 7 * ) 4 + 4 -, 7 5 $ 5 A I H I =? J K = J H I 5 A I H I =? J K = J H I 7 * ) 4 + 4 -, 7 5 $ 5 A I H I =? J K = J H I 4 > J? J H A H 0 O > HE@? = > A H A J A > K I > H =? D M E J D I K F F O B H > K I C E? = @ =? J K = J H I = I M A = I JM M EHA F = EHI B H = @ @ J E = I E C = I! "! " 4 A J A > K I " 8, + CE?IKFF O " 8, + =? J K = J H I K F F O 1* 5 12 +, 1 4 " 5. 1* 5 12 +, 1 4 " 4 > J? J H A H Figure 2: Electrical installation example for the IBS IP CDIO/R 24-8/SF module Both modules can only be operated using a controller board with Generation 4.x firmware. Cover unused female connectors with a protective cap to ensure IP 65 protection. 2

Connector Pin Assignment K J C E C E I J = = J E 1? E C E I J= = JE H A J A > K I H A J A > K I,,, 1 ' O A M C H A A C H = O ',,, 1, 1 F E, 1 K J C E C E I J = = J + E > H M + 1? E C E I J= = JE HA JA > K I HA JA > K I = A? A? J H HA I A HL A @ $ M D E J A $ HA I A HL A @. A = A? A? J H " 8 7 5" HA @ " " 8 7 5! 8 7 5 $ > K A 8 7 5 $!! ' " 8 7 5! > H M! " 8 7 5 ' "! " " $ 8 7 5 > =? 8 7 5 $ " + + 4 > K A + + 4 ) I I A > O I E@ A + + 4 HA @ + + 4 ) I I A > O I E@ A 5 +! > =?! 5 + 5 + " F K H F A " 5 + 2 - O A M C H A A 2-4 * 5 6 HA I A HL A @ 7 $ $ HA I A HL A @ 2 =? A I DEA @ E C E? A? J H 2 =? A I DEA @ E C E? A? J H 6 DEI K F A H A A @ O= > AJE D A HIA1 * HJA 5 @@ EB A L E? A B M I + + 4 + I J = J? K H H A J H A C K = J E 5 + 5 A? @ = H O? EH? K EJ EJ H E C " Figure 3: Connector pin assignment for the hybrid cable - Do not mix up the terminals, as this may damage the electronics. - Place the individual braided shields together and ensure the shield is fitted according to the manufacturers instructions. Mounting the Installation Remote Bus 2 H J A? J EL A? = F B H I A I H =? J K = J H? A? J H I K J C E C E I J = = J E HA JA > K I 1? E C E I J = = J E HA JA > K I ) Figure 4: Mounting the connecting cables 3

Connection of Inputs and Outputs The I/O from each two channel connector is wired together in an X shape (see Figure 5). This means that there are two inputs/outputs available at one female connector. The input/output signal of the affected channels is available at pin 4, the signal of the corresponding channel is at pin 2. If pin 2 is used (sensor or actuator with two signals), only one female connector may be connected per pair of channels. The corresponding female connector must remain unused and should be covered.. A = A? A? J. H A = A? A? J H! " " 1 JA H =!, 1, 8 " 8 8 " 8, 1, 1 EJE= J HI? A JI! = @ 1 EJE= J HI? A JI " $ = @ )! Figure 5: Channel pair Table 1: Location and pin assignment of sensor/actuator sockets + A? J E K > A H = @ F I EJ E! " $ 5 A I H H =? J K = J H M EJD I EC = IM EJD I EC = 1 F K J K J F K 5J K F F O 1 F K J K J F K J 2 E " 8, + " 8, + " 8, + " 8, + " 8, + " 8, + " 8, + " 2 E! 8 8 8 8 8 8 8 8 2 E 2 E " 2 E 2 I EJE B JDA? LAHA@? A? J H M DA 2 E EI K I A @ 1 7 6 1 7 6 1 7 6 1 7 6 1 7 6 * EJ * EJ * EJ * EJ! * EJ" 1 7 6 1 7 6 * EJ * EJ 1 7 6 1 7 6 1 7 6 1 7 6 * EJ! * EJ * EJ * EJ" 1 7 6 1 7 6 * EJ * EJ$ 1 7 6 * EJ 1 7 6 1 7 6 * EJ * EJ$ ) $ * In the IBS IP CDIO/R 24-8 module, channel 8 can be used in the same way as the other channels. In the IBS IP CDIO/R 24-8/SF module, channel 8 is used only as an input and is permanently connected to the terminal block on the back of the module. It cannot be used as an additional input nor as an output. This also means that there is no output signal at pin 2 of channel 7. Depending on the connector pin assignment, only the output or the input can be used for each channel. 4

Additional Signals On the IBS IP CDIO/R 24-8/SF module, additional signals can be carried from the back of the module via spring-clamp terminals. For the special application on a welding robot, this involves the following signals: - Temperature of the welding transformer Permanently connected to input 8 - Signal for constant current regulation (CCR) Looped directly into the hybrid cable - Signal for secondary circuit monitoring (SCM) Looped directly into the hybrid cable Signal CCR is used to control the welding current. It is passed on to the welding controller by the welding transformer. The input for the thermostatic switch is permanently connected to input 8.! E "!! E Figure 6: Terminal block on the back of the module Table 2: Terminal assignment for the terminal block Terminal Signal 1 Initiator supply U INI 2 IN 8 3 GND 4 Constant current regulation 1 (CCR1) 5 Constant current regulation 2 (CCR2) 6 Secondary circuit monitoring 1 (SCM1) 7 Secondary circuit monitoring 2 (SCM2) In the IBS IP CDIO/R 24-8 module, this terminal block is not provided and signals CCR and SCM are looped through from the incoming to the outgoing remote bus. 5

Programming Data Table 3: The most important data for programmers ID code 3 dec (03 hex ) Length code Input address area Output address area PCP address area Register length on the bus 81 hex 1 byte 1 byte 0 bytes 1 byte Housing Dimensions 54 mm (2.13 in.) 33 mm (1.30 in.) 18,5 mm (0.73 in.) 48 mm (1.89 in.) 3 mm (0.19 in.) 13 mm (0.51 in.) UL BA RC RD E US2 7 8 5 6 3 4 1 2 73 mm (2.87 in.) 150 mm (5.91 in.) 4,5 mm (0.18 in.) 8 mm (0.31 in.) 87 mm (3.42 in.) 22 mm (0.87 in.) 3 mm (0.19 in.) 62 mm (2.44 in.) 20,5 mm (0.81 in.) 14 mm (0.55 in.) 5221A005 Figure 7: Housing dimensions for the IBS IP CDIO/R 24-8/SF module The IBS IP CDIO/R 24-8 module has the same housing dimensions, but does not have an opening and seal on the back. 6

Technical Data General Data Type IBS IP CDIO/R 24-8, IBS IP CDIO/R 24-8/SF Ambient temperature - Operation 0 C to 55 C (32 F to 131 F) - Storage/transport -25 C to 70 C (-13 F to 158 F) Humidity - Operation 75, no condensation - Storage/transport 95, no condensation Degree of protection IP 65, when installed, unused slots should be covered with a protective cap Electrical isolation between - I/O - Bus logic with a test voltage of 500 V AC, 1 min Housing - Dimensions (length x width x height) 150 mm x 54 mm x 48 mm (5.906 in. x 2.126 in. x 1.890 in.) Supply Voltages Bus voltage U S1 Nominal voltage 24 V DC Permissible range 18.5 V DC to 30.5 V DC (ripple included) Ripple 3.6 V pp Current consumption Approximately 120 ma plus initiator current The voltage U S1 is looped through and can be tapped off at the connector for the outgoing remote bus. The maximum continuous current is 4.5 A. Initiator voltage U INI Nominal voltage Current consumption Protection by fuses U S1 minus 1 V 40 ma total current for all inputs (5 ma per input) Electronic overload/ short circuit protection Actuator voltage U S2 Nominal voltage Permissible range Ripple Current consumption 24 V DC 18.5 V DC to 30.5 V DC (ripple included) 3.6 V pp 3.5 A, maximum (IBS IP CDIO/R 24-8/SF) 4.0 A, maximum (IBS IP CDIO/R 24-8) The voltage U S2 is looped through and can be tapped off at the connector for the outgoing remote bus. The maximum continuous current is 7.0 A. INTERBUS Interface Interface type Connection technology Connector pin assignment See Figure 3 Two-wire installation remote bus; Differential signal lines, twisted in pairs IP 65 circular connector 7

Digital Inputs Number of inputs Electrical isolation 7+1 (IBS IP CDIO/R 24-8/SF) 8 (IBS IP CDIO/R 24-8) Yes, for bus logic Test voltage 500 V AC, 50 Hz, 1 min. Input voltage According to DIN 19240 - Permissible range 0 signal -30 V to +5 V - Permissible range 1 signal +13 V to +30 V Input current 5 ma at 24 V, typical Permissible residual current 0 signal 1.5 ma Delay time 0 -> 1 3 ms, typical Delay time 1 -> 0 3 ms, typical Digital Input for Thermostatic Switch (for IBS IP CDIO/R 24-8/SF Only) The digital input for the thermostatic switch of the welding transformer is on the back of the module and can be accessed through the ground plate. It is permanently connected to input 8. Connection method Spring-clamp terminal 0.13-0.5 mm 2 (26-20 AWG) Digital Outputs Number of outputs 8 (IBS IP CDIO/R 24-8) 7 (IBS IP CDIO/R 24-8/SF) Min. output voltage at nominal current U S2 minus 1 V Nominal current per channel 0.5 A electronically short circuit-proof Concurrent channel derating 0.5 Derating All outputs can be on at maximum current without exceeding housing maximum power dissipation. Protective functions Electronic short circuit protection Free running circuit Short circuit current protection < 2 A Limitation of the voltage induced on circuit interruption Approximately -20 V Protection against ground connection interruption Yes Max. leakage current at 0 signal ˆ0.8 ma (according to DIN VDE 19240) Electrical isolation Yes, for bus logic Test voltage 500 V AC, 50 Hz, 1 min. Module Error Messages Short circuit/overload of the initiator supply Short circuit/overload of the output 8

Status and Diagnostic Indicators, E= C I J E? -, I 7 * ) 4 + 4, - 7 5 5 J = J K I -, I 5 J = J K I -, I $ ' Figure 8: Arrangement of LEDs UL BA RC RD E US2 Status Green LED ON: OFF: Green LED ON: OFF: Green LED ON: OFF: Red LED ON: Red LED ON: Green LED ON: OFF: Yellow (red) LED Yellow: Red: Table 4: Diagnostic and status LEDs per remote bus line Module electronics supply voltage Supply voltage present Supply voltage not present - Internal power supply unit for the logic voltage is defective Bus active Data transmission on INTERBUS active No data transmission Remote bus cable check Incoming remote bus cable connected Incoming remote bus cable not connected or defective Remote bus status (Remote Bus Disabled) Outgoing remote bus shut down Group error message short circuit/overload An error occurred - Short circuit/overload on initiator voltage - Short circuit/overload on outputs I/O supply voltage Supply voltage present Supply voltage not present Status per input/output Status per input/output Short circuit/overload of the output 9

EMC Emitted interference according to EN 55011 Class A, industrial area Noise immunity according to - ENV 50140, radiated-noise immunity 10 V/m - ENV 50141, conducted noise immunity 10 V - EN 61000-4-2 (ESD), Criterion 2 6 kv contact discharge - EN 61000-4-4 (Burst), Criterion 2 4 kv (power supply) 2 kv (signal lines) - EN 61000-4-5 (Surge), Criterion 3 0.5 kv symm./asymm. (power supply) 1 kv symm., 2 kv asymm. (signal lines) Mechanical Capability Vibration according to IEC 68-2-6 operation 5 g, Criterion 1 Shock according to IEC 68-2-27 15 g Ordering Data Table 5: Ordering data Description Type Order No. Digital I/O module Digital I/O module IBS IP CDIO/R 24-8/SF IBS IP CDIO/R 24-8 27 19 56 4 27 19 46 7 Protective caps (5 pcs.) for unused sensor/actuator sockets Protective caps for unused outgoing installation remote bus sockets IBS IP PROT IO 27 59 91 9 MSK 2 16 65 90 7 Crimping pliers Crimpfox RC 2.5 12 05 44 8 Remote bus connector: Male connector, straight Female connector, straight Male connector, angled Female connector, angled TGGM/CDIO/17-ST TGGM/CDIO/17-BU TWGM/CDIO/17-ST TWGM/CDIO/17-BU 16 67 89 5 16 67 90 5 16 67 95 0 16 67 96 3 10

11 Table 6: IBM PC IBS PC ISA SC/I-T Assignment of inputs for IBS IP CDIO/R 24-8/SF and IBS IP CDIO/R 24-8 modules to the addresses of various control or computer systems Word access E.g.: W 16 Bit 16.15 16.14 16.13 16.12 16.11 16.10 16.9 16.8 16.7 16.6 16.5 16.4 16.3 16.2 16.1 16.0 Siemens S5 Word access E.g.: IW 16 IBS S5 DSC/I-T Bit 16.15 16.14 16.13 16.12 16.11 16.10 16.9 16.8 16.7 16.6 16.5 16.4 16.3 16.2 16.1 16.0 Byte access E.g.: IB 16 E.g.: IB 17 Bit 16.7 16.6 16.5 16.4 16.3 16.2 16.1 16.0 17.7 17.6 17.5 17.4 17.3 17.2 17.1 17.0 Module Sensor 8 7 6 5 4 3 2 1 This address area is not used. INTERBUS Word E.g.: W16 reference Bit 16.15 16.14 16.13 16.12 16.13 16.10 16.9 16.8 16.7 16.6 16.5 16.4 16.3 16.2 16.1 16.0 Table 7: IBM PC IBS PC ISA SC/I-T Assignment of outputs for IBS IP CDIO/R 24-8/SF(*) and IBS IP CDIO/R 24-8(**) modules to the addresses of various control or computer systems Word access E.g.: W 16 Bit 16.15 16.14 16.13 16.12 16.11 16.10 16.9 16.8 16.7 16.6 16.5 16.4 16.3 16.2 16.1 16.0 Siemens S5 Word access E.g.: QW 16 IBS S5 DSC/I-T Bit 16.15 16.14 16.13 16.12 16.11 16.10 16.9 16.8 16.7 16.6 16.5 16.4 16.3 16.2 16.1 16.0 Byte access E.g.: QB 16 E.g.: QB 17 Bit 16.7 16.6 16.5 16.4 16.3 16.2 16.1 16.0 17.7 17.6 17.5 17.4 17.3 17.2 17.1 17.0 Module Actuator -*/8** 7 6 5 4 3 2 1 This address area is not used. INTERBUS Word E.g.: W16 reference Bit 16.15 16.14 16.13 16.12 16.13 16.10 16.9 16.8 16.7 16.6 16.5 16.4 16.3 16.2 16.1 16.0

When several modules are used in combination with one of the above controller boards, the addresses of two or more modules can be combined in one word per data direction. This avoids gaps in the address area of the control or computer system. Addressing by the user (user-defined combination) and default addressing by the control system (automatic combination) have to be differentiated: User-Defined Combination of Module Address Areas: You can set the address area or parts of the address area of a module to any address of the control or computer system. Byte limits must not be exceeded. Modules can be distributed anywhere in the INTERBUS ring. Automatic Combination of the Address Areas of Modules in One Word (Automatic Filling of Words) With the Generation 4 Firmware: When combining automatically, the firmware groups together the address areas of consecutive modules with the same data direction according to the following principles: - Two consecutive modules on the INTERBUS ring with up to four bits are grouped together in one byte. The first module occupies the lower bits of the byte, the second module occupies the higher bits. In a word the higher byte is occupied first. - Each byte module occupies a new byte address. The higher byte is occupied first (see Tables 6 and 7). - Each word module occupies a new word address. Phoenix Contact 01/2000 TNR 94 08 49 6 12