Series 10-ZSE80/10-ISE80

Similar documents
Series 10-ZSE30A(F)/10-ISE30A

Electronic Vacuum Regulator. Standard Specifications. Model Voltage

Electronic Vacuum Regulator. How to Order ITV S 5. Monitor output

Though the size is compact, the measurement display uses 4 digit, 8 mm in letter height, red 7-segment LEDs. Letter height 8mm (0.

GC83 Digital Indicators & GC93 Digital Meter Relay

Correction Reissue. Product Discontinuation Notices

How to Order Manifold. Manifold mounting. DIN rail mounting style Direct mounting style

High Accuracy Eddy Current Type Displacement Sensor GP-A SERIES. Resolution 0.04 % F.S., Linearity ±0.5 % F.S., IP67G environment resistance

Non-Submersible Industrial Pressure Transducer

Digital flow transmitter for continuous flow measurement

0.01kV (0 to ±0.99 kv)

High Accuracy Eddy Current Type Displacement Sensor GP-A SERIES. Resolution 0.04 % F.S., Linearity ±0.5 % F.S., IP67g environment resistance

Valve Island with Electronic I/O

E8EB-N0C2B E8EB-N0B2B

A new approach to static electricity countermeasures

Optimising controls Vacuum switches

Solid State Pressure Sensors D8M

} Max. Load Resistance : 750Ω when power supply voltage is 24V DC (Max. load resistance (Ω) = 50x Power Supply Voltage -450 ).

E2S World's Smallest Square Sensor with Built-in Amplifier

Multifunction Pulse-to-Pneumatic Converter

MODEL: 47LPA. [2] ALARM OUTPUT 0: None 1: N.O. relay contact, 4 points 2: SPDT relay contact, 2 points. Digital Panel Meters 47 Series

MODEL: 47LV. Digital Panel Meters 47 Series

Dissolved Oxygen Transmitter (For Low-Concentration Measurement) OBM-165H

Pressure Transmitter SIL

PAD - Heavy Duty Differential Pressure Trasmitter

OEM pressure transmitter for general industrial applications Models O-10 (T), O-10 (5)

D7F. Detects Changes in Machine. Vibration. Vibration Sensor with Linear Output or Manual Setting. Ordering Information

ph or ORP Transmitter

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400

Digital flowmeter for continuous flow measurement

Modus M Series. General Eastern Differential Pressure Transmitters. GE Sensing

Application Examples. Features. Ultrasonic Displacement Sensor E4PA-N. Now, more advanced with a new mutual interference prevention function.

Application Examples. Features. Ultrasonic Displacement Sensor E4PA-N. Now, more advanced with a new mutual interference prevention function.

LED Collimated Beam Sensor LA-300 SERIES. LED collimated beam type which is as accurate as a laser sensor, but much safer.

TURCK Inc Campus Drive Minneapolis, MN Application Support: PROX Fax: (763)

ThermoPLUS Smart Temperature Transmitter

CZ-K Series. RGB Digital Fiberoptic Sensors. Description MAIN MENU PRODUCTS APPLICATIONS INDEX SELECTION GUIDE

Most Suitable for a Variety of High-precision Displacement Measurements. Regular Reflective Sensors. Line Beam Sensors.

PZ-30 PRESSURE INDICATORS P Z N V S T I FEATURES MODEL NUMBER DESIGNATION LIST OF MODEL NUMBERS

PRESSURE SENSORS I INSTALATION AND OPERATION INSTRUCTIONS ACCUTRON MDP BIDIRECTIONAL DIFFERENTIAL PRESSURE SENSOR

LED Collimated Beam Sensor LA-300 SERIES. LED collimated beam type which is as accurate as a laser sensor, but much safer.

Cylindrical type proximity sensor

Digital flowmeter for continuous flow measurement

Inductive Proximity Sensor

Self-Powered Counters H7ET

INSTRUCTION MANUAL SMART POSITIONER ESL & ESR SERIES. ESL & ESR Series. Installation & Maintenance Manual

Digital Fiber-Optic Switches

ED701 General Industry Pressure Transmitter

Monitoring Relay MR 50

Series T. General Eastern Differential Pressure Transmitters. GE Sensing. Description

Digital batch controller

Ionizer. Potential amplitude: 25 V or less Rapid neutralization of static electricity: Fastest time: 0.1 seconds. Series IZS40/41/42.

Conductivity Transmitter

DP2500 DP0100 DP0250 Differential Pressure Transmitter

Ultrasonic level transmitter, non-contact

Model Sono-Trak Transit Time

Sensing method Through-beam Retroreflective Diffuse reflective Convergent-beam Appearance Side-view Flat Side-view Flat Side-view

Assembly 249 (9.80) 259 (10.2) Example: level probe with Pt100 and HUT temperature head transmitter ( ma) ma. Core colors: RD BK YE BU

Series LC8. Positioning Driver/For AC Servomotor. Compliant actuators/series LJ1, Series LG1, Series LTF

Beamex MC2 HAND-HELD CALIBRATOR. Practicality in calibration

FAS 10 mm PICOSOL Direct acting solenoid valve

TL-W. Standard Flat Inductive Proximity Sensors. Ordering Information. Front and side facing surface IP67 DC 2-wire and DC 3-wire models

High Accuracy Positioning Sensors EG Series Features

Ultra-slim Body Picking Sensor NA1-PK5 SERIES NA1-5 SERIES. Even a slim hand is detectable by the 25 mm in pitch beam area sensor

Design and applications

Sensing method Through-beam Retroreflective Diffuse reflective Convergent-beam Appearance Side-view Flat Side-view Flat Side-view

Digital flow ELEMENT transmitter for continuous flow measurement

Connection targets. Universal sensors and switches, universal output devices

High Reliability Of Fiber Optic Amplifier For Convenient Mounting

Operating mode. distance. 7 m Light ON Dark ON (selectable) 2 m [100 mm] (See note 1.) 100 mm (wide view)

Electro-Magnetic Flowmeters COPA-XE

OEM pressure sensor For industrial applications Models O-10 (T), O-10 (5)

High-speed Sub-micron Displacement Sensor with 40,000 Samples/sec. High Accuracy Inductive Gauging Technology

WLL 170 Photoelectric switches with fibre-optic cable, red light, manual sensitivity adjustment -- DC. Dimensional drawing R1.6 2-R

Pressure Transmitter Type AKS 32 and AKS 33 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

LX-100 SERIES Conforming to EMC Directive

Posiflow Proportional Solenoid Valves % ^ ) 2/2. Brass or Stainless Steel Bodies 1/8" to 1/2" NPT. Proportional Valves. Features.

40 mm Beam Pitch General Purpose Area Sensor NA40 SERIES

USA series. Capable of long-distance measurement Built-in teaching function for simple operation and highlyaccurate

M/SSL/SSR/E INSTRUCTION MANUAL SMART VALVE POSITIONER SSL & SSR SERIES

High-quality pressure transmitter For general industrial applications Model S-20

Base Mounted Plug-in Unit

Overview of types. Technical data

RHE11. Hazardous Area Multifunction Coriolis Flow Transmitter. Features. Applications. Benefits

Grundfos Direct Sensor

LX-100 SERIES. Digital Mark Sensor Amplifier Built-in. Introduction of the 3 LED mark sensor 4:1. Can detect any mark!

Series T. Amphenol Advanced Sensors. Differential Pressure Transmitters

Set model No. ESN-T8. 140mm ESN-T mm ESN-T mm ESN-T mm. Light axis interval: 20mm. Smallest detectable object diameter: 30 mm

Adsorption Plate. SP Series. Specialized for adsorption and fixing in place of thin sheets, glass substrates, and soft workpieces.

Beamex MC5-IS INTRINSICALLY SAFE MULTIFUNCTION CALIBRATOR. Made for extreme environments

2 AMP. HIGH CAPACITY RELAY WITH HIGH SURGE VOLTAGE & HIGH BREAKDOWN VOLTAGE FEATURES. Characteristics. Initial breakdown voltage

HG-C SERIES. Micro Laser Distance Sensor. Reliable detection in 10 μm precision. We offer three types of laser sensor heads for various applications

Product Discontinuation Notices

U5700 Submersible Liquid Level Pressure Transducer

Simplified Operations for TM-3100 Series Digital Tachometer

Ultrasonic Displacement Sensor E4DA

+GF+ SIGNET Temperature Transmitter Instructions

Pressure transmitter AKS 32 and AKS 33

FAST SAMPLING CONVERTER

KFS. Flap-type flow meter. Design and range of application

Transcription:

Series 0-ZSE80/0-ISE80 RoHS -Color Display Digital Pressure Switch For General Fluids Directional Control Valves For positive 0 80 For vacuum/ compound 80 80F N P B R T S V Rated range Symbol -X50 Clean series 0 to 0 kpa 00 to 00 kpa 0 Piping R/4 0 (M5 female thread) NPT/4 N0 (M5 female thread) G/4 F0 (M5 female thread) C0 Rc/8 URJ/4 B TSJ/4 Piping direction L (bottom ported) is not available. Specifications Lead wire length 3 m Note) Refer to page 35 for detail. Option Option Piping direction Bracket Panel mount Panel mount Front protection cover Part no. 0-ZS-4-0-ZS-4-D 0-ZS-35-0-ZS-35-C 0-ZS-35-B 0-ZS-35-F 0-ZS-35-E How to Order Rated range 80 0. to MPa 80H 0. to MPa ISE 0 N ZSE 80 0 N Nil Piping direction Piping specification F (G /4) is not available. Input/Output NPN open collector output PNP open collector output NPN open collector outputs PNP open collector outputs NPN open collector outputs nalog voltage output/uto-shift switching PNP open collector outputs nalog voltage output/uto-shift switching NPN open collector outputs nalog current output/uto-shift switching PNP open collector outputs nalog current output/uto-shift switching Table Made to Order Caution This product is the 0-ZSE80/ISE80 series blown with air and double packed in a Class M3.5 (ISO Class 5) clean room. L Nil B C D Option Nil M P M M None With bracket With bracket Note) Panel mount 0-ZS-35-C 0-ZS-4- Panel mount Front protection cover 0-ZS-35-F Note) only With unit switching function Note ) Fixed SI unit Note ) Initial value psi Made to Order Refer to Table below. Option 3 Symbol Nil Y K T Operating Note) manual (Booklet) (Booklet) Calibration certificate Note ) Under the New Measurement Law, sales of switches with the unit switching function are not allowed for use in Japan. Note ) Fixed unit 0-ISE80H : MPa Others : MPa, kpa Option 0-ZS-35-0-ZS-4-D Note) ll texts in both English and Japanese 0-ZS-35-B 0-ZS-35-E 340 Fittings & Tubing Modular F. R. ir Grippers Rotary ctuators ir Cylinders ir Preparation Pressure Control Flow Control Pressure Switches/ Pressure Sensors

Specifications Refer to the SMC website for Pressure Switches Precautions (M-E03-3) and Specific Product Precautions (Operation Manual). Model Rated range Display/Set range Withstand Wetted parts material Display/Smallest settable increment pplicable fluid Power supply voltage Current consumption Switch output Repeatability Hysteresis nalog output uto-shift input Display Display accuracy Indicator light Environment resistance Temperature characteristics Lead wire Maximum load current Maximum load voltage Residual voltage Response time Short circuit protection Standards Cleanliness class (ISO class) Hysteresis mode Window comparator mode Output voltage Voltage (Rated range) output Linearity Output impedance Output current (Rated range) Current Linearity output impedance Enclosure Operating temperature range Operating humidity range Withstand voltage Insulation resistance 0-ZSE80 (Vacuum ) 0-ISE80 (Positive ) 0.00 to.000 MPa 0.05 to.00 MPa MPa 0.0 to 0.0 kpa 00.0 to 00.0 kpa 0.00 to.00 MPa 0.0 to. kpa 0.0 to 0.0 kpa 0.05 to. MPa 500 kpa 4 MPa Pressure sensor: Stainless steel 630, Fitting: Stainless steel 304 0.00 MPa (to.999) 0. kpa 0. kpa 0.00 MPa 0.0 MPa (.00 to) Fluids do not corrode stainless steel 630 and 304 to ±0%, Ripple (p-p) 0% or less (with power supply polarity protection) 45 m or less NPN output, NPN outputs, PNP output, PNP outputs 80 m 8 V (at NPN output) V or less (with load current of 80 m).5 ms (with anti-chattering function:, 00, 500, 000, 00 ms) Yes ±0.% F.S. ± digit to 5 V ±.5% F.S. 0-ZSE80F (Compound ) Variable (0 or above) ±% F.S. or less pprox. kω.4 to m 3. to m 4 to m ±.5% F.S. ±.5% F.S. ±.5% F.S. ±% F.S. or less Maximum load impedance: 300 Ω (Power supply voltage V) 600 Ω (Power supply voltage 4 V) Minimum load impedance: 50 Ω Non-voltage input (Reed or Solid state), Low level: 0.4 V or less, 5 ms or longer input 3 /-digit, 7-segment, -color LCD (Red/Green) ±% F.S. ± digit (mbient temperature of 5 ±3 C) Lights up when output is turned ON. OUT, OUT: Orange IP65 Operating: 0 to 50 C, Stored: 0 to 60 C (No freezing or condensation) Operating/Stored: 35 to 85% RH (No condensation) 50 VC for minute between live parts and case MΩ or more between live parts and case (at 50 VDC Mega) ±3% F.S. (Based on 5 C, within operating temperature range) Oilproof heavy-duty vinyl cable, 3 cores (N.P) 4 cores (.B) 5 cores (R.T.S.V) CE UL/CS (E6656) RoHS Class 4 0-ISE80H (Positive ) 0.6 to 5 V ±.5% F.S. 0.8 to 5 V ±.5% F.S. ø3.5, m Conductor area: 0.5 mm (WG6) Insulator O.D.: 0.95 mm Piping Specifications Model Port size Weight () Weight () Leakage 0 R/4 7 g 89 g N0 NPT/4 F0 G/4 C0 Rc/8 URJ/4 B TSJ/4 8 g 4 g g g 90 g 86 g 86 g 9 g 83 g x 0 5 Pa m 3 /s x 0 0 Pa m 3 /s 34

Set Pressure Range and Rated Pressure Range Set the within the rated range. The set range is the range of that is possible in setting. The rated range is the range of that satisfies the specifications (accuracy, linearity, etc.) on the switch. lthough it is possible to set a value outside the rated range, the specifications will not be guaranteed even if the value stays within the set range. Directional Control Valves For vacuum For compound For positive nalog Output Voltage output nalog output [V] 5 Switch 0.6 B 0-ZSE80 0-ZSE80F 0-ISE80 0-ISE80H C 0 kpa kpa 0 kpa 00 kpa 0. MPa Pressure Pressure range 00 kpa 0 00 kpa MPa MPa Current output nalog output [m] 4.4 B 0 0 kpa C Range For vacuum For compound For positive Pressure 00 kpa 0 kpa Rated range 0.0 to 0.0 kpa MPa 0.05 MPa. MPa 0. MPa 0.05 MPa 0. kpa B 0 C 0.0 kpa 00.0 to 00.0 kpa 00.0 kpa 00.0 kpa 0.00 to.000 MPa 0.00 MPa 0.000 MPa 0.00 to.00 MPa 0.00 MPa Note) 0.00 MPa Note) nalog output is 0.8 [V] or 3. [m] at the. MPa. MPa Rated range of switch Set range of switch ir Preparation Flow Control Pressure Control Fittings & Tubing Modular F. R. ir Grippers Rotary ctuators ir Cylinders 34 Pressure Switches/ Pressure Sensors

U U Internal Circuit and Wiring Example -N NPN ( outputs) -P PNP ( outputs) Main circuit Black OUT to Main circuit Black OUT to Blue DC () Blue DC () Max. 8 V, 80 m Residual voltage V or less Max. 80 m Residual voltage V or less - NPN ( outputs) -B PNP ( outputs) Main circuit Main circuit Max. 8 V, 80 m Residual voltage V or less Main circuit Black OUT White OUT Blue DC () -R, -S R: NPN ( outputs) nalog voltage output S: NPN ( outputs) nalog current output Max. 8 V, 80 m Residual voltage V or less Gray nalog output Black OUT White OUT Blue DC () -T, -V T: PNP ( outputs) nalog voltage output V: PNP ( outputs) nalog current output Gray nalog output Black OUT White OUT to to to Main circuit Max. 80 m Residual voltage V or less Main circuit Main circuit Black OUT White OUT Blue DC () -R/-S NPN ( outputs) uto-shift input Max. 8 V, 80 m Residual voltage V or less Gray uto-shift input Black OUT White OUT Blue DC () -T/-V PNP ( outputs) uto-shift input Gray uto-shift input Black OUT White OUT to to to Blue DC () Blue DC () Max. 80 m Residual voltage V or less 343 Max. 80 m Residual voltage V or less

Dimensions (For details about lead wires, refer to the product specifications.) 0-ZSE80/0-ISE80-0 N0 F0 C0 B 30 6. 49.6 (N0: 50.) 8.5 M5 x 0.8 thread depth 5 Directional Control Valves 30 0 8.8 tmospheric vent port ø.6 6. ø3.5 46. 8.5 4.7 Rc/8 -C0: Rc/8 7.7 0: R/4 N0: NPT/4 x M3 x 0.5 thread depth 4 When the switch is used in a place where water and dust splashes may occur, insert a tube into the atmospheric vent port, and route the other end of the tube to a safe place away from water and dust. SMC TU045 (polyurethane, O.D. ø4, I.D. ø.5) suits to the switch. Note) If it is predicted that the, such as the water hammer or surge fluctuates rapidly, refer to the Handling Precautions stated in the Operation Manual at SMC website (http://www.smcworld.com). 45. 6. 8.5 G/4 -F0: G/4.7 7 M5 x 0.8 thread depth 5 Width across flats 7 Fittings & Tubing Modular F. R. ir Grippers Rotary ctuators ir Cylinders ir Preparation Pressure Control URJ/4 TSJ/4 Flow Control -: URJ/4 -B: TSJ/4 344 Pressure Switches/ Pressure Sensors

Dimensions (For details about lead wires, refer to the product specifications.) 0-ZSE80/0-ISE80-0L N0L C0L L BL 30 4 5. 0 30 60.5 (N0L: 6.5) x M3 x 0.5 thread depth 4 ø3.5 0L: R/4 N0L: NPT/4 8.8 tmospheric vent port ø.6 0.3 M5 x 0.8 thread depth 5 Width across flats 7 9.5 5. 4 49.5 When the switch is used in a place where water and dust splashes may occur, insert a tube into the atmospheric vent port, and route the other end of the tube to a safe place away from water and dust. SMC TU045 (polyurethane, O.D. ø4, I.D. ø.5) suits to the switch. Note) If it is predicted that the, such as the water hammer or surge fluctuates rapidly, refer to the Handling Precautions stated in the Operation Manual at SMC website (http://www.smcworld.com). 64.8 58.8 Rc/8 URJ/4 TSJ/4 -C0L: Rc/8 -L: URJ/4 -BL: TSJ/4 345

Dimensions (For details about lead wires, refer to the product specifications.) With bracket () 0-ZS-4-30 Directional Control Valves 60.5 39.7 43 49 43. 5.5 4.5 43. 5 0.5 4. ø4.5 6.5 View 7. 7.5 5. 55 55 30.6 With bracket () 0-ZS-4-D.6 30 With bracket () 50 40 30 40 40 4 x ø4.5 39.7 4.5 Fittings & Tubing Modular F. R. ir Grippers Rotary ctuators ir Cylinders ir Preparation Pressure Control ø3.5 Flow Control 40.3.5 6.3 35.5 47 346 Pressure Switches/ Pressure Sensors

Dimensions (For details about lead wires, refer to the product specifications.) Panel mount () 40 7.5 5. 56. 36±0.3 36 x n pcs. 4 x (n pcs. ) 36±0.3 36 5. Panel thickness to 5 mm 38.6 Panel-cut dimensions 4 x R3 or less 67 or more 4 x R3 or less 347

Dimensions (For details about lead wires, refer to the product specifications.) Panel mount () 40 7.5 4. 50 Directional Control Valves 5. Panel-cut dimensions 36±0.3 38.6 36±0.3 Panel thickness to 5 mm 36 36 x n pcs. 4 x (n pcs. ) 4 x R3 or less 4 x R3 or less Flow Control 7. ir Preparation Pressure Control Fittings & Tubing Modular F. R. ir Grippers Rotary ctuators ir Cylinders 348 Pressure Switches/ Pressure Sensors

Function Details uto-shift function (F4) When there are large fluctuations in the supply, the switch may fail to operate correctly. The auto-shift function compensates such supply fluctuations. It measures the at the time of auto-shift signal input and uses it as the reference to correct the set-value on the switch. Set-value correction by auto-shift function (Differential) Pressure Switch output () uto-shift input P- (P-3) H- (H-) ON OFF Hi Lo Supply normal Supply drop Rectified value Supply increase B Switch output 5 ms or more 0 ms or less response time when autoshift is input. Rectified value When the auto-shift is selected, ooo will be displayed for approximately second, and the value at that point will be saved as a rectified value C_5. Based on the saved rectified values, the set-value Note) of P_, H_, P_, and H_ will likewise be rectified. Note) When an output is reversed, n_, H_, n_, H_ will be rectified. Possible Set Range for uto-shift Input Regulating range Compound 0.0 to 0.0 kpa Vacuum 0.0 to.0 kpa 0.05 to.00 MPa Positive 0.05 to. MPa Rectified value Possible set range to kpa.0 to.0 kpa.5 to.5 MPa.3 to.3 MPa uto-shift zero The basic function of auto-shift zero is the same as the function for auto-shift. lso, it corrects values on the display, based on a value of 0, when the auto-shift is selected. B uto-preset function (F8) uto-preset function, when selected in the initial setting, calculates and stores the set-value from the measured. The optimum set-value is determined automatically by repeating vacuum and break with the target workpiece several times. Suction Verification C Precision indicator setting function (F7) Fine adjustment of the indicated value can be made within the range of ±5% of the read value. The scattering of the indicated value can be eliminated. Display value F in brackets stand for the function codes. Refer to the operating manual for how to operate and function codes in detail. High Vacuum Max. P- H- n- Min. B tmosphere ±5% R.D. Suction Work Work Released Work Work Work n Formula for Obtaining the Set-Value P_ or P_ P_ (P_) = (-B)/4 n_ (n_) = B (-B)/4 0 pplied H_ or H_ Work n H_ (H_) = (-B)/ Displayed value at the time of shipment djustable range of display calibration function Note) When the precision indicator setting function is used, the set value may change ± digit. D Peak and bottom display function This function constantly detects and updates the maximum (minimum) value and allows to hold the maximum (minimum) value. When the buttons are simultaneously pressed for second or longer, while holding, the hold value will be reset. E Key lock function This function prevents incorrect operations such as accidentally changing the set-value. F Zero-out function This function clears and resets the zero value on the display of measured. For the switch with analog output, the analog output shifts according to the indication. displayed value can be adjusted within ±0% F.S. of the when ex-factory. 349

Function Details G Error indication function Error name Overcurrent error Residual error pplied error uto-shift error System error Error code H nti-chattering function (F3) large bore cylinder or ejector consumes a large volume of air in operation and may experience a temporary drop in the supply. This function prevents detection of such temporary drops in the supply as an error. <Principle> This function averages values measured during the response time set by the user and then compares the average value with the set point value to output the result on the switch. Pressure Pressure range P- H- Internal data error Internal data error Internal data error Description current of switch output (OUT) exceeds 80 m. current of switch output (OUT) exceeds 80 m. It is still applied with that is ±0% over the atmospheric and the upper limit of the rated range when it is cleared to zero. fter displaying the error code for second, the switch automatically returns to the measuring mode. Due to individual product differences, the setting range varies ± digits. Supply exceeds the maximum set. Supply is below the minimum set. The value measured at the time of auto-shift input is outside the set range. fter displaying the error code for one second, the switch returns to the measuring mode. vailable response time settings ms, 00 ms, 500 ms, 000 ms, 00 ms Momentary change I Display unit switching function (F0) Display units can be switched with this function. Pressure range pplicable sensor Set range kpa MPa kgf/cm bar psi inhg For compound 0-ZSE80F 0-ZSE80 0 to 0 kpa 0. 0.00 0.00 0.00 0.0 0. For vacuum 0 to kpa 0. 0.00 0.00 0.00 0.0 0. mmhg 0-ISE80H: Does not indicate the last digit when the is.000 MPa or higher. K Secret code setting (F0) For positive 0-ISE80 0. to. MPa 0.00 0.0 0.0 0. 0-ISE80H 0. to. MPa 0.00 0.0 0.0 J Power-saving mode (F9) OUT The numerical value disappears and the OUT decimal points blink. Power-saving mode can be selected. It shifts to the power-saving mode without button operation for 30 seconds. It is set to the normal mode (Power-saving mode is OFF.) when ex-factory. (Decimal points and operation indicator light (only when the switch output is turned ON.) blink in the power-saving mode.) OUT OUT Input an arbitrary three-digit value. The set-value can be confirmed when the key is locked. It can be set whether code number input is required or not when key is locked. It is set to input no code number when ex-factory. Directional Control Valves Fittings & Tubing Modular F. R. ir Grippers Rotary ctuators ir Cylinders ir Preparation Pressure Control Switch output operation in normal conditions ON OFF Switch output operation when ON anti-chattering function is on. OFF t (ms) t (ms) Time <veraging> <veraging> Time Time 350 Flow Control Pressure Switches/ Pressure Sensors

Series 0-ZSE80/0-ISE80 Made to Order Please contact SMC for detailed dimensions, specifications, and lead times. Lead wire length 3 m Symbol -X50 It has a lead wire extended to 3 meters. How to Order 0-ZSE80(F)/0-ISE80(H) Piping Output Option Refer to How to Order on page 340 for standard specifications. X50 35