Bidder : M/s Arya Communications Pvt. Ltd., Mumbai.

Similar documents
Bid #3990DB - Two Way Motorola Radio System District Wide Upgrade

United Nations Development Programme

8 th April 2018 ADDENDUM NO. 1

Battery) and all accessories & DTMF Keypad. 4. Spare High capacity batteries 2000 mah and above Li-on / Liion

DCC Trunked Radio System Proposer Questions and Answers, rev 2 September 28, 2011

Hytera DMR Simulcast System

Hytera DMR Simulcast System

BUTLER COUNTY RADIO RFP RESPONSES TO VENDOR QUESTIONS. Butler County 700 MHz, P25 Public Safety Radio Network Issued July 8, 2016

TECHNICAL SPECIFICATION OF LT SHACKLE BOLT (G. I. BOLT) WITH NUT AND SPRING WASHER

SOLUTIONS Paper Wi4 Fixed: Point-to-Point Wireless Broadband Solutions. Point-to-Point Connectivity in the 4.9 GHz Public Safety Band

PURCHASE DIVISION DEPARTMENT QUALITY MANUAL Revision No. : 02 Issue No: : 2 Dt of Revision : Issue Dt. :

APPENDIX H PRICE WORKSHEETS, REVISED 12/26/15 1. BATTERIES, MODULAR FLOODED LEAD-ACID 2. BATTERIES, MODULAR VALVE REGULATED LEAD ACID

Ernie B. McNeely, Township Manager Michael J. McGrath, Superintendent of Police Lower Merion Township Radio System Replacement DATE: June 25, 2014

To be completed by the Bidder. Sl.No. Parameters CPRI Specification / Requirements Qty

Tender NO. PGVCL/PROC/Cable & Pipeline Locator/832

The Corporation of the City of Nelson Office of the Finance and Purchasing Manager Telephone : (250) Fax : (250)

CSP DIGITAL TRUNKED AND RADIO SYSTEM QUESTION AND ANSWERS UPDATED 7/30/2018

INVITATION FOR QUOTATION. TEQIP-II/2017/btec/Shopping/2

DMR Trunking Pro. Hytera Open Standard DMR Trunking Portfolio

ATLAS. P25 Systems. LMR communications made simple.

ANNEXURE-I. Documents to be uploaded 1 Certificate of Registration with Industries 2 VAT Certificate 3 Service Tax Certificate

The attached information contains mandatory requirements and a submission form.

Raveon Technologies Corporation iot.raveon.com

25 CORE ASTRO FLEXIBLE, SCALABLE CONFIGURATIONS

SUPPLY OF CARRIER PROTECTION COUPLER TYPE NSD-50

TEST REPORT FROM RFI GLOBAL SERVICES LTD

INVITATION FOR QUOTATION. TEQIP-II/2013/UP1G01/Shopping/28

Corrigenum SUPPLY & INSTALLATION OF SMART METERS (SINGLE PHASE, THREE PHASE WC, LT CT, HT, AND DT) IN BRPL, NEW DELHI, INDIA (CMC/BR/18 19/FK/PG/674)

Radio Technology Overview. January 2011

The SCHNOOR DMR-System

SOLUTION BRIEF ONE POINT WIRELSS SUITE. PTP LINKPlanner: No Surprises Link Planning for PTP 800 Solutions

TECHNICAL SPECIFICATION OF UNIVERSAL TYPE COMBINED THREE PHASE & SINGLE PHASE PORTABLE ELECTRONIC REFERENCE STANDARD METER CAPABLE OF TESTING OF ALL

SECTION - II BID DATA SHEET

Columbia Communications District Request for Information New Radio Communications System

TECHNICAL SPECIFICATION FOR G. I. WIRE (4MM)

SUPPLY & INSTALLATION OF SMART METERS (SINGLE PHASE, THREE PHASE WC, LT-CT, HT, AND DT) IN BYPL, NEW DELHI, INDIA (CMC/BY/18-19/RB/VKS/021)

ABC Company. Greenville, SC VIRTUAL SITE SURVEY REPORT

Pulse Communication Systems Pvt. Ltd. PRODUCT CATALOG

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA MATERIALS MANAGEMENT / CAPITAL EQUIPMENT

Challenging Communication Boundaries. RoIP Gateways. Radio over IP for Optimal Analog & Digital Radio Network Performance

SPECIAL SPECIFICATION 6574 Low Power Wireless Modem

RD62X. Digital Migration Radio. Wall Mount Repeater for Indoor.

R2.9. MOTOTRBO Software Release. Manuel Moreno PCR Product Manager

INDIAN INSTITUTE OF TECHNOLOGY KHARAGPUR , INDIA

Test Report. Prepared for: Technologic Systems, Inc. Model: TS Description: Embedded Computer Board. Serial Number: N/A. FCC Part 15B Class A

NEVADA DEPARTMENT OF TRANSPORTATION Addendum 3 to RFP July 28, 2017

Commercial Systems for PPDR Use - An Example -

SPECIFICATION FOR UHF HANDHELD AND DESKTOP RADIOS FOR SHUNT YARDS

Watertown City Council

ERC/DEC/(99)23 Archive only: ERC/DEC/(99)23 is withdrawn and replaced by ECC/DEC/(04)08. Including the implementation status in the download area

CONCEPTS TO OPERATIONS, INC.

Clark County Fire Prevention Las Vegas Nevada

PART E SPECIFICATIONS

Description of Changes ADDENDUM NO. 7

LICENSING GUIDELINES AND PROCEDURES FOR SHORT-RANGE RADIO SERVICE (SRRS). For the purpose of this Circular, the following terms are defined hereunder:

Public Safety Radio System Request For Proposal. Otsego County, NY. Addendum #2

SOLUTIONS Paper Wi4 Fixed: Point-to-Point Wireless Broadband Solutions. Point-to-Point Connectivity in the 4.9 GHz Public Safety Band

REQUEST FOR INFORMATION: FINSAS SINGLE BAND AND DUAL BAND HANDHELD RADIO SETS (HHRS)

Hytera DMR Trunking Pro

Tait Communications Ltd Master Price List (USD) January 2015 Version 1.15

TCN Ref: PSER:SCT:RKL-M1797:TCN-03 Date:

1. INTEROPERABILITY GATEWAY DEVICES

500 Series AP and SM CAP and CSM Licensed, Reliable Wireless Connectivity

MANAGEMENT COMPLEX / GST:33AAACN1121C1ZG CIN:L93090TN1956GOI /TENDER ENQUIRY NO :ENQ/18-19/003497/MM15(02) /DATE

Professional UHF Rechargeable Wireless Microphone System POWER ON/OFF BATTERY CHARGE. Green Light (Full) Better Music Builder DOWN VOLUME

THE KENYA POWER AND LIGHTING CO. LTD. SPECIFICATIONS for IMPULSE VOLTAGE TEST EQUIPMENT

DMR. PROFESSIONAL DIGITAL MOBILE RADIO Connections that Count

LOCOMOTIVE ENGINEERING DEPTT.

MAGNETIC FIELD METER Operator s Manual

Tender Management System Version 1.0 [ Tender Document ]

SECTION-I (G.I.PLAIN WIRE) TECHNICAL SPECIFICATION FOR G. I. WIRE

ETSI EN V1.1.1 ( )

Fabrication and Supply of Cable Tray. CTI Agartala, Aligarh, Gorakhpur, Muzaffarpur, Patna

32 CHANNEL SELECTABLE CH MHZ DOWN VOLUME

HydroLynx Systems, Inc.

Hytera DS-6210 DMR Trunking Pro

Plant Client Contract Code Document ID Contract No. TECHNICAL SPECIFICATIONS DC SHUNT Rev 00 Page 1 of 2

SI.No Parameters CPRI Specification/Requirements To be Completed by the Bidder Guaranteed Technical

DESIGN PRACTICE NOTE GENERAL OCS SPECIFICATION UPDATE

ELECTRICAL TESTING

SECTION EMERGENCY RESPONDER RADIO COVERAGE SYSTEMS

EMERIS Consistent data communication from the meter right through to the invoicing. Simple, unitised and sustainable.

ECREE OF THE DIRECTOR GENERAL OF POST AND TELECOMMUNICATION NUMBER: 171/DIRJEN/2009

RF Considerations for Wireless Systems Design. Frank Jimenez Manager, Technical Support & Service

SPECIFICATION FOR SAFETY POLE SIGNS & ACCESSORIES

Proposal Evaluation Methodology. For Narrow Band Power Line Carrier Equipment

Panorama Antennas Leaders in Professional Antennas

The RSM shall be extensively used in field & laboratory for verification of the accuracy of all types of single-phase energy meters.

TK-2312E TK-3312E. New Product Release Information. VHF FM Transceiver UHF FM Transceiver. March 2011

Guidelines for communication system of smart meters PLC, RF, cellular network (3G/4G) CENTRAL ELECTRICITY AUTHORITY

Hytera DMR Trunking Lite. Open Standard Smooth Migration Overall Delivery Power Up To Talk.

Solutions ADVANCED SOLUTIONS FOR SMART COMMUNICATIONS. RADIO DISPATCHER FLEET PHONE APP BRIDGE

AW5800-SPEC USER S MANUAL

wireless synchronized time + messaging

Welcome to EnGenius Versatile Wireless Networking Applications and Configurations - Part 1 Outdoor Wireless Networking Products

The world's thinnest & smallest full power digital portable radio

NATIONAL POWER TRAINING INSTITUTE (WR) (Ministry of Power, Govt. of India) NAGPUR TENDER DOCUMENT SUPPLY OF DRAWING TABLES AND STOOLS

Moline Illinois CODE OF ORDINANCES. Art. IX. Miscellaneous DIVISION 3. IN-BUILDING EMERGENCY RADIO SYSTEM COVERAGE

BridgeCom Systems D Centimeter DMR and Analog Handheld Transceiver

RF Exposure evaluation

Transcription:

Bidder : M/s Arya Communications Pvt. Ltd., Mumbai. Tender No. - 1936 Serial No DGP/17/6162/DMR-Navi Mumbai/69/2018 Clarification in Technical Specifications DMR System in UHF 400 Mhz. for Navi Mumbai ( These clarifications are applicable for all the responding bidders ) Sr. No. Tender Reference (Page No/ Clause No) 1 Page No.#15 Section A_Site Details for Installation_Inter- Site Radios (On Tabular Column) Tender Clause Bidder's Observation/Queries Response to Queries/ Clarification 2 Page No.#15 Section A_SRF channel hardware (On Tabular Column) 3 Page No.#16 Proposed DMR Network Diagram of Navi Mumbai Police Commissionarate_Wir eless Link 4 Page No.#18 Static Radios_G. Accessories & Manuals_ 6Db Antenna & Co-Axial cable submission 5 Page No. #19, 22, 26, 30, Warranty Clause for Mobile, Static, Portable, Repeater and Dispatcher Please clarify in details " what is the Intersite Radios" Tenderer Intends 18 No.s of Channels (Local and Wide) together. Please confirm which channels are connected in Wide area and share the repeater based network diagram connectivity to understand the network topology in format of Master and peer. As per Network diagram there is an Indication of Wireless link. Wireless link between "Indian bull bldg RPTR-2", "Ayurvedic College RPTR-2" and "Wood Resort / Barapada RPTR- 2"."parasik Hill RPTR Channel-4" & "Control Room". Tenderer Intends for Microwave as a Backhaul. Kindly provide the feasibility report for the Line of Sight (LoS) to establish the link. Most of DMR Portable Radios doesn't have Cloning cable and Cloning is possible using Programming software. So Kindly omit this Feature As tender intends for 5 years warranty for All equipments but the life cycle of AAD is not like an radios so we request you to change the clause to: 3 years for Radio main units, 1 year for battery devices, 1 year for all other AAD Intersite radio is the radios used for connecting repeater site- microwave radios for LOS sites and DMR RF patch radios for Non LOS sites. Refer BOM only for quantity. Parsik Hill Repeater will be the Master site and remaining all sites will be the Peer sites. Refer pg. No.#25 Site visit & Radio Coverage. Bidder is supposed to visit and submit detail site survey and radio coverage report prior to quoting. Radio_G. accessories We have not asked for Cloning cable. Warranty period will be from the date of successful Acceptance Test Procedure (ATP). Warranty for all the equipments including accessories will be 05 (Five) years except

6 Page No. #29 V. SPECIFICAIONS OF DISPATCHER FOR CONTROL ROOM 7 Page No. 17 Section B, Technical Specification, Digital Wireless Set, D 3 8 Page No. 20 Section B, Technical Specification, Digital Handheld Transreceiver, D 3 9 pg. No.#25 H. Mandatory Requirements: #5 Site visit / Radio Coverage 10 Page No # 26 Specification of Microwave Radio Link (1+1) - Qty -06 item line For dispatcher connectivity need clarification as follows: i. Does Master repeater required stand by ii. Connectivity Between Master repeaters to the Dispatcher server thru IP (Microwave) iii. Does the server needs any stand by iv. Does Analog patch is an part of this network v. Does local channels needs an GPS tracking at control room Humidity requested is 30 C 95% to 60 C 95% from 20 C 95% to 60 C 95% from Humidity requested is 30 C 95% to 60 C from 20 C to 60 C 95% from Need an extended time for making a proper survey and Solution freeze. So please Extend the tender date for 3-4 weeks. 1) Specifications given in the tender are specific to OEM, in this light kindly confirm weather M/s Maharashtra Police shall accept the MW product/link which will have deviations but meet functional requirement including key criteria of 50Km coverage and latency of less than 10ms along with successful track record at M/s Maharashtra Police? 2) Kindly confirm on quantity of laptops to be given with MW? 3) Repair training for MW radios cannot be extended. Request you to remove this requirement from MW clause batteries. Warranty of batteries will be 02 (Two) years. i. Master repeater requires stand by with manual changeover ii.connectivity Between Master repeaters to the Dispatcher server thru IP (Microwave) iii.dispatcher requires stand by with manual changeover iv. Analog patch is not the part of this network. v. Local channels needs an GPS tracking at control room 95% non condensing (30 C to 60 C )- Accepted 95% non condensing (30 C to 60 C )- Accepted Bidder should complete the survey & freeze the solution within stipulated period. 1) Specifications given in the tender are not specific to any OEM. Bidder should quote the product which complies the tender specification. 2) Quantity of laptop is mentioned in BOM. 3)

4) Kindly confirm if links are not feasible with towers having mentioned heights in tender due to LOS requirements M/s Maharashtra Police shall arrange the tower at their cost and release payment for supply part on account of delays on this front? 4) Refer pg. No.#25 Site visit & Radio Coverage. Bidder is supposed to visit and submit detail site survey and radio coverage report prior to quoting. 11 Page No # 35 MW BOM 1) Managed Ethernet Switch Quantity 24 No.'s is asked kindly clarify how this switches are proposed to be connected. or used in the NW? Network diagram do not throw light on this. 2) Can we use router in place of L3 Switch? In this case Makes such as D- Link and Netgear do not has router in their portfolio so can we propose other makes which has proven track record for similar application at Maharashtra Police 1) Managed Ethernet Switch will be used as 1 + 1 (Working + Standby Manual Changeover) for each MW link. 2)Router is not mentioned in MW BOM.

Clarification in Technical Specifications Bidder :M/s Syrma Technology Pvt. Ltd., Mumbai. Tender No. - 1936 Serial No DGP/17/6162/DMR-Navi Mumbai/69/2018 DMR System in UHF 400 Mhz. for Navi Mumbai (These clarifications are applicable for all the responding bidders) Sr. No. Tender Reference (Page No/ Clause No) 1 Page 3/clause IX 2 Page 19/clause H, sub clause 1-Equipment of Demo Tender Clause Latest Test Report along with letter of the tenderer giving technical specifications to the laboratory asking for latest report i.e. on or after March 2018, of the tendered item should be submitted. At the time of product evaluation bidder should bring adequate qty. of the e offered make & model radios, test jig, other test & measuring instruments required to demonstrate full functionality Radio Bidder's Observation/Queries We can submit ILAC (International Laboratory Accreditation cooperation) test certificate / report can be submitted. Please note that these report are generated during product launch or any new feature added to the radio, hence report may not exactly match the date provided in the tender. We request you to waive off the demo for larger participation and smooth tender process OR limited the Demo to 1 rptr, 2 portable and one mobile for testing the feature of DMR tier II radio. Accepted. Response to Queries/ Clarification

3 3 Page 19/clause H, sub clause 7- Warranty 4 Page 19-20- digital radio handheld, clause D, environmental specification, Sub clause 5 IP standard 5 page 22, clause 6- Training 05 years from successful acceptance procedure ( ATP). Warranty for all the equipment including accessories is 05 years. IP-68 Necessary technical training to be given to 30 wireless technical person for two weeks at Police HQ Pune. A) configuration of the system b) component level repairing and maintenance of the system We assume that warranty for handheld radio will be one year from the date of acceptance, kindly clarify We request to change the IP standard to ip-67 for larger participation from OEM. Operational & Configuration training will be provided, however component level repairing training is not possible. As there is warranty of 05 years and new digital IP-67/68 level radio's are very sophisticated in nature and can not be repaired in general lab environment. We request to delete this clause. 6 We request you to allow multiple OEM for this requirement to prove the interoperability which one of the prime criteria of DMR Tier II Warranty period will be from the date of successful Acceptance Test Procedure (ATP). Warranty for all the equipments including accessories will be 05 (Five) years except batteries. Warranty of batteries will be 02 (Two) years. Refer page 25, clause H-1 Interoperability.

Clarification in Technical Specifications Bidder :M/s Vertel Infotel Pvt. ltd. Tender No. - 1936 Serial No DGP/17/6162/DMR-Navi Mumbai/69/2018 DMR System in UHF 400 Mhz. for Navi Mumbai (These clarifications are applicable for all the responding bidders) Sr. No. Tender Reference (Page No/ Clause No) 1 Page No 33 (Sr.No.4) Tender Clause SMPS Power supply cum battery charger for Static Station.: Charger should have proper indicator and adjustable charging current. 2 Type of antenna : #Make: RFI/Comtelco / Sinclair/ DB Spectra/ Telewave /Andrew. 3 Page no 3 Clause IX Latest Lab Test Report on or after March 2018 Bidder's Observation/Queries Kindly clarify the feature "adjustable charging current." #Whether manual current adjustment knob is required? OR the power supply unit should have the inherent feature of automatically adjusting the current depending on the health of battery. Kindly note these brands of antenna are highly expensive as some of them even cost more than the radio equipment since these are designed for some customized/specific radio network and not available with desired gain. Hence, we request to either broaden the imported brands or add COMET-Japan, Tram-Browning- USA antenna manufacturer OR define the high end generic antenna specifications so that even indigenous antenna should also compete provided it complies with the specification. This may be worthy to mention here that now we have high quality of indigenously made antennas system and the bidders have to anyway maintain system for five years to your satisfaction, so a pragmatic view on the said issue is solicited. Please omit such time line as amended in previous tender of your dept. also. Response to Queries/ Clarification Bidders understanding is correct. The power supply unit should have the inherent feature of automatically adjusting the current Generally, OEMs get their models tested by NABL Accredited lab or ILAC at the

4 -- #Cat 6 SFTP cable Cat 6 armored cable is more resilient compared to Cat 6 SFTP & more suitable for your kind of operation. Please consider. 5 -- #Warranty Radio set warranty of 5-year warranty is okay. Please keep the warranty for all other items 1-year in line with industry terms. time of product introduction into the market to confirm that the model is meeting all the planned parameters. Bidder should provide this test report. Warranty period will be from the date of successful Acceptance Test Procedure (ATP). Warranty for all the equipments including accessories will be 05 (Five) years except batteries. Warranty of batteries will be 02 (Two) years.