TEST REPORT FROM RFI GLOBAL SERVICES LTD
|
|
- Jonathan Hampton
- 5 years ago
- Views:
Transcription
1 FROM RFI GLOBAL SERVICES LTD Test of: C-Track NX55 To: EN V1.6.1 ( ) in accordance with EN V1.4.1 ( ) Test Report Serial No.: RFI-RPT-RP84347JD02A This Test Report Is Issued Under The Authority Of John Newell, Group Quality Manager: Checked By: Ian Watch Signature: Date of Issue: 25 May 2012 This report is issued in Adobe Acrobat portable document format (PDF). It is only a valid copy of the report if it is being viewed in PDF format with the following security options not allowed: Changing the document, Selecting text and graphics, adding or changing notes and form fields. This report may not be reproduced other than in full, except with the prior written approval of RFI Global Services Ltd. The results in this report apply only to the sample(s) tested.
2 This page has been left intentionally blank. Page 2 of 11 RFI Global Services Ltd
3 Table of Contents 1. Customer Information Summary of Testing General Information Summary of Test Results Deviations from the Test Specification 5 3. Equipment Under Test (EUT) Identification of Equipment Under Test (EUT) Description of EUT Modifications Incorporated in the EUT Additional Information Related to Testing Support Equipment 6 4. Operation and Monitoring of the EUT during Testing Operating Modes Configuration and Peripherals 7 5. Measurements, Examinations and Derived Results General Comments Test Results Receiver Spurious Emissions 9 6. Measurement Uncertainty Appendix 1. Test Equipment Used RFI Global Services Ltd Page 3 of 11
4 1. Customer Information Company Name: Address: DigiCore Technology (Pty) Ltd Regency Office Park 9 Regency Drive Route 21 Corporate Park Irene Centurion South Africa Page 4 of 11 RFI Global Services Ltd
5 2. Summary of Testing 2.1. General Information Specification Reference: EN V1.6.1 ( ) Specification Title: Electromagnetic compatibility and Radio spectrum Matters (ERM); Short range devices; Radio equipment to be used in the 1 GHz to 40 GHz frequency range; Part 1: Technical characteristics and test methods Specification Reference: EN V1.4.1 ( ) Specification Title: Location of Testing: Test Date: 27 April Summary of Test Results Electromagnetic compatibility and Radio spectrum Matters (ERM); Short range devices; Radio equipment to be used in the 1 GHz to 40 GHz frequency range; Part 2: Harmonized EN covering the essential requirements of article 3.2 of the R&TTE Directive RFI Global Services Ltd, Wade Road, Basingstoke, Hampshire, RG24 8AH. Clause Measurement Result 8.3 Spurious Emissions Key to Results = Complied = Complied, within uncertainty = Did not comply, within uncertainty = Did not comply 2.3. Deviations from the Test Specification For the measurements contained within this test report, there were no deviations from, additions to, or exclusions from the test specification identified above. RFI Global Services Ltd Page 5 of 11
6 3. Equipment Under Test (EUT) 3.1. Identification of Equipment Under Test (EUT) Brand Name: C-Track Model Name or Number: NX55 Serial No.: Not marked or stated Hardware Version: 2.2 Software Version: F Description of EUT The equipment under test was a vehicle tracking device incorporating a GPS receiver Modifications Incorporated in the EUT None 3.4. Additional Information Related to Testing Category of Equipment: Short Range Device (SRD) Type of Radio Device: GPS Receiver with integral antenna Power Supply Requirement(s): Nominal 12 VDC Receive Frequency: MHz 3.5. Support Equipment The following support equipment was used to exercise the EUT during testing: Description: Brand Name: Serial No.: Data/power cable (3 metres) C-Track Not marked or stated Page 6 of 11 RFI Global Services Ltd
7 4. Operation and Monitoring of the EUT during Testing 4.1. Operating Modes The EUT was tested in the following operating mode(s): Continuously receiving Configuration and Peripherals The EUT was tested in the following configuration(s): The EUT was connected to a fully charged 12 Volt lead acid battery via the data/power cable during tests. RFI Global Services Ltd Page 7 of 11
8 5. Measurements, Examinations and Derived Results 5.1. General Comments Measurement uncertainties are evaluated in accordance with current best practice. Our reported expanded uncertainties are based on standard uncertainties, which are multiplied by an appropriate coverage factor to provide a statistical confidence level of approximately 95%. Please refer to Section 6 Measurement Uncertainty for details. Page 8 of 11 RFI Global Services Ltd
9 5.2. Test Results Receiver Spurious Emissions Test Summary: Test Engineer: David Doyle Test Date: 27 April 2012 Test Sample Serial No.: Not marked or stated Clause: 8.3 Test Method: Environmental Conditions: Temperature ( C): 21 Relative Humidity (%): 24 Results: Frequency (MHz) Bandwidth (khz) Level (dbm) Note(s): 1. All other emissions were found to be at least 6 db below the relevant limit. 2. All emissions below 1 GHz were measured using a quasi-peak detector Limit: Clause Frequency Range (MHz) 25 to to MHz Limit (dbm) RFI Global Services Ltd Page 9 of 11
10 6. Measurement Uncertainty No measurement or test can ever be perfect and the imperfections give rise to error of measurement in the results. Consequently the result of a measurement is only an approximation to the value of the measurand (the specific quantity subject to measurement) and is only complete when accompanied by a statement of the uncertainty of the approximation. The expression of uncertainty of a measurement result allows realistic comparison of results with reference values and limits given in specifications and standards. The uncertainty of the result may need to be taken into account when interpreting the measurement results. The reported expanded uncertainties below are based on a standard uncertainty multiplied by an appropriate coverage factor such that a confidence level of approximately 95% is maintained. For the purposes of this document approximately is interpreted as meaning effectively or for most practical purposes. Measurement Type Confidence Level (%) Calculated Uncertainty Radiated Spurious Emissions 95% ±2.94 db The methods used to calculate the above uncertainties are in line with those recommended within the various measurement specifications. Where measurement specifications do not include guidelines for the evaluation of measurement uncertainty the published guidance of the appropriate accreditation body is followed. Page 10 of 11 RFI Global Services Ltd
11 Appendix 1. Test Equipment Used RFI No. Instrument Manufacturer Type No. Serial No. A1534 Pre Amplifier Hewlett Packard 8449B 3008A00405 A1818 Antenna EMCO A253 Antenna Flann Microwave A254 Antenna Flann Microwave A255 Antenna Flann Microwave A288 Antenna Chase CBL6111A 1589 K0002 3m RSE Chamber Rainford EMC N/A N/A M1124 Spectrum Analyser Rohde & Schwarz ESI K NB In accordance with UKAS requirements all the measurement equipment is on a calibration schedule. RFI Global Services Ltd Page 11 of 11
TEST REPORT FROM RFI GLOBAL SERVICES LTD
FROM RFI GLOBAL SERVICES LTD Test of: CIBS To: FCC Part 15.247: 2008 Subpart C, RSS-210 Issue 7 June 2007 & RSS-Gen Issue 2 June 2007 Test Report Serial No: RFI/RPT2/RP75103JD05A Supersedes Test Report
More informationTEST REPORT FROM RFI GLOBAL SERVICES LTD
FROM RFI GLOBL SERVICES LTD Partial Test of: 5 To: FCC Part 5.247: 2008 Subpart C Test Report Serial No: RFI/RPT/RP79JD03 This Test Report Is Issued Under The uthority Of Brian Watson, Operations Director:
More informationTEST REPORT FROM RFI GLOBAL SERVICES LTD
FROM RFI GLOBAL SERVICES LTD Test of: Smart Gears Limited, Micro-tracker MT-01 To: 47CFR15.109 and RSS-GEN Issue 3 December 2010 Test Report Serial No: RFI-EMC-RP81827JD05A This test report is issued under
More informationTEST REPORT FROM RFI GLOBAL SERVICES LTD
FROM RFI GLOBL SERVICES LTD Partial Test of: BTM4 To: FCC Part 5.247: 08 Subpart C, RSS- Issue 7 June 07 & RSS-Gen Issue 2 June 07 Test Report Serial No: RFI/RPT/RP78JD03 This Test Report Is Issued Under
More informationTEST REPORT FROM RFI GLOBAL SERVICES LTD
TEST REPORT FROM RFI GLOBAL SERVICES LTD Test of: Ingenico France, IWL252-01T1535A To: 47CFR15.107, 47CFR15.109 and RSS-GEN Issue 3 December 2010 Test Report Serial No: RFI-EMC-RP82173JD02A V2.0 Version
More informationTEST REPORT FROM RFI GLOBAL SERVICES LTD
FROM RFI GLOBL SERVICES LTD Partial Test of: Motorola Point to Point Fixed Wireless Solutions PTP58 5.8 GHz band Wireless Ethernet Bridge To: FCC Part 5.47: 8 Subpart C, RSS- Issue 7 June 7 & RSS-Gen Issue
More informationTEST REPORT FROM RFI GLOBAL SERVICES LTD
FROM RFI GLOBAL SERVICES LTD Test of: Maestro Wireless Solutions Limited, Maestro 100evo To: EN 301 489-1 V1.8.1 referencing EN 301 489-7 V1.3.1 Test Report Serial No: RFI-EMC-RP78797JD02A This test report
More informationTest. Report. Manufacturer. Model No. FCC ID. Technology. and. 1. This. 3. This. pp John Newell. as UL. Date of Issue: 28 May 2013.
Test Report TESTT REPORT No. : UL-RPT-RP89265JD7 V3. Manufacturer Model No. FCC ID IC Certification No. Technology Test Standard(s) : & R Cambridge Ltd (RCM) : L22Y : YONDNW- : 792 -DNW : Bluetooth Basic
More informationTEST REPORT. Test Report No. : UL-RPT-RP JD03A V3.0. Date of Issue: 14 September pp John Newell Quality Manager, UL VS LTD
Test Report No. : UL-RPT-RP07443JD03 V3.0 Manufacturer : pple Inc. Model No. : 0 FCC ID : BCG0 Technology : Bluetooth Basic Rate & EDR Test Standard(s) : FCC Parts 5.7, 5.9(a) & 5.247. This test report
More informationTEST REPORT FROM RFI GLOBAL SERVICES LTD
FROM RFI GLOBAL SERVICES LTD Test Report Serial No: RFI/RPTE2/RP48909JD015A Supersedes Test Report Serial No: RFI/RPTE1/RP48909JD015A This Test Report Is Issued Under The Authority Of Michael Derby, Radio
More informationTEST REPORT FROM RADIO FREQUENCY INVESTIGATION LTD.
TEST REPORT FROM RADIO FREQUENCY INVESTIGATION LTD. Test Of: Wood & Douglas Ltd ST500 Transmitter Test Report Serial No: RFI/EMCB2/RP39403B This Test Report supersedes RFI Test Report No.: RFI/EMCB1/RP39403B
More informationTEST REPORT. Test Report No. : UL-RPT-RP JD02A V3.0. Date of Issue: 06 October 2017
Test Report No. : UL-RPT-RP11327903JD02A V3.0 Manufacturer : Kontakt Micro-Location Sp. z o.o. Model No. : Kontakt Smart Beacon 2 FCC ID : 2ADAO-SB2-V250 Technology : Bluetooth Low Energy Test Standard(s)
More informationNemko-CCL, Inc West Alexander Street Salt Lake City, UT
Nemko-CCL, Inc. 1940 West Alexander Street Salt Lake City, UT 84119 801-972-6146 Test Report Declaration of Conformity Test Of: MICRO-RM2.4 Test Specifications: ETSI EN 300 328 v1.7.1 (2006-10) Test Report
More informationTEST REPORT FROM RFI GLOBAL SERVICES LTD
TEST REPORT FROM RFI GLOBAL SERVICES LTD Serial No: RFI/RPTE2/RP49117JD07A Supersedes Serial No: RFI/RPTE1/RP49117JD07A This Is Issued Under The Authority Of Michael Derby, Wireless Radio Performance Group
More informationTEST REPORT. Test Report No. : UL-RPT-RP JD07H V2.0. Test Standard(s) : FCC Parts , , (a) &
TEST REPORT Test Report No. : UL-RPT-RP11265293JD07H V2.0 Manufacturer : Apple Inc. Model No. : A1785 FCC ID : BCG-E3088A Technology : NFC 13.56 MHz Test Standard(s) : FCC Parts 2.1049, 15.207, 15.209(a)
More informationSGS United Kingdom Ltd. International Electrical Approvals. Electromagnetic Compatibility. RF Card Entry System. PAC International Ltd.
South Industrial Estate Bowburn Co. Durham DH6 5AD United Kingdom Tel: +44 (0) 191 377 2000 Fax: +44 (0) 191 377 2020 email: sgsiea@sgs.com SGS United Kingdom Ltd. International Electrical Approvals Electromagnetic
More informationSTC Test Report. Date : Page 1 of 13 No. : HM161169
Date : 2009-05-11 Page 1 of 13 Applicant (ATS001): Atech Scientific Measurement Limited. Room A-C, 18 Floor, Luk Hop Ind. Bldg, 8 Luk Hop Street, Kowloon Manufacturer: Atech Scientific Measurement Limited.
More informationTest Report No
x Test Report No.8312314587 For Synel Industries Ltd. Equipment Under Test: Proximity Reader From The Standards Institution Of Israel Industry Division Telematics Laboratory EMC Section Certificate No.
More informationRadar Burst at the End of the Channel Availability Check Time (continued) Results: 20 MHz Master
Radar Burst at the End of the Channel Availability Check Time (continued) Results: 20 MHz Master Limits: Part 15.407(h)(2)(ii) Plot showing the radar fired at the end of CAC A U-NII device shall check
More informationEMC Bayswater Pty Ltd. EMC COMPLIANCE REPORT In accordance with: AS/NZS CISPR 15: Indice Ecotech Pty Ltd. 14W LED Downlight
EMC Bayswater Pty Ltd 52 Holloway Drive Bayswater, Victoria, 3153, Australia Telephone: +61 3 9762 4111 Facsimile: +61 3 9762 8519 Email: sales@emcbayswater.com.au ABN: 49 112 221 333 EMC COMPLIANCE REPORT
More informationSpurious Emissions & Emission Mark Report
Spurious Emissions & Emission Mark Report for the SRT Marine Technology Ltd Neon 403-0001 AIS Class B Transceiver No. Issue#1: 20 th July 2009 EU Notified Body FCC & VCCI Registered BSMI Lab ID: SL2-IN-E-3008
More informationTEST REPORT. Power Spout PLT V. tested to the specification. EN : Amendment 1: Electromagnetic compatibility (EMC)
EMC Technologies (NZ) Ltd PO Box 68-307, Newton Auckland 1145 New Zealand Phone 09 360 0862 Fax 09 360 0861 E-Mail Address: aucklab@ihug.co.nz Web Site: www.emctech.com.au TEST REPORT Power Spout PLT 100
More informationF C C - TESTREPORT REPORT NO.: FCC-02/
F C C - TESTREPORT REPORT NO.: FCC-02/09-0010 pkm Ohmstrasse 1 D-84160 Frontenhausen Tel : 08732-6381 Fax : 08732-2345 e-mail: pkm.accredited-labs@t-online.de Seite/page: 2 of 12 TABLE OF CONTENTS Page
More informationReport for Excelsys EMC Measurements for 4Xgen Purchase Order: Project Number EMT07J026 Rev. B
Report for Excelsys on EMC Measurements for 4Xgen Purchase Order: Project Number EMT07J026 Rev. B Rev Date Comment A April 2007 Change in DoC content B May 2007 Added Immunity Section EMT is a TÜV Appointed
More informationElectromagnetic Compatibility Test Report FCC test results of an automatic dog brush, model EUT: Type 1 AC/DC adaptor: SYS W2E
Electromagnetic Compatibility Test Report FCC test results of an automatic dog brush, model EUT: Type 1 AC/DC adaptor: SYS1308-1809-W2E Customer Customer's representative In the capacity of Reference number
More informationTRANSMITTER MODEL: KAS-2030M
Page 1 of 16 FCC PART 15, SUBPART B and C TEST REPORT for TRANSMITTER MODEL: KAS-2030M Prepared for WILDLIFE TECHNOLOGIES 115 WOLCOTT STREET MANCHESTER, NEW HAMPSHIRE 03103 Prepared by: KYLE FUJIMOTO Approved
More informationREMARKS The customer has ordered two measurements mentioned above according to the standard EN
Type: Alignment range: Switching range: SATELLINE-3ASm/250/LC 380,000-470,000 MHz One channel Equipment 1 and 2 Equipment Equipment Measurement Serial no. 033322036 and 033322037 Serial no. Serial no.
More informationEMI T E S T R E P O R T
EMI T E S T R E P O R T - FCC Part 15B - Test Report No. : T38935-00-02TK 27. November 2014 Date of issue Type / Model Name : One Touch Select Plus Flex Product Description : Blood glucose meter with Bluetooth
More informationEMC TEST REPORT. Report No.: TS EME Model No.: 33XR-A Issued Date: Jan. 08, 2009
Page 1 of 18 EMC TEST REPORT Report No.: TS08100063-EME Model No.: 33XR-A Issued Date: Jan. 08, 2009 Applicant: Test Method/ Standard: Test By: FLUKE CORP. 6920 Seaway Blvd, M/S 266D Everett, WA 98203
More informationTRFWL. Autostart Inc Rue Paré Mont-Royal, Québec Canada, H4P 2M2 EZSNAH2503
Nemko Test Report: 109054-1TRFWL Applicant: Autostart Inc. 5764 Rue Paré Mont-Royal, Québec Canada, H4P 2M2 Apparatus: ASRA 2503 FCC ID: EZSNAH2503 In Accordance With: FCC Part 15 Subpart B, 15.107 and
More informationTest. Report. : connectblue. Manufacturer. Model No. FCC ID 4.10, This. 3. This. as UL. Date of Issue: 22 May
Test Report TESTT REPORT No. : UL-RPT-RP86357JD01A V2.0 Manufacturer Model No. FCC ID IC Certification No. Test Standard(s) : connectblue : OWS451 : PVH0941 : 5325A-0941 : FCC Parts 15. 107, 15.109, 15.207,
More informationTest report TRFWL. Lotek Wireless Inc. SRX800 SRX A-SRX800. RSS-215 Issue 2, June Date of issue: July 11, 2014.
ONE WORLD OUR APPROVAL Test report 250123-2TRFWL Date of issue: July 11, 2014 Applicant: Lotek Wireless Inc. Product: SRX800 Model: SRX800 IC Registration number: 4272A-SRX800 Specification: RSS-215 Issue
More informationEMISSION TEST REPORT
Page 1 of 23 EMISSION TEST REPORT Test Report No. Applicant Address Manufacturer Address Type of Equipment Model Name Serial number Total page of Report : E05OR-057 : Win4NET Co., Ltd. : KOLON Digital
More informationRF Test Report. Report No.: AGC EE13 : VR 6600PRO, VR 6610, VR 6700, VRP 6000, VRP 6800 : VERO GLOBAL COMMUNICATION CO.
Page 1 of 52 RF Test Report PRODUCT DESIGNATION BRAND NAME TEST MODEL CLIENT : Dual Band Mobile Radio : VGC : VR 6600PRO, VR 6610, VR 6700, VRP 6000, VRP 6800 : VERO GLOBAL COMMUNICATION CO.,LTD DATE OF
More informationCompliance Engineering Ireland Ltd
Page 1 of 27 Compliance Engineering Ireland Ltd RAYSTOWN, RATOATH ROAD, ASHBOURNE, CO. MEATH, IRELAND Tel: +353 1 8256722 Fax: +353 1 8256733 Project Number: 10E2475-5 Prepared for: Biancamed Ltd By Compliance
More informationOUTDOOR SOUND MODULE/TRANSMITTER MODEL: THE BANDIT
Page 1 of 16 FCC PART 15, SUBPART B and C TEST REPORT for OUTDOOR SOUND MODULE/TRANSMITTER MODEL: THE BANDIT Prepared for MINASKA OUTDOORS 6517 PLATTE AVENUE LINCOLN, NEBRASKA 68507 Prepared by: KYLE FUJIMOTO
More informationTest report TRFWL. Texas Instruments Inc. CC3100 Booster-pack CC3100MODR11MAMOB ETSI EN V1.8.1 ( )
ONE WORLD OUR APPROVAL Test report 264561-4TRFWL Date of issue: November 20, 2014 Applicant: Texas Instruments Inc. Product: CC3100 Booster-pack Model: CC3100MODR11MAMOB Specifications: ETSI EN 300 328
More informationFCC & IC Certification. Test Report. FCC & Industry Canada Certification. Test Report. for Hetronic USA FCC ID: LW9-CS434TXN IC ID: 2219A-CS434TXN
FCC & IC Certification Test Report FCC & Industry Canada Certification Test Report for Hetronic USA March 3, 2005 Prepared for: Hetronic USA 4300 Highline Blvd Building 4 Oklahoma City, OK 73108 Prepared
More informationMeasurement of RF Emissions from a Caterpillar Inc. MSS3s RF ID Key Fob
Measurement of RF Emissions from a Caterpillar Inc. MSS3s RF ID Key Fob For Caterpillar Inc. 330 S.W. Adams Street Peoria, IL 61630 P.O. Number JBL 11260 Date Tested May 11, 2016 Test Personnel Mark Longinotti
More informationN : R2-E JDE :
TEST REPORT N : 821760-R2-E JDE : 133546 Subject Electromagnetic compatibility and Radio spectrum Matters (ERM) tests according to standards: EN 50364 (2010) EN 62369-1 (2009) Issued to Apparatus under
More informationRF Test Report. Report No.: AGC EE13. CLIENT : Zhengzhou Eshow Import and Export Trade Co.,Ltd.
Page 1 of 80 RF Test Report Report No.: AGC08074160901EE13 PRODUCT DESIGNATION : Two way radio BRAND NAME : Retevis MODEL NAME : RT1 CLIENT : Zhengzhou Eshow Import and Export Trade Co.,Ltd. DATE OF ISSUE
More informationTEST REPORT. PolyComp 32X80P7.621YHB Electronic Sign. tested to the. 47 Code of Federal Regulations. Part 15 - Radio Frequency Devices
EMC Technologies (NZ) Ltd PO Box 68-307 Newton, Auckland Phone 09 360 0862 Fax 09 360 0861 E-Mail Address: aucklab@ihug.co.nz Web Site: www.emctech.com.au TEST REPORT PolyComp 32X80P7.621YHB Electronic
More informationSILENT PARTNER Model No.: SCOOP FCC ID: WXMSCOOP. In Accordance With
SILENT PARTNER Model No.: SCOOP Applicant: DEUCE INDUSTRIES LTD 500 Coronation Drive Unit 10 Scarborough, ON CANADA, M1E 4V7 In Accordance With FEDERAL COMMUNICATIONS COMMISSION (FCC) Part 15, Subpart
More informationFrequency Range Peak Data Quasi-Peak Data Average Data (khz) (khz) (khz)
E M C ANTENNA GAIN Testing was performed using the mode(s) of operation and configuration(s) noted within the report. The individuals and/or the organization requesting the test provided the modes, configurations
More informationEN / EN RADIO TEST REPORT. Shanghai Anviz Technology Co.Ltd Fingerprint & RFID Time Attendance Model No.: A300
Page 1 of 28 Report No.: T1861387 02 EN 300 330-1/ EN 300 330-2 RADIO TEST REPORT On Behalf of Shanghai Anviz Technology Co.Ltd Fingerprint & RFID Time Attendance Model No.: A300 Prepared for : Shanghai
More informationFCC Report for Parts ,
FCC Report for Parts 15.247, 15.7 Product name Applicant FCC ID : WSN Node : Evalan : 2AK2M-EVAWSN-N15 Test report No. : 1100161 Ver 1.00 Laboratory information Accreditation Telefication is designated
More informationSHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: WXLRAMV Report No.: LCS E-03 FCC MPE TEST REPORT. 47 CFR FCC Part 2 2.
FCC MPE TEST REPORT 47 CFR FCC Part 2 2.1091 Report Reference No....: FCC ID....: Date of Issue....: Testing Laboratory Name...: Address...: Applicant s name...: Address...: Test specification...: LCS1511070542E-03
More informationUEI FUSION PLUS QWERTY KB REMOTE 2012 MODEL: URC-5110BC0-XXX-R
Page 1 of 16 FCC PART 15 SUBPART B and C TEST REPORT for UEI FUSION PLUS QWERTY KB REMOTE 2012 MODEL: URC-5110BC0-XXX-R Prepared for UNIVERSAL ELECTRONICS, INC. 201 EAST SANDPOINTE AVENUE, 8 TH FLOOR SANTA
More information1 Hines Rd. Ottawa, Ontario K2K 3C7. PCS Low Power Repeater. 303 River Road, R.R. 5 Ottawa, Ontario K1V 1H2. Authorized By:
Test Report: 3W06968 Applicant: Spotwave Wireless Inc. 1 Hines Rd. Ottawa, Ontario K2K 3C7 Equipment Under Test: (EUT) SpotCell 111/112 CU PCS Low Power Repeater In Accordance With: FCC Part 24, Subpart
More informationENGINEERING TEST REPORT NUMBER: EUS1. ON Model No.(s): BB-BONE-000 IN ACCORDANCE WITH: CFR 47, PART 15, SUBPART B, CLASS B VERIFICATION
ENGINEERING TEST REPORT NUMBER: 10216476EUS1 ON Model No.(s): BB-BONE-000 IN ACCORDANCE WITH: CFR 47, PART 15, SUBPART B, TESTED FOR: Circuitco Electronics 1380 Presidential, Suite 100 Richardson, Texas
More informationDATES OF TESTS: From 03/10/2014 to 20/10/2014 and 25/02/2015. Open area test site in Aunainville (28) - FRANCE. Page 2 out of 54
TEST CERTIFICATION FOR: FCC Certification NAME OF THE EQUIPMENT UNDER TEST: Serial number: Wireless conference access point Type: CONFIDEA WCAP G3 1440077150000C1 Reference / model (P/N): 71.98.0033 V
More informationTEST REPORT. For RFID READER/WRITER. In conformity with. FCC CFR 47 Part15 Subpart C
TEST REPORT For RFID READER/WRITER In conformity with FCC CFR 47 Part15 Subpart C Model: TR3XM-SD01 / TR3XM-SU01 / TR3XM-SN01 FCC ID: MK4TR3XM-SX01 Test Item: RFID READER/WRITER Report No: RY1203Z12R1
More informationEUROFINS PRODUCT SERVICE GMBH EN V Tracking solution. Bolero-LT2
EUROFINS PRODUCT SERVICE GMBH RADIO TEST-REPORT EN 300 440 V1.4.1 Tracking solution Bolero-LT2 TEST REPORT NUMBER: G0M-1103-1037-T-42 Eurofins Product Service GmbH Storkower Str. 38c, 15526 Reichenwalde,
More informationR. Grant, Wireless Group Manager
KTL Test Report: 9R02216 Applicant: Daniels Electronics Ltd. 43 Erie Street Victoria, BC V8V 1P8 Equipment Under Test: (E.U.T.) Transmitter (VT-3A130) In Accordance With: FCC Part 87, Subpart D Tested
More informationFCC PART 15, CLASS B MEASUREMENT AND TEST REPORT. NanJing JingZe Lighting Technology Co.,Ltd
FCC PART 15, CLASS B MEASUREMENT AND TEST REPORT For NanJing JingZe Lighting Technology Co.,Ltd No. 30, Hengfa Rd., National Economic Technological Development Zone, Nanjing, Jiangsu, China Tested Model:
More informationGSM TEST PARTIAL REPORT
GSM TEST PARTIAL REPORT 註解 [GH1]: change type depending on job Test of: FIC (First International Computer, Inc.) FIC GTA02 To ETSI EN 301 511 V9.0.2 (2003-03) Test Report Serial No: EG7D1802 Test Report
More informationAPPLICATION FOR CERTIFICATION On Behalf of Futaba Corporation Radio Control Model No.:T10CG-2.4G FCC ID:AZPT10CG-24G Brand : Futaba
FCC ID. AZPT10CG-24G Page 1 of 56 APPLICATION FOR CERTIFICATION On Behalf of Futaba Corporation Radio Control Model No.:T10CG-2.4G FCC ID:AZPT10CG-24G Brand : Futaba Prepared for : Futaba Corporation 1080
More informationReport for Excelsys EMC Measurements for 6Xgen Purchase Order: by Project Number EMT08J027
Report for Excelsys on EMC Measurements for 6Xgen Purchase Order: by email Project Number EMT08J027 Tom O Brien, Engineering Director ElectroMagnetic Technologies Ltd, Cork, June 2007 Executive Summary
More informationENGINEERING TEST REPORT
ENGINEERING TEST REPORT NUMBER: 10216476EICES1 ON Model No.(s): BB-BONE-000 IN ACCORDANCE WITH: ICES-003, ISSUE 4: 2004 TESTED FOR: Circuitco Electronics 1380 Presidential, Suite 100 Richardson, Texas
More informationPage 1 of 14 Report No Test Report 2119: EOPENBOX LIMITED. Product: OPENBOX V8S. Commercial-In-Confidence
Page 1 of 14 Report No. 2119 Test Report 2119: EOPENBOX LIMITED Product: OPENBOX V8S Commercial-In-Confidence Date: September 21 st 2016 Page 2 of 14 Report No. 2119 CONTENTS Section Page 1.0 Report Summary
More informationPage 1 of 20 No.: HM TEST REPORT FCC PART 15 SUBPART C CERTIFICATION REPORT FOR LOW POWER TRANSMITTER. TEST REPORT No.
Page 1 of 20 FCC PART 15 SUBPART C CERTIFICATION REPORT FOR LOW POWER TRANSMITTER Equipment Under Test [EUT]: Model Number: Applicant: FCC ID : Radio Controlled Tank FH002 Zhongshan Fu Hai Electronics
More informationEUROFINS PRODUCT SERVICE GMBH EN V1.6.1 EN V Asset tracker. Rock
EUROFINS PRODUCT SERVICE GMBH RADIO TEST- REPORT EN 300 440-1 V1.6.1 EN 300 440-2 V1.4.1 Asset tracker Rock TEST REPORT NUMBER: G0M-1103-1036-T-42 Eurofins Product Service GmbH Storkower Str. 38c, 15526
More informationRADIO TEST REPORT SHANGHAI EUCHIPS INDUSTRIAL CO.,LTD. Prepared By : SHANGHAI EUCHIPS INDUSTRIAL CO.,LTD
SHANGHAI EUCHIPS INDUSTRIAL CO.,LTD RADIO TEST REPORT Prepared For : SHANGHAI EUCHIPS INDUSTRIAL CO.,LTD 3rd and 4th Floor,6th Building No.888,Shuangbai Road, Minhang District,Shanghai,China Product Name:
More informationSHURE ELECTROMAGNETIC COMPATIBILITY LABORATORY TEST REPORT
SHURE ELECTROMAGNETIC COMPATIBILITY LABORATORY TEST REPORT TEST REPORT TITLE: Electromagnetic Compatibility Tests of the Shure QLXD2-V50 Handheld Transmitter TEST ITEM DESCRIPTION: QLXD2-V50 is a digital
More informationAPPROVED BY: DATE: 19-Aug-2011 Brian Boyea, EMC Engineer. TESTED BY: DATE: 12-Aug-2011 Arturo Ruvalcaba, EMC Engineer
ENGINEERING TEST REPORT NUMBER: 102127174EUS1 ON Model No.(s): MAVRK IN ACCORDANCE WITH: CFR 47, PART 15, SUBPART B, TESTED FOR: Texas Instruments, Inc. 12500 TI Boulevard MS 8712 Dallas TX 75243 TESTED
More informationRF Test Report. Report No.: AGC EE10. TEST NAME : 1999/5/EC R&TTE Directive Art.3.2 STANDARD(S) : EN V : V1.
Page 1 of 49 RF Test Report Report No.: AGC05278160201EE10 TEST NAME : 1999/5/EC R&TTE Directive Art.3.2 PRODUCT DESIGNATION : ihere3.0 BRAND NAME : ihere3.0 MODEL NAME : ihere3.0 CLIENT : No NDA Inc.
More informationJAPAN QUALITY ASSURANCE ORGANIZATION 21-25, KINUTA 1-CHOME, SETAGAYA-KU, TOKYO JAPAN PHONE (03) , FAX (03)
21-25, KINUTA 1-CHOME, SETAGAYA-KU, TOKYO 157-8573 JAPAN PHONE (03) 3416-0111, FAX (03) 3416-9691 EMI TEST REPORT JQA APPLICATION NO.: 400-20892 Issue Date : March 26, 2003 Page 1 of 23 JQA APPLICATION
More informationCONTENTS 1 GENERAL INFORMATION TEST INFORMATION TEST REPORT SUMMARY TEST RESULTS TEST GRAPHS... 12
Test report : 113914-3 Item tested Equipment type Client : nrf2728, nrf24lu1+ USB Dongle : 2.4 GHz Development Kit : Nordic semiconductor ASA Nemko AS is granted accreditation by Norwegian Accreditation
More informationTest Report: 5R Champlain Street Dieppe, New Brunswick Canada E1A 1P6. Model Number: Verification
Test Report: 5R46150.1 Applicant: Equipment Under Test: Model Number: In Accordance With: Tested By: Nanoptix Inc. 699 Champlain Street Dieppe, New Brunswick E1A 1P6 Spill Proof Cuts SPC FCC 47 CFR Part
More informationEMI -- T E S T R E P O R T
Registration No. DAT-P-207/05 EMI -- T E S T R E P O R T - FCC Part 15B - Test Report No. : T32619-00-04HU 24. July 2008 Date of issue Type / Model Name : R-PO7470 Product Description : Handheld Reader
More informationAS/NZS CISPR 14.1:2010 MEASUREMENT AND TEST REPORT
AS/NZS CISPR 14.1:2010 MEASUREMENT AND TEST REPORT For Tritech Technology Ltd. Unit B, 8/F, Chung Pont Commercial Building No. 300 Hennessy Road, WanChai, Hong Kong. Model: 209517 Report Type: Original
More information1 Introduction Test Specification Environment Relevant standards Emissions Immunity...
CONTENTS 1 Introduction... 4 2 Test Specification... 6 2.1 Environment... 6 2.2 Relevant standards... 6 2.2.1 Emissions... 6 2.2.2 Immunity... 7 3 Test Results... 8 3.1 Conducted emissions (9kHz to 30MHz)...
More informationETSI EN V1.1.1 ( )
EN 302 208-1 V1.1.1 (2004-09) European Standard (Telecommunications series) Electromagnetic compatibility and Radio spectrum Matters (ERM); Radio Frequency Identification Equipment operating in the band
More informationBS EN TESTS ON THE IT TOXIC GAS DETECTOR MODULE
Page 1 of 18 Interference Testing And Consultancy Services (Pty) Ltd ITC SERVICES (PTY) LTD Reg 88/002032/07 Plot 44 Kameeldrift East, Pretoria Private Bag X13 Lynn East 0039 Republic of South Africa Tel
More informationXBee Series 2 OEM RF Module Model No.: XBEE2 FCC ID: OUR-XBEE2. Applicant: MaxStream, Inc. 355 South 520 West Suite 180 Lindon, UT 84042
XBee Series 2 OEM RF Module Model No.: XBEE2 Applicant: MaxStream, Inc. 355 South 520 West Suite 180 Lindon, UT 84042 In Accordance With Federal Communications Commission (FCC) Part 15, Subpart C, Section
More informationADDENDUM TEST REPORT
Page : 1 of 19 ADDENDUM TEST REPORT Test Report No. : 11707924M Applicant : TAIYO YUDEN CO., LTD. Type of Equipment : Bluetooth Smart / ANT Module Model No. : EYSHCN Test standard : EN 300 328 V2.1.1 (Except
More informationETSI TR V1.1.1 ( )
TR 102 475 V1.1.1 (2006-07) Technical Report Electromagnetic compatibility and Radio spectrum Matters (ERM); Wideband Transmission Systems; Data transmission equipment operating in the 2,4 GHz ISM band
More informationTest Report: 4R Champlain Street Dieppe, New-Brunswick Canada E4P 8L6. Model Number: Verification
Test Report: 4R08185.1 Applicant: Equipment Under Test: Nanoptix Inc. 699 Champlain Street Dieppe, New-Brunswick E4P 8L6 EZ-Tear FX Model Number: 102103 In Accordance With: FCC 47 CFR Part 15, Subpart
More informationRADIO test report. According to the standards:
RADIO test report According to the standards: EN 300 220-1 v2.4.1 (2012-10) EN 300 220-2 v2.4.1 (2012-10) EN 300 220-1 V 3.1.1 (2017-02) EN 300 220-2 V 3.1.1 (2017-02) Equipment under test: Electronic
More informationPage 1 of 19 No.: HM TEST REPORT FCC PART 15 SUBPART C CERTIFICATION REPORT FOR LOW POWER TRANSMITTER. TEST REPORT No.
Page 1 of 19 FCC PART 15 SUBPART C CERTIFICATION REPORT FOR LOW POWER TRANSMITTER Equipment Under Test [EUT]: Model Number: Applicant: FCC ID : 1:6 Radio Control M5 Stuart Tank RC09037 21 st Century Toys
More informationF2 Labs Peters Road Middlefield, Ohio United States of America
F2 Labs 1674 Peters Road Middlefield, Ohio 4462 United States of America www.f2labs.com CERTIFICATION TEST REPORT Manufacturing Address: Applicant: Product Name: Product Description: Model(s): Beijing
More informationTEST SUMMARY Seite 2 von 19. Prüfbericht - Nr.: Test Report No.:
10050333 001 Seite 2 von 19 Page 2 of 19 TEST SUMMARY 5.1 CONDUCTED EMISSION PER SECTION 15.107, FCC 47 CFR PART 15 SUBPART B RESULT: Pass 5.2 RADIATED EMISSION PER SECTION 15.109, FCC 47 CFR PART 15 SUBPART
More informationTest Certificate A sample of the following product received on May 13, 2011 and tested on May 13, 18 and 19, 2011 complied with the requirements of,
Test Certificate A sample of the following product received on May 13, 2011 and tested on May 13, 18 and 19, 2011 complied with the requirements of, EN 301 489-1 V1.8.1 Electromagnetic compatibility and
More informationChapter I - Federal Communications Commission Subchapter A - General Part 15 - Radio Frequency Devices Subpart C - Intentional Radiators
www.nemko.com Report Reference ID 167484-1TRFWL Test specification Title 47 - Telecommunication Chapter I - Federal Communications Commission Subchapter A - General Part 15 - Radio Frequency Devices Subpart
More informationItron, Inc. TEST REPORT FOR. RF Telemetry Device Model: CCU100. Tested To The Following Standards:
Itron, Inc. TEST REPORT FOR RF Telemetry Device Model: CCU100 Tested To The Following Standards: FCC Part 15 Subpart C Sections 15.247 and RSS 210 Issue 8 Date of issue: April 25, 2013 This test report
More informationVersion TEST REPORT NO. DATE DESCRIPTION
Version NO. DATE DESCRIPTION HCTR1302FR13 February 14, 2013 - First Approval Report - Additional Model Name Page 2 of 25 Table of Contents 1. GENERAL INFORMATION... 4 2. EUT DESCRIPTION... 4 3. TEST METHODOLOGY...
More informationFCC Part Transmitter Certification. Test Report
FCC Part 15.247 Transmitter Certification Hybrid Spread Spectrum Transmitter Test Report FCC Rule Part: 15.247 ACS Report Number: 04-0170-15C247 Manufacturer: Onity, Inc. Equipment Type: Modular Radio
More informationTRANSMITTER Model: TX24
FCC Part 15 Subpart B and FCC Section 15.231 Test Report Page 1 of 17 FCC PART 15 SUBPART B and C TEST REPORT for TRANSMITTER Prepared for FOPRO, INC. 14 FO HOLLOW DRIVE LEWISTOWN, PENNSYLVNIA 17044 Prepared
More informationNemko-CCL, Inc West Alexander Street Salt Lake City, UT
Nemko-CCL, Inc. 1940 West Alexander Street Salt Lake City, UT 84119 801-972-6146 Test Report Declaration of Conformity Test Of: MICRO-RM2.4 Test Specifications: EN 301 489-1 V1.9.2 (2011-09) as specified
More informationA RADIO TEST REPORT FOR. MICROWAVE SOLUTIONS Ltd X-BAND DOPPLER MOTION DETECTOR UNITS MODEL NUMBER MDU1720 DOCUMENT NO.
A RADIO TEST REPORT FOR MICROWAVE SOLUTIONS Ltd ON X-BAND DOPPLER MOTION DETECTOR UNITS MODEL NUMBER MDU1720 DOCUMENT NO. TRA-012363-W-NA-1 TRaC Wireless Test Report : TRA-012363-W-NA-1 Applicant : Microwave
More informationMatric Limited Hill City Road R.R. #1 Box 421A Seneca, PA 16346
FCC CERTIFICATION TEST REPORT for Hill City Road R.R. #1 Box 421A Seneca, PA 16346 FCC ID: K5B-TP105 May 14, 2001 Revised: June 18, 2001 WLL PROJECT #: 6182X This report may not be reproduced, except in
More informationMeasurement of RF Interference from a Canopy 900MHz Access Point and Subscriber Module Using A Yagi Antenna
Measurement of RF Interference from a Canopy 900MHz Access Point and Subscriber Module Using A Yagi Antenna For : Motorola, Inc. 1301 East Algonquin Road Schaumburg, IL 60196 P.O. No. : 40335 Date Tested
More informationFCC Test Report. : ASE Group 4F,No 133, Sec 4, Mingsheng E Rd, Songshan Dist, Taipei, Taiwan
FCC Test Report Equipment : Wireless Pedometer/Tracker Brand Name : ASE Group Model No. : M903 Standard : 47 CFR FCC Part 15B Device Class : Class B Applicant Manufacturer : ASE Group 4F,No 133, Sec 4,
More informationEMC Test Report. Tested by: Jeremy O. Pickens, Senior EMC Engineer. Reviewed by: David Schramm, EMC/RF/SAR/HAC Manager
Page: 1 of 24 EMC Test Report Project Number: 4104971 Report Number: 4104971EMC01 Revision Level: 0 Client: Tier One, Inc. Equipment Under Test: GEN4 Glock Sensor Model Number: BA10232 FCC ID: 2AJ3810232
More informationETSI EN V2.1.1 ( ) TEST REPORT WIN CHANNEL ELECTRONICS (HK) CO., LTD
ETSI EN 300 296 V2.1.1 (2016-03) TEST REPORT For WIN CHANNEL ELECTRONICS (HK) CO., LTD No.1, Shangxing Road, Shangjiao, Changan Town, Dongguan, Guangdong, China Tested Model: 318EU Multiple Models: 73500,
More informationQI HARDWARE INC. Ben NanoNote. Model: Ben NanoNote September Report No.: (This report supersedes NONE)
QI HARDWARE INC. Ben NanoNote September 24 2009 Report No.: (This report supersedes NONE) Modifications made to the product : See page 6 This Test Report is Issued Under the Authority of: Andy.Hao Compliance
More informationTEST REPORT. Building 6, XinXinTian Industrial Park, XinSha Road, ShaJing, Baoan District, ShenZhen, China. Shenzhen Innokin Technology Co.
TEST REPORT Applicant Address Shenzhen Innokin Technology Co., Ltd Building 6, XinXinTian Industrial Park, XinSha Road, ShaJing, Baoan District, ShenZhen, China Manufacturer or Supplier Address Product
More informationFor. Unit D16/F. should not use it to claim FCC ID: 2AAIN-MNGLOS
Page 1 of 49 TESTT REPORT For Applicant : ACOUSTMAX INTERNATIONAL CO.., LTD Unit D16/F Cheuk Nang Plaza 250 Hennessy Road Address : WanchaiHongKong Product Name : Monster GLO Model Name : MNGLO-S, MNGLO-L,MNGLO-M,MNGLO-Mini
More informationNemko Canada Inc., 303 River Road, R.R. 5, Ottawa, Ontario, Canada, K1V 1H2
www.nemko.com Nemko Canada Inc., 303 River Road, R.R. 5, Ottawa, Ontario, Canada, K1V 1H2 Report Number: Product Marketing Name: 123766-1TRFEMC Paycheck 4 Thermal Ticket Printer Test Specification: FCC
More informationTEST REPORT. Power Spout PLT V. tested to the specification
EMC Technologies (NZ) Ltd PO Box 68-307 Newton, Auckland 1145 New Zealand Phone 09 360 0862 Fax 09 360 0861 E-Mail Address: aucklab@ihug.co.nz Web Site: www.emctech.com.au TEST REPORT Power Spout PLT 100
More information