Research Article Transformer Winding Deformation Profile using Modified Electrical Equivalent Circuit

Similar documents
Research Article A Simplified High Frequency Model of Interleaved Transformer Winding

IJSRD - International Journal for Scientific Research & Development Vol. 2, Issue 04, 2014 ISSN (online):

CHAPTER 2 ELECTROMAGNETIC FORCE AND DEFORMATION

CHAPTER 3 SHORT CIRCUIT WITHSTAND CAPABILITY OF POWER TRANSFORMERS

Transformer Engineering

Vallabh Vidyanagar, Anand, INDIA

FRAX Series Sweep Frequency Response Analyzers

Electromagnetic Force Modification in Fault Current Limiters under Short-Circuit Condition Using Distributed Winding Configuration

Chapter 7 Conclusion 7.1 General

Characterization of Power Transformer Electromagnetic Forces Affected by. Winding Faults

Fault Detection in Transformer Using Frequency (Sweep) Response Analysis

936 IEEE TRANSACTIONS ON POWER DELIVERY, VOL. 22, NO. 2, APRIL /$ IEEE

FRAX Series Sweep Frequency Response Analyzers

Field Experience with Sweep Frequency Response Analysis for Power Transformer Diagnosis

متلب سایت MatlabSite.com

Investigating Mechanical Integrity in Power Transformer Using Sweep Frequency Response Analysis (SFRA)

EFFECT OF RADIAL AND AXIAL MOVEMENT OF WINDING ON COHERENCE FUNCTION IN A 220/132 KV, 100 MVA, AUTO TRANSFORMER

Department of Electrical and Computer Engineering. Noise Detection and Elimination in Online Impulse Frequency Response Analysis

FAULT IDENTIFICATION IN TRANSFORMER WINDING

INTERPRETATION METHODOLOGY TO IDENTIFY FAULT LOCATION IN A POWER TRANSFORMER

Matz Ohlen Director Transformer Test Systems. Megger Sweden

Importance of Transformer Demagnetization

The Study of Magnetic Flux Shunts Effects on the Leakage Reactance of Transformers via FEM

Improved Method for Winding Deformation Detection Sensitivity in Transformer

Transformer Winding Deformation Analysis using SFRA Technique

Power Transformer Condition Assessment Based on Standard Diagnosis

A Literature Survey on Frequency Response Analysis for Detection of Transformer Winding Fault

ABB September Slide 1

CHAPTER 2. v-t CHARACTERISTICS FOR STANDARD IMPULSE VOLTAGES

Innovative Test Techniques and Diagnostic Measurements to Improve the Performance and Reliability of Power System Transformers

TesTIng of Power. Transformers are the largest, most. feature. By brandon dupuis

ISSN: X Impact factor: (Volume 3, Issue 6) Available online at Modeling and Analysis of Transformer

Assessment of Winding Deformation in Power Transformer using SFRA and Numerical Techniques Ashwini Bhujangrao Gaikwad

Shunt Capacitance Influences on Single-Phase Transformer FRA Spectrum

3. What is hysteresis loss? Also mention a method to minimize the loss. (N-11, N-12)

MECHANICAL faults in transformers can pose a great threat to electric power system. There are many

Advanced Test Equipment Rentals ATEC (2832)

ANALYSIS OF TRANSIENT ACTIONS INFLUENCE IN POWER TRANSFORMER

Transformer Winding Design. The Design and Performance of Circular Disc, Helical and Layer Windings for Power Transformer Applications

Loss prophet. Predicting stray losses in power transformers and optimization of tank shielding using FEM

Comprehensive modeling of Dry type foil winding transformer to analyse inter turn insulation under Lightning Impulse Voltage

FRANEO 800. The next generation for a reliable core and winding diagnosis of power transformers

Practical Transformer on Load

. B 0. (5) Now we can define, B A. (6) Where A is magnetic vector potential. Substituting equation (6) in to equation (2),

FRAX 101 Sweep Frequency Response Analyzer

AC Circuit. What is alternating current? What is an AC circuit?

FRAX Series Sweep Frequency Response Analyzers

Understanding the Value of Electrical Testing for Power Transformers. Charles Sweetser, OMICRON electronics Corp. USA

Transformers handling and transport

Effective Maintenance Test Techniques and Diagnostic Measurements to Improve the Performance and Reliability of Power System Transformers

Target Temperature Effect on Eddy-Current Displacement Sensing

Core Technology Group Application Note 1 AN-1

ANALYSIS OF TRANSIENT ACTIONS INFLUENCE IN POWER

Hidden schematics of EMI filters

Benefits of SFRA - Case Studies

Electromagnetic Interference Shielding Effects in Wireless Power Transfer using Magnetic Resonance Coupling for Board-to-Board Level Interconnection

Finite Element Analysis and Test of an Ultrasonic Compound Horn

Reduction stray loss on transformer tank wall with optimized widthwise electromagnetic shunts

ADVANCES in NATURAL and APPLIED SCIENCES

TECHNIQUES AND STANDARD

VIBRATION ESTIMATION, ASSESSMENT AND PROGNOSIS IN ELECTRICAL MACHINES

Effective maintenance test techniques for power transformers

DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING QUESTION BANK SUBJECT CODE & NAME : EE 1402 HIGH VOLTAGE ENGINEERING UNIT I

Enhance the Sensibility of the Eddy Current Testing

By Gill ( ) PDF created with FinePrint pdffactory trial version

Electrical Design Process

The effect analysis of single-double layers concentrated winding on squirrel cage induction motor

Investigation of Inter-turn Fault in Transformer Winding under Impulse Excitation

Citation Electromagnetics, 2012, v. 32 n. 4, p

Modal Analysis and Harmonic Analysis of a Conformal Antenna for Automobile Applications

Transcutaneous Energy Transmission Based Wireless Energy Transfer to Implantable Biomedical Devices

Over-voltage Trigger Device for Marx Generators

Performing reliable and reproducible frequency response measurements on power transformers

(2) New Standard IEEE P (3) Core : (4) Windings :

Design and Simulation of sierpinski carpet stacked microstrip fractal antenna

Diagnostic testing of cast resin transformers

Lumped Network Model of a Resistive Type High T c fault current limiter for transient investigations

Transformer Shunt Fault Detection using Two Techniques

Research Article Diagnosing Integrity of Transformer Windings by Applying Statistical Tools to Frequency Response Analysis Data Obtained at Site

Transformers. Dr. Gamal Sowilam

How to overcome undesirable effects ABSTRACT KEYWORDS. 1. Introduction

Study on the Transfer Functions for Detecting Windings Displacement of Power Transformers with Impulse Method

Development and verification of printed circuit board toroidal transformer model

Shielding Effect of High Frequency Power Transformers for DC/DC Converters used in Solar PV Systems

Understanding and Extracting Valuable Information from Basic and Advanced Power Transformer Testing Techniques

Determination of Transmission and Reflection Parameters by Analysis of Square Loop Metasurface

Cylindrical rotor inter-turn short-circuit detection

Picture perfect. Electromagnetic simulations of transformers

RESIDUAL LIFE ASSESSMENT OF GENERATOR TRANSFORMERS IN OLD HYDRO POWER PLANTS

Fuzzy Logic Based Identification of Deviations in Frequency Response of Transformer Windings

MODELING OF MECHANICAL STRESS PROCESS OF TRANSFORMER WINDING CAUSED BY SHORT CIRCUIT CURRENTS

UNIVERSITY OF TECHNOLOGY By: Fadhil A. Hasan ELECTRICAL MACHINES

2.5D Finite Element Simulation Eddy Current Heat Exchanger Tube Inspection using FEMM

Winding Function Analysis Technique as an Efficient Method for Electromagnetic Inductance Calculation

Wireless Power Transfer. CST COMPUTER SIMULATION TECHNOLOGY

ANALYSIS OF OPERATION MODE AND PERFORMANCE INDICATORS OF A TRANSFORMER WHEN CONTROLLING ITS VOLTAGE WITH AN ALTERNATING MAGNETIC FLUX

Design of Broadband Transition Structure from Microstrip to Slotline with Band Notched Characteristic

Research Article Survey of Induced Voltage and Current Phenomena in GIS Substation

Optimized shield design for reduction of EMF from wireless power transfer systems

FGJTCFWP"KPUVKVWVG"QH"VGEJPQNQI[" FGRCTVOGPV"QH"GNGEVTKECN"GPIKPGGTKPI" VGG"246"JKIJ"XQNVCIG"GPIKPGGTKPI

Transcription:

Research Journal of Applied Sciences, Engineering and Technology 9(4): 288-295, 215 DOI:1.1926/rjaset.9.147 ISSN: 24-7459; e-issn: 24-7467 215 Maxwell Scientific Publication Corp. Submitted: August 13, 214 Accepted: October 12, 214 Published: February 5, 215 Research Article Transformer Winding Deformation Profile using Modified Electrical Equivalent Circuit M. Arul Sathya and S. Usa Division of High Voltage Engineering, College of Engineering Guindy, Anna University, Chennai- 6 25, Tamil Nadu, India Abstract: This study presents a generalized methodology to predict the transformer winding deformation profile through Sweep Frequency Response Analysis using Finite Element Method based Magneto Structural Analysis and proposed modified equivalent circuit. Monitoring and diagnosis of fault in any power apparatus is necessary to increase the quality life of the apparatus. In general all the power transformers are designed to withstand the mechanical forces due to short circuit faults. However, mechanical forces may exceed the specified limits during severe incidents leading to winding deformation. Winding deformation is one of the causes for the power transformer outages. In the present work, deformation profile of the winding for different short circuit currents are computed using Finite Element Method based Magneto-structural analysis. The change in circuit parameters of the deformed windings are computed using Finite Element Method based field analyses and the corresponding Sweep Frequency Responses are obtained using the modified electrical equivalent circuit. From the change in resonance frequencies, the displacement profile of the winding can be predicted which will be useful for design engineers to check the withstand capability of transformer. Keywords: Finite element method, RLC parameters, sweep frequency response analysis, transformer winding deformation INTRODUCTION In general, the magnitude of the fault currents depends upon the short circuit reactance of the test transformer (Waters, 1966). These currents cause high leakage flux which can be resolved into radial flux and axial flux resulting in axial and radial forces respectively. Depending on the distribution of forces and mechanical integrity of the windings the weakest region undergoes winding deformation. These forces not only displace/deform the windings but also affect the other transformer components such as clamping ring, flitch plates and frames. Geometrical changes in the windings cause deviations in its resonance frequencies indicating the positional or electrical variations of the internal components (Kraetge et al., 29). Sweep Frequency Response Analysis (SFRA) is a powerful method for the detection and diagnosis of defects in the active part of power transformer which can deliver valuable information about the mechanical as well as the electrical changes in the windings parameters. Kulkarni and Kumbhar (27) have computed the force distribution due to short-circuit current in a splitwinding transformers using Finite Element Analysis (FEA). Faiz et al. (28) have analyzed the radial and axial electromechanical forces developed by the inrush and short circuit currents using 2D and 3D Finite Element Method (FEM) models. Ahn et al. (212) have compared the simulated and measured forces in windings. Zhang et al. (214) have compared the frequency responses of both undeformed and radially deformed winding. Wang et al. (21) have investigated the relationship between the winding deformation and the Vibration Sweep Frequency Response (VSFR) for 22kV transformer. Hashemnia et al. (212) have simulated the frequency response signature for various mechanical faults such as axial displacement, buckling stress, disc space variation and bushing fault. In the present study, deformation profile of the winding for different short circuit currents are computed using Magneto-structural analysis. The change in circuit parameters of the deformed windings are computed using Finite Element Method (FEM) based field analyses and the corresponding Sweep Frequency Responses (SFR) are obtained using the proposed modified electrical equivalent circuit. The above mentioned methodology will be useful for the design engineers in analyzing the force, displacement profiles, the resulting shift in resonant frequency and the change in impedances. Corresponding Author: M. Arul Sathya, Division of High Voltage Engineering, College of Engineering Guindy, Anna University, Chennai- 6 25, Tamil Nadu, India This work is licensed under a Creative Commons Attribution 4. International License (URL: http://creativecommons.org/licenses/by/4./). 288

Fig. 1a: Details of the test transformer Fig. 1b: Windings connection MATERIALS Winding under study: The transformer under study has two identical windings with 4 discs per winding as shown in Fig. 1a. Each disc has 1 turns. The windings are connected in such a way to simulate a transformer with the winding currents in the opposite directions (Fig. 1b). METHODS Displacement profile using magneto structural analysis: The electromagnetic force distribution and displacements in the windings are computed using FEM based Magneto-structural analysis. To check the computational methodology, short circuit test as per IEC Standard 676-5 was conducted on similar windings with two discs per winding at On Load Gears, Ambattur, Chennai (Sathya et al., 213) and the simulation results were validated with experimental displacements. Hence, the methodology is extended for 4 discs per winding (Fig. 1) for different currents. Both the windings are energized equally for different short circuit currents in the opposite directions and the corresponding axial displacements along the length of the windings are computed using Magnetostructural analysis. It is observed that the displacements of the discs are not uniform and the geometrical representation of the windings with displaced disc positions for different current densities is given in Fig. 2. Circuit parameters of displaced windings: In general, the transformer winding are modeled using R (resistance), L (inductance), C (capacitance) ladder network. FEM based Electromagnetic field solvers are used to extract the C (inter-turn (C t ) and inter-disc (C d ) capacitance and stray capacitance (C g ), L (self and 289 mutual inductance) and R (resistance) of the winding. Figure 3 shows the details of the top/bottom winding. Winding capacitance: The series capacitance of the winding is composed of two parts, inter-turn capacitances (C t ) and inter-disc capacitances (C d ). For axial deformation of transformer winding, the inter-turn capacitance remains the same whereas the inter disc capacitances changes as the distance between the discs vary. The capacitances are obtained by solving FEM based Electrostatic solver. Based on the displacements due to different currents, inter-disc capacitance for different gaps from.33-.3 m is computed (Fig. 4). The inter-turn capacitance of one disc is found to be 1.58 pf. Stray/shunt capacitance (C g ) is also calculated using Electrostatic solver. Winding inductance: For axial deformation of the transformer winding, the self inductance of the winding remains same and the mutual inductance between the windings change with the displacement. The total inductance of the winding is computed from total magnetic energy. In the case of multi-turns and/or multi-disc windings, there will be two inductive components namely self and mutual inductance between two sections. If the mutual inductance between the discs is L 12, the magnetic linkages λ 1 and λ 2 will be: λ =L I +L I (1) λ =L I +L I (2) With L 1, L 2 the self inductance of the discs of 1 and 2 respectively and (L 21 = L 12 = M) the mutual inductance between the discs. The total magnetic energy is: W = [L I + 2 L I I +L I ] (3)

Fig. 2: Geometrical representation of the deformed windings for different current densities Fig. 3: Transformer winding Inter-disc capacitance (pf) 45 4 35 3 25 2 15 1 5.5.1.15.2.25.3.35 Gap between the disc (m) Fig. 4: Inter-disc capacitance for different inter disc distances 29

Mutual coupling coefficient Fig. 5: Inductive coupling factor for different inter disc distances Resistance in ohms.8.7.6.5.4.3.2.1 3.5 3 2.5 2 1.5 1.5.1.2.3.4.5.6.7.8 Gap between the disc (m) 2 4 6 8 1 12 Frequency in MHz Fig. 6: Variation of winding resistance with frequency In this case, since I 1 = I 2 and L 1 = L 2, the mutual inductance is: = (4) and the mutual coupling coefficient (k 12 ) is: = (5) Magneto static solver is used to extract the inductances. The self-inductance of a disc is found to be 32.27µH. The change in the mutual coupling coefficient between the discs for different gaps is shown graphically in Fig. 5. Winding resistance: The change in winding resistance with frequency due to skin effect is carried out by solving FEM based Eddy Current Solver and is shown in Fig. 6. By using these equivalent circuit parameters, the SFRA are carried out. RESULTS Modified electrical equivalent circuit: Electrical equivalent circuit of transformer winding is represented by a combination of winding resistance, selfinductance, mutual inductance, inter-turn capacitance, inter-disc capacitance and stray capacitance. The basic electrical equivalent circuit of a transformer winding is shown in Fig. 7. The SFR for the unexcited winding is obtained using circuit simulation package and shown in Fig. 8. In the above equivalent circuit, the inter-turn and inter-disc capacitances are represented as single capacitance (C s ). Due to axial deformation, there will be a change in inter disc capacitance which can be appropriately incorporated by separating the series winding capacitances (C s ) into inter turn (C t ) and interdisc capacitance (C d ) and the varying inductive Fig. 7: Electrical equivalent circuit (basic circuit) of the winding Table 1: Percentage change in resonance frequencies % Error between simulated models Resonant frequency Electrical equivalent circuit model (simulated) ------------------------------------------------------- and measured ------------------------------------------------- in (MHz) Basic Modified Measured Basic Modified f r1 2.73 2.696 2.697-1.2.4 f r2 4.35 4.417 4.325 6.7-2.13 291

4 DB(v(L12:2)) Magnitude (db) -4-8 1 1.k 1k 1k 1.k 1k 1k Frequency (Hz) Fig. 8: Sweep frequency response of the unexcited winding (using basic circuit) Fig. 9: Modified electrical equivalent circuit of the winding Magnitude (db) Fig. 1: Sweep frequency response of the unexcited winding with modified circuit Magnitude (db) 2-2 -4-6 -1-2 -3-4 -5-6 DB(v(L12:2)) 1 1.k 1k 1k 1.k 1k 1k Frequency (Hz) 1 1k 1k 1k 1M 1M Frequency (Hz) Fig. 11: Sweep frequency response of the unexcited winding (Measured) 292 coupling (k) between the discs are also incorporated. Figure 9 shows the proposed modified electrical equivalent circuit with separated C t and C d. and the corresponding frequency response is shown in Fig. 1. The SRF of the winding is also measured using a Sweep Frequency Response Analyzer (FRAX 11, Megger make) and is shown in Fig. 11. From Fig. 8, 1 and 11, it is observed that SFR is improved with modified circuit (Table 1) and hence the modified circuit is considered for the further analyses. DISCUSSION SFRs for deformed windings: The proposed modified electrical equivalent circuit can model both axially and radially deformed winding by appropriately considering the changes in C d, k and C t, L respectively. In the present study, the windings are deformed only in axial direction due to radial force. For the displacements of discs reported in Section 3 for different currents, the corresponding C d and k (Fig. 4 and 5) are incorporated appropriately in the proposed modified electrical equivalent circuit and the corresponding SFRs are computed. Figure 12a shows the computed SFRs of the top winding. The windings are manually displaced and SFRs are measured for both the windings using SFR and Fig. 12b shows the measured SFRs of the top winding for different currents. It is observed from Fig. 12a and b,

Fig. 12a: SFRs of the top winding for different currents (simulated) Fig. 12b: SFRs of the top winding for different currents (measured) Fig. 13a: Shift in f r1 of bottom winding (measured) 293

Fig. 13b: Shift in f r1 of bottom winding (simulated) % Change in resonant frequency Fig. 14a: Percentage shift in fr1 for top winding % Change in resonant frequency 16 14 12 1 8 6 4 2.E+ 5.E+6 1.E+7 1.5E+7 2.E+7 1 9 8 7 6 5 4 3 2 1 Measured (SFRA) Simulation (PSpice) Current density in A/m 2 Measured (SFRA).E+ 5.E+6 1.E+7 1.5E+7 2.E+7 Current density in A/m 2 Fig. 14b: Percentage shift in fr1 for bottom winding the varied displacements between the windings are modeled effectively using the proposed modified circuit with less than 4% error. It is also observed that the shift 294 in first resonant frequency is predominant (Fig. 12a and b) and hence only the first resonant frequency is considered for forthcoming analyses. Similarly the measured and simulated f r1 of bottom winding are shown in Fig. 13a and b respectively. It is observed that the fr1 reduces with increasing currents and the same trend is observed in both measured and simulated SFRs for both the windings. For different short circuit currents, the percentage change in f r1 for top and bottom windings are given in Fig. 14a and b, respectively. When the SFR of a deformed winding is obtained, the shift in the f r1 can be calculated with the help of the unexcited SFR signature from which the magnitude of the excitation current and the corresponding winding deformation profile can be predicted from Fig. 14. The above analysis can also be used to predict the withstand capability of transformer by calculating the winding impedance from the deformed winding dimensions at the design stage itself as per IEC Standard 676-5. CONCLUSION The displacement of the transformer windings are computed using Finite Element Method based Magneto-structural analysis for different short circuit currents. The corresponding shift in resonance frequencies are predicted using the proposed modified electrical equivalent circuit and compared with measurement. The discussed approach will be useful for the design engineers in estimating the force, displacement profiles, change in SFRs and also the change in impedances for any short circuit currents at the design stage itself.

REFERENCES Ahn, H.M., Y.H. Oh, J.K. Kim and J.S. Song, 212. Experimental verification and finite element analysis of short-circuit electromagnetic force for dry-type transformer. IEEE T. Magn., 48(2): 819-822. Faiz, J., B.M. Ebrahimi and T. Noori, 28. Three- and two-dimensional finite-element computation of inrush current and short-circuit electromagnetic forces on windings of a three-phase core-type power transformer. IEEE T. Magn., 44(5): 59-597. Hashemnia, N., A. Abu-Siada, M.A.S. Masoum and S.M. Islam, 212. Characterization of transformer FRA signature under various winding faults. Proceeding of International Conference on Conditioning Monitoring and Diagnosis (CMD, 212), pp: 446-449. Kraetge, A., M. Kruger, J.L. Velasquez, H. Viljoen and A. Dierks, 29. Aspects of the practical application of Sweep Frequency Response Analysis (SFRA) on power transformers. Proceeding of 6th Southern Africal Regional Conference (CIGRE, 29). Kulkarni, S.V. and G.B. Kumbhar, 27. Analysis of short-circuit performance of split-winding transformer using coupled field-circuit approach. IEEE T. Power Deliver., 22(2): 936-943. Sathya, M.A., A.J. Thomas and S. Usa, 213. Prediction of transformer winding displacement from frequency response characteristics. Proceeding of IEEE 1st International Conference on Condition Assessment Techniques in Electrical Systems (CATCON), pp: 33-37. Wang, F.H., J. Xu, Z.J. Jin and S.S. Gui, 21. Experimental research of vibration sweep frequency response analysis to detect the winding deformation of power transformer. Proceeding of IEEE PES Transmission and Distribution Conference and Exposition, pp: 1-6. Waters, M., 1966. The Short-circuit Strength of Power Transformer. McDonald & Co. Ltd., London. Zhang, Z.W., W.H. Tang, T.Y. Ji and Q.H. Wu, 214. Finite-element modeling for analysis of radial deformations within transformer windings. IEEE T. Power Deliver., 29(5): 2297-235. 295