CHECK LINE INSTRUMENTS. ! Tolerates a wide variation of voltages. ! Immune to electrically noisy environments.

Similar documents
Screens INTRODUCTION OPERATION. Quadrature Counting

TABLE OF CONTENTS WARRANTY

Table of Contents 9.0 WARRANTY. 1.0 Introduction Package Contents. 2.0 Safety Instructions Overview...003

Fits Tiger 320 Series UNIVERSAL FREQ/COUNTER INPUT MODULE

Model 935A. Dual Tone Sender INSTRUCTION MANUAL

Ordering Information. Stepping Relay Unit G9B. Model Number Legend

LINCO MEASUREMENT MODEL CP-2B MASTER METER PROVER COUNTER INSTRUCTION MANUAL

Glass Electrode Meter

MODEL 8080PR3 Released on 11th Mar 2013

34134A AC/DC DMM Current Probe. User s Guide. Publication number April 2009

Instruction Manual Inductive Gauging Sensor

INSTRUMENTS, INC. Model 2960AX Disciplined Quartz Frequency Standard 2960AX. Section Page Contents

C5000 & C5000NF PULSE INITIATOR. Introduction

Instruction Sheet REB SERIES. Rotating Sliding Base REB18

Pre-wired Photomicrosensor with Amplifier and Cable EE-SPW321/421 Compact, Thin-profile Photomicrosensor with special amplifier.

Series 500. Owner s Manual. Analog Transmitters by Data Industrial. Data Industrial. Data Industrial 2/95 PN 72806

Series 3000 Model R-107A

CT-2 and CT-3 Channel Taggers OPERATION MANUAL

2001A. 200KHz Function Generator Instruction Manual. 99 Washington Street Melrose, MA Phone Toll Free

Ordering Information. Ratchet Relay G4Q. Plug-in Models. Model Number Legend

Frequency Calibrator with Totalizer

G7K. Latching Relay. Compact Mechanical Lock Latching Relays with Manual Buttons. Model Number Structure. Ordering Information

E7000, E7500, and E ma Analog Transmitters

JTY2 PULSE DURATION RECEIVER BEFORE USE... COMPONENT IDENTIFICATION

Digital Panel Meter K3TE. Model Number Structure. Model Number Legend. Easy-to-use, Low-cost Digital Panel Meter that Accepts DC Input K3TE

C2000 Operational Manual

Broadband Current Probe Series Operation Manual

WORLD-BEAM QS30 Adjustable-Field Sensors

PIECAL Model 541 Frequency Calibrator with Totalizer Operating Instructions

Instruction Manual Model M Switch, DPDT, Manual Select

MS23SL Magnetic Linear Sensor With Smart Limit Switches

CRD 410 MANUAL FITTING INSERTER

Model 34A. 3Hz to 2MHz 2-Channel Butterworth/Bessel HP, LP, BP, BR Plug-In Filter Card for Model 3905/3916 Chassis.

EC DECLARATION OF CONFORMITY

Precision Frequency To Voltage Converter Card

Model Number Structure

Installation & Operation Manual SAGA1-K Series Industrial Radio Remote Control

INSTALLATION AND MAINTENANCE MANUAL FOR GROUND MONITOR GM-250 COPYRIGHT 1983 AMERICAN MINE RESEARCH, INC.

Broadband Current Probe Series Operation Manual

Frequency Calibrator with Totalizer

G70R-SOC08 CSM_G70R-SOC08_DS_E_2_1

TRIAXIAL FLUXGATE MAGNETOMETER OWNER'S MANUAL

Wilcom MODEL T136BGMZW CIRCUIT TEST SET. Operating Instructions

Sensing method Appearance Sensing distance Operation mode Model Convergent-reflective (narrow vision field) 30 to 100 mm (variable)

BDD-UM 3023 Digital Display

LINCO MEASUREMENT MODEL CP-2BD MASTER METER PROVER COUNTER INSTRUCTION MANUAL

POWER SERIES Plus. Volt / Amp / Hertz. Digital Switchboard Meter. User s Manual IM2493VAF-3

MaxLite LED Self-Driven LiteBars

TL-W5MD1 2M *1 *3 TL-W5MD2 2M

Radio Remote Controls Manual K Series

Check us out on-line! Installation Instructions

Resolution (divisions) Pre-wired Model E6F-AB3C 360P/R 2M *2 Pre-wired Connector E6F-AB3C-C 360P/R 2M *2 Model (2 m) NPN open collector BCD 360

Wilcom MODEL T136BSBZW CIRCUIT TEST SET. Operating Instructions

SL300 Snow Depth Sensor USL300 SNOW DEPTH SENSOR. Revision User Manual

2-wire level transmitter

AC 24, 110, 120, 230, 240 DC 6, 12, 24, 48 LED indicator with test button G2R-1-SNI (S) G2R-2-SNI (S) Diode

model 101 single channel microphone preamplifier owner s manual Rev C

Classic Series Public Address Amplifiers C10 & C20 Models

BC145 SIGNAL ISOLATOR BOARD

HTA125A/250A. Power Amplifiers. Installation & Use Manual

Programmable Universal Frequency Transducer

742A Series Resistance Standards

Fits the Leopard Family FREQ./RPM INPUT MODULE WITH 24 V EXC.

Simplified Operations for TM-3100 Series Digital Tachometer

WORLD-BEAM QS18AFF200 Sensors with Foreground Suppression

Phase-sequence Phase-loss Relay

LT3000 ULTRASONIC LEVEL TRANSMITTER

Instruction Sheet D-CPU. Secure CPU Holder

WEL-200 O P E R A T I N G I N S T R U C T I O N S W I R E L E S S E D G E L I N K

Owner s Manual ODYSSEY BENCH MODEL. O4100B shown REV E. Southern Avenue, Phoenix, AZ USA Workhorseproducts.

An American Control Electronics Brand PCM4 SERIES USER MANUAL PCM4.

AUTOMATION. Operator s Manual. ACF-10 Series Acoustical Flow Sensor for Solids. Rev. 1a, 2/03

MODEL DDS8par 48-bit Binary Parallel Controlled Synthesizer

Copyright 2014 by Minarik Drives

FA401 Single Transmitter / Single Output Receiver. FA401R Single Transmitter / Single Relay Output Receiver. Installation Instructions 02305C

Current Probe Fixture Instruction Manual

MDC VAC Input Brushless Controller. User s Guide. 910 East Orangefair Lane, Anaheim, CA

JMAA-1800HR15. Installation and Operation Instructions. 180w Performance Series Amplifier Kit For Harley RoadGlide/ Ultra

Model Number Structure

41P Portable Calibrator User Manual

USER S MANUAL PROCESS CONTROL MODULE PCM3

8003 1/8 DIN Temperature Controller

ProScale. Compact LCD Readout. Installation & Operation

CCE Image may differ from the actual product By Martin Labbé, eng., Jasmin Goupil & Louis Perreault

ProScale Compact LCD Readout. Operation. Firmware version C 2.xxx and higher

PixController, Inc. Wireless Vibration Sensor For Indoor and Outdoor Use

OPERATION & SERVICE MANUAL FOR FC 110 AC POWER SOURCE

ULT-MVP O P E R A T I N G I N S T R U C T I O N S ULTRALOOP V E HI C L E L O O P DETECTOR Johnston Parkway, Cleveland, Ohio 44128

Document Version 1.2

305 Stimulus Isolator. Description

MDC V, 2A Brushless Controller. User s Guide E. Landon Drive Anaheim, CA

45EMD Portable Calibrator User Manual

SMART Position Sensor, 100 and 180 Arc Configurations

201AP Charge Amplifier User Manual

QuadroMAX. Installation Manual. QM Series. LED Outdoor Lighting Fixtures REV: 3/22/16

User s Guide. Combination Photo-Tachometer Stroboscope Model

K-FACTOR SCALER B & B

Sensing method Appearance Sensing distance Operation mode Model. Emitter E3S-2LE4 Through-beam *1. 2 m. 0.1 to 2 m. 300 mm. 2 m

Current Loop Interface Module M 2025D

Instruction Sheet. VRS Series. Vertical Rackmount system for multiple cable/satellite receivers

Transcription:

Panel Mount Tachometer Model DT-5TG (VDC) CHECK LINE INSTRUMENTS ELECTROMATIC E Q U I P M E N T C O., I N C. 600 Oakland Ave., Cedarhurst, NY 11516 U.S.A. TEL: 516-295-4300 FAX: 516-295-4399 Instruction Manual Features One of the most advanced on the market today, this microprocessor-based panel tachometer not only measures rotational, linear and flow rate speeds, but can also function as an elapsed time counter and ratio meter. By choosing the desired input/output module(s), you can design virtually any system imaginable.! Mounts easily no brackets or screws or any other hardware needed.! Tolerates a wide variation of voltages.! Immune to electrically noisy environments.! Programmable parameters and functions via front panel membrane push-button switches.! Accepts a variety of input and output modules! No need to remember mathematical formulas. Dimensions (mm)! Highly accurate.! Self-testing. Operational Precautions! If the unit is used in a caustic environment, we suggest you use a NEMA 4X enclosure.! Keep unit free of vibration and shock.! When installing unit, keep power and sensor wires separate. Tie cable shield to terminal E (earth ground).! After inserting wires, tighten terminal screws securely.

Specifications Function Display Range Measuring range Update Time Display Time base Accuracy Measuring system Input no. of p/r Input signal characteristics Input signal amplitude Input impedance Voltage output Applicable Sensors Rate Measurement 0.0000 9.9999 0.000 99.999 0.00 999.99 0.0 9999.9 0 99999 Elapsed Time Counter 99.99 sec. 99 min. 59 sec. 99 hours 59 min. 10 99999 rpm (at 1p/r), 0.2 30000 rpm (at 60p/r) 0.25, 0.5, 1, 2, 4, 8, 16 sec., selectable 5-digit LED (0.56" or 14.2 mm high) Controlled by a 4.194304 MHz crystal ±0.008% ± 1 digit CPU controlled 1 9999 (programmable) Sine wave max frequency 10 khz Square wave max frequency 30 khz open collector Contact closure max frequency 20 Hz Sine wave (0.3 30 VP P) Square wave LO: 0 1.5 V, HI 4 30 V 10 k ohms for magnetic pickup, rotary pulse generator and proximity switch only 12 VDC ±5% (50 ma max) to power sensors rotary pulse generator, magnetic pickup, proximity switch, retro-reflective Ambient temperature 32 113 F (0 45 C) Power consumption Voltage requirements Dimensions Weight 1W (5W when using optional modules) 9 35 VDC 3.46"L x 1.88"H x 3.78"W (88L x 48H x 96W mm), includes bezel, fits 1/8 DIN cutout 0.55 lbs (250g) Installation Mounting Unit Our 1/8 DIN case design eliminates the need for brackets and screws for installation. With the tachometer in a level position, insert it into the panel cutout. Gently push the face of the unit until the front bezel locks into place. If the tachometer case is loose, adjust the integral bracket with the enclosed tool. Removing unit From the rear of the tachometer, alternately push the unit from the left and right. This will free it for easy removal. Mounting Bracket Adjustment Panel Thickness Thickness of Panel Adjusting Groove 1.2 1.6 mm 5th groove (factory setting) 1.8 2.5 mm 4th groove 2.8 3.6 mm 3rd groove 4.0 4.5 mm 2nd groove 5.0 mm 1st groove 2

Connections Mode Selections 1&2 DC input terminals. 3 Earth ground. Connect all cable shielding to this terminal. 4 12 VDC 50mA max. This sensor power supply is for any sensor that requires external power 5 Switch closure input. To be used with a relay or solenoid. The input frequency must be less than 20Hz. 6 For use with open collector sensors. Connect the sensor's signal output wire. No need for an external pull-up resistor. 7 Terminal to accept signals from rotary encoders or pulse generators. 8 Standard input terminal for magnetic pick-ups and proximity switches. 9 Signal ground or common. The DT-5TG has five modes of operation. Each mode uses separate parameters for you to program: Mode Function Application 1 Rate measurement Measures rotational (frequency input) linear or flow rate speeds. Factory set. 2 Elapsed time counter Times variable processes. 3 Rate measurement For tachogenerator or voltmeter. Requires input module DOP-VF. 4 Ratio meter Compares two signals in either absolute or percent ratio. Requires input module DOP-RM. 5 Self test Diagnostically tests LED display, panel switches and input circuitry. Sensors Shimpo offers a large selection of sensors to meet you application needs. The chart below shows the optimum sensor to use when designing your system. Please call us for more information. SENSOR RE1B 60C RE1B 600C RE1B 1000C BI2 S12 DJ2 G SE G RS220H MCS 625 3030AN MP 10 3070A* Switch Closure FREQUENCY TYPE Rotary Pulse Generator Proximity Switch Proximity Switch Proximity Gear Sensor Retro Reflective Sensor Magnetic Pick-up TERMINAL NUMBERS 4, 6, 9, 4, 8, 4, 6, 9, 8, 9, 3, 8, 9, 3, 3, 8, 9, FREQUENCY OR RPM RANGE 0 5000 rpm 0 3000 rpm 0 1800 rpm 0 2 KHz 0 1 KHZ 0 8KHz 0 500 Hz 0 250 Hz R elay or Solenoid 5, 9, <20 Hz OPERATION TEMPERATURE +14 F to +122 F +14 F to +122 F +14 F to +122 F -13 F to +158 F -68 F to +140 F -4 F to +158 F +14 F to +140 F -22 F to +120 F -100 F to +225 F -40 F to +221 F -100 F to +200 F * explosion proof 3

Setting Modes 1.Apply any voltage between 9 35 VDC to terminals 1 and 2. When power is applied, the display will show all zeroes. After half a second, the display will change to 0. 2.Press mode and data set keys for at least 5 seconds. A zero will flash until 1 appears on the display. 3.Press the increment key to select the mode you want. Mode sequence will depend on input module 4.Press mode key. You're now ready to program the parameters for the mode you have selected. Setting Parameters Parameter 1: Pulses Per Revolution from Sensor Here's how to change the parameter from 1 to 60 pulses per revolution ("p/r"): 1. Set unit to mode 1. 2. Press mode key. 3. Press shift key to select the desired digit. 4. Press increment key 6 times. 5. Press shift key. Parameter 1 is now set for 60 p/r. 6. Press increment key 9 times. Mode 1: Rate Measurement The DT-5TG can easily measure any rotational, linear or flow rate speed. Each parameter function dictates the necessary steps when preparing a system application. Parameters 2 and 3 can be measured with a hand-held digital tachometer (no need for arithmetic calculations). Parameter Function Setting Factory Range 1 Pulses per revolution 1p/r 1 9999 2 Sensing rpm 50,000 rpm 3 Display units 50,000 rpm (rpm, fpm, ips) 4 Decimal point none 0 4th place 5 Minimum rpm (sensor) 10 rpm 6 Update time 1.25,.5, 1, 2, 4, 8, 16 7 Acceleration 0 0, 1, 2 Parameter 2: Sensing RPM To change the parameter from 50,000 to 1,000 rpm. 1. Press mode key 2. Press shift key 3. Press increment key five times. 4. Press shift key 5. Press increment key. 4

Setting Parameters (cont'd) Parameter 3: Display Units Program this parameter to the desired display value corresponding to the parameter 2 setting. For example, suppose a conveyor is running at 157 fpm and 1,000 rpm sensing speed. This parameter would then be programmed for 157. 2. Press increment and shift keys to change display. To get a decimal point, increase the parameter 3 setting by a power of 10, depending on the number of decimal places needed. For one decimal place (in this example), program the display for 01570. For two places, program 15700. Parameter 7: Acceleration This parameter is useful when rate speeds accelerate or stop rapidly. If the tachometer senses a large rate change, the update time automatically switches to.25 seconds. When the tachometer senses a constant rate, the update time is determined by parameter 6. 1. Press mode key 2. Press shift key to set parameter: 0 = No function 1 = Rapid stop 2 = Acceleration (input frequency must be 7 Hz) Parameter settings are now complete. Press data set key to start measuring. Parameter 4: Decimal Point Parameter 6: Update Time 1.Press mode key (Skip to parameter 5 if you don't want a decimal point). 2.Press shift key to select position of decimal point. Parameter 5: Minimum RPM (sensor) Set this parameter to the highest value possible. 2. Press shift and increment keys to change display. Field Adjustment In the rate measurement mode, parameter 3 can be adjusted without following the parameter sequence. For example, suppose the initial parameter 2 and 3 settings are 50,000 rpm. But during actual measurements, the display shows 3,800 rpm when the sensing speed is 3,500 rpm. The DT-5TG can be quickly adjusted: 1. Press mode and increment keys simultaneously for 5 seconds. 2. Press shift and increment keys to make adjustment. 3. Press data set key you're now ready to measure speed. If the display shows EE-00, the ratio between parameter 2 and 3 is too large. Press data set key and readjust these parameters according to the parameter setting procedure outlined earlier. 2. Press shift key to select update time. 5

Mode 2: Elapsed Time Mode This mode monitors the time of a continuously variable process. Say, for example, a baker wants to know the amount of time needed to bake cookies. By using a stopwatch, he could measure the amount of time it takes at a known speed of the conveyor. Or, the baker could calculate this time by using the distance formula d=vt. By knowing the calculation time (parameter 4) and rpm of the sensing gear (parameter 2), the baker can continuously monitor the time as the process varies. Parameter 1 Function Setting Sensing gear pulses/ revolution Factory 2 Sensing gear rpm 200 3 Time units (=.) 4 Calculation time 02=.00 Range 1 1 9999 (.)=sec/sec (=.)=min/sec or hr/min 5 Update time 1.25,.5, 1, 2, 4, 8, 16 Parameter 3: Time Units Unit symbols: =. hour/minute or minute/second. second/second 2. Press shift key to select units. Parameter 4: Calculation Time 2. Press shift and increment keys to program time calculated. Parameter 1: Sensing Gear Pulses per Revolution This example shows how to change the parameter from 1 to 60 pulses per revolution. 1. Set the unit to mode 2. 2. Press mode key. If the display shows --=.E9, an entry error has been made. Reprogram the unit using the shift and increment keys. Parameter 5: Update Time 2. Press shift key to select update times. 3. Press shift key 4 times. 4. Press increment key 6 times. The parameter settings are now complete. Press data set key to start elapsed time counter. 5. Press shift key. 6. Press increment key 9 times. Parameter 2: Sensing Gear RPM Here's how to change the parameter from 200 to 100 rpm: 6 2. Press shift key 3 times. 3. Press increment key 9 times.

Mode 5: Self Test This mode lets you check the LED display and input circuitry. 1.Press mode and data set keys for five seconds. 2.Press increment key and select mode 5. 3.Press mode key to test display segments and decimal points. 4.Some display functions switches can also be checked. Press these keys to test: MAX MIN PEAK HOLD 5.Press mode key. The display will show 1000 and signal LED will flash. 6.Press data set key. The display will go back to the previous mode of operation. Display Switches & Functions The DT-5TG has seven display functions located above the display. All functions have an LED indicator and all but GO have a membrane switch. Here is a brief description of each function: HI GO LO MAX If the display is equal to or greater than the HI limit setting, the LED will light and a contact will close.* To program, press HI and mode keys for one second. Use the increment and shift keys to set limit. If the display is between the HI and LO settings, the LED will light and a contact will close.* If the display is equal to or less than the low limit setting, the LED will light and a contact will close.* To program, press LO and mode keys for one second. Use increment and shift keys to set limit. The display will hold the average maximum measurement. To program, press MAX and mode keys until LED lights. MIN The display will hold the average minimum measurement. To program, press MIN and mode keys until LED lights. PEAK The display will hold the absolute peak measurement. To program, press mode and PEAK keys until LED lights. HOLD This function will hold the display indefinitely as long as the unit is powered. To program, press mode and HOLD keys until LED lights. *Requires the DOP-CP Triple Relay Output Module. Note:! The HI, GO and LO functions are non volatile and may be reset by programming to zero.! The MAX, MIN, PEAK and HOLD functions must be used separately. These functions may be reset by pressing the data set key or by interrupting power. Error Codes Display Type of Error What to Do EE-00 Parameter setting Press data set key. Enter parameter according to setting range. EE-01 Hi/Lo setting Press data set key. Enter the upper and lower limits. EE-02 Internal setting Press data set key. Interrupt power at terminals 1 and 2. EE-03 Memory recall Press data set key. In sequence, press HI, hold, increment and mode keys. EE-04 Communication Check connections with module. Press data set key. EE-05 error with EE-06 module 7

$$$$$$$$$$$ Available Modules Optional modules are available from Shimpo. Choose any of the following modules no internal hardware modification is required. Module connectors: DOP-1A For single module DOP-2A For dual module Modules: DOP-VF Voltage input DOP-RM Ratio input DOP-SD RS232C/Mitutoyo output DOP-CP Triple relay output DOP-BC BCD output DOP-FV Voltage/current output DOP-PO Parallel output The DT-5TG is available with one, two, or three module connectors. Each type is indicated by its suffix: DT-5TG-0 DT-5TG-1 DT-5TG-2 No connector 1 connector 2 connectors Multiple Modules: In most applications, two modules may be interfaced with the DT-5TG-2. Below are the specific combinations: CP SD PO BC FV VF RM CP!!!!!!! SD!!!!!!! PO!!!!!!! BC!!!!!!! FV!!!! " " " VF!!!! " " " RM!!!! " " "!#available "#can't be combined $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ $$$$$$$$$$$ LIMITED EXPRESS WARRANTY: Shimpo Instruments warrants, to the original purchaser of new products only, that this product shall be free from defects in workmanship and materials under normal use and proper maintenance for one year from the date of original purchase. This warranty shall not be effective if the product has been subject to overload, misuse, negligence, or accident, or if the product has been repaired or altered outside of Shimpo Instruments s authorized control in any respect which in Shimpo Instruments s judgment, adversely affects its condition or operation. DISCLAIMER OF ALL OTHER WARRANTIES: The foregoing warranty constitutes the SOLE AND EXCLUSIVE WARRANTY, and Shimpo Instruments hereby disclaims all other war ranties, expressed, statutory or implied, applicable to the product, including, but not limited to all implied warranties of merchantability and fitness. LIMITATION TION OF REMED Y: Under this warranty, Shimpo Instruments s SOLE OBLIGATION SHALL BE TO REPAIR OR REPLACE the defective product or part, at Shimpo Instr uments s option. Shimpo SHIMPO ONE-YEAR WARRANTY Instruments reserves the right to satisfy warranty obligation in full by reimbursing Buyer for all payments made to Shimpo Instruments, whereupon, title shall pass to Shimpo Instruments upon acceptance of return goods. To obtain warranty service, Purchaser must obtain Shimpo Instruments s authorization before returning the product, properly repackaged, freight pre-paid to Shimpo Instruments. INDEMNIFICATION & LIMITATION OF DAMAGES: Buyer agrees to indemnify and hold Shimpo Instruments harmless from and against all claims and damages imposed upon or incurred arising, directly or indirectly, from Buyer s failure to perform or satisfy any of the terms described herein. In no event shall Shimpo Instruments be liable for injuries of any nature involving the product, including incidental or consequential damages to person or property, any economic loss or loss of use. MERGER CLAUSE: Any statements made by the Seller s representative do not constitute warranties except to the extent that they also appear in writing. This writing constitutes the entire and final expression of the par ties agreement. $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ CHECK LINE INSTRUMENTS ELECTROMATIC E Q U I P M E N T C O., I N C. 600 Oakland Ave., Cedarhurst, NY 11516 U.S.A. TEL: 516-295-4300 FAX: 516-295-4399