Signet 8900 Multi-Parameter Controller

Similar documents
8900 Multi-Parameter Controller

Signet 9950 Dual Channel Transmitter

Dial-type digital bar graph. LEDs for Open Collector, Relays and Warning Indicator

Signet 9950 Dual Channel Transmitter

Signet 9900 Transmitter

Signet 9900 Transmitter

Signet 9900 Transmitter

Signet 9900 Transmitter

Signet 9900 Transmitter

Signet 9900 Transmitter

Signet 2750 DryLoc ph/orp Sensor Electronics

Signet 2751 DryLoc ph/orp Smart Sensor Electronics

+GF+ SIGNET Temperature Transmitter Instructions

Signet Flow Transmitter

Signet ph/orp Electrodes General Purpose

CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal injury.

SIGNET 8860 Dual Channel Conductivity/Resistivity Controller

Signet Conductivity/Resistivity Transmitter

ph/orp Transmitter SIGNET

Conductivity/Resistivity Transmitter

Contents 1. Installation

Signet Conductivity/Resistivity Transmitter

Signet ph/orp Transmitter * *

Analytical Transmitters

Signet ph/orp Electrodes

B850 Boiler House Energy Monitor

* * Signet 2610 Process Optical Dissolved Oxygen Sensor. Operator's Manual. Introduction. English. System Description.

CX105 Conductivity/Resistivity Transmitter

B850 Boiler House Energy Monitor

Signet 2610 Process Optical Dissolved Oxygen Sensor

Model Sono-Trak Transit Time

Digital conductivity transmitter

Analyze IT Single and Dual Input Analyzers for ph/redox (ORP)

High Performance Process & Temperature Controllers

ABB MEASUREMENT & ANALYTICS DATA SHEET. AX410, AX411, AX416, AX450 and AX455 Single and dual input analyzers for low level conductivity

PROCESS & TEMPERATURE CONTROLLERS

Single and Dual Input Analyzers for Low-level Conductivity

Process displays For standard signals, temperature, resistance measurement

JUMO ecotrans Lf 03 Microprocessor Transmitter / Switching Device for conductivity or resistivity and temperature

Conductivity Analyzer

Ultrasonic level transmitter, non-contact

Excellent low-cost Process & Temperature Controllers

ABB MEASUREMENT & ANALYTICS DATA SHEET. AX460, AX466 and AX416 Single and dual input analyzers for ph/redox (ORP)

DP2000 ORDERING GUIDE To Order MODEL NO.

LST400 Ultrasonic level / open channel flow transmitter

The transducer component converts the measured signal and displays the actual value.

AX460, AX466 and AX416 Single and dual input analyzers for ph/redox (ORP)

Advanced, accurate and intelligent monitoring for your transformer

GE Sensing. Introduction. Wiring Diagrams (Typical) Field Calibration. Installing the Sensor

UniStream Built-in. Technical Specifications US7-B5-RA28, US7-B10-RA28 US7-B5-TA30, US7-B10-TA30

EXPERT-LINE. KOBO-pH. Transmitter for ph-value and ORP Model APM-X

Effective: June, 2000 EX-1821 Satellite Display Unit Receiver Installation Manual Models: 4643-*-* 4644-*-9 Since 1937

Advanced Ladder Logic Full IEC Languages 25A for <1 24 VDC DC Switched

Dissolved Oxygen Measurement liquisys M COM 223 F / 253 F

RI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters

Analog outputs (option) Output 1 + 2: 0(4) 20 ma or 0 10 V

ABB MEASUREMENT & ANALYTICS DATA SHEET. Ultrasonic level LST400 Open channel flow transmitter

WATER MADE EASY MARINE ENERGY MUNICIPAL INDUSTRIAL

Viconics VT76x7 Series Rooftop Unit Controllers Engineering Guide Specification

CALYS 50. Field multifunction calibrator for basic use

Signet 9900 Transmitter

DissolvedOxygenMonitor

Isolated, Frequency Input 5B45 / 5B46 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

ZZxD-Nx-xR Series. Wireless Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

MODEL: KS. Plug-in Signal Conditioners K-UNIT

CALYS 75. Field documenting multifunction calibrator

Signet 9900 Transmitter

Portable Multi-Channel Recorder Model DAS240-BAT

High-precision process calibrator Model CED7000

7SD/7SH/7SM Temperature Controllers

Fuzzy Temperature Controllers E5AF

Agilent Technologies 3000 Series Oscilloscopes

Isolated, Linearized Thermocouple Input 7B47 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

CALYS 100. Field precision documenting multifunction calibrator

ph or ORP Transmitter

WaveStation Function/Arbitrary Waveform Generators

MICROFUSION FEATURES OPTIONS CERTIFICATIONS THREE PHASE SCR POWER CONTROLLERS

Isolated, Thermocouple Input 7B37 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

2302 Battery Simulator 2306, 2306-PJ Battery/Charger Simulators

Economical Digital Indicators For Process and Electrical Measurement

ECB-103 BACnet B-ASC 10-Point Programmable Controllers

Solid State Pressure Sensors D8M

Electro-Magnetic Flowmeters COPA-XE

Technical Information RMS621

Technical data. Functional safety related parameters MTTF d. Transfer characteristics. Time delay before availability. Standard conformity

CALYS channels High accuracy calibrator

MULTIFUNCTION GRAPHICAL UNIT MGU 800

UniStream Uni-I/O Modules

N432A Thermistor Power Meter DATA SHEET

INTRODUCING SOME GREAT NEW PRODUCTS FROM OUR DWYER INSTRUMENTS RANGE:

Arbitrary/Function Generator AFG1000 Series Datasheet

- SMART TUNE- PID CONTROL - UNIVERSAL, 3 WIRE- TC, RTD AND LINEAR INPUT - AUX- REMOTE SET POINT/ TRIM INPUT - 2x ISOLATED CONTROL AND RETRANSMISSION

Electro Controls. Input-Output Modules WattsIndustries.co.uk

SITRANS F flowmeters SITRANS F US. SONOFLO SONO 3000 transmitter. 4/152 Siemens FI Overview

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

TECHNICAL DATASHEET #TDAX ISOLATED DUAL CHANNEL UNIVERSAL SIGNAL CONVERTER

Model 332 Temperature Controller

UniStream 5" Technical Specifications US5-B5-RA28, US5-B10-RA28

CALYS 150. Advanced documenting multifunction calibrator thermometer

USB-TEMP and TC Series USB-Based Temperature Measurement Devices

Transcription:

Signet 8900 Multi-Parameter Controller Member of the ProcessPro Family of Instruments Features Measures Flow, ph, ORP, Conductivity, Pressure, Level and Temperature Multi-language display ¼ DIN enclosure Up to analog outputs Up to 8 relays 12 to 2 VDC or 100 to 20 VAC ±10%, regulated power Digital communication allows for extended cable lengths and easy wiring Accepts rd party to 20 ma output devices when used with 808 signal converter The Signet 8900 Multi-Parameter Controller takes the concept of modularity to the extreme. Each 8900 is field commissioned with the users specified combination of inputs, outputs, and relays using simple-to-install modular boards into the base unit. Configure the system by selecting either two, four, or six input channels which accepts any of the Signet sensors listed below, and/or other manufacturer s sensors via a to 20 ma signal converter (Signet Model 808). To complete your unit, choose a power module with universal AC line voltage or 12 to 2 VDC ±10%, regulated. If more features are needed, analog output and relay modules are available and easily installed. Plus, the 8900 will support four additional relays via an external relay module. There are other notable features that the 8900 offers. For instance, digital input to the 8900 enables longer cable runs and simplified wiring with minimal noise interference. Advanced relay logic allows users to select up to measurement sources to trigger 1 relay. Derived measurements include difference, sum, ratio, percent recovery, percent rejection, percent passage and BTU. The menu system can be programmed to display in multi-languages including English, German, French, Spanish, Italian, and Portuguese. Available with 2 to 6 channels Simultaneous BTU Calculations with Heating & Cooling Totalizers per calculation MEASURING EQUIPMENT 77CJ Applications RO/DI System Control Media Filtration Pure Water Production Demineralizers Chemical Processing Metal & Plastics Finishing Fume Scrubbers Proportional Chemical Addition Cooling Tower & Boiler Protection Wastewater Treatment Aquatic Animal Life Support Systems Rinse Tank

Specifications General Compatibility Modular (completely field-commissionable) No. of Input Channels 2,, or 6 Compatible Sensors See System Overview Input Signal Types Digital (S L) Serial ASCII, TTL level 9600 bps Frequency 0.% of reading Measurement Types Flow, ph, ORP, Conductivity/Resistivity, Pressure, Temperature, Level, or rd party devices with a to 20 ma output Derived Measurements Sum, difference, ratio, % recovery, % reject, % passage, power (BTU) No. of Relays Supported Available: 2,, 6 or 8 (8 dry-contact or solid state and dry- contact) No. of Analog Outputs Available in pairs: 2 or (active and/or passive to 20 ma); and/or 2 (0 to /10 VDC) Enclosure and Display Enclosure Rating NEMA X/IP6 (front face only) Case Material PBT Panel Gasket Silicone Sponge Window Self-healing polyurethane-coated polycarbonate Keypad -buttons, highly tactile and audible injection-molded silicone rubber seal Display Alphanumeric 2 x 16 back-lit LCD Update Rate 1 second Accuracy Sensor dependent LCD Contrast settings Languages Available English, French, Spanish, German, Italian and Portuguese Display Ranges (see sensor specifications for actual measurement limits) ph -2.00 to 1.00 ph ph Temperature -0 C to 10 C -0 F to 02 F ORP -9999 to +9999 mv Flow Rate 0.0000 to 999999 units per second, minute, hour or day Totalizer 0.00 to 99999999 units Conductivity 0.0000 to 999999 μs, ms, PPM & PPB (TDS), kω, MΩ Conductivity Temperature -99.9 C to 20 C -18 F to 82 F Temperature -99.9 C to 999.9 C -18 F to 999.9 F Pressure -99.99 to 9999 psi, kpa, bar Level -99999 to 99999 m, cm, ft, in., % Volume -99999 to 999999 m, ft, in, cm, gal, L, kg, lb, % Other ( to 20 ma) -99999 to 999999 user selectable units Environmental Ambient Operating Temperature Backlit LCD -10 C to C 1 F to 11 F Storage Temperature -1 C to 80 C F to 176 F Relative Humidity 0 to 9%, non-condensing Maximum Altitude 2,000 m (6,60 ft),000 m (1,12 ft); use only DC power supply and, if applicable, solid state relays to maintain UL safety standard up to this altitude

Specifications (continued) Electrical Power Requirements (AC or DC via Power Modules) Universal AC 100 to 20 VAC ±10%, regulated 0-60 Hz, 2 VA max. DC 12 to 2 VDC, ±10%, regulated recommended, 7 Watts max. Output Power to Sensors VDC up to 0 ma total Terminal type Screw-clamp, removable via plug-in modules Analog Outputs (via I/O Modules and Output Modules) All analog outputs are freely assignable to any channel. to 20 ma Output Endpoints are adjustable and reversible Minimum Default.0 ma; user adjustable from.8 to.0 ma Maximum Default 20.00 ma; user adjustable from 19.0 to 21.0 ma Test Mode Produces an adjustable to 20 ma signal for functional verification of each output circuit Isolation Up to 8 VAC/DC Error Condition 22.1 ma (default state when output source not configured) Update Rate 100 ms Accuracy ±2 μa over entire operating temperature range Passive to 20 ma Voltage 12 to 2 VDC, ±10%, regulated Max. Impedance 20 Ω @ 12 VDC 00 Ω @ 18 VDC 70 Ω @ 2 VDC Active to 20 ma Max. Impedance 70 Ω 0 to /10 VDC Output Endpoints are adjustable and reversible Output Range 0 to VDC or 0 to 10 VDC, software selectable Minimum Default 0 VDC; user programmable from 0 to 0. VDC Maximum Default VDC; user programmable from. to. VDC, or 9. to 10. VDC Output Load 10 kω minimum Test Mode Produces an adjustable signal for functional verification of each output circuit Isolation Up to 8 VAC/DC Error Condition 0 VDC (default state when output source not configured) Update Rate 100 ms Accuracy ±20 mv over entire operating temperature range Resolution mv Power Supply Rejection 0. mv/v Relay Modules All relays are freely assignable to any channel. Internal relay modes of operation Off, Low, High, Window, Proportional Pulse, Pulse Width Modulation, USP, Volumetric, Pulse, Totalizer Volume, Advanced, % Rejection, % Recovery, % Passage External relay modes of operation Off, Low, High, Window, USP, Totalizer Volume, Advanced, % Rejection, % Recovery, % Passage Hysteresis User adjustable Time Delay 0 to 600 seconds Advanced Relay Use AND/OR logic along with relay sources to trigger a relay. High/Low modes available for each of the sources Solid State Relays Non-mechanical switches Normally Open/Closed Operation Software selectable

Specifications (continued) Relay Modules continued Maximum Voltage Rating 0 VDC or 2 VAC p-p Current Rating 0 ma DC or 0 ma AC RMS On-state Impedance 0 Ω or less Off-state Leakage 00 na or less, AC or DC Isolation Up to 8 VAC/DC Transient Protection Embedded, up to 8 V over-voltage Dry-contact Relays Mechanical contacts Type SPDT Form C Maximum Pulse Rate 600 pulses/min. (volumetric pulse & PWM modes) 00 pulses/min. (prop. pulse mode) Maximum Voltage Rating 0 VDC or 20 VAC Current Rating A Shipping Weight Base Unit 1.00 kg 2.2 lb Power Module 0.12 kg 0.2 lb I/O Module 0.12 kg 0.2 lb Output Module 0.12 kg 0.2 lb Relay Module 0.12 kg 0.2 lb Standards and Approvals CE, UL, FCC RoHS compliant, China RoHS Manufactured under ISO 9001 for Quality, ISO 1001 for Environmental Management and OHSAS 18001 for Occupational Health and Safety. Dimensions 96 mm (.78 in.) Signet Multi-Parameter Controller 96 mm (.78 in.) 96 mm (.78 in.) Optional Rear Cover 92 mm (.6 in.) 12 mm (.8 in.) 6 mm (2.21 in.)

Panel Mount Signet 8900 Multi-Parameter Controller POWER RELAY 2 RELAY 1 RELAY RELAY SEN SOR I N P UTS OUT 2 OUT 1 Input/ Output Controller 2 Outputs Relay Signet Signal Converter/ Relay Module 808 809 Signet Sensors Use up to 6 inputs with one instrument from a choice of sensors 1 2 2000 2100 220 20 20 207 26 27 20 21 22 270 280 RELAY A N/C 7 8 GND 9 ta 8 Data V /C 6 N/C Loop22 - S L Ou tput COM Loop22 + /C N/C 7 2 Data 1 Loop1 + SIGNET Loop -20 ma Input rrentt Input -808-2 Cu rre Loop1 2 Loop1 - NET POWER INPUT SL RELAY C - Relay A Relay B Test C Relay C PASS-THRU + SL RELAY D Test A Test B Relay D Test D LISTED E1719 + RELAY B Signet -809 Relay Module SIG 1 6 2 System Overview Power COM M PORT/ O UT O UT Select from a choice of boards - DC OUTPUT + - DC INPUT - + 9 10 Turbidimeter FLOW 2610 Dissolved Oxygen Sensor Signet Fittings - See individual sensor data sheets All sold separately There are hundreds of system types that can be set up with the 8900. The examples below illustrate various sensors in different installation schemes. Wiring topology for point-to-point, daisy-chain, multi-drop, or a combination of these are listed in each example. Digital sensor outputs allow for long cable runs with high noise immunity. See Wiring section for allowable cable lengths. Example 1 8900 input module: Two inputs Sensors connected: Signet 270 with 272 ph sensors and 20 flow (frequency) Wiring configuration: Point-to-point C1 2.0 µs/cm F2 8. GPM Multi-Parameter Controller Relay 2 Relay 1 ENTER 8900 270 Notes 1. External relays can be used with any input module and does not consume a sensor input channel (Model 809) 2. Model 808 Signal Converter can be used with any input module Example 2 8900 input module: Four inputs Sensors connected: Signet 20 temperature sensor, 280 with 281 conductivity, and two 20 pressure sensors Wiring configuration: Daisy-chain 272 20 ph Flow C1 2.0 µs/cm F2 8. GPM Multi-Parameter Controller Relay 2 Relay 1 ENTER 8900 280 281 20 Temperature 20 Pressure 20 Pressure Conductivity

FLOW Relay 2 ENTER Relay 1 Relay 2 ENTER NC C NO NC C NO RELAY A RELAY B Signet -809 Relay Module LISTED E1719 COM POWER INPUT PASS-THRU + S L - + S L - Test A Test B Test C Test D NC C NO NC C NO RELAY C RELAY D OUTPUT 2VDC + - Relay A Relay B Relay C Relay D AC INPUT L N SIGNET 2 1 6 Loop1 PWR Loop2 PWR S L DATA N/C 7 8 9-20 ma Input S L Output N/C 6 Loop2 - N/C Loop1-2 Loop1 + 1 VDC MAX Loop2+ 7 +VDC 8 S L 9 GND -808.610B Example 8900 input module: Four inputs Sensors connected: Signet 207 flow (frequency) and 270 with 272 ph sensors; Other manufacturers' dissolved oxygen and level sensors with to 20 ma output External Devices: Signet 808 signal converter - to 20 ma to digital (S L) Wiring configuration: Combination of point-to-point and daisy-chain 207 Flow 8900 C1 2.0 µs/cm F2 8. GPM Multi-Parameter Controller 270 272 ph 808 Signal Converter 808-20 ma to S L Converter Specific ion sensor (example of other brand) Generic to 20 ma output sensor (Fully configurable display for any units) Example 8900 input module: Six inputs Sensors connected: Signet 20 temperature sensor, 280 with 280 conductivity, 20 pressure, 270 with 272 ph, and 1 and 26 flow (frequency) sensors External Devices: Signet 809 external relay module Wiring configuration: Combination of point-topoint and Multi-drop 1 26 Flow Flow C1 2.0 µs/cm F2 8. GPM Multi-Parameter Controller 8900 809 External Relay 280 280 Conductivity 270 272 ph 20 Temperature 20 Pressure Wiring Options Point-to-point wiring is direct wiring of individual devices into the controller. This wiring topology is applicable for all inputs. Daisy-chain wiring allows sequential connection from one device to the next by using junction boxes. This wiring topology is applicable for digital (S L) inputs only. Multi-drop wiring allows drops from a single bus cable. Junction boxes can be used for the -way junctions that are formed with this wiring scheme. This wiring topology is applicable for digital (S L) inputs only. Please refer to Wiring, Installation, and Accessories sections for more information.

POWER COMM PORT/ Installation of Modules with the base unit -8900 One base unit is required to build a functional 8900. It is offered with a backlit LCD display. Programming the unit is done simply via the push-button keypad. The unit can be tailored to display in English, German, French, Spanish, Italian, and Portuguese. The two line display allows for easy programming, navigation, and viewing of each channel. 1. I/O module One I/O module is required to build a functional 8900. I/O modules are offered for 2,, or 6 sensor inputs with or without two ma or voltage outputs. Users can select two additional outputs via the output module. 2. Power module One power module is required to build a functional 8900. The power module is offered for universal 100/20 VAC or 12 to 2 VDC (This module can be powered by optional external relays (see ordering information for more details).. Output module Output modules are optional when building an 8900. This module can be used in addition to other outputs that are available in the I/O modules. Active current are powered by the 8900. Passive outputs require an external 12 to 2 VDC power supply. All outputs are assignable to any input channel. 1-8900.01-X 2-8900.02-X -8900.0-X 1 OUT 2 OUT 1 SENSOR INPUTS -8900.0-1 -8900.0-2 OUT OUT -8900 2 RELAY RELAY RELAY 2 RELAY 1 & Relay modules Relay modules are optional when building an 8900. Relay modes of operation include off, low, high, window, USP, totalizer volume, advanced, proportional pulse, pulse width modulation, volumetric pulse, % reject, % recovery and % passage. The advanced relay option for AND/OR logic is used for up to conditions. For instance, a relay will go to high/low if a is true and b or c is false. One or two relay modules can be installed into the 8900. One additional external relay module can also be used at the same time (See optional external relay ordering information.) All relays are assignable to any input channel. Installation of Modules: Modules simply plug in by sliding into the base unit on rails. They are held securely in place by the rear cover. Changes and upgrades can be made in the field at any time. Ordering Notes 1) Building a functional unit requires a base unit, I/O module, and power module. 2) Output options are available on I/O modules and additional output modules can be used. The 8900 can support up to four outputs. ) The 8900 can support up to eight relays. Up to two internal relay modules can be used simultaneously; additional external relays can also be used. ) A maximum total of two frequency sensors can be used with any input card. ) A total of six digit inputs or four digital inputs with two frequency inputs can be used. 6) The 8900 boards are field replaceable. 7) The 8900 can be reconfigured with new sensor types by simple reprogramming.

LISTED E1719 DC INPUT Ordering Information To build a functional 8900 controller, choose the base unit, power module, and input/output (I/O) module. Additional outputs and relays are available, if needed. RELAY A Relay 1 Relay 2 RELAY B RELAY C Test A Relay A Signet -809 Relay Module COM Test B Relay B Test C Relay C Test D Relay D RELAY D Base Units, Required -8900 19 000 868 Base unit with back-lit LCD I/O (input/output) Modules, Required; Choose One -8900.01-1 19 000 870 Dual (2) Input (no outputs) -8900.01-2 19 000 871 Dual (2) Input with Two Passive* Loop Outputs -8900.01-19 000 872 Dual (2) Input with Two Active Loop Outputs -8900.01-19 000 87 Dual (2) Input with Two Voltage Outputs -8900.01-19 000 87 Quad () Input (no outputs) -8900.01-6 19 000 87 Quad () Input with Two Passive* Loop Outputs -8900.01-7 19 000 876 Quad () Input with Two Active Loop Outputs -8900.01-8 19 000 877 Quad () Input with Two Voltage Outputs -8900.01-9 19 000 968 Six Inputs (no outputs) -8900.01-10 19 000 969 Six Inputs with Two Passive* Loop Outputs -8900.01-11 19 000 970 Six Inputs with Two Active Loop Outputs -8900.01-12 19 000 971 Six Inputs with Two Voltage Outputs Power Modules, Required; Choose One -8900.02-1 19 000 878 110/220 VAC Power Module, ±10%, regulated -8900.02-2 19 000 879 12 to 2 VDC Power Module, ±10%, regulated Optional Output Modules - Choose One -8900.0-1 19 000 88 Two Passive* Current Loop Outputs -8900.0-2 19 000 88 Two Active Current Loop Outputs Optional Relay Modules - Choose One or Two -8900.0-1 19 000 880 Two Dry Contact Relays -8900.0-2 19 000 881 Two Solid State Relays Optional External Relays - Choose One** -809-19 000 772 Four dry-contact relays; requires 12 to 2 VDC ±10%, regulated -809-AC 19 000 77 Four dry-contact relays; requires 100 to 20 VAC ±10%, regulated; supplies power to the 12 to 2 VDC ±10%, regulated power host device INPUT PASS-THRU + S L - + S L - DC OUTPUT + - - + * Passive outputs require an external power source ** See individual product page for the 809 External Relay Modules. Accessories and Replacement Parts Mfr. Part No. Code Description Mounting -800.92 19 000 60 ¼ DIN retrofit adapter -800.9 19 000 186 Splashproof rear cover -0000.96-1 19 000 892 ¼ DIN wall mount bracket, 6½ in. (use if no rear cover is installed) -0000.96-2 19 000 89 ¼ DIN wall mount bracket, 9 in. (use if rear cover is installed) -000.99 198 80 22 Panel adapter, x in. to ¼ DIN -000.98 198 80 22 Surface mount bracket -9900.96 19 001 701 Angle adjustment adapter kit Power Supplies 710-102 19 87 00 2 VDC Power Supply, 10W, 0.2 A, 710-202 19 87 00 2 VDC Power Supply, 2W, 1.0 A 710-02 19 87 006 2 VDC Power Supply, 0W, 1.7 A 710-602 19 87 007 2 VDC Power Supply, 60W, 2. A 710-702 19 87 008 2 VDC Power Supply, 96W,.0 A Miscellaneous -800.96 19 000 617 RC filter kit (for relay use), 2 per kit -8900.099 Rev E (/1) Georg Fischer Signet LLC 01 Aero Jet Avenue, El Monte, CA 9171-2882 U.S.A. Tel. (626) 71-2770 Fax (626) 7-207 e-mail: signet.ps@georgfischer.com Specifications subject to change without notice. All rights reserved. All corporate names and trademarks stated herein are the property of their respective companies.