Version 1.0. TechnicVR. Student Guide

Similar documents
Beam-Restricting Devices

Mammography is a radiographic procedure specially designed for detecting breast pathology Approximately 1 woman in 8 will develop breast cancer over

X-RAYS - NO UNAUTHORISED ENTRY

Ansur TNT Users Manual. Plug-In

Distributed by. Ecotron Anyview Series. The Intelligent C-Arm System

SPRINGFIELD TECHNICAL COMMUNITY COLLEGE ACADEMIC AFFAIRS

I. PERFORMANCE OF X-RAY PRODUCTION COMPONENTS FLUOROSCOPIC ACCEPTANCE TESTING: TEST PROCEDURES & PERFORMANCE CRITERIA

X-ray Tube and Generator Basic principles and construction

X-ray Imaging. PHYS Lecture. Carlos Vinhais. Departamento de Física Instituto Superior de Engenharia do Porto

DENTAL RADIOGRAPHY KAMARUL AMIN BIN ABU BAKAR

CIRCLEX 0.3/0.8P324&0.6/1.2P324DK-85

DISC QC/QA Program for Digital Imaging Systems using the DR Radchex Plus Meter

X-rays. X-rays are produced when electrons are accelerated and collide with a target. X-rays are sometimes characterized by the generating voltage

Dose Reduction and Image Preservation After the Introduction of a 0.1 mm Cu Filter into the LODOX Statscan unit above 110 kvp

SPECIFICATION. Kilovoltage X-ray calibration system for protection and diagnostic level dosimetry. Prepared by

Introduction. Chapter 16 Diagnostic Radiology. Primary radiological image. Primary radiological image

Interventional Radiological Equipment selection and installation

Nuclear Associates

Nuclear Associates

Key words: fluoroscopy, dose-area-product, kerma-area-product, calibration of KAP meters, patient exposure

X-RAY IMAGING EE 472 F2017. Prof. Yasser Mostafa Kadah

Multiple Choice Identify the letter of the choice that best completes the statement or answers the question.

Digital radiography. bucky table and wall stand as a dual detector or wireless system. Amadeo DR Systems

Exposure System Selection

Calculati tions - BIR meth thod and NCRP 147

Teaching Digital Radiography and Fluoroscopic Radiation Protection

siemens.com/luminos-fusion Luminos Fusion The 2-in-1 system that fits your needs and fits your budget

R&F X-ray systsem. Savings With Every Exposure

RADIOGRAPHIC EXPOSURE

2012 :15th SESSION of ESMP

C506-E064. Full digital system. Printed in Japan A-NS

MXHF-1500RF is controlled by Digital key panel console that displays KV, ma and mas with APR menu programmed.

Dosepix Detector as kvp-meter in Radiology and Mammography: First steps

COMPUTED RADIOGRAPHY CHAPTER 4 EFFECTIVE USE OF CR

Nuclear Associates

YSF - 300/DAR i

Joint ICTP/IAEA Advanced School on Dosimetry in Diagnostic Radiology and its Clinical Implementation May 2009

Test Equipment for Radiology and CT Quality Control Contents

China Resources Wandong Medical Equipment Co., Ltd. High Frequency 50kW, 150kV Radiography System - HF50-R

RULES OF TENNESSEE DEPARTMENT OF ENVIRONMENT AND CONSERVATION DIVISION OF RADIOLOGICAL HEALTH CHAPTER USE OF X-RAY APPARATUS

Philips XPER FD10C R7.0.4

USER MANUAL. RaySafe X2. RaySafe X2 Solo

1. Carlton, Richard R., and Arlene M. Adler. Principles of Radiographic Imaging: An Art and a Science, 5th edition (2013).

QUALITY CONTROL TESTS IN SOME DIAGNOSTIC X-RAY UNITS IN BANGLADESH

Investigation of Effective DQE (edqe) parameters for a flat panel detector

Ch. 223 VETERINARY MEDICINE CHAPTER 223. VETERINARY MEDICINE GENERAL PROVISIONS X-RAYS RADIOACTIVE MATERIAL. Authority

ELECTRONIC CONTROL CONCEPTS 160 Partition Street Saugerties, NY or local phone

X-ray Tube and Generator Basic principles and construction

SONIALVISION G4 Multi-purpose Digital R/F System C506-E075

SONIALVISION G4 Multi-purpose Digital R/F System C506-E075

Product data Remote Controlled Table

Step By Step Guide PA Hand This tutorial will take you through the following steps.

APPLICATION NOTE. RTI Electronics AB, Sweden Revision A, July kvp and time measurements with the Barracuda or Piranha on a typical dental unit

Step By Step Guide AP Supine Abdomen (Table bucky example) This tutorial will take you through the following steps.

Some operation methods show in the catalog reguire optional eguipment

Contrast. Contrast: the difference in density on adjacent areas of a radiograph or other image receptor. Subjective. Long Scale (Low Contrast)

SONIALVISION G4 Multi-purpose Digital R/F System

Overview. Professor Roentgen was a Physicist!!! The Physics of Radiation Oncology X-ray Imaging

AeroDR X60. Motorized X-ray System

SYLLABUS. TITLE: Equipment Operation I. DEPARTMENT: Radiologic Technology

The importance of radiation quality for optimisation in radiology

Half value layer and AEC receptor dose compliance survey in Estonia

ACCU-GOLD QUICK START MANUAL

Quality imaging, practical investment. Philips DuraDiagnost specifications

Nuclear Associates

Exposure in Dental Radiology: A Comparison Between Intra-oral, Panoramic and Tomographic Examinations

Enhanced Functionality of High-Speed Image Processing Engine SUREengine PRO. Sharpness (spatial resolution) Graininess (noise intensity)

Truly flexible to meet your clinical needs

C501-E029C. RADspeed. GENERAL RADIOGRAPHIC SYSTEM Automatic

Mammography: Physics of Imaging

Intraoral X-Ray For Film and Digital Systems

ECOVIEW 9 / ECOVIEW 9 PLUS Digital Radiographic System

ProX Intraoral X-ray. PLANMECA is proud to introduce a new intraoral X-ray unit to its comprehensive collection of imaging products- the ProX.

HISTORY. CT Physics with an Emphasis on Application in Thoracic and Cardiac Imaging SUNDAY. Shawn D. Teague, MD

Digital Imaging started in the 1972 with Digital subtraction angiography Clinical digital imaging was employed from the 1980 ~ 37 years ago Amount of

REQUIREMENTS FOR LICENCE HOLDERS WITH RESPECT TO QUALITY CONTROL TESTS FOR DIAGNOSTIC X-RAY IMAGING SYSTEMS

Nuclear Associates

Outline. Digital Radiography. Understanding Digital Modalities: Image Quality and Dose. Image Quality. Dose Control

LECTURE 1 The Radiographic Image

QC in Diagnostic Radiology. Main steps for a QC survey in Diagnostic Radiology

X-RAY FLUOROSCOPY IMAGING SYSTEMS. Dr Slavik Tabakov. Luminescence: Dept. Medical Eng. & Physics King s College London

P R E S E N T E D B Y. K A M A R U L A M I N A B D U L L A H Dip. MED. IMG., BSc. MED. IMG. (UiTM)

The Evaluation of Collimator Alignment of Diagnostic X-ray Tube Using Computed Radiography System

ECOVIEW 9 / ECOVIEW 9 PLUS Digital Radiographic System

3/31/2011. Objectives. Emory University. Historical Development. Historical Development. Historical Development

NATIONWIDE EVALUATION OF X-RAY TRENDS (NEXT) TABULATION AND GRAPHICAL SUMMARY OF THE 1999 DENTAL RADIOGRAPHY SURVEY

Do you have any other questions? Please call us at (Toll Free) or , or

Veterinary Science Preparatory Training for the Veterinary Assistant. Floron C. Faries, Jr., DVM, MS

Unfors EDD-30 Radiation Protection in Fluoroscopy

Distributed source x-ray tube technology for tomosynthesis imaging

Luminos RF Classic. Where value meets performance.

BASICS OF FLUOROSCOPY

RAD 150 RADIOLOGIC EXPOSURE TECHNIQUE II

X-ray Imaging (XRI) Lectures on Medical Biophysics. Dept. Biophysics, Medical Faculty, Masaryk University in Brno. X-ray Imaging (XRI)

Collimation Assessment Using GAFCHROMIC XR-M2

VISION V FLOOR MOUNTED ТUBE SYSTEM

TEP Principles of Digital X-ray Imaging

Corsix R 32 Accu PRODUCT DATA

MUSICA Nerve Center. Artificial Intelligence. Intelligent tools for your Digital Radiography workflow. Fluoroscopy. Workflow Optimization

Overview of Safety Code 35

Transcription:

Version 1.0 TechnicVR s h a d e r w a r e. c o m Student Guide

TechnicVR s h a d e r w a r e. c o m Student Guide shaderware 2008 PO Box 103 Saltburn Cleveland TS12 1WP w w w. s h a d e r w a r e. c o m info@shaderware.com

Table of Contents Table of Contents 2 Introduction 3 StartingTechnicVR 4 Default start-up screen 4 The view menu 4 The simulated x-ray spectrum 6 Resizing the graph 7 Exporting the graph or spectrum data 8 The detector(s) 9 The entrance surface detector 9 The tube loadings 11 Heat management 11 Predicted filament and anode loadings 12 Selecting procedures and equipment 13 Selecting procedures 13 Equipment Choice 14 Altering common exposure factors 15 Filament size 15 Two or three point control 15 Dental 16 Fluoroscopy and fluorography 16 Bibliography 17

Introduction This section will explain what virtual radiography is This software is used to support radiography students in learning about the x-ray machines used in projection radiography, mammography and fluoroscopy. TechnicVR is a fully featured simulation of the x-rays created during an exposure. It is important to find out about what the patient is subject to. As a practitioner, your patients might ask you questions about this, and you need to be able to alter the factors sensibly to get the right results every time. All types of projection radiographic procedure are possible to set up using TechnicVR. It can be quite rewarding to quickly experiment with extreme examples (without risking equipment or yourselves!). The main benefit is that you can work through this at your own pace, satisfying your own curiosity, wherever a laptop computer can be located. 3

Chapter 1 Starting TechnicVR This section will explain how to start TechnicVR from the desktop or start menu and help you identify the initial screen items. Default start-up screen TechnicVR initially starts with the Procedure tab open and the spectrum graph prominently displayed. The right hand output panel is deliberately hidden by default. The view menu By default, the start-up screen is uncluttered and simple. Any changes to the exposure factors result in a simple outcome changes to the shape and height of the graph representing the beam spectrum. 4

It is easy to customise the screen by altering configurations in the View menu De-select Hide All, you can then choose Beam Characteristics, Heat Management or Dose Area Product. The screen can display all of these outputs at once if required; the Beam Characteristics and Dose Area Product outputs can be further customised. The right hand panel displayed with Beam Characteristics, Heat Management and Dose Area Product all selected. In this example all possible options are selected. 5

Chapter 2 The simulated x-ray spectrum This section will explain the simulated x-ray beam and the quantitative measurements related to the spectrum displayed. The main graphic output from TechnicVR is the simulated x-ray spectrum. This alters in real time with the exposure factors selected. There are also a range of quantitative values associated with this spectrum that are reported and Beam Characteristics. The spectrum graph The graph responds to all exposure factors. It is always displaying photon fluence (the number of x-ray photons per mm 2 ) against photon energy (units of kev) The predicted spectrum is always shown; this allows a dynamic display of any alteration in exposure factor which is a very powerful learning tool. Once the settings have been finalised for any given procedure, the exposure button can be depressed and the spectrum is fixed (if persist option is selected). Changes to the exposure factors will now create a new predicted spectrum; this makes it easy to compare and changes to the original exposure. 6

Resizing the graph The axes are fixed, which allows direct comparison between the spectra. If the new spectrum is too large or too small to be displayed, the axes can be rescaled using the sliders manually or the Autoscale button (AS) 7

Exporting the graph or spectrum data TechnicVR makes it easy to create copyright free content for your PowerPoint presentations, essays or projects. The graph, or the data behind it can be exported from the file menu. TIP: To quickly save a graph, right click on the plot area and a save file dialogue will appear. The data table used to create the graph is saved (File\Save) as a comma separated variable file (.csv) which is compatible with most spreadsheet programmes, e.g. Microsoft Excel. All the beam characteristics (even those that are not currently displayed) and the current exposure parameters are saved to this file alongside the individual photon energy data. 8

Chapter 3 The detector(s) This section will explain the TechnicVR detectors and the controls available on the Detector tab Types of Detector Chapter 2 described how the outputs from the detectors modelled by TechnicVR can be displayed to the user. The Detector tab has options to select the entrance surface detector position and to alter collimation of the beam (which will alter the Dose Area Product reading. The entrance surface detector This is notionally a small device that can be positioned on the entrance surface of a patient or phantom. It might be envisaged as a thermoluminescent material or a solid state device, however it is considered it is of a small size. By altering the Source Image Distance (SID) and the patient thickness, the Source Detector Distance (SDD) can be calculated (remember to add 8-12cm to the patient thickness for Bucky examinations) By default the detector is positioned at the central ray. But its location across the radiation field from cathode to anode can be altered. This will affect the spectrum and beam characteristics reported. 9

The range the detector can be moved is determined by the collimated area, and is reported in degrees. This allows demonstration of the Anode Heel Effect dynamically to students. The Dose Area Product (DAP) meter Modern radiography equipment often has a DAP meter attached to the light beam diaphragm (LBD). This provides a measure of both the ionisation of air due to the intensity of the radiation AND the area irradiated. Two readouts are possible, a predicted value and an accumulated DAP, for fluoroscopy systems. Two sliders are available to alter the collimated area for most procedures; the intra oral dental equipment has a circular collimator with only one slider. 10

Chapter 4 The tube loadings The x-ray spectrum generated by a set of technical factors is only half the story and TechnicVR also simulates the effects the Radiographers settings have on the tube. Heat management Only a small fraction of the electrical energy supplied by the generator is converted into x-rays; the majority heats up the anode target. The type of exposure and tube design all affect the rating of the tube. All these factors are used in the simulation, to achieve very realistic temperature values. These are put into the context of the tube heat capacity and are also shown as % tube loadings or temperatures on degrees Celsius. Once the exposure button is depressed (on the Exposure tab) the heat is applied to the anode and dynamic cooling occurs, in real time, showing the effect of repeat exposures. If a new simulation is required, the tube can be reset to either cold (0%) warm (70%) or hot (100%) by clicking on the appropriate button 11

Predicted filament and anode loadings Most x-ray tubes fail due to filament breakage. Even a small increase in filament temperature can shorten the life of the x-ray tube. TechnicVR will allow overload conditions to be simulated, and the effects are shown. The filament and anode predicted loadings are only displayed on the exposure tab. 12

Chapter 5 Selecting procedures and equipment This section will explain how to select a procedure and make changes to the default exposure parameters Selecting procedures Projection radiography includes a wide range of practice. The equipment used can vary enormously form one procedure to the next. To allow comparisons and accurate simulation, TechnicVR includes the following procedure types to be selected. Dental Intraoral Mobile Chest General room Bariums Angiography Mobile II Mammography The procedure choices will only be displayed when the procedure tab is selected. When a procedure is selected, default exposure factors populate all the fields. These can then be altered individually. 13

Equipment Choice Radiographers have to be flexible enough to carry out procedures on a variety of different equipment. There are often both modern and older x-ray rooms in use at a particular clinic, for example. Different manufacturer s equipment may also have some characteristics that affect the x-ray spectrum. In TechnicVR you can make changes to equipment to show how these affect the x-ray spectrum. These factors are not normally in the control of the radiographer in day to day operation (unless they select to use a particular room). Control of exposure factors can either be by kvp and mas (2 point) or kvp, ma and time (3 point). Changes here will affect the exposure tab layout The equipment choices will only be displayed when the equipment tab is selected. 14

Chapter 6 Altering common exposure factors This is an everyday activity. Although the use of automatically programmed radiography factors (APR) is increasing with modern generator control panels, it is important to optimise exposure factors fr each and every patient. These controls are found on the Exposure tab Filament size A smaller filament size is desirable for improved image quality. But this puts a strain on the equipment, and can involve a reduction of image quality if the exposure time increases enough to allow movement blur. The focal spot can be selected from those available in the exposure tab. Two or three point control For most procedures, there is a choice of selecting tube potential difference (kv) and tube charge (mas) [two point] or selecting tube current (ma) and time (s) separately [three point]. 15

Dental Older intra-oral machines don t set exposure time in conventional units, but set the number of impulses. Each impulse is a single mains voltage cycle. In the UK this is 0.02 seconds long, or 1/50 th of a second. In the USA it is 0.016666 seconds, 1/60 th of a second. Fluoroscopy and fluorography There are separate settings for fluoroscopic kvp and ma on most fluoroscopy equipment to allow high quality spot imaging or acquisition and low quality scout imaging that is not archived, but is used to position the instruments or fluoroscope. Older systems have continuous fluoroscopy, but modern systems can pulse the fluoroscopy for considerable radiation dose savings to both patients and operators. The rate of acquisition is often just a single exposure, but for some procedures, such as angiography, the rate can be between 6 and 50 images per second. 16

Bibliography SOR (2007) Virtual education: A reality for radiography?, The Society of Radiographers, [SYNERGY NEWS] BBC (2006) Gamers' skills aid X-ray students, BBC News, 8 July 2006, [Online] [url: http://news.bbc.co.uk/go/pr/fr/-/1/hi/england/tees/5161058.stm [Accessed 08/07/2006] SOR (2006) Students use virtual reality to train as radiographers, The society of Radiographers, [Online] [url: http://www.sor.org/public/students/news/news2.htm [Accessed 10/07/2006] 17

Index acquisition, 16 Autoscale button (AS), 7 cold (0%), 11 Exposure tab, 11 Heat Management, 5 hot (100%), 11 persist, 7 predicted spectrum, 6, 7 procedure tab, 14 scout imaging, 16 spot imaging, 16 View menu, 5 warm (70%), 11 2 point, 14 3 point, 14 2 3 A alter the collimated area, 10 Angiography, 13, 16 anode, 9, 11, 12 Anode Heel Effect, 10 B Bariums, 13 Beam Characteristics, 5, 6 Bucky examinations, 9 C cathode, 9 central ray, 9 Chest, 13 collimation, 9 comma separated variable file (.csv), 8 continuous fluoroscopy, 16 copyright free content, 8 D DAP. See Dose Area Product Default start-up screen, 4 Dental Intraoral, 13 desktop, 4 Different manufacturer s equipment, 14 Dose Area Product, 5, 9, 10 dynamic cooling, 11 E electrical energy, 11 entrance surface detector, 9 equipment, 10, 13, 14, 15, 16 Exporting the graph or spectrum data, 8 exposure button, 7, 11 exposure factors, 5, 6, 7, 14, 15 F filament size, 15 filament temperature, 12 file menu, 8 fluorography, 16 fluoroscope, 16 fluoroscopy, 10, 16 focal spot, 15 G General room, 13 generator, 11, 15 H Heat Management, 5 intra oral dental equipment, 10 intraoral, 16 kv, 15 I K L light beam diaphragm (LBD)., 10 M ma, 14, 15, 16 Mammography, 13 mas, 14, 15 Mobile, 13 modern and older x-ray rooms, 14 O overload conditions, 12 P patient thickness, 9 Photon energy, 6 Photon fluence, 6 powerpoint presentations, 8 Procedure, 4 Projection radiography, 13 R radiation field, 9 repeat exposures, 11 Resizing the Graph, 7 right hand output panel, 4 S save a graph, 8 Selecting procedures, 13 simulated x-ray spectrum, 6 Source Detector Distance (SDD), 9 Source Image Distance (SID), 9 start menu., 3, 4 Starting technicvr, 4 T tube charge, 15 tube heat capacity, 11 tube loadings, 11 Types of Detector, 9 18