RISH Clamp POWER 1000A / 400A AC-DC. Application. Product Features. Unique Design. Non Contact Voltage Detection. Three Phase Power Measurement

Similar documents
Technical Datasheet. Delta Power 1000A / 400A AC-DC

Electronic motor protection relay

RISH CON - Hz FREQUENCY TRANSDUCER

Technical Data Sheet. Delta 1000/300

MIT480/2 Series Insulation Testers

MIT2500 CAT IV Insulation Testers

PV200. Solar PV tester and I-V curve tracer

MULTIMETER FOR POWER AND ENERGY MEASUREMENT HIGH-END DIGITAL MULTIMETER

MIT2500 CAT IV Insulation testers

Analog Digital Multimeter with Insulation Resistance Measurement

PV210. Solar PV tester and I-V curve tracer

RISH MIT 30 Analog Digital Multimeter with Insulation Resistance Measurement

Jewell DPM Power / Power Factor Size 96/96 BEST IN CLASS

Trms Power Multimeter

GROUND TESTERS GROUND RESISTANCE TEST TEST EQUIPMENT DET3 CONTRACTOR SERIES WHAT S IN THE DET3T NAME? DIGITAL EARTH TESTER 3 TERMINAL

ANALOG -DIGITAL MULTIMETER NP10 USER S MANUAL

METRAClip87 and 88 Clamp Multimeters

Fluke 355 and 353 True-rms 2000 A Clamp Meters Versatile and rugged tools for applications with high currents

Fluke 345. Power Quality Clamp Meter. The ideal meter for commissioning and troubleshooting modern electrical loads

Indicator No mark Single preset Dual preset DIN W144 H72mm DIN W48 H96mm No mark DIN W72 H72mm (4 digit) (6 digit) Counter/Timer

METRAClip85 and 86 Clamp Multimeters

Current Clamp. 210

SUBJECT TO CHANGE WITHOUT NOTICE

Test & Measurement. Hand-held, ield and laboratory test and measurement instruments

GAMMA 20 DIGITAL MULTIMETER

ATK Clamp Meter

Model Display digit Size Output Power supply 24VAC 50/60Hz, 24-48VDC 9999 (4-digit) 1-stage setting

By: Pinank Shah. Date : 03/22/2006

Measurement of Equivalent Input Distortion AN 20

AME50461 SERIES EMI FILTER HYBRID-HIGH RELIABILITY

Mobrey MSP 2 wire 24V loop powered ultrasonic level transmitters

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features:

Digital Multifunction Instrument - Rish Master 3440

Min. Meas. Range flow velocity = 0 to 1.64 ft/s

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL

RISH Master Digital Multifunction Instrument with onsite pluggable output options. Application : Product Features:

HB860H 2-phase Hybrid Servo Drive

Fluke 370 FC Series true-rms wireless AC/DC clamp meters

DM-III Multitest & DM-III Multitest F Power Quality Recorders

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:

AME28461 SERIES EMI FILTER HYBRID-HIGH RELIABILITY

CareMat C DATASHEET. The pressure-sensitive mat for supervision of people with dementia and disorientation. RoHS

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

GENERATE AND MEASURE STANDING SOUND WAVES IN KUNDT S TUBE.

MINIMUM RANGE METER* CAPACITY. MAXIMUM RANGE in. mm gpm gpm L/min gpm L/min SIZE 1/

UNIVERSAL MEASURING INSTRUMENTS. TNM 34xx. TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument 1/49

KMXP SERIES Anisotropic Magneto-Resistive (AMR) Linear Position Sensors

Application Alpha 20 Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters

MINIMUM RANGE METE R* CAP ACITY MAXIMUM S IZE. in. mm gpm gpm L/min gpm L/min 1/

DM-III MULTITEST Power Quality Recorder

Versions with outputs for kwh, kvarh and kvah energy measurement, data transmission, alarms, DIN rail mounting, demand control (load shedding)

From the beginning of the 19th century, there was the yellow of amber. Then manufactured

DET4 Series. 4-Terminal Earth/Ground Resistance and Soil Resistivity Testers. DET4 Series. Earth/Ground Resistance & Soil Resistivity Testers

RS Pro ENGLISH. Datasheet

Data Sheet. RISH Master Record %THD

Digital Clamp Meter (TRMS) Model : 2727

PQA823 PQA824 Rel /01/2007

RISH Master 3430 DIGITAL MULTI-FUNCTION TRANSDUCER. Electro-Meters

1587/1577 Insulation Multimeters

ALPHA 20 MULTIFUNCTION METER (ALPHA SERIES)

ICM7213. One Second/One Minute Timebase Generator. Features. Description. Ordering Information. Pinout. August 1997

POWER CLAMP-ON METER 405

APPLICATION NOTE UNDERSTANDING EFFECTIVE BITS

ALPHA 50 MULTIFUNCTION METER (ALPHA SERIES)

Technical Explanation for Counters

Tehrani N Journal of Scientific and Engineering Research, 2018, 5(7):1-7

AMIK 200 / 201 Technical Data Sheet

High Temperature Accelerometers

For Professional Use. Safe and Robust. Performance. Ergonomics

eppe cx Requirements to be met by a measuring system for efficiently monitoring supply systems and technical equipment

Electro-Magnetic Flowmeters MINI-MAG W Vibration Limits: MAGNETIC FLOWMETER (with Integral XE Converter) Power Requirements: Power Consumption:

User s Guide. 400A AC/DC Clamp Meter. Model MA Washington Street Melrose, MA Phone Toll Free

Technical Data Sheet AMIK 300 / 301

PQA823 PQA824 Rel /03/2007

GAMMA 12 DIGITAL MULTIMETER

CLAMP-ON METER. Models 500, 501, 502, 503, 511, 512 & 514. Call toll free (800) or visit

RS Pro ENGLISH. Datasheet

Model: Pro95 TRUE RMS MILLIAMP CLAMP METER

Operating Guide October 2006

User Guide. AC/DC Mini Clamp Meter. Model

GAMMA 10 DIGITAL MULTIMETER

MID. Energy Management Energy Analyzer Type EM11 DIN. Product Description. How to order EM11 DIN AV8 1 X O1 PF. Type Selection EM11 DIN

RISH Multi 12S...18S Analog - Digital multimeters

GSC57 Rel of 257/10/05

Energy Stress of Surge Arresters Due to Temporary Overvoltages

LAV21 RMS (-T), LAV3 RMS (-T), LAA3 RMS (-T) Multi Channel Volt/Amp Recorders

Methods to Reduce Arc-Flash Hazards

USER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series

Technical Data Sheet. Zeta 20

Fluke 370 FC Series True-rms Wireless AC/DC Clamp Meters

HELIARC. THE FIRST NAME IN TIG.

Fluke 370 FC Series True-rms Wireless AC/DC Clamp Meters

PQA823 PQA824 Rel /09/18

Features. +Vout. +Vin. AHF28XX/CH (or Other) DC/DC Converter. Input Return. +Vout AHF28XX/CH (or Other) DC/DC Converter Output Return.

INCREASE OF STRAIN GAGE OUTPUT VOLTAGE SIGNALS ACCURACY USING VIRTUAL INSTRUMENT WITH HARMONIC EXCITATION

Data Sheet. RISH Max-14 Analog-Digital Multimeter. RISH Max-14 Analog-Digital Multimeter. Page 1 of 5. Rishabh Instruments 1 / 05 / IX / 1210 / B

A Full Line-up of Digital and Analog Clamp Meters to Suit Any Need

Technical Datasheet. True RMS Digital Protection Relay. Voltage Protection Relay

2000 A AC TRUE RMS DIGITAL CLAMP METER WITH NON-CONTACT EF-DETECTION

NetSure 702 DC Power System. DC Power for Business-Critical Continuity

Transcription:

RISH Clamp POWER 1000A / 400A AC-DC Applicatio RISH Clamp POWER 1000A/400A measures, calculate ad displays importat electrical parameters of sigle phase or three phase power system. It also features Resistace, cotiuity, diode ad o cotact voltage detectio. Product Features Measures followig parameters AC & DC Voltage up to 1000V AC & DC Curret up to 1000A /400 A Irush/Peak Value Measuremet Active, Reactive ad Apparet Horse Measuremet kwh Measure up to 49th Harmoics Phase Agle THD DF Factor Crest Factor LPF Mode for VFD Applicatio Uique Desig RISH Clamp POWER1000A/400A is a highly iovative desig for features those icreases safety ad comfort of user. Rotatig clamp jaws facilitate the measuremet at physically awkward positios, vertical bus bars, coductors placed at positios difficult to access. Clamp jaws ca be opeed or closed with the trigger placed at bottom side away from the jaws. This allows the user to place his/her had at safer distace from live coductor. This greatly reduces exposure of huma beigs to electrical shocks. Locatio ad desig of trigger elimiates fatigues caused by sigle figer operatio. It allows spreadig the force required to ope the jaws over more tha oe figer to esure comfortable operatio. Comfortable operatio of push buttos ad fuctio selector switch, i adverse field coditios. Large Jaw Opeig Jaw opeig of 51mm ad 41 mm for stadard wire diameter of 50mm ad 40mm for 1000A ad 400A respectively. Irush Curret Measuremet Clamp meter will be triggered by irush curret >5A. Irush curret for 100 msec is measured. DATA Hold Fuctio By pressig DATA HOLD butto, readig o the display ca be latched for Hads free operatio. MIN,MAX Fuctio By pressig MIN/MAX butto, the clamp meter will start recordig latest Miimum ad Maximum readigs Backlit It is possible to coduct measuremet usig the clamp meter durig poor light coditio with the help of bright white light Backlit. No Cotact Voltage Detectio The clamp meter ca detect the presece of AC Voltage betwee 100 to 1000 V 50hz/60Hz without ay electrical coectio ad give acoustic sigal as a idicatio. Three Phase Measuremet Clamp meter ca measure power i 3 phase 3 wire or 3 phase 4 wire (Symmetric as well as Asymmetric) etwork without ay maual calculatio like other clamp meters. Dual Display User friedly dual display shows the simultaeous parameters of measurig iput quatity. LPF Mode LPF mode is available for voltage ad curret for true measuremet of VFD Applicatio TRMS Measuremet I order to calculate true value of distorted waveform due to presece of high crest factor or harmoics, TRMS measuremets is doe for AC voltage ad curret Auto OFF I order to save the power of the Batteries, the clamp meter will automatically shut OFF if it detects o activity for 10 miutes. Cotiuous ON Mode RISH Clamp POWER 400 A AC-DC I this mode, AUTO POWER OFF is disabled. Low Battery Idicatio REL INRUSH Double molded Cover for soft touch ad firm grip of the Istrumet HOLD MIN/MAX

Referece coditios for Accuracy Referece temperature 23 C ± 2 C Relative Humidity 45%...55% RH Iput frequecy 50 or 60 Hz Factor 0.5L...1...0.5C Battery Voltage 8 V ± 0.1 V Techical Specificatio Protectio from dust ad water IP20 for termials as per IEC60529 Applicable Iteratioal Safety stadards 600 V CAT IV/1000V CAT III as per Iteratioal Safety stadard IEC 61010-1- 2010 Measurig fuctio V DC 999.9 V 0.1 V ±(0.5% of rdg + 5 dgt) V ~ 999.9 V 0.1 V ±(0.75% of rdg+5 dgt) V ACDC 999.9 V 0.1 V ±(1.25% of rdg+10dgt) LPF V~ 999.9 V 0.1 V 1000A ADC-AAC 400A ADC - AAC 1000A A ACDC 400A A ACDC LPF 1000A A AC LPF 400A A AC Active Reactive Apparet Horse kwh Measurig rage 50...60 Hz ±(0.75% of rdg + 5dgt) 61...400Hz ±(5.0% of rdg + 5dgt) 999.9A 0.1 A ±(1.5% of rdg+5 dgt) 99.99 A 0.01 A display value ±(1.5% of rdg+0.2a) <1000 add 10 400 A 0.1 A dgt ±(1.5% of rdg+5 dgt) 999.9A 0.1 A ±(3% of rdg+10 dgt) 99.99 A 0.01 A display value ±(3% of rdg+0.4a) 400 A 0.1 A <1000 add 10 dgt ±(3% of rdg+10 dgt) 999.9A 0.1 A 50...60 Hz ±(1.5% of rdg + 5dgt) 61...400Hz ±(5.0% of rdg + 5dgt) 99.99 A 0.01 A 50...60 Hz ±(1.5% of rdg + 0.3A) 61...400Hz ±(5.0% of rdg + 5dgt) 400 A 0.1 A 9.999 kw 1 W 99.99 kw 10 W 999.9 kw 100 W 9999 kw 1 kw 9.999 kvar 1 VAr 99.99 kvar 10 VAr 999.9 kvar 100 VAr 9999 kvar 1 kvar 9.999 kva 1 VA 99.99 kva 10 VA 999.9 kva 100 VA 9999 kva 1 kva 9.999 hp 0.001 hp 99.99 hp 0.01 hp 999.9 hp Resolutio 0.1 hp 9999 hp 1 hp 9.999 kwh 0.001 kwh 99.99 kwh 0.01kWh 999.9 kwh 0.1 kwh 9999 kwh 1 kwh Itrisic error of digital display at referece coditio 50...60 Hz 61...400Hz ±(1.5% of rdg + 5dgt) ±(5.0% of rdg + 5dgt) ±(2% of rdg+5 dgt) ±(3% of rdg+5 dgt) Over load capacity Over load value 1000 V DC/AC eff/rms Sie wave 1100 A AC/DC for power clamp 1000A 440 A AC/DC for power clamp 400A 1000 V DC/AC 1100 A AC/DC for Clamp 1000A 440 A AC/DC for Clamp 400A Overload duratio Cotiuously Cotiuously Cotiuously

Techical Specificatio Measurig fuctio Measurig rage Resolutio Ahr 999.9 Ahr 0.1 Ahr Phase agle 0.0 360.0 0.1 Pow er Factor -1 0 1 0.001 Harmoics (RMS & %) 1 13 0.1V 0.1A 14 49 0.1% THD 0 99.9% 0.1% DF 0 99.9% 0.1% Crest Factor 1000A Peak 400A Peak 1000A INRUSH 400A INRUSH 4) 4) 1.0 2.9 0.1 3.0 5.0 0.1 1400 A / 1400V 560 A/ 1000 V 1 A / 1 V Resistace 9999 Ohm 1 Ohm Cotiuity Below 40 Ohm 1 Ohm Diode 0 2.2V 0.001 V Itrisic error of digital display at referece coditio ±(3% of rdg+5 dgt) ±3 ±(3% of rdg+10 dgt) ±(5% of rdg+20 dgt) ±(3% of rdg+20 dgt) ±(3% of rdg+20 dgt) ±(2% of rdg+3 dgt) ±(3% of rdg+5 dgt) 1 A ±(3% of rdg+3 dgt) 100 A 0.1 A ±(3% of rdg+10 dgt) ±(3% of rdg+3 dgt) 999.9A 0.1 A ±(3% of rdg+5 dgt) 99.99 A 0.01 A ±(3% of rdg+0.3a) 400 A 0.1 A ±(3% of rdg+5 dgt) ±(0.5% of rdg+5 dgt) ±(0.5% of rdg+5 dgt) ±(0.5% of rdg+5 dgt) Over load capacity Over load value 1000 VDC/AC 1100 AAC/DC for Clamp 1000A 440 AAC/DC for Clamp 400A 1000 V DC/AC eff/rms Sie wave Overload duratio Cotiuously 10 Secs Note:- Accuracy claimed for ad Curret whe coductor is positioed at the ceter of the jaw. For DC A make auto zero correctio by log pressig the HOLD key For Clamp 1000A Accuracy Defied for V 10V ad I 5A Add 10 digit to accuracy whe power is < 5.000 kw/kvar/kva or <6.700 hp Accuracy Defied for V 10V ad I 10A 4) Accuracy Defied for I 10A For Clamp 400A Accuracy Defied for V 10V ad I 4A Add 10 digit to accuracy whe power is < 5.000 kw/kvar/kva or <6.700 hp Accuracy Defied for V 10V ad I 10A 4) Accuracy Defied for I 5A For Clamp 1000A I 1P2W mode maximum power meter ca measure is, 1000 kva / 1000 kvar / 1000 kw / 1341 hp I 3P4W mode maximum power meter ca measure is,3000 kva / 3000 kvar / 3000 kw / 4023 hp I 3P3W mode maximum power meter ca measure is,1732 kva / 1732 kvar / 1732 kw / 2322 hp For Clamp 400A I 1P2W mode maximum power meter ca measure is, 400 kva / 400 kvar / 400 kw / 536 hp I 3P4W mode maximum power meter ca measure is,1200 kva / 1200 kvar / 1200 kw / 1608 hp I 3P3W mode maximum power meter ca measure is,693 kva / 693 kvar / 693 kw / 928 hp AC curret measuremet i both 1000A ad 400A model starts from 0.5A i AC Amp mode ad from 1A i LPF mode

Ifluece Quatity Ifulece quatity Temperature Frequecy of the measured quatity Crest Factor Supply Voltage Relative humidity Rage of Ifuece 0 ºC 21 ºC ad 25 ºC.50 ºC 40 Hz 50 Hz ad 60 Hz.400 Hz Measured quatity / Measurig Rage V AC V DC V ACDC A AC A DC A ACDC AC DC Resistace/ Diode/ Cotiuity V AC V ACDC A AC A ACDC Variatio 0.15 X Itrisic Error / ºC 1 X Itrisic Error 45 Hz.65 Hz AC 1.4 2 1% + Itrisic Error V AC 2 2.5 2.5% + Itrisic Error A AC 2.5...5 4% + Itrisic Error Whe Low Battery All Rages 1 X Itrisic Error symbol is ON 75% All Rages 1 X Itrisic Error Except SieWave CF 2 @ 690V, 690Afor Clamp Meter 1000 A ACDC CF 3 @ 690V, 186A for Clamp Meter 400 A ACDC CF 4 @ 345V, 345A for Clamp Meter 1000 A ACDC CF 4 @ 345V, 140A for Clamp Meter 400 A ACDC CF 2 @ 690V, 280A for Clamp Meter 400 A ACDC CF 5 @ 280V, 280A for Clamp Meter 1000 A ACDC CF 3 @ 460V, 460A for ClampMeter 1000 A ACDC CF 5 @ 280V, 112A for Clamp Meter 400 A ACDC Except for 50 or 60 Hz

Evirometal Operatig temperature 0 to +55 C Storage temperature -20 to +70 C Temp. Coefficiet 0.15 X(Itisic Error) / C Relative humidity 0... 75% o codesig Termial Protectio IP50 for Housig ad IP20 for termials Applicable Stadards EMC Electro magetic compatibility Emissio IEC 61326: 2012 ClassB Immuity IEC 61326: 2012 IEC61000-4-2 :- 8 KV air discharge, 4 KV cotact discharge IEC 61000-4-3 :- 3 V/m Safety IEC 61010-1-2010 IP for water & dust IP 50 for housig IP 20 for termial Pollutio degree 2 Istallatio category III IV 1000V 600V High Voltage Test betwee housig ad iput. 7.4 kv AC, 50Hz for 1 miute betwee housig with jaws ad 4.26 kv AC, 50Hz for 1 miute iput. Display Display Seve Segmet Character Height Mai Display Character : 11.5 mm Sub Display Character : 7.2 mm Number of digits 4 digits. Maximum cout 9999 couts For V, I ad 9999 couts For Resistace Over rage idicatio OL is displayed Polarity idicatio sig is displayed for egative values. Battery Battery Voltage Battery type Cosuptio Battery Life Scope of delivery Clamp Meter Probe Set Istructio Maual/Warraty card Clamp Carryig Case Test Certificate Battery Two crocodile clips Mechaical Cofiguratio Dimesios 90mm(W)x270mm(L)x70mm(H) Weight 500gm approx. icludig battery. 9 V DC Magaese Dioxide Cell as per IEC6F22 Alkalie magaese cell as per IEC 6LR 61 20 ma Avg. (Without Backlight) 48 Hrs Approx.