Technical Specifications Micromedical VisualEyes 505 by Interacoustics

Similar documents
VN415/VO425 Specifications

BIODEX MULTI- JOINT SYSTEM

Guidance and Declaration - Electromagnetic Compatibility (EMC) for the Delfi PTS ii Portable Tourniquet System

HeRO duet

Powered Traction Unit OPERATION MANUAL

Electromagnetic compatibility Guidance and manufacturer s declaration DIN EN :2007 (IEC :2007)

English

OtoRead - Technical Specifications Page 0. Technical Specifications. OtoRead D A 2017/06

Biological Safety. Electromagnetic Compatibility (EMC) Observe the following precautions related to biological safety.

General Safety/EMC and Electrical Information for i-limb ultra and i-limb digits

D C 01/2019 3

Nursing Beds with Dewert drive system

(c) Medisave UK. Notice. Edition 1. i-pad Operator s Manual

Technical Data. Electrocardiograph ECG-1250K TD.ECG1250_L. This technical data may be revised or replaced by Nihon Kohden at any time without notice.

MedRx Avant Polar HIT AH-I-MPHITS-5 Effective 11/07/11

User Instruction Computer Assisted Local Analgesia. 337 Marion, Le Gardeur QC, Canada, J5Z 4W8

PHYSIOFLOW Q-LINK TM

USER MANUAL MHS-2500I. Please take time to read these instructions before starting to use the scale. Version /17

TH008F Multi-function Infrared Forehead Thermometer

Rolyan Splint Pan OPERATION MANUAL. Item # Small Item # Large

DENTAL X-RAY OPERATOR'S INSTRUCTIONS. (for USA) Wall Mount Type...WK

#

INSTALLATION MANUAL AVANT HIT+ Hearing Instrument Test Chamber.

Operating Manual Infrared thermometer

USER MANUAL M-200. Please take time to read these instructions before starting to use the scale. Version /06

`bob`=p=^åèìáëáíáçå=råáí=bma

INTRODUCTION. 4 SAFETY INSTRUCTIONS. 5 ABOUT THIS DEVICE. 6 FIRST OPERATION. 7 THE DISPLAY. 8 ATTACHING THE WRIST SLEEVE. 9 CORRECT MEASUREMENT.

Ceiling Model Ceiling Model for LEDview Plus and Heliodent Plus. Installation Requirements. New as of: English

`bob`=p=^åèìáëáíáçå=råáí

Not for print. Microphone Test Device with SONNET MTD Adapter. User Manual. Cochlear Implants NOT FOR PRINT

M-400 M-410 M-420 M-430

The following languages can be found on our website: French. German. Spanish. Italian. Swedish. Portuguese. Russian. Dutch.

SAVI SCOUT Surgical Guidance System. Console Operation Manual

: 0089 GTIN

WRIST BLOOD PRESSURE MONITOR

Rotating Anode X-Ray Tube Housing Assembly. General Data

The following symbol indicates that the device is MR-unsafe:

#0086.

USER S MANUAL Volk Pictor Plus Fluorescein Angiography (FA) Module For Use with: Volk Pictor Plus

EMC TEST REPORT For MPP SOLAR INC Inverter/ Charger Model Number : PIP 4048HS

EMC Test Report. Report Number: M030826

2620 Modular Measurement and Control System

OPERATOR'S INSTRUCTIONS DX-073 DENTAL X-RAY

GTIN:

OPERATOR S INSTRUCTIONS (for USA & Canada)

TEST REPORT... 1 CONTENT...

Multi-Control Panel for built-in system. Multi Pad for NLX / imd OPERATION MANUAL OM-E0538E 001

OPERATOR S MANUAL AN APPLIED DIGITAL COMPANY

H2 Check Operating Manual

How to use the Barcode Scanner:

SPAC265-8W. AC-DC power supply module. Features. Description. Applications

INSTRUCTIONS FOR YOUR NEW PLASMAFLOW. Vascular Therapy System (Compressible Limb Sleeve Device)

The Symbol means that the Vet-Tech (200, 250 or 300HF) system intentionally applies some radioelectric energy for diagnostic or treatment purposes.

Central Blood Pressure Meter Model cbp301. Operating Manual

IEC Second Edition

OPERATOR'S INSTRUCTIONS DENTAL X-RAY MODEL 096

Laboratory Accreditation Programmes

SJM MRI Activator. Handheld Device. User's Manual. Model EX4000

Exergen TAT 5000S RS232 TTL Supplemental Instructions for Use

MINISCAV Vacuum Pump Manual

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 25. Page 2 of 25

Overview of EMC Regulations and Testing. Prof. Tzong-Lin Wu Department of Electrical Engineering National Taiwan University

EN61326 EMC COMPLIANCE REPORT on the LP Series Ultrasonic Transmitter Remote Amplifier and Transducer for Hawk Measurement Systems Pty Ltd

L NKTEMP. Non-contact. Infrared Thermometer. User Manual LMP001

satech SynchroStar GPS 200 Series

This annex is valid from: to Replaces annex dated: Locations where activities are performed under accreditation

EMC Test report for LED Panel Light Models , , , , ,

Operator s Manual External Remote Controller (ERC)

DIGITAL BLUETOOTH THEROMETER PBT

Discontinuous Disturbance (Click) EN :2006+A1:2009+A2:2011 Clause N/A** Radiated Emission, 30MHz to 1000MHz

EMC REPORT. ShenZhen KY Technology Co.,Ltd. No.369, BaoTian 1st RD, TieGang Industrial Park, Xixiang Town, Baoan District, ShenZhen, PRC.

CardioMessenger II-S Transmitter for BIOTRONIK Home Monitoring. Technical Manual

EMC TEST REPORT. Report No.: TS EME Model No.: 33XR-A Issued Date: Jan. 08, 2009

Welch Allyn Home Scale (T- RPM-SCALE100)

POCKET AIR. Portable Nebulizer. Instruction Manual MBPN002 / MB / MB05006

OPSJ1900 J1900 Open Pluggable Specification Products

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 27. Page 2 of 27

EMC standards. Presented by: Karim Loukil & Kaïs Siala

One-day Conference 18 March Power Supply, EMC and Signalling, in Railway Systems

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation

Product Name: COMPER SMART DOPPLER FETAL MONITOR. Product Model: DFMX

National Voluntary Laboratory Accreditation Program

By order of American Power Conversion Holdings Inc. at New Taipei City, Taiwan

EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass

ENG en. Operating instructions. Iris Magneton MF Wellness therapy

By order of ZHONGSHAN LIANGYI LIGHTING CO., LTD. at Zhongshan, China

User Manual. Before Using Your WiTouch Pro Device

Harmonic Current emission EN :2014 Class A Pass. Voltage Fluctuation and Flicker EN :2013 Clause 5 Pass

AUTOMATIC BLOOD PRESSURE MONITOR (Arm Cuff Type) INSTRUCTION MANUAL

EMC test report AU01+E04

Relief. At Last. User Manual For an effective treatment, read the entire User Manual before using Kyrobak.

By Paul Aylett at 12:08 pm, Apr 13, 2016

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

National Voluntary Laboratory Accreditation Program

EMC Seminar Series All about EMC Testing and Measurement Seminar 1

User Manual. Use, Maintenance and Service of the. Sinuscan 301

EN 55022: 2010+AC:2011 Clause 6.1 Pass. Harmonic Current EN :2006+A1:2009+A2:2009 Class A N/A

Report for Excelsys EMC Measurements for 4Xgen Purchase Order: Project Number EMT07J026 Rev. B

Product Manual N.2 WEARABLE ECG. PRODUCT MANUAL

EMC TEST REPORT. NORTE SIRIUS ENTERPRISE CO., LTD , Shin-Sheng St., Chung-Ho Dist, New Taipei City, Taiwan

Transcription:

VisualEyes 505 - Technical Specifications Page 0 Technical Specifications Micromedical VisualEyes 505 by Interacoustics D-0115523-B 2018/02

VisualEyes 505 - Technical Specifications Page 1 Included and Optional Parts As standard, VisualEyes 505 system is delivered with the following: Included parts Optional parts based on goggle type USB camera systems Remote Control or Foot pedal Instructions for Use VisualEyes 505 installation media OtoAccess Database media VisualEyes 505 Quick Start Guide 2D-VOGfw goggle w. side mounted cameras USB 2.0 camera module (two modules in binocular configuration) Disposable goggle foam pads Box of 24 pcs 1.5 mm hexagon screwdriver for camera retaining screws 7-port USB 3.0 hub w. external power supply USBM2.1A goggle w. front mounted camera Adult mask for USB monocular camera Camera module with 15 USB cable 7-port USB 3.0 hub w. external power supply USBM2.1P goggle w. front mounted camera Pediatric mask for USB monocular camera Camera module with 15 USB cable A to Mini B 7-port USB 3.0 hub w. external power supply BG4.0KUSB goggle w. top mounted cameras Goggles USB Asian faceplate binocular Two 15 USB cables A to Mini B 7-port USB 3.0 hub w. external power supply BG4.0USB goggle w. top mounted cameras Goggles USB Binocular Two 15 USB cables A to Mini B 7-port USB 3.0 hub w. external power supply FireWire camera systems 2D-VOGfw goggle w. side mounted cameras FireWire camera module (two modules in binocular configuration) Disposable goggle foam pads Box of 24 pcs PCExpressCard stabilization kit (laptop configuration) PCExpressCard (for laptop configuration) PCI ExpressCard (for tower PC configuration) 4-port USB hub

VisualEyes 505 - Technical Specifications Page 2 General Technical Specifications PC Hardware and Software Laptop: 34mm PCExpressCard Slot (for side mount FireWire goggles only). Desktop: 1 free PCI Express slot (for side mount FireWire goggles only). Intel i5 processor 2.5 GHz or better. Minimum 8 GB RAM or more. Hard drive with min. 250GB space. Minimum display of 1366X768 (Higher resolution recommended). Operating systems supported: Windows 7 32-bit and 64-bit. Windows 8.1 64-bit. Windows 10 64-bit. Power supply: Use only UE15WCP1 for side mount FireWire VNG goggle with Laptop computer Operation and storage specifications Operation environment: Temperature: 15 35 C Relative Humidity: 30 90% Transport & Storage: Storage Temperature: 0 50 C Transport Temperature: -20 50 C Rel. Humidity: 10 95% Systems can operate on 100 to 240 VAC at frequencies of 50/60Hz. Only power cables supplied should be used with the equipment. Standards IEC 60601-1: 2012 IEC 60601-1-2: 2014 IEC 60825-1 or IEC 62471 ANSI S3.45. Medical electrical equipment Part 1: General requirements for basic safety and essential performance Medical electrical equipment Part 1-2: General requirements for basic safety and essential performance Collateral standard: Electromagnetic compatibility Requirements and tests Safety of laser products Photobiological safety of lamps and lamp systems Performance standard Component Specifications Top mount VNG goggle Binocular video eye tracking goggles. Removable eye cover for vision enabled or vision denied recording. USB 2.0, 4.5m dual cables to PC. Resolution: 320 x 240 Pixels @ 100 Hz. Images: 100 images per second. Dimensions (L x W x H) 165 x 165 x 89mm. Horizontal and Vertical Eye movement measurement resolution: approx. 0.33 degrees. Single IR LED infrared illumination: 950 nm at 1.5 mw/cm2.

VisualEyes 505 - Technical Specifications Page 3 Goggle Weight: Binocular VNG cameras 345g (occluded view) without cables. Component Specifications Front mount VNG goggle Monnocular video eye tracking goggles. Swivel eye portal cover for vision enabled or vision denied recording. USB 2.0, 4.5m cable to PC. Resolution: 640 x 480 Pixels @ 30 Hz. Images: 30 images per second. Dimensions (L x W x H) 165 x 165 x 89mm. Horizontal and Vertical Eye movement measurement resolution: approx. 0.25 degrees. Dual IR LED infrared illumination: 950 nm at 1 mw/cm2. Goggle Weight: Binocular VNG cameras 254g without cable. Component Specifications Side mount VNG goggle Monocular/ Binocular video eye tracking goggles. Removable eye cover for vision enabled or vision denied recording. USB2.0 IEEE1394 FireWire. Resolution: 640 x 240 Pixels @ 100 Hz. Images: 100 images per second. Dimensions (L x W x H):302 x 216 x 131mm. Goggle Weight: Monocular VNG Camera 240g (non-occluded view). 320g (occluded view). Binocular VNG cameras 305g (non-occluded view). 385g (occluded view). Dispensing box with 24 pcs of disposable goggle foam pads. Isolation transformer: Standard: IEC60601-1 Power: Please ensure the isolation transformer is rated for at least the total power of the supplied equipment e.g. LCD screen, video projector, computer, LCD monitor, printer etc.

VisualEyes 505 - Technical Specifications Page 4 Electromagnetic compatibility (EMC) for top-mounted goggles The VNG was tested to IEC60601-1-2 standards regarding EMC. This allows you to install and use the VNG in classic environments, but it does not allow you to use it in harsh environments like operating rooms where there are many devices producing electromagnetic fields. Medical electrical equipment needs special precautions regarding electromagnetic compatibility (EMC) and needs to be installed and put into service according to the EMC information provided. Caution Portable RF communications equipment (including peripherals such as antenna cables and external antennas) should be used no closed than 30 cm (12 inches) to any part of the VNG including cables specified by the manufacturer. Otherwise, degradation of the performance of this equipment could result. The VNG was tested for EMC compliance as a Group 1, Class B device. Caution Use of accessories, transducers, and cables other than those specified or provided by the manufacturer of this equipment could result in increased electromagnetic emissions or decreased electromagnetic immunity of this equipment and result in improper operation. Contact Micromedical for approved replacement parts. Important The emissions characteristics of this equipment make it suitable for use in industrial areas and hospitals (CISPR 11 class A). If it is used in a residential environment (for which CISPR 11 class B is normally required) this equipment might not offer adequate protection to radio-frequency communication services. The user might need to take mitigation measures, such as relocating or reorienting the equipment. Guidance and Manufacturer s declaration Electromagnetic Emissions The VNG is intended for use in the electromagnetic environment specified below. The customer or the user of the VNG should assure that it is used in such an environment. Emissions Test Compliance Electromagnetic environment - guidance The VNG uses RF energy only for its internal functions. Therefore, its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment. RF emissions CISPR 11 Group 1 RF emissions CISPR 11 Class B The VNG is suitable for use in all Harmonic emissions IEC 61000-3-2 Class B Voltage fluctuations/ flicker emissions complies IEC 61000-3-3 establishments, including domestic establishments and those directly connected to the public low voltage power supply network that supplies buildings used for domestic purposes.

VisualEyes 505 - Technical Specifications Page 5 Guidance and Manufacturer s declaration Electromagnetic Immunity The VNG is intended for use in the electromagnetic environment specified below. The customer or the user of the VNG should assure that it is used in such an environment. Immunity Test IEC 60601 test level Compliance Level Electromagnetic environment Electrostatic discharge immunity (ESD) IEC 61000-4-2 Radiated RF Immunity IEC 61000-4-3 Electrical fast transient/burst IEC 61000-4-4 Surge immunity IEC 61000-4-5 Conducted RF Immunity IEC 61000-4-6 Power Frequency Magnetic Immunity IEC 61000-4-8 Voltage dips, short interruptions and voltage variations on power supply input IEC 61000-4-11 +/- 6 kv contact +/- 8 kv air +/- 6 kv contact +/- 8 kv air guidance Floors should be wood, concrete or ceramic tile. If floors are covered with synthetic material, the relative humidity should be at least 30%. Stress 4.5 V/M Stress 4.5 V/M Not Applicable +/- 2 kv for power supply +/- 1 kv for input/output +/- 1 kv line(s) to line(s) +/- 2 kv line(s) to earth +/- 2 kv for power supply. No input/output +/- 1 kv line(s) to line(s) +/- 2 kv line(s) to earth Mains power quality should be that of a typical commercial or hospital environment. Mains power quality should be that of a typical commercial or hospital environment. Stress 3V and 10V Stress 3V and 10V Not applicable 30 A/m 30 A/m Power frequency magnetic fields should be at levels characteristic of a typical location in a typical commercial or hospital environment. 0% UT 10ms 40% UT 100ms 70% UT 500ms 0% UT 5000ms 0% UT 10ms 40% UT 100ms 70% UT 500ms 0% UT 5000ms NOTE: UT is the mains voltage prior to application of the test level. Mains power quality should be that of a typical commercial or hospital environment. If the user of the VNG requires continued operation during power mains interruptions, it is recommended that the VNG be powered from an uninterruptible power supply or battery.

VisualEyes 505 - Technical Specifications Page 6 Electromagnetic compatibility (EMC) for side mounted goggles Portable and mobile RF communications equipment can affect the VisualEyes system. Install and operate VisualEyes according to the EMC information presented in this chapter. VisualEyes has been tested for EMC emissions and immunity as a standalone VisualEyes. Do not use VisualEyes adjacent to or stacked with other electronic equipment. If adjacent or stacked use is necessary, the user should verify normal operation in the configuration. The use of accessories, transducers and cables other than those specified, with the exception of servicing parts sold by Interacoustics as replacement parts for internal components, may result in increased EMISSIONS or decreased IMMUNITY of the device. Anyone connecting additional equipment is responsible for making sure the system complies with the IEC 60601-1-2 standard. Guidance and manufacturer s declaration - electromagnetic emissions VisualEyes is intended for use in the electromagnetic environment specified below. The customer or the user of VisualEyes should assure that it is used in such an environment. Emissions Test Compliance Electromagnetic environment - guidance RF emissions CISPR 11 RF emissions CISPR 11 Harmonic emissions IEC 61000-3-2 Voltage fluctuations / flicker emissions IEC 61000-3-3 Group 1 Class B Not Applicable Not applicable VisualEyes uses RF energy only for its internal function. Therefore, its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment. VisualEyes is suitable for use in all commercial, industrial, business, and residential environments. Recommended separation distances between portable and mobile RF communications equipment and VisualEyes. VisualEyes is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of VisualEyes can help prevent electromagnetic interferences by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and VisualEyes as recommended below, according to the maximum output power of the communications equipment. Rated Maximum output power of transmitter [W] Separation distance according to frequency of transmitter [m] 150 khz to 80 MHz d = 1.17 PP 80 MHz to 800 MHz d = 1.17 PP 800 MHz to 2.5 GHz d = 2.23 PP 0.01 0.12 0.12 0.23 0.1 0.37 0.37 0.74 1 1.17 1.17 2.33 10 3.70 3.70 7.37 100 11.70 11.70 23.30 For transmitters rated at a maximum output power not listed above, the recommended separation distance d in meters (m) can be estimated using the equation applicable to the frequency of the transmitter, where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer. Note 1 At 80 MHz and 800 MHZ, the higher frequency range applies. Note 2 These guide may not apply to all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people.

VisualEyes 505 - Technical Specifications Page 7 Guidance and Manufacturer s Declaration - Electromagnetic Immunity VisualEyes is intended for use in the electromagnetic environment specified below. The customer or the user of VisualEyes should assure that it is used in such an environment. Immunity Test IEC 60601 Test Compliance Electromagnetic Electrostatic Discharge (ESD) IEC 61000-4-2 Electrical fast transient/burst IEC61000-4-4 Surge IEC 61000-4-5 Voltage dips, short interruptions and voltage variations on power supply IEC 61000-4-11 Power frequency (50/60 Hz) IEC 61000-4-8 level +6 kv contact +8 kv air +2 kv for power supply +1 kv for input/output +1 kv differential mode +2 kv common mode < 5% UT (>95% dip in UT) for 0.5 cycle 40% UT (60% dip in UT) for 5 cycles 70% UT (30% dip in UT) for 25 cycles +6 kv contact +8 kv air Not applicable +1 kv for input/output Not applicable Not applicable Environment-Guidance Floors should be wood, concrete or ceramic tile. If floors are covered with synthetic material, the relative humidity should be greater than 30%. Mains power quality should be that of a typical commercial or residential environment. Mains power quality should be that of a typical commercial or residential environment. Mains power quality should be that of a typical commercial or residential environment. If the user of VisualEyes requires continued operation during power mains interruptions, it is recommended that VisualEyes be powered from an uninterruptable power supply or its battery. <5% UT (>95% dip in UT) for 5 sec 3 A/m 3 A/m Power frequency magnetic fields should be at levels characteristic of a typical location in a typical commercial or residential environment. Note: UT is the A.C. mains voltage prior to application of the test level. Guidance and manufacturer s declaration electromagnetic immunity VisualEyes is intended for use in the electromagnetic environment specified below. The customer or the user of VisualEyes should assure that it is used in such an environment, Immunity test IEC / EN 60601 test level Compliance level Electromagnetic environment guidance Portable and mobile RF communications equipment should be used no closer to any parts of VisualEyes, including cables, than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter. Conducted RF IEC / EN 61000-4-6 3 Vrms 150kHz to 80 MHz 3 Vrms Recommended separation distance d = 1, 2 P

VisualEyes 505 - Technical Specifications Page 8 Radiated RF IEC / EN 61000-4-3 3 V/m 80 MHz to 2,5 GHz 3 V/m d = 1, 2 d = 2, 3 GHz P P 80 MHz to 800 MHz 800 MHz to 2,5 Where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer and d is the recommended separation distance in meters (m). Field strengths from fixed RF transmitters, as determined by an electromagnetic site survey, (a) should be less than the compliance level in each frequency range (b) Interference may occur in the vicinity of equipment marked with the following symbol: NOTE1 At 80 MHz and 800 MHz, the higher frequency range applies. NOTE 2 These guide may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people. (a) Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which VisualEyes is used exceeds the applicable RF compliance level above, VisualEyes should be observed to verify normal operation, If abnormal performance is observed, additional measures may be necessary, such as reorienting or relocating VisualEyes. (b) Over the frequency range 150 khz to 80 MHz, field strengths should be less than 3 V/m.

VisualEyes 505 - Technical Specifications Page 9 To ensure compliance with the EMC requirements as specified in IEC 60601-1-2, it is essential to use only the following accessories: EUT Support Equipment ITEM MANUFACTURER MODEL DC Power Supply UE UE15WCP1 Firewire PCIExpress Card n/a n/a EUT Support Cables Description Length Screened Connector DC Power Supply 2m Yes FireWire 1394a Firewire PCIExpress Card 2 No DC Power This VisualEyes is suitable in hospital environment except for near active HF surgical equipment and RF shielded rooms of systems for magnetic resonance imaging, where the intensity of electromagnetic disturbance is high. Use of accessories, transducers and cables other than those specified or provided by the manufacturer of this equipment could result in increased electromagnetic emissions or decreased electromagnetic immunity of this equipment and result in improper operation. The list of accessories, transducers and cables can be found in the EMC appendix of this instruction Portable RF communications equipment (including peripherals such as antenna cables and external antennas) should be used no closer than 30 cm (12 inches) to any part of this VisualEyes, including cables specified by the manufacturer. Otherwise, degradation of the performance of this equipment could result.