TECHNICAL DATA SHEET FOR Uni-tube Single Mode Optical Fibre Cable ARMORED. (SM 2~24 Fibers)

Similar documents
TECHNICAL DATA SHEET FOR Single Mode Optical Fibre Cable Duct Application

TECHNICAL DATA SHEET FOR Single Mode Optical Fibre Cable Direct Burial Application

ekсkoм TECHNICAL DATA SHEET FOR Duct/Aerial Application kabeli.eu (SM 24 Fibers) Technical literature for Optical Fiber Cable

Optical Fiber Jelly. PBT loose tube. PE shealth. Aramid Yarn SINGLE MODE OPTICAL FIBER ITU-T REC. G.652D

TECHNICAL DATASHEET FOR LOOSE TUBE OPTICAL FIBER CABLE. Air Blown Micro LC Cable

SPECIFICATION. Optical Fiber Cable

ADSS Fiber Optic Cable. DESCRIPTION core, Single-mode/Multi-mode. Version: V2.0

Outdoor, CCTV or CCTV, Fig 8 Armored.

Outdoor, Fig 8 Armored, Multi Tube

HES HACILAR ELEKTRİK SANAYİ VE TİC.A.Ş.

Optical Fiber Cable. MODEL:GYTA53 PE Jacket. optic.com. For detailed inquiry please contact our sales team at:

Data sheet OpDAT connection cable 2x1 OS2 - bend insensitive

GYFY-24FO Total Dry. Item Material Description PE outer sheath HDPE Nominal thickness:1.8mm

ETK Kablo SPECIFICATION. FOR SINGLE-MODE OPTICAL FIBER (FutureGuide -LWP)

Standard Monotube SAFE

Dax DX-S10121 (12F Sin ngle Mode Armoured Fiber Cable -Uni-Tube Design) Introduction:

SPECIFICATION. FOR SINGLE-MODE OPTICAL FIBER (FutureGuide -SR15E)

LSSS-OF FOR. Zero Water Peak Single-Mode Optical Fiber. (Reference: ITU-T G.652.D) Prepared by Eun Kyung Min Engineer Passive Solution Team

GAAG. Multi Loose Tube Cables Outdoor - ADSS A-DQ(ZN)2Y(T) v4.0. Ordering Information. Applications. Features & Benefits

GORN. Central Loose Tube Cables Outdoor A-DQ(ZN)B2Y Improved Rodent Protection, 1000N Permanent Load v6.0. Ordering Information

GUXW. Mini-Breakout Cables (Distribution) Universal Indoor/ Outdoor, Steel Wire Armor (SWA) A/I-VQ(ZN)HBH Full Rodent Protection v5.

Ø560*336mm 4.25 kg 2100 ± 105m

Ø 1250 * 688 mm 93 kg ± 105m

ZHONGTIAN TECHNOLOGIES CO., LTD ZHONGTIAN TECHNOLOGIES FIBER OPTICS CO., LTD

JFOC-BSG2D MODEL:JFOC-BSG2D. optic.com. For detailed inquiry please contact our sales team at:

SPECIFICATION FOR SINGLE-MODE OPTICAL FIBRES

Data sheet OpDAT breakout cable 24x1 OM4 - bend insensitive

K20 & L120 LSZH Armoured F/FTP Cat6 Cables

Cores layed up around conductive filler with aramid rope in the center Rubber, special compound, mechanical properties acc.

Type QG-G50-2C- M-BU

ENDLESS INNOVATION OPTICAL FIBER. Bendfree Bendfree+ UltraPass. WidePass. Ultra Bendfree

Optical Systems Contents

OpDAT Universalkabel 1x4 OM4 - biegeunempfindlich, Klasse. Principle diagram

Electric cables. Cranes

Optical Ground Wires (OPGW)

INTERNATIONAL TELECOMMUNICATION UNION TRANSMISSION MEDIA CHARACTERISTICS CHARACTERISTICS OF A DISPERSION-SHIFTED SINGLE-MODE OPTICAL FIBRE CABLE

OFS AllWave non-dispersion shifted single-mode optical fiber

TwenCombi Cat-5E FTP(3x) - Coax 9 - EIBA - tube PE 5 mm

1.1_KV PVC insulated PVC sheathed multicore Aluminium Cable (armoured & unarmoured)

Nufern 980 nm Select Cut-Off Single-Mode Fiber

IEEE July 2001 Plenary Meeting Portland, OR Robert S. Carlisle Sr. Market Development Engineer

ENERGY CORDAFLEX (SMK) (N)SHTOEU Low Voltage Reeling Cable

Fiber Optic Outside Plant Cables (4-144 Fibers)

TECHNICAL SPECIFICATION FOR 11KV, 3C x95mm mm 2 AERIAL BUNCHED CABLES FOR OVERHEAD LINES (CROSSED LINKED POLYTHENE DRY GAS CURED)

Article number: Sheath marking ACE - TKF LTC ADSS 24x SM G.657.A1 (2x12) A-DQ(ZN)2Y {Batch} {Year} {Length}

OptoLup TM POF cable Data Sheet. Overview. COMOSS OptoLup TM Cable is a type of APF, All. for the transmitting. compliant POF cables.

kv: medium voltage reeling cable with fibreoptics

Datasheet Outside Plant Cable

MGVCL/MM/ /2082/11KV AB CABLE TECHNICAL SPECIFICATION FOR 11KV AERIAL BUNCHED CABLES FOR OVERHEAD LINES

11-SDMS-03 REV. 02 SPECIFICATIONS FOR

WIRE & CABLE. 99 Wire Low fire hazard wire and cable

SPECIFICATION SS-140/9. 0.6/1 (1.2) kv CONTROL AND POWER UNDERGROUND CABLES WITH PVC OR XLPE INSULATION AND PVC JACKET

ABOUT US ABOUT US 1 CRANE CABLES

Industrial Automation

ZHONGTIAN TECHNOLOGIES CO., LTD

Wire and Cable. 99 Wire Dual Wall 120ºC rated, Modified Polyester Low fire hazard wire and cable. Features & Benefits

PERFORMANCE SPECIFICATION SHEET

ZHONGTIAN TECHNOLOGIES CO., LTD

Cable Type 100. CAI Certification Specification

Ship Hybrid Cable DL 58 5 x UC1500 SS22 2x SM BendBright XS G.657.A2 6x MM MaxCap-BB-OM4

features and benefits

Cable Type 125. CAI Certification Specification

ITU-T G.654. Characteristics of a cut-off shifted single-mode optical fibre and cable

VSOF-BS403A. Splice Closure for Fiber Optic Cable User Manual Rev.3

COPPER + LWL RAW CABLES

DESIGNING AND DEPLOYING SPECIAL MULTI FUNCTION FIBER OPTIC CABLES

ALTOS Lite Gel-Free, Single-Jacket, Single-Armored Cables, Fibers

SUBMERSIBLE PUMP CABLES

For Public Comment DRAFT MALAYSIAN STANDARD STAGE : PUBLIC COMMENT (40.20) DATE : 01/10/ /11/2015

EC 200 CHARACTERISTICS D A T A S H E E T. Kabelwerk EUPEN AG cable. M e c h a n i c a l c h a r a c t e r i s t i c s

u n a B Optical Cables UNIFLEX CABLES LTD.

RHEYCORD (RTS) (N)SHTOEU-J in line with DIN VDE 0250 part 814

RHEYCORD (RTS) (N)SHTOEU-J in line with DIN VDE 0250 part 814

ITU-T G.656. Characteristics of a fibre and cable with non-zero dispersion for wideband optical transport

Single-Armored Cables, Fibers

CommunicationCables FIBER OPTICS OPGW FTTH

Industrial Ethernet OPT cable manufactured for Petrol Forecourt Applications.

MESP TECHNICAL SPECIFICATION FOR CATENARY WIRE HARD-DRAWN COPPER 37/ mm 2

Integrating Global Communications...

DRAFT MALAYSIAN STANDARD. Telecommunication cable: Single-mode optical fibre cable - Loose tube type for aerial installation

TONGFENG FLEXIBLE CONDUIT TONGFENG FLEXIBLE CONDUIT

Data sheet MC GC1000 pro23 Cat.7 S/FTP 4P LSHF-FR 1640 ft

Information technology. Generic cabling systems, General requirements

MESP TECHNICAL SPECIFICATION FOR TRANSMISSION WIRE HARD-DRAWN COPPER 19/ mm 2

HO7RN-F 450/750V BS EN Highly Flexible Rubber Cable

This special provision is for the installation and testing of the following equipment:

TECHNICAL ARTICLE: DESIGN BRIEF FOR INDUSTRIAL FIBRE OPTICAL NETWORKS

CAT 5e UTP Cable: NETSET BOX [305m], indoor

Welding Cables Rubber Insulated

MV water-proof and water tree retardant power cable

REPORT OF PERFORMANCE TIC

FSM-30P SPECIFICATIONS FOR FIBER FUSION SPLICER 1. GENERAL

Data sheet MC GC1200 pro22 Cat.7A S/FTP 4P LSHF-FR, class Dca s2 d2

Advanced Fibre Testing: Paving the Way for High-Speed Networks. Trevor Nord Application Specialist JDSU (UK) Ltd

HERMETICALLY SEALABLE PATCHCORDS WITH METAL SOLDER

CABLES FOR MOTION CONTINUOUS-BENDING HI-FLEX ELECTRICAL CABLES TOTALTRAX TURN-KEY SYSTEMS PRE-ASSEMBLED CABLES STRAIN RELIEF DEVICES

JULY Standards are finally approved by the Standards High Council of Iranian Ministry of Petroleum.

COMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD

There are lots of problems or challenges with fiber, Attenuation, Reflections, Dispersion and so on. So here we will look at these problems.

2. CONDUCTORS. 2.1 Strand Types. 2.2 Coatings Tensile Strength of Copper Wire Copper Strand Properties. 2.5 Aluminum Strand Properties

Transcription:

TECHNICAL DATA SHEET FOR Uni-tube Single Mode Optical Fibre Cable ARMORED (SM 2~24 Fibers) Product: Single Mode Optical Fiber Cable Producer: XCOM LTD. / Bulgaira Date: August 1, 2012 Write by: Petar Georgiev / technical engineer XCOM LTD. BUGARIA Екском ЕООД, гр. Пловдив, ул. Братя Бъкстон 134 Tel: +359 899 993 063; +359 32 399 565 http://www.xcombg.com xcomeood@gmail.com Page 1 of 6

1 Cable Construction 1.1 Cable cross-section 2. Cable Specification 2.1 Sheath marking XCOM 2012 UT01 XXB1.3 (G.652D) XXXXm XCOM : Manufacturer s brand 2012 : Manufacture year UT01 : Cable type XXB1.3 (G.652D) : XX cores single-mode optical fiber (ITU-T Rec. G.652 D ) XXXXm : Mark of meters *The marking is printed every 1 meter; ** G.652D means ITU-T Rec. Low Water Peak (LWP) G.652 Single Mode Optical Fiber. 2.2 The color of marking is white, but if the remarking is necessary, the yellow color marking shall be printed newly on a different position. 2.3 An occasional unclear of length marking is permitted if both of the neighboring markings are clear; 2.4 The both cable ends are sealed with heat shrinkable end caps to prevent water ingress. Page 2 of 6

2.5 Fiber color code No. 1 2 3 4 5 6 Color Blue Orange Green Brown Gray White No. 7 8 9 10 11 12 Color Red Black Yellow Violet Pink Aqua No. 13 14 15 16 17 18 Color Blue+R Orange+R Green+R Brown+R Gray+R White+ R No. 19 20 21 22 23 24 Color Red+R Natural+R Yellow+R Violet+R Pink+R Aqua+ R * R means ring mark. 2.6 Cable structure and parameter Fiber number Tube diameter Copper wire diameter Sheath thickness (nominal*) Overall diameter (nominal**) Weight (approx.) mm mm mm mm kg/km 2~6 2.5 1.4 2.9 8.3 77 8~12 3.0 1.4 2.9 8.8 83 14~24 3.6 1.4 2.9 9.4 92 * The nominal sheath thickness may vary by 0.2 mm. ** The nominal outer diameter and height may vary by 0.2 mm. Page 3 of 6

3. Fiber Properties 3.1 The properties of single mode optical fiber (ITU-T Rec. G.652D) Item Specification Fiber type Fiber material Attenuation coefficient @ 1310 nm @ 1383 nm @ 1550 nm @ 1625 nm Point discontinuity Cable cut-off wavelength Zero-dispersion wavelength Zero-dispersion slope Chromatic dispersion Single mode Doped silica 0.36 db/km 0.32 db/km 0.19 db/km 0.30 db/km 0.05 db 1260 nm 1300 ~ 1324 nm 0.093 ps/(nm 2.km) @ 1288 ~ 1339 3.5 ps/(nm. km) nm @ 1271 ~ 5.3 ps/(nm. km) 1360 nm 18 ps/(nm. km) 22 ps/(nm. km) @ 1550 nm @ 1625 nm PMD Q (Quadrature average*) 0.2 ps/km 1 / 2 Mode field diameter @ 1310 nm Core / Clad concentricity error Cladding diameter 9.2 0.4 um 0.5 um 125.0 0.7 um Cladding non-circularity 1.0% Primary coating diameter 245 10 um Proof test level 100 kpsi (=0.69 Gpa), 1% Temperature dependence 0 o C~ +70 o C @ 1310 & 1550nm 0.1 db/km * PMD Qis a link of 20 cable sections (M) and a probability level of 0.01% (Q). 4. Characteristic of Optical Cable 4.1 Mechanical & environmental characteristics 4.1.1 Cable bending radius: 10 x cable diameter (during operation) 20 x cable diameter (during installation) 4.1.2 Temperature range Operating temperature range -10 o C to +60 o C Storage / Transport temperature range Installation temperature range -10 o C to +70 o C 0 o C to +50 o C Page 4 of 6

4.2 Main mechanical & environmental characteristics test NO ITEM TEST METHOD ACCEPTANCE REQUIREMENTS 1 Tensile Strength IEC 794-1-E1 - Load: 600 N - Length of cable under load: 50m 2 Crush Test IEC 60794-1-E3 - Load: 300 N/100mm - Load time: 1min 3 Impact Test IEC 60794-1-E4 - Points of impact: 5 - Times of per point: 5 - Impact energy: 1.0Nm - Radius of hammer head: 12.5mm - Impact rate: 2sec/cycle 4 Repeated Bending IEC 60794-1-E6 - Bending Dia.: 20 x OD - Load: 150N - Flexing rate: 3sec/cycle - No. of cycle: 30 5 Torsion IEC 60794-1-E7 - Length: 1m - Load: 150N - Twist rate: 1min/cycle - Twist angle: ±180 - No. of cycle: 10 6 Water Penetration IEC 60794-1-F5B - Height of water: 1m - Sample length: 3 m - Time: 1 hour - No water shall have leaked from the opposite end of cable 7 Temperature Cycling IEC 60794-1-F1 - Temperature step: +20 o C -10 o C +60 o C +20 o C - Time per each step: 12 hrs - Number of cycle: 2 8 Compound Flow IEC 60794-1-E14 - Sample length: 30 cm - Temp: 70 C 2 C - Time: 24 hours - No compound flow 9 Sheath High Voltage Test - On line test - 9t KV (t-sheath thickness) - No sheath breakdown 5. Packing and Marking Page 5 of 6

5.1 Packing 5.1.1 Each single length of cable shall be reeled on Non-fumigated Iron-wooden Drum suitable for long distance shipment. 5.1.2 Covered by plastic buffer sheet. 5.1.3 Sealed by strong wooden battens. 5.1.4 At least 1 m of inside end of cable will be reserved for testing. 5.1.5 Drum length 5.1.5.1 Standard drum length is 4000m±3%; 5.1.5.2 Single length not less than 95% of standard length per drum shall be permitted for quantity not exceeding 10% of the total supply; 5.1.5.3 Total quantity is at least the ordered quantity. 5.2 Drum Marking 5.2.1 Cable drum - Manufacturer brand; - Roll-direction arrow; - Cable outer end position indicating arrow; - The word OPTICAL FIBER CABLE ; - Origin, The word MADE IN CHINA ; - Caution plate indicating the correct method for loading, unloading and convey the cable; - Other customer information such as contract no., project no., and delivery destination. (if needed) 5.2.2 Marking plate - Product name; - Cable type and size; - Drum length; - Gross / Net weight in kilograms; - Drum number in meters; - Manufacturer's name; - Manufacturing year and month; - Project number, contract number or purchasing order number (if needed). 5.2.2 Cable identification documents - Test report. -----------End---------- Page 6 of 6