GLB...9. Ball Valve actuators. Building Technologies HVAC Products. for valves VAI61... AC 24 V / AC 230 V

Similar documents
Rotary actuators for ball valves

Rotary actuators for ball valves

Rotary actuators for ball valves

Rotary actuators for ball valves

Rotary actuators for ball valves

Air damper actuators Rotary version with spring return, AC 24 V / DC V / AC 230 V

Rotary actuators for ball valves

Air damper actuators

Air damper actuators. OpenAir GDB..1E. Electronic motor driven actuators for open-close, three-position and modulating control

Configured air damper actuators 6FU11xx-xDxxx-xxxx

Air damper actuators. OpenAir GSD...1A. Electric motor-driven rotary actuators for open-close, three-position and modulating control

OpenAir Linear actuators GDB/GLB...2 Technical basics. CE1Z4664en Building Technologies

Electromotoric actuators

SAT.. Electromotoric actuators for valves ACVATIX. with a 5.5 mm stroke and 300 N positioning force

SAL.. ACVATIX Electromotoric rotary actuators for butterfly or slipper valves. with 90 rotary angle

SAX.. ACVATIX Electromotoric actuators for valves. with a 20 mm stroke

SAX.. Electromotoric actuators for valves ACVATIX. with a 20 mm stroke

SAX.. ACVATIX Electromotoric actuators for valves. with a 20 mm stroke

Electromotoric actuators for stroke valves

Power consumption In operation At rest For wire sizing. 1.5 W at nominal torque 0.4 W 4 VA Connection Cable 1 m, 3 x 0.75 mm 2

SAV.. ACVATIX Electromotoric actuators for valves. with a 20/40 mm stroke

SAX..P. Electromotoric actuators for valves ACVATIX. with a 20 mm stroke

Overview of types. Technical data. T5-NRDVX24-SR-T-.. en v Subject to changes 1 / 3

SAY..P.. A6V ACVATIX Electromotoric actuators for VPI46. with a 15 mm stroke

Technical data. Safety notes. T3-LR24A-SR en v Subject to changes 1 / 2

Power consumption In operation At rest For wire sizing. 150 s / C Sound power level Motor. Emergency setting function 61 db (A)

Technical data. T2-SM230ASR en v Subject to changes / 3. Electrical data Nominal voltage AC

M7061 ROTARY VALVE ACTUATORS

Power consumption In operation At rest For wire sizing. Auxiliary switch NRF24A-SR-S2 NRF24A-SR-S2-O

DCS-62 Series Spring Return Electronic Actuator Product Bulletin

Technical Instructions Document No EA GQD June 23, OpenAir

SAY..P.. A6V ACVATIX Electromotoric actuators for valves. with a 15 mm stroke

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V. Power consumption In operation At rest For wire sizing

Electromotoric actuators for valves

Rotary gear motor series AG8...

Technical data V phase cut, input impedance 8.2 k Position feedback (measuring voltage U) DC V, max. 0.5 ma Start point DC

OpenAir Electric Damper Actuators GDE/GLB Series Non-spring Return Rotary 24 Vac - Modulating Control 0 to 10 Vdc

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Outside Temperature Sensors

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Technical Instructions Document No EA GQD October 25, OpenAir GQD Series

Technical data. Safety notes

Power consumption In operation At rest For wire sizing

Functional data Factory settings Variable Settings

Electronic Air / Fuel Ratio Control System

[ ] kvs theor.: Theoretical kvs value for pressure drop calculation Vmax low-n: Vmax for low-noise operation

FA-3300 Heavy Duty Electric Actuator. Features and Benefits. FA-3300 Actuator with VG8000 valve. Constant running time. Fixed close-off force.

Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool

21 VA (l max 20 5 ms) Connection Cable 1 m, 4 x 0.75 mm 2 Functional data Factory settings Variable Setting Torque Inhibiting torque

Technical data sheet. Technical data. Safety notes

Room Sensors. In ventilating and air conditioning plants to acquire relative humidity and temperature in rooms. Humidity measuring range

Room Sensors. for relative humidity and temperature

QFM21... Duct sensors. Symaro. for relative humidity and temperature

Power consumption In operation At rest For wire sizing

AC/DC 24 V, 50/60 Hz. Functional data Variable Settings. DC V, max. 0.5 ma. End point DC V... 4 ma ma Non-variable

Power consumption In operation At rest For wire sizing

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC 230 V Nominal voltage frequency

SQM5 Reversing Actuators, with Multiple Analog Control Input Signals

Overview of types. Technical data

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Technical data. Parameterisable damper actuator in the

Room Temperature Controllers. for heating and cooling systems

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Explosion proof rotary actuator - On/Off or programmable regulating actuator

Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Technical data. Safety notes. Power consumption In operation At rest For wire sizing

Rudder or propeller angular position transmitter KINAX WT720

Room sensors. In ventilating and air conditioning plants to acquire relative humidity and temperature in rooms. Humidity measuring range

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Technical data. Safety notes. T5-HT24-SR-T en v Subject to changes 1 / 3

Room Temperature Controllers. for heating and cooling systems

Room Temperature Controllers. for heating and cooling systems

Provides line voltage capable single Pole Double-Throw (SPDT) switch and 140Ω, 1KΩ, 2KΩ or 10KΩ feedback potentiometric.

Spring Return DuraDrive Proportional Actuator

s Climatix extension module 26 I/Os POL985.00/XXX

Differential pressure sensors

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Servomotor for butterfly valves VF, VFH. delta-elektrogas.com EE157-01/16

Modulating controlled actuators AME 10, AME 20, AME 30 AME 13, AME 23, AME 33 - with DIN EN certified safety function (spring down)

/2 way motorised valves

Modulating control valves with magnetic actuator, PN 16

Zelio Control Measurement Relays

Room Temperature Sensors

Rotary Measuring Technology

Type 3374 Electric Actuator

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Room Temperature Controllers. for heating and cooling systems

Incremental encoders Blind or through hollow shaft ø12 mm pulses per revolution

Actuators for modulating control AME 85, AME 86

11 VA Connection Cable 1 m, 4 x 0.75 mm 2 Functional data Factory settings Variable Setting Torque (nominal torque) Motor Spring return

EC centrifugal fan - RadiCal

EC centrifugal fan. backward curved, single inlet

Power consumption Operation At rest Wire sizing

82880 series 2/2-way motorised valves

Transcription:

4 657 Ball Valve actuators GLB...9 for valves VAI61... / Electronic motor driven actuators for three-position and modulating control, pre-wired with 0.9 m long connection cables. Remarks This data sheet provides a brief overview of these actuators. Please refer to the Technical Basics in document Z4634en for a detailed description as well as information on safety, engineering notes, mounting and commissioning. Use For 2-Port threaded ball valves from DN15 to DN50 Suitable for use with modulating controllers () or three-position controllers. C2N4657E 25.02.2008 Building Technologies HVAC Products

Type summery Operating voltage Operating voltage Positioning signal Y DC 0...35 V with characteristic function Uo, ΔU Position indicator U = Feedback potentiometer 1 kω Self-adaption of rotational angle range Auxiliary switches (two) Rotary direction switch GLB131.9E GLB 331.9E GLB 161.9E Use standard GLB163.1E plus ASK77.3 Use standard GLBx32.1E plus ASK77.3 Use standard GLBxx6.1E plus ASK77.3 Functions Type GLB131.9 GLB331.9 Control type Three-position control odulating control Clockwise or counter-clockwise direction depends... on the type of control. With no...on the setting of the rotary direction Rotary direction power applied, the actuator remains in DIL switch clockwise / counterclockwise the respective position. Signal on Y1 counterclockwise valve opens Signal on Y2 rotation clockwise valve closes DIL 2 set to counter-clockwise Flow = 0 at Y = 0 V Flow = 100% at Y = 10 V Position indication: echanical Position indication: Electrical anual adjustment Rotary angle position indication by using a position indicator. Position indicator: Output voltage U = is generated proportional to the rotary angle. U depends on the rotary direction of the DIL switch setting. The actuator can be manually adjusted by pressing the gear train disengagement button The actuators are suitable for operation of the following Siemens two-port and threeport valves: Type reference DN PN class k vs [m 3 /h] 2-port valves VAI (control or safety shutoff valves) VAI61.15 Rp ½ 15 1 10 VAI61.20 Rp ¾ 20 4 10 VAI61.25 Rp 1 25 6.3 16 VAI61.32 Rp 1 ¼ 32 PN40 10 25 VAI61.40 Rp 1 ½ 40 16 40 VAI61.50 Rp 2 50 25 63 Data sheet N4211 2/5 Building Technologies ball valve actuators, non spring return versions, / C2N4657E

Ordering Note Accessories, spare parts Potentiometer and auxiliary switches cannot be added in the field. For this reason, order the type that includes the required options. For functionally extend the ball valve bracket can be ordered separate and combined with a standard OpenAir-Actuator. Possible combinations ASK77.3 with Floating 230 V Floating 24 V Proportional Auxiliary switches (two) GLB336.1E GLB136.1E GLB166.1E Feedback potentiometer 1 kω GLB332.1E GLB132.1E DC 0...35 V with characteristic function Uo, ΔU - - GLB163.1E For more details about these actuators see datasheet N4634 Notes ounting For more details about these actuators see N4634 Both valve and actuator can easily be assembled at the mounting location. Neither special tools nor adjustments are required. The valve is supplied with ounting Instructions xxxxxxx. Orientation 90 90 Commissioning 4716Z16 When commissioning the system, check wiring and the functions of the actuator. Operation Caution Before testing the functioning of the actuators, always check to ensure that the actuator concerned is mounted on a valve (refer to «Equipment combinations»). The lever can be used to drive the actuator into any position between 0 and 1. push the slider on side and move the lever. If a control signal from the controller is present, this will take priority in determining the position after the slider is released. Technical data GLB..9E supply (SELV/PELV) Operating voltage / Frequency Power consumption GLB131.9 Running Running Holding ± 20 % / 50/60 Hz 2 VA / 1 W 3 VA / 2 W 1 W supply Function data Operating voltage / Frequency Power consumption GLB331.9 Running Nominal torque aximum torque (blocked) Nominal rotary angle / ax. rotary angle Runtime for 90 rotary angle ± 10 % / 50/60 Hz 2 VA / 1 W 10 Nm (GLB)/ 19 Nm (GLB) 90 / 95 ± 2 150 s (50 Hz) / 125 s (60 Hz) Building Technologies ball valve actuators, rotary versions, / C2N4657E 3/5

Positioning signal for GLB16..9 Characteristic functions for Input voltage Y (wires 8-2) ax. permissible input voltage Input voltage Y (wires 8-2) Non-adjustable characteristic function DC 35 V, internally limited to DC 10 V DC 0...35 V Position indicator Connection cables Degree of protection of housing Protection class Environmental conditions Standards and directives Weight Output voltage U (wires 9-2) ax. output current Cross-section Standard length Degree of protection as per EN 60 529 (note mounting instructions) IP 54 Insulation class, feedback potentiometer, auxiliary switch Operation / Transport Temperature Humidity (non-condensing) Product safety: Automatic electrical controls for household and similar use Electromagnetic compatibility (EC): Immunity for all models GLB131.9E and 161.9E Emission for all types Conformity: Electromagnetic compatibility Low voltage directive Conformity: Australian EC Framework Radio Interference Emission Standard Without packaging: DC ± 1 ma 0.75 mm 2 0.9 m EN 60 730 lll ll IEC 721-3-3 / IEC 721-3-2 32...+55 C / 32...+70 C < 95% r. F. / < 95% r. F. EN 60 730-2-14 (Type 1) IEC/EN 61 000-6-2 IEC/EN 61 000-6-3 89/336/EWG 73/23/EWG Radio Communication Act 1992 AS / NZS 3548 0.48 kg Disposal Internal diagrams The document on technical basics and the environmental declaration provide information on environmental compatibility and disposal of this device. Three-position control GLB131.9 GLB331.9 AC 0 V G.B13.. 6 7 (Y1) (Y2) 6 7 (Y1) (Y2) (G) 1 4634Gxx3 (N) 4 odulating control SELV/PELV G.B16.. 1 8 (G) (Y) 100% 0% (G0) (U) 2 9 4634Gxx1 Cable labeling Pin Cable Code No. Color Abbreviation eaning Actuators G 1 red RD System potential G0 2 black BK System neutral Y2 6 purple VT Position signal AC 0 V, clockwise Y1 7 orange OG Position signal AC 0 V, counter-clockwise Y 8 grey GY Position signal DC 0..10 V, 0..35 V U 9 pink PK Position indication Actuators N 4 blue BU Neutral conductor AC 230V Y2 6 black BK Control signal, clockwise Y1 7 white WH Control signal, counter-clockwise 4/5 Building Technologies ball valve actuators, non spring return versions, / C2N4657E

Dimensions 87.5 112.4 73.8 108 143.2 cm Dimensions in mm = > 100 mm = > 200 mm inimum clearance from ceiling or wall for mounting, connection, operation, maintenance etc. 2008 Siemens Switzerland Ltd. Subject to alteration 5/5 Building Technologies ball valve actuators, rotary versions, / C2N4657E