The LHCb VELO Upgrade. Stefano de Capua on behalf of the LHCb VELO group

Similar documents
PoS(VERTEX2015)008. The LHCb VELO upgrade. Sophie Elizabeth Richards. University of Bristol

PoS(Vertex 2016)071. The LHCb VELO for Phase 1 Upgrade. Cameron Dean, on behalf of the LHCb Collaboration

The LHCb Upgrade BEACH Simon Akar on behalf of the LHCb collaboration

The VELO Upgrade. Eddy Jans, a (on behalf of the LHCb VELO Upgrade group) a

arxiv: v1 [physics.ins-det] 25 Feb 2013

The LHCb Vertex Locator (VELO) Pixel Detector Upgrade

The LHCb VELO Upgrade

K. Akiba on behalf of the VELO and UT groups

arxiv: v2 [physics.ins-det] 24 Oct 2012

Pixel sensors with different pitch layouts for ATLAS Phase-II upgrade

The LHCb Vertex Locator : Marina Artuso, Syracuse University for the VELO Group

The LHCb VELO Upgrade

Status of the LHCb Experiment

The LHCb VELO Upgrade

A new strips tracker for the upgraded ATLAS ITk detector

VErtex LOcator (VELO)

VELO: the LHCb Vertex Detector

Physics at the LHC and Beyond Quy Nhon, Aug 10-17, The LHCb Upgrades. Olaf Steinkamp. on behalf of the LHCb collaboration.

Pixel detector development for the PANDA MVD

ATLAS ITk and new pixel sensors technologies

The LHCb VELO Upgrade

Test Beam Measurements for the Upgrade of the CMS Phase I Pixel Detector

Silicon Sensor and Detector Developments for the CMS Tracker Upgrade

Layout and prototyping of the new ATLAS Inner Tracker for the High Luminosity LHC

PoS(LHCP2018)031. ATLAS Forward Proton Detector

The ATLAS tracker Pixel detector for HL-LHC

Development of Pixel Detectors for the Inner Tracker Upgrade of the ATLAS Experiment

CMS Tracker Upgrades. R&D Plans, Present Status and Perspectives. Benedikt Vormwald Hamburg University on behalf of the CMS collaboration

PoS(EPS-HEP2017)476. The CMS Tracker upgrade for HL-LHC. Sudha Ahuja on behalf of the CMS Collaboration

ATLAS strip detector upgrade for the HL-LHC

PoS(VERTEX 2009)037. The LHCb VELO Upgrade. Jianchun Wang 1

Track Triggers for ATLAS

Strip Detectors. Principal: Silicon strip detector. Ingrid--MariaGregor,SemiconductorsasParticleDetectors. metallization (Al) p +--strips

ITk silicon strips detector test beam at DESY

Stato del progetto RICH di LHCb. CSN1 Lecce, 24 settembre 2003

A High-Granularity Timing Detector for the Phase-II upgrade of the ATLAS Calorimeter system Detector concept description and first beam test results

BTeV Pixel Detector and Silicon Forward Tracker

What do the experiments want?

CMS Tracker Upgrade for HL-LHC Sensors R&D. Hadi Behnamian, IPM On behalf of CMS Tracker Collaboration

Phase 1 upgrade of the CMS pixel detector

The CMS HGCAL detector for HL-LHC upgrade

The upgrade of the ATLAS silicon strip tracker

Expected Performance of the ATLAS Inner Tracker at the High-Luminosity LHC

Thin Silicon R&D for LC applications

Overview of the LHCb Upstream Tracker (UT)

The LHCb Experiment. Experiment and what comes after. O. Ullaland Ljubljana January Theodor Kittelsen, Soria Moria (with modifications)

The Inner Tracker detector of the LHCb experiment.

Preparing for the Future: Upgrades of the CMS Pixel Detector

A silicon pixel detector for LHCb

Commissioning the LHCb VErtex LOcator (VELO)

Development of n-in-p Active Edge Pixel Detectors for ATLAS ITK Upgrade

Status of the LHCb experiment

LHCb: To Infinity and Beyond

Towards a 10 μs, thin high resolution pixelated CMOS sensor system for future vertex detectors

Julia Thom-Levy, Cornell University, for the CMS Collaboration. ECFA High Luminosity LHC Experiments Workshop-2016 October 3-6, 2016

The Compact Muon Solenoid Experiment. Conference Report. Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

Sensor production readiness

The Compact Muon Solenoid Experiment. Conference Report. Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

New fabrication and packaging technologies for CMOS pixel sensors: closing gap between hybrid and monolithic

Upgrade of the CMS Tracker for the High Luminosity LHC

The BaBar Silicon Vertex Tracker (SVT) Claudio Campagnari University of California Santa Barbara

A Characterisation of the ATLAS ITk High Rapidity Modules in AllPix and EUTelescope

A High Granularity Timing Detector for the Phase II Upgrade of the ATLAS experiment

CMS Phase II Tracker Upgrade GRK-Workshop in Bad Liebenzell


Summer Student project report

Resolution studies on silicon strip sensors with fine pitch

Operational Experience with the ATLAS Pixel Detector

Performance of the ATLAS Muon Trigger in Run I and Upgrades for Run II

The CMS Silicon Pixel Detector for HL-LHC

The Commissioning of the ATLAS Pixel Detector

LHC detector upgrade challenges

A High-Granularity Timing Detector for the Phase-II upgrade of the ATLAS Detector system

`First ep events in the Zeus micro vertex detector in 2002`

Silicon Sensor Developments for the CMS Tracker Upgrade

Beauty Experiments at the LHC

arxiv: v1 [physics.ins-det] 26 Nov 2015

Pixel hybrid photon detectors

High-Speed/Radiation-Hard Optical Links

Specifications of the RF box for the upgraded LHCb vertex detector

The High-Voltage Monolithic Active Pixel Sensor for the Mu3e Experiment

Studies of silicon strip sensors for the ATLAS ITK project. Miguel Arratia Cavendish Laboratory, University of Cambridge

ATLAS Pixel Detector Upgrade: IBL Insertable B-Layer

The LHCb Silicon Tracker

arxiv: v2 [physics.ins-det] 20 Oct 2008

Monolithic Pixel Sensors in SOI technology R&D activities at LBNL

Construction and Performance of the stgc and Micromegas chambers for ATLAS NSW Upgrade

LHCb Preshower(PS) and Scintillating Pad Detector (SPD): commissioning, calibration, and monitoring

Design and Construction of Large Size Micromegas Chambers for the ATLAS Phase-1 upgrade of the Muon Spectrometer

The LHCb Inner Tracker

ATLAS Muon Trigger and Readout Considerations. Yasuyuki Horii Nagoya University on Behalf of the ATLAS Muon Collaboration

Operation and performance of the CMS Resistive Plate Chambers during LHC run II

D. Ferrère, Université de Genève on behalf of the ATLAS collaboration

The CMS Pixel Detector Phase-1 Upgrade

Richard L. Bates SUPA, School of Physics and Astronomy, Glasgow University, Glasgow, G12 8QQ, UK

Development of a Highly Selective First-Level Muon Trigger for ATLAS at HL-LHC Exploiting Precision Muon Drift-Tube Data

Results of FE65-P2 Pixel Readout Test Chip for High Luminosity LHC Upgrades

Installation, Commissioning and Performance of the CMS Electromagnetic Calorimeter (ECAL) Electronics

CMOS Detectors Ingeniously Simple!

Production of HPDs for the LHCb RICH Detectors

Transcription:

The LHCb VELO Upgrade Stefano de Capua on behalf of the LHCb VELO group

Overview [J. Instrum. 3 (2008) S08005] LHCb / Current VELO / VELO Upgrade Posters M. Artuso: The Silicon Micro-strip Upstream Tracker for the LHCb Upgrade R. Quagliani: SciFi - A large Scintillating Fibre Tracker for LHCb D. Saunders: The Timepix3 Telescope and LHCb Upgrade R&D measurements 2

Overview RICH Calorimeter VELO Tracking stations either side of a 4 Tm dipole magnet Muon system VErtex LOcator is a silicon detector surrounding the collision region, providing excellent impact parameter resolution identification of secondary vertices [J. Instrum. 9 (2014) P09007] 3

The current VELO microstrip detector base p beam vacuum 6 cm x y injection stable beams z y x p RF box module 2 retractable detector halves at 5 (30) mm from beam when closed (open). 21 stations per half with an R and sensor. First active strip @ 8 mm from the beam. Operates in secondary vacuum. 300 mm foil separates detector from beam vacuum. CO 2 cooling system (Operates @ -30 C, Sensors @ -10 C). 4

LHCb Upgrade concept Precision of many physics measurements at LHCb will be statistically limited at end of Run II: Increase luminosity to boost statistics: 4x10 32 cm -2 s -1 2x10 33 cm -2 s -1 50 fb -1 expected after LS2 2011 2012 many hadronic channels saturate, due to energy cuts in the trigger 16 June 2016 Manchester Group Meeting Remove hardware trigger 1 MHz 40 MHz readout rate Data taking starting in 2021 (Run III) [CERN-LHCC-2012-007] 5

VELO Upgrade To be operated @ 40 MHz and 2x10 33 cm -2 s -1 and at 5 mm from the beams 10 data rates 10 max fluence sensors to be kept @ -20 o C current VELO VELO upgrade Improve detector performance track reconstruction resolution The plan: new pixel detector no ghost tracks faster reco algorithm new front-end electronics thinner RF-foil more efficient cooling interface [CERN-LHCC-2013-021] VELO Module 6

VELO Upgrade in numbers Feature VELO Upgrade Sensors R & strips 0.22 m 2 172,032 strips electron collecting 300 mm thick Pixels 0.12 m 2 41 M pixels electron collecting 200 mm thick # of modules 42 52 Max fluence 1.3 10 14 MeV n eq cm -2 8 10 15 1 MeV n eq cm -2 HV tolerance 500 V 1000 V ASIC Readout rate 1 MHz 40 MHz Total data rate 150 Gb/s 2.8 Tb/s Total Power consumption 1 kw 1.6 kw (30 W/module) 7

VELO Upgrade Module concept CF rods CO 2 cooling pipes kapton hybrid Si micro-channels cooling plate data tapes cooling connector Si sensors (4 per module) 8

Micro-channel cooling interface baseline: silicon substrate metallized with Ti+Ni+Au same CTE as sensors + low material budget routing of channels customizable pressure: 14 bar @ -30 o C, 60 bar @ 22 o C, (to be qualified at 180 bar) 120 200 mm micro-channels (19 ) 60 60 mm high impedance restrictions cooling power > 36 W 9

Cooling interface prototype Prototype design close to real layout thermal capacity = 1 VELO module Pyrex-Silicon sample first full-size plates in March 2017 10

Aluminium RF-foil Accommodate modules Vacuum tight Light (300 mm 250 mm) Corrugated Thermally stable Rad-hard Al mold 1 mm smaller than box Mill inside of box Mill outside of box Half box prototype 11

y [mm] ~ 15 mm Sensors Sensor is bump-bonded to 3 VeloPix ASICs sensor 256 x 256 pixels, 55 x 55 mm pixel size with elongated pixels (137.5 mm) in the region between ASICs Sensor baseline: n-on-p 200 mm thickness ~ 43 mm VeloPix: up to 900 Mhits/s (data driven readout) number of hits (a.u.) x [mm] 12

Testbeam campaign 2014-15 Rigorous series of testbeams to qualify the sensors Velo Sensors must collect at least 6000 e - /MIP @ 99% efficiency At 50 fb -1 8 10 15 1 MeV n eq cm -2 (or 370 MRad) ATLAS IBL @ 550 fb -1 = 3.3 10 15 1 MeV n eq cm -2 (or 160 MRad) Non-uniformity of radiation dose (factor 100 edge-to-edge) Testing HPK and Micron: n-in-p (200 mm) n+-in-n (150 mm) 250-600 mm guard ring sizes 35-39 mm implant widths Sensors bump-bonded to Timepix3 ASICs Sensors irradiated (2-8 10 15 MeV n eq cm -2 ) in 5 different facilities with neutrons (uniform) and protons (non uniform) 13

Testbeam campaign 2014-15 Conditions: bias voltage: 300 V irradiaton: 8 10 15 1 MeV n eq cm -2 sensor thickness : 200 mm pixel corner (18 18 mm) Intra-pixel efficiency on neutron-irradiated sensors: Decreases in the corners at low bias. Scales with implant width. For normal incidence tracks. Efficiency reaches 99% at 1000 V. baseline: 39 mm implant 14

Summary The new VELO will have to cope with 10 radiation and 10 data rates. New module design based on pixels sensors mounted on a Si microchannel substrate. Bi-phase CO 2 micro-channel prototype performs as expected. Aluminium RF-foil prototypes progressing well. Sensor tiles irradiated and extensively characterised in test-beams. VeloPix ASIC submitted in May 2016. Install in LHC Long Shutdown 2 and take data in Run III sensors VeloPix assembly m-channels 15

Thanks 16

Spares 17

The LHCb detector ~20 µm IP resolution @ p T > 2 GeV σ m ~8 MeV for B + J/K +, 25 MeV for Bµ + µ- Excellent muon identification = 97%, misid 2% (K K) 90% for (K ) <10% σ(e)/e ~ 10%/ E 1% σ m ~90 MeV for B 0 K * 18

LHCb Upgrade VELO Si strips (replace all) Silicon Tracker Si strips (replace all) Outer Tracker Straw tubes (replace R/O) Muon MWPC (almost compatible) RICH HPDs (replace HPD & R/O) Calo PMTs (reduce PMT gain, replace R/O) 19

20 Alignment VELO halves centered around beam at each fill, when beams declared stable. Beam position determined from vertex reconstruction with tracks in right or left half. Misalignment from distance between the two reconstructed vertices. Fully automated procedure (~210 s). Stable within ±5 mm (x). DPVx DPVy 2010 2010

21 Performance Single hit S/N IP Single hit resolution: linear dependence on the strip pitch in projected angle bins. better resolution for larger angles. IP resolution of ~13 mm for infinite momentum tracks. S/N(R) 19, S/N(F) 21

22 Performance PV 13 mm Excellent cluster finding efficiency: CFE = 99.51 ± 0.02 % [all channels] CFE = 99.98 ± 0.02 % [bad strips excl, 0.77%] PV resolution of 13 mm for 25 tracks (typical case). Excellent tracking efficiency.

23 Testbeam Timepix telescope Designed for the LHCb upgrade Composed by 9 Timepix assemblies (with 300 mm thick sensors) DUT can be moved/rotated and cooled Resolution at DUT plane < 2 mm Focus on: sensor performance after irradiation (Medipix3) evaluation of guard-rings, edge efficiency prototype strip module

m-channel wafer bonding 24

25 X-ray imaging of soldering samples Sample pictures (good and bad):

expected performance after irradiation 26

VeloPix & DAQ Derived from Timepix3 ASIC. Based on 130 nm CMOS technology (TSMC). Data-driven readout. 2 4 pixels grouped to SuperPixel. Timepix3 is general purpose. VeloPix is optimized for speed: VELO will produce 3 Tbit/s. Radiation hardness and SEU robustness. Binary hit information. Data gathered in SuperPixels: shared BCID and address 30% data reduction SP data propagated downwards: arbiter decides who can send. time continuity lost. Back end electronics must cope with a huge amount of data: TELL40 (upgrade of TELL1, current DAQ board) receives and builds events using FPGAs. All the information is assembled and passed on to computing farm, stripping down redundant data. Further processing and full reconstruction in the trigger farm. 27

28 PlanB 2 pieces 25 mm thick of poco foam HTC with milled profile for capillary, glued together 12 W