FOM-4SF Sync/Async Single Fiber Modem

Similar documents
FOM-5A, 6A Asynchronous Fiber Optic Modems

Miniature Synchronous Multipoint Modems

PRODUCT INFORMATION B&B ELECTRONICS. Port-Powered RS-232 Fiber Optic Modem with Handshake Support. Model 9PFLST. Description. RS-232 Connections

Interface: Serial EIA RS-232D/CCITT V.24, DCE; RTS/CTS delay 0,8 or 64 ms (user-selectable).

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

Part Numbers. Fiber Driver - ST/DB25M FIBER DRIVER

285E Series DIGITAL FIBER OPTIC AUDIO/DATA TRANSPORT SYSTEM

SOLUTIONS FOR AN EVOLVING WORLD. T1/E1 and C Fiber Service Units

Installation and Operation Manual HS-R. 4-Channel Low Speed Data Module with V.110 Rate Adaptation MEGAPLEX-2100 MODULE

F290X / F293X FOM II Series Fiber Optic Isolator Technical Manual

[ tima-datasheet-en v11.1 ]

RS 485/422 to Fibre Optic Modems ELO E243, ELO E244, ELO E245. Operation manual

INDUSTRIAL OPTO-ISOLATED RS-232 REPEATER

AccessCON-N64 INTERFACE CONVERTER E1/FRACTIONAL E1 TO N64 INSTALLATION AND OPERATION MANUAL. Version 1

LDM85. Fiber Optic Modem. Description. Features. Specifications

Digital Microwave Radios

CM /100/1000BASE-T

USER MANUAL MODEL 1186 Multi-Mode Fiber Modem with Fixed G.703/G.704 Interface

Atrie WireSpan 600/610 MODEM User's Manual

CONTROL MICROSYSTEMS SCADAWave Radio Transceiver. Hardware Manual

4 Channel Contact Closure DIN Fiber Link System

Modem E1. Modem-converter E1-L. Features. Contents

MEGAPLEX-2100 MODULE VC-16A. 16-Channel PCM/ADPCM Voice Module Installation and Operation Manual. Notice

SWT 3000 Teleprotection technical data siemens.com

USER MANUAL MODEL Parallel to Serial/ Serial to Parallel Interface Converter

Selection guide. Communication accessories. Communication accessory selection guide. Characteristics

4 Channel 4~20mA / 0~10VDC Analog DIN Fiber Link System

ADA User manual ADA Multimode Fibre-Optic to Current Loop Converter

VC-4/4A, VC-8/8A, VC-16 4/8/16-Channel PCM and ADPCM Voice Modules

Moxa ICF-1280I Series Industrial PROFIBUS-to-Fiber Converter

User Manual. Canoga Perkins 2262 T1/E1 Fiber Optic Modem

ADA-1028L. User manual ADA-1028L. RS232 to Current Loop 2-wire CLO Converter. 1 io_ada-1028l_v.1.10_en. Copyright CEL-MAR sp.j.

Model FLSC-C3-XX. DC Powered Microprocessor Controlled Transmitter

TMX PRODUCT LINE: 4-Channel Multiplexer. CATEGORY: ISDN and T/E Carrier. S/T-Interface DS0, DS1, T1, E1, DS1C, T1C, DS2, T2, E2 FEATURES

Airmux-200 Wireless Broadband Multiplexer

SISNet Distance Extenders

Instruction Manual Model Upconverter

Kilomux-2100/2104 KVF.4 2-Channel Low Bit Rate Voice/Fax Module

PDL Base. Radio Modem User's Guide. Revision 0.2 (preliminary) May 1999 Copyright 1999 Pacific Crest Corporation Document M00522

Active UTP Transceiver Hub Installation Guide

ControlNet Modular Repeater Medium Distance Fiber Module

Cisco Smart SFP Network Interface Device

Instruction Manual Model Upconverter

ADA User manual ADA RS-232 to RS-485 / RS-422 Converter

SEL Serial Radio Transceiver. The industry-recognized standard for reliable, low-latency wireless communications

satech SynchroStar GPS 200 Series

Product Specification. 6.1 Gb/s Short-Wavelength SFP+ Transceiver FTLF8526P3BNL

VC-6 6-Channel PCM Voice Module MEGAPLEX-2100 MODULE

PRetrans Table of contents

Trio K-Series. License-free serial data radio KR900 KR240 KP900 KP240 KB900 KB240

Non-Powered Interface Converters RS-232 to RS-530 RS-422 to V.35 RS-232 to RS-485 RS-232 to RS-422/RS-449

Modem 9600 baud 500FSD11 EDS500 series - FSK modems

SPECIAL SPECIFICATION 6744 Spread Spectrum Radio

The Price Performance Leader in 100% Compatible Optical Transceivers

The Price Performance Leader in 100% Compatible Optical Transceivers

GPNP Inc. NT384 NT1 User Manual. Revision /6/2002. Information in this guide is subject to change without notification.

DSP4xxFP SA USER S MANUAL. A01561 Rev. A. This Manual covers all configurations of the DSP4xxSA Modem with the Serial Number SA and up.

10Gbps 1550nm 80KM SFP+ Optical Transceiver 10Gbps 850nm 300M SFP+ Optical Transceiver

OC-48 LR-2/STM L-16.2 RoHS Compliant Pluggable SFP Transceiver

Airmux-400 Specifications

Since 1987 Developed, Created and Made in Spain NDV5/ND5V VIDEO & DATA TRANSMITTER/RECEIVER

MODEL: DLS. Telemetering System

5 Mbit/s Repeater Carrierband to Single-mode Fiber Optic

Installation and Operation Manual VC-6A. 6-Channel PCM/ADPCM Voice Module MEGAPLEX-2100 MODULE

FSW-1650 FSW User Manual. 16/24-Port 10/100 Rackmount Switch

Appendix A: Specifications

AMB-1200C Deactivator Controller and AMB-1200A Countertop Antenna

WIRELESS MODBUS GATEWAY WGW410

Airmux-400 Broadband Wireless Multiplexer

Encoder - Absolut 2RMHF-SSI

Product Specification Gb/s RoHS Compliant Short-Wavelength 2x7 SFF Transceiver. FTLF8524E2xNy

Since 1987 Developed, Created and Made in Spain NDV6/ND6V VIDEO & DATA TRANSCEIVER, AUDIO & CONTACT

Product Specification. OC-12 IR-1/STM S-4.1 RoHS Compliant Pluggable SFP Transceiver. FTLF1322P1xTR

CP485-4 User s Manual

Product Specification. 2 Gb/s RoHS Compliant Long-Wavelength Pluggable SFP Transceiver. FTLF1619P1xCL

TVB-2 INSTRUCTION SHEET. Test Verification Box

GE Interlogix Fiber Options S714D & S7714D. Instruction Manual FIBER-OPTIC NETWORK TRANSMISSION SYSTEM

The I-2532 CAN to Fiber Converter

PD30CNB25xxPS. Photoelectrics, Background suppression reflective - PointSpot. Main features. Main functions. Description

Stat-4 Stat-8 Stat-24

The Price Performance Leader in 100% Compatible Optical Transceivers GBIC-GE-S40K Part Number: GBIC-GE-S40K PRODUCT FEATURES APPLICATIONS

RuggedNet GPoE+/Si Unmanaged 4 and 8-Port PoE/PoE+ Switch. User Manual. 38 Tesla, Irvine, CA USA Phone: (949) ; Fax: (949)

HURRICANE Radio Modem. FULL DUPLEX Radio MODEM

F272xB Fiber optic 4-Wire Telephone/Audio Modem Technical Manual

MODEL FLD-496SA 9600 Baud FIBER OPTIC/FSK MODEM

OV-1000TSC OV-1000TLC/ Base-T to 1000Base-SX/LX Gigabit Ethernet Media Converter. User s Manual

(ES) Equipements Scientifiques SA - Département Réseaux sans fil rue de Buzenval BP Garches Tél Fax.

Installation and Operation Manual HS-Q/N. 4-Channel High Speed Data Module MEGAPLEX-2100 MODULE

Wireless Interface RAD-ISM-900-SET-BD-BUS Two-way (point-to-point) Monitoring and Control with Expandable I/O Options User Manual

Installing the IPS 4240 and the IPS 4255

Interface converter G kbit/sec

SCC-CO20 Isolated Current Output Module

R&S ZVT Vector Network Analyzer Specifications

10/100Base. 100Base-FX Switching Converter. User s Manual

USER MANUAL MODEL Time Division Multiplexor, RS-232 (CTS TDM-V.24) SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL G703FTEC. T1/E1 Cross Rate Converter

Series OLS10KD 10kW HIGH VOLTAGE POWER SUPPLY

Product Specification

Why Using Fiber for transmission

INSTALLATION AND OPERATING MANUAL

Transcription:

ORDERING FOM-4SF/$/+ Sync/async single fiber modem $ Specify DTE interface type: V24 for V.24 interface, female connector V35 for V.35 interface, female connector X.21 for X.21 interface, female connector 530 for RS-530 interface, female connector E1B for E1 (2048 kbps) balanced interface E1U for E1 (2048 kbps) unbalanced interface T1 for T1 (1544 kbps) interface + Specify fiber optic interface type: 85ST for 850 nm multimode, ST connector 85FC for 850 nm multimode, FC connector 85SC for 850 nm multimode, SC connector 13ST for 1300 nm single mode, ST connector 13FC for 1300 nm single mode, FC connector 13SC for 1300 nm single mode, SC connector P/S-AC/5/1200 5 VDC / 110 to 220 VAC, 1200 ma power supply P/S-AC/5/1200/GND 5 VDC / 110 to 220 VAC, 1200 ma power supply for FOM-4SF with balanced E1 or T1 interface 4SF-PS-FERRITE 5 VDC / 110 to 220 VAC, 1200 ma power supply for FOM-4SF with X.21 or RS-530 interface FOM-4SF Sync/Async Single Fiber Modem Specifications are subject to change without prior notice. 2001 RAD Data Communications Ltd. 318-100-01/01

FEATURES Miniature sync/async modem supporting half or full duplex transmission over single fiber cable Data rates up to 2048 kbps or E1/T1 (synchronous) or up to 115.2 kbps (asynchronous) V.24, RS-530, V.35, X.21, E1 or T1 DTE interface options 850 nm or 1300 nm LEDs on the link Internal, external or receive clock for serial DTE interfaces, and transparent timing for E1/T1 Local and remote V.54 diagnostic loopbacks LED status indicators Protection against reverse polarity Operates with external power supply APPLICATION DESCRIPTION FOM-4SF, miniature sync/async single fiber modem, transmits and receives data over a single fiber cable. The modem operates either in synchronous or asynchronous mode, and supports both half and full duplex communication. Transmission rates are as follows: Asynchronous: up to 115.2 kbps Synchronous: 64, 128, 256, 512, 1024 2048 kbps (serial or E1), or T1 (1544 kbps) FOM-4SF is available with the following DTE interfaces: V.24 RS-530 V.35 X.21 E1 balanced or unbalanced T1. FOM-4SF is available with either 850 nm LED for multimode transmission up to 3 km (1.9 miles), or 1300 nm LED for single mode transmission up to 25 km (15.5 miles). For V.35, V.24, RS-530 and X.21 interfaces operating in synchronous mode, transmit timing can be provided by three alternative sources: Internal oscillator External clock Loopback clock derived from the receive signal.

The E1 interface utilizes HDB3 line coding. The T1 interface utilizes B8ZS line coding. FOM-4SF performs diagnostic loopbacks in compliance with ITU V.54 standard. Two V.54 loopbacks are available: local loopback and remote loopback. These loopbacks are activated either by a DIP switch or via the corresponding DTE interface pins. The loopbacks can be activated separately or simultaneously. FOM-4SF incorporates all the advantages of a fiber optic system: Lower attenuation than with copper wires; attenuation is not related to frequency EMI/RFI immunity which saves the cost of expensive and heavy shielding and complex error checking routines High data security: risk of eavesdropping is minimized as fibers radiate negligible power; cost of data encryption is reduced Safety and electrical isolation: no spark hazard and no ground-loop noise problems. LED indicators enable status monitoring on the electrical and optical links. FOM-4SF operates with 5V/400 ma external power supply SPECIFICATIONS FIBER OPTIC INTERFACE Transmission Mode Multimode: 850 nm over 62.5µ/125 fiber optic cable Single mode: 1300 nm over 9µ/125 fiber optic cable Optical Output Levels -14 dbm Receiver Sensitivity -26 dbm for 1300 nm LED -28 dbm for 850 nm LED Operating Range Up to 3 km (1.9 miles) over 850 nm LED with attenuation of 3.5 db/km 62.5µ/125 fiber optic cable Up to 21 km (15.5 miles) over 1300 nm LED with attenuation of 0.5 db/km, 9µ/125 fiber optic cable Optical Interface ST, FC and SC (see Ordering) Latency 0.68 msec, minimum DTE INTERFACE Data Rates Asynchronous: up to 115.2 kbps Synchronous: 64, 128, 256, 512, 1024 2048 kbps (serial or E1), or T1 (1544 kbps) Data Format (Async Mode) 8, 9, 10, or 11 bits, including 1 start bit and 1 stop bit, with odd or even parity Type RS-530, V.24: DB-25 female connector V.35: provided via an adapter cable, terminated with a DB-25 connector on one end and a V.35 male or female physical connector on the other end X.21: provided via an adapter cable terminated with a DB-25 connector on one end, and an X.21 15-pin connector on the other end E1: RJ-45, balanced or two BNC coax, unbalanced T1: RJ-45, balanced (see Ordering) E1/T1 Standard E1 unframed, HDB3 coding T1 unframed, B8Z3 coding GENERAL LED Indicators V.24, V.35, RS-530 and X.21: PWR Power TST Test ELECTRICAL RX Electrical Receive ELECTRICAL TX OPTICAL LOS E1 and T1: PWR TST ELECTRICAL AIS ELECTRICAL LOS OPTICAL AIS OPTICAL LOS Electrical Transmit Optical Loss of Signal Power Test Electrical Alarm Indication Signal Electrical Loss of Signal Optical Alarm Indication Signal Optical Loss of Signal

Timing V.35, V.24, RS-530 and X.21: Internal External Receive E1 and T1: Transparent Power External 5V/400 ma power supply. Follow these guidelines to comply with electromagnetic requirements: For FOM-4SF with balanced E1 or T1 interface, use an external power supply with signal ground connected to chassis ground (see Ordering). For FOM-4SF with RS-530 or X.21 interface, install a ferrite core (Steward type 28A2025-0A2 or equivalent) on the cable, connecting the power supply to the modem, or order RAD's power supply with the ferrite core already installed (see Ordering). Physical Length: 100 mm / 3.9 in Height: 23 mm / 0.9 in Width: 53 mm / 2.1 in Weight: 140g / 4.9 oz Environment Temperature: 0 50 C / 32 122 F Humidity: Up to 90%, non-condensing Mfr. Name: Mfr. Address: Declaration of Conformity declares that the product: Product Name: FOM-4SF RAD Data Communications Ltd. 24 Raoul Wallenberg St. Tel Aviv 69719 Israel Conforms to the following standard(s) or other normative document(s): EMC: EN 55022 (1994): Limits and methods of measurement of radio disturbance characteristics of information technology equipment. EN 50082-1 (1992): Electromagnetic compatibility Generic immunity standards for residential, commercial and light industry. SAFETY: EN 60950/A4 (1996): Safety of information technology equipment, including electrical business equipment. Supplementary Information: The product herewith complies with the requirements of the EMC Directive 89/336/EEC and the Low Voltage Directive 73/23/EEC. The product was tested in a typical configuration. Tel Aviv, November 26th, 2000 Haim Karshen VP Quality European Contact: RAD Data Communications GmbH, Berner Strasse 77, 60437 Frankfurt am Main, Germany Safety Instructions The exclamation point within a triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance. IMPORTANT North American Users FOM-4SF is powered by an external power supply. To reduce the risk of electric shock, fire and injury to persons, use only with a UL listed or CSA certified Class 2 power supply rated 5 VDC, 400 ma. Instructions de Sécurité IMPORTANT Utilisateurs Au Canada Le FOM-4SF est renforcé par un transformateur extérieur. Afin de réduire le risque d'électrocution, d'incendie ou de blessure, utiliser seulement avec un transformateur 5 VDC, 400 ma certifié Class 2 CSA ou repris sur la liste UL.

CAUTION European Users To reduce the risk of electric shock and fire, use only with a power supply which is approved according to EN 60950. ACHTUNG Installation Bedieningsanleitung Um das Risiko eines elektrischenschlages oder Brandes so weit wie möglich zu vermeiden, verwenden Sie nur ein Netzteil, das gemäß der neuesten Version des Standards EN 60950 zugelassen ist. INSTALLATION Caution. Be careful when setting jumpers or performing any actions within the product so that you do not bend or break any components. Use an insulated tool to change switch settings. Installation of FOM-4SF is simple and straightforward. Follow these instructions: 1. Open the plastic case by pressing on the points indicated on the sides. 2. Configure FOM-4SF, using the DIP switches located on the modem's board (see Figure 1, Figure 2 and Table 1): Select the data rate. Select the timing reference. When working with E1 or T1 interface, enable the AIS option. In this case, FOM-4SF operates as follows: If an electrical LOS occurs, an AIS signal is transmitted toward the remote modem. If an optical LOS occurs, an AIS signal is transmitted toward the DTE. Note: The AIS setting of the two modems working opposite each other must be the same. Figure 1. DIP Switch Locations (FOM-4SF with V.24, RS-530, V.35 or X.21 Interface) Figure 2. DIP Switch Locations (FOM-4SF with E1 or T1 Interface)

Table 1. DIP Switch Selection Function Possible Settings Factory Setting To select data rate, SW 1-1, 1-2, 1-3 S1-1 S1-2 S1-3 Async OFF OFF OFF 64 OFF OFF ON 128 OFF ON OF 256 OFF ON ON 512 ON OFF OF 1024 ON OFF ON 2048 ON ON OFF 2048 kbps Notes: The SW 1-1, 1-2, 1-3 switches are available only for FOM-4SF with V.24, X.21, V.35 or RS-530 interfaces. The maximum data rate supported by the V.24 interface is 128 kbps. To select clock source, SW 3-1, 3-2 S3-1 S3-2 Internal OFF OFF Receive OFF ON External ON OFF Internal Notes: The SW 3-1, 3-2 switches are available only for FOM-4SF with V.24, X.21, V.35 or RS-530 interfaces. When using X.21 interface, set one modem to the internal clock, and configure the rest to the receive clock. FOM-4SF modems with E1 or T1 interface transfer timing signals transparently. To activate or deactivate a loopback, SW 2-1, 2-2 S2-1 S2-2 Normal Operation OFF OFF Local Loopback OFF ON Remote Loopback ON OFF Normal Operation To enable or disable the AIS transmission for E1 or T1 interface, SW 1-1 AIS Enabled AIS Disabled S1-1 ON OFF AIS Enabled

3. Connect the line: Remove the plastic dust cap from the fiber optic connector Connect the cable to the unit. 4. Connect the DTE: FOM-4SF with V.24, RS-530 interfaces: Plug the unit directly into the 25-pin connector of the DTE. Fasten the screws on each side of the modem connector. FOM-4SF with V.35 and X.21 interfaces: Connect the modem to the adapter cable. Fasten the screws on each side of the modem connector. Connect the other end of the adapter cable directly to the DTE and fasten the screws. FOM-4SF with balanced E1 or T1 interfaces: Connect the corresponding E1 or T1 cable line directly to the FOM-4SF RJ-45 connector. FOM-4SF with unbalanced E1 interface: Connect the DTE transmit cable to the FOM-4SF connector, designated OUT. Connect the DTE receive cable to the FOM-4SF connector, designated IN. 5. Connect the external power supply to the unit and then plug it into the main power. Wrap the power supply cord through the power stabilizer clip on the side panel of the modem. OPERATION Normal Operation For normal operation, make sure that the test and diagnostic switches (SW2-1 and SW2-2) are set to OFF (see Table 1). Diagnostic Loopbacks FOM-4SF performs two V.54 loopbacks: local loopback and remote loopback (see Figure 3, Figure 4 and Figure 5). Both loopbacks can be activated by the SW2-1 and SW2-2 switches. Alternatively, you can activate the loopbacks by raising the DTE interface pin 18 (local loopback), and pin 21 (remote loopback) for V.24 and RS-530 interfaces. When using the V.35 interface the loopback activating pins are pin JJ for LLB and pin HH for RLB. Local Loopback When a local loopback is activated in the local modem, the transmit signal of the local modem is looped back toward the modem's receive path and data received from the remote modem is ignored. The local loopback checks modem integrity on the local modem while continuing to send signals to the remote modem (see Figure 3). Figure 3. Local Loopback Remote Loopback When a remote loopback is activated from the local modem, the receive signal of the remote modem is looped back toward the modem's transmit path and data transmitted from the remote DTE is ignored; data continues to be sent over the DTE (see Figure 4). The remote loopback checks integrity of the local modem, the line and the remote modem. Figure 4. Remote Loopback Note: For FOM-4SF with E1 or T1 interface, if the AIS is enabled when a local or remote loopback is active, an AIS is sent to the remote DTE.

Simultaneous Loopbacks If both modems activate remote loopback, the first request sent is activated. For FOM-4SF with V.24, V.35, RS-530 and X.21 interfaces, the local loopbacks take priority over remote loopbacks requested from the remote modem. For FOM-4SF with E1 and T1 interfaces, the local modem can run a local loopback at the same time that the remote modem initiates a remote loopback (see Figure 5). Figure 5. Simultaneous Loopbacks (FOM-4SF with E1 or T1 Interfaces) To return to normal operation, set the test DIP switches to OFF, or lower the loopback activation pins of the DTE. The TST LED will turn off automatically.