Plant Client Contract Code Document ID Contract No. TECHNICAL SPECIFICATIONS DC SHUNT Rev 00 Page 1 of 2

Similar documents
50-SDMS-01 SPECIFICATIONS FOR

36kV VOLTAGE TRANSFORMERS (OUTDOOR TYPE)

THE KENYA POWER AND LIGHTING CO. LTD. SPECIFICATIONS for IMPULSE VOLTAGE TEST EQUIPMENT

COMBINED METERING TRANSFORMERS (OUT DOOR TYPE) FOR 11kV & 33kV SYSTEMS

TECHNICAL SPECIFICATIONS FOR BOLT HEATING EQUIPMENT

LOCOMOTIVE ENGINEERING DEPTT.

11-SDMS-03 REV. 02 SPECIFICATIONS FOR

ELECTRICAL NETWORKS SPECIFICATION TECHNICAL SPECIFICATION FOR A 230V/110V AND 400V/110V TRANSFORMER

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA MATERIALS MANAGEMENT / CAPITAL EQUIPMENT

012: 2015 CEB SPECIFICATION GALVANIZED STEEL WIRE (EXCEPT SHIELDING WIRE FOR TOWER LINE APPLICATION)

TECHNICAL SPECIFICATION FOR LEVEL CONTROL VALVE HANDLING WATER

TECHNICAL SPECIFICATION OF LT SHACKLE BOLT (G. I. BOLT) WITH NUT AND SPRING WASHER

The RSM shall be extensively used in field & laboratory for verification of the accuracy of all types of single-phase energy meters.

GENERAL TECHNICAL SPECIFICATION (Turnkey Work)

INDIAN INSTITUTE OF TECHNOLOGY KHARAGPUR , INDIA

SECTION - II BID DATA SHEET

TECHNICAL SPECIFICATION FOR 11KV, 3C x95mm mm 2 AERIAL BUNCHED CABLES FOR OVERHEAD LINES (CROSSED LINKED POLYTHENE DRY GAS CURED)

MESP TECHNICAL SPECIFICATION FOR AN ESSENTIAL SERVICES SUPPLY STEP UP TRANSFORMER

TECHNICAL SPECIFICATION

MGVCL/MM/ /2082/11KV AB CABLE TECHNICAL SPECIFICATION FOR 11KV AERIAL BUNCHED CABLES FOR OVERHEAD LINES

TECHNICAL SPECIFICATION FOR ANNUBAR (DELTA TUBE)

001: 2007 CEB STANDARD

To be completed by the Bidder. Sl.No. Parameters CPRI Specification / Requirements Qty

Maharashtra State Electricity Distribution Co. Ltd.

Single-Phase Mini Pad-Mounted Transformer Specification: Energy+ MPDL

SI.No Parameters CPRI Specification/Requirements To be Completed by the Bidder Guaranteed Technical

TENDER COVER PAGE (CHECK LIST)

DISTRIBUTION TRANSFORMER kv

079 : 2000 CEB STANDARD ALUMINIUM BINDING WIRE

TECHNICAL SPECIFICATIONS for 300KV CONSTANT POTENTIAL X RAY EQUIPMENT (for industrial applications) S. No. PARTICULARS BHEL SPECIFICATIONS


MANUFACTURING GUIDELINES FOR PLC (LEVEL-1 AUTOMATION)

NATIONAL POWER TRAINING INSTITUTE (WR) (Ministry of Power, Govt. of India) NAGPUR TENDER DOCUMENT SUPPLY OF DRAWING TABLES AND STOOLS

GENERAL TECHNICAL SPECIFICATION

Maharashtra State Electricity Distribution Co. Ltd.

PURCHASE DIVISION DEPARTMENT QUALITY MANUAL Revision No. : 02 Issue No: : 2 Dt of Revision : Issue Dt. :

Section Meetings Section Material and Equipment. None Required

PROCUREMENT OF SERVO CONTROLLED VOLTAGE STABILIZER FOR STPI-NASIK

2.14 Main Cable Type HO7RN-F4G10-15 Metres each Chiller Tank Capacity- 75 Litres Compressor- 3.5 Tons Refrigeration type

DISTRIBUTION TRANSFORMER 11 / kv

.2 Accompany all submissions with a transmittal letter, in duplicate, containing:.4 Specification Section number for each submittal

NATIONAL LAW UNIVERSITY DELHI SECTOR-14, DWARKA NEW DELHI

INTERPLANT STANDARD - STEEL INDUSTRY

SPECIFICATION FOR SAFETY POLE SIGNS & ACCESSORIES

STANDARD SPECIFICATION FOR COLD JUNCTION COMPENSATION BOXES (CJCB)

Certificate by the Architect: Certified that no addition and deletion has been made to the tender documents downloaded from the IIT Madras web site.

Technical Specification. for 1.1 KV Copper Control Cable

SPECIFICATION FOR AC-DC POWER SUPPLY FOR DEFENCE APPLICATION

TECHNICAL BID. T 4262 (E-Tender I.D. No. ) Subject: Supply of HT & SS fasteners, circlip & cotter pins for BMD-6 Ukai GSECL TPS. EMD D. D. No.

TECHNICAL SPECIFICATION FOR BOUGHT OUT ITEM FOR ESP : M/S NATIONAL THERMAL POWER CORPORATION LTD (NTPC) ISSUED BY EDC - ECI

Title Substation Auxiliary Transformer from Rectifier Transformer Secondary. Reference Number PDS 01 (RIC Standard: EP SP)

REVISION #1. Section. fire alarm B. C. the hot. intent of. required. manufacturer. materials. C. Warranty

Fabrication and Supply of Cable Tray. CTI Agartala, Aligarh, Gorakhpur, Muzaffarpur, Patna

DATA SHEET FOR LIGHTING TRANSFORMER APPD. BY VDV PROJECT NO

VOLUME - 4 (GENERAL TECHNICAL SPECIFICATIONS)

conductor Extruded Cross - Linked Polyethylene Insulated (XLPE) Power Cable Rated Voltage U 0 /U = 12/20 kv U 0 /U = 18/30 kv

Tender Management System Version 1.0 [ Tender Document ]

NPS/002/016 Technical Specification for 33 kv Cable Joints and Terminations

VI 3 - i TABLE OF CONTENTS

Safety Manual. Omni-ID UHF Tags

MESP TECHNICAL SPECIFICATION FOR AN AUXILIARY OR ESSENTIAL SERVICES AND AUXILIARY TRANSFORMER FOR USE IN A RAILWAY SUBSTATION

SECTION PANELBOARDS

DEPARTMENT OF ARCHITECTURE

NOTICE INVITING TENDER Limited Tender on Single Bid Basis Milling Cutters. Tender Enquiry No: Due Date:

Technical Specifications for Portable 3-Ø Power Analyzer

CUSTOMER SUPPLIED HIGH VOLTAGE METERING UNIT SPECIFICATION FOR 11, 22 & 33 kv

1.0 mh, 3150 A LINE TRAP

POTENTIAL TRANSFORMER

ADDENDUM 1 and 2 September 29, 2017 Request for Proposals: Wi-Fi and Wireless Backhaul Replacement

ELECTRICAL WORKS PART 1 - GENERAL 1.01 SCOPE OF WORK

Annexure - V. Specifications, Typical Drawing & Data Sheet for Split TEE (Hot Tapping Material)

GSM-R Terminal filter Technical Specification

Technical Specifications SECTION C

Tender NO. PGVCL/PROC/Cable & Pipeline Locator/832

TECHNICAL SPECIFICATION FOR 22 KV CURRENT TRANSFORMERS

PROCEDURE FOR INSPECTION OF ELECTRICAL INSTALLATIONS ABOVE 250KVA

TECHNICAL SPECIFICATION OF ELECTRICAL MATERIALS CT & PT GROUP C

Technical recommendation for the purchase of Real Time Thermal Rating for transformers

CAPACITOR VOLTAGE TRANSFORMER

Installation & Operating Manual. iwap202

00-General Drawings. Doc. no.: NA-00-STS002

energy management systems Shunts

Ref No : PUR/GT/IMP/VELC-ADITYA/20/ September 19, 2016.

Motor-protective circuit-breaker, 3p, Ir=40-50A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

LIGHTNING ARRESTOR. September 2017 WEST BENGAL STATE ELECTRICITY TRANSMISSION COMPANY LIMITED

BUREAU OF INDIAN STANDARDS. Draft Indian Standard TWO COMPONENTS HIGH BUILD EPOXY MICACIOUS IRON OXIDE (MIO) PIGMENTED INTERMEDIATE COAT SPECIFICATION

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TECHNICAL SPECIFICATION OF STAY WIRE FOR TRANSMISSION LINES AND SUB STATIONS

SEPARATOR P20G TYPE USER S MANUAL

(TECHNICAL SPECIFICATIONS & GTP FORMATS) 11KV METERING UNITS

MEDIUM VOLTAGE PRODUCT. KOKM Cable current instrument transformers Instruction for Installation, use and maintenance

071-3: 2009 CEB SPECIFICATION

January, 2014 Page 1 of 5

INTERNATIONAL STANDARD

PURCHASE SPECIFICATIONS 500KVA DRY TYPE TRANSFORMER FOR OIL RIG APPLICATIONS

INTER PLANT STANDARD STEEL INDUSTRY VARIABLE VOLTAGE VARIABLE FREQUENCY SYSTEM (V.V.V.F.) V/F, VECTOR CONTROL / TORQUE CONTROL

TECHNICAL SPECIFICATION OF PORTABLE ELECTRONIC REFERENCE STANDARD ENERGY METER (ERS METER) FOR T E S T I N G O F HT THREE PHASE ENERGY METERS:-

Organisation Internationale de Métrologie Légale

TECHNICAL SPECIFICATIONS

ADDENDUM NO. 2 PROJECT: COURTLAND PUMP STATION CONTRACT: IFB NO COM.00030

Transcription:

TECHNICAL SPECIFICATIONS Rev 00 Page 1 of 2 0 IFI Release for Enquiry 14/12/18 SSS 14/12/18 HGG 14/12/18 RBU - Rev. Status Description Date Prepared Date Checked Date Approved AC Based on: PIN-QMC-03-F101 03-2015 Copyright 2015 : All rights reserved ThyssenKrupp Industrial Solutions (India) Private Limited Barcode Category Code: - 05

CAUSTIC SODA Punjab Alkali PACL 0215-ELT-000-EC-0021 --- TECHNICAL SPECIFICATIONS Rev 00 Page 2 of 2 INDEX SHEET The document Cover Sheet indicates revisions made in this document along with the purpose of issue of the revised document. The details of revisions made in the enclosures of this document are listed in the table of Contents below and the enclosures listed therein are an integral part of this document. CONTENTS Part Docu Size Description No. Of Pages Rev. No. Revised Clauses A4 Index sheet and status of revision 2 0 - A4 Site Conditions 1 0 - Part-I A4 Technical specification for DC shunt 2 0 - Part-IIA A4 Notes on Method of Offer Submission 1 0 - Part-IIB A4 Scope of Supply & Price Schedule 1 0 - Part-III A4 Drawings & documents enclosed 1 0 - Part-IV A4 Compliance Declaration 2 0 - PIN-QMC-03-F101 03-2015

TECHNICAL SPECIFICATION POLARISATION RECTIFIER Rev 00 Page 1 of 1 Sr. Description Site Condition No. 1. Location Naya Nangal, Punjab 2. Altitude 346 meters above MSL 3. Ambient Temperature - Maximum 48 Deg C 4. Ambient Temperature Minimum 4 Deg C 5. Design Ambient Temperature (For Electrical Equipment) 50 Deg C 6. Max. Relative Air Humidity 95 % at 50 Deg C 7. Rainfall (Max.) 50 mm per hour 8. Seismic Zone Zone-IV as per Part-4 of IS-1893 9. Soil Resistivity ** Ohm-meter 10. Thermal Resistivity of soil ** Deg. K.m/watt 11. Presence of Corrosive atmosphere Yes, Highly Corrosive, laden with traces of sulphur di/tri-oxide. Abrasive dust and coal particles (5-100 microns) with traces of Cl 2 12. Tropicalizing required Yes ** : Data to be provided later by tkis-india PIN-LEP ELT-1001-F01 Rev.0, 12-2015

Part-I - General Specifications Rev 00 Page 1 of 2 1.0 SCOPE This specification covers the design, manufacturing, testing at factory of DC shunt for DC current measurement of a electrolyser system. DC shunt shall comply with all currently applicable Standards specified in this specification. Where conflict arises between the various parts of this specification and standards, the stringent one shall prevail. 2.0 GENERAL 2.1 The system shall be designed and rated according to the standards, site conditions and data specified. 2.2 The latest editions of the standards shall apply. 2.3 All devices required for the proper functioning shall be included in the scope of supply even if they are not specifically indicated herein. 2.4 The shunt will be installed indoor, in line with the Existing DC busbars from the electrolysers. 3.0 TECHNICAL PARTICULARS 3.1 Type & Standard : Open type confirming to IEC 60051/ DIN / VDE R IS 1248-8 The standards shall be suitably applied for the rating mentioned below) 3.2 Make : * 3.3 Location : Indoor 3.4 Installation & Connection : Shunt shall be installed without any external support, directly on the main busbars by bolted connection for incoming & outgoing. 3.5 Arrangement : Horizontal shall be preferred for existing bus bar 3.6 Material of connection : Copper 3.7 Contact surface Plainness : Plainness of contact surface area ± 0.1mm. 3.8 Output Terminals : 2 nos. terminals shall be provided with copper lugs suitable for termination of 2.5 mm 2 copper cable for carrying the voltage (60mV) signal. 3.9 Rated current : 24000 A DC 3.10 Quantity : 6 nos. As per part-iib 3.11 Voltage drop at rated current : 60 mv 3.12 Accuracy class at rated current : 0.5 % 3.13 Permissible continuous : Overload ka / % * 3.14 Temperature at rated load : 0 C * 3.15 Dimensions : mm (Length) x mm (Width) x mm (Height) * 3.16 Weight : kgs * 3.17 Language : All inscriptions, lettering and instruction shall be English

Part-I - General Specifications Rev 00 Page 2 of 2 Notes : 1. Vendor to furnish data for items marked as ' *'. 2. Vendor shall submit the original catalogue of DC Shunt indicating details such as all dimensions, front view, side view, hole details for copper flexible connection, terminal arrangements for external cable connection etc. 3. Following document shall be submitted either for client review /approval. a)physical dimension, holes checking with compliance certificate. b) Copper material test certificate for review. c) Temperature rise calculation or test certificate at rated current at site ambient temperature. d) Calibration test shall be conducted at reputed institute or at vendor works at Minimum 5000A DC current on all the DC shunts 4. Vendor shall submit 6 copies of test certificates.

Plant Client Contract Code Document Number Contract No. Part-IIA Notes on Method of Offer Submission Rev 00 Page 1 of 1 1. Offer shall be submitted in two parts viz. Technical part and Price part. 2. Technical part shall consist of following: a. Copy of General Specifications of this specification with acceptance of all clauses to be indicated by letter 'A on right side of the specification sheet with seal of the company and initial of authorised person. Deviations, if any, should be indicated by letter D. b. Copy of Design Data Sheet of this specification duly filled in clearly and legibly in the assigned space against items marked thus ' ', along with all documents requested with the offer. c. Copy of Scope of Supply & Schedule of Prices of this specification marked quoted against each item, to confirm that the vendor is making an offer as per break up requested therein. d. Please refer Part-I with list of testing document to be submitted by vendor. e. Covering letter enclosing above document. f. Filled up Compliance Declaration of this specification with seal of the company and initial of the authorized person. 3. Price part shall consist of following: a. Copy of Scope of Supply & Schedule of Prices of this specification with unit rate of each item and total price of each section, with total price of the tender, including supplies and various services as specified or as recommended by the vendor. b. Covering letter enclosing above price part and deviation on commercial terms if any. 4. Both the parts of offer shall be submitted in separate sealed envelope indicating details of offer such as Technical or Price part, enquiry no. and date of submission. 5. Offer will be evaluated based on above documents only and any other document enclosed with the offer shall not be considered for evaluation of offer.

Plant Client Contract Code Document Number Contract No. Part-IIB - Scope of Supply & Schedule of Prices Rev 00 Page 1 of 1 EQUIPMENT & SERVICES TO BE FURNISHED UNDER THIS SPECIFICATION Sr. No. Description Quantity Unit Rate Total 1. Following DC Shunt complete with all accessories in accordance with this specifications Part-I. Rated system Voltage 425 V DC A) 425 V, 24000 A DC, 60 mv 6 Nos. 2. TESTING & INSPECTION Tests as specified in relevant standard shall be performed in presence of purchaser s representative, if so desired by the purchaser. Extra cost for any of the tests shall be quoted indicating the tests reference item no. and description as per Part-II of this specification. i. Routine tests Test Certificate to be Furnished ii. Type tests Not Applicable iii Refer Part-I Notes for Test required on material & calibration of DC shunt. Test Certificate to be TOTAL PRICE OF THIS TENDER INCLUDING ALL ABOVE ITEMS. ncluded in item 1 Not Applicable Included in item 1 Not Applicable

Plant Client Contract Code Document Number Contract No. Part-III - Drawings & Documents Enclosed Rev 00 Page 1 of 1 Following drawing(s)/document(s) is/are enclosed: Drawing no. Description 1 0215-ELT-11-EC-0021A Dimensional drawing for DC Shunt Indeginous( Indian make)

Part-IV - Compliance Declaration Rev 00 Page 1 of 2 Compliance Declaration Please note that vendor shall indicate his replies to the following points without which the offer shall be liable for rejection. Deviations if any from this specification shall be listed in the enclosed format (List of Deviations) indicating the applicable specification clause. The vendor will be made liable for full compliance with the specification requirements, if deviations are not listed in List of Deviations as it will be deemed as No deviation. S.NO DESCRIPTION EXPECTED REPLY 1. Confirm that all deviations against No Deviation this specifications are consolidated under List of Deviations. Deviations mentioned elsewhere will not be taken into consideration. 2. Confirm that there is no discrepancy No in the technical details outlined in the Discrepancy specification and the technical bid data. 3. Relevant Catalogues/ literature giving Yes specifications for all models offered including sizing data is enclosed with the offer. 4. Relevant Catalogues/ specifications of Yes all bought out items are enclosed with the offer. 5. Quoted for Spare parts Quoted recommended for 2 years continuous trouble-free operation along with listing 6. Quoted and offered recommended Quoted Commissioning spares along with listing 7. Quoted for Mandatory spares Quoted CONFIRMATION BY VENDOR REMARKS (Signature of Vendor) Name: Designation : Date : (Company Seal)

Part-IV - Compliance Declaration Rev 00 Page 2 of 2 LIST OF DEVIATIONS Doc. No: Sr. Clause Page No Subject / Deviation No. No Description (Signature of Vendor) Name: Designation : Date : (Company Seal)