Features Regulated Converter Unique, patent-pending design Isolated power supply with integrated mains filter Packaged inside of line filter case Safe, touchable DC outputs Easy installation Worldwide standard IEC input VAC universal input voltage Description The RAC5-K/C14 is a unique design that combines a mains filter and isolated power supply in the same case as a mains input filter alone, at a cost lower than many mains filters. It fits into a standard IEC kettle connector mounting hole, so installation time is only a few seconds. The touchable output spade terminals are safe extra-low voltage (SELV) available in 3.3V, 5V, 12V, 15V and 24V DC output voltages and are protected against short circuits, overload and overvoltage. The metal case offers secure fixing and enhances thermal dissipation allowing an operating temperature from - C to + C. The RAC5-K/C14 is ideal for powering single board computers such as the Raspberry Pi (including touchscreen), Arduino, BBC Micro:bit, etc. AC/DC Converter RAC RAC5-K/C14 5 Watt Single Output Selection Guide Part Number RAC5-3.3SK/C14 RAC5-5SK/C14 RAC5-12SK/C14 RAC5-15SK/C14 RAC5-24SK/C14 Input Voltage Range [VAC] Output Voltage [VDC] 3.3 5 12 15 24 Output Current [ma] 151 42 333 21 Efficiency typ (1) [%] 76 81 81 84 Max. Capacitive Load (2) [µf] 1 3 Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient Note2: Max Cap Load is tested at nominal input and full resisitive load E224736 UL/IEC/EN62368-1 pending IEC9-1 pending FCC Part 15 certified ANSI C63.4 certified IEC/EN6124-3 compliant EN532 compliant EN524 compliant CB Report Model Numbering RAC5- SK/C14 nom. Output Power Output Voltage www.recom-power.com C14 input plug (male) Single REV.: /218 PA-1
BASIC CHARACTERISTICS RAC5-K/C14 Parameter Condition Min. Typ. Max. Internal Input Filter Input Voltage Range (3,4) nom. Vin= 85VAC 12VDC Input Current Inrush Current cold start at 25 C No Load Power Consumption ErP Standby Mode Conformity (Output Load Capability) Input Power= Input Frequency Range AC Input 47Hz 63Hz.5W 1.W 2.W Minimum Load % Power Factor Start-up Time Rise Time Hold-up Time Internal Operating Frequency Output Ripple and Noise 2MHz BW 3.3Vout, 5Vout others.6.45 75mW 2ms 12ms ms mvp-p 264VAC 3VDC 2mA ma 15A A.3W.7W 1.5W 8ms 1kHz 1% of Vout Pi type Notes: Note3: Note4: The products were submitted for safety files at AC-Input operation Refer to line derating graph on page PA-4 Efficiency vs. Load 2 1 RAC5-3.3SK/C14 3.3Vout 1 2 2 1 RAC5-5SK/C14 5Vout 1 2 continued on next page www.recom-power.com REV.: /218 PA-2
RAC5-K/C14 Efficiency vs. Load RAC5-12SK/C14 RAC5-15SK/C14 2 1 12Vout 1 2 2 1 15Vout 1 2 RAC5-24SK/C14 2 1 24Vout 1 2 REGULATIONS Parameter Condition Value Output Accuracy ±2.% typ. Line Regulation low line to high line, full load ±.5% typ. Load Regulation 1% to % load ±1.% typ. Transient Response 25% load step change recovery time 4.% max. µs typ. www.recom-power.com REV.: /218 PA-3
PROTECTIONS RAC5-K/C14 Parameter Type Value Input Fuse (5) internal T1A, slow blow Short Circuit Protection (SCP) below mw Hiccup, automatic restart Over Voltage Protection (OVP) Over Voltage Category Over Current Protection (OCP) Class of Equipment 125% - 195%, Latch-off OVCII 125% - 195%, Hiccup auto recovery Isolation Voltage (6) I/P to O/P; I/P to Case (GND) rated for 1 minute 3kVAC Isolation Resistance Isolation Capacitance Insulation Grade Leakage Current Notes: Note5: Refer to local safety regulations if input over-current protection is also required Note6: For repeat Hi-Pot testing, reduce the time and/or the test voltage Class I 1GΩ min. pf max. reinforced.25ma max. ENVIRONMENTAL Parameter Condition Value Operating Temperature Range Maximum Case Temperature Temperature Coefficient Operating Altitude @ natural convection.1m/s full load refer to derating graph -25 C to + C -25 C to + C + C ±.5%/K Operating Humidity non-condensing % - % RH max. Pollution Degree Vibration MTBF Design Lifetime according to MIL-HDBK-217F, G.B. m PD2 1-Hz, 2G 1min./ 1 cycle, period o min. each along X,Y and Z axes +25 C + C 4 x 1 3 hours 2 x 1 3 hours 136 x 1 3 hours Derating Graph (@ Chamber and natural convection.1m/s) Line Derating 2 1-25 -1 1 2 Ambient Temperature [ C] 2 1 85 264 Input Voltage [VAC] www.recom-power.com REV.: /218 PA-4
SAFETY AND CERTIFICATIONS RAC5-K/C14 Certificate Type (Safety) Report / File Number Standard Audio/video, information and communication technology equipment - Safety requirements (CB) IEC62368-1:214 2nd Edition Audio/video, information and communication technology equipment - Safety requirements (LVD) EN62368-1:214 + A11:217 Audio/video, information and communication technology equipment - Safety requirements pending UL62368-1, 2nd Edition, 214 CAN/CSA-C22.2 No. 62368-1-14, 2nd Ed. Information Technology Equipment, General Requirements for Safety (CB) RoHS2 IEC9-1 RoHS 211/65/EU + AM215/863 EMC Compliance Condition Standard / Criterion Low-voltage power supplies DC output - Part 3: Electromagnetic compatibility Electromagnetic compatibility of multimedia equipment - Emission requirements Information technology equipment - Immunity characteristics - Limits and methods of measurement Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 2: Immunity Limitations on the amount of electromagnetic intererence allowed from digital and electronic devices ESD Electrostatic Discharge Immunity Test Radiated, Radio-Frequency, Electromagnetic Field Immunity Test Fast Transient and Burst Immunity Surge Immunity Air: ±8,4,2kV Conatact: ±4, 2kV 1V/m, MHz-1GHz 3V/m, 1.4GHz-2GHz 1V/m, 2GHz-2.7GHz AC In Port: ±2kV DC out Port: ±2kV AC In Port (L-N): ±1kV DC Output Port: ±.5kV EN IEC6124-3:218 EN532:215, Class B EN524:21 + A1:215 EN514-2:215 FCC 47 CFR Part15, Supbart B EN-4-2 :29, Criteria B EN-4-3:26 +A1:28, Cirteria A EN-4-4:212, Criteria B EN-4-5:214+A1:217, Criteria B Immunity to Conducted Disturbances, Induced by Radio-Frequency Fields AC+DC Power Port: 1V EN-4-6:214, Criteria A Power Magnetic Field Immunity Hz, A/m EN-4-8:21, Criteria A Voltage Dips and Interuptions Voltage Fluctuations and Flicker in Public Low-Voltage Systems <=16A per phase Voltage Dips 2% Voltage Dips % Voltage Dips % Voltage Dips % Voltage Interruptions > 95% EN-4-11:24+A1:217, Criteria C EN-4-11:24+A1:217, Criteria C EN-4-11:24+A1:217, Criteria C EN-4-11:24+A1:217, Criteria B EN-4-11:24+A1:217, Criteria C EN-3-3:213 DIMENSION AND PHYSICAL CHARACTERISTICS Parameter Type Value Material Dimension (LxWxH) Weight case inner case potting nickel-plated steel plastic (UL94 V-) silicone rubber (UL96V-) 67. x 48. x 23.mm 56g typ. continued on next page www.recom-power.com REV.: /218 PA-5
RAC5-K/C14 Dimension Drawing (mm) 26.8 1 2 3 <67. 19.5 23. 48. 6.3 5. 2. 1. 21.5 7.6 53.4 3. Pinning information Pin # Single 1 VAC in (L) 2 Earth 3 VAC in (N) 4 +Vout 5 Earth 6 -Vout FC= fixing centers Tolerance: xx.x= ±.5mm xx.xx= ±.25mm 28.5 Ø3. R7 6 5 4 21. Mounting hole dimensions R4.1 Ø3.6-29.5 ±.5 FC. 22. ±.5. ±.1 PACKAGING INFORMATION Parameter Type Value Packaging Dimension (LxWxH) cardboard box 166. x 123. x 91.mm Packaging Quantity 1pcs Storage Temperature Range - C to +85 C Storage Humidity non-condensing 95% RH max. The product information and specifications may be subject to changes even without prior written notice.the product has been designed for various applications; its suitability lies in the responsibility of each customer. The products are not authorized for use in safety-critical applications without RECOM s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications. www.recom-power.com REV.: /218 PA-6