484 FREEDOM RING RD PROJECT DATA GENERAL PROJECT NOTES: LOCATION:. DIMENSIONS ARE TO FACE OF STUD OR TO COLUMN CENTERLINE UNLESS NOTED OTHERWISE. VERIFY ALL EXISTING CONDITIONS AND ADJUST WALL DIMENSIONS ACCORDINGLY. CONTACT ARCHITECT WITH ANY DISCREPANCIES.. CONTRACTOR SHALL NOTIFY ARCHITECT IMMEDIATELY UPON DISCOVERING ANY DISCREPANCIES OR CONFLICTING INFORMATION IN THESE DOCUMENTS. CONTRACTOR SHALL CAREFULLY REVIEW AND COMPARE ALL DRAWINGS DURING THE BIDDING PERIOD AND BEFORE INSTALLATION OF THEIR WORK. ANY INCONSISTENCIES IN THE DRAWINGS SHALL BE REPORTED PROMPTLY TO THE ARCHITECT AND ENGINEER(S) FOR CLARIFICATION.. DO NOT SCALE DRAWINGS. THE DRAWINGS ARE NOT NECESSARILY TO SCALE - USE GIVEN DIMENSIONS. DIMENSIONS TAKE PRECEDENCE OVER SCALE. CONTRACTOR TO VERIFY ALL DIMENSIONS IN FIELD. PROJECT DESCRIPTION: NEW SINGLE STORY BUILDING 4. CONTRACTOR SHALL NOTIFY ARCHITECT AND OWNER IMMEDIATELY UPON DISCOVERING ANY UNANTICIPATED EXISTING SITE CONDITIONS AFFECTING THE EXECUTION OF THESE DOCUMENTS (SUCH AS HAZARDOUS MATERIALS, ETC.). OCCUPANCY: PRIMARY : E (DAY CARE FACILITY) CONSTRUCTION TYPE: TYPE IIB NON-COMBUSTIBLE 5. CONTRACTOR SHALL ABIDE BY ALL LOCAL, STATE AND FEDERAL CODES AND REGULATIONS GOVERNING THIS PROJECT. ALLOWABLE AREA & HEIGHT: UNLIMITED AREA (IBC 507.) HEIGHT (IBC TABLE 706.4) = () STORIES 55 FEET ADD () STORY PLUS 0 FEET FOR SPRINKLERED 6. JOB SITE SHALL BE BROOM SWEPT AND CLEAN AT THE END OF EACH DAY. ALL DEBRIS SHALL BE PICKED UP AND DISPOSED OF PROPERLY INTO APPROVED CONTAINER. AREA/ NUMBER OF OCCUPANTS: EDUCATION: st FLOOR = 0,47 SF @ 50 GROSS (EXERCISE ROOM) = 08 OCC MEZZ FLOOR =,5 SF @ 0 GROSS (CLASSROOM) = 6 OCC TOTAL OCC = LIMITED TO 50 OCC PLUMBING: REQUIRED: MEN @ /50 WOMEN @/50 TOTAL REQUIRED TOTAL PROVIDED WC/ URINAL = WC = WC = 4 WC = 8 LAV = LAV = LAV = LAV = 4 GENERAL A0. COVER SHEET 04/8/08 CIVIL C. C. C. C.4 04/8/08 04/8/08 04/8/08 04/8/08 CIVIL - LANDSCAPE C.5 LANDSCAPE PLAN 04/8/08 ARCHITECTURAL PC. PLAN PC. PLAN PC. ROOF PLAN PC. EXTERIOR ELEVATIONS PC. EXTERIOR ELEVATIONS PC. D ELEVATIONS PC4. BUILDING SECTIONS 04/8/08 04/8/08 04/8/08 04/8/08 04/8/08 04/8/08 04/8/08 EXISTING CONDITIONS SITE PLAN GRADING PLAN UTILITY PLAN BUILDING PERSPECTIVE PROJECT LOCATION SITE LOCATION 7. MAINTAIN DESIGNATED EGRESS ROUTES DURING CONSTRUCTION BY KEEPING CLEAR OF CONSTRUCTION DEBRIS AND CLEARLY MARKING THE PATH OF EGRESS TRAVEL. 8. ALL MECHANICAL (HVAC), ELECTRICAL, AND PLUMBING ("MEP") DESIGN AND CONSTRUCTION TO BE BY A DESIGN-BUILD DELIVERY METHOD AND ARE SUBSEQUENTLY NOT PART OF THESE DOCUMENTS. IT IS THE MEP CONTRACTOR'S RESPONSIBILITY TO COORDINATE WITH THE GENERAL CONTRACTOR AND WITH THESE DRAWINGS THE FINAL DESIGN, RETROFIT AND INSTALLATION OF THESE SYSTEMS. NOTIFY THE ARCHITECT PRIOR TO MAKING ANY REVISIONS TO THE STRUCTURE OR ARCHITECTURAL FEATURES. 9. ELECTRICIAN TO VERIFY NEW LIGHT FIXTURE LAYOUT AND SUBMIT LIGHTING ENERGY CALC'S AS REQUIRED PER CODE. REVIEW PLAN AND LIGHTING FIXTURE SELECTION WITH ARCHITECT. FIRE CONTROL: FULLY SPRINKLERED BLDG: NFPA- SPRINKLER 0. HVAC CONTRACTOR SHALL SUBMIT PROPER DESIGN DRAWINGS AS NEEDED FOR PLAN APPROVAL AND BUILDING PERMITS. SEPARATION: NONE REQUIRED: ACCESSORY OCCUPANCY. ENSURE A CLEAR PATHWAY TO ALL EXISTS IS MAINTAINED AND SUSTAINED. EXIT TRAVEL DISTANCE: FULLY-SPRINKLERED BLDG: 50 FT MAX TRAVEL (TABLE 06.) 75 FT COMMON PATH OF TRAVEL (04.). WITHIN THIS DOCUMENT "NORTH, SOUTH, EAST, WEST" ARE REFERRED TO AS PROJECT NORTH AND MAY NOT BE TRUE NORTH EXITS:. ALL EXPOSED WOOD, OR IN CONTACT WITH CONC, OR MASONRY, SHALL BE PRESSURE TREATED () EXITS FROM REQUIRED () EXITS FROM FLOOR REQUIRED 4. VERIFY ALL ROUGH OPENINGS WITH RESPECTIVE MFG ACCESSIBILITY: ALL FLOORS SHALL BE ACCESSIBLE IF GREATER THAN,000 SF ELEVATOR REQUIRED AT FLOORS >,000 SF (NONE REQUIRED) FOLLOW ANSI 7. 00 5. PROVIDE SOUND BATT INSULATION AT ALL WALLS UNO 6. PROVIDE MOISTURE RESISTANT GWB AT ALL PLUMBING WALLS 484 FREEDOM RING RD BUILDING CODE: TWIN OAKS NEIGHBORHOOD ASSOCIATION CITY OF MADISON ZONING ORDINANCES DANE COUNTY ZONING ORDINANCES WISCONSIN ADMINISTRATIVE CODE 009 INTERNATIONAL BUILDING CODE ACCESSIBILITY ANSI A7. - 00 REVISIONS MARK DATE REGULATING MUNICIPALITIES: CITY OF MADISON DANE COUNTY STATE OF WISCONSIN SHEET NAME 484 FREEDOM RING RD SHEET INDEX SHEET NUMBER 7. PROVIDE GFI OUTLETS NEAR WATER SOURCES AND AS REQUIRED BY CODE 9. PROVIDE X BLOCKING AT ALL GRAB BAR LOCATIONS IN ALL UNITS PER ANSI A7. 009 0. FIELD VERIFY ALL CABINET LAYOUTS AND COORDINATE DIMENSIONS WITH SELECTED APPLIANCES AND FIXTURES, PROVIDE END PANELS AT ALL EXPOSED CABINET ENDS BUILDING LOCATION 484 FREEDOM RING RD. PROVIDE FIRE BLOCKING THROUGHOUT ENTIRE BUILDING PER IBC 77.. INTERIOR UNIT WALLS TO BE TYPE S4A-B UNO 4/8/08 0:4:50 AM O:\projects\Bisbee\Spartan Day Camp\Drawings\Revit\Spartan.rvt COVER SHEET. SUBMIT ALL FIXTURES, APPLIANCES, MATERIALS, SHOP DRAWINGS, PLAN MODIFICATIONS TO THE ARCHITECT FOR REVIEW AND APPROVAL Project Status 04/8/08 PROJECT CONTACTS: OWNER: SPARTAN DAY CARE 475 DALE CURTAIN DR MCFARLAND, WI 5558 ARCHITECT: SKETCHWORKS ARCHITECTURE, LLC 7780 ELMWOOD AVE., STE 08 MIDDLETON, WI 556 GENERAL CONTRACTOR: NAME ADDRESS CITY, ST ZIP CONTACT: MEGAN BISBEE 608-48-00 CONTACT: NAME (ARCHITECT) NAME (DESIGNER) 608-86-7570 CONTACT: NAME PHONE STRUCTURAL ENGINEER: MP-SQUARED STRUCTURAL ENGINEERS, LLC 58 D'ONOFRIO DR STE 0 579 CONTACT: MARK PUCCIO 608-8-4770 CIVIL ENGINEER: QUAM ENGINEERING, LLC 4604 SIGGELKOW RD MCFARLAND, WI 5558 CONTACT: AARON FALKOSKY 608-88-7750 PRELIMINARY A0.
PC. A. 4 5 6 0'-0" 4'-0" '-0" '-0" 4'-0" 4'-0" 4'-0" A B PC. A. C 84'-0" '-0" '-0" '-4" 9'-0" '-4" 9'-9 7/8" OPEN GYM 0 9'-0" '-4" '-6" PC. A. '-4" 484 FREEDOM RING RD D E '-0" '-0" '-7 7/8" 0'-0" 8'- /" 5'-0 /" 4'- /" 4'- /" 0'-" RECEPTION 00 WOMEN'S ROOM 0 MEN'S ROOM 09 KITCHEN 07 STORAGE 0 OFFICE OFFICE 06 05 7'-0" PLAN 5'-4 /" 4'- /" 9'-0 7/8" '-4" 9'-0" '-4" 0'-0" '-4" 4'- /" 4'- /" 4'- /" 4'- /" '-4" 9'-" '-6 /8" 4'- /" 4'-0 /" 4 PC. A. 4'- /" 4'- /" 9'-0" '-4" 4'- /" 9'-0" 4'- /" 04/8/08 0' 4' 8' 6' ' PLAN /6" NORTH NORTH /6" = '-0" PLAN TRUE PRELIMINARY PC.
PC. A. 4 5 6 A B PC. A. C OPEN BELOW PC. A. 484 FREEDOM RING RD 9'- /4" 99'-6 /4" D E 9'-4 /" DN 00 DN PLAN 4 PC. A. 04/8/08 0' 4' 8' 6' ' PLAN /6" NORTH /6" = '-0" PLAN NORTH TRUE PRELIMINARY PC.
PC. A. A B PC. A. C 84'-0" 4 5 6 0'-0" TON RTU PC. A. 484 FREEDOM RING RD D ROOF PLAN E 4 PC. A. 0' 4' 8' 6' ' ROOF PLAN /6" NORTH /6" = '-0" PLAN NORTH TRUE PRELIMINARY 04/8/08 PC.
MATERIAL CALLOUT 5 A 6 WEST ELEVATION /6" /6" = '-0" B C D E 4 0'-0" 7'-0" 7 '-0" 00'-0" # Comment METAL PANEL "PANEL RIB" OR EQUIV, COLOR: TAN, ORIENTATION: VERTICAL METAL PANEL "PANEL RIB" OR EQUIV, COLOR: BROWN, ORIENTATION: VERTICAL METAL PANEL "BOX RIB" OR EQUIV, COLOR: BLUE, ORIENTATION: HORIZONTAL 4 METAL PANEL "BOX RIB" OR EQUIV, COLOR: GREEN, ORIENTATION: HORIZONTAL 5 PREFINISHED ALUMIN, COLOR: BROWN 6 LOW-E ALUMN STOREFRONT WINDOWS, COLOR: BROWN 7 STEEL CANOPY W/ "C" CHANNEL, COLOR: BROWN 8 HOLLOW METAL DOOR, COLOR: BROWN 9 GLASS SECTIONAL OVERHEAD DOOR METAL PANEL TAN: "PANEL RIB" OR VERTICAL 484 FREEDOM RING RD 5 6 5 4 0'-0" 7'-0" '-0" METAL PANEL BROWN: "PANEL RIB" OR VERTICAL METAL PANEL BLUE: "BOX RIB" OR HORIZONTAL EXTERIOR ELEVATIONS 9 8 00'-0" METAL PANEL GREEN: "BOX RIB" OR HORIZONTAL 04/8/08 NORTH ELEVATION /6" /6" = '-0" PRELIMINARY PC.
5 E D EAST ELEVATION /6" /6" = '-0" 6 C B A 0'-0" 7'-0" '-0" 00'-0" MATERIAL CALLOUT # Comment METAL PANEL "PANEL RIB" OR EQUIV, COLOR: TAN, ORIENTATION: VERTICAL METAL PANEL "PANEL RIB" OR EQUIV, COLOR: BROWN, ORIENTATION: VERTICAL METAL PANEL "BOX RIB" OR EQUIV, COLOR: BLUE, ORIENTATION: HORIZONTAL 4 METAL PANEL "BOX RIB" OR EQUIV, COLOR: GREEN, ORIENTATION: HORIZONTAL 5 PREFINISHED ALUMIN, COLOR: BROWN 6 LOW-E ALUMN STOREFRONT WINDOWS, COLOR: BROWN 7 STEEL CANOPY W/ "C" CHANNEL, COLOR: BROWN 8 HOLLOW METAL DOOR, COLOR: BROWN 9 GLASS SECTIONAL OVERHEAD DOOR METAL PANEL TAN: "PANEL RIB" OR VERTICAL 484 FREEDOM RING RD 5 7 4 5 6 6 4 0'-0" 7'-0" '-0" METAL PANEL BROWN: "PANEL RIB" OR VERTICAL METAL PANEL BLUE: "BOX RIB" OR HORIZONTAL EXTERIOR ELEVATIONS 00'-0" METAL PANEL GREEN: "BOX RIB" OR HORIZONTAL 04/8/08 SOUTH ELEVATION /6" /6" = '-0" PRELIMINARY PC.
ENTRY ENTRY AND BACK D ELEVATIONS 484 FREEDOM RING RD SIGGLEKOW AND FREEDOM RING Project Status 04/8/08 PRELIMINARY PC.
E PC4. D C TON RTU B PC4. A 4'-9" 5'-4" 0'-0" 7'-0" '-0" 00'-0" TO FOOTING 96'-0" BLDG CROSS SECT /8" NOT TO = '-0" SCALE TON RTU 4 5 6 PC4. 4'-9" 9'-7" 0'-0" 7'-0" '-0" 00'-0" TO FOOTING 96'-0" 484 FREEDOM RING RD BLDG LONG SECT @ MEZZ /8" NOT TO = '-0" SCALE 4 5 6 PC4. 0'-0" 7'-0" BUILDING SECTIONS '-0" Project Status 04/8/08 00'-0" TO FOOTING 96'-0" BLDG LONG SECT @ BACK WALL /8" NOT TO = '-0" SCALE PRELIMINARY PC4.