6ES BE30-0XB0 6ES AE30-0XB0 6ES HE30-0XB0

Similar documents
6ES7214-1AG31-0XB0. General information Engineering with. Supply voltage 24 V DC Yes permissible range, upper limit (DC)

SIMATIC S7-1200, CPU 1212C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 8 DI 24V DC; 6 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC

SIPLUS SM 1234 ANALOG INPUT/OUTPUT MODULE

Product type designation. General information. Hardware product version 01. Firmware version V2.6. Engineering with. update.

100 h; (min. 70 h at 40 C); 200 days (typ.) with optional battery module Memory Number of memory modules (optional)

CPU 221, CPU 222, CPU 224, CPU 224 XP, CPU 224 XPsi, CPU 226

Product type designation. General information. Supply voltage

6ES7314-6BH04-0AB0. STEP7 as of V5.5 + SP1 or STEP 7 V5.3 + SP2 or higher with HSP 204

General specifications and features

SM 1222 DIGITAL OUTPUT MODULE

CPU 314C-2 PTP. Function

General information. Supply voltage

SM 1223 DIGITAL INPUT/OUTPUT MODULE

2A (recommended) Power loss

Data sheet CPU 314ST/DPM (314-6CF02)

Data sheet CPU 313SC (313-5BF13)

Data sheet VIPA CPU 314SC DPM (314-6CG23)

Data sheet CPU 013C (013-CCF0R00)

Siemens AG ED CB00-0BA0 6ED HB00-0BA0 6ED MB00-0BA1 6ED FB00-0BA1 Supply voltages Rated value

FM COUNTER MODULE

PLC-K506 Series FEATURES DESCRIPTION FEATURES

KNC-PLC-K506 Series FEATURES DESCRIPTION FEATURES

FM HIGH-SPEED BOOLEAN PROCESSOR

FM 355 CONTROLLER MODULE

SIMATIC S7-300 Function modules

SIMATIC S5. ET 100U Distributed I/Os. Manual. EWA 4NEB a

"Modular" versions designed for application-specific functions LCD with 4 lines of 18 characters and configurable backlighting

02/11/2015

Custom "Compact" range with display CD20 Custom Part number

EXM INPUT/OUTPUT EXPANSION

02/11/2015

02/11/2015

02/11/2015

02/11/2015

FM COUNTER MODULE

Digital electronic module 4DO DC24V/2A HF (6ES7132-4BD30-0AB0) SIMATIC

SEN TRONIC AG. Millenium 3 Essential. Essential range: powerful but cost effective. Part numbers. Accessories

Overcurrent Protection / 7SJ45

XIOC technology and networking modules

FM COUNTER MODULE

AIO and DIO PFXLM4B01DAK:Sink Output Type PFXLM401DAC:Source Output Type Virtual Resolution (pixels)

PFXLM4B01 D * * (1) (2) (3) (4)

Primary switch mode power supplies Product group picture

S7-200 SMART Programmable controller Answers for industry.

em4 local - Robust Specific characteristics Part number

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

Analog signal converters CC-E I/I

QUINT-PS-24DC/24DC/10

Temperature Measurement

Electronic timer CT-TGD.22

Zentralbaugruppen CPU 222

Programming restrictions when operating SM 331; AI 8 x RTD with PROFIBUS masters which only support DPV0.

FM POSITIONING MODULE

SITRANS T measuring instruments for temperature

LINAX 4000L Continuous-line recorder

General information. CiR - Configuration in RUN

Temperature Transmitters - Head Mounted

TRIO-PS/1AC/24DC/ 5. Extract from the online catalog. Order No.:

em4 em4 alert em4 alert 2G

PFXLM4201T A D * * (1) (2) (3) (4) (5) (6)

WAGO Application: Plastic Technology Center (SKZ) in Würzburg, Germany

Power supply CP-E 24/2.5

SIPROTEC easy 7SJ46 Numerical Overcurrent Protection Relay

Power supply CP-D 24/4.2 Primary switch mode power supply

Temperature Transmitters - DIN Rail Mounted

Multifunctional counter tico 772/773/774

Type CP-S, CP-C & CP-A Switch mode

CM3-SP04EAO CM3-SP04EAA CM3-SP04EOAI CM3-SP04EOAV

POINTAX 6000L2 Point Recorder

High-Voltage Isolation Amplifiers / Shunt Isolators. VariTrans P 29000

Product type designation. General information. CiR - Configuration in RUN. Supply voltage. Input current

Advanced Ladder Logic Full IEC Languages 25A for <1 24 VDC DC Switched

Temperature Transmitter itemp RTD DIN rail TMT 127

Power supply CP-E 24/20.0

SITRANS T measuring instruments for temperature

CP-E range Benefits and advantages

CP-T range Product group picture

B850 Boiler House Energy Monitor

Power quality Harmonics up to 40th harmonic Rotary field components Distortion factor THD-U / THD-I

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

08/07/2015

This data sheet is only valid in association with the IL SYS INST UM E user manual.

Power supply CP-D 24/1.3

Temperature transmitter itemp RTD DIN rail TMT 127

UniStream Uni-I/O Modules

B850 Boiler House Energy Monitor

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

CAN-IO Custom IO remote module

S200 I/O System Units

FC Series Signal Conditioners

NI REM Remote I/O Overview DATASHEET. Temperature Input Module for Remote I/O

Switching power supplies CP range, Linear power supplies CP-L range. Content

DOBLE F6150e TECHNICAL SPECIFICATIONS

Power supply CP-D 12/2.1

Power supply CP-T 48/20.0 Primary switch mode power supply

Dimension diagrams All dimensions in mm. Typical connection UMG 604-PRO. Power Analyser UMG 604-PRO. Front view. Side view. Versorgungsspannung

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800)

Vibration 10 Times in X,Y,Z IEC In Case of Continuous Vibration

20 General technical data XI/ON

UniStream Built-in. Technical Specifications US7-B5-RA28, US7-B10-RA28 US7-B5-TA30, US7-B10-TA30

Transcription:

Overview The compact high-performance CPU With 2 integral input/outputs Expandable by: - 1 signal board (SB) or communication board (CB) - 8 signal modules (SM) - Max. 3 communication modules (CM) Technical specifications 6ES7 21-1BE30-0XB0 6ES7 21-1AE30-0XB0 6ES7 21-1HE30-0XB0 Product type designation AC/DC/Relay DC/DC/DC DC/DC/Relay Product version associated programming package STEP 7 V10.5 or higher STEP 7 V10.5 or higher STEP 7 V10.5 or higher Supply voltages Rated value 2 V DC Yes Yes permissible range, lower limit (DC) 20. V 20. V permissible range, upper limit (DC) 28.8 V 28.8 V 120 V AC Yes 230 V AC Yes permissible range, lower limit (AC) 85 V permissible range, upper limit (AC) 26 V permissible frequency range, 7 Hz lower limit permissible frequency range, 63 Hz upper limit Load voltage L+ Rated value (DC) 2 V 2 V 2 V permissible range, lower limit (DC) 5V 20. V 5V permissible range, upper limit (DC) 250 V 28.8 V 250 V Current consumption Current consumption (rated value) Current consumption, max. 100 ma at 120 V AC; 50 ma at 20 V AC 300 ma at 120 V AC; 150 ma at 20 V AC 500 ma; Typical 1.5 A; 2 V DC 1.2 A; 2 V DC Inrush current, max. 20 A; At 26 V 12 A; at 28.8 V DC 12 A; at 28.8 V DC Current output to backplane bus (DC 5 V), max. 1 600 ma; Max. 5 V DC for SM and CM 1 600 ma; Max. 5 V DC for SM and CM Power losses Power loss, typ. 1 W 12 W 12 W 1 600 ma; Max. 5 V DC for SM and CM /22 Siemens ST 70 2011

SIMATIC S7-1200 Memory Usable memory for user data 50 kbyte 50 kbyte 50 kbyte Work memory integrated 50 kbyte 50 kbyte 50 kbyte expandable No No No Load memory integrated 2Mbyte 2Mbyte 2Mbyte expandable, max. 2 Mbyte; with SIMATIC memory card 2 Mbyte; with SIMATIC memory card 2 Mbyte; with SIMATIC memory card Backup present Yes; entire project maintenancefree Yes; entire project maintenance- in the integral EEPROM free in the integral EEPROM without battery CPU-blocks Number of blocks (total) DBs, FCs, FBs, counters and timers. The maximum number of addressable blocks ranges from 1 to 65535. There is no restriction, the entire working memory can be used DBs, FCs, FBs, counters and timers. The maximum number of addressable blocks ranges from 1 to 65535. There is no restriction, the entire working memory can be used Yes; entire project maintenancefree in the integral EEPROM DBs, FCs, FBs, counters and timers. The maximum number of addressable blocks ranges from 1 to 65535. There is no restriction, the entire working memory can be used OB Number, max. Limited only by RAM for code Limited only by RAM for code Limited only by RAM for code CPU processing times for bit operations, min. 0.1 μs; / Operation 0.1 μs; / Operation 0.1 μs; / Operation for word operations, min. 12 μs; / Operation 12 μs; / Operation 12 μs; / Operation for floating point arithmetic, min. 18 μs; / Operation 18 μs; / Operation 18 μs; / Operation Data areas and their retentivity retentive data area in total (incl. times, counters, flags), max. 208byte 208byte 208byte Flag Number, max. 8 kbyte; Size of bit memory address area Address area I/O address area I/O address area, overall 102 byte for inputs / 102 byte for outputs 8 kbyte; Size of bit memory address area 102 byte for inputs / 102 byte for outputs overall 102byte 102byte 102byte Outputs 102byte 102byte 102byte Process image Inputs, adjustable 1kbyte 1kbyte 1kbyte Outputs, adjustable 1kbyte 1kbyte 1kbyte Digital channels integrated channels (DI) 1 1 1 integrated channels (DO) 10 10 10 Analog channels Integrated channels (AI) 2 2 2 Integrated channels (AO) 0 0 0 Hardware configuration Number of modules per system, max. 6ES7 21-1BE30-0XB0 6ES7 21-1AE30-0XB0 6ES7 21-1HE30-0XB0 3 comm. modules, 1 signal board, 8 signal modules 3 comm. modules, 1 signal board, 8 signal modules 8 kbyte; Size of bit memory address area 102 byte for inputs / 102 byte for outputs 3 comm. modules, 1 signal board, 8 signal modules Siemens ST 70 2011 /23

Time Clock Hardware clock (real-time clock) Backup time 20 h; typical 20 h; typical 20 h; typical Deviation per day, max. +/- 60s/month at 25 C +/- 60s/month at 25 C +/- 60s/month at 25 C Test commissioning functions Status/control Status/control variable Variables 6ES7 21-1BE30-0XB0 6ES7 21-1AE30-0XB0 6ES7 21-1HE30-0XB0 Inputs/outputs, memory bit, DB, distributed I/Os, timers, counters Inputs/outputs, memory bit, DB, distributed I/Os, timers, counters Inputs/outputs, memory bit, DB, distributed I/Os, timers, counters Forcing Forcing Communication functions S7 communication supported as server Web server supported user-defined websites Open IE communication TCP/IP ISO-on-TCP (RFC1006) Number of connections overall 15; dynamically 15; dynamically 15; dynamically 1st interface Type of interface PROFINET PROFINET PROFINET Physics Ethernet Ethernet Ethernet Isolated Automatic detection of transmission speed Autonegotiation Autocrossing Functionality PROFINET IO controller Programming Configuration software STEP 7 STEP 7 V10.5 or higher STEP 7 V10.5 or higher STEP 7 V10.5 or higher Programming language LAD FBD SCL Cycle time monitoring adjustable /2 Siemens ST 70 2011

SIMATIC S7-1200 Digital inputs Number of digital inputs 1; Integrated 1; Integrated 1; Integrated of which, inputs usable for technological functions 6; HSC (High Speed Counting) 6; HSC (High Speed Counting) 6; HSC (High Speed Counting) m/p-reading Input voltage Rated value, DC 2 V 2 V 2 V for signal "0" 5 V DC at 1 ma for signal "1" 15 V DC at 2.5 ma Input current for signal "1", typ. 1mA 1mA 1mA Input delay (for rated value of input voltage) for standard inputs - parameterizable 0.2, 0., 0.8, 1.6, 3.2, 6., and 12.8 ms, selectable in groups of four 0.2, 0., 0.8, 1.6, 3.2, 6., and 12.8 ms, selectable in groups of four - at "0" to "1", min. 0.2 ms 0.2 ms 0.2 ms - at "0" to "1", max. 12.8 ms 12.8 ms 12.8 ms for interrupt inputs - parameterizable for counter/technological functions - parameterizable Single phase : 3 at 100 khz & 1 at 30 khz, differential: 3 at 80 khz & 1 at 30 khz Cable length Cable length, shielded, max. 500 m; 50 m for technological functions Cable length unshielded, max. 300 m; For technological functions: No Digital outputs 6ES7 21-1BE30-0XB0 6ES7 21-1AE30-0XB0 6ES7 21-1HE30-0XB0 Single phase : 3 at 100 khz & 1 at 30 khz, differential: 3 at 80 khz & 1 at 30 khz 500 m; 50 m for technological functions 300 m; For technological functions: No 0.2, 0., 0.8, 1.6, 3.2, 6., and 12.8 ms, selectable in groups of four Single phase : 3 at 100 khz & 3 at 30 khz, differential: 3 at 80 khz & 3 at 30 khz 500 m; 50 m for technological functions 300 m; For technological functions: No Number of digital outputs 10 10 10 of which high-speed outputs 2; 100 khz Pulse Train Output Short-circuit protection No; to be provided externally No; to be provided externally No; to be provided externally Limitation of inductive shutdown L+ (-8 V) voltage to Switching capacity of the outputs with resistive load, max. 2A 0.5 A 2A on lamp load, max. 30 W DC; 200 W AC 5W 30 W DC; 200 W AC Output voltage for signal "1", min. 20 V Output current for signal "1" rated value 0.5 A for signal "0" residual current, max. 0.1 ma Output delay with resistive load 0 to "1", max. 10 ms; max. 1μs 10 ms; max. 1 to "0", max. 10 ms; max. 5μs 10 ms; max. Switching frequency of the pulse outputs, with resistive 1Hz 100 khz 1Hz load, max. Cable length Cable length, shielded, max. 500 m 500 m 500 m Cable length unshielded, max. 150 m 150 m 150 m Siemens ST 70 2011 /25

Relay outputs Number of relay outputs 10 10 Number of operating cycles 6ES7 21-1BE30-0XB0 6ES7 21-1AE30-0XB0 6ES7 21-1HE30-0XB0 mechanically 10 million, at rated load voltage 100,000 mechanically 10 million, at rated load voltage 100,000 Analog inputs Number of analog inputs 2 2 2 Cable length, shielded, max. 100 m; twisted and shielded 100 m; twisted and shielded 100 m; twisted and shielded Input ranges Voltage Input ranges (rated values), voltages 0 to +10 V Input resistance (0 to 10 V) 100 kohm 100 kohm 100 kohm Analog outputs Cable length Cable length, shielded, max. 100 m; Shielded, twisted wire pair 100 m; Shielded, twisted wire pair 100 m; Shielded, twisted wire pair Analog value creation Integrations and conversion time/ resolution per channel Resolution with overrange (bit including sign), max. 10 bit 10 bit 10 bit Integration time, parameterizable Conversion time (per channel) 625 μs 625 μs 625 μs Encoder supply 2 V encoder supply 2 V permissible range: 20. to 28.8 V permissible range: 20. to 28.8 V permissible range: 20. to 28.8 V Encoder Connectable encoders 2-wire BEROS Integrated Functions Number of counters 6 6 6 Counter frequency (counter) max. 100 khz 100 khz 100 khz Frequency meter controlled positioning PID controller Number of alarm inputs Number of pulse outputs 2 Limit frequency (pulse) 100 khz Operator control and monitoring Display Integrated No No No Galvanic isolation Galvanic isolation digital inputs Galvanic isolation digital inputs No No No between the channels, in groups of 1 1 1 Galvanic isolation digital outputs Galvanic isolation digital outputs Yes; Relays Yes Relays between the channels No No No between the channels, in groups of 2 2 1 /26 Siemens ST 70 2011

SIMATIC S7-1200 Permissible potential difference between different circuits 500 V DC between 2 V DC and 5 V DC 500 V DC between 2 V DC and 5 V DC EMC Interference immunity against discharge of static electricity Interference immunity against discharge of static electricity acc. to IEC 61000--2 - Test voltage at air discharge 8kV 8kV 8kV - Test voltage at contact discharge 6kV 6kV 6kV Interference immunity to cable-borne interference on the supply lines acc. to IEC 61000-- Interference immunity on signal lines acc. to IEC 61000-- Surge immunity on the supply lines acc. to IEC 61000--5 Immunity against conducted interference induced by high-frequency fields Interference immunity against highfrequency radiation acc. to IEC 61000--6 Emission of radio interference acc. to EN 55 011 Emission of radio interferences acc. Yes; Group 1 Yes; Group 1 Yes; Group 1 to EN 55 011 (limit value class A) Emission of radio interference acc. to EN 55 011 (limit value class B) Climatic and mechanical conditions for storage and transport Climatic conditions for storage and transport Free fall - Drop height, max. (in packaging) 0.3 m; five times, in dispatch package 6ES7 21-1BE30-0XB0 6ES7 21-1AE30-0XB0 6ES7 21-1HE30-0XB0 0.3 m; five times, in dispatch package 500 V DC between 2 V DC and 5 V DC 0.3 m; five times, in dispatch package Temperature - Permissible temperature range -0 C to +70 C -0 C to +70 C -0 C to +70 C Relative humidity - Permissible range (without condensation) at 25 C 95% 95% 95% Siemens ST 70 2011 /27

Mechanical and climatic conditions during operation Climatic conditions in operation Temperature - Permissible temperature range 0 C to 55 C horizontal mounting, 0 C to 5 C vertical mounting 0 C to 55 C horizontal mounting, 0 C to 5 C vertical mounting - Permissible temperature change 5 C to 55, 3 C/minute 5 C to 55 C, 3 C / minute 5 C to 55 C, 3 C / minute Air pressure acc. to IEC 60068-2-13 - Permissible air pressure 1080 to 795 hpa 1080 to 795 hpa 1080 to 795 hpa - Permissible operating height -1000 to 2000 m -1000 to 2000 m -1000 to 2000 m Pollutant concentrations -SO 2 at RH < 60% without condensation S0 2 : < 0.5 ppm; H2S: < 0.1 ppm; RH < 60% condensation-free S0 2 : < 0.5 ppm; H 2 S: < 0.1 ppm; RH < 60% condensation-free S0 2 : < 0.5 ppm; H 2 S: < 0.1 ppm; RH < 60% condensation-free Environmental requirements Operating temperature Min. 0 C 0 C 0 C Max. 55 C 55 C 55 C Vertical installation, min. 0 C 0 C 0 C Vertical installation, max. 5 C 5 C 5 C Horizontal installation, min. 0 C 0 C 0 C Horizontal installation, max. 55 C 55 C 55 C Storage/transport temperature Min. -0 C -0 C -0 C Max. 70 C 70 C 70 C Air pressure Operation, min. 795 hpa 795 hpa 795 hpa Operation, max. 1080hPa 1080hPa 1080hPa Storage/transport, min. 660 hpa 660 hpa 660 hpa Storage/transport, max. 1080hPa 1080hPa 1080hPa Relative humidity Operation, max. 95 %; no condensation 95 %; no condensation 95 %; no condensation Vibrations Vibrations 2G wall mounting, 1G DIN rail 2G wall mounting, 1G DIN rail 2G wall mounting, 1G DIN rail Operation, checked according to IEC 60068-2-6 Shock test checked according to IEC 60068-2-27 6ES7 21-1BE30-0XB0 6ES7 21-1AE30-0XB0 6ES7 21-1HE30-0XB0 Yes; IEC 68, Part 2-27 half-sine: Strength of the shock 15 g (peak value), duration 11 ms Yes; IEC 68, Part 2-27 half-sine: Strength of the shock 15 g (peak value), duration 11 ms Degree of protection IP20 Standards, approvals, certificates CE mark C-TICK culus FM approval Dimensions and weight Dimensions Width 110 mm 110 mm 110 mm Height 100 mm 100 mm 100 mm Depth 75 mm 75 mm 75 mm Weight Weight, approx. 55 g 15 g 35 g Yes; IEC 68, Part 2-27 half-sine: Strength of the shock 15 g (peak value), duration 11 ms /28 Siemens ST 70 2011

SIMATIC S7-1200 Ordering data Order No. Order No. Compact CPU, AC/DC/relay; I 6ES7 21-1BE30-0XB0 integral program/data memory 50 KB, load memory 2 MB; wide-range power supply 85... 26 V AC; Boolean execution times 0.1 s per operation; 1 digital inputs, 10 digital outputs (relays), 2 analog inputs; expandable by up to 3 communication modules, 8 signal modules and 1 signal board/communication board; digital inputs can be used as HSC at 100 khz Compact CPU, DC/DC/DC; I 6ES7 21-1AE30-0XB0 integrated program/data memory 50 KB, load memory 2 MB; power supply 2 V DC; Boolean execution times 0.1 s per operation; 1 digital inputs, 10 digital outputs, 2 analog inputs; expandable by up to 3 communication modules, 8 signal modules, and 1 signal board/communication board; digital inputs can be used as HSC at 100 khz, 2 V DC digital outputs can be used as pulse outputs (PTO) or pulse-width modulated outputs (PWM) at 100 khz Compact CPU, DC/DC/relay; I 6ES7 21-1HE30-0XB0 integrated program/data memory 50 KB, load memory 2 MB; power supply 2 V DC; Boolean execution times 0.1 s per operation; 1 digital inputs, 10 digital outputs (relays), 2 analog inputs; expandable by up to 3 communication modules, 8 signal modules, and 1 signal board/communication board; digital inputs can be used as HSC at 100 khz SB 1221 signal board inputs, 5 V DC, 200 khz I 6ES7 221-3AD30-0XB0 inputs, 2 V DC, 200 khz I 6ES7 221-3BD30-0XB0 SB 1222 signal board outputs, 5 V DC, 0.1 A, 200 khz I 6ES7 222-1AD30-0XB0 outputs, 2 V DC, 0.1 A, 200 khz I 6ES7 222-1BD30-0XB0 SB 1223 signal board 2 inputs, 2 V DC, IEC type 1 I 6ES7 223-0BD30-0XB0 active high; 2 2 V DC transistor outputs, 0.5 A, 5 W; can be used as HSC at up to 30 khz 2 inputs, 5 V DC, 200 khz I 6ES7 223-3AD30-0XB0 2 outputs 5 V DC, 0.1 A, 200 khz 2 inputs, 2 V DC, 200 khz I 6ES7 223-3BD30-0XB0 2 outputs 2 V DC, 0.1 A, 200 khz SB 1231 signal board I 6ES7 231-HA30-0XB0 1 analog input, ±10 V with 12 bit or 0... 20 ma with 11 bit SB 1231 thermocouple signal I 6ES7 231-5QA30-0XB0 board 1 input +/- 80 mv, resolution 15 bit + sign, thermocouples type J, K SB 1231 RTD signal board I 6ES7 231-5PA30-0XB0 1 input for resistance temperature sensors Pt 100, Pt 200, Pt 500, Pt 1000, resolution 15 bit + sign SB 1232 signal board I 6ES7 232-HA30-0XB0 1 analog output, ±10 V with 12 bit or 0 to 20 ma with 11 bit CB 121 RS85 I 6ES7 21-1CH30-1XB0 communication board for point-to-point connection, with 1 RS85 interface Simulator (optional) 1 input switches, for I 6ES7 27-1XH30-0XA0 SIMATIC memory card (optional) 2 MB I 6ES7 95-8LB01-0AA0 2 MB I 6ES7 95-8LF01-0AA0 Extension cable for two-tier I 6ES7 290-6AA30-0XA0 configuration for connecting digital/analog signal modules; length 2 m Terminal block (spare part) for For DI, with 20 screws, tin-plated; I 6ES7 292-1AV30-0XA0 units For DO, with 12 screws, I 6ES7 292-1AM30-0XA0 tin-plated; units For AI, with 3 screws, tin-plated; units I 6ES7 292-1BC30-0XA0 I: Subject to export regulations AL: N and ECCN: EAR99H Siemens ST 70 2011 /29

Ordering data Order No. Order No. Front flap set (spare part) for 6ES7 291-1AB30-0XA0 S7-1200 automation system, system manual For SIMATIC S7-1200 and STEP 7 Basic German K 6ES7 298-8FA30-8AH0 English K 6ES7 298-8FA30-8BH0 French K 6ES7 298-8FA30-8CH0 Spanish K 6ES7 298-8FA30-8DH0 Italian K 6ES7 298-8FA30-8EH0 Chinese K 6ES7 298-8FA30-8KH0 S7-1200 automation system, Easy Book Brief instructions German K 6ES7 298-8FA30-8AQ0 English K 6ES7 298-8FA30-8BQ0 French K 6ES7 298-8FA30-8CQ0 Spanish K 6ES7 298-8FA30-8DQ0 Italian K 6ES7 298-8FA30-8EQ0 Chinese K 6ES7 298-8FA30-8KQ0 STEP 7 Basic V11 engineering software Target system: SIMATIC S7-1200 controllers and the associated I/O. Requirements: Windows XP Home SP3, Windows XP Professional SP3 (32 bit), Windows 7 Home Premium, Windows 7Professional (32 bit), Windows 7 Enterprise (32 bit), Windows 7 Ultimate (32 bit), Microsoft Server 2003 R2 Std. SP2 (32 bit), Microsoft Server 2008 Std. SP2 (32 bit) Type of delivery: German, English, Chinese, Italian, French, Spanish Single license Upgrade STEP 7 Basic V10.5 to STEP 7 Basic V11, single license Powerpack STEP 7 Basic V11 to STEP 7 Prof. V11, floating license STEP 7 Basic V11, trial license STEP 7 Basic Software Update D Service, 1 year 6ES7 822-0AA01-0YA0 6ES7 822-0AA01-0YE0 6ES7 822-1AA01-0YC5 6ES7 822-0AA01-0YA7 6ES7 822-0AA00-0YL0 D: Subject to export regulations AL: N and ECCN: 5D992 K: Subject to export regulations AL: N and ECCN: EAR99T /30 Siemens ST 70 2011