Type Test Report Rapport d essais

Similar documents
VBS TBS KTS BSS LFS UFS

Your passport to success TECHNICAL OVERVIEW

Isolating Spark Gaps. Isolating spark gaps at an additional earth ring conductor. Isolating spark gaps for Ex zones

RAIL MOUNTED NETWORK METER TYPE N27D USER S MANUAL

Instruction Manual TABLE OF CONTENTS 1 PRINCIPLE OF OPERATION Limitations INSTALLATION Mains connection...

PRODUCT FOR HIGH VOLTAGE APPLICATION. Current transformers for Gasinsulated. Instructions for installation, use and maintenance

Description. Annexe to: IECEx CML X Issue 1. Isolating Amplifier D461

Electronic timer CT-ERS ON-delayed with 2 c/o contacts Data sheet

Auxiliary Contact (10 600V) Auxiliary Contact (10 5V DC)

P2 H2 NAMEPLATE 6 HOLES M8-10 M SCREW S1 1S2 1S3 X1 X2 X3 PARALLEL HIGH RATIO

DATA SHEET Selectable AC transducer TAS-311DG

METERSUK. SmartLink D Y N A M i T E. EM735 S Series. User Manual KEY FEATURES INDEX 3. TECHNICAL DESCRIPTION.

Electronic timer CT-AWS Impulse-OFF with 1 c/o contact Data sheet

TRANSFORMERS FOR GIS APPLICATIONS VOLTAGE VOLTAGE TRANSFORMERS FOR GIS APPLICATIONS

SECULIFE SR PC Controllable Instrument for Measuring Safety-Relevant Characteristic Values of Electrical Devices /2.

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

Computer-14d - xx - 144a

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC

Electronic relays. Monitoring. Monitoring

3 - Protection components Circuit-breakers

American Power Design, Inc.

Current / residual current and voltage transformers. Current / residual current and voltage transformers

SRA 2250/6 RESISTOR ARS-01 RESISTOR AUTOMATICS

ARC-MC. Data warehousing board for drivers, measuring and monitoring board for power systems

IGS IGS-M-EL-22(1) Contactors APPROVED. Iranian Gas Standards

Voir Annexe See Annex. Socle fixe de prise de courant Fixed socket-outlet 16 A, 250 V~ NF C :2008 +A1:2010

CB TEST CERTIFICATE. Uninterruptible Power Supply. Additional Information on page 2 BK500...

Series P. Applications

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009

SPTS 1 - Ratings and General Requirements for Plant, Equipment and Apparatus for The ScottishPower System and Connection Points to it.

I -limiter The world s fastest switching device

Isolators A3/1. Ex i Power Supply Field Circuit Ex i Series

Technical data. Safety notes

Modular equipment. Presentation, standards. Standard contactors TeSys GC

1/23/2003. Sensor presentation

Gas-Insulated Medium-Voltage Switchgear siemens.com/8dab12

400,440Vac Vdc V, A, W, VA, var, Hz, V, Avg. A cos phi, sin phi and phi measurement kwh, kvarh (via Pulse Output)

Specifications Approval Type M12 A-coded HARAX M12-L HARAX M12 L 5 poles shielded M12 Crimp General data Electrical characteristics Materials 03 21

Standards for MV switchgear rated for arc flash protection

2007 DEHN + SÖHNE / protected by ISO EXFS / 5392

Specification for Lightning Sensor

ENERGY SAVINGS WITH VARIABLE SPEED DRIVES ABSTRACT. K M Pauwels. Energy auditor, Laborelec, Industrial Applications, Belgium

Motor-protective circuit-breaker, 3p, Ir=40-50A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

Technical Data Sheet. Zeta 20

Spectrum Sharing 900 MHz Combiner

MEDIUM VOLTAGE PRODUCT. TJP 5.x Indoor voltage transformers

SINEAX V 624 Programmable Temperature Transmitter for RTD and TC inputs

ELECTRICAL NETWORKS SPECIFICATION TECHNICAL SPECIFICATION FOR A 230V/110V AND 400V/110V TRANSFORMER

INDUSTRIAL OPTO-ISOLATED RS-232 REPEATER

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Measuring current transformers of the W, W series

Solid-state Timer H3DS

ControlNet Modular Repeater Medium Distance Fiber Module

OUTDOOR VOLTAGE TRANSFORMERS (Indoor units available) Description:

DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER

Protection and safety SQZ3 phase and sequence relay

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

6. Internal lightning protection

MBS AG. KBR 18 Split-core current transformer. Further information about our new split-core current transformer KBR 18: Dimensions:

SIMEAS-T. Operating Instructions Transducer without auxiliary power. 7KG6111 and 7KG6101. Operating Instructions

TT 0710/03. TYPE TEST OF 3 Phase Solid Earthing Bonding Link Box, Type: LB.W.3SA.3.1

Sensor Technology. Applications for medium voltage

PowerLogic power-monitoring units. PM700 series power meter. Technical data sheet

TECHNICAL DESCRIPTION TD-77A/3 170 KV COMPACT GAS INSULATED INTEGRATED SUBSTATION MODULES

LDW240 Series are single, two or three phase DIN Rail Switching Power Supplies.

Monitoring Electric Network Via Internet

Medium-voltage transfomers

EMC Data Sheet CSD100 Model size 4 to 6. Variable Speed AC drive for permanent magnet motors

American Power Design, Inc.

Choosing the correct Furse ESP Lightning Barrier for your application

Datasheet - ZQ N

American Power Design, Inc.

SYNCHRONISM RELAY SYNCRO-96. (Code ) INSTRUCTION MANUAL ( M / 99A ) (c) CIRCUTOR S.A.

onlinecomponents.com

INSTALLATION MANUAL Model 1923 Load Cells Certified for Explosion Safety na Non-Sparking

MICRO-SCREEN DIN Module Controllers

Data sheet Cable connector class F A

About us. Vision. To lead our field in innovation, quality and customer service.

Index. Capacitor Switching - 2 Contactors. Typical Circuit Diagram 2. Auxiliary Contact Blocks 2. Contactors 3. Dimensions 3. Technical Data 4,5,6

DATA SHEET AC current single function transducer TAC-311DG/TAC-321DG

8.3. Terminal Blocks, Fuse Blocks and Fuse Holders. Contents Description. CHDB Series Power Distribution Blocks. Power Distribution

LINAX 4000L Continuous-line recorder

Protection components

LDW25-24 is a single or two phase AC or DC input DIN Rail Switching Power Supply.

MINISTRY OF ELECTRICITY

Overcurrent Protection / 7SJ45

Differential pressure sensors

EMC Data Sheet Unidrive-M Model size 3. Variable Speed AC drive for induction and permanent magnet motors

SINEAX TI 807 Passive DC signal isolator. SINEAX TI 807 Passive DC signal isolator

POWER FACTOR CORRECTION. HARMONIC FILTERING. MEDIUM AND HIGH VOLTAGE SOLUTIONS.

MESP TECHNICAL SPECIFICATION FOR AN ESSENTIAL SERVICES SUPPLY STEP UP TRANSFORMER

LC1D25BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A - 24 V DC coil

Description Basic devices with positive operation contacts

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID

Powered by technology...driven by service CURRENT TRANSFORMERS. Multifunction Meters. Transducers & Isolators. Temperature Controllers

ZS8.4 Air-insulated medium voltage switchgear

SINEAX TI 807 Passive DC signal isolator

Switching power supplies CP range, Linear power supplies CP-L range. Content

Capacitive voltage transformers

LC2D09BL REVERSING CONTACTOR 575VAC 9A IEC

Transcription:

TRANSMISSION & DISTRIBUTION Appareillage moyenne tension Type Test Report Rapport d essais No 2193 Test object : Matériel à essayer : Type : Type : Manufacturer and client : Constructeur : Test Laboratory : Laboratoire d essais : Location of tests : Lieu d essais : Date of tests : Date des essais : Test Specification : Normes d essais : Tests performed : Essais réalisés : Test results : Résultats des essais : Switch fuses combination feeder of compact GIS + connecting kit + voltage transformer functional unit Combiné interrupteur fusible d un tableau compact à isolation dans le gaz + kit de raccordement + UF transformateur de tension FBA T + FBVT Panel AREVA T&D Belgium SA Dison AREVA T&D Belgium SA Dison - Test laboratory - Laboratoire d essai - November 4 th 2004 4 novembre 2004 IEC 62271-200, IEC 60529 and TST 19-2 1.2.11 Degrees of protection provided by enclosures (IP Code) Degré de protection procuré par l enveloppe (code IP) The requirements were met. Les essais sont concluants Dison, 18/11/04 D. Melchior Test Platform Engineer Ingénieur plate-forme d essai P. Thiry Manager technology & certification Responsable technologie & certification

Rep2193.typ.doc Page 2 Contents Sommaire 1. Technical data of the test object Caractéristiques techniques du matériel à essayer 2. Dimensional drawing Plan d encombrement 3. Participants in the tests Participants aux essais 4. Test object Matériel à essayer 5. Test arrangement Conditions d essais 6. Test and measuring circuits Schémas d essais et de mesure 7. List of measuring instruments Liste des instruments de mesure 8. Test results Résultats des essais 9 Oscillograms Oscillogrammes 10. Photos Photos 11. Drawings Plans Page 3 4 5 5 5-5 6-7 7 This Type Test Report consists of 7 pages.

Rep2193.typ.doc Page 3 1. Technical data of the test object General characteristics : FBVT panel Width of cubicle Depth of cubicle Height of cubicle Rated voltage Rated lightning voltage Up Rated power frequency voltage Ud 550 mm 500 mm 650 mm 17.5 kv 95 kv 38kV Voltage transformer Type 2VB24 (DIN) Manufacturer ALCE Rating plate : U1 11000 V 1.2 Un (max 17.5kV) 17.5/38/95 kv - 50Hz U2 110 V VA 500 Cl 3 Ith 4.54 A

Rep2193.typ.doc Page 4 2. Dimensional drawing

Rep2193.typ.doc Page 5 3. Participants in the tests J.P. Haegeman Laborelec D. Melchior AREVA - EIB 4. Test object The test object is a FBVT panel : air insulated metal enclosed switchgear including 1 phase to phase voltage transformer DIN type 2VB24 manufactured by ALCE. Condition before tests : brand-new 5. Test arrangement The test object is new and completely assembled as in service. Panel fitted with 2 single phase shielded cables type EXCVB 8.7/15kV 1*25mm² Cu. Photos of test object and test arrangement can be found on page 7. 6. Test and measuring circuits None 7. List of measuring instruments Test fingers from Laborelec.

Rep2193.typ.doc Page 6 8. Test results Protection degree for enclosures against penetration of solid object and against access to hazardous part Part under test Required Observed Bottom side IP2X IP4X Rear side IP2X IP4X Front side IP2XC IP4X Lateral side IP2XC IP4X Upper side IP2XC IP4X By this it is proved that the requirements are met. 9. Oscillograms None

Rep2193.typ.doc Page 7 10. Photos 11. Drawings Name of the drawing Number Assembly drawing of the FBVT panel EIBBE0028-01 ed.04 2VB24 DIN voltage transformer 375 ed.3 Wiring diagram EIBBS0015 ed.02 Excepted the general view of the FBVT panel, the drawings are kept in the laboratory file