GIGABIT ETHERNET. e-ready Building Next Generation IT infrastructures. The Cabling Partnership. Mike Gilmore Managing Director, e-ready Building

Similar documents
HIGH BIT RATE OPTICAL FIBRE NETWORKS - optical fibre selection and implementation

- Characteristic impedance of cabling links is characterised by Return Loss

Pluggable Transceiver Modules

Data sheet OpDAT breakout cable 24x1 OM4 - bend insensitive

TECHNICAL ARTICLE: DESIGN BRIEF FOR INDUSTRIAL FIBRE OPTICAL NETWORKS

Fiber Optic Principles. Oct-09 1

Outside Plant All Dielectric

Industrial Automation

How Bend Insensitive Multimode Fiber is Affecting Installation and Testing of Enterprise and Data Center Cabling

One Enterprise. One Infrastructure. One Partner. Optical Fiber Loss Testing. Optical loss testing in the field is not as simple as it seems.

400G-BD4.2 Multimode Fiber 8x50Gbps Technical Specifications

Single-Armored Cables, Fibers

There are lots of problems or challenges with fiber, Attenuation, Reflections, Dispersion and so on. So here we will look at these problems.

OpDAT Universalkabel 1x4 OM4 - biegeunempfindlich, Klasse. Principle diagram

ALTOS Lite Gel-Free, Single-Jacket, Single-Armored Cables, Fibers

Outdoor, Fig 8 Armored, Multi Tube

NEW YORK CITY COLLEGE of TECHNOLOGY

OPTICAL TECHNOLOGY TRAINING

DELL EMC NETWORKING TRANSCEIVERS AND CABLES

P802.3cd Clause 138 hazard level recommendations. P802.3cd Interim meeting, May 2017 Richard Johnson and Jonathan King, Finisar

Data sheet OpDAT connection cable 2x1 OS2 - bend insensitive

BICSI Standards Update December Stephen Banks RCDD CDCDP

Fibre Optic Indoor/Outdoor Cable

features and benefits

Outdoor, CCTV or CCTV, Fig 8 Armored.

Optical Fiber and PMD. Reach and Economics for EFM

The Future of Cabling -

Improvements to Modal Noise Penalty Calculations

Variation of Waveforms in Multimode Fibre

Comment Supporting materials: The Reuse of 10GbE SRS Test for SR4/10, 40G-LR4. Frank Chang Vitesse

af-phy July 1996

FiberHome Fiber Products

Information technology. Generic cabling systems, General requirements

Multimode fiber media types for 802.3cd

Ø560*336mm 4.25 kg 2100 ± 105m

Exhibit A Construction Project Manual and Drawings

Provläsningsexemplar / Preview TECHNICAL REPORT. Fibre optic communication system design guides

Lectureo5 FIBRE OPTICS. Unit-03

Transceiver, Chassis Connectors, and Cable and Adapter Specifications

GUXW. Mini-Breakout Cables (Distribution) Universal Indoor/ Outdoor, Steel Wire Armor (SWA) A/I-VQ(ZN)HBH Full Rodent Protection v5.

WHITE PAPER LINK LOSS BUDGET ANALYSIS TAP APPLICATION NOTE LINK LOSS BUDGET ANALYSIS

Class 1 LED of 850 nm for (short-range) applications. Class 1 laser of 1300 nm for (medium-range) applications.

Total care for networks. Introduction to Dispersion

Technical Specifications

τ mod = T modal = longest ray path shortest ray path n 1 L 1 = L n 2 1

Pluggable Transceivers

The fundamental differences between OM5 and OM4+ fiber

Migration to 50/125 µm in the Local Area Network

GYM Bilgi Teknolojileri

Chapter 3 Signal Degradation in Optical Fibers

User Manual. Installation Transmit Receive Module SFP/XFP

Specification for 100GBASE-DR4. Piers Dawe

100G CWDM4 MSA Technical Specifications 2km Optical Specifications

1300nm Fast Ethernet Transceiverin1x9SC Duplex Package

Guided Propagation Along the Optical Fiber. Xavier Fernando Ryerson Comm. Lab

WDM Alternatives for 100Gb SMF Applications

Introduction of 25 Gb/s VCSELs

Optical Communications and Networks - Review and Evolution (OPTI 500) Massoud Karbassian

10GBASE-S Technical Feasibility

Bending the Truth - Get the straight story about Corning ClearCurve multimode fibers

HES HACILAR ELEKTRİK SANAYİ VE TİC.A.Ş.

Optical networking. Emilie CAMISARD GIP RENATER Optical technologies engineer Advanced IP Services

IEEE July 2001 Plenary Meeting Portland, OR Robert S. Carlisle Sr. Market Development Engineer

400G-FR4 Technical Specification

Technical Specifications

Fiber Optic Communications Communication Systems

GORN. Central Loose Tube Cables Outdoor A-DQ(ZN)B2Y Improved Rodent Protection, 1000N Permanent Load v6.0. Ordering Information

Standard Monotube SAFE

Instalaciones de fibra óptica en entornos de centros de datos y campus para suportar 40, 100g y más

JFOC-BSG2D MODEL:JFOC-BSG2D. optic.com. For detailed inquiry please contact our sales team at:

Product Specification RoHS-6 Compliant 10Gb/s 850nm Multimode Datacom XFP Optical Transceiver

Why Using Fiber for transmission

CXP/CFP 100G MPO Cable Assembly

400G CWDM8 10 km Optical Interface Technical Specifications Revision 1.0

Variation in Multimode Fiber Response: Summary of Experimental Results

White Paper: The Ins and Outs of Testing Bend Insensitive Multimode Fiber (BIMMF): The Need for Encircled Flux

Evaluating 10GBASE-SX CWDM

DESCRIPTION. These transceivers also support 10 Base Fx 1300 nm with DC-free Single power supply (3.3 V)

Product Specification. RoHS-6 Compliant 10Gb/s 850nm Multimode Datacom XFP Optical Transceiver FTLX8511D3

AC : FIBER OPTICS COURSE FOR UNDERGRADUATE ELECTRICAL ENGINEERING STUDENTS

10GBd SFP+ Short Wavelength (850nm) Transceiver

Extending 100Gbit/s Ethernet. Ariën Vijn

Measurement Considerations for Corning ClearCurve LBL and ZBL Optical Fiber

Nufern 980 nm Select Cut-Off Single-Mode Fiber

Presentation Overview

OPTICAL MEASURING INSTRUMENTS. MW9060A 1.31/1.55 µm (SM), 0.85/1.3 µm (GI) OPTICAL TIME DOMAIN REFLECTOMETER GPIB

Betz & Limbach Projektkabel GmbH, Ringstraße 43, Bretzfeld, Tel / , Fax -58

Chapter 8. Digital Links

XFP-10GER-192IR V Operating Environment Supply Voltage 1.8V V CC V Operating Environment Supply Current 1.8V I CC1.

TIA FO Task Group on Modal Dependence of Bandwidth. 7/99 Status Update

Introduction to Fiber Optics

QSFP. Parameter Symbol Min Max Unit Notes. Relative Humidity (non-condensation) RH 0 85 %

ITU-T G.656. Characteristics of a fibre and cable with non-zero dispersion for wideband optical transport

XFP 10G MM SR. 10Gbps XFP Optical Transceiver, 300m Reach

Advanced Fibre Testing: Paving the Way for High-Speed Networks. Trevor Nord Application Specialist JDSU (UK) Ltd

Parameter Fiber Type Modal 850nm (MHz-km) Distance Range (m) 62.5/125um MMF /125um MMF

Teaching fiber-optic communications in engineering technology programs by virtual collaboration with industry

V23818-C8-V10. Small Form Factor Multimode 1300 nm LED Ethernet/Fast Ethernet/FDDI/ATM 155/194 MBd Transceiver. Preliminary. Dimensions in inches (mm)

Lecture 5 Transmission. Physical and Datalink Layers: 3 Lectures

Product Specification. Industrial Temperature Range 10Gb/s 850nm Multimode Datacom XFP Optical Transceiver FTLX8512D3BTL

Transcription:

Mike Gilmore Managing Director,

Mike Gilmore Standards Activities Member: ISO/IEC JTC1 SC25 WG3: Generic Cabling ISO/IEC JTC1 SC25 Project Team: SOHO Convenor: ISO/IEC JTC1 SC25 WG3 IPTG: Industrial Premises Cabling Convenor: CENELEC TC215 WG1: IT Cabling CENELEC TC215 WG1 PT Industrial Premises Cabling Secretary: CENELEC TC215 WG1 PT Data Centre Cabling Mike Gilmore Senior Partner, Managing Director Chairman: BSI TCT7/-/1: IT Cabling BSI TCT7/-/3: IT Cabling Support Group Technical and Standards Director: Fibreoptic Industry Association e-mail: mike.gilmore@btinternet.com Mobile: +44 () 786 11563

Optical Fibre Transmission Wavelengths VISIBLE LIGHT FRA-RED - OPTICAL FIBRE O E S L C Bands 1st Window 2nd Window 3rd Window 4 5 6 7 8 9 1 11 12 13 14 15 16 17 Wavelength (nm) Multimode 85 nm Window Wavelength (nm) 1st 79-85 - 91 Band Wavelength (nm) Singlemode 131 nm 2nd 1285-13 - 133 O 1285-135 Multimode 13 nm E S L 135-147 147-153 153-1565 C 1565-1625 Singlemode 155 nm

MMF: Attenuation and Modal Bandwidth Optical fibre geometry (standardized) 5/125 62.5/125 Core diameter (µm) 5 ± 3 62.5 ± 3 Cladding diameter (µm) 125 ± 3 125 ± 3 NA.2 ±.15.275 ±.15 Optical fibre performance (options) Attenuation coefficient dbkm -1 max. 85nm 13nm?? Modal bandwidth MHz.km min. 85nm 13nm?? 3.5 dbkm -1 1.5 dbkm -1 Attenuation coefficient (dbkm -1 ) 5 7 9 11 13 Wavelength (nm) Modal Bandwidth (MHz) 2 15 2MHz.km MMF 1 5 5 1 15 2 Length (m)

Optical Fibre Categories CABLED OPTICAL FIBRE Attenuation coefficient (dbkm -1 max) Modal bandwidth OFL 1 (MHz.km min) Modal bandwidth LL 2 (MHz.km min) Propagation delay (ns.m -1 max) Wavelength 85nm 13nm 85nm 13nm 85nm 13nm 85nm 13nm ISO/IEC 1181 Ed. 2 (22) AND EN 5173-1 (22) MMF SMF 5/125 or 62.5/125 5/125 OM1 OM2 OM3 Wavelength OS1 3,5 131nm 1, 1,5 155nm 1, 2 5 15 5 5 5 - - 2 - - - 5 131nm 155nm 5 OS2* OS1 1,,4,4 1, 5 NOTE 1: OFL = OverFilled Launch (LED-like) NOTE 2: LL (or RL) = LASER Launch ( or Restricted Launch) * standard in development

Optical Fibre Applications Mbs -1 1 1 4/16 52 1 1 1 1 1 133 155 266 531 622 1 162 1 NETWORK NAME ISO/IEC 882-3: FOIRL ISO/IEC 882-3: 1BASE-FL/FB ISO/IEC TR 1182-4: 4 & 16 Mb/s Token Ring M ISO/IEC 882-12: Demand priority ISO/IEC 9314-3: FDDI PMD ISO/IEC 9314-4: FDDI SMF-PMD ISO/IEC 9314-9: FDDI LCF-PMD ISO/IEC 882-3: 1BASE-FX ISO/IEC 14165: FibreChannel M ISO/IEC 14165: FibreChannel ISO/IEC 14165: FibreChannel M IEEE 82.3ab: 1BASE: Ethernet ISO/IEC 14165: FibreChannel IEEE 82.3ae: 1GBASE-xyz: Ethernet WAVELENGTHS AND MODAL GROUPS MMF SMF 85 nm 13 nm 131 nm 155 nm 1BASE -SX 1BASE -LX 1BASE -LX -SR/SW -LX4* -LX4* /LR/LW -ER/EW * 1GBASE-LX4 uses Coarse WDM (CWDM) λ 1 = 127±1 (Lane 1) λ 2 = 13±6 (Lane 2) λ 3 = 1325±6 (Lane 3) λ 4 = 1349±1 (Lane 4)

MMF Applications WAVELENGTHS MMF Mbs -1 NETWORK NAME 85 nm 13 nm 1 1 ISO/IEC 882-3: 1BASE-FL/FB ISO/IEC 882-3: 1BASE-FX 1 IEEE 82.3ab: 1BASE: Ethernet 1BASE -SX 1BASE -LX 1 IEEE 82.3ae: 1GBASE-xyz: Ethernet -SR/SW -LX4 Mbs -1 1 1 1 1 NETWORK NAME ISO/IEC 882-3: 1BASE-FL/FB ISO/IEC 882-3: 1BASE-FX IEEE 82.3ab: 1BASE-SX: Ethernet IEEE 82.3ab: 1BASE-LX: Ethernet IEEE 82.3ae: 1GBASE-SR/SW: Ethernet IEEE 82.3ae: 1GBASE-LX4: Ethernet MAXIMUM CHANNEL LENGTH (CHANNEL SERTION LOSS MAX. LENGTH) MMF OM1 OM2 OM3 2 m (12.5 db) 2 m (6.8 db) 2 m (6.8 db) 2 m (11. db) 2 m (6.3 db) 2 m (6.3 db) 275 m (2.6 db) 55 m (3.56 db) 9 m* (4.44 db*) 55 m (2.35 db) 33 m (1.62 db) 82 m (1.8 db) 3 m (2.59 db) 3 m (1.96 db) 3 m (1.96 db) * Inferred values

Connecting Hardware CONNECTG HARDWARE Return loss (db min) Attenuation (db max) ISO/IEC 1181 Ed. 2 (22) AND EN 5173-1 (22) MMF OM1, OM2, OM3 Wavelength Connection Splice All 2 NA All 95%<,5 1%<,75 1%<,3 Wavelength All All SMF OS1, OS2 Connection Splice 35 NA 95%<,5 1%<,3 1%<,75 CONNECTG HARDWARE EQUIVALENT LENGTH MMF 85 nm 13 13 nm nm Mated connection Splice Mated connection Splice,75 db,3 db,75 db,3 db 215 m 85 m 5 m 2 m SMF 131 nm 155 13 nm nm Mated connection Splice Mated connection Splice,75 db,3 db,75 db,3 db 1875 m 75 m 1875 m 75 m

1BASE-FL/FB Attenuation (db, max.) 12 1 8 6 Connecting hardware allowance 62.5/125 OPB 62.5/125 OPB 5/125 3.5dBkm -1 4 Connecting hardware allowance 5/125 2 5 1 15 2

1BASE-FL/FB 12 1 OPB 62.5/125 Attenuation (db, max.) 8 6 OPB 5/125 3.5dBkm -1 4,75dB = 215 m 2 5 1 15 2

1BASE-SX - The Big Misconception 8 7 6 5 Attenuation (db, max.) 4 3 3.56dB 2 1 Connecting hardware allowance 55m 3.5dBkm -1 (corrected to 83nm) 2 4 6 8 1 OM1 62,5/125 OM2 5/125

1BASE-SX and 62.5/125 8 7 6 OPB Attenuation (db, max.) 5 4 3MHz 3 2 Connecting hardware allowance 16MHz OM2 3.5dBkm -1 (corrected to 83nm) 1 2 4 6 8 1

1BASE-SX and 62.5/125 8 7 6 OPB 5,75dB = 65 m Attenuation (db, max.) 4,75dB = 35 m 3MHz 3 OM2 3.5dBkm -1 (corrected to 83nm) 2 16MHz 1 2 4 6 8 1

1BASE-SX and 5/125 8 7 OPB Attenuation (db, max.) 6 5 4 4MHz OM2 OM3 3 2 Connecting hardware allowance 3.5dBkm -1 (corrected to 83nm) 1 2 4 6 8 1

1GBASE-SR/SW - Misconception 8 7 6 OPB Attenuation (db, max.) 5 4 3 2.59dB OM3 2 1 33m 82m Connecting hardware allowance 3m 3.5dBkm -1 (corrected to 83nm) 1 2 3 4 5 OM1 62,5/125 OM2 5/125

1GBASE-SR/SW and OMx 8 7 6 1GBASE-SR/SW OPB 5 Attenuation (db, max.) 4 3 Connecting hardware allowance OM3 3.5dBkm -1 (corrected to 83nm) 2 1 1 2 3 4 5 OM1 62,5/125 OM2 5/125

1GBASE-SR/SW and OMx 8 7 6 1GBASE-SR/SW OPB Attenuation (db, max.) 5 4,75dB = 9 m,75db = 44 m 3 2 OM3 3.5dBkm -1 (corrected to 83nm) 1 1 2 3 4 5 OM1 62,5/125 OM2 5/125

Statistical Modelling

The Impact of Multiple Connections - I Forecast: One Connection 1, Trials Frequency Chart Outliers.228 228.171 171.114.57 1, Trials Frequency Chart Outliers.163 114 Forecast: Two Connections 57 163..122. 1.88 3.75 5.63 7.5 122.2 <99.8%<.75.82.41. 1, Trials Frequency Chart Outliers.117.88 87.75. 1.88 3.75 5.63 7.5 81.5 Forecast: Four Connections 4.75 117.59 58.5.5<1%<1.35.29 29.25.. 1.88 3.75 5.63 7.5.25<1%<2.18

The Impact of Multiple Connections - II Forecast: Six Connections 1, Trials Frequency Chart Outliers.17.8.54 17 Forecast: Eight Connections 8.25 1, Trials Frequency Chart Outliers.84 84 53.5.27.63 26.75 63..42 42. 1.88 3.75 5.63.21 7.5 21.48<1%<2.68. Forecast: Ten Connections 1, Trials Frequency Chart Outliers. 1.88 3.75 5.63 7.5.8 8.9<1%<3.48.6 6.4 4.2 2.. 1.23<1%<3.83 1.88 3.75 5.63 7.5

Average Attenuation and Spread.8 Worst case average.6 attenuation per connection.4 (db).2 2 4 6 8 1 No. of connections 8 7.75dB per connection Connecting hardware attenuation (db) 6 5 4 3 2 1 1 2 3 4 5 6 7 8 9 1 No. of connections

1BASE-SX and OM2 7 6 5 4 3 2 1 2 4 6 8 1 No. of connections Attenuation model Bandwidth model - worst case Bandwidth model - reality

1GBASE-SR/SW: OM1, OM2 and OM3 5 4 3 2 1 2 4 6 8 1 No. of connections OM1 62.5/125 12 1 8 6 4 2 2 4 6 8 1 OM2 5/125 5 4 3 2 1 2 4 6 8 1 No. of connections OM3 No. of connections Attenuation model Bandwidth model - worst case Bandwidth model - reality

Data Centre Cabling Standards PREMISES CABLG DA CENTRE CABLG TO CP FD BD CD ISO/IEC 1181 BS EN 5173-1 Telecommunications Outlet Consolidation Point Floor Distributor Building Distributor Campus Distributor pren 5173-5 External Network Interface Main Distributor Zone Distributor Local Distribution Point Equipment Outlet External networks ENI MD ZD LDP EO TO TO TO TO TO ENI Horizontal cabling CP Network access cabling Building backbone cabling FD FD MD Main distribution cabling BD ZD ZD Campus backbone cabling CD LDP Zone distribution cabling EO EO EO EO EO

EN 5173-5: 25? EN 5173-1 pren 5173-1 pren 5173-2 Information technology - Generic cabling systems - General requirements and office areas Information technology - Generic cabling systems - General requirements Information technology - Generic cabling systems - Office premises pren 5173-5 Information technology - Generic cabling systems - Data centres Annex C (informative) Channel insertion loss models for high bit rate, multimode, optical fibre applications