Quick Reference Guide

Similar documents
Quick Reference Guide

Quick Reference Guide

Weekly Timer. ON/OFF and cycle operations up to one week Two SPST-NO time limit contacts with manual override switches

PROGRAMMABLE DIGITAL TIMER ELIRO (33 Functions): V7DFTS3

No mark Time-limit SPDT (1c) A Time-limit DPDT (2c) B Time-limit SPDT (1c), Instantaneous SPDT (1c) S DIN W48 H48mm.

Solid-State Digital Counter H7AN

HAMBURG INDUSTRIES CO., LTD.

Timers GT3F. GT3F Series True Power OFF Delay Timers. Phone: Fax: Web: -

Electronic circuit breaker ESS30-Sxxx-DC24V

WHEN A PLC IS TOO MUCH, AND SPACE FOR

NEO TELE-TRONIX PVT. LTD. 6/7 Bijoygarh, Kolkata , Tel : ; Fax :

Analog Timer TTL Series

NT240 TIMER. PROGRAMMABLE TIMER INSTRUCTIONS MANUAL V20x G TIMER OUTPUTS INTRODUCTION SPECIFICATIONS AUXILIARY SUPPLY OUTPUT INSTALLATION TIMER INPUTS

Multi-function 11 pin Plug-in for use with 90 series sockets

Count - counters 5. Selection guide 5 XBK T81030U33E RC XBK RC XBK T60000U00M XBK T60000U11M XBK T80000U00M XBK T70000U00M 5/2

Electronic Circuit Breaker with reset input ESS20-1..

Datasheet. Electronic Circuit Protection ESX10-T

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

Electronic Circuit Breaker ESS20-0..

Multi-voltage Multi-function. BE: Off-delay with control signal BE: Off-delay with control signal CE: On- and off-delay with control signal

BATCHMATE 1500 Batch Control Computer Technical Bulletin

E N SHT-1 SHT-1/2 SHT-3 SHT-3/2

FX-CM. HQ Color Mark Sensor. Model Number Legend SALIENT FEATURES. Sensors. Proximity. Photoelectric. Sensors

NT240 TIMER. PROGRAMMABLE TIMER INSTRUCTIONS MANUAL V20x A INTRODUCTION TIMER OUTPUTS SPECIFICATIONS AUXILARY SUPPLY OUTPUT INSTALLATION TIMER INPUTS

ATS-I USER MANUAL. Tecnoelettra srl Dal Via Vioni Dimo, S.Rocco di Guastalla (RE)

Modular timers A

Section 11 Electronic Position Controls & Encoders

Solid-state Timer H3DS

Model # PCYFC-10kW-250A PCYFC-20kW-250A PowerCycle Battery Conditioner Operation Manual

Timers. GT3A Series Analog Timers. GT3A-1 GT3A-2 GT3A-3 GT3A-4,-5,-6 Operation Multi-mode Multi-mode with inputs (11 pins) Time Range

Flexible Counter Series in DIN size 24 x 48 mm

HPX-ET Series. Gang-mounted Distributed Remote Cluster Type Fiber Optic Photoelectric Sensors. Specifications. click

Electronic Circuit Protector ESX10-T

CompoNet Gateway Unit for CC-Link

Digital Temperature Controller

Programmable Digital Timer

83 Series - Modular timers 16 A. Features

MODEL 8080PR3 Released on 11th Mar 2013

ATS-01 Ver1.2 AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL

Compact Preset Counter

Indicator (4digit) (5digit) 8-pin plug counter

Overview per day of the programmed switching times 5 = Friday. Channel statuses / OFF

83 SERIES. 83 Series - Modular timers A. Features

Multi-voltage Multi-function. Wiring diagram (without control signal)

MODEL: KS. Plug-in Signal Conditioners K-UNIT

Technical Data Sheet. x1000. kwh R Y B

И М. 2 24VAC 50/60Hz, 24-48VDC VAC 50/60Hz

NPN PNP NPN PNP NPN PNP

Solid-state Twin Timer

AGASTAT E7000 Series, Nuclear Qualified Time Delay Relays

Instruction manual. art Installation manual

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters

TA Series. Analog And Non-Indicating Type, PID Control, Set Temperature By Dial. Features. Ordering Information TA S B 4 R P 4 C

Sense Command Control. Third Eye. Energy Saving Sensors Save Energy Today for a Better Tomorrow

RS232 CONTROLLER/MONITOR

27/04/2015

5 Channel Multifunctional PWM Controller. HomLiCon LCH5T. Technical Specifications

Bulletin 700-HX Multifunction Digital Timing Relay

Control Relays and Timers

Step relays 10 A SЕRIES. Lighting control in corridors (for hotels, offices and hospitals) Bedroom light control. Living room light control

Paperless Recorder PR20

SERVICE-MANUAL ROOM TEMPERATURE CONTROLLER NEA 230V / 24V. Construction Automotive Industry

AC Resonant Test Systems Tank Type Up to 150 kv

Operations Manual. Model NT11 & NT11-E. June 18 th 2002

VAC V AC/DC, +/-10%, 45-65Hz Hz VDC max 1W ; 24VAC 2.5VA, 48VAC 4.46VA ; 110VAC 1.76 VA ; 220VAC 2.53 VA

INSULATION / WITHSTANDING Test Instrument series 3153/3159/ST5520

SR25. SHIMADEN DIGITAL CONTROLLER Shimaden, Temperature and Humidity Control Specialists MICROPROCESSOR-BASED AUOT-TUNING PID CONTROLLER

Electronic Circuit Protector ESX10

Programmable Digital Timer

G7K. Latching Relay. Compact Mechanical Lock Latching Relays with Manual Buttons. Model Number Structure. Ordering Information

Contents. Time switches. Presentation 2 Offer overview 4 Choice table 6 Technical data and catalogue numbers 8


Rated time Time setting range Time division 1 week 00:00 a.m. to 11:59 p.m. 1 min

CMM System - Encapsulated Modules

ON-delay operation 8-pin round socket DPDT --- H3CA-8 H3CA-8 SPDT SPDT H3CA-8H H3CA-8H

EBDSPIR-AT-DD. RF ceiling PIR presence detector DALI / DSI dimming. Product Guide. Overview. Features

HPJSeries HPJ. Ultraminiature Photoelectric Sensors with Self-contained Amplifier

ALP-UDR Universal Detection Relay user-defined protection, automation, and monitoring

PLC-K506 Series FEATURES DESCRIPTION FEATURES

DIY KIT 141. Multi-Mode Timer

1. Features 2. Terms and Functions Program StEP: StEP temperature, CXX: StEP time, txx: Running time: Jump: Run: Hold: Stop: Power interrupt:

Analogue temperature controllers

NSD Safety Mat Controller Modules Both Modules are compliant to OSHA & ANSI Standards - EN ISO EN EN 81-1 EN NSD VDC

Limit Switches Selection Guide. SN61 04 SL C Head Styles (see table below) Contact Type. SP: Snap Action. SL: Slow Action

Technical Description. DCF77 Receiver-Module 4460

MID. Energy Management Energy Analyzer Type EM11 DIN. Product Description. How to order EM11 DIN AV8 1 X O1 PF. Type Selection EM11 DIN

Section. Timers. Selection Guide... G-2. Timing Diagrams Overview... G-4. W G RTE Series Analog Timers... G-8 Accessories... G-11 Dimensions...

Digital Panel Meter. Ordering Information. Subminiature Digital Panel Meter that Accepts DC Input. Accessories (Order Separately)

GT5Y Series ON Delay Timers. UL, c-ul Listed File No. E V AC, 3A 30V DC, 3A 220V AC, 0.8A 30V DC, 1.5A 660VA AC 90W DC 176VA AC 45W DC

K3P ENG.qxd 23/10/ Pagina 1

EIB/KNX Switch Actuators. User manual

38 Series - Relay interface modules A

38 Series - Relay interface modules A

MODEL: AS4V. Plug-in Signal Conditioners M-UNIT

Multifunctional counter tico 772/773/774

SMARTimer, digital timer 16 A

E-STOP relays, safety gate monitors

Self-powered Counter

Phase and neutral overcurrent protection

INSULATION / VOLTAGE WITHSTAND TEST INSTRUMENT SERIES

Transcription:

Combination Timer S1DC8M3 ELECTRONIC AUTOMATION (P) LTD P. B. # 6414, Yelahanka, Bangalore - 560064 Phones: 0091-080 - 8567561 / 8567562 Fax : 9180-8567129 E-mail : eaplindia@vsnl.com URL : www.eaplindia.com

Thank you for purchasing EAPL s Combination Timer. This instruction manual describes every aspect of installation, set-up, and operation of the Combination Timer. If you run into difficulties and need technical assistance, feel free to call our technical support at (080) 8567561 available between 9 AM 5:30PM IST or visit our web site at www.eaplindia.com. EAPL, an ISO 9001 company, leaders in Timer Technology Brings to you a new range of micro controller based programmable timers. High reliability, accuracy, compactness are some of the striking design features. Uncompromising quality with cost effectiveness has been the watchword at EAPL. For Customer Use Enter below the serial Number which is located on the timer cabinet. Retain this information for future reference. Model No: Serial No: Batch No: Date of Purchase: Purchase Point: A c c e s s o r i e s S1DC8M3-1 no. Quick reference guide Note: Please acknowledge that we reserve the right to make changes in product performance or specifications without prior notice. Also please note that we bear no responsibility for mistakes, misprints or omissions of the instruction manual Specifications.

S a l i e n t F e a t u r e s State of the art microcontroller design User friendly programming for On/Off time selection up to 99 hrs 59 mins. 7 segment display indication for channel & timing operation. Program & process value retention incase of power failure. External contacts for timing initiation & timing pause. O r d e r i n g I n f o r m a t i o n Model Function Source Voltage Time Range Output S1D-C8M3 Combination switching 110/240V AC/24 V DC 1 sec to 99hrs 59mins.59 sec Relay S p e c i a l F e a t u r e s HOLD: When the slide switch on the front panel is kept in the hold position, the Timing data is retained in case of power failure. Upon resumption of power the timing continues from the point where it has stopped. RESTART: When the slide switch is kept in the restart position, their timer resets in case of power failure and waits for start signal from beginning upon power resumption. EXTERNAL START: By shorting terminals S1 and S2 for minimum period of 150 milliseconds (potential free shorting) or by keeping S1 and S2 permanently shorted, the time sequence is initiated. SINGLE CYCLE OPERATION: By keeping the terminals C1 and C2 shorted (potential Free) on the front panel, the switching of output is executed for one Cycle and stops. CYCLIC OPERATION: By keeping the terminals C1 and C2 on the front panel opened, the switching of outputs keeps repeating after the end of each cycle. INHIBIT: By shorting terminals I1 and I2 (potential free) on the front panel, status of relays output (ON or OFF) is maintained irrespective of the program timing. By removing the short, the programmed timing continues and relay respond as per the preprogrammed timings. RESET: By shorting terminals R1 & R2 (potential free) on the front panel, and changing the RUN/PROG switch from RUN mode to PROG mode, the programmed setting resets and sets all programs to 00:00.

S p e c i f i c a t i o n s S1DC8M3(110/240 V AC) S1DC8M3(24 V DC) Operating Voltage Range - 15% to + 10% of rated - 10% to + 10% of rated voltage voltage Rated frequency 50Hz/60 Hz + 5% - Power consumption 20V A / 4W(for 240/110V AC) DC approx.8w(for 24 VDC) Time Range 1 sec to 99hrs 59mins. 59 sec for delay & ON Control output 8 `NO relay contacts rated for 5A@ 250V AC/28V DC Resistive load Start Signal Potential free closure for a minimum of 150msec. Reset Signal Potential free closure Setting Accuracy + 0.2% + 50msecs Repeat Accuracy + 0.2% + 50msecs. Recovery Time 2secs min Variation due to voltage change +1% max. + 50msecs Variation due to temp change +2% max. + 50msecs Variation due to frequency change +1% max. + 50msecs. - Ambient Temperature Operation: -10 degree C to + 55 degree C Storage : -25 degree C to + 80 degree C Humidity Max. 85% RH @ 40 degree C Electrical Life 10 5 Operations min. with full load Service Life 10 6 Operations min. under no load Insulation Resistance >100M ohm@500vdc a)2.5 KV AC,50HZ for 1 min(between current carrying &non current carrying parts) Dielectric Strength b)1.5 KV AC,50HZ for 1 min(between contacts and control circuit) c)1 KV AC, 50HZ for 1 min(between non continuous relay contacts) Connections Screw type terminals with self lifting clamps Dimensions 200 x 130 x 45 mm [W x H x D] Operating Instructions Potential free contacts should be used to short terminals C1 & C2,I1 & I2,R1 & R2, S1&S2.Applying power to these points will damage the timer permanently. Programming is not possible if terminals I1 & I2 are shorted.

F r o n t P a n e l Before starting to program the timer ensure that all the programs in the 64 combinations are made zero (Check in all Hrs: min, Min: sec and sec: sec are all made 00:00:00) before programming. Ensure R1-R2 is open before programming for new setting. 1 RELAY This button is used to select the required output to program the timing. 2 COMBINATION This button is used to choose the combination particular output (upto 8 combination can be selected for each output relay) 3 DLY/ON This button is used to select the delay time and ON time for each relay output as per requirement. 4 RANGE This buttons is used to select the desired time range (MIN/SEC OR HRS/MIN). 5, 6 ADV This button is used to increment the DLY/ON time. 7, 8 INDICATOR It displays the selected time range combination like HRS/MIN OR MIN/SEC.

9 DISPLAY It displays the functioning time. 10, INDICATOR It indicates relay ON. 11 & 12 INDICATORS It indicates the DLY time and ON time. 13 DISPLAYS It displays the program number. 14 DISPLAY It displays the relay number selected for programming. 15 HOLD/RESTART This is the slide switch to select the mode from HOLD or RESTART. 16 PROG/RUN This is the slide switch to select the mode from PROGRAM or RUN state. T e r m i n a l D e t a i l s A1, A2 : Power S1, S2 : External Start I1, I2 : Inhibit C1, C2 : Single Cycle or Cyclic Function Implementation Short: Single Cycle function Open: Cyclic function R1, R2 : Resets all preset timings to 00:00:00. RLY1 to RLY8 : Normally open relay output C o n n e c t i o n D i a g r a m

T i m i n g D i a g r a m Single Cycle Model Start Si l R1C1 R1C2 R1C3 R1C4 R1C5 R1C6 R1C7 R1C8 R2C1 R2C2 R2C3 R2C4 R2C5 R2C6 R2C7 R2C8 R3C1 R3C2 R3C3 R3C4 R3C5 R3C6 R3C7 R3C8 R4C1 R4C2 R4C3 R4C4 R4C5 R4C6 R4C7 R4C8 R5C1 R5C2 R5C3 R5C4 R5C5 R5C6 R5C7 R5C8 R6C1 R6C2 R6C3 R6C4 R6C5 R6C6 R6C7 R6C8 R7C1 R7C2 R7C3 R7C4 R7C5 R7C6 R7C7 R7C8 R8C1 R8C2 R8C3 R8C4 R8C5 R8C6 R8C7 R8C8 R1C1 to R1C8 - Relay 1 combination 1 to Relay1 combination 8 R2C1 to R2C8 - Relay 2 combination 1 to Relay2 combination 8 R3C1 to R3C8 - Relay 3 combination 1 to Relay3 combination 8 R4C1 to R4C8 - Relay 4 combination 1 to Relay4 combination 8 R5C1 to R5C8 - Relay 5 combination 1 to Relay5 combination 8 R6C1 to R6C8 - Relay 6 combination 1 to Relay6 combination 8 R7C1 to R7C8 - Relay 7 combination 1 to Relay7 combination 8 R8C1 to R8C8 - Relay 8 combination 1 to Relay8 combination 8 * In cyclic mode the above sequence will repeat till the timer is reset NOTE: The above timing diagram is only a illustration of the Sequences that can be programmed. all 64 combinations can be programmed. P r o g r a m m i n g t h e T i m e r Keep the PROG / RUN slide switch in the PROG position. Apply rated voltage across A1 and A2. Press "Relay" button to select desired relay output (Relay1 to Relay 8). Press "Combination" button to select the desired combination 1 to 8 for a particular relay output Relay 1 to 8 Press DLY / ON button so as to select the Delay time for selected combination. Press the RANGE button, to select the desired time range (Min Sec or Hrs. Min) for the selected combination. Press DLY/ON button again, so as to select ON time duration for the selected combination.

Repeat step 5 to select desired time range. Use ADVANCE button to increment the DLY / ON time. Repeat steps 2 to 6 to program other combination for Relay 1. After completing programming for Relay 1, repeat steps 2 to 7 to program other relays (2 to 8). I n i t i a t i n g a S e q u e n c e By shorting the S1 and S2 terminals on the front panel for a minimum period of 150 milliseconds, the timing is initiated. S1 and S2 can be kept permanently shorted to start the sequence. NOTE: Before starting the programming ensures HRS/MIN & MIN/SEC timings of all 64 combinations of 8 relays are made zero. R e s e t t h e p r o g r a m m e d s e t t i n g s Short R1-R2 and slide the Run/Prog switch from the run mode to program mode. All programs get reset to zero Remove R1-R2 and program for new settings.