C103-E056C. Shimadzu Infrared Microscope

Similar documents
SHIMADZU GENERAL RADIOGRAPHIC SYSTEM

Infrared Microscope AIM-9000 C103-E103B

Development and Applications of a Sample Compartment FTIR Microscope

Infrared Microscope. Dedicated AIMsolution Software. Hisato Fukuda. 1. Introduction. 2. Automatic Contaminant Recognition Function

Material analysis by infrared mapping: A case study using a multilayer

Spotlight 150 and 200 FT-IR Microscopy Systems

Vol. Validation of FTIR Systems AIM-9000 Infrared Microscope Infrared Microscope. Convenience of a Wide-View Camera

FT-IR.

Agilent 8700 LDIR Chemical Imaging System. Bringing Clarity and Unprecedented Speed to Chemical Imaging.

Agilent Cary 610/620 FTIR microscopes and imaging systems RESOLUTION FOR EVERY APPLICATION

Bruker Optics Inc. Bruker Hong Kong Ltd. Billerica, MA USA Phone +1 (978) Fax +1 (978)

Characteristics and Applications of Imaging Microscope FT-IR. Teo Wei Boon PerkinElmer Singapore

Diamond Analysis. Innovation with Integrity. Reliable identification and type determination by FTIR spectroscopy FTIR

Horiba Jobin-Yvon LabRam Raman Confocal Microscope (GERB 120)

Thermo Scientific Nicolet in10 FT-IR Microscope. Infrared microscopy. with confidence. intuitive innovative integrated

FTIR microscopy and imaging for failure analysis in electronics manufacturing

Fast Laser Raman Microscope RAMAN

Super High Vertical Resolution Non-Contact 3D Surface Profiler BW-S500/BW-D500 Series

Measurement of Microscopic Three-dimensional Profiles with High Accuracy and Simple Operation

C103-E076. IRAffinity-1. Shimadzu Fourier Transform Infrared Spectrophotometer

Fastest high definition Raman imaging. Fastest Laser Raman Microscope RAMAN

LUMOS. Innovation with Integrity. FTIR Microscopy made easy FTIR

Spectrum 400. FT-IR and FT-NIR Spectrometer. There is only one answer.

FTIR Microscopy and Imaging

Bringing Answers to the Surface

Installation and User Guide. FlexIR TM NIR Fiber Optic Accessory

Fourier Transform Infrared Spectrophotometer. IRTracer-100 C103-E091B

Fast Laser Raman Microscope RAMAN

MEASUREMENT APPLICATION GUIDE OUTER/INNER

Systematic Workflow via Intuitive GUI. Easy operation accomplishes your goals faster than ever.

Applications of Optics

Confocal NEXIV VMZ-K Series. CNC Video Measuring System CONFOCAL NEXIV. VMZ-K Series

SEIMITU WAVE AR1260. Allegro. Mobility LLC

Fourier Transform Infrared Spectrophotometer. IRAffinity-1 C103-E076D

Terahertz Spectroscopic/ Imaging Analysis Systems

Confocal NEXIV VMZ-K Series. CNC Video Measuring System CONFOCAL NEXIV. VMZ-K Series

Thermo Scientific SPECTRONIC 200

Thermo Scientific Nicolet in10 FT-IR Microscope

Thermo Scientific SPECTRONIC 200 Visible Spectrophotometer. The perfect tool. for routine measurements

C103-E061E. IRPrestige-21. Shimadzu Fourier Transform Infrared Spectrophotometer

Mercury Cadmium Telluride Detectors

nanovea.com PROFILOMETERS 3D Non Contact Metrology

Thermo Scientific SPECTRONIC 200 Education

Sintec Optronics Technology Pte Ltd 10 Bukit Batok Crescent #07-02 The Spire Singapore Tel: Fax:

Application Note AN M102. FTIR Microscopic Identification of Fibers

Advancing FT-IR Imaging Synchrotron IR Imaging in Your Lab. Dr. Mustafa Kansiz FTIR Microscopy & Imaging Product Manager

Thermo Scientific SPECTRONIC 200 Visible Spectrophotometer. The perfect. teaching instrument

Metal coatings analysis using the handheld Agilent 4100 ExoScan FTIR

C227-E013B. HMV-2 series. Shimadzu Micro Hardness Tester

NeoScope. Simple Operation to 40,000. Table Top SEM. Serving Advanced Technology

EE119 Introduction to Optical Engineering Spring 2003 Final Exam. Name:

CNC Video Measuring System NEXIV VMZ-K series. CNC Video Measuring System. Confocal Model

1/8 m GRATING MONOCHROMATOR

Agilent 4300 Handheld FTIR Spectrometer AT-SITE. IMMEDIATE RESULTS. TRUE NON-DESTRUCTIVE ANALYSIS.

High-Accuracy Surface Scanning Method

WHITE PAPER MINIATURIZED HYPERSPECTRAL CAMERA FOR THE INFRARED MOLECULAR FINGERPRINT REGION

Damage-free failure/defect analysis in electronics and semiconductor industries using micro-atr FTIR imaging

December Fourier Transform and Apodization ABC of the FTIR Measurement Methods: Liquid Membrane Method Question --- 9

Modular Fourier Transform Infra-Red Spectrometer (FT-IR) Solution

Guide to Operating the Bruker FT-IR Microscope I. Basic Spectrum Acquisition with Vertex 70

The operation manual of spotlight 300 IR microscope

Fourier Transform Infrared Spectrophotometer. IRAffinity-1S C103-E096

C101-E094B UV PharmaSpec. Shimadzu UV-VIS Spectrophotometer

Foreign Particulate Matter testing using the Morphologi G3

SUPPLEMENTAL MATERIAL

Nicolet Continuμm Infrared Microscope

Procedures for Performing Cryoelectron Microscopy on the FEI Sphera Microscope

FTIR Spectrophotometer

DeltaMyc. Fluorescence Lifetime Mapping Microscope. Affordable Fluorescence Lifetime Imaging Microscopy (FLIM)

LumaSpec 800S User Manual

The equipment used share any common features regardless of the! being measured. Electronic detection was not always available.

Instruction manual SUN-PM100L. SUN-PM100L Polishing Machine English

SPECTRAL SCANNER. Recycling

Resolution. Diffraction from apertures limits resolution. Rayleigh criterion θ Rayleigh = 1.22 λ/d 1 peak at 2 nd minimum. θ f D

GCMS-3 GONIOSPECTROPHOTOMETER SYSTEM

CHAPTER 9 POSITION SENSITIVE PHOTOMULTIPLIER TUBES

SCIENTIFIC INSTRUMENT NEWS. Introduction. Design of the FlexSEM 1000

Huvitz Digital Microscope HDS-5800

Technical Procedure for Infrared Spectroscopy

FT-IR IMAGING THAT'S CLEARLY MEASURABLY AMAZING. Spotlight 400 FT-IR and 400N FT-NIR Imaging Systems

Light Microscopy. Upon completion of this lecture, the student should be able to:

UVISEL. Spectroscopic Phase Modulated Ellipsometer. The Ideal Tool for Thin Film and Material Characterization

Design of pollution preventing system for camera window

Remote Controlled R/F System C506-E056D

Opto Devices Product Information LED

Data sheet for TDS 10XX system THz Time Domain Spectrometer TDS 10XX

Applications of Steady-state Multichannel Spectroscopy in the Visible and NIR Spectral Region

UV / VIS Spectrophotometer EMCLAB Instruments GmbH

SUSS MA/BA Gen4 Series COMPACT MASK ALIGNER PLATFORM FOR RESEARCH AND LOW-VOLUME PRODUCTION

Application Bulletin 240

Non-Radiometric Measurement. Innovative concept of on-line measurement

Fourier Transform Infrared Spectrophotometer. IRAffinity-1S C103-E096C

M517-E077A O P E R A T I O N G U I D E

INFRARED ANALYSIS OF SINGLE AND MULTILAYER FILMS IN THE PRODUCTION AREA

Beam Shaping and Simultaneous Exposure by Diffractive Optical Element in Laser Plastic Welding

Physics 431 Final Exam Examples (3:00-5:00 pm 12/16/2009) TIME ALLOTTED: 120 MINUTES Name: Signature:

Keysight Technologies Why Magnification is Irrelevant in Modern Scanning Electron Microscopes. Application Note

VMZ-K3040 CONFOCAL. Confocal Imaging & Metrology. CNC Video Measuring System. Specifications. Dimensional Diagram

LEOK-3 Optics Experiment kit

Georgia O'Keeffe. THE Alfred Stieglitz COLLECTION OBJECT RESEARCH Palladium print Alfred Stieglitz Collection. AIC accession number: 1949.

Transcription:

C103-E056C Shimadzu Infrared Microscope

Complete Control with AIMView Right on Target... This intelligent infrared microscope provides convenient control of stage movement, aperture setting and focusing, all from the PC screen. Supporting analysis using transmission, reflection as well as ATR methods, the AIM-8800 widens the range of application fields. With emphasis on sensitivity for basic performance of this infrared microscope, ease of operation was also a high design priority. The AIM-8800 Infrared Microscope advances one step further into the new generation. Auto Aperture Maximizes IR illumination on the sample spot. The aperture is motor-driven, and its size and angle are freely set using mouse operation alone. Simply set the aperture over the sample, and the sampling area is automatically positioned for maximum infrared intensity. The aperture size and angle are always maintained. Auto X-Y Stage Simplifies exact sample positioning. Up to 10 sample positions and 2 background positions can be placed into memory, and the stage can be moved in increments as small as 1µm for finely detailed mapping. Auto Focus True focus is only one mouse-click away! Arduous focusing is unnecessary. Just one click of the mouse automatically brings the image into focus. Auto Centering Sample viewing couldn t be easier! Double-clicking on any point in the visible observation screen will bring that spot to the center of the viewing area. (Note : AIMView is the register trade mark of the software used to control the AIM-8800 Shimadzu Infrared Microscope.) High Sensitivity, Maintenance-Free MCT Detector High sensitivity of course! A signal-to-noise ratio of 2600 to 1 is guaranteed in transmission measurement. The high-sensitivity glass dewar type MCT detector eliminates the need to re-evacuate every 1 to 2 years, as required with metallic dewar type MCT detectors. Abundant Options A variety of options are available, including an ATR objective, 32 objective, micromanipulator, mapping software, etc. ATR Objective ATR-8800M 2 3

Easy Operation with Link 2 View All operations for controlling the infrared microscope are performed on the PC screen. Sample Holder When mounting the sample stage to the Auto X-Y stage, clicking the position of the displayed opening automatically moves the Auto X-Y stage to the center of the sample stage opening. Link 3 Position Recording Up to 10 sample positions and 2 background positions can be placed into memory, and at the same time, the aperture size and angle are also recorded in memory. Link 1 Auto Centering Double-click on any point in the visible observation screen, and that location instantly moves to the center of the viewing area. Visible observation screen Auto X-Y stage Y-axis movement Measurement position is moved to right-hand screen Returns to recorded position Maximize display Aperture Setting screen Aperture Setting Click near corner to change the aperture angle. Operation is also possible from the AIM-8800 main unit controller. Auto X-Y stage X-axis movement Manual focus adjustment Aperture Setting Enter a number to set size Auto focus Visual mode - IR mode switching Transmission mode - reflection mode switching 4 5

Abundant accessories for wide range of applications Wide ranging applications possible with array of optional accessories for the AIM-8800 Infrared Microscope. For pretreatment of micro samples... The MMS-77D-IR Micromanipulator System excels. The Shimadzu MMS-77D-IR Micromanipulator System greatly facilitates pretreatment of micro samples. With this system installed on the AIM8800, sampling and measurement can be conducted without fear of sample loss or contamination, thereby greatly enhancing analysis reliability. MMS-77 Functions and Applications Micro Cutting Microscopic foreign materials are reliably isolated and cut out of high molecular weight polymer, plastics, films, magnetic tapes, paints, semiconductors, liquid crystals, thin film transistors, etc. Infrared Microscope with Mounted Micromanipulator System MMS-77 Foreign particle on sheet a Micro Pick-up Foreign materials from a few µm to a few hundred µm in size can be effectively isolated and picked up from the surfaces of semiconductors, liquid crystals, magnetic tape, filters, or from powders, etc. Micro Injection Microliter quantities of solvent or cleansers can be injected into a microscopic area, or aspirated. Ideal for testing cleansing or corrosion characteristics, or for removing microscopic particles from liquids. A 30µm width section is cut out to remove section including foreign particle (a). b) Biocut c) Cutout section b Cutout section c Particle adhering to IC chip Sampling of foreign particle on filter Note : The Manipulator Mounting Kit (Cat.No.206-70463-91) is required for mounting the MMS-77 on the AIM-8800. a b a b a) Foreign particle b) Metal needle a) Foreign particle b) Metal needle Spectrum of particle removed from filter determined to be ABS resin. 6

ATR Objective (slide-on type) A magnification of 15, incident angle of 30 and single refection are provided with the incorporated 3mm-diameter Ge semicircular prism. The slide-type prism permits switching between the usual observation and infrared measurement modes. The ATR objective can be effectively used to analyze foreign particles on substrates which do not reflect light easily, such as paper or plastic, and well as to perform surface analysis. (%T) 120 100 80 60 40 25 4000 2000 1000 700 The spectrum of the adhesives on a glass board Diamond Cell A This attachment is used to compress a micro sample into a thin film, which is then analyzed directly by trasmission with an infrared microscope. Applications include pharmaceuticals, rubber compounds, plastics and polymers. The A type cell is constructed using artificial diamond, while the B type cell is also available, using natural diamond. (%T) 100 90 80 70 60 50 40 30 25 4000 2000 1000 700 The spectrum of the single fiber of polyester Above: Diamond cell use Below: Diamond cell unused Micro Vice Holder This holds various types of samples for microscopy. Sample orientation can be selected, or samples can even be stretched while being analyzed. 7

AIM-MAP Mapping Software Mapping software allows dimensional analysis of points, lines and surfaces. Capture microscope images and Synthesize a large visual image The mapping software captures microscope images and synthesizes a large visual image to determine the mapping area. Set mapping parameters on the synthesized visual image Mapping parameters such as mapping area, Aperture setting, scan interval, and so on are set op on the synthesized visual image by a mouse. Easy microscope operation Functions to control the AIM-8800 and Mapping operation such as switching the Transmittance/Reflectance mode are short-cut by icons on the screen. Various mapping mode Random (multi^point), Line and Area mapping are available. Not only general Transmittance/Reflectance mapping but also ATR mapping are available (ATR Objective is an optional). Manipulation of mapped data Spectra and map based on specified functional group are calculated from obtained mapping data. The mapped data is displayed by 3-dimensional (bird's-eye view), Contour or Spectral overly mode. The mapping software captures microscope images and synthesizes a large visual image to determine the mapping area. Mapping parameters such as mapping area, Aperture setting, scan interval, and so on are set op on the synthesized visual image by a mouse. An area mapping data consists of 4 coordinates-scanned position (x, y), wavenumber and absorbance. Display functions and Data manipulation functions of AIM-MAP calculates peak height, peak area or ratio at scanned position. And AIM-MAP calculates maps based on specified functional group. Shown data is a map calculated by alkyl group (3050-2750cm-1). The mapped data is displayed by 3dimensional (bird's-eye view), Contour or Spectral overly mode. 8

Distribution analysis is also possible. Distribution analysis of additive in film Various types of additives are applied to materials to impart a variety of characteristics. To ensure uniform product quality, uniform mixing of additives is necessary. Even in general macro measurement, where distribution analysis has been difficult, the infrared microscope enables such analysis. Spectrum of Film Cross-section Plots of Additive Peak (1510~1470cm -1 ) Surface Analysis using ATR Mapping Analysis of chrome plated surface film on glass substrate Processes such as surface improvement and coating are used to impart various types of functionality to materials. Further, it is necessary to meticulously control the surface state of processed materials. By performing mapping in the ATR microscopy mode, the surface state of the sample can be viewed in detail. ATR microscopy and mapping were used to analyze the two mixed components, polyimide (PI) and polyamide acid (PAA), in the chrome plating surface film on a glass substrate. A map was obtained based on the ratio of the 1720cm -1 peak and 1600cm -1 peak, allowing verification of the PI distribution. Blue line : Polyimide infrared spectrum Red line : Polyamide acid infrared spectrum Polyimide Distribution Map Mapping Line Mapping Measure data on the line from start to end points. Mapped data is 3 dimensional data consisted of wavenumber, absorbance and position. Area Mapping Measure data in the rectangular area specified by start and end points. Mapped data is 4 dimensional data consisted of wavenumber, absorbance and x-/y-position. 9

Applications Analysis by ATR Microscopy and Mapping Measurement Analysis of foreign substance on paper using ATR microscopy Figure 1 shows a photographic enlargement of a foreign particle on paper. Using ATR microscopy, infrared spectral measurement was conducted for the particle as well as the paper substrate. The result is displayed in Figure 2. There is no peak associated with the paper on the infrared spectrum of the particle, illustrating how ATR microscopy provides a good infrared spectrum of the particle without any influence from the paper substrate. A peak of the amide1appears in the vicinity of 1650cm-1 and another of amide2at 1550cm-1, indicating that the foreign particle is a secondary amide compound. Figure 1 Photographic Enlargement of Foreign Particle on Paper Figure 2 Infrared Spectra of Particle (red) and Paper (green) Mapping Measurement of Flux Adhering to Electronic Component Figure 3 shows a photographic enlargement of a flux particle adhering to an electronic component. Reflectance mapping measurement was performed on 15µm intervals of the area including the flux particle. Figure 5 shows the acquired map data, and Figure 4 shows the spectral data, with the flux peak observed at 1697.2cm-1 (carbonyl group peak). The height in Figure 5 is proportional to the amount of the adhering substance containing the carbonyl group. The red color indicates that there is a large amount of contaminant present. Figure 3 Photographic Enlargement of Flux Particle on Electronic Component Figure 4 Infrared Spectrum of Flux Figure 5 Flux Map of Carbonyl Peak at 1697.2cm-1 10

Specifications Optics : 15 Cassegrain objective 15 Cassegrain condenser mirrors w / inlet for purging MCT detector : w / liquid nitrogen monitoring system Wavelength range : Type 1-5000 - 720cm -1 Type 2-5000 - 650cm -1 Signal-to-noise ratio * : Transmission mode, aperture size 50µm, 8cm -1, 60 scans 2600 : 1 or higher (Type 1), 2000 : 1 or higher (Type 2) * These are the guaranteed signal-to-noise values when connected to the Shimadzu Fourier Transform Infrared Spectrophotometer Electrically activated aperture XYθ directional drive. Setting of XY direction increments is 1µm over sample surface, and 1 increments in θ direction (numerical entry possible). Minimum setting value : 3µm Motor-driven X-Y sample stage Positioning range : X axis : 70mm; Y axis : 30mm Resolution : 1µm pitch Sample thickness : Reflection mode - < = 40mm Transmission mode - < = 10mm Operation control via main unit keyboard Measuring mode selection / XY stage operation (speed variable in 4 steps) / manual focusing / illumination control Control via PC Measuring mode selection / XY stage operation / auto centering / manual focusing / auto focusing / illumination control / aperture setting / aperture preview / measurement position and aperture setting recording (10 sample positions, 2 background positions) Ambient conditions : Ambient temperature : 15 C ~ 30 C Ambient humidity : 70% or less External dimensions, weight : W410mm D540mm H520mm, 36kg Power requirements : AC100 / 120 / 220 / 230 / 240V 125VA Options Ge prism ATR objective Diamond ATR objective (Spectra Tech) ZnSe ATR objective (Spectra Tech) Grazing angle objective (Spectra Tech) 32 objective (Spectra Tech, only for reflection mode) Visual objective lens (10, 20, 40, 100 ) Note : When connected to a PC type FTIR-8000 Series, the PC for operating the FTIR main unit is also used for operating the AIM-8800. When connected to a non-pc type FTIR-8000 Series, the PC must be purchased separately. 11

Registered SHIMADZU CORPORATION. International Marketing Division 3. Kanda-Nishikicho 1-chome, Chiyoda-ku, Tokyo 101-8448, Japan Phone: 81(3)3219-5641 Fax. 81(3)3219-5710 Cable Add.:SHIMADZU TOKYO SHIMADZU SCIENTIFIC INSTRUMENTS, INC. 7102 Riverwood Drive, Columbia, Maryland 21046, U.S.A. Phone: 1(410)381-1227 Fax. 1(410)381-1222 Toll Free: 1(800)477-1227 SHIMADZU DEUTSCHLAND GmbH Albert-Hahn-Strasse 6-10, D-47269 Duisburg, F.R. Germany Phone: 49(203)7687-0 Fax. 49(203)766625 SHIMADZU (ASIA PACIFIC) PTE LTD. 16 Science Park Drive #01-01 Singapore Science Park, Singapore 118227, Republic of Singapore Phone: 65-778 6280 Fax. 65-779 2935 SHIMADZU SCIENTIFIC INSTRUMENTS (OCEANIA) PTY. LTD. Units F, 10-16 South Street Rydalmere N.S.W. 2116, Australia Phone: 61(2)9684-4200 Fax. 61(2)9684-4055 SHIMADZU DO BRASIL COMERCIO LTDA. Rua Cenno Sbrighi, 25, Agua Branca, Sao Paulo, CEP 05036-010, BRAZIL Phone: (55)11-3611-1688 Fax. (55)11-3611-2209 SHIMADZU (HONG KONG) LIMITED Suite 1028 Ocean Center, Harbour City, Tsim Sha Tsui, Kowloon HONG KONG Phone: (852)2375-4979 Fax. (852)2199-7438 Overseas Offices Istanbul, Beijing, Shanghai, Guangzhou, Shenyang, Chengdu, Moscow URL http://www.shimadzu.com Printed in Japan 3295-11216-10A-IK