Electronic circuit protector REX12

Similar documents
REX12 Electronic Circuit Protector

REX12 Electronic Circuit Protector

Electronic circuit breaker ESS30-Sxxx-DC24V

Electronic Circuit Protector ESX10

Electronic Circuit Breaker ESS20-0..

Electronic Circuit Protector ESX10-T

Electronic Circuit Breaker with reset input ESS20-1..

Electronic Circuit Breaker ESS1 for System SVS1

Datasheet. Electronic Circuit Protection ESX10-T

Electronic Circuit Breaker ESS1 for System SVS1

Electronic Circuit Breaker ESS1 for System SVS1

PHOENIX CONTACT

PHOENIX CONTACT

PHOENIX CONTACT - 09/2009

Smart Power Relay E I...

Power distribution system SVS25

Power Distribution System SVS18

PowerPlex Compact Module PP-C-COM24

Switched mode power supply for DIN rail mounting type SMP23 DC24V/40A

Switched mode power supply for DIN rail mounting type SMP21 DC24V/10A

Type CP-S, CP-C & CP-A Switch mode

Power supply CP-E 24/20.0

Power supply CP-D 24/1.3

Power supply CP-D 24/4.2 Primary switch mode power supply

Power supply CP-E 24/2.5

Power supply CP-E 24/0.75

Power supply CP-E 24/2.5

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet

Power Distribution System SVS02

Power supply CP-D 12/2.1

Control module CP-A CM

27/04/2015

Control module CP-A CM

Solid State Remote Power Controller E

Power Distribution System SVS02

Power supply CP-T 24/20.0 Primary switch mode power supply

Power supply CP-T 24/10.0 Primary switch mode power supply

Power Electronics. POWERSWITCH Solid-State Contactor BF 9250, BH 9250

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

V2IM10AL10 Art.Nr.: V2IM10AL10P Art.Nr.: Control element. Tripping delay. Function selector. Status indication 24...

Power supply CP-T 48/20.0 Primary switch mode power supply

Power Distribution System SVS20

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

Power supply CP-T 24/40.0 Primary switch mode power supply

MINI-PS AC/24DC/1.3

Electronic timer CT-TGD.22

QUINT-PS-24DC/24DC/10

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

CP-T range Product group picture

Electronic timer CT-MVS.12 Multifunctional with 1 c/o (SPDT) contact

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts

VEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA

PHOENIX CONTACT - 05/2008. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

Power supply CP-T 48/5.0 Primary switch mode power supply

QUINT-PS/ 3AC/24DC/10

V2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC

CP-T range Benefits and advantages


Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

EMD-FL-C-10. Current Monitoring Relay. Data Sheet. Functions. Structure 08/2004

PHOENIX CONTACT - 06/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

MINI-PS AC/2X15DC/1

Thermistor motor protection relays

Electronic circuit protector ESX10-Sxxx-DC24V-1A-10A

QUINT-PS/ 1AC/24DC/20

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Switching power supplies CP range, Linear power supplies CP-L range. Content

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Three-phase monitoring relay CM-PFS

QUINT-PS/ 3AC/24DC/40

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

QUINT-PS AC/24DC/40

Type Nominal voltage (V) Code HSV V

120/240 Watt AC-DC Front End with PFC W Series Convert Select 120 Convert Select 240

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC

Current monitoring relays CM-SRS.M1 For single-phase AC/DC currents

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Zelio Control Measurement Relays

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

MINI MCR-SL-UI-I-LP-NC

CP-E range Benefits and advantages

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

Electronic timer CT-WBS.22 Impulse generating and flashing with 2 c/o (SPDT) contacts

Insulation monitoring relay CM-IWS.1 For unearthed AC, DC and mixed AC/DC systems up to U n = 250 V AC and 300 V DC

ABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks.

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

Primary switch mode power supplies Product group picture

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

No-wear isolation of potentials in terminal block design

s s s 3-60 s min min 3-60 min h h 3-60 h V AC, 50/60 Hz

AC/DC. Monitoring Technique. VARIMETER IMD Insulation monitor RN 5897/300

Three-phase monitoring relays

Electronic timer CT-SDD.22

ABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories

Transcription:

Description The new electronic overcurrent protection REX12 consists of the supply module EM12-T and the single or double channel electronic circuit protector REX12-T which allows modular side-by-side mounting. The modules with a width of only 12.5 mm feature push-in technology including press release buttons and allow time-saving and maintenance-free wiring without tools. The supply module is designed for DC 2 V and 0 A and accommodates max. 10 mm² with wire end ferrule as a plus (+) supply. On the load output side the circuit protector can be wired with 2.5 mm². The new generation of electronic overcurrent protection REX12 combines flexibility with a compact design. It is exactly tailored to the needs of machine and panel builders. And what is more: no additional accessories are required when connecting the individual components electrically and mechanically. This helps save time and money! Features l Combination of supply module and electronic circuit protector l Single and double channel selective load protection by means of electronic trip curve l No accessories required for connecting the components l Width per channel only 12.5 mm (1-channel) or 6.25 mm (2-channel) l Fixed current ratings from 1 A to 10 A l Integral fail-safe element, adjusted to current rating l Inrush capacity up to 20,000 µf l Manual ON/OFF/reset momentary switch l Clear status indication by means of LED and signal contact Si l Connection via push-in terminals including orange press release buttons Benefits l Saves cost no further accessories required l Saves time through innovative and flexible mounting and connection technology l Saves space with a width of only 12.5 mm for two channels l Provides flexibility through ease of mounting, disassembly and modular design Approvals and standards Approval authority Standard Rated voltage Current rating range UL UL 2367 DC 2 V 1 A 10 A UL UL 1310 DC 2 V 1 A, 2 A UL culus508listed DC 2 V 1 A 10 A Overview of ordering number codes Supply module circuit protectors: 1-channel circuit protectors: 2-channel EM12-T00-000-DC2V-0A EM12-T01-001-DC2V-0A REX12-TA1-107-DC2V-1A REX12-TA1-107-DC2V-2A REX12-TA1-107-DC2V-3A REX12-TA1-107-DC2V-A REX12-TA1-107-DC2V-6A REX12-TA1-107-DC2V-8A REX12-TA1-107-DC2V-10A REX12-TA2-107-DC2V-1A/1A REX12-TA2-107-DC2V-2A/2A REX12-TA2-107-DC2V-3A/3A REX12-TA2-107-DC2V-A/A REX12-TA2-107-DC2V-6A/6A Technical data (T amb = +23 C, U B = DC 2 V) REX12-TAx-xxx circuit protectors REX12-TA1-107-DC2V-xA 1-channel REX12-TA2-107-DC2V-xA/xA 2-channel Operating voltage U B DC 2 V (18...30 V) Closed-circuit current I 0 REX12-TA1 1-channel in ON condition typically 5 ma REX12-TA2 2-channel in ON condition typically 8 ma Reverse polarity protection yes Power failure buffering time up to 10 ms Current ratings I N fixed ratings: REX12-TA1 1 A, 2 A, 3 A, A, 6 A, 8 A, 10 A REX12-TA2 1 A/1 A, 2 A/2 A, 3 A/3 A, A/ A, 6 A/6 A Visual status indication green: load circuit connected by LED Load circuit Load output green/orange blinking: load current warning limit reached 80 % orange: overload or short circuit until disconnection red: OFF: - after disconnection due to overload or short circuit - after undervoltage release of operating voltage in ON condition with autoreset Device switched off by means of ON/OFF momentary switch or no operating voltage power MOSFET switching output (plus switching) Load current typically 0.8 x I N warning limit (I WLimit ) hysteresis typically 5 % Overload current typically I OL : I N x 1.05 t OL : 3s disconnection (I OL ) typically I OL : I N x 1.35 t OL : 0,5 s with trip times (t OL ) typically I OL : I N x 2.00 t OL : 0.1 s typically I OL : I N x 2.50 t OL : 0.012 s Short circuit typically at short circuti (I SC ) t SC : 0,002 s 1) trip time (t SC ) (see time/current characteristic) 1) depends on the power suplly Influence of ambient see temperature factor table temperature on overload disconnection and load current warning limit 1733 www.e-t-a.de 1

Technical data (T amb = +23 C, U B = DC 2 V) Fail-safe element I N : 1 A fail-safe I N : 1 A integral I N : 2 A fail-safe I N : 2 A blade fuse I N : 3 A fail-safe I N : 3.15 A adjusted to I N : A fail-safe I N : A related current rating I N I N : 6 A fail-safe I N : 6.3 A I N : 8 A fail-safe I N : 8 A I N : 10 A fail-safe I N : 10 A I N : 1 A/1 A fail-safe I N : 1 A/1 A I N : 2 A/2 A fail-safe I N : 2 A/2 A I N : 3 A/3 A fail-safe I N : 3,15 A/3,15 A I N : A/ A fail-safe I N : A/ A I N : 6 A/6 A fail-safe I N : 6.3 A/6.3 A Voltage drop in load circuit at I N and at I N 70 % between LINE+ and LOAD+ I N : 1 A typically 180 mv I N : 70 % typically 125 mv I N : 2 A typically 110 mv I N : 70 % typically 80 mv I N : 3 A typically 120 mv I N : 70 % typically 85 mv I N : A typically 115 mv I N : 70 % typically 80 mv I N : 6 A typically 170 mv I N : 70 % typically 110 mv I N : 8 A typically 160 mv I N : 70 % typically 105 mv I N : 10 A typically 180 mv I N : 70 % typically 120 mv Operating voltage OFF at typically U B < 16.0 V monitoring ON at typically U B > 17.5 V with regard to low voltage with automatic ON and OFF switching Switch-on delay - with power ON channel 1: typically 100 ms channel 2: typically 200 ms - when switching on via channel 1: typically 5 ms ON/OFF momentary channel 2: typically 100 ms switch or - after undervoltage channel 1: typically 5 ms channel 2: typically 5 ms Disconnection of - manually on the device with the load circuit ON/OFF momentary switch - after an overload / short circuit disconnection with storage (no automatic reset) - temporarily at undervoltage - at no operating voltage Switch-on of load circuit - momentary switch device can only be switched on ON/OFF when operating voltage is applied - applying the device starts up with the condition operating voltage last stored Reset function a blocked load output (blocked by overload / short circuit) can externally be reset by the ON/OFF momentary switch Leakage current in load typically < 1 ma circuit in OFF condition Inrush capacity up to 20,000 µf Free-wheeling diode external free-wheeling circuit at inductive load (rating according to load) Parallel connection of not allowed several load outputs Status output Status indication REX12-T minus switching signal output group signalling is implemented in connection with EM12-T supply module Terminal design LOAD+ Push-in terminal PT 2.5 0.1 mm 2...2.5 mm 2, flexible AWG26 AWG1 str Stripping length 8 mm...10 mm Dimensions (w x h x d) 12.5 x 98,5 x 80 mm Mass REX12-TA1-xxx 1-channel approx. 57 g REX12-TA2-xxx 2-channel approx. 58 g Technical data (T amb = +23 C, U B = DC 2 V) General data Housing material moulded Mounting symmetrical rail to EN 60715-35x7.5 Ambient temperature -25 C...+60 C (without condensation, cf. EN 6020-1) Storage temperature -0 C...+70 C Mounting temperature +5 C +60 C Humidity 96 hrs / 95 % RH 0 C to IEC 60068-2- 78-Cab, climate class 3K3 to EN 60721 Vibration 3 g test to IEC 60068-2-6, test Fc Degree of protection (IEC 60529, DIN VDE 070) IP30 EMC requirements noise emission EN 61000-6-3 (EMC directive, CE logo) susceptibility: EN 61000-6-2 Insulation co-ordination (IEC 6093) 0.5 kv / pollution degree 2 Dielectric strength max. DC 30 V (load circuit) Insulation resistance n/a, only electronic disconnection (OFF condition) Approvals CE logo, UL 2367, File # E30670, culus508listed, File E92388 Preferred types Preferred types Standard current ratings (A) REX12-TA1 2 6 10 2/2 / 6/6 REX12-TA1-107-DC2V- x x x x REX12-TA2 2 6 10 2/2 / 6/6 REX12-TA2-107-DC2V- x x x Ordering number code - REX12-T Type REX12 Electronic circuit protector with PT connection technology Mounting method T rail mounting Design A 1 load output terminal per channel, fixed current ratings xa or xa/xa Number of channels 1 1 channel 2 2 channels Version 1 without physical isolation Signal input 0 without signal input Signal output: 7 status output Operating voltage DC 2 V voltage rating DC 2 V Current ratings 1 A (only 1-channel) 2 A (only 1-channel) 3 A (only 1-channel) A (only 1-channel) 6 A (only 1-channel) 8 A (only 1-channel) 10 A (only 1-channel) 1 A/1 A (only 2-channel) 2 A/2 A (only 2-channel) 3 A/3 A (only 2-channel) A/ A (only 2-channel) 6 A/6 A (only 2-channel) REX12 - T A 1-1 0 7 - DC2V - 10 A example of 1-channel REX12 - T A 2-1 0 7 - DC2V - 6 A / 6 A example of 2-channel 2 www.e-t-a.de 1733

Dimensions with connection diagram: REX12-TA1-xxx and REX12-TA2-xxx circuit protectors 98,5 92 12,5 contact arm REX12- TA2-1xx REX12- TA1-1xx Label e.g. from Phoenix Contact ZBF-12 DC2V DC2V 80 7,5 G E R M A N Y xa Momentary switch for ON/OFF and reset with integral status indication xa 2.1 xa 2.1 2.2 LOAD + LOAD + 1-channel 2-channels installation area operating area snap-on socket for rail EN 60715-35x7,5 Time/current characteristic (T amb = +23 C, U B = DC 2 V) Preferred mounting postion REX12: horizontal trip time in seconds 1000 100 10 1 0.1 0.01 0.001 0.8 1 1.2 1. 1.6 1.8 2 2.2 2. 2.6 2.8 3 I SC...times rated current G E R M A N Y Temperature factor / continuous duty The time/current characteristic depends on the ambient temperature. In order to avoid premature trip, the rating of the circuit protector has to be multiplied with a temperature factor and has to be accounted for when mounted side-by-side (see chapter Technical Information). Temperature factor table: ambient temperature [ C] 0 10 23 0 50 60 temperature factor 1 1 1 0,95 0,90 0,85 Note: When mounted side-by-side, the devices can carry max. 80 % of their rated load or a different rating has to be selected (see chapter Technical Information). Note: With high temperatures, the load current warning threshold warn limit typically 0.8 x I N will be reduced in accordance with the temperature factor. 1733 www.e-t-a.de 3

Description EM12-T supply module Dimensions EM12-T01-xxx supply module The EM12-T supply module receives the DC 2 V supply voltage, e.g. from a switched mode power supply, and distributes it to the mounted circuit protectors via the integral connector arm of the REX12-T. The potential-free auxiliary contact in the EM12-T indicates any detected failures through the circuit protector, e.g. to the superordinate control unit (CPU). Technical data (T amb = +23 C, U B = DC 2 V) 12, EM12- T01-001 DC2V 0 A 98 91,5 G E R M A N Y Operating voltage U B DC 2 V (18...30 V) Operating current I B max. 0 A Reverse polarity protection yes Quiescent current I 0 typically 10 ma Potential-free auxiliary max. DC 30 V / 0.5 A change-over contact min. 10 V / 1 ma Group signalling Si auxiliary contact, make contact Contact: Si (13) / Si (1) 13 1 OV LINE +1 80 normal condition: auxiliary contact closed - when ON, load output connected - when OFF, load output disconnected fault condition: auxiliary contact open - after an overload or short circuit disconnection - after undervoltage release of operating voltage in ON condition with autoreset - at no operating voltage U B in supply module Insulation co-ordination 0.5 kv / pollution degree 2 Power failure buffering time up to 10 ms Terminal design LINE+ Push-in terminal PT 10 0.5 mm 2...10 mm 2, flexible AWG20 AWG8 str Stripping length 18 mm...10 mm Terminal design 0 V / Si 13 / Si 1 Push-in terminal PT 2.5 0.1 mm 2...2.5 mm 2, flexible AWG26 AWG1 str Stripping length 8 mm...10 mm Dimensions (w x h x d) 12.5 x 98 x 80 mm Mass approx. 52 g Number of circuit protectors to be mounted side-by-side to EM12 REX12-TA1-x or REX12-TA2-x max. 16 pcs Ordering number code EM12 Type EM12 supply module for REX, with PT connection technology Mounting method T rail mounting Version: communication, interface 00 without signal 01 analog signal Additional functionality 0 without Signal input: 0 without signal input Signal output: 0 without signal make contact 1 signal make contact Operating voltage DC 2 V voltage rating DC 2 V Current ratings 0 A EM12 - T 01-0 0 1 - DC 2 V - 0 A ordering example Label e.g. from Phoenix Contact ZBF-12 snap-on socket for rail EN 60715-35x7,5 Schematic diagram EM12-Txx-xxx with REX12-xx EM12-T00-000-DC2V-0A 0 V LINE+1 EM12-T EM12-T01-001-DC2V-0A 1 13 0 V LINE+1 EM12-T max. 16 pcs REX12-T LOAD+ 21 (22) max. 16 pcs REX12-T LOAD+ 21 (22) www.e-t-a.de 1733

Application example: REX mounting on or removing from symmetrical rail Connector arm can be closed Push REX towards rail Remove REX... from rail Mount REX... side-by-side with EM... Unlatch with srewdriver, tilt upwards and remove (connector arm can be closed) Latch on enclosure downwards Application example: REX... replacement or disassembly Open connector arm Open connector arm Pull out at right angles to the rail Unlatch with screwdriver Instructions for installation Mounting or actuation of the REX connector arm must only be effected at dead-voltage. For start-up the REX connector arm must be closed. 1733 www.e-t-a.de 5

Application example: EM12-T with REX12-TA1 and REX12-TA2 Application example: REX... Locked connector arms Application example: REX12(D)-T... distance between cable duct and connector arm 60 Connector arms can be locked with enclosure 80 15 GERMANY All dimensions without tolerances are for reference only. E-T-A reserves the right change specifications at any time in the interest of improved design, performance and cost effectiveness, the right to make changes in these specifications without notice is reserved. Product markings may not be exactly as the ordering codes. Errors and omissions excepted. 6 www.e-t-a.de 1733

Sager Electronics is an authorized distributor of E-T-A and the REX12-T Electronic Circuit Protection Solution. Contact a Sager sales representative at 1.800.SAGER.800 or customerservice@sager.com for price and availability. Sager Electronics, the authorized distributor for E-T-A 1.800.SAGER.800 www.sager.com