QuidoDuplex. Two-state signal over-ethernet transmission set based on I/O module Quido. 12. July 2017 w w w. p a p o u c h. c o m

Similar documents
QuidoDuplex RS. Set for bi-directional transmission of 4 or 8 two-state signals over RS485 or RS June 2011 w w w. p a p o u c h.

THT2. Intelligent sensor. Humidity measuring range: 0 to 100 % Temperature measuring range: 40 to +125 C. Dew point automatic calculation

RS232 to RS485 or RS422 line converter with isolation. >>> Distribucion: ER-Soft, S.A. Tel: <<<

Intelligent Temperature Sensor TQS3. Measuring range -55 C to +125 C. Communication via an RS485 link

Connecting two Phoenix Studio Audiocodecs through a point-to-point IP radio link operating in the 5 GHz band

NetPage Network Wireless Paging System (POCSAG) NP-14 Series. Operation Manual CCW

Connecting two Phoenix Studio Audiocodecs through a point-to-point IP radio link operating in the 5 GHz band

Connecting Mains Electrical Power

PB-400-CN. Datasheet. IndustryAmp PB-400-CN * Applies to Part Number: *This unit has a CobraNet interface installed

Quick Start Instructions EMV-INspektor V2

Shenzhen ATC Technology CO.,LTD ATC. A-1 Serial Remote I/O Module. User Manual. V1.13 Edit:2018/01/

Datasheet. Octadrive DSP-CN * Applies to Part Number: *This unit has a CobraNet interface installed

R5 RIC Quickstart R5 RIC. R5 RIC Quickstart CONTENTS. Saab TransponderTech AB. Appendices. Project designation. Document title

INSTALLATION MANUAL. Model: Smart Analyzer Manufacturer: Smart Impulse. Power meter with consumption breakdown by use 03/12/13

Data Acquisition Modules/ Distributed IO Modules

Connecting the Radio:

Four channel wireless switch controller SK108

A-MUX 32P DOCUMENTATION

P2P 2 YEAR PL-VDIO-05. Smartphone Connect IP VIDEO DOOR PHONE QUICK START GUIDE 7 VIDEO DOOR PHONE SYSTEM WITH SMARTPHONE CONNECT

Modular Metering System ModbusTCP Communications Manual

XLR PRO Radio Frequency (RF) Modem. Getting Started Guide

DESCRIPTION DOCUMENT FOR WIFI TWELVE INPUT TWELVE OUTPUT BOARD HARDWARE REVISION 0.1

Endurance R/C Wi-Fi Servo Controller 2 Instructions

Electrical devices may only be mounted and connected by electrically skilled persons.

SIMREX Corporation Your Trusted Wireless Solution Provider

WPE 48N USER MANUAL Version1.1

RF Wireless Serial Device Server

GFT1012 2/4 Channel Precise Slave Generator

JUMO Wtrans Receiver Universal Receiver for JUMO Wireless Measuring Probes

M2M i-link POINT-TO-MULTIPOINT INSTALLATION INSTRUCTIONS

Logosol AC/DC Intelligent Servo Drive for Coordinated Control LS-174WP

AW5800-SPEC USER S MANUAL

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

F2A3X Frequency to Analog Converter Module

Selection guide. Communication accessories. Communication accessory selection guide. Characteristics

TDS 10. (Euro)DOCSIS cable modem TDS 10 with extension modules. For remote meter monitoring and reading

AW900-SPEC USER S MANUAL

QUICK SETUP GUIDE: Firewire/mLAN MACINTOSH OSX Cubase AI4 / Studio Manager / Motif XS Editor / Mac OSX

Interface Genius Modem Instruction Manual v1.2.4

BusWorks 900EN Series Modbus TCP/IP 10/100M Industrial Ethernet I/O Modules

Datasheet. IndustryAmp PB-800-CN * Applies to Part Number: *This unit has a CobraNet interface installed

AI BOX 1. ASSEMBLY. A1 : Desk frame B1 : 2 holes for installing 2 M5x16 screws

Key Features. Base-line surveys for planning Construction site monitoring Road traffic noise monitoring

Analog Module D1-15P User Manual

WEC200 Wiegand to Ethernet

Installation guide. Activate. Install your Broadband. Install your Phone. Install your TV. 1 min. 30 mins

EY-EM 527: Remote I/O module, ecolink527

A6500-UM Universal Measurement Card

IN THIS GUIDE YOU WILL LEARN HOW TO CONNECT TO OPTUS NBN IN NO TIME

JUMO Wtrans E01. Measuring probe for humidity, temperature, and CO 2 with wireless data transmission. Brief description. Universal Wtrans receiver

MICROWAVE FREQUENCY SYNTHESIZER QP-FSPLL USER MANUAL

GFT1504 4/8/10 channel Delay Generator

VBRC 5. Radio Communicator. Installer Manual

Photoelectrics Amplifier, µ-processor Controlled Type PAM, 2-10 Inputs/2-10 Transistor Outputs

ADA User manual ADA RS-232 to RS-485 / RS-422 Converter

RC-WIFI CONTROLLER USER MANUAL

MICROPROCESSOR-BASED METERING EQUIPMENT SECTION 16901C PART 2

WEB I/O. Wireless On/Off Control USER MANUAL

Applications. Operating Modes. Description. Part Number Description Package. Many to one. One to one Broadcast One to many

OVEN INDUSTRIES, INC. Model 5C7-362

The wireless alternative to expensive cabling...

LASER. Analog Laser Displacement Transducer. LAM Series. Key-Features: Content:

DMX-CONTROL OF MOTORISED DIMMER SHUTTER AND LAMP IGNITION

NTS-pico. Miniature NTP Time Server for Small Networks

maxon document number:

INSTALLATION AND OPERATION MANUAL

Wind Turbine Analysis System - Type 3652 MKII & MKIII

ARP Radio Modem & Router Datasheet

LocoRCD2 Manual. HDM20C For scale Z, N, TT and HO. HDM20E For scale O, 1 and G

Remote Site Monitoring

MultiNet. Instruction Manual. Digital Energy Multilin. Serial to Ethernet Converter. Manual P/N: A2 Copyright 2009 GE Multilin

ivu Plus Quick Start Guide P/N rev. A -- 10/8/2010

SpeedTouch 190. Setup and User s Guide. SIP Gateway. Release R1.0

USB Multifunction Arbitrary Waveform Generator AWG2300. User Guide

USER MANUAL SATEL i-link I/O-converter Version 1.6

The wireless alternative to expensive cabling...

Z-10-D-IN. RS485 Modbus Module 10 Digital Inputs

Engineering Guideline. pac-carriers Type for Yokogawa Centum VP

IP1 Datasheet PWM OUTPUT WITH SINGLE CHANNEL ADC MODULE FEATURES DESCRIPTION CONNECTOR DETAILS

PROMUX Distributed MODBUS I/O Modules Catalog and Design Guide

TVGuider astronomical telescope autoguider

GEONICA, S.A. - Alejandro Rodríguez, nº Madrid - Spain Tel Fax

AW2400iTR USER S MANUAL 2.4 GHz Indoor Wireless Ethernet Radio

Model 805 PWM Proportional Valve / Solenoid Driver with Peak and Hold Control Modes

IN THIS GUIDE YOU WILL LEARN HOW TO CONNECT TO OPTUS NBN IN NO TIME

Acceleration sensors With relay output for limit monitoring Analog / CANopen

Hytera. PD41X Patrol Management System. Installation and Configuration Guide

DESCRIPTION DOCUMENT FOR WIFI/BT QUAD RELAY BOARD HARDWARE REVISION 0.1

B850 Boiler House Energy Monitor

GPSR116 Quick Start Guide

Compact IP20 Multiprotocol Ethernet I/O Station 4 Digital PNP Inputs and 4 Configurable Digital PNP Channels FEN20-4DIP-4DXP-DIN

Emergency PHM Series. Emergency PowerHUBB Node - Master/Control/Tunable White. Dimensional Data. Ordering Information (Example: PHM4PC EM)

IN THIS GUIDE YOU WILL LEARN HOW TO CONNECT TO THE NBN IN NO TIME

Instruction Manual REMOTE CONTROL BOX OM3500 A. OM POWER, s. r. o Báč 126 SLOVAKIA

Galil Motion Control. DMC 3x01x. Datasheet

EUROPEAN RADIO RIPPLE CONTROL

SCADA and Telemetry Solutions. SCADALink IO900. Modular Wireless I/O System. User Manual Version V1.3 for SCADALink IO900 BENTEK SYSTEMS LTD

Home Automation, Inc. Omnistat2. RC-1000 and RC-2000 Communicating Thermostat. Serial Protocol Description

Trip amplifier, 1 channel

PROMUX Distributed MODBUS I/O Modules Catalog and Design Guide

Transcription:

Two-state signal over-ethernet transmission set based on I/O module Quido 12. July 2017 w w w. p a p o u c h. c o m

Q uidoduplex Datasheet Created: 3/16/2006 Last update: 7/12/2017 1:28 PM Number of pages: 16 2017 Address: Strasnicka 3164 102 00 Prague 10 Czech Republic Tel: +420 267 314 267 +420 267 314 268 +420 602 379 954 Fax: +420 267 314 269 Internet: E-mail: info@papouch.com Page 2

QuidoDuplex CONTENT Basic information... 4 Description... 4 Application... 4 Block Connection... 4 First Connection... 5 Operation... 8 Simple Indication of Lost Connection... 8 Input and Output terminal connection... 9 Inputs... 9 Outputs... 10 Technical parameters... 11 Summary... 11 Principle of input status change evaluation... 12 Available designs... 13 Available Accessories... 14 Fig. 1 QuidoDuplex 4 Page 3

BASIC INFORMATION D e s c r i p t i o n QuidoDuplex enables the synchronisation of two I/O modules connected to the Ethernet. Activating the input of one module switches on the relay in the second module and vice versa. Thus it is possible to transmit the status of contacts or other two-stage signals over the Ethernet. See the example shown in the figure on the front page of this document (it shows the transmission of four signals). App l i c a t i o n Remote control using the two-state signals over the Ethernet. Using the existing Ethernet network to transmit control signal without the necessity to install any additional data conductors. B l o c k C o n n e c t i o n The status of Input 1 in Module A is transmitted to Output 1 in Module B and vice versa. Thus the status of all signals is transmitted bi-directionally. Fig. 2 Block Connection Page 4

QuidoDuplex F i r s t C o n n e c t i o n 1) Connect the input and output terminals. The description of input and output terminal connection options can be found in chapter Input and Output Terminal Connection on page 8. 2) Connect QuidoDuplex to a computer network or to a PC. If you connect QuidoDuplex to a computer network, use a standard (untwisted) cable and interconnect the ETH connector on Quido with the Ethernet connector on the HUB or switch. If you wish to connect Quido directly to a PC, use a patch cable. 3) Connect power supply to terminals PWR (+) and GND (-). 1 4) Set Quido IP address and other parameters over the WEB interface (Network/IP Configuration). The default IP address is 192.168.1.254. 2 3 Fig. 3 WEB interface 1 The power supply input terminal is protected against the reversal of polarity. 2 If your network contains a range of addresses which differs from the address of QuidoDuplex, the IP address needs to be set: Connect Quido directly to a PC via the patch cable. Then set the same network for the PC as used by Quido, e.g. within the range of 192.168.1.xxx and net mask to 255.255.255.0. Then it will be possible to use the WEB browser to connect to Quido and set its new network parameters. 3 After entering the IP address and connecting to the device a dialog box for entering a name and password shows up. No default password has been set. Thus you can leave both fields empty and click OK. Page 5

5) Set the following parameters of Quido (they are also listed on the main WEB page of QuidoDuplex): 6) Set the serial line speed to 115200Bd in Serial Settings > Port Settings > Line Speed. Fig. 4 Setting the speed of 115 200 Bd 7) Select TCP protocol in Connection/Connect Protocol. Page 6

QuidoDuplex 8) Select Yes in Connection/Connect Mode/Passive Connection/Accept Incoming. Fig. 5 Setting communication over Ethernet 9) Select With Any Character in Connection/Connect Mode/Active Connection/Active Connect. 10) Connection/Connect Mode/Endpoint Configuration/Remote Port set 10001. 11) In Connection/Connect Mode/Endpoint Configuration/Remote Host enter the IP address of the remote QuidoDuplex. 12) Set the remote QuidoDuplex accordingly. 13) The setup of both modules is now finished. Page 7

O p e r a t i o n After being switched on, both modules synchronize within ten seconds, if there are no troubles with the Ethernet connection. If there are no troubles with the Ethernet connection, both modules synchronize within ten seconds upon start-up. In case there is a failure of Ethernet connection for longer than 5 seconds, both modules open the output relay. If the status of any input is changed, a command is sent immediately to the other module to change the status of the corresponding relay (for Input 1 to Relay 1, for Input 2 to Relay 2, etc.). The time necessary for the output to change the status depends entirely on the speed of the information transmission over the Ethernet. The response of the module is immediate without any delay. S i m p l e I n d i c a t i o n o f L o s t C o n n e c t i o n The established connection can be tested in a simple way in case that the system does not use all communication signals. Make a permanent activation of one of the unused inputs in one module. This causes permanent activation of one relay in the second module. Its contacts, which are open as long as communication is carried out, can be connected to a light bulb, a buzzer etc. If the connection is lost then, the module disconnects all contacts after five seconds including the relay connected to the indication of lost connection. Thus the indication bulb switches on, the buzzer sounds etc. Page 8

QuidoDuplex INPUT AND OUTPUT TERMINAL CONNECTION I n p u t s The inputs can be controlled by connected voltage or a contact. Fig. 6 Input terminal box of QuidoDuplex with four signals Each input is connected as shown in Fig. 8. IGND grounding is galvanically isolated from the device GND. Contact Input Fig. 7 input circuit connection Contact shall be connected as shown in Fig. 9 contact voltage is provided by an external power source here. Fig. 8 Contact input Page 9

Voltage Input Voltage input connection is shown in the following figure. O u t p u t s Fig. 9 Voltage input Each output is equipped with a relay with make-and-break contact. The contact is illustrated on the board next to the terminals. NO is the make contact, NC is the break contact. Fig. 10 Make-brake contacts of output relays in QuidoDuplex with four signals Page 10

QuidoDuplex TECHNICAL PARAMETERS S u m m a r y Inputs: No of digital inputs... 4 or 8 (according to the version) Input type... for the connection of voltage or switching contact Galvanic separation... optical Response to change in status... 2 to 250 ms (for sampling see Fig. 11) 4 VERSION I. 5 : Input voltage for state 1... 4.5 10 V Input voltage for state 0... 0 2.5 V Input current at 5 V... typically 3.2 ma Input current at 9 V... typically 8.9 ma Maximum input voltage... 10.0 V VERSION II. 5 : Input voltage for state 1... 7 28 V Input voltage for state 0... 0 3 V Input current at 12 V... typically 3.5 ma Input current at 24 V... typically 7.8 ma Maximum input voltage... 28 V Outputs: No of digital outputs... 4 or 8 (according to the version) Type... make-and-break relay contact Maximum switching voltage... AC voltage: 60 V, DC voltage 85 V Maximum switched current... 5 A Protective varistor... U AC = 60 V; E MAX = 5 J; C = 0,64 nf Control interface: Type... 10/100 Ethernet Connector... RJ45 Internal communication speed... 115 200 Bd (stable) 4 The default value of sampling is set to 10 ms. 5 By default, Quido comes in version II. (inputs for voltage of 7 to 28 V). Page 11

Other parameters Four-signal version: Power supply... 8 to 30 V DC, protection against polarity reversal Current consumption... max. 280 ma at 12 V (all relays activated) Input and output connector... Wago 236 terminal box, conductor cross-section 2.5 mm max Operating temperature... 20 C to +60 C Size... 97 mm 87 mm 20 mm Weight... 95 g Other parameters Eight-signal version: Power supply... 8 to 30 V DC, protection against polarity reversal Current consumption... max. 385 ma at 12 V (all relays activated) Input and output connector... Wago 236 terminal box, conductor cross-section 2.5 mm max Operating temperature... 20 C to +60 C Size... 138 mm 96 mm 20 mm Weight... 180 g P r i n c i p l e o f i n p u t s t a t u s c h a n g e e v a l u a t i o n Fig. 11 Principle of input status change evaluation The value of the input is sampled in the interval of 10 ms 6. The input status is considered valid if the same value is read in two consecutive samples. 6 If this sampling interval is not suitable for your application, we will be happy to change it. Page 12

QuidoDuplex A v a i l a b l e d e s i g n s Assembly: No holder (standard design) With DIN rail holder Fig. 12 Example of standard design (picture shows module with four signals) Cover: Fig. 13 example of design with DIN rail holder and plexi cover (picture shows module with four signals) No cover (standard design) With plexi cover (see Fig. 15) Input voltage options: 5 V 12 V (standard version) 24 V Examples of options which can be added upon request: More modules connected in synchronous operation. Change of input voltage. and other customised functions to suit your application. Do not hesitate to contact us in case of any other requirements concerning the design and functions of the QuidoDuplex module. Page 13

A v a i l a b l e A c c e s s o r i e s Switched power supply unit 12V Switched power supply unit 230 V/12 V DC, socket adapter design. Power supply unit 230 V/12 V for DIN rail Linear power supply unit 230 V/12 V DC for DIN rail. Ethernet cable Cable for connection to PC network. Lever for Wago 236 terminals A tool for easy control of Wago 236 terminals. Fig. 14 lever for Wago 236 terminals Page 14

QuidoDuplex Page 15

Data transmission in industry, line and protocol conversions, RS232/485/422/USB/Ethernet/GPRS/ WiFi, measurement modules, intelligent temperature sensors, I/O modules, and custommade electronic applications. Address: Strasnicka 3164 102 00 Prague 10 Czech Republic Tel: +420 267 314 267 +420 267 314 268 +420 602 379 954 Fax: +420 267 314 269 Internet: E-mail: info@papouch.com w w w. p a p o u c h. c o m