Osmolarity System USER MANUAL FOR QUANTITATIVE MEASUREMENT OF OSMOLARITY OF OCULAR TISSUES. osdcare.com

Similar documents
BIODEX MULTI- JOINT SYSTEM

English

Powered Traction Unit OPERATION MANUAL

Guidance and Declaration - Electromagnetic Compatibility (EMC) for the Delfi PTS ii Portable Tourniquet System

HeRO duet

General Safety/EMC and Electrical Information for i-limb ultra and i-limb digits

Biological Safety. Electromagnetic Compatibility (EMC) Observe the following precautions related to biological safety.

D C 01/2019 3

Electromagnetic compatibility Guidance and manufacturer s declaration DIN EN :2007 (IEC :2007)

TH008F Multi-function Infrared Forehead Thermometer

User Instruction Computer Assisted Local Analgesia. 337 Marion, Le Gardeur QC, Canada, J5Z 4W8

Nursing Beds with Dewert drive system

USER MANUAL MHS-2500I. Please take time to read these instructions before starting to use the scale. Version /17

Operating Manual Infrared thermometer

Technical Specifications Micromedical VisualEyes 505 by Interacoustics

INTRODUCTION. 4 SAFETY INSTRUCTIONS. 5 ABOUT THIS DEVICE. 6 FIRST OPERATION. 7 THE DISPLAY. 8 ATTACHING THE WRIST SLEEVE. 9 CORRECT MEASUREMENT.

Rolyan Splint Pan OPERATION MANUAL. Item # Small Item # Large

(c) Medisave UK. Notice. Edition 1. i-pad Operator s Manual

PHYSIOFLOW Q-LINK TM

DENTAL X-RAY OPERATOR'S INSTRUCTIONS. (for USA) Wall Mount Type...WK

OtoRead - Technical Specifications Page 0. Technical Specifications. OtoRead D A 2017/06

: 0089 GTIN

MedRx Avant Polar HIT AH-I-MPHITS-5 Effective 11/07/11

Not for print. Microphone Test Device with SONNET MTD Adapter. User Manual. Cochlear Implants NOT FOR PRINT

VN415/VO425 Specifications

M-400 M-410 M-420 M-430

USER MANUAL M-200. Please take time to read these instructions before starting to use the scale. Version /06

SAVI SCOUT Surgical Guidance System. Console Operation Manual

H2 Check Operating Manual

#

Technical Data. Electrocardiograph ECG-1250K TD.ECG1250_L. This technical data may be revised or replaced by Nihon Kohden at any time without notice.

GTIN:

The following symbol indicates that the device is MR-unsafe:

INSTALLATION MANUAL AVANT HIT+ Hearing Instrument Test Chamber.

L NKTEMP. Non-contact. Infrared Thermometer. User Manual LMP001

SJM MRI Activator. Handheld Device. User's Manual. Model EX4000

WRIST BLOOD PRESSURE MONITOR

Central Blood Pressure Meter Model cbp301. Operating Manual

SPAC265-8W. AC-DC power supply module. Features. Description. Applications

The following languages can be found on our website: French. German. Spanish. Italian. Swedish. Portuguese. Russian. Dutch.

BodyclockStimplusManual.qx8_Layout 1 17/08/ :53 Page 1. Body Clock Stimplus. Instructions for use

DIGITAL BLUETOOTH THEROMETER PBT

OPERATOR S MANUAL AN APPLIED DIGITAL COMPANY

ENG en. Operating instructions. Iris Magneton MF Wellness therapy

Transcutaneous Electrical Nerve Stimulator

INSTRUCTIONS FOR YOUR NEW PLASMAFLOW. Vascular Therapy System (Compressible Limb Sleeve Device)

Connevans.info. DeafEquipment.co.uk. This product may be purchased from Connevans Limited secure online store at

#0086.

Operator s Manual External Remote Controller (ERC)

Exergen TAT 5000S RS232 TTL Supplemental Instructions for Use

Welch Allyn Home Scale (T- RPM-SCALE100)

User Manual. Before Using Your WiTouch Pro Device

HD STETH TM Quick Start User Guide

ENGLISH. Important safety information Read this important information carefully before you use the device and save it for future reference.

User Manual. Glass Body Fat Analyzer LS203-B. version:1.0

Ceiling Model Ceiling Model for LEDview Plus and Heliodent Plus. Installation Requirements. New as of: English

OPERATOR'S INSTRUCTIONS DX-073 DENTAL X-RAY

2015 Koninklijke Philips N.V. All rights reserved Philips Consumer Lifestyle BV Tussendiepen 4, 9206AD Drachten, Netherlands

Rotating Anode X-Ray Tube Housing Assembly. General Data

Read and be familiar with this manual before operating or servicing this device. To ensure operator, technician, and patient safety, use only as

ibed Locator Model 5212

Pain Management System

JPD-FR302. User Manual. Infrared Thermometer

AUTOMATIC BLOOD PRESSURE MONITOR (Arm Cuff Type) INSTRUCTION MANUAL

USER S MANUAL Volk Pictor Plus Fluorescein Angiography (FA) Module For Use with: Volk Pictor Plus

Operator s Manual. PP016 Passive Probe

POCKET AIR. Portable Nebulizer. Instruction Manual MBPN002 / MB / MB05006

Operator s Manual. PP022 Passive Probe

User Manual. Use, Maintenance and Service of the. Sinuscan 301

Draft. User s Manual. Transmitter Model EX1150

`bob`=p=^åèìáëáíáçå=råáí

User s Manual. Miniature Passive Probe. IM EN 3rd Edition

OPERATOR'S INSTRUCTIONS DENTAL X-RAY MODEL 096

CardioMessenger II-S Transmitter for BIOTRONIK Home Monitoring. Technical Manual

IEC Second Edition

Multi-Control Panel for built-in system. Multi Pad for NLX / imd OPERATION MANUAL OM-E0538E 001

AC/DC CLAMP METER USER S MANUAL

OPERATOR S INSTRUCTIONS (for USA & Canada)

Philips body analysis scale with Bluetooth Smart DL8781, DL8780 EN-US

TV Transmitter. User Guide Master

Operator s Manual. PP017 and PP018 Passive Probes

Relief. At Last. User Manual For an effective treatment, read the entire User Manual before using Kyrobak.

Wireless TENS Pain Reliever. WT1 Series

TM Machine WetAlert TM Wireless Wetness Detector In-center User s Guide

The Symbol means that the Vet-Tech (200, 250 or 300HF) system intentionally applies some radioelectric energy for diagnostic or treatment purposes.

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

Product Name: COMPER SMART DOPPLER FETAL MONITOR. Product Model: DFMX

MDC4500-4B Amplifier/Combiner Data Sheet & User Manual. February Rev 0.95

Body Clock Stimplus Pro

MODEL PCU Pressure Control Unit with Patient Isolation. Instructions for Use (IFU) Sensors.Systems.Solutions.

Model 5100F. Advanced Test Equipment Rentals ATEC (2832) OWNER S MANUAL RF POWER AMPLIFIER

`bob`=p=^åèìáëáíáçå=råáí=bma

By Paul Aylett at 12:08 pm, Apr 13, 2016

CONTACTLESS THERMOMETER Thermo Checker

This manual is valid for the TM. In TENSity 5000 TENS Stimulator. This user manual is published by Current Solutions, LLC

Transmitter Model EX1100, EX1100W. User's Manual

Standard Electric Console REF Instruction for Use

DM-45 Digital Multimeter

This product may malfunction due to electromagnetic waves caused by portable

EMC Test Report. Report Number: M030826

Transcription:

Osmolarity System FOR QUANTITATIVE MEASUREMENT OF OSMOLARITY OF OCULAR TISSUES USER MANUAL osdcare.com

I-PEN User Guide I-PEN User Guide TABLE OF CONTENTS I-PEN I-PEN is a trademark of I-MED Pharma Inc. Other registered trademark or trademarks are the property of their respective owners. CONTACT INFORMATION Customer satisfaction is an I-MED Pharma Inc. priority. To help us in providing you with the best possible product and support, please send us your comments and suggestions. I-MED Pharma Inc. 1601 St-Regis Blvd. Dollard-des-Ormeaux, QC Canada H9B 3H7 Authorized Representative in the EU: Medes Ltd. 5 Beaumont Gate, Shenley Hill, Radlett Herts WD7 7AR United Kingdom Tel.: +423 663 169205 Fax: +44 1923 859 810 E-mail: medes@arazygroup.com www.medeseurope.com Marking by the CE symbol indicates compliance of this device as a Class 1 medical device with a measuring function, with the Medical Device Directives 93/42/ EEC as amended by 2007/47/CE. 1. ABOUT THIS MANUAL 4 1.1. Warnings and Precautions 4 2. ESSENTIAL PRESCRIBING INFORMATION 5 2.1. Device Description 5 2.2. Intended Use 5 2.3. Indications 5 2.4. Contraindications 5 2.5. General Safety Instructions 6 3. DESCRIPTION OF COMPONENTS 7 3.1. Identifying System Components 7 3.2. I-PEN Osmolarity System 7 3.3. I-PEN Osmolarity Test Sensor 7 4. PERFORMING AN OSMOLARITY MEASUREMENT 8 4.1. Prepare the I-PEN for Use 8 4.1.1. Insert the Battery 8 4.2. Remove the Single-Use-Sensor from Package 9 4.3. Insert the Single-Use-Sensor 9 4.4. Turn on the Device 10 4.5. Taking a Reading 10 4.5.1. Tips for Use 10 4.6. Eject the Single-Use-Sensor 11 5. EXPECTED RESULTS 11 5.1. Reference Tear Osmolarity Values 11 6. CLEANING AND MAINTENANCE 12 6.1. Cleaning 12 6.1.1. I-PEN Device 12 6.1.2. Single-Use-Sensors 12 6.2. Maintenance 12 6.2.1. Troubleshooting 12 7. OPERATING AND STORAGE CONDITIONS 13 8. TECHNICAL SPECIFICATIONS 13 9. ELECTROMAGNETIC EMISSIONS 14 10. ELECTROMAGNETIC IMMUNITY 15 10.1. Recommended Separation Distances 17 10.1.1. Applicable Standards 17 11. LABELS AND SYMBOLS 18 11.1. Labels 18 11.2. Symbols 18 2 3

I-PEN User Guide ABOUT THIS MANUAL I-PEN User Guide ESSENTIAL PRESCRIBING INFORMATION 1. ABOUT THIS MANUAL This manual provides the information necessary to operate the I-PEN system in a safe and efficient manner. Please read and thoroughly understand this manual before operating the system. If any part of this manual is not clear, contact customer support for clarification. 1.1. WARNINGS AND PRECAUTIONS Three types of special messages appear in this User Manual: A WARNING indicates the possibility of injury, death or other serious adverse reactions associated with the use or misuse of the device. A CAUTION indicates the possibility of a problem with the device associated with its use or misuse. Such problems include device malfunctions, device failure, damage to the device or damage to other property. A NOTE provides other important information. 2. ESSENTIAL PRESCRIBING INFORMATION 2.1. DEVICE DESCRIPTION The I-PEN Osmolarity System is a diagnostic testing device for the quantitative measurement of osmolarity (concentration of dissolved, active particles in solution) of ocular tissues in normal and Dry Eye Disease patients. The I-PEN is for professional in vivo diagnostic use only. When either the quantity or quality of secreted tears is compromised (known as aqueous deficient or evaporative Dry Eye Disease), increased rates of evaporation lead to a concentrated tear film (increased osmolarity) that places stress on the corneal epithelium and conjunctiva. The I-PEN Osmolarity Single-Use-Sensor, in conjunction with the I-PEN Osmolarity System, provides a quick and simple method for determining tear osmolarity using impedance measurements of the saline concentration of the extracellular fluid contained in the eyelid tissue. To perform a test, attach a new Single-Use-Sensor onto the System Reader and touch the tip of the Single-Use-Sensor to the inner tissue of the lower eyelid. After several seconds of contact with the eyelid tissue, the I-PEN will display a quantitative tear osmolarity test result on the liquid crystal display (LCD). The I-PEN Osmolarity System simplifies the osmolarity determination process by eliminating the need to transfer tear fluid samples and reducing the risk of evaporation. The I-PEN Osmolarity Test utilizes an impedance measurement to provide an assessment of osmolarity of the conjunctival tissues surrounding the eye. 2.2. INTENDED USE The I-PEN Osmolarity System is a device for the quantitative measurement of osmolarity (concentration of dissolved, active particles in tissue immersed in solution) of human tears in normal and Dry Eye Disease patients. The I-PEN Osmolarity System should be used only by a trained clinician or under the supervision of a trained clinician. 2.3. INDICATIONS The I-PEN Osmolarity Device is indicated for use in the diagnosis of certain ocular surface disorders which affect the osmolarity of the tear film on the surface of the eye. 2.4. CONTRAINDICATIONS There are no contraindications known at this time. 4 5

I-PEN User Guide GENERAL SAFETY INSTRUCTIONS I-PEN User Guide DESCRIPTION OF COMPONENTS 2.5. GENERAL SAFETY INSTRUCTIONS 3. DESCRIPTION OF COMPONENTS WARNING: Changes or modifications not expressly approved by I-MED Pharma Inc. can affect the safety and effectiveness of the system and will void the system s warranty. WARNING: Use only indoors, in a clean, dry environment. WARNING: Do not use a Single-Use-Sensor that is physically damaged. WARNING: The system contains no user-serviceable components. WARNING: Medical device regulations restrict the operation of the application to trained and qualified personnel. WARNING: Do not test patients who have used eye drops within two hours prior to testing. 3.1. IDENTIFYING SYSTEM COMPONENTS The figures which follow illustrate the components of the I-PEN System. 3.2. I-PEN OSMOLARITY SYSTEM The I-PEN is a portable hand held battery- operated unit that calculates and displays the osmolarity test result. The unit includes a small display screen that shows the osmolarity test result. On/Off switch Battery cover WARNING: Do not test patients wearing makeup on eyelids. WARNING: Do not test patients within 10 minutes after removal of eye makeup. WARNING: Do not test patients after ocular surface staining. WARNING: Do not test patients after invasive ocular diagnostic testing. WARNING: Do not test patients within 10 minutes after a slit lamp examination. WARNING: Do not test a patient who has been crying. Ready button LCD display CAUTION: The information contained in this Manual is intended for the sole and exclusive use of the Company s customers. Any other unauthorized use of this Manual or any of the information it contains is prohibited. CAUTION: Refer all service problems to a qualified I-MED Pharma Inc. representative only. CAUTION: Replace the device if the LCD is cracked, unreadable, has missing pixels, or is otherwise damaged. CAUTION: Replace the device if a beep is not heard after turning it on. CAUTION: Check the operation of the device prior to use. Replace if damaged. CAUTION: Replace the device if the casing or battery cover is lost or damaged. CAUTION: Single-Use-Sensors are for single use only. CAUTION: Do not use the Single-Use-Sensors past the expiration date. Unit cover 3.3. I-PEN OSMOLARITY TEST SENSOR Each Single-Use-Sensor is a single- use, individually packaged unit, designed to work in conjunction with the I-PEN. The Single-Use-Sensor does not contain chemicals or reagents. WARNING: Do not use a Single-Use-Sensor that is physically damaged. CAUTION: Do not use the Single-Use-Sensors past the expiration date. CAUTION: Single-Use-Sensors are for single use only. CAUTION: The device is to be used within a clinical facility environment only. CAUTION: The device is for professional in vivo diagnostic use only. 6 7

I-PEN User Guide PERFORMING AN OSMOLARITY MEASUREMENT I-PEN User Guide PERFORMING AN OSMOLARITY MEASUREMENT 4. PERFORMING AN OSMOLARITY MEASUREMENT WARNING: Do not test patients who have used eye drops within two hours prior to testing. WARNING: Do not test patients wearing makeup on eyelids. WARNING: Do not test patients within 10 minutes after removal of eye makeup. WARNING: Do not test patients after ocular surface staining. WARNING: Do not test patients after invasive ocular diagnostic testing. 4.2. REMOVE THE SINGLE-USE-SENSOR FROM PACKAGE 1. Tear along the dotted line to separate the attached 1, wrapped Single-Use-Sensors. 2. Grasping the bottom firmly with one hand 2, with the other hand tear in the direction of the pre-cut section to expose the end of the Single-Use-Sensor 3 to be inserted into the I-PEN device. 1 2 3 WARNING: Do not test patients within 10 minutes after a slit lamp examination. WARNING: Do not test a patient who has been crying. 4.1. PREPARE THE I-PEN FOR USE WARNING: Use only indoors, in a clean, dry environment. In order to prepare for a test, place the battery in the System Reader, and insert a Single-Use-Sensor. 4.1.1. INSERT THE BATTERY 4.3. INSERT THE SINGLE-USE-SENSOR CAUTION: Replace the device if a beep is not heard after turning it on. CAUTION: It is important to visually inspect the Single-Use-Sensor before use. In the case of suspected contamination, or if the expiration date is expired, replace the Test Sensor. CAUTION: Do not touch the gold nodes while inserting the Single-Use-Sensor. CAUTION: This device uses a battery type CR2032 only. The battery compartment can be accessed by removing the battery cover, as shown below. First 4 remove the unit cover, then 5 insert the disposable Single-Use-Sensor 4 5 CAUTION: Replace the device if the casing or battery cover is lost or damaged. WARNING: Do not use a Single-Use-Sensor that is physically damaged. 8 9

I-PEN User Guide PERFORMING AN OSMOLARITY MEASUREMENT I-PEN User Guide EXPECTED RESULTS 4.4. TURN ON THE DEVICE 4.6. EJECT THE SINGLE-USE-SENSOR 6 7 Push the On/Off switch 6. You should hear a beep and the LCD display 7 should display the I-PEN Ready message. Push the Ejector button and the Single-Use-Sensor will be ejected. You may now discard the Single-Use-Sensor. CAUTION: Replace the device if a beep is not heard after turning it on. NOTE: In order to conserve battery life, the I-PEN is programmed to enter Sleep Mode automatically thirty seconds after it powers up. In doing so, this can invalidate the SUS and a new SUS should be inserted. CAUTION: Do not use the unit if the Reader does not display I-PEN Ready. The LCD will display a test result. See the next Section for a discussion of how to interpret the measurement results. 4.5. TAKING A READING 1. Ask the patient to gently squeeze their eyelids shut for 30-60 seconds prior to taking a reading. 2. Position the tip of the disposable Single-Use-Sensor just above the lower eyelid with the LCD screen facing upwards. 3. Turn on the I-PEN as indicated in section 4.4 only when you are ready to take the reading by pushing the on/off switch to the on position. 5. EXPECTED RESULTS I-PEN test results are displayed on the LCD in units of mosms/l. No calculations are required. The chart below shows some typical test results and their possible interpretation. All such interpretations are subject to the review of the physician or other medical professional. DRY EYE SEVERITY SCALE 275 290 305 320 335 350 365 380 4. Approach at a 30-45 degree angle from horizontal and gently lower the end of the Single-Use- Sensor on to the conjunctiva on the inside of the lower eyelid. Normal < 290 Marginal 290-310 Mild 310-330 Moderate 330-350 Severe > 350 5. When correctly placed, the tip of the Single-Use-Sensor should be depressing the surface slightly so that both gold nodes are in good contact with the conjunctiva. 6. The I-PEN will take make an audible beep after several seconds and display the reading on the LCD screen. 4.5.1. TIPS FOR USE 1. Do not immerse the tip of the Single-Use-Sensor in the lower tear meniscus. 2. If the reading on the LCD screen shows an Error, you may attempt another reading in the same eye by pressing the Ready button. 5.1. REFERENCE TEAR OSMOLARITY VALUES Reading in mosms/l (Use result from eye with highest reading) Variance Between Right & Left Eye Interpretation <290 Normal Patient 290-310 7 Normal Patient 290-310 8 Dry Eye Disease Patient >310 Dry Eye Disease Patient 10 11

I-PEN User Guide CLEANING AND MAINTENANCE I-PEN User Guide OPERATING AND STORAGE CONDITIONS TECHNICAL SPECIFICATIONS 6. CLEANING AND MAINTENANCE 7. OPERATING AND STORAGE CONDITIONS 6.1. CLEANING WARNING: Cleaning fluids should never be used on the Single-Use-Sensor. 6.1.1. I-PEN DEVICE The I-PEN can be cleaned with a damp cloth or alcohol wipe as required. When cleaning, it is important to keep the electronic contacts of the control unit and Reader dry. The electronic contacts and docking port should also be kept free of dust and dirt. To ensure warranty coverage and reliable system operation, defective system components should be serviced and/or replaced exclusively by I- MED Pharma Inc. authorized personnel, and replacement parts should be those specified by the manufacturer. It is important to use and store the device within the environmental conditions shown in the table below. Transport and Storage Temperature Transport and Storage Relative Humidity 2 35 C/36 95 F 10 85% non- condensing 6.1.2. SINGLE-USE-SENSORS Single-Use-Sensors are for use on a single eye. Never reuse or try to clean a Single-Use-Sensor. Single-Use-Sensors may be ordered on line at www.imedpharma.com or by calling your representative at I- MED Pharma Inc. Tel. Number: (800) 463-1008 or (514) 685-8118. Transport and Storage Altitude Operating Temperature Operating Altitude 0 2,000 meters 15 30 C/59 86 F 0 2,000 meters 6.2. MAINTENANCE The I-PEN Osmolarity System is designed to work without direct service or preventive maintenance. If quality checks fail, contact I-PEN Customer Support. Battery should be replaced when Low Bat indication appears on the screen. 6.2.1. TROUBLESHOOTING Single-Use-Sensors are for single use only. Never reuse or try to clean a Single-Use-Sensor. Operating Relative Humidity 8. TECHNICAL SPECIFICATIONS Calibration Degree of Protection Against Electric Shock 10 85% non- condensing No calibration required BF Type applied part NOTE: If the Recommended Action does not solve the problem, contact I- MED Pharma Inc. Customer Support. Size (not including probe holder) W 140mm L 223mm H 140mm Condition Possible Cause Recommended Action The I-PEN Ready message does not display A beep is not heard when the device is turned on Low Bat indication appears on screen Screen goes dim Battery not installed. Device malfunction. Device malfunction. Battery close to end-of-life. Battery close to end-of-life. Verify that the correct type of battery is installed, and that the battery is fresh. Contact I-PEN customer support. Contact I-PEN customer support. Replace battery. Replace battery. Weight 50 gm Battery CR2032 Frequency 80 Hz Peak Voltage ± 1.5V Current Source Max100 μa AC Sinus Distortions 5% 12 13

I-PEN User Guide ELECTROMAGNETIC EMISSIONS I-PEN User Guide ELECTROMAGNETIC IMMUNITY 9. ELECTROMAGNETIC EMISSIONS 10. ELECTROMAGNETIC IMMUNITY NOTES The I-PEN requires special precautions with regard to electromagnetic compatibility. It must be installed and prepared for use as described in Section 4. Performing an Osmolarity Measurement. Certain types of mobile telecommunication devices such as mobile telephones are likely to interfere with the I-PEN. The recommended separation distances in this paragraph must therefore be complied with. The I-PEN must not be used near or on top of another device. If this cannot be avoided, it is necessary before clinical use to check the equipment for correct operation under the conditions of use. The use of accessories other than those specified or sold by I- MED Pharma Inc. as replacement parts may have the consequence of increasing the emissions or decreasing the immunity of the unit. I-PEN is intended for use in the electromagnetic environment specified in the following tables. This is not a life- sustaining device. The user and/or installer of the unit must ensure that it is used in such an environment. Guidance and Manufacturer s Declaration - Electromagnetic Emissions The I-PEN is intended for use in the electromagnetic environment specified below. The customer or the user of the I-PEN device should assure that it is used in such an environment. Emissions Test RF emissions Test: CISPR 11 RF emissions CISPR 11 Harmonic emissions IEC 61000-3- 2 Voltage fluctuations/flicker emissions IEC 61000-3-3 Compliance Group 1 Class B Electromagnetic Environment - Guidance The I-PEN uses RF energy only for its internal function. Therefore, its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment. Guidance and Manufacturer s Declaration - Electromagnetic Immunity The I-PEN is intended for use in the electromagnetic environment specified below. The customer or the user of the I-PEN device should assure that it is used in such an environment. Immunity Test Electrostatic discharge (ESD) IEC 61000-4-2 Electrical fast transient/burst IEC 61000-4-4 Surge IEC 61000-4-5 Voltage fluctuations/ flicker emissions IEC 61000-3-3 Power frequency (50/60 Hz) magnetic field IEC 61000-4-8 IEC 60601-1-2 Test Level ±6 kv contact ±8 kv air ±2 kv for power supply lines ±1 kv for input/ Output lines ±1 kv differential mode ±2 kv common mode <5 %UT (>95 %dip in UT) for 0.5 cycle 40 %UT (60 %dip in UT) for 5 cycles <5 %UT 70 %UT (30 %dip in UT) for 25 cycles <5 %UT <5 %UT (>95 %dip in UT) for 5 s 3 A/m 3 A/m Compliance Level ±8 kv contact ±8 kv air Electromagnetic Environment- Guidance Floors should be wood, concrete or ceramic tile. If floors are covered with synthetic material, the relative humidity should be at least 30%. Power frequency magnetic fields should be at levels characteristic of a typical public low voltage power supply network that supplies buildings used for domestic purposes, commercial or hospital, clinic environment. 14 15

I-PEN User Guide ELECTROMAGNETIC IMMUNITY I-PEN User Guide ELECTROMAGNETIC IMMUNITY Guidance and Manufacturer s Declaration - Electromagnetic Immunity The I-PEN is intended for use in the electromagnetic environment specified below. The customer or the user of the I-PEN device should assure that it is used in such an environment. 10.1. RECOMMENDED SEPARATION DISTANCES Recommended separation distances between portable and mobile RF communications equipment and the I-PEN Immunity Test IEC 60601-1-2 Test Level Conducted RF IEC 61000-4-6 Radiated RF IEC 61000-4-3 3 Vrms 150kHz to 80MHz 3 V/m 80MHz to 2.5GHz Compliance Level 3 V/m Electromagnetic Environment- Guidance Portable and mobile RF communications equipment should be used no closer to any part of the I-PEN, including cables, than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter. Recommended separation distance d = 1.17 P The I-PEN is intended for use in an electromagnetic environment in which radiated radio frequency disturbances are controlled. The user and/or installer of the unit can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile radio frequency communications equipment (emitters) and the I-PEN, according to the maximum output power of the equipment, as recommended in the table below. Rated maximum output power of transmitter (W) Separation distance according to the frequency of transmitter (m) 80MHz to 800MHz d = 1.17 P 0.01 0.12 0.23 800MHz to 2.5GHz d = 2.3 P d = 1.17 P 80 M Hz t o 800 MHz 0.1 0.37 0.73 d = 2.3 P 800 MHz t o 2.5 GHz 1 1.17 2.3 Where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer and d is the recommended separation Distance in meters (m). Field strengths from fixed R F transmitters, as determined by an electromagnetic site survey, a should be less than the compliance level in each frequency range Interference may occur in the vicinity of equipment marked with the following symbol: 10 3.7 7.3 100 11.7 23 For transmitters rated at a maximum output power not listed above, the recommended separation distance d in meters (m) can be estimated using the equation applicable to the frequency of the transmitter, where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer. NOTE 1 At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies. NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects, and people. 10.1.1. APPLICABLE STANDARDS The following list of standards applies to the I-PEN Osmolarity Device: IEC/EN/UL 60601-1: 2005 (3rd Ed.), Medical electrical equipment, part 1: General requirements for basic safety and essential performance. NOTE 1 At 80 MHz and 800 MHz, the higher frequency range applies. NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures objects and people. a Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the I-PEN is used exceeds the applicable RF compliance level above, the I-PEN should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as re-orienting or relocating the I-PEN. IEC/EN 60601-1-2: 2007, Medical Electrical Equipment- Part 1-2: General requirements for safety Collateral standard: Electromagnetic compatibility Requirements and tests. IEC 62304: 2006, Medical Device Software Software Lifecycle Processes. ISO 15223: 2012, Medical devices Symbols to be used with medical device labels, labeling and information to be supplied Part 1: General requirements. ISO 10993-1: 2009, Biological Evaluation for Medical Devices, part 1 Evaluation and testing within a risk management process. 16 17

I-PEN User Guide LABELS AND SYMBOLS I-PEN User Guide 11. LABELS AND SYMBOLS 11.1. LABELS REF: 600 SN: nn-xxxx mm-yyyy OSMOLARITY SYSTEM LifeCare Ltd. 2 Zipori Street Tiberias 1424602 Israel PRT-14-200 Rev. 01 11.2. SYMBOLS A number of internationally recognized symbols are found on the I-PEN unit. These relate to safety requirements and standards and are briefly reviewed below. Symbol Symbol meaning Attention: Consult Accompanying Document BF type applied part Month/Year of Manufacture Manufactured by Manufactured by: Life Care Ltd 2 Zipori Street Tiberias 1424602 Israel Distributed by: Special Requirements for Waste of Electrical and Electronic Equipment (WEEE Directive) CE Compliance (Medical Device Directive) CAUTION: At the end of its useful life, the system must be disposed of in accordance with local law and/or code concerning electrical and electronic equipment. 1601 St-Regis Blvd. Dollard-des-Ormeaux, QC Canada H9B 3H7 Tel: (514) 685-8118 Toll free: (800) 463-1008 Fax: (514) 685-8998 Email: info@imedpharma.com Website: www.imedpharma.com 18 19

I-MED Pharma Inc. 1601 St-Regis Blvd. Dollard-des-Ormeaux, QC Canada H9B 3H7 Tel: (514) 685-8118 Toll free: (800) 463-1008 Fax: (514) 685-8998 info@imedpharma.com SEE THE DIFFERENCE Product #IPUMEN 0718