G3 G3 Key features: 4 selectable operation modes on each model External start, reset, and gate inputs Panel mount or socket mount Large variety of timing functions and output status indicating LEs Specifications UL, c-ul Listed File No. E55996 G3 Series nalog G3-1 G3-2 G3-3 G3-4,-5,-6 Multi-mode Multi-mode with inputs (11 pins) ime Range Rated Voltage ontact Ratings Minimum pplicable Load Voltage olerance Error Setting Error ime Insulation Resistance ielectric Strength onsumption (approximate) elayed SP 10.8V (200V, 60Hz) 125V /250V, 3; 30V, 1 (resistive load) 0.1s to 180 hours 100 to 240V, 50/60Hz 12V 24V, 50/60Hz / 24V 5V, 10m (reference value) F20 (100V ): 85 to 264V 24: 20.4 to 26.4V /21.6 to 26.4V 12: 10.8 to 13.2V ±0.2%, ±10 msec (repeat, voltage, temperature) ±10% maximum 60msec maximum 100MW minimum etween power and output terminals: 2,000V, 1 minute etween contacts of different poles: 2,000V, 1 minute etween contacts of the same pole: 750V, 1 minute elayed SP + elayed P instantaneous SP 13.5V (200V, 60Hz) 12V/1W 24V/0.7W 24V/1.2V 14.4V (200V, 60Hz) 12V/1.1W 24V/0.6W 24V/1.3V 125V /250V, 5; 30V, 5 (resistive load) elayed P 4.7V (100V, 60Hz), 14.4V (200V, 60Hz) 12V/0.8W 24V/0.6W 24V/1.3V Mechanical Life 10,000,000 operations minimum 5,000,000 operations minimum Electrical LIfe 50,000 operations minimum (rated load) 100,000 operations minimum (rated load) Weight (approximate) 63g 73g 79g 80g Vibration Resistance 100m/sec 2 (approximate 10G) Shock Resistance Operating extremes: 100m/sec 2 (approximate 10G) amage limits: 500m/sec 2 (approximate 50G) Operating emperature 10 to +50 Operating Humidity 45 to 85% RH Storage emperature 30 to +80 Housing olor Gray Switches & Pilot Lights Signaling Lights Relays & Sockets ontactors erminal locks ircuit reakers 800-262-IE (4332) US & anada 843
G3 Switches & Pilot Lights Signaling Lights G3-1, -2, -3 : ON-delay 1 : Interval 1 : ycle 1 : ycle 3 Mode Of Part Numbers Rated Voltage ode ime Range Output ontact F20: 100 to 240V (50/60Hz) F20: 100 to 240V (50/60Hz) 12: 12V 24: 24V (50/60Hz)/24V 0.1 seconds to 180 hours 250V, 3, 30V, 1 (resistive load) 240V, 5, 24V, 5 (resistive load) 1. For wiring schematics and timing diagrams for G3-1, -2, -3, see pages page 845 and page 846 respectively. 2. For more details about time ranges, see instructions on page page 850. 3. For socket and accessory part numbers, see page 860. 8-Pin omplete Part No. 11-Pin elayed SP G3-1F20 G3-1EF20 elayed SP + Instantaneous SP elayed P G3-2F20 G3-212 G3-224 G3-3F20 G3-312 G3-324 G3-2EF20 G3-2E12 G3-2E24 G3-3EF20 G3-3E12 G3-3E24 G3-4, -5, -6 Relays & Sockets Mode of : ON-elay 2 : ycle 2 : Signal ON/OFF-elay 1 : Signal OFF-elay 1 Rated Voltage ode ime Range Output ontact Input F20: 100 to 240V (50/60Hz) 12: 12V 24: 24V (50/60Hz)/24V omplete Part No. (11-pin) (11-pin) G3-4F20 G3-4EF20 G3-412 G3-4E12 G3-424 G3-4E24 : Interval 2 : One-Shot ycle : Signal ON/OFF-elay 2 : Signal OFF-elay 2 : One-Shot : One-Shot ON-elay : One-Shot 2 : Signal ON/OFF-elay 3 F20: 100 to 240V (50/60Hz) 24: 24V (50/60Hz)/24V 0.1 seconds to 180 hours 250V, 5, 24V, 5 (resistive load) elayed P Gate G3-5F20 G3-524 G3-6F20 G3-624 G3-5EF20 G3-5E24 G3-6EF20 G3-6E24 ontactors 4. For wiring schematics and timing diagrams G3-4,-5,-6, see pages 832, 833, and 833 respectively. 5. For more details about time ranges, see instructions on page 850. 6. (11-pin) and (11-pin) differ in the way inputs are wired. 7. For socket and accessory part numbers, see page 860. 8. For the timing diagrams overview, see page 832. ircuit reakers erminal locks 844 www.ie.com
G3 G3-1 iming iagrams elayed SP Mode Selection ON-elay 1 Interval 1 ycle 1 (OFF first) ycle 3 (ON first) elayed 8-11 (11p) ontact 6-8 (8p) (11p) elayed 8-11 (11p) ontact 6-8 (8p) (11p) elayed 8-11 (11p) ontact 6-8 (8p) (11p) elayed 8-11 (11p) ontact 6-8 (8p) (11p) iming iagrams/schematics Switches & Pilot Lights Signaling Lights Relays & Sockets ontactors erminal locks ircuit reakers 800-262-IE (4332) US & anada 845
G3 Switches & Pilot Lights G3-2 iming iagrams elayed SP + Instantaneous SP Mode Selection G3-3 iming iagrams elayed P Mode Selection Signaling Lights ON-elay 1 elayed 8-11 (11p) ontact 6-8 (8p) (11p) Instantaneous ontact 1-3 ON-elay 1 1-4, elayed 1-4, 8-11 (11p) ontact 1-3, 6-8 (8p) 1-3, (11p) ontactors Relays & Sockets Interval 1 ycle 1 (OFF first) elayed 8-11 (11p) ontact 6-8 (8p) (11p) Instantaneous ontact 1-3 elayed 8-11 (11p) ontact 6-8 (8p) (11p) Instantaneous ontact 1-3 Interval 1 ycle 1 (OFF first) ycle 3 (ON first) 1-4, elayed 1-4, 8-11 (11p) ontact 1-3, 6-8 (8p) 1-3, (11p) 1-4, elayed 1-4, 8-11 (11p) ontact 1-3, 6-8 (8p) 1-3, (11p) 1-4, elayed 1-4, 8-11 (11p) ontact 1-3, 6-8 (8p) 1-3, (11p) erminal locks ycle 3 (ON first) elayed 8-11 (11p) ontact 6-8 (8p) (11p) Instantaneous ontact 1-3 ircuit reakers Note: Pins 1, 3, and 4 are the instantaneous contacts. 846 www.ie.com
G3 G3-4 iming iagrams elayed P Mode Selection ON-elay 2 ycle 2 Signal ON/OFF-elay 1 Signal OFF-elay 1 2-10 Input elayed ontact Gate 2-5 () 8-11 1-3 a ' " 2-10 Gate 2-5 () elayed 8-11 ontact 1-3 a " " 2-10 Gate 2-5 () elayed 8-11 ontact 1-3 a a " a 2-10 Gate 2-5 () elayed 8-11 ontact 1-3 = Set time a = Shorter than set time = ' + " a a Switches & Pilot Lights Signaling Lights Relays & Sockets ontactors erminal locks ircuit reakers 800-262-IE (4332) US & anada 847
G3 Switches & Pilot Lights G3-5 iming iagrams elayed P Mode Selection Signaling Lights Relays & Sockets Interval 2 2-10 Input elayed ontact Gate 2-5 () 8-11 1-3 a ' " 2-10 One-Shot ycle Input elayed ontact Gate 2-5 () 8-11 1-3 a ' " ontactors erminal locks ircuit reakers Signal ON/OFF-elay 2 Signal OFF-elay 2 2-10 Gate 2-5 () elayed 8-11 ontact 1-3 a a a ' " a 2-10 Gate 2-5 () elayed 8-11 ontact 1-3 = Set time a = Shorter than set time = ' + " a a ' " 848 www.ie.com
G3 G3-6 iming iagrams elayed P Mode Selection One-Shot 1 One-Shot ON-elay One-Shot 2 Signal ON/OFF-elay 3 2-10 Input elayed ontact Gate 2-5 () 8-11 1-3 a a a ' " 2-10 Gate 2-5 () elayed 8-11 ontact 1-3 a ' " 2-10 Gate 2-5 () elayed 8-11 ontact 1-3 a ' " 2-10 Gate 2-5 () elayed 8-11 ontact 1-3 = Set time a = Shorter than set time = ' + " a ' " a a Switches & Pilot Lights Signaling Lights Relays & Sockets ontactors erminal locks ircuit reakers 800-262-IE (4332) US & anada 849
G3 Switches & Pilot Lights imed Instructions: Setting G3 Series (flashes during time-delay period) m Setting Knob Signaling Lights j Operator Mode Selector,,, l ime Range Selector 1S, 10S, 10M, 10H k ial Selector 0-1, 0-3, 0-6, 0-18 ircuit reakers erminal locks ontactors Relays & Sockets Step 1. esired Mode of Selection Remarks For Mode of j Mode Selector ON-delay 1 G3-1 Interval 1 G3-2 G3-3 ycle 1 ycle 3 ON-delay 2 G3-4 ycle 2 Signal ON/OFF-delay 1 Signal OFF-delay 1 Interval 2 G3-5 One-shot cycle Signal ON/OFF-delay 2 Signal OFF-delay 2 One-shot 1 G3-6 One-shot ON-delay One-shot 2 Signal ON/OFF-delay 3 Step 2. esired ime Range Selection Remarks ime Ranges k ial Selector l ime Range Selector 0.1 seconds to 1 second 0-1 Select the desired mode of operation. Select the time range that contains the desired time period. 0.1 seconds to 3 seconds 0-3 0.1 seconds to 6 seconds 0-6 0.15 seconds to 18 seconds 0-18 0.1 seconds to 10 seconds 0-1 0.3 seconds to 30 seconds 0-3 0.6 seconds to 60 seconds 0-6 1.8 seconds to 180 seconds 0-18 6 seconds to 10 minutes 0-1 18 seconds to 30 minutes 0-3 36 seconds to 60 minutes 0-6 108 seconds to 180 minutes 0-18 6 minutes to 10 hours 0-1 18 minutes to 30 hours 0-3 36 minutes to 60 hours 0-6 108 minutes to 180 hours 0-18 Step 3. Set the precise period of time desired by using the m Setting Knob. 1S 10S 10M 10H Selection he desired operation mode can be selected from the,,, and modes using the Mode Selector. hange the operation mode from to,, and in turn by turning the operation mode selector clockwise using a flat screwdriver which is a maximum of 0.156 (4mm) wide. he selected mode is displayed in the window. he desired time range is selected by setting both k ial Selector and l ime Range Selector. 850 www.ie.com