The Simbol-X focal plane

Similar documents
SIMBOL-X. Peter Lechner MPI-HLL Project Review Schloss Ringberg, science background. mission. telescope.

The focal plane of the Simbol X space mission

The Simbol-X. Low Energy Detector. Peter Lechner PNSensor & MPI-HLL. on behalf of the LED consortium. Paris, Simbol-X Symposium. P.

Caliste 64, an innovative CdTe hard X-ray micro-camera

The Digital Data Processing Unit for the HTRS on board IXO

The Wide Field Imager

STATE-OF-THE-ART SILICON DETECTORS FOR X-RAY SPECTROSCOPY

Single Photon Counting in the Visible

Light gathering Power: Magnification with eyepiece:

Active Pixel Matrix for X-ray Satellite Missions

Chromatic X-Ray imaging with a fine pitch CdTe sensor coupled to a large area photon counting pixel ASIC

Strip Detectors. Principal: Silicon strip detector. Ingrid--MariaGregor,SemiconductorsasParticleDetectors. metallization (Al) p +--strips

ITk silicon strips detector test beam at DESY

Pixel hybrid photon detectors

Highly Miniaturised Radiation Monitor (HMRM) Status Report. Yulia Bogdanova, Nicola Guerrini, Ben Marsh, Simon Woodward, Rain Irshad

Wide field imager instrument for the Advanced Telescope for High Energy Astrophysics

Spectroscopic Performance of DEPFET active Pixel Sensor Prototypes suitable for the high count rate Athena WFI Detector

A Prototype Amplifier-Discriminator Chip for the GLAST Silicon-Strip Tracker

Marten Bosma 1, Alex Fauler 2, Michael Fiederle 2 en Jan Visser Nikhef, Amsterdam, The Netherlands 2. FMF, Freiburg, Germany

erosita mirror calibration:

A Novel Design of a High-Resolution Hodoscope for the Hall D Tagger Based on Scintillating Fibers

Semiconductor Detector Systems

The superconducting microcalorimeters array for the X IFU instrument on board of Athena Luciano Gottardi

The Wide Field Imager Instrument for Athena

Wide Field Imager for Athena

THE CCD RIDDLE REVISTED: SIGNAL VERSUS TIME LINEAR SIGNAL VERSUS VARIANCE NON-LINEAR

MPE's views on SDDs as focal plane detectors for SFA

PROJECT IGOSAT June 10th 2016

How Does One Obtain Spectral/Imaging Information! "

PNCCD for photon detection from near infrared to X-rays

Development of a Highly Selective First-Level Muon Trigger for ATLAS at HL-LHC Exploiting Precision Muon Drift-Tube Data

The Wide Field Imager for the Athena X-ray Observatory

Lecture 2. Part 2 (Semiconductor detectors =sensors + electronics) Segmented detectors with pn-junction. Strip/pixel detectors

Development of Pixel Detectors for the Inner Tracker Upgrade of the ATLAS Experiment

DELIVERABLE!D60.4! 1k!x!1k!pnCCD!Conceptual!Design! WP60!Advanced!Instrumentation!Development! 1 ST Reporting Period.

Detectors that cover a dynamic range of more than 1 million in several dimensions

Detectors for AXIS. Eric D. Miller Catherine Grant (MIT)

Ground-based optical auroral measurements

Silicon Drift Detector. with On- Chip Ele ctronics for X-Ray Spectroscopy. KETEK GmbH Am Isarbach 30 D O berschleißheim GERMANY

OPAL Optical Profiling of the Atmospheric Limb

Page 1. Ground-based optical auroral measurements. Background. CCD All-sky Camera with filterwheel. Image intensifier

Preparing for the Future: Upgrades of the CMS Pixel Detector

Low Cost Earth Sensor based on Oxygen Airglow

Initial Results from a Cryogenic Proton Irradiation of a p-channel CCD

EVALUATION OF RADIATION HARDNESS DESIGN TECHNIQUES TO IMPROVE RADIATION TOLERANCE FOR CMOS IMAGE SENSORS DEDICATED TO SPACE APPLICATIONS

A LATERAL SENSOR FOR THE ALIGNMENT OF TWO FORMATION-FLYING SATELLITES

NEAT breadboard system analysis and performance models

THE CALIBRATION OF THE OPTICAL IMAGER FOR THE HOKU KEA TELESCOPE. Jamie L. H. Scharf Physics & Astronomy, University of Hawai i at Hilo Hilo, HI 96720

Studies on MCM D interconnections

Gas scintillation Glass GEM detector for high-resolution X-ray imaging and CT

Development and Test of a Demonstrator for a First-Level Muon Trigger based on the Precision Drift Tube Chambers for ATLAS at HL-LHC

A high energy gamma camera using a multiple hole collimator

Mission requirements and satellite overview

High granularity scintillating fiber trackers based on Silicon Photomultiplier

1.1 The Muon Veto Detector (MUV)

AN INTRODUCTION TO MICROCARB, FIRST EUROPEAN PROGRAM FOR CO2 MONITORING.

Observational Astronomy

Fast Solar Polarimeter

On the initiation of lightning in thunderclouds (Instrumentation, Supplementary information)

Multi-Lateral Shearing Interferometry: Principle and Application on X-ray Laboratory Sources

236 IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 59, NO. 1, FEBRUARY 2012

Simulation of High Resistivity (CMOS) Pixels

Scintillation Counters

arxiv: v1 [physics.ins-det] 25 Oct 2012

Detailed Characterisation of a New Large Area CCD Manufactured on High Resistivity Silicon

PET Detectors. William W. Moses Lawrence Berkeley National Laboratory March 26, 2002

Backgrounds in DMTPC. Thomas Caldwell. Massachusetts Institute of Technology DMTPC Collaboration

AIAA/USU Small Satellite Conference 2007 Paper No. SSC07-VIII-2

Attenuation length in strip scintillators. Jonathan Button, William McGrew, Y.-W. Lui, D. H. Youngblood

Dynamic Range. Can I look at bright and faint things at the same time?

The Light Amplifier Concept

Production of HPDs for the LHCb RICH Detectors

arxiv: v2 [physics.ins-det] 15 Nov 2017

Diamond sensors as beam conditions monitors in CMS and LHC

Development of New Large-Area Photosensors in the USA

GPI INSTRUMENT PAGES

Performance of 8-stage Multianode Photomultipliers

Properties of Irradiated CdTe Detectors O. Korchak M. Carna M. Havranek M. Marcisovsky L. Tomasek V. Vrba

Radiometric Solar Telescope (RaST) The case for a Radiometric Solar Imager,

Selecting an image sensor for the EJSM VIS/NIR camera systems

The HPD DETECTOR. Michele Giunta. VLVnT Workshop "Technical Aspects of a Very Large Volume Neutrino Telescope in the Mediterranean Sea"

The Asteroid Finder Focal Plane

Upgrade of the ultra-small-angle scattering (USAXS) beamline BW4

The Influence of Edge Effects on the Detection Properties of Detector Grade Cadmium Telluride

The CMS Outer HCAL SiPM Upgrade.

Phase 1 upgrade of the CMS pixel detector

Designing an MR compatible Time of Flight PET Detector Floris Jansen, PhD, Chief Engineer GE Healthcare

Test Beam Measurements for the Upgrade of the CMS Phase I Pixel Detector

Status of the Continuous Ion Back Flow Module for TPC Detector

The Compact Muon Solenoid Experiment. Conference Report. Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

XRF Instrumentation. Introduction to spectrometer

A Large Low-mass GEM Detector with Zigzag Readout for Forward Tracking at EIC

DOCUMENT CHANGE NOTICE (DCN) SHEET 1 OF 1

Thin Silicon R&D for LC applications

A fast Event Preprocessor for the Simbol-X Low-Energy Detector

The Hot and Energetic Universe

Charge Loss Between Contacts Of CdZnTe Pixel Detectors

THE SPACE TECHNOLOGY RESEARCH VEHICLE 2 MEDIUM WAVE INFRA RED IMAGER

R&D ASTROPHYSICS LABORATOIRE SPECTRO-IMAGEURS SPATIAUX SPACE IMAGING-SPECTROMETER LAB MAY 12, 2016 CEA MAY 12, 2016 PAGE 1

Infrared Detectors an overview

Transcription:

Mem. S.A.It. Vol. 79, 32 c SAIt 2008 Memorie della The Simbol-X focal plane P. Laurent 1,4, P. Lechner 2, M. Authier 1, U. Briel 3, C. Cara 1, S. Colonges 4, P. Ferrando 1,4, J. Fontignie 1, E. Kendziorra 5, O. Limousin 1, J. Martignac 1, A. Meuris 1, L. Ravera 6 and Y. Rio 1. 1 CEA/DSM/Dapnia, CEA-Saclay, 91191 Gif sur Yvette Cedex, France 2 Max-Planck-Institut Halbleiterlabor, Munich, Germany 3 Max-Planck-Institut für extraterrestrische Physik, Giessenbachstr., 85748 Garching, Germany 4 AstroParticules et Cosmologie, batiment Condorcet, 10 avenue Alice Domont et Leonie Duquet, 75205 Paris Cedex 13, France 5 Institut fur Astronomy und Astrophysik, Sand 1, 72076 Tubingen, Germany 6 Centre d Etude Spatiale des Rayonnements, 9 avenue du colonel Roche, 31028 Toulouse Cedex 4, France Abstract. The Simbol-X focal plane is designed to detect photons focused by the mirror in the 0.5 to 100 kev energy band. Composed of two detectors, it will measure the position, energy, and arrival time of each incoming X-ray. On top of it will be a collimator to shield all photons not coming from the mirror field of view. The whole system is surrounded by an active and passive shielding in order to ensure the required very low background. Key words. Simbol-X 1. Introduction The Simbol-X detector payload is composed of two separate systems: the X-ray photon camera, called the Focal Plane Assembly or FPA, which is described in part 2, and the collimator, which shields the light not coming from the field of view. The geometry and composition of this collimator is given in part 3. In part 4, we detail the on-board data storage and telemetry rates. Send offprint requests to: P. Laurent, e-mail: plaurent@cea.fr 2. The focal plane assembly The focal plane is composed of two imaging detectors on top of each other, the Low Energy Detector (LED) and the High Energy Detector (HED), described below, and shown in Figure 1. The LED and the HED measure the position in focal plane coordinates, the energy, and the onboard arrival time of each incoming X-ray. Each imaging plane is made of 128 128 pixels, with a pixel size of 625 625 µm 2. This, in conjonction with a mirror with a 15 arcsec Half Energy Width angular resolution (Pareschi et al. 2007) at 20 meters away, provides an oversampling of the Point Spread Function by a factor 2.3.

Laurent et al.: The Simbol-X focal plane 33 Fig. 1. cut view of the focal plane assembly. The active shielding, in orange, is in two parts to surround the imaging detectors. On top is the calibration wheel. The two imaging detectors are placed as close as possible, to be well within the focal depth range (a few cm), taking also into account the relative motion of the two satellites. In addition, in order to avoid any electrical interferences, a aluminum conducting foil is placed between the two detectors. This foil is the only matter between the X-ray detecting materials of the two planes. In order to reduce the background to the required level (Ferrando et al. 2007), the two imaging planes are surrounded by an active and passive shielding (anticoincidence) which encloses them completely, except for the telescope field of view. Lastly, on top of the focal plane assembly, is located a calibration wheel which hold the calibration sources ( 60 Fe and 241 Am). This wheel has also an open position, for observations, and a close position for protection of the detectors during times of high radiation and study of the internal background. 2.1. The low energy detector The heart of the low energy detector is a monolithic macro pixel detector array. The readout scheme of the pixel detector is that of an active pixel sensor, that is a Silicon drift detector with an integrated DEPFET. The Silicon thickness is 450 µm. An aluminum optical blocking filter, 100 nm thick, is deposited directly onto the surface of the LED. The LED mechanical design is shown on Figure 2. The LED quantum efficiency is given in Figure 3, taking into account the 450 µm depletion depth for the bare LED chip (without optical window), and the 100 nm Al filter deposited on the LED.

34 Laurent et al.: The Simbol-X focal plane Fig. 2. LED mechanical design Fig. 4. Example of spectrum measured on a 64 64 pixels device, with a pixel size of 64 µm. The energy resolution is around 130 ev at 6 kev. The operating temperature is 40 C. Fig. 3. Quantum efficiency of the bare LED chip (blue curve) and with the nominal optical filter (red). the LED design allows an excellent energy resolution for relatively high temperatures. An example of what has been achieved on a 64 64 pixels device, with a pixel size of 64 µm is shown on Figure 4. The energy resolution is around 130 ev at 6 kev, for an operating temperature of 40 C. The energy resolution of the LED is dominated by leakage current. The leakage current strongly depends on temperature, on the detector material, the pixel volume and on the integration time. This resolution will degrade with irradiation of the detector. On figure 5 is shown the expected energy resolution for an irradiation by 10 8 protons/cm 2 (10 MeV Fig. 5. expected energy resolution of the LED, as a function of detector temperature. The best to worst leakage current cases are indicated. The green area is before any radiation damage. The orange area is for an irradiation of 10 8 protons/cm 2 (10 MeV equivalent) considered at this stage as an upper limit for 2 years of solar maximum for the orbit of Simbol-X. The red line is the requirement. equivalent), expected after five years of operation in space. The required 150 ev resolution (Ferrando et al. 2007), obtained at the beginning of the mission with an operating temperature of 30 C, can be also achieved at the end of the mission cooling the LED down to 45 C. The LED detector is logically and functionally divided into four quadrants of 64 64

Laurent et al.: The Simbol-X focal plane 35 pixels each, which can be read in parallel. The read out scheme proceeds row by row, and can be flexible. The read-out time of one row is 4 µs in the baseline design, with a CAMEX (Charge Amplifier MutliplEXer) chip. With an upgrade of the read-out electronics, which is under study, the read-out time can be diminished to 2 µs per row. Two main imaging modes are presently considered : i) the full frame mode, in which all the 64 rows of the quadrants are read, giving a 128 128 pixels frame. The baseline readout time is 256 µs. The upgraded readout time is 128 µs. ii) a window mode, in which only a predefined numbers of rows are read for each quadrant. Fig. 6. assembly of the 64 Caliste modules, into 8 sectors of 8 modules each 2.2. The high energy detector The High Energy Detector is a hard X-ray camera made of arrays of Caliste modules of 1 cm 2 arranged in a 8 8 square in order to cover the mirror field of view. The reference configuration is to have 8 sectors of 2 4 modules each, as illustrated in Figure 6. The detector material is a 2 mm thick CdTe (or CdZnTe) crystal which provide the stopping power necessary to detect the focussed photons. A Caliste module is made of a pixellated CdTe crystal mounted on its associated front end electronics. All electrical contacts are routed below, so that the module is four-side buttable; a demonstrator module is shown in Figure 7. Segmented electrodes are defined on each monolithic crystal, by a photolithography process, to define an array in 16 16 pixels. A guard ring, of 50 µm width, is also implemented on the edge of the crystal for spectral resolution and stability reasons. Due to the dead area on the edge, the Caliste filling factor is 96%. During phase A, a number of CdTe and Cd(Zn)Te crystals, of different thickness and contact types, have been systematically characterized in a dedicated test chamber. Spectroscopic measurements have been performed on 64 pixels crystals read-out by the Fig. 7. demonstrator of the Caliste module (CEA - 3Dplus - CNES). IDeF-X V1.0 chip, which is an intermediate development version of the specific Simbol-X chip. The Figure 8 shows the sum spectrum over 64 pixels of a 2 mm thick CdTe Schottky detector operated at - 37C. An excellent spectral response is obtained, with a 0.78 kev resolution at 60 kev, fulfilling the Simbol-X mission requirements. A similar result is obtained for CdZnTe crystals (0.93 kev). The HED is a self-triggered detector, so there is no concept of frame time as for the LED. The read-out of each Caliste module is also independent of the read-out of the other modules. The module read-out time is less than 50 µs, the accuracy of the time tag is better than 300 ns.

36 Laurent et al.: The Simbol-X focal plane by Monte-Carlo simulations (Chipaux et al. 2007), to increase its thickness to 3 mm in order to efficiently reduce the background due to hard X-ray photons. Fig. 8. measured spectrum of a 241 Am source with a CdTe Schottky, 2 mm thick, 64 pixels detector. The operating temperature is 37 C, with an applied bias of 600 V. 2.3. The background reduction system The background reduction system is made of two principal parts. The first part is an active shielding, which gives a fast signal when it is traversed by a charged particle. As this charged particle could generate background signals in the HED or LED (directly, by going also through the imaging detector, or indirectly by generating photons through interactions with the surrounding matter), this fast signal is used as a veto signal for the acquisition of imaging detectors data. The second part is the a passive shielding against photons, coming from all the sky direction except the field of view and which could also induce background events in the detectors. The phase A study has led to a design completely hermetic to particle straight line trajectories. The active part is made of plastic scintillators, coupled to optic fibers. These optic fibers are read by multi-anode phototubes fixed on the Focal Plane Assembly protective enclosure. The time tag accuracy of each anticoincidence event is better than 50 ns. The passive part is made of a graded shield of similar composition than for the collimator (see 3), and same thickness except for the Tantalum. Indeed, it was found necessary, 3. The collimator and sky shield The function of the system made of the collimator on the detector spacecraft, and the sky shield on the mirror spacecraft, is to prevent out of the field of view photons to reach the focal plane. The collimator should also never screen the field of view. The dimensions of these systems are calculated to fullfill these two constraints, taking into account possible misalignments (lateral and in tilt) as well as movements in all directions due to the formation flight. For mass optimization the collimator is made of three tubes with increasing diametre and decreasing thickness, from the detector end to the mirror end. The shielding of the collimator is composed of successive layers (from outside to inside) of Ta/Sn/Cu/Al/C. The C layer is the inner tube itself. The thickness of the layers are calculated, for each tube, in order to have less than 0.01% of transmission of X-ray photons up to 100 kev, arriving from the sky onto the detectors. As the sky-shield, on the mirror satellite, is covering a very small solid-angle, its opacity to X-rays does not need to be as large as for the collimator. Calculations show that a single layer of Ta is sufficient for ensuring the necessary screening. 4. Data storage and telemetry The three detectors generate events with the following size : 146 bits for the HED 32 + 32 (time tag header, one per line) bits for the LED 29 bits for the ACD The HED and LED data are stored in an on-board mass memory, after treatment in the Event Processing Electronic (EPE). It is not

Laurent et al.: The Simbol-X focal plane 37 Fig. 9. implementation of the collimator above the focal plane assembly. The collimator tube is inside a tower structure which also supports the radio-frequency antennas for the formation flight, and the radiator for the cooling of the imaging detectors. anticipated to download anticoincidence data during normal operations. The interfaces between the detectors electronics and the EPE allows a bit rate of at least 20 Mbits/s, which is not a limiting factor for all astrophysical observations. The mass memory is of at least 32 Gbits. The phase A telemetry capabilities have been sized to ensure : a scientific data download capability of 9 Gbits per orbit (with margin). a scientific quicklook capability of 50 Mbits per contact with the ground. References Chipaux R. et al., 2007, M.Sait, Vol.79, n.1, p.225 Ferrando P. et al., 2007, M.Sait, Vol.79, n.1, p.15 Pareschi G. et al., 2007, M.Sait, Vol.79, n.1, p.22