This FAQ covers the common questions from technicians installing these converters.

Similar documents
This FAQ covers Single Direction use of current loop with transmitting devices.

Universal Converter Covers All the Bases- RS-232 to 4-wire RS-422, 2-wire or 4-wire RS-485

INDUSTRIAL OPTO-ISOLATED RS-232 REPEATER

PRODUCT INFORMATION B&B ELECTRONICS. Port-Powered RS-232 Fiber Optic Modem with Handshake Support. Model 9PFLST. Description. RS-232 Connections

USER MANUAL. MODEL 2017A RS-232 to 20ma Current Loop Converter. SALES OFFICE (301) TECHNICAL SUPPORT (301)

APPLICATION BULLETIN. SERIAL BACKGROUNDER (Serial 101) AB23-1. ICS ICS ELECTRONICS division of Systems West Inc. INTRODUCTION CHAPTER 2 - DATA FORMAT

RS-232 to Current Loop Converters

NETWORK. TE = Terminal Equipment (DTE - Data Terminal Equipment) NT = Network - Terminating Equipment (DCE - Data Circuit - Terminating Equipment)

Miniature Synchronous Multipoint Modems

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

Interface: Serial EIA RS-232D/CCITT V.24, DCE; RTS/CTS delay 0,8 or 64 ms (user-selectable).

RS-232 / 20mA Interface Converter ELO E00Q. Operation manual

1.0 Introduction. Related Products and Documentation

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG MA-12 AC MA-12 DC. Korthållsmodem Short haul modem Kurzstreckenmodem

Concept of Serial Communication

UNICOM 2500 UNICOM Installation Operation Programming. Universal Communication Converter

ZCS485 User s Manual. Version ZYPEX, Inc.

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG MA-19. Korthållsmodem Short Haul Modem Kurzstreckenmodem

Interface converter G kbit/sec

Cable and Port Specifications

Chapter 15: Serial Controlled (HF) Radio Support

INTERNATIONAL TELECOMMUNICATION UNION. SERIES V: DATA COMMUNICATION OVER THE TELEPHONE NETWORK Interfaces and voice-band modems

Part Numbers. Fiber Driver - ST/DB25M FIBER DRIVER

USING RS-232 to RS-485 CONVERTERS (With RS-232, RS-422 and RS-485 devices)

RS-422/RS-485 Line Tester Model 485T

ADA-1028L. User manual ADA-1028L. RS232 to Current Loop 2-wire CLO Converter. 1 io_ada-1028l_v.1.10_en. Copyright CEL-MAR sp.j.

Chapter 12: Digital Modulation and Modems

TD_485 Transceiver Modules Application Guide 2017

This Special Provision covers the requirements for the installation and testing of fibre optic modems (FOM).

Table of Contents. Mounting Diagram.. Wiring Information.. Setting the STR 1000 as a Repeater or a Transmitter. STR 1000 Frequently Asked Questions..

FOM-5A, 6A Asynchronous Fiber Optic Modems

Non-Powered Interface Converters RS-232 to RS-530 RS-422 to V.35 RS-232 to RS-485 RS-232 to RS-422/RS-449

TCSS 372 Laboratory Project 2 RS 232 Serial I/O Interface

INSTALLATIONSANVISNING MD-21 AC INSTALLATION MANUAL REV. A MD-21DC INSTALLATIONS ANLEITUNG

DigiPoints Volume 1. Student Workbook. Module 2 Modem Overview

EIA-232 Information. DTE Signal Direction. DCE Signal Direction. Signal EIA

SMARTALPHA RF TRANSCEIVER

M9606. FSK Modem. 5C Communications Inc.

Multi-Channel RS-232 Serial RF Transceiver

A50/A51/A60. June 2008 (4th Edition) All Rights Reserved

HI 2204LT Loop Powered Level Weight Transmitter OPERATION AND INSTALLATION MANUAL

Integrity Instruments

Serial Input/Output. Lecturer: Sri Parameswaran Notes by: Annie Guo

Modem 1200 baud 500FSD10 EDS500 series - FSK modems

RS-232 Data Acquisition Module 232SPDA and 232SPDACL Document No. 232SPDA3798

Fanuc Serial (RS232) Communications Information

King Fahd University of Petroleum & Minerals Computer Engineering Dept

VC-4/4A, VC-8/8A, VC-16 4/8/16-Channel PCM and ADPCM Voice Modules

DSP4xxFP SA USER S MANUAL. A01561 Rev. A. This Manual covers all configurations of the DSP4xxSA Modem with the Serial Number SA and up.

TECHNICAL NOTES MT-4 Radio Systems TN182 Battery Level Reporting and Remote P25 Test Tone

ICS REPEATER CONTROLLERS

PART 4 DIGITAL METHODS. Chapter 13 Digital Fundamentals. Parallel Data Transfer. Fig Parallel data handshaking

This special provision is for the installation and testing of the following equipment:

Transmission Line Signal Sampling By Don Steinbach, AE6PM

Multi-fiber testing for 40G Ethernet

PRA Series of Radio and TV Amplifier Power Supplies

ANALOG AND DIGITAL PHYSICAL INTERFACES

LBI Installation & Operation

Atrie WireSpan 600/610 MODEM User's Manual

Electronics / Water analogy. Resistor. Inductance. Capacitor. Water Electronics Energy - Energy Pressure - Voltage Flow - Current Volume - Charge

LCM100 USER GUIDE. Line Carrier Modem INDUSTRIAL DATA COMMUNICATIONS

MAINTENANCE MANUAL EUROPEAN LEASE LINE INTERFACE BOARDS 19D904245G1 AND 19D904744G1

SGD 70-A 7 PanelPilotACE Compatible Display

Servo 8 Torque Board Doc V 1.2

CTP2000 4W&EM Interface Module

2070-6A Manual A Manual. Dual 1200 baud Modem For The 2070 Controller GDI A MANUAL

Section 1: Sync only the audio (Zerobeat) Section 2: Sync Radio carriers and Audio

RS 485/422 to Fibre Optic Modems ELO E243, ELO E244, ELO E245. Operation manual

NMEA Protocol Converter 2 Plus 3 Users Guide

CS601 Data Communication Solved Objective For Midterm Exam Preparation

Applications. Operating Modes. Description. Part Number Description Package. Many to one. One to one Broadcast One to many

LDM85. Fiber Optic Modem. Description. Features. Specifications

Microphone audio, from the MFJ-1278B to your transmitter. Ground, audio and PTT common. Push-to-talk, to allow the MFJ-1278B to key your transmitter.

ITL Basics of Encoding and Wiring

Modem RS232/RS422/RS485. to MM optic fibers. RS-232 to Multimode Optic. Fiber Converter. Characteristics DIN rail mounting.

Specifications.

Maintenance Manual ERICSSONZ LBI-31552E

CL4490 HARDWARE INTEGRATION GUIDE VERSION 1.0. FCC Notice.

Using the TB8100 Base Station as a Talk-Through, Community, or Linked Repeater

Installation and Operation Manual HS-R. 4-Channel Low Speed Data Module with V.110 Rate Adaptation MEGAPLEX-2100 MODULE

and WAN Carlos Alberto Avendaño Pérez Medellín-Colombia

Boulder W Class A Stereo Power Amplifier

2070-6B Manual B Manual. Dual 9600 baud Modem For The 2070 Controller. GDI B Manual. Rev B

Arduino Workshop 01. AD32600 Physical Computing Prof. Fabian Winkler Fall 2014

CS601-Data Communication Latest Solved Mcqs from Midterm Papers

Multi-function Gain-Phase Analyzer (Frequency Response Analyzer) Model 2505

AccessCON-N64 INTERFACE CONVERTER E1/FRACTIONAL E1 TO N64 INSTALLATION AND OPERATION MANUAL. Version 1

MD-45 AC MD-45 LV/HV INSTALLATION MANUAL

MDS SD4 Software-Controlled Digital Communications Firmware Release 1.x.x

1995 Metric CSJ SPECIAL SPECIFICATION ITEM Drop/Insert Multiplexor/Demultiplexor

Technician Licensing Class. Lesson 4. presented by the Arlington Radio Public Service Club Arlington County, Virginia

Model RTX-12 Radio Modem

Cable Testing TELECOMMUNICATIONS AND NETWORKING

Week 2 Lecture 1. Introduction to Communication Networks. Review: Analog and digital communications

The Nitty-Gritty of Getting Digital Wired Up At Your Ham Shack

There are many important factors when trying to achieve good, reliable communications between 2 devices.

HR1200. Version 1.00 ATIM RADIOCOMMUNICATION 1/11

Contents. Warranty and Disclaimer 2 Introduction 3

ProLink Radio. 900 MHz SDI-12 Data Radio Scienterra Limited. Version A-0x0C-1-AC 20 October 2009

Interface converter RS-232 / RS-485 TECHNICAL GUIDE. Review date: 9 Jun 2010 TECHNOTRADE LTD

Transcription:

PAGE 1 OF 6 This FAQ covers the common questions from technicians installing these converters. Q: How do I connect the Current Loop Converter to my Current Loop device? A: This Current Loop interface has two states, during the Mark state (no signal), current is flowing in each loop, transmit and receive. In the Space state, no current flows. Open circuit, an Active Current loop will have a DC voltage, a Passive loop will have no voltage. Use a DC voltmeter to measure between T+ and T- to see if a DC voltage is present when the device is turned on, but T+ and T- are open circuit (not connected to anything but the voltmeter). If a DC voltage is present (FIG.1), it will generally be more than 1.2V DC, open circuit may be +5, +12 or more (depending on the Current Source Voltage, but should current limited to around 20mA closed circuit. If the T+ to T- wire pair has voltage, the converter Receive must be connected as a Passive device. If there is no voltage, the converter Receiver must be made Active. Measure and determine whether the device R+ and R- pair is active, if active, the converter Transmitter should be passive. If Receiver is Passive (FIG.2), the Transmit on the converter must be made Active. In the figures which follow, the converter loops are passive, or active or one of each, similar wiring is show for each of the 3 models. Download the data sheets for internal diagrams. Fig. 3: 232CL4R Passive Converter Active Device

PAGE 2 OF 6 Fig. 4: 232CL9R Passive Converter Active Device Fig. 5: 232PCLR Passive Converter Active Device

PAGE 3 OF 6 Fig.6: 232CL4R Active Converter Passive Device To maintain isolation between the RS-232 device and the Current Loop device, a separate isolated power supply should be used to make the Current Loops active. If the Current Loop is made active using the same supply as the RS232 side of the converter, there will be no protective isolation. Fig. 7: 232CL9R Active Converter Passive Device

PAGE 4 OF 6 Fig. 8: Active Converter Passive Device To maintain isolation between the RS-232 device and the Current Loop device, a separate isolated power supply should be used to make the Current Loops active. If the Current Loop is made active using the same supply as the RS232 side of the converter, there will be no protective isolation. Fig. 9: 232CL4R Active Transmit Passive Receive

PAGE 5 OF 6 Fig. 10: 232CL9R Active Transmit Passive Receive To maintain isolation between the RS-232 device and the Current Loop device, a separate isolated power supply should be used to make the Current Loops active. If the Current Loop is made active using the same supply as the RS232 side of the converter, there will be no protective isolation. Fig. 11: 232PCLR Active Transmit Passive Receive When not sending or receiving data, each Current Loop should have around 20mA of current flowing. This can be measured for each loop by connecting a meter with a current scale in series with the Transmit or Receive line, observing meter polarity. In closed loop mode, the voltage drop across the Transmitter will be minimal, depending on the circuits, about 1.8V at the transmitter, around 1.8V at the Receiver.

PAGE 6 OF 6 The RS-232 Connections depend on the type of Device the converter is connected to on the RS- 232 side, if it is a DTE or DCE device. Computer devices are usually DTE, Data Terminal Equipment, Modem devices are DCE. Transmit is an output from a DTE, Receive is an output from a DCE. Devices wired the same must swap the connections for TD and RD. Checking Pin to D: How to identify which of two lines is the output from the device: Use a DC voltmeter, measure from the ground pin to Pin #2 or Pin#3. Usually one Pin from the source device has a minus (-) DC voltage, usually between 11 volts and 3 volts. Whichever lead has a minus voltage should be connected to the TD input pin, Pin #2 on the DB25, (Pin #9 on the 232CL9R) The other pin usually has no voltage or just noise relative to ground. If neither lead has a minus (or positive) voltage on it relative to ground, recheck for OPEN cable connections to the RS-232 device or the device pinouts. If the RS-232 device can be configured multiple ways, make sure all the jumpers and such are set to RS-232. A few devices may use very low power RS-232 ports which switch only between Ground and positive voltage, so to identify which is line is active, the device must be set to transmit data, then tried. Some DC meters may show a slight flicker of DC or AC voltage on a RS-232 data line with changing data. If the Current Loop Device is only sending data (such as a scale), and the Current Loop converter is only receiving, the Transmit data from the device only needs to connect to the Receive inputs on the Current Loop Converter, and Ground and Receive from the Converter to the computer or scale display. This information should help you make the needed connections.