External venetian blinds from Griesser. Lamisol III

Similar documents
Facade awnings from Griesser. Solozip II

Moving Shades. Above : Residential building Product : HunterDouglas Sliding Shutter Screen Special : bronze-tangerine 2 sides combination

Cooper, Robertson & Partners Architecture, Urban Design. Page 1. Daylighting: Flexibility and Conservation

Reflected energy. Winter cold

EFFECTS OF AUTOMATICALLY CONTROLLED BLINDS ON VISUAL

Solar control devices; balance between thermal performance and daylight

Photo info. Product featured in photo above: Floor: Now Lead 6" x 6", 12" x 24"

Reflex-Rol SOLAR GLARE, REFLECTION AND HEAT CONTROL SYSTEMS REFLEX-ROL BLINDS: CONTROLLING SOLAR GLARE, REFLECTION AND HEAT

Shade and Shadow. Lights Dark Brother. Lighting Design is Shade and Shadow. Light and Shadow a unity.

HOME SCIENCE CHAPTER 3: LIGHTING IN THE HOME Class: X

Designer s NOTEBOOK WINDOW PANELS

Light In Architecture

LIGHT MANAGEMENT MASTERED

The decorative side of daylighting Enhanced optical technologies allow designers to use daylight for visual effect

VISUAL STUDIES OF TRANSPARENT PV - ELEMENTS

Venetian Blind System Silent Gliss Silent Gliss Venetian Blind Systems

Design Project. Kresge Auditorium Lighting Studies and Acoustics. By Christopher Fematt Yuliya Bentcheva

Use timers, motion detectors, remote controls, and photocells to reduce waste.

Where to Install Light Shelves

Scandinavian SMART WINDOW 1+2 MSE for commercial and hotel buildings

Venetian Blind System Silent Gliss Silent Gliss Venetian Blind Systems

General Camera Settings

CURTAIN WALL OPTIONS UNITIZED CURTAIN WALL

Bring the Long Life Light Source to the Real Life: LED Lamp. Welcome. OSRAM Prosperity Co., Ltd. Tel : Tel :

Reflections Project Tutorial Digital Media 1

COLOR PALETTE GUIDELINES FOR NON-RESIDENTIAL PROPERTIES

WIDGETS: QUICK and INTUITIVE INTERFACES

Acid etched float glass

Principles of Architectural Design Lec. 2.

markilux Form follows function the conservatory awning with contrasting shapes designed down to the last detail optionally with zip system

Architect: Atelier d architecture Franck Martinez TOGETHER FOR BETTER

Radio Window Sensor and Temperature Sensor Programming in HomeWorks QS

Use of the application program. Functional description. GAMMA instabus Application program description. October 2007

Discover inspiring new possibilities to elevate your art

Use of the application program. Functional description. GAMMA instabus Application program description. May A8 Venetian blind actuator

5.7 Super/hypermarket

German Composite Windows and Doors

Window Parts and Styles

SHADING SYSTEMS AND THE SUPPORT BY DYNAMIC LIGHTING TO IMPROVE LEARNING ENVIRONMENTS THROUGH TWO CASE STUDIES IN DENMARK

Total comfort for every conservatory or patio roof

Decorative Laminated Architectural Glass

OKASOLAR P Glazing with direction-sensitive privacy screening

ALUMINIUM ENTRANCE DOORS ZEN OPEN THE RIGHT ONE

Ronald Reagan Presidential Library. Reagan Country Café

Agus Hariyadi a,b,* and Hiroatsu Fukuda b a. Abstract

Reflection Project. Please start by resetting all tools in Photoshop.

Fading Protection and SageGlass Products

Contact Euroglas GmbH, D Haldensleben Tel.: , Fax:

Solar C - Fixed Solar Shading

Glass in every form. HERO Form

Avery Dennison Architectural Window Films

Silent Gliss Roller Blind Systems

ACRYLITE. for Lighting Technologies

DRAFT V. SITE ELEMENTS SIGNS

Addendum for 2018-COA-486 and 2018-COA-487 for the LeRoux and Cho 77 Projecting signs

DW HORIZONTAL INSTALLATION

Night Vision. Window Film. Low Reflection, View Perfection.

A Study on Performance Evaluation of Mixed Light Shelf Type According to the Angle of Light Shelf

Human Centric Home Lighting. Lighting at the Housing fair in Finland 2016

sedak ceramic-ink printing Printing glass of unique dimensions

architectural Sun control

INSTRUCTIONS FOR INSTALLATION AND SERVICE OF ZF3000 EXTERNAL BLIND

USES AND APPLICATIONS

The Use of Glare Metrics in the Design of Daylit Spaces: Recommendations for Practice

Tivoli Village Villa Refurbishing. Policy, Procedures, and Schedule

Chapter 3¾Examination and Description of Soils SOIL SURVEY MANUAL 73. Soil Color

LAWRENCE PUBLIC LIBRARY ADDITION/RENOVATION creating a new civic hub for the city of lawrence, kansas

Lighting level control of the office room. Technical implementation and daylight modelling of the system

DESIGN GUIDELINES VILLAGEOF KEREMEOS CONTENTS:

Chapter 14. Signage Guidelines 14.2 GENERAL DESIGN OBJECTIVES 14.1 INTRODUCTION AND PURPOSE 14.3 GENERAL SIGN DESIGN GUIDELINES

Design of Intelligent Blind Control System to Save Lighting Energy and Prevent Glare

WASHI INFORMS LIFE - Experience Washi, Architectural Parchment Washi for Interiors Tapestry, Lighting Wall hanging etc

OUTDOOR ROLLER - BLINDS

ABB i-bus KNX Lighting Constant lighting control

The Soft Celiling Luminaire.

LIQUID SOLAR CONTROL. Wiser With Energy

Skylight Shading System Silent Gliss Silent Gliss Skylight Shading Systems

Glass Instalation Guide PRIVA-LITE. Updated v

Technical data lumina MS4/RC

Bulletin Post. Metamerism and Illuminants C O A T S S E W I N G S O L U T I O N S. Contents. Introduction. What is Metamerism? Kinds of Metamerism

NEW! Sivoia QS Wireless Cellular shades. Battery powered, wire-free, remote controlled shades

2015 Feeney (8/15) # D. Aluminum Railing Systems

Overview animeo KNX offer

Properties of Color. Value: Tint: Shade: Tone: Intensity:

Façade INSTALLATION INSTRUCTIONS 03/2014-V1

application software

ABB i-bus EIB Light controller LR/S and light sensor LF/U 1.1

Light In Architecture and Psychology of Light

USES AND APPLICATIONS

Light In Architecture and Psychology of Light

INDEX 1.- LIGHT. DEFINITION 2.- TYPES OF LIGHT

LED APPLICATIONS FOR CUSTOMIZED LIGHTING DESIGNS

DESIGN ELEMENTS INDEX MEDALLIONS 4-5 MONUMENTAL 8-9 CUSTOM TECHNICAL PAGE COLORS SHADOW MOUNT MEMORIAL SIGNS DEDICATION SITE SPECIFIC

NEW! Sivoia QS Wireless Cellular shades. Battery powered, wire-free, remote controlled shades

Designed for Air Traffic Control Towers, the Aviation Shading System from Reflex-Rol

White Paper WP008. Cover. 1/14 1/14 Architectural Precast Applications. Architectural Precast Applications

Cembrit Facade System

Environmental Controls. Daylighting Design. Lecture 15. Design Control Daylighting Overview Daylighting Strategies. Light Flow. Source - Path - Target

OVERVIEW OF SIGN BY-LAW HERITAGE GUIDELINES

CRAFTSMAN. Craftsman Style Guide

Transcription:

External venetian blinds from Griesser. Lamisol III

2 Lamisol III

Lamisol III Lamisol III is available in two versions: as Lamisol III 90 and as Lamisol III 70 for narrow installation conditions. Lamisol III Reflect offers a number of different slat positions in one: The lower blinds zone protects against unwanted glare when working with a monitor, the middle zone ensures beneficial daylight and the upper one directs the light into the interior of the room and creates a pleasant sense of space. This makes the daylight optimally usable in every situation. Lamisol III is available as a MINERGIE module in an automated version. 3 Lamisol III

Self-supporting Built-in system Front mounted system Adjusting cords Two different slat widths Product-Highlights Lamisol III Perforated slats (option) Lamisol III Reflect (option) Operating position (option) 4 Lamisol III

PRODUCT ADVANTAGES IN DETAIL Two different slat widths Lamisol III 90 meets the current installation standard for new buildings Lamisol III 70 is oriented towards the narrow installation situations encountered in renovations and retrofitting. Perforated slats (Option) Perforated slats can be used to provide a better visual link to the outside even when the blinds are closed. This is not recommended for residential applications due to the transparency. Operating position (Option) The shade produced when lowering the blinds is often annoying particularly in the work place. The slat operating position of around 48 degrees prevents the room from getting dark when the blind is lowered. Lamisol III Reflect The Lamisol III Reflect system offers three (Lamisol III 90) or two (Lamisol III 70) different slat positions in one. The lower blinds zone protects against unwanted glare when working with a monitor. The middle zone creates diffuse, beneficial daylight. And the upper zone directs the light into the interior of the room and ensures a pleasant sense of space. Self-supporting The self-supporting blind design protects the insulation in the header and reduces service costs. The system needs no fastening for the housing for widths of up to 2500 mm the insulation remains intact and noise transmission is reduced. Adjusting cords Yellow Kevlar fibers ensure low stretch and shrinkage levels the slat end remains in optimum condition for years. Installation system We offer you the Lamisol III in two different installation versions. One for the header situation and one for the version with a screen. 5 Lamisol III

Our color scheme 6 Lamisol III

OUR COLORS STANDARD COLORS We have created a selection of the most popular colors for you. This has resulted in our five standard colors RAL 7016, RAL 9007/VSR 907, RAL 9006/VSR140, RAL 9010 and RAL 9016. RAL 9006/VSR 140 RAL 7016 RAL 9007/VSR 907 RAL 9016 RAL 9010 PREMIUM COLORS Surface structure Semi-gloss Collection GriColors The colors of our solar shading systems should reflect your wishes, lend distinction to the character of the architecture and create a personal atmosphere. These wishes are a daily challenge to our developers, planners and lacquerers. The variety available for the color selection recognizes practically no limits, given that we have selected 100 color tones the GriColors in addition to the standard colors and divided them into four groups for which nature provided the models. Glass & Stone, Sun & Fire, Water & Moss and Earth & Wood set unique color accents. Collection GriRal Colors Our GriRal color collection has an assortment of 50 different RAL shades of color. From sand yellow to standard white, we offer a complete selection of hues for every color family. We re convinced that with our color palette, you will find exactly the right shade of color for your needs. Surface structure Semi-gloss BiColor External venetian blinds get a new color accent: When bright color is dominant outside, a neutral light can optimize the shading function inside. Create your own preferred color combination using our two color collections, GriColors and GriRal (excluding standard colors). The exterior color shows as a border along the edge of the interior view. Our color recommendations for interior colors: white (VSR 901), light gray (VSR 904) or medium gray (VSR 130). SPECIAL COLORS Color means individuality - there are practically no limits to our Special Colors. No wish goes unanswered with additional innumerable and facade-ready color tones. 7 Lamisol III

Our comfort 8 Lamisol III

CONTROLS Lamisol III can be operated through a variety of control systems, from a simple handheld transmitter to a master control or a building management system, depending on the time, position of the sun and the weather. Thermal comfort The ambient conditions change over the course of the day and during the seasons. With a blinds control device from Griesser, you can adjust your solar shading to match your personal requirements in accordance with changing exterior circumstances. And making these adjustments is so simple that you will still have time to take care of the important things in your life. Reflexion Absorbtion Transmission An optimal daylight concept makes artificial air conditioning superfluous in the summer. You save energy costs and may well also avoid one or another unwanted summer cold. In the winter, on the other hand, a solar shading system can protect you against cold and allow the scarce rays of the sun into the room, thus saving once again on energy costs, not to mention facial tissues. Visual comfort Having a sense of well-being also means being able to decide for oneself, particularly within one s own four walls, just how much one wants to reveal to the outside world. With Lamisol III, you are sheltered from uninvited glances from the outside world. BILINE - REMOTE CONTROL The control system Griesser BiLine provides contemporary design and high functional security through routing technology. Wireless systems have the advantage of being installed quickly, not only in new buildings but also when refitting an automated system in existing buildings. BiLine hand-held transmitter Centrero server for ipad and iphone operation KNX HOME AND BUILDING AUTOMATION The Griesser KNX solar shading controller is an integrated master control with extensive functionalities for any building of any size. With proven functions such as solar tracking and horizon limitation, it meets the highest expectations for solar shading control. KNX controls per ipad 9 Lamisol III

10 Lamisol III

11 Lamisol III

Technology in detail Vertical section: Example of header BUILT-IN SYSTEM bk ca. 100 MBMA+ min. 25 tn min. hl 60 hs p hg min. 10 A B tn min. Top section for crank drive With recess (white) for gearbox (not necessary for motor drive). MBMA+ = Dimension from rear edge of guide rails to center of drive. With gearbox in slat area: hs +20 mm. A dimensional tolerance of ±5 mm is observed for the header height. Top section for crank drive Depth of niche Type tn A B Lamisol III 90 min. 130* 65 65 Lamisol III 70 min. 100* 50 50 * + possible addition for protruding weatherboard or doorknobs. min. 15 min. 20 min. 35 KEY bk = Width of construction hl = Opening height p = Height of package hs = Header height (p + min. 10) hg = Height of gearbox recess (hs -60) tn = Depth of niche All dimensions in mm. 12 Lamisol III

Vertical section: Example with cover BUILT-IN SYSTEM WITH COVER hs p hl min. 10 A B tn min. GUIDE RAILS Embedded guides Type E and F for heat insulation composite systems Type E Type F 25 22 19 40 Type C Type D 22 49 24 26 Type T Type R 44 44 24 45 13 Lamisol III

LIMIT DIMENSIONS bk Width of construction (rear edge of guide rails) Minimum crank drive 510 motor drive 590 Maximum 4500 Buildings and high-rise structures which are exposed to high wind should decrease this maximum value as required (see operating instructions). hl Opening height Minimum 400 Maximum 4300 bk hl Maximum surface area Single blind with crank drive 10 m 2 with motor drive 10 m 2 Connected systems (max. system width 10 m) with crank drive (max. 4 blinds) 10 m 2 A max. of 2 blinds may be connected on each side of the gearbox. with motor drive 2 blinds 16 m 2 3 4 blinds 24 m 2 For 3 or 4 blinds, the motor should be positioned in the center. Header dimensions Opening height (hl) Header height (hs) Lamisol III 90 Lamisol III 70 400 1750 225 235 1751 2000 235 250 2001 2250 250 265 2251 2500 260 285 2501 2750 275 300 2751 3000 290 315 3001 3250 305 330 3251 3500 320 350 3501 3750 330 365 3751 4000 350 385 4001 4300 360 400 Lamisol III Reflect system +5 mm. Header dimensions are approximate values which may exhibit negative or positive deviations depending on the technical circumstances. 14 Lamisol III

LAMISOL III 90 REFLECT WITH 3 ZONES LAMISOL III REFLECT (OPTION) In a modern, computerized work place, protection from glare and heat are of the utmost importance. But losing natural light and the ability to see outside are sacrifices most offices cannot make. Lamisol III Reflect implements a two or three zone system with the option of perforated slats and the correctly angled slats in the various zones. Natural light is put to good use, visibility is preserved, and glare is prevented, all with one product. Only available with motor type E. Glare protection Closed slats in the lower zone provide glare protection. The difference in brightness in the field of vision is thereby reduced to the recommended value (field of vision/ screen max. 3/1). Use of daylight The upper zone with open slats allows daylight to be used. The diagram shows the recommended arrangement for a window with parapets. Clarification is required for the glare protection zone in windows between floors, as is illustrated in the example below. LAMISOL III 70 REFLECT WITH 2 ZONES Example of window with parapet Window with hl 2100 Parapet 800 Zone C (1/3) 700 Height of glare protection (parapet + zone C) 1500 Example of window between floors Window with hl 2700 No parapet Zone C (1/3) 900 Height of glare protection (only zone C) 900 The height of glare protection for the window between floors is clearly too low. Clarification is required for the optimum glare protection zone. A B Glare protection zone (parapet + zone C) C Optimum use of daylight at a modern computerized work place with Lamisol III 90 Reflect, divided into two zones. 15 Lamisol III

Your partner: Subject to change without prior notice. Griesser solar shading - Quality since 1882. www.griessergroup.com V03.15/04.15 2000