WJM POTENTIOMETER TRANSMITTER BEFORE USE... COMPONENT IDENTIFICATION POINTS OF CAUTION INSTRUCTION MANUAL MODEL. (field-programmable)

Similar documents
JPQ2 PULSE ACCUMULATOR

JTY2 PULSE DURATION RECEIVER BEFORE USE... COMPONENT IDENTIFICATION

MODEL: M2DYS SEN TRONIC AG

MODEL: W2DYS SEN TRONIC AG. Mini-MW Series

MODEL: M2SES SEN TRONIC AG [3] OUTPUT

PPD COMPONENT IDENTIFICATION BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PULSE ISOLATOR MODEL. (built-in excitation)

n FRONT PANEL CONFIGURATIONS

NPN TRANSISTOR OUTPUT MODULE

CTC CT TRANSMITTER. (clamp-on current sensor) BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL MODEL CTC

MODEL: M6SXU MODEL: M6SXU [1][2] [3][4]

JRQ2 ENCODER POSITION TRANSMITTER MODEL. Plug-in Signal Conditioners M-UNIT. (field-programmable; built-in excitation)

DISCRETE INPUT MODULE, 16 points

Status Indicator LED PWR LINK COL

MODEL: JB2. Plug-in Signal Conditioners M-UNIT

MODEL: KS. Plug-in Signal Conditioners K-UNIT

User s Manual. Model MXS Universal Computing Unit (1-input, Isolated 2-output Type) MODEL AND SUFFIX CODES

User s Manual. Model MA5 Distributor (Free Range Type) CAUTIONARY NOTES FOR SAFE USE OF THE PRODUCT MODEL AND SUFFIX CODES

MODEL: M2XU MODEL: M2XU [1][2] [3][4]

User s Manual. Model MS5 Potentiometer Converter (Free Range Type) MODEL AND SUFFIX CODES CAUTIONARY NOTES FOR SAFE USE OF THE PRODUCT

MODEL: M6SXT. POWER INPUT DC Power R: 24 V DC

MULTI POWER TRANSDUCER MODEL LSMT4

MODEL: M2VF MODEL: M2VF [1][2] [3][4]

MODEL: M2XPA3. [2] EXCITATION 2: 4 V DC / 20 ma 3: 8 V DC / 20 ma 4: 12 V DC / 20 ma Configurator software is used to change the excitation value.

MODEL: M2EXT. Super-mini Signal Conditioners with Display Mini-M M2E Series

MODEL: W2TS. Mini-MW Series

MODEL: DA3. Plug-in Signal Conditioners M-UNIT

MODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4]

MODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4]

RT-3 UNIT RELAY 4-POINT TERMINAL

MODEL: M1EXT. with Display M1E Series

RT-3 UNIT RELAY 4-POINT TERMINAL

PARM-SIZED, 16-CHANNEL RELAY TERMINALS

MODEL: M5CTC SEN TRONIC AG

MODEL: AS4V. Plug-in Signal Conditioners M-UNIT

SLIM COMPACT SAFETY RELAY

R9CWTU BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL MULTI POWER MONITORING UNIT MODEL. (clamp-on current sensor CC-Link)


Palm-sized, 16-channel Relay Terminals

Slim compact safety relay

30 AMP POWER RELAY WITH SPACE SAVING DESIGN

R7L-YV2. DC VOLTAGE OUTPUT MODULE, 2 points MODEL BEFORE USE... POINTS OF CAUTION COMPONENT IDENTIFICATION INSTRUCTION MANUAL R7L-YV2

TV-15, 30 AMP (1 Form A) Power Relay

CONTENTS. SAFETY PRECAUTIONS: Before use, read the following safety precautions

Electronic circuit protector REX12

OPTITEMP TT 20 Technical Datasheet

AC 24, 110, 120, 230, 240 DC 6, 12, 24, 48 LED indicator with test button G2R-1-SNI (S) G2R-2-SNI (S) Diode

MODEL: JPR2. Plug-in Signal Conditioners M-UNIT

Power supply CP-D 24/4.2 Primary switch mode power supply

User Guide. Ring Modulator - Dual Sub Bass - Mixer

600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet

Modular Video Wall System with Push-to-Pop-out and Anti-Theft Features VW401P. User s Manual

HG RELAYS 20 AMP POWER RELAY FEATURES SPECIFICATIONS

Slim type safety relays. FEATURES 1. Acquisition of Korean safety certification ( S mark) Excluding with diode type

REX12 Electronic Circuit Protector

POWERED MONITOR SPEAKER MSP10STUDIO

Converter. Specifications/Instructions. General. Features. Specifications. Dimensions AB-6484

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure

MODEL: DAST-20. Telemetering System

MODEL: MRP5. Final Control Elements. [2] TERMINAL BOX T: With

20 AMP POWER RELAY HG RELAYS. a HG HG HG Unit weight. Ex. HG 2 AC 240 V

JUMO dtrans T04 Four-wire Transmitter, settable via DIP switch/pc setup program

C 2030 חפר מיכשור ומערכות בע"מ טכנולוגיות לטיפול במים ושפכים מיכשור אנליטי למדידה ובקרת תהליכים OPERATOR'S MANUAL. 2- Wire E.C transmitter Din Rail

POWER AMPLIFIER. Owner s Manual Mode d emploi Bedienungsanleitung Manual de instrucciónes CLIP SIGNAL TEMP PROTECTION POWER

MY-GS CSM_MY-GS_DS_E_2_1

Ratchet Relay. Ordering Information. Unique Ratchet Mechanism Assures Positive Alternate Transfer/Switching Operation. G4Q-jjjj

MODEL: MRP6. Final Control Elements

FR-A7AX FR-A7AX E kit

Installing and Upgrading Internal Modules in Cisco 1800 Series Routers (Modular)

Printing Humidity/Temperature Meter

DVM1190 DIGITAL MULTIMETER

Planar FWMG-MXL INSTALLATION INSTRUCTIONS

Universal flat-panel mount

MODEL: M3LU2. OUTPUT Field-selectable Current 0 20 ma DC Voltage V DC V DC

Load cell system fault finding guide (Application Note: Number AN1)

10-CH Digital Thermometer Module

DIGEM f 96 x 48 EK. Applications. Description

Top spin Nr /

OPERATOR S INSTRUCTION MANUAL

600T Series Transmitters. Specification Sheet. Model 653T Electronic temperature transmitter (PC programmable)

Wireless Room Temperature and Humidity Transmitter (Units without Temperature Setpoint or Override) Installation and Operating Instructions

VECTOR INVERTER -INSTRUCTION MANUAL- 16-BIT DIGITAL INPUT FR-V5AH

CCS Inc. (8) DIN Rail Bracket. 2-M3(inside 3mm max.) for Fixation

MODEL AT-10 ANALOG TRANSMITTER

MODEL: M3LU. OUTPUT Field-selectable Current 0 20 ma DC Voltage V DC V DC

Radio Control Installation and Operating Instructions System 4

Sine Wave Power Inverter GD150/GD300 Series User s Manual

Phase-sequence Phase-loss Relay

REX12 Electronic Circuit Protector

Power supply CP-D 12/2.1

Variable Speed Brushed DC Motor Drive

CEC VIBRATION TRANSMITTER

Relays & Sockets RU Series Universal Relays. With Latching or Momentary Lever. Standard (without lever) Key features:

Switched mode power supply for DIN rail mounting type SMP23 DC24V/40A

Operator's manual TruTool PN 130 (1A1)

PH201G (Style B) Distributor

DISSOLVED OXYGEN TRANSMITTER

This section is specifically about safety matters

G7K. Latching Relay. Compact Mechanical Lock Latching Relays with Manual Buttons. Model Number Structure. Ordering Information

Electronic regulator for PWM controlled proportional solenoid valves FABER -

Power supply CP-D 24/1.3

Transcription:

INSTRUCTION MANUAL POTENTIOMETER TRANSMITTER (field-programmable) MODEL WJM BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below. If you have any problems or questions with the product, please contact M-System s Sales Office or representatives. PACKAGE INCLUDES: Signal conditioner (body + base socket)...(1) MODEL NO. Confirm Model No. marking on the product to be exactly what you ordered. INSTRUCTION MANUAL This manual describes necessary points of caution when you use this product, including installation and connection, hardware setting, and basic maintenance procedures. When you need to change software settings, please refer to the Operation Manual for Model PU-x (EM-955), Section A. COMPONENT IDENTIFICATION Connection Diagram Front Cover Specifications Body Base Socket HOW TO OPEN THE FRONT COVER Position your finger on the hook at the top of front cover and pull. POINTS OF CAUTION POWER RATING & OPERATIONAL RANGE Locate the power input rating marked on the product and confirm its operational range as indicated below: AC power: Rating ±10%, 50/60± Hz, approx. 3.5 VA DC power: Rating ±10%, approx..6 W The shape of base socket may be different for some models. FRONT PANEL CONFIGURATIONS GENERAL PRECAUTIONS Before you remove the unit from its base socket or mount it, turn off the power supply and input signal for safety. ENVIRONMENT Indoor use. When heavy dust or metal particles are present in the air, install the unit inside proper housing with sufficient ventilation. Do not install the unit where it is subjected to continuous vibration. Do not subject the unit to physical impact. Environmental temperature must be within -5 to +55 C (3 to 131 F) with relative humidity within 30 to 90% RH in order to ensure adequate life span and operation. Out. 1 Zero Adj. Out. 1 Span Adj. Out. Zero Adj. Out. Span Adj. Modular Jack Front Cover (open) WIRING Do not install cables close to noise sources (relay drive cable, high frequency line, etc.). Do not bind these cables together with those in which noises are present. Do not install them in the same duct. AND... The unit is designed to function as soon as power is supplied, however, a warm up for 10 minutes is required for satisfying complete performance described in the data sheet. EM-65 Rev.7 P. 1 / 5

INSTALLATION Detach the yellow clamps located at the top and bottom of the unit for separating the body from the base socket. DIN RAIL MOUNTING Set the base socket so that its DIN rail adaptor is at the bottom. Position the upper hook at the rear side of base socket on the DIN rail and push in the lower. When removing the socket, push down the DIN rail adaptor utilizing a minus screwdriver and pull. WALL MOUNTING Refer to EXTERNAL DI- MENSIONS. Clamp (top & bottom) DIN Rail 35mm wide Spring Loaded DIN Rail Adaptor Shape and size of the base socket are slightly different with various socket types. TERMINAL CONNECTIONS Connect the unit as in the diagram below or refer to the connection diagram on top of the unit. EXTERNAL DIMENSIONS unit: mm (inch) CLAMP (top & bottom) 7.8 (.31) 0 (.79) DIN RAIL 35mm wide 8 7 6 5 4 80 (3.15) 4.5 (.18) dia. MTG HOLE 5 (.98) deep 9 3 80 (3.15) 50 (1.97) 107 (4.1) 11 M3.5 SCREW 10 11 1 40 (1.57) 136 (5.35) [3.3 (.13)] 50 (1.97) When mounting, no extra space is needed between units. CONNECTION DIAGRAM POTENTIOMETER max. 3 + 4 5 1 + 1 min. PU-x 1 6 MODULAR JACK 10 11 + 7 8 U(+) V( ) POWER EM-65 Rev.7 P. / 5

CHECKING 1 ) Terminal wiring: Check that all cables are correctly connected according to the connection diagram. ) Power input voltage: Check voltage across the terminal 7 8 with a multimeter. 3 ) Output: Check that the load resistance meets the described specifications. Y(0) (b) : Input Resistance = Actual Resistance Range ADJUSTMENT PROCEDURE This unit is calibrated at the factory with the total resistance input, therefore you do not need any calibration if you use the potentiometer s total resistance. When you don t use the total resistance or in case of regular calibration, adjust the output as explained in the following. Zero and span are adjusted with using the Programming Unit (model: PU-x). Also, fine adjustments can be done with the potentiometers behind the front cover. Refer to the Operation Manual for Model PU-x for explanations how to use the programmer. WARNING ON USE OF THE PROGRAMMING UNIT Be sure to disconnect the Programming Unit before you turn on/off power supply to the unit. The output signal is held when the Programming Unit is connected. You need to disconnect when confirming current output values. HOW TO CALIBRATE THE SIGNAL Use a signal source and measuring instruments of sufficient accuracy level. Turn the power supply on and warm up for more than 10 minutes. Calibrating the Output Range Proportionally to the Actual Input Resistance Range The output range can be calibrated for input ranges narrower than the total resistance, to match the actual input resistance range, by using the linearization table (ITEM 60 through 91) to compensate unused resistance ranges (See the following figures). If upper and lower overranges need not to be considered, only two calibration points will suffice. Y(0) (a), (c) : Unused Resistance = (Total Resistance Input Resistance) (b) : Input Resistance = Actual Resistance Range Y(01) 0% X(01) (b) X(0) Figure. Example of Linearization 1 ) Confirm actual lower-range and upper-range resistance in percentage against the total resistance range 0. In order to do this, provide actual resistance values and confirm them on the Programming Unit (ITEM 05: Input Status Monitor in %). ) Turn the unit into Program mode (ITEM 01). 3 ) Enable use of the linearization table (ITEM 10: Pm- : curved). 4 ) Set the lower-range input in % at ITEM 60. 5 ) Set the lower-range output in %, usually 0 (zero), at ITEM 61. 6 ) Set the upper-range input in % at ITEM 6. 7 ) Set the upper-range output in %, usually 100, at ITEM 63. Table 1 shows an example of settings when you need to use 10 90% of the total resistance and calibrate this range to 0. Table 1. Setting Example ITEM MDFY. DATA DATA EXAMPLE 01 S 1 MTSW : PRG. MODE 60 P 10.00 X (01) : 10.00 61 P 0.00 Y (01) : 0.00 6 P 90.00 X (0) : 90.00 63 P 100.00 Y (0) : 100.00 P: Modifiable only when the MAINTENANCE SWITCH is in the PRG mode. Y(01) 0% X(01) X(0) (a) (b) (c) Figure 1. Unused Resistance EM-65 Rev.7 P. 3 / 5

Fine Output Calibration Using the Programming Unit (ITEM 19, 0) ITEM 19 is for Zero, and ITEM 0 is for Span. 1 ) Turn the unit into Program mode (ITEM 01). ) Apply simulated 0% input. Increase/decrease values (default: 0%) at ITEM 19 until the output signal is calibrated to actual 0%. 3 ) Apply simulated input. Increase/decrease value (default: ) at ITEM 0 until the output signal is calibrated to actual. 4 ) Apply simulated 0% input again and check 0% output. 5 ) When 0% value is changed, repeat the above procedure ) - 4). The 0% value may be shifted when the output span is greater than the input span (gain > 1). Fine Output Calibration via the Front Potentiometers 1 ) ZERO: Apply 0% input and adjust output to 0%. ) SPAN: Apply input and adjust output to. 3 ) Check ZERO adjustment again with 0% input. 4 ) When ZERO value is changed, repeat the above procedure 1) 3). 5 ) Go through the same procedure for the Output. Using Linearization Table Please have the PU-x Operation Manual ready at hand. Max. 16 calibration points defined by sets of input and output values can be programmed. Use only necessary number of points, arranged in order from the smallest input value. Enable use of the linearization table (ITEM 10: Pm-: curved) in order to activate the settings. X (nn) : Input Signal in % Y (nn) : Output Signal in % X or Y : -15.00 to +115.00% + Y05 Y04 ITEM MDFY. DATA EXAMPLE 60 P X (01) : XXX.XX 61 P Y (01) : XXX.XX 6 P X (0) : XXX.XX 63 P Y (0) : XXX.XX 64 P X (03) : XXX.XX 65 P Y (03) : XXX.XX 66 P X (04) : XXX.XX 67 P Y (04) : XXX.XX 68 P X (05) : XXX.XX 69 P Y (05) : XXX.XX 70 P X (06) : XXX.XX 71 P Y (06) : XXX.XX 7 P X (07) : XXX.XX 73 P Y (07) : XXX.XX 74 P X (08) : XXX.XX 75 P Y (08) : XXX.XX 76 P X (09) : XXX.XX 77 P Y (09) : XXX.XX 78 P X (10) : XXX.XX 79 P Y (10) : XXX.XX 80 P X (11) : XXX.XX 81 P Y (11) : XXX.XX 8 P X (1) : XXX.XX 83 P Y (1) : XXX.XX 84 P X (13) : XXX.XX 85 P Y (13) : XXX.XX 86 P X (14) : XXX.XX 87 P Y (14) : XXX.XX 88 P X (15) : XXX.XX 89 P Y (15) : XXX.XX 90 P X (16) : XXX.XX 91 P Y (16) : XXX.XX P: Modifiable only when the MAINTENANCE SWITCH is in the PRG mode. Y03 Y0-15% X01 0 X0 Y01 X03 X04 X05 +115% Figure 3. Linearization Table EM-65 Rev.7 P. 4 / 5

PROGRAMMABLE ITEMS The following items can be monitored and programmed. For detailed explanations, please refer to the Operation Manual for Model PU-x (EM-955), Section A. ITEM MDFY. DATA DISPLAY CONTENTS 01 S MAINTENANCE SWITCH (lock command) 0 MTSW: MON.MODE MONITOR mode: data monitoring only 1 MTSW: PRG.MODE PROGRAM mode: P marked data modifiable 0 P Alphabets & No. TG: XXXXXXXXXX Tag name entry (10 characters max.) 03 05 P D Number (%) No input OUTPER XXX.XX INPPER XXX.XX Output status monitor (%) & simulation output Input status monitor (%) 10 P LINEARIZATION 41 Pm-1: straight Without 4 Pm-: curved With (ITEM 60 to 91 for data input) 19 P Percentage FINZER Fine zero adjustment Initial status shows actual bias (%). When data is entered, output (%) is shown. 0 P Percentage FINSPN Fine span adjustment Initial status shows actual gain (%). When data is entered, output (%) is shown. LINEARIZATION TABLE 60 P Percentage X (01) : XXX.XX Input 1 61 P Percentage Y (01) : XXX.XX Output 1 : : : : : : : : : : 91 P Percentage Y (16) : XXX.XX Output 16 D: No modification (writing) possible. Used only for monitoring (reading). P: Modifiable only when the MAINTENANCE SWITCH is in the PRG mode. MAINTENANCE Regular calibration procedure is explained below: CALIBRATION Warm up the unit for at least 10 minutes. Apply 0%, 5%, 50%, 75% and input signal. Check that the output signal for the respective input signal remains within accuracy described in the data sheet. When the output is out of tolerance, recalibrate the unit according to the ADJUST- MENT PROCEDURE explained earlier. LIGHTNING SURGE PROTECTION M-System offers a series of lightning surge protector for protection against induced lightning surges. Please contact M-System to choose appropriate models. EM-65 Rev.7 P. 5 / 5