AC 01.2 HART Technical data Actuator controls

Similar documents
AC 01.2 Modbus TCP/IP

1-phase AC current Voltages/frequencies Volt Volt 110, 115, , 230, 240 Hz Hz 60 50

1-phase AC current Voltages/frequencies Volt Volt 110, 115, , 230, 240 Hz Hz 60 50

1-phase AC current voltages/frequencies Volt Volt

21 VA (l max 20 5 ms) Connection Cable 1 m, 4 x 0.75 mm 2 Functional data Factory settings Variable Setting Torque Inhibiting torque

Technical data. Parameterisable damper actuator in the

Type 3374 Electric Actuator

Overview of types. Technical data

Power consumption In operation At rest For wire sizing. 150 s / C Sound power level Motor. Emergency setting function 61 db (A)

Operating Manual MU2000K

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool

11 VA Connection Cable 1 m, 4 x 0.75 mm 2 Functional data Factory settings Variable Setting Torque (nominal torque) Motor Spring return

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC 230 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electronic Air / Fuel Ratio Control System

EN 50178, IEC

AMRI is ISO 9001 approved. Direct 1/4 turn electric actuators ACTELEC 3, 6, 12, 25, 50, 100 and 150 Output torques up to 1500 Nm

Technical data. Safety notes. T3-LR24A-SR en v Subject to changes 1 / 2

Smart Power Relay E I...

Simple Sturdy Economical LABEL. Invest in Confidence. Weatherproof Quarter-turn Actuators EZ RANGE

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

TZIF 4. Current-to-Pulse Converter 10/ EN

Servomotor for butterfly valves VF, VFH. delta-elektrogas.com EE157-01/16

Power consumption In operation At rest For wire sizing. Auxiliary switch NRF24A-SR-S2 NRF24A-SR-S2-O

Electric thrust actuator. Electric thrust actuator ARI-PREMIO -Plus 2G. 2,2-5 kn. Electric thrust actuator. ARI-PREMIO -Plus 2G kn.

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

JUMO Wtrans Receiver Universal Receiver for JUMO Wireless Measuring Probes

COMPACT-LINE. KOBO-pH Transmitter for ph-value Model APM-Z

AC/DC 24 V, 50/60 Hz. Functional data Variable Settings. DC V, max. 0.5 ma. End point DC V... 4 ma ma Non-variable

Technical data V phase cut, input impedance 8.2 k Position feedback (measuring voltage U) DC V, max. 0.5 ma Start point DC

Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool

Temperature Input Module for Zone 1 Series 9482/32

Original operating instructions Fail-safe inductive sensor GG507S / / 2013

LED Driver Compact dimming

Simple Sturdy Economical LABEL. Invest in Confidence. Weatherproof Multi-turn Actuators ET RANGE

POINTAX 6000L2 Point Recorder

E l e c t r i c A c t u a t o r s

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

COMPACT-LINE. KOBO-RP Transmitter for ORP Model ARM-Z

PHASED OUT. LED Driver Compact dimming. Driver LCAI 20W 350mA 900mA ECO SR ECO series

PHASED OUT. LED Driver Compact dimming. Driver LCAI 55W 900mA 1750mA ECO C ECO series

MODEL: MRP6. Final Control Elements

Functional data Factory settings Variable Settings

Positioner with HART Communication Type 3780

TAC ATV38, IP55. Variable Speed Drives for Asynchronous Motors. 3-phase. 380/460 V, Hz

2/2 way Proportional Valve (motordriven)

COMPACT-LINE. Transmitter for ph-value

Simple Sturdy Economical LABEL. Invest in Confidence. Weatherproof Quarter-turn Actuators EZ RANGE

EY-EM 527: Remote I/O module, ecolink527

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

ATV12H018F1 variable speed drive ATV kW hp V - 1ph

Original operating instructions Fail-safe inductive sensor GM504S / / 2010

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

BFS / BFSM SERIES Installation & Maintenance Manual

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009

MODEL: MRP5. Final Control Elements. [2] TERMINAL BOX T: With

LED Driver Compact dimming

LED Driver Compact fixed output

Brunata Optuna H Ultrasonic energy meter Type 775 Installation Guide Edition 1.2

2-way motor valve. Power consumption. Type 8746 MFC/MFM. Technical data Materials Body Housing Seals 1) Pressure Range 2) < 1 % FS Sensitivity Span

Industrial actuation made easy

Type CP-S, CP-C & CP-A Switch mode

PHASED OUT. LED Driver Linear / area dimming. Driver LCAI 20W 150mA 400mA ECO lp ECO series

System configuration. Ratings 400 V Class three-phase 90 to 800 kw 690 V Class three-phase 90 to 1000 kw SX-D. Frequency inverters.

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V. Power consumption In operation At rest For wire sizing

Technical Information Barrier RB223

- SMART TUNE- PID CONTROL - UNIVERSAL, 3 WIRE- TC, RTD AND LINEAR INPUT - AUX- REMOTE SET POINT/ TRIM INPUT - 2x ISOLATED CONTROL AND RETRANSMISSION

s Climatix extension module 26 I/Os POL985.00/XXX

Room Temperature Controllers. for heating and cooling systems

T/3000 T/3000. Substation Maintenance and Commissioning Test Equipment

Technical data. Safety notes

SRA 2250/6 RESISTOR ARS-01 RESISTOR AUTOMATICS

Catalogue 1SFC en, Edition 3 November 2003 Supersedes Catalogue 1SFC en, Edition 2 November Arc Guard System TVOC

RMA42. Technical Information

Analog Universal Module HART for Zone 2 Series 9468/33

maxon document number:

Power consumption In operation At rest For wire sizing. 1.5 W at nominal torque 0.4 W 4 VA Connection Cable 1 m, 3 x 0.75 mm 2

PI2794. Flush pressure sensor with display. 1 alphanumeric display 4-digit 2 status LEDs 3 programming button. Made in Germany

ATV12HU22M2. Main. Range of product Altivar 12. Component name Quantity per set Set of 1. Built-in fan. Motor power hp Communication port protocol

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

ATV12HU40M3 variable speed drive ATV12-4kW - 5hp V - 3ph - with heat sink

Spring Return DuraDrive Proportional Actuator

COMMERCIAL. GA Series - Actuator Operating Instructions. GA Non-Spring Return Actuator - (GA24-562) 04/08 /15

Pressure Transmitter SIL

Temposonics. E-Series Model ER. Magnetostrictive, Absolute, Non-contact Linear-Position Sensors. Analog and Start/Stop Outputs.

JUMO Wtrans Receiver with Wireless Data Transmission

SONOMETER TM 1100 Ultrasonic compact energy meter

Brief description. Type overview

TA-Slider 160. Actuators Digitally confi gurable proportional push actuator 160/200 N

Technical Information Nivector FTC968, FTC968Z

Power consumption In operation At rest For wire sizing

DIN Rail Devices. CEAG Sicherheitstechnik GmbH 194

SONOMETER TM 1100 Ultrasonic compact energy meter

Pressure Transmitter Type AKS 32 and AKS 33 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Transcription:

General information AC 01.2 actuator controls for controlling multi-turn actuators of the SA/SAR.2 type range and part-turn actuators of the SQ/SQR type range with interface. Power supply Standard voltages AC: 3-phase AC ages/frequencies 220 230 380 380 400 400 415 440 4 480 0 1-phase AC ages/frequencies 110 120 110 120 220 240 220 240 Special voltages: age >0 V AC are only permissible with external control box. 3-phase AC ages/frequencies 1-phase AC ages/frequencies 220 240 525 575 575 0 6 690 208 Permissible variation of mains voltage: ±10 % Permissible variation of mains voltage: ±30 % (option) Permissible variation of mains frequency: ±5 % Special voltages DC: (on request) DC current ages 24 48 110 125 220 External supply of the electronics (option) Current consumption Overvoltage category Rated power Permissible voltage deviation: (on request) 24 V DC +20 %/ 15 % Current consumption: Basic version approx. 2 ma, with options up to 0 ma External power supply must have reinforced insulation against mains voltage in accordance with IEC 61010-1 and may only be supplied by a circuit limited to 1 VA in accordance with IEC 61010-1. Current consumption of the actuator controls depending on mains voltage: For permissible variation of mains voltage of ±10 %: 100 to 120 V AC = max. 740 ma 208 to 240 V AC = max. 400 ma 380 to 0 V AC = max. 2 ma 515 to 690 V AC = max. 200 ma For permissible variation of mains voltage of ±30 %: 100 to 120 V AC = max. 1,200 ma 208 to 240 V AC = max. 7 ma 380 to 0 V AC = max. 400 ma 515 to 690 V AC = max. 400 ma Category III according to IEC 364-4-443 Actuator controls are designed for nominal motor power, refer to Electrical data pertaining to the actuator Y006.470/003/en Issue 1.17 Page 1/7

Switchgear Control and feedback signals interface with additional input signals (option) Control voltage and current consumption of optional, digital additional inputs Status signals interface with additional output signals (option) Reversing contactors (mechanically and electrically interlocked) for AUMA power classes A1/A2 Reversing contactors (mechanically and electrically interlocked) for AUMA power class A3 Thyristor unit for mains voltage up to 0 V AC (recommended for modulating actuators) for AUMA power classes B1, B2 and B3 The reversing contactors are designed for a lifetime of 2 million starts. For applications requiring a high number of starts, we recommend the use of thyristor units. For the assignment of AUMA power classes, please refer to Electrical data on actuator Via interface Device category: Actuator Analogue 4 20 ma setpoint with digital communication Device category: Current Output Analogue 4 20 ma position feedback signal with digital communication Device category: Actuator : Inputs OPEN, STOP, CLOSE, EMERGENCY, I/O interface, (via opto-isolator thereof OPEN, STOP, CLOSE with one common and EMERGENCY, I/O interface respectively without common) - OPEN, STOP, CLOSE, EMERGENCY control inputs - I/O interface: Selection of control type ( or additional input signals) Device category: Current Output : Inputs OPEN, STOP, CLOSE, EMERGENCY, I/O interface, MODE (via opto-isolator thereof OPEN, STOP, CLOSE, MODE with one common and EMERGENCY, I/O interface respectively without common) - OPEN, STOP, CLOSE, EMERGENCY control inputs - I/O interface: Selection of control type ( or additional input signals) - MODE: Selection between open-close duty (OPEN, STOP, CLOSE) or modulating duty (0/4 20 ma position setpoint) Standard 24 V DC, current consumption: approx. 10 ma per input 48 V DC, current consumption: approx. 7 ma per input V DC, current consumption: approx. 9 ma per input 115 V DC, current consumption: approx. 15 ma per input 100 120 V AC, current consumption : approx. 15 ma per input All input signals must be supplied with the same potential. Via interface Additional, binary output signals (only available in combination with additional input signals (option) - 5 potential-free NO contacts with one common, max. 2 V AC, 1 A (resistive load) Default configuration: End position CLOSED, end position OPEN, selector switch REMOTE, torque fault CLOSE, torque fault OPEN - 1 potential-free change-over contact, max. 2 V AC, 5 A (resistive load) Default configuration: Collective fault signal (torque fault, phase failure, motor protection tripped) - 5 potential-free change-over contacts with one common, max. 2 V AC, 1 A (resistive load) - 1 potential-free change-over contact, max. 2 V AC, 5 A (resistive load) - 6 potential-free change-over contacts without one common, max. 2 V AC, 5 A (resistive load) - 4 mains failure proof potential-free NO contacts with one common, max. 2 V AC, 1 A (resistive load), 1 potential-free NO contact, max. 2 V AC, 1 A (resistive load), 1 potential-free change-over contact, max. 2 V AC, 5 A (resistive load) - 4 mains failure proof potential-free NO contacts, max. 2 V AC, 5 A (resistive load), 2 potentialfree change-over contacts, max. 2 V AC, 5 A (resistive load), All binary output signals must be supplied with the same potential. In combination with device category: Actuator : Analogue output signal for position feedback - Galvanically isolated position feedback 0/4 20 ma (load max. 0 Ω) Y006.470/003/en Issue 1.17 Page 2/7

age output Analogue output (option) Analogue input (option) Local controls Auxiliary voltage 24 V DC: max. 100 ma for supply of control inputs, galvanically isolated from internal voltage supply. Auxiliary voltage 115 V AC: max. 30 ma for supply of control inputs, galvanically isolated from internal voltage supply (Not possible in combination with PTC tripping device) 2 analogue outputs: With position transmitter option: Output of travel and torque as continuous values between 0/4 and 20 ma 2 analogue inputs: With positioner/process controller option: Input of actual position value/actual process value as continuous values between 0/4 and 20 ma Selector switch: LOCAL - OFF - REMOTE (lockable in all three positions) Push buttons OPEN, STOP, CLOSE, RESET - Local STOP The actuator can be stopped via push button STOP of local controls if the selector switch is in position REMOTE. (Not activated when leaving the factory.) 6 indication lights: - End position and running indication CLOSED (yellow), torque fault CLOSE (red), motor protection tripped (red), torque fault OPEN (red), end position and running indication OPEN (green), Bluetooth (blue) Graphic LC display: illuminated Special colours for the indication lights: - End position CLOSED (green), torque fault CLOSE (blue), torque fault OPEN (yellow), motor protection tripped (violet), end position OPEN (red) Bluetooth Communication interface Bluetooth class II chip, version 2.1: With a range up to 10 m in industrial environments, supports the SPP Bluetooth profile (Serial Port Profile). Required accessories: AUMA CDT (Commissioning and Diagnostic Tool for Windows-based PC) AUMA Assistant App (Commissioning and Diagnostic Tool for Android devices) Application functions Selectable type of seating, limit or torque seating for end position OPEN and end position CLOSED Torque by-pass: Adjustable duration (with adjustable peak torque during start-up time) Start and end of stepping mode as well as ON and OFF times can be set individually for directions OPEN and CLOSE, 1 to 1,800 seconds Any 8 intermediate positions: can be set between 0 and 100 %, reaction and signal behaviour programmable Running indication blinking: can be set Positioner - Position setpoint via interface - Automatic adaptation of dead band (adaptive behaviour selectable) - Change-over between OPEN-CLOSE control and setpoint control possible via interface PID process controller: with adaptive positioner, via 0/4 20 ma analogue inputs for process setpoint and actual process value Multiport valve: Up to 16 positions, signals (pulse or edge) Automatic deblocking: Up to 5 operation trials, travel time in opposite direction can be set Static and dynamic torque recording for both rotation directions with torque measurement flange as additional accessory Y006.470/003/en Issue 1.17 Page 3/7

Safety functions EMERGENCY operation (programmable behaviour) - Digital input: Low active (option) - Reaction can be selected: Stop, run to end position CLOSED, run to end position OPEN, run to intermediate position - Torque monitoring can be by-passed during EMERGENCY operation - Thermal protection can be by-passed during EMERGENCY operation (only in combination with thermoswitch within actuator, not with PTC thermistor). Monitoring functions Diagnostic functions Motor protection evaluation Electrical connection Threads for cable entries Wiring diagram (basic version) Local STOP - The actuator can be stopped via push button Stop of local controls if the selector switch is in position REMOTE. (Not activated when leaving the factory.) Interlock for main/by-pass valve: Enabling the operation commands OPEN or CLOSE via interface EMERGENCY Stop push button (latching): interrupts electrical operation, irrespective of the selector switch position. PVST (Partial Valve Stroke Test): programmable to check the function of both actuator and actuator controls: Direction, stroke, operation time, reversing time Valve overload protection: adjustable, results in switching off and generates fault signal Motor temperature monitoring (thermal monitoring): results in switching off and generates fault indication Monitoring the heater within actuator: generates warning signal Monitoring of permissible on-time and number of starts: adjustable, generates warning signal Operation time monitoring: adjustable, generates warning signal Phase failure monitoring: results in switching off and generates fault signal Automatic correction of rotation direction upon wrong phase sequence (3-ph AC current) Electronic device ID with order and product data Logging of operating data: A resettable counter and a lifetime counter each for: - Motor running time, number of starts, torque switch trippings in end position CLOSED, limit switch trippings in end position CLOSED, torque switch trippings in end position OPEN, limit switch trippings in end position OPEN, torque faults CLOSE, torque faults OPEN, motor protection trippings Time-stamped event report with history for setting, operation and faults Status signals according to NAMUR recommendation NE 107: "Failure", "Function check", "Out of specification", "Maintenance required" Torque characteristics (for version with MWG in actuator): - 3 torque characteristics (torque-travel characteristic) for opening and closing directions can be saved separately. - Torque characteristics stored can be shown on the display. Monitoring the motor temperature in combination with thermoswitches within actuator motor Thermal overload relay in controls combined with thermoswitches within actuator PTC tripping device in combination with PTC thermistors within actuator motor AUMA plug/socket connector with screw-type connection Gold-plated control plug (sockets and plugs) Metric threads Pg-threads, NPT-threads, G-threads Device category: Actuator TPCAI000-1A1-A000 TPA00R1AA-0A1-000 Device category: Current Output :TPCAJ000-1A1-A000 TPA00R1AA-0A1-000 Further options for Non-intrusive version with MWG in the actuator Setting of limit and torque switching via local controls Torque feedback signal Wiring diagram (basic version) Via interface Galvanically isolated analogue output 0/4 20 ma (load max. 0 Ω). Option, only possible in combination with output contacts. Device category: Actuator TPCAI000-1A1-A000 TPA00R100-0I1-000 Device category: Current Output : TPCAJ000-1A1-A000 TPA00R100-0I1-000 Setting/programming the interface Setting the address The address is set via command 6 or alternatively via the display of AC 01.2 controls (default value: 0) Y006.470/003/en Issue 1.17 Page 4/7

General interface data Network topology Communication signal cable specification Power supply Device identification Supported commands Point-to-point wiring, baud rate 1.2 kbit/s Device class: "Actuator" FSK (Frequency Shift Key) modulated to 4 20 ma setpoint signal Input impedance: 2 Ω. The impedances of other devices connected (parallel or in series) must be within the specification. Point-to-point wiring Signal range: 4 20 ma Working range: 2 22 ma Minimum operation voltage: 7 V (at 22 ma) Integrated reverse polarity protection Device category: Current Output : FSK (Frequency Shift Key) modulated to 4 20 ma position feedback signal Input impedance: 40 kω. The impedances of other devices connected (parallel or in series) must be within the specification. Point-to-point or multidrop wiring Current output active, short-circuit proof. No further external power supply permitted Refer to specification Internal power supply of interface via actuator controls (apart from supply voltage, no other supply required) Manufacturer name: AUMA Manufacturer ID: 0x7C protocol revision: 7.4 Number of device variables: 12 Model name: AUMATIC AC 01.2/ACExC 01.2 Device type code: 0xE1FD Universal Commands Common Practice Commands: - Command 33 (Read Device Variables) - Command 40 (Enter/Exit Fixed Current Mode) - Command 42 (Perform Device Reset) - Command 45 (Trim Loop Current Zero) - Command 46 (Trim Loop Current Gain) - Command (Read Dynamic Variable Assignments) - Command 79 (Write Device Variable) - Command 95 (Read Device Communication Statistics) Device Specific Commands: - Command 128 (Write Operation Command) - Command 131 (Read Software Version) - Command 132 (Reset to Factory Default) - Command 133 (Reset Operational Data) - Command 134 (Reset Configuration) - Command 1 (Read Parameter) - Command 161 (Write Parameter) - Command 162 (Read Process Data) Y006.470/003/en Issue 1.17 Page 5/7

Commands and signals of the interface Output data Feedback signals Device class: "Actuator" Supported control types: Loop Current Mode activated: Analogue 4 20 ma control signal for position setpoint Loop Current Mode deactivated: Digital commands for position setpoint (0 100.0 %) or for discrete operation in directions OPEN and CLOSE Device category: Current Output : Loop Current Mode activated: Analogue 4 20 ma output signal for position feedback signal (point-to-point wiring) Digital commands for position setpoint (0 100.0 %) or for discrete operation in directions OPEN and CLOSE Loop Current Mode deactivated: Analogue output signal for position feedback fixed to 4 ma (multidrop wiring) Digital commands for position setpoint (0 100.0 %) or for discrete operation in directions OPEN and CLOSE End positions OPEN, CLOSED Position setpoint Actual torque value, requires magnetic limit and torque transmitter (MWG) in actuator Selector switch in position LOCAL/REMOTE Running indication (directional) Torque switches OPEN, CLOSED Limit switches OPEN, CLOSED Manual operation by handwheel or via local controls Analogue (2) and digital (4) customer inputs Device Status Informationen Field Device Status Device Specific Status Extended Device Status Information Standardized Status Analog Channel Saturated Analog Channel Fixed Fault signals Motor protection tripped Torque switch tripped in mid-travel One phase missing Failure of analogue customer inputs Service conditions Use Mounting position Installation altitude Ambient temperature Humidity Enclosure protection according to EN 529 Indoor and outdoor use permissible Any position 2,000 m above sea level > 2,000 m above sea level, on request 30 C to +70 C C to + C, extreme low temperature version Low temperature versions incl. heating system for connection to external power supply 230 V AC or 115 V AC, or internal version 400 V AC. Up to 100 % relative humidity across the entire permissible temperature range IP68 Terminal compartment additionally sealed against interior of actuator controls (double sealed) According to AUMA definition, enclosure protection IP68 meets the following requirements: Depth of water: Maximum 8 m head of water Duration of continuous immersion in water: Maximum 96 hours Up to 10 operations during continuous immersion Modulating duty is not possible during continuous immersion. Pollution degree according to IEC 664-1 Pollution degree 4 (when closed), pollution degree 2 (internal) Y006.470/003/en Issue 1.17 Page 6/7

Service conditions Vibration resistance according to IEC 1 g, from 10 to 200 068-2-6 Resistant to vibration during start-up or for failures of the plant. However, a fatigue strength may not be derived from this. (Not valid in combination with gearboxes) Corrosion protection Coating Colour KS: Suitable for use in areas with high salinity, almost permanent condensation, and high pollution. KX: Suitable for use in areas with extremely high salinity, permanent condensation, and high pollution. Double layer powder coating Two-component iron-mica combination AUMA silver-grey (similar to RAL 7037) Available colours on request Accessories Wall bracket Programming software Torque measurement flange DMF For actuator controls mounted separately from the actuator, including plug/socket connector. Connecting cable on request. Recommended for high ambient temperatures, difficult access, or heavy vibration during service. Cable length between actuator and actuator controls is max. 100 m (Not suitable for version with potentiometer in the actuator). Instead of the potentiometer, the actuator has to be equipped with an electronic position transmitter. (MWG requires a separate data cable.) AUMA CDT (Commissioning and Diagnostic Tool for Windows-based PC) AUMA Assistant App (Commissioning and Diagnostic Tool for Android devices) Accessory for torque measurement for SA/SAR 07.2 SA/SAR 16.2 Further information Weight EU Directives Reference documents Approx. 7 kg (with AUMA plug/socket connector) Electromagnetic Compatibility (EMC): (2014/30/EU) Low age Directive: (2014/35/EU) Machinery Directive: (2006/42/EC) Brochure Electric actuators for industrial valve automation Dimensions Multi-turn actuators with AUMATIC integral controls Dimensions Part-turn actuators with AUMATIC integral controls Y006.470/003/en Issue 1.17 Page 7/7