Tolerance of Dimensions and corner of rectangular wires Standard :DIN R. Tolerance of Dimensions of wire flat S1, B1

Similar documents
Subsidiary of ELSEWEDY ELECTRIC

LS Cable & System Flat Wire and Wrapped Wire

LITZ WIRE 1

2006 2nd International Conference on Power Electronics Systems and Applications

LWW YOUR TOTAL PARTNER FROM THE MINE TO YOUR DOORSTEP

SPECIFICATION FOR APPROVAL. 1/2W, 0603, Low Resistance Chip Resistor (Lead / Halogen free)

High-ohmic/high-voltage resistors

SPECIFICATION FOR APPROVAL. 1/32W, Low Resistance Chip Resistor (Lead / Halogen free)

Z LEAD SURFACE MOUNT SPECIFICATION AC AXIAL CEMENTED WIREWOUND RESISTOR & PR POWER METAL FILM RESISTORS

oéëáåoáåü=ó=fkpri^qflk=póëíéã=ó=`çáäë=ñçê =eáöü=sçäí~öé=j~åüáåéë

Datasheet Platinum Resistance Pt100 In-head (Push Button) Temperature Transmitter TX203P mA output, default range supplied C

Siemens Transformer Technology Seminar Insulation & Thermal Design

Compact Substation or Prefabricated Substation Inside Totally Enclosed Weatherproof Enclosure COPYRIGHT REGISTERED

DUPONT KAPTON POLYIMIDE FILM

All the standards referred to the most current issue, including all amendment supplements. as of the date of the bid.

ABOUT US ABOUT US 1 CRANE CABLES

Sp e c i f i c a t i o n

1 WEAVE Plain. YARN WRAP EC9 430tex ETG 11.6 (tex) WEFT EC9 430tex ETG 11.6

VDM Magnifer Material Data Sheet No August 2000 Edition

Type EP Series. Wirewound Anti-Surge Resistor. Key Features. Characteristics Electrical. Power Derating Curve

8 to 32 AWG Solid Round Copper ranges from to ranges from to C. Polyester/Polyamideimide

REPORT OF PERFORMANCE TIC

SPECIFICATION FOR APPROVAL. 1/8W, 0402, Low Resistance Chip Resistor (Lead / Halogen Free)

Solvent less insulation varnish is based on Unsaturated Polyester resin and consisted of two component system. Tested Items Standard Result Remark

Kerman & Kavian Cable Industries ( KCI )

TPE-INSULATED CABLES TPE-INSULATED CABLES. Products. TPE - Cables HEW-KABEL/CDT

COPPER MAGNET WIRE GP/MR C

(

and cured to reduce hot spots and seal out moisture. The assembly shall be installed on vibration-absorbing pads.

Optical Ground Wires (OPGW)

COMPANY PROFILE... 1 QUALITY CERTIFICATES... 2 APPLICATIONS... 3

GRIP & GRAB ADHESIVE

Electric cables. Cranes

HVR. Lead Wire Length (H, mm)

Transformer Winding Design. The Design and Performance of Circular Disc, Helical and Layer Windings for Power Transformer Applications

RADIALL DETAIL SPECIFICATION FOR SHF COAXIAL CABLE

Selection Guide for Flat Thermally Toughened Soda Lime Silicate Safety Glass

SPECIFICATION FOR APPROVAL 1/8W 0816 LOW RESISTNACE CHIP RESISTOR

WIRE & CABLE. 99 Wire Low fire hazard wire and cable

Standards Update Notice (SUN) Issued: June 6, 2017

High Voltage Thick Film Chip Resistors Product Specification

How to understand MAGNETEC s Datasheet

HO7RN-F 450/750V BS EN Highly Flexible Rubber Cable


!"#$ % &"#$ ,-././ / 0. / / 1 1/ 1 ' !"%!" "&6 7-- (8$&8+. '(')*+,-+-#+.'

HTC Technical Manual

ENERGY CORDAFLEX (SMK) (N)SHTOEU Low Voltage Reeling Cable

HV BOARDS and MUMETAL Integration. Claudio Arnaboldi Tito Bellunato Emanuele Panzeri Gianluigi Pessina (*) INFN Milano Bicocca

Technical specification relevant only to design. Electrical data and diagram. Frequency. Nominal output voltage. Nominal output current

Therma FM, Ltd. is a Czech producer of wound magnetic cores intended for construction of electrical machines.

H155A02. Product Description. Product Specifications. Technical Specifications. Application. Bend Radius. CCB-Sub-Crush Resistance.

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Wire and Cable. 99 Wire Dual Wall 120ºC rated, Modified Polyester Low fire hazard wire and cable. Features & Benefits

Surge Metal Film Leaded Resistor

POLYIMIDE INSULATED WIRES AND CABLES, LOW FREQUENCY, 600V, -200 TO +200 C BASED ON TYPE SPL. ESCC Detail Specification No.

General-purpose Foil Strain Gages (KFGS)

Suflex Astra 703/105. Features. Product Description. Suggested Applications VW-1 Rated Mechanical Tubing

Wirewound/Metal Film Resistors, Commercial Power, Radial Lead

RALEC 旺詮. Scope: 2 (EX) request. IE-SP /01/05. Released Date Page No. Remark. Series. Resistance Tolerance. Nominal Resistance.

Optical Fiber Jelly. PBT loose tube. PE shealth. Aramid Yarn SINGLE MODE OPTICAL FIBER ITU-T REC. G.652D

BCcomponents DATA SHEET. MBA 0204; MBB 0207; MBE 0414 Professional leaded resistors. Product specification File under BCcomponents, BC08.

Enameled Wire Having Polyimide-silica Hybrid Insulation Layer Prepared by Sol-gel Process

Electronic supplementary material

Parkers. Tolerances on dimensions

Y-CY-JZ flexible, CU-screened, transparent, EMC-preferred type, meter marking

CLEAN ENERGY Wind energy cables

HYDROFIRM (T) Cables. for use in Ground Water and Drinking Water

36kV VOLTAGE TRANSFORMERS (OUTDOOR TYPE)

AEC-Q200 Compliant with AEC-Q200 standard. Miniature and light weight. Suit for reflow and wave flow solder

Reactor and inductor are names used interchangeably for this circuit device.

Cold rolling process routes for production of profile wire in copper, copper based and copper coated materials

TECHNICAL SPECIFICATION FOR 11KV, 3C x95mm mm 2 AERIAL BUNCHED CABLES FOR OVERHEAD LINES (CROSSED LINKED POLYTHENE DRY GAS CURED)

Hitachi Magnet Wire. Selection and Use Directions of Magnet Wires

METHODS AND CIRCUITS FOR POWER ARC TEST IN AC CURRENT OF THE SIMPLE AND DOUBLE INSULATOR SETS WITH COMPOSITE MATERIAL FOR AERIAL ELECTRIC LINES

Data sheet. Connection line M12 plug straight - M12 jack straight drag chain suitable, 8-pole, X-coded 2.0 m. Illustrations

Copyright by SpeakerLAB Srl All Rights Reserved Printed in Italy, January 2018

K Factor Power Transformers

BOX TRANSDUCER TYPE CODE DESIGNATION

AEC-Q200 Compliant with AEC-Q200 standard. Miniature and light weight. Suit for reflow and wave flow solder

EPHY-MESS GmbH phone: Berta-Cramer-Ring 1 fax: Wiesbaden Germany

isd dunaferr Product catalogue

DRAWN SEAMLESS ALUMINUM TUBE CAPABILITIES

DATA SHEET GENERAL PURPOSE CHIP RESISTORS RC0603 (Pb Free) 5%, 1%

Low-Pass Filter Designs

FW FW FW FW FW FW FW FW FW FW FW FW

Metallic Bearings. Oiles 500SP1 P.181 Oiles 500SP5 P.206. Oiles 500SPR P.207 Oiles 500HP P.209 Oiles 500B P.213

Instrumentation Cables

OptiLine 45 Floor boxes

Power Resistor, for Mounting onto a Heatsink Thick Film Technology

FEATURES APPLICATIONS DESCRIPTION UNIT HVR25 HVR37. ± 5; E24 series

TECHNICAL SPECIFICATION SHEET

Selection table for flat & ribbon cables

ELCAR T ART. 3/3406 3/3620 PAGINA 1 DI 7. servizio automatico documentazione tecnica T T W H

STANDARD RTD's INDEX

Laser cutting Lamination stacking, welding, and bonding C-5 Coating Finger plates Inspection. A Reliable Resource for Your Business

High Ohmic (up to 33 MΩ)/ High Voltage (up to 3.5 kv) Resistors

CONDITIONS FOR A TENTATIVE APROVAL FOR CONNECTION OF TRANSFORMERS

4 Wire Touch Panel Specification(s)

XXX-X.XXX-.XXX-XX-.XXX X X X

General-purpose Foil Strain Gages KFG

Transcription:

Tolerance of Dimensions and corner of rectangular wires Standard :DIN 46434 R b1 Tolerance of Dimensions of wire flat S1, B1 b1, S1 Tolerance 0.5-3.15 0.03 3.15-6.3 0.05 6.3-12.6 0.07 12.6-16 0.1 Standard: JIS C 3104 standard DIN 46434 Tolerance of radius (corner) of flat wires S1 R Tolerance 1 تا 1/2 S - 1-1.6 0.5-0.65 0.13 1.6-2.24 0.65-0.8 0.16 2.24-3.55 0.8-1 0.2 3.55-5.6 1 0.26 Flat wire as per standard of DIN 4643 S1

Technical specification of copper wire properties of copper Conductivity at 20 C > 58 m/ωmm² Specific resistance at 20 C 0.01724 Ωmm²/m Electrolyze copper Standard ASTMB49 JIS C 3102 E-CUF20 BS6017 JIS 3104 NF A51050 DIN1787 Mechanical characteristic of copper after annealing Round Wire Flat Wire Proof stress RP.0.2 150 N/mm² 100 N/mm² Tensile strength 200-270 N/mm² 200-270 N/mm² Elongation 35% >30% A Technical specification of aluminum wire Standard E - AL AL>99.5% DIN 1712 properties of Aluminum Conductivity at 20 C > 35.5 m/ωmm² Specific resistance at 20 C < 0.02817 Ωmm²/m Mechanical properties of Aluminum wire Proof stress RP 0.2 N/mm² 60 Tensile strength RM 60-100 N/mm² Elongation A >20%

Wire with KAPTON Insulation APPLICATIONS: Transformers (Dry), Generars, Traction Electric Mors STANDARD: IEC 317 IEC 264 Insulation two layers one layer Norminal Dimension of wire properties Thermal class c 0.26 0.38 0.13-0.19 0.1-6 0.15mm(1fi lm) 4Kv 5Kv Polyemid film with Teflon (pfe ) adhesive 0.26 0.38 0.13 0.19 2-88.5mm² Thickness of wire 0.8-5.6 Width of wire 2-16 0.35mm(2fi lm) 8Kv 10Kv Polymide film with Teflon (PFE ) adhesive Rectangular cross

Wire with KAPTON +Doglass or Fiber glass APPLICATIONS: Transformers ( Dry ), Generars, Traction Electric Mors Type if Insulation: one layer Kapn +two layers of Doglass or Fiber GlassKapn + Adhasive Kapn + Lak + 1DGS +1Lack + 3La STANDARD: DIN 46436 DIN 40406 GEN 754101 TUN 901168 Test Standard :DIN 46416 Properties : >5KV Thermal class:c Insulation Nominal Dimension of wire properties Thermal class c 0.26 0.45 0.1-6 > 5 KV PFE Polymide film with Teflon (pfe ) adhesive+ 2 layers of daglass fiberglass 0.26 0.45 2-88.5mm² wire 0.8-5.6 0.35mm(2film ) 8Kv 10Kv PFE Polymide film with Teflon (PFE ) adhesive Rectangular cross Width of wire 2-16

Wire with Doglass-Glass Fiber Insulation This Insulation is used in two ways: Tape Glass-Twisted Glass Fiber-Type Glass APPLICATIONS: These wires are used for the formation of windings for Electric Machines, Apparatus and Instruments, Traction Mors, Dry Transformers etc. STANDARD: DIN 46434 JIS.C 3206, C 3207, C 3104, IEC 2513 Insulation Nominal Dimension of wire properties Thermal Properties class c 0.1-0.4 d 0.9 5.2 0.22-0.3 ( 0.22 ) 0.28 0.32 ( 0.22 ) Side a 1-5 along the side b 2-12.5 0.1-0.4 Thickness 4 a 2.8 10 b 0.4 1.5 KV Glass Fiber Insulation Treated with Silicone Varnish for Adhesion and Impregnation Heat Resistance Enamel Insulation Subsequently Wound Fibers and Impregnated with heat Resistance Varnish Rectangular cross Rectangular cross 0.1-0.4 d 0.8 6 0.1-0.4 d 0.8 6 Glass Fiber Insulation Treated with heatresistance Enamel and Impregnated with heat resistance varnish Fiber Glass,Mechanical Enamel بصورت گرد

Wire with Insulation of MICA POLYESTER + MICA APPLICATIONS: These wires are used for the formation of windings for Electric Machines, Apparatus and Instruments, Traction Mors, Dry Transformers etc. STANDARD: IEC 851 IEC 264 - JIS C3204 One Silk Layer- JIS C3284 One Cotn Layer- JIS C3206 covered with different type Overlap % Insulation class size ( mm ) Properties Thermal class c Round and Flat 33-50 oneالیه and two layers > F Dielectric Ric Strenght V/μm 2 6 mm 0.19 0.85 Mica Mica + Polyester 5 60 mm

Wire with NOMEX Insulation Applications: Transformers (Dry), Generars, Traction Electric Mors STANDARD: BS 4653 IEC 31727 Heat Shock Thickness of Insulation Insulation class size Overlap % Dimension of wire( mm) Rec. wires Cross section Electric al properti es (1 coat) Ther mal class c 33 240 c 0.1-0.4 30 50 66 5-90mm² Thickness ( mm ) 0.8 5.6 Width ( mm ) 2 16t Dielectri c Strenght V/μm 40 C Aramid paper aromatic polyemid Rectangular cross Round Cross section 1.2 6 ( mm )

Wire with Paper Insulation APPLICATIONS : Electric Machine, Apparatus, Transformers, Chock, Oil Transformer STANDARD: DIN 46434 46435 IEC 317-27 BS 4653 Insulation Nominal Dimension of Wire 3P propertie s Therma l class c Based on number of layer is variable. 0.4 6 Based on number of layer is variable F PAPER Round cross - section 30 (mm²) - Min Max 0.14 0.45 30 (mm²) over Min Max 0.45 0.5 2 120 (mm²) Baesd on number of layer is variable F PAPER Rectangular cross