Features Regulated Converters 5W Class II Power Supply in Compact 1 x 1 Package (High Power Density) Internal EMC Class B Filter UL/IEC/EN695-1 certified UL/IEC/EN62368-1 certified Electrical Protection Operating Temperature Range: -25 C to +5 C @ Full Load Description The RAC5-K series are ultra-compact AC/DC power supply modules in lightweight fully-encapsulated plastic casing. Beside safety approvals for industrial and IT solutions UL695-1 and UL62368-1, the units meet EN5532- B limits without any external components. Integrated fusing as well as electrical protections against short circuit and over voltage are on board. With their excellent efficiency over the entire load range including light load standby conditions, these power modules are especially suitable for IOT applications and control equipment. AC/DC Converter RAC5-K 5 Watt 1 x 1 Single Output 3 3 YEAR w a r r a n t y Selection Guide Part Input Output Output Efficiency Max. Capacitive Number Voltage Range Voltage Current typ. (1) Load [VAC] [VDC] [ma] [%] [µf] RAC5-3.3SK 85-264 3.3 1515 76 6 RAC5-5SK 85-264 5 1 8 6 RAC5-12SK 85-264 12 416 81 15 RAC5-15SK 85-264 15 333 82 1 RAC5-24SK 85-264 24 21 84 33 Note1: Efficiency is tested at 25 C with constant resistant mode at full load and Model Numbering Specifications (measured @ ta= 25 C, nominal input voltage (115/23VAC), full load and after warm-up) BASIC CHARACTERISTICS Parameter Condition Min. Typ. Max. Internal Input Filter Input Voltage Range (2) Input Current Inrush Current (refer to line derating graph on PA-3) cold start 23VAC 23VAC 85VAC 12VDC No load Power Consumption 264VAC 75mW Pi Type 264VAC 37VDC 25mA 1mA Input Frequency Range 47Hz 63Hz Start-up Time Rise Time Hold-up time 23VAC Minimum Load % Internal Operating Frequency Output Ripple and Noise Power Factor RAC5- SK Output Voltage 2MHz BW 23VAC 3.3Vout, 5Vout others continued on next page Single Output 6mVp-p.6.45 Note2: The products were submitted for safety files at AC-Input operation. 15A 3A 2s 25ms 12ms 6ms 13kHz 1% of Vout E224736 UL/IEC/EN62368-1 certified UL/IEC/EN695-1 certfied CSA C22.2 No. 695-1-7 certified CSA C22.2 No. 62368-1-14 certified EN6124-3 CB Report REV.: 1/217 PA-1
Specifications (measured @ ta= 25 C, nominal input voltage (115/23VAC), full load and after warm-up) RAC5-K Efficiency vs. Load 1 RAC5-3.3SK 1 RAC5-5SK 9 9 8 8 7 7 6 5 4 3 6 5 4 3 2 1 2 4 6 23VAC 8 1 2 1 2 4 6 23VAC 8 1 1 RAC5-12SK 1 RAC5-15SK 9 9 8 8 7 7 6 5 4 3 6 5 4 3 2 1 2 4 6 8 23VAC 1 2 1 2 4 6 8 1 23VAC 1 RAC5-24SK 9 8 7 6 5 4 3 2 1 2 4 6 23VAC 8 1 PA-2 REV.: 1/217
RAC5-K Specifications (measured @ ta= 25 C, nominal input voltage (115/23VAC), full load and after warm-up) REGULATIONS Parameter Condition Value Output Accuracy Line Regulation Load Regulation Transient Response PROTECTIONS ENVIRONMENTAL Parameter Condition Value Operating Temperature Range with derating (see graph) -25 C to +7 C Maximum Case Temperature 23VAC +75 C Temperature Coefficient Operating Altitude ±.5%/ C Operating Humidity non-condensing 2% to 9% RH Design Lifetime /6Hz and full load at +25 C >1 x 1³ hours MTBF Pollution Degree Vibration Line Derating (3) according to MIL-HDBK-217F, G.B. 25% load step change Recovery Time +25 C +5 C ±1.% typ. ±.5% typ. ±1.% typ. 4.% max. 5µs Internal Input Fuse Short Circuit Protection (SCP) Over Voltage Protection (OVP) Over Current Protection (OCP) Over Voltage Category (OVC) Isolation Voltage I/P to O/P, I/P to Case and O/P to Case tested for 1 minute tested for 3 seconds T1A, slow blow Hiccup, automatic restart 125% - 195%, auto recovery 125% - 195%, auto recovery Isolation Resistance I/P to O/P, Isolation Voltage 5VDC 1GW min. Isolation Capacitance I/P to O/P, 1kHz/.1V 1pF max. Insulation Grade Leakage Current 1 OVC II 3kVAC 4kVAC reinforced.25ma max. 3m >45 x 1³ hours >25 x 1³ hours PD2 1-5Hz, 2G 1min./1cycle, period 6min. each along x,y,z axes Derating Graph (@ Chamber and natural convection.1m/s) 1 Load [%] 9 Output Power [%] 8 6 5 4 2 85 9 Input Voltage [VAC] 264-25 1 2 3 4 5 6 7 8 Ambient Temperature [ C] Note3: No derating required for the specified DC-input range REV.: 1/217 PA-3
RAC5-K Specifications (measured @ ta= 25 C, nominal input voltage (115/23VAC), full load and after warm-up) SAFETY AND CERTIFICATIONS Certificate Type (Safety) Report / File Number Standard Information Technology Equipment, General Requirements for Safety Audio/Video, information and communication technology equipment - Safety requirements Information Technology Equipment, General Requirements for Safety (CB Scheme) Audio/Video, information and communication technology equipment - Safety requirements (CB Scheme) RoHS2 E224736 E49148-A2-CB-1 OFF-478788986-1 UL695-1, 2nd Edition, 214 CSA C22.2 No. 695-1-7, 2nd Edition, 214 UL62368-1, 2nd Edition, 214 CSA C22.2 Nr. 62368-1-14, 2nd Edition, 214 IEC695-1, 2nd Edition + AM2, 213 EN695-1, 1st Edition, 26 + AM2, 213 IEC62368-1, 2nd Edition, 214 EN62368-1, 214 + A11, 217 RoHS 211/65/EU + AM215/863 EMC Compliance Conditions Standard / Criterion Low-voltage power supplies DC output - Part 3: Electromagnetic compatibility EN6124-3:2; Class B ESD Electrostatic discharge immunity test ±8kV Air; ±4kV Contact EN61-4-2:29, Criteria B Radiated, radio-frequency, electromagnetic field immunity test 1V/m, 8MHz-1GHz 3V/m, 1.5GHz-2GHz 1V/m, 2GHz-2.7GHz EN61-4-3:26 + A2:21, Criteria A Fast Transient and Burst Immunity AC In Port: ±2kV EN61-4-4:212, Criteria B Surge Immunity AC In Port (L-N): ±1kV DC Output Port: ±.5kV EN61-4-5:214, Criteria B Immunity to conducted disturbances, induced by radio-frequency fields AC and DC Power Port: 1V EN61-4-6:214, Criteria A Power Magnetic Field Immunity 5Hz, 1A/m EN61-4-8: 21, Criteria A Voltage Dips and Interruptions Voltage Fluctuations and Flicker in Public Low-Voltage Systems <=16A per phase Voltages Dips: >95% Voltage Dips: 3% Interruptions: >95% EN61-4-11:24, Criteria B EN61-4-11:24, Criteria C EN61-4-11:24, Criteria C EN61-3-3:213 DIMENSION and PHYSICAL CHARACTERISTICS Material Package Dimension (LxWxH) Package Weight Case Potting PCB Baseplate continued on next page black plastic (UL94V-) silicone (UL94V-) FR4 (UL94V-) plastic (UL94V-) 25.4 x 25.4 x 16.5mm 2g typ. PA-4 REV.: 1/217
Specifications (measured @ ta= 25 C, nominal input voltage (115/23VAC), full load and after warm-up) RAC5-K Dimension Drawing (mm) 25.4 embossed logo 5 ±1. 5.67 12.7 16.5 25.4 Ø.51 3.13 3.9 Bottom View 1 2 1.29 3 5 1.97 1.84 1.16 11.43 2.7 1. 1.76 2.3 4 Pin Connections Pin # Function 1 VAC in (L) 2 VAC in (N) 3 NC 4 -Vout 5 +Vout NC= no connection Tolerance: xx.x= ±.5mm xx.xx= ±.25mm PACKAGING INFORMATION Packaging Dimension (LxWxH) tube 53. x 27.5 x 25.6mm Packaging Quantity 18pcs Storage Temperature Range non-condensing -4 C to +85 C Storage Humidity 2% to 9% RH The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM s explicit written consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications. REV.: 1/217 PA-5