SECTION ARCHITECTURAL WOODWORK

Similar documents
Solid Surface Countertops

Product Guide Specification

SECTION MANUFACTURED CASEWORK

SECTION ARCHITECTURAL WOOD CASEWORK

FUZION Fused Glass Countertops - Andrew Pearson Design

SECTION Display Case Door Series 1301-CM

SECTION FINISH CARPENTRY PART 1 GENERAL. 1.1 SECTION INCLUDES A. Interior Finish Carpentry Work: 1. Refer to schedule at end of Section.

SECTION ARCHITECTURAL WOODWORK

WHITE W/OAK TRIM NATURAL MEDIUM NORTHPORT OAK

SECTION BULLET- RESISTANT DOORS

Product Guide Specification

Chevy Chase Club June 30, 2008 Bowie Gridley Architects

DIVISION 11 EQUIPMENT SECTION PHOTO DARKROOM FUME EXHAUST VENT-HOODS

Lumicor CSI Specification Guide Open Format Section Solid Polymer Fabrication

Product Guide Specification For Nonrated & 20-Minute Rated Doors

D. Product Certificates: Signed by manufacturers of casework certifying that products furnished comply with requirements.

JEFFERSON LAB TECHNICAL ENGINEERING & DEVELOPMENT FACILITY (TEDF ONE) Newport News, Virginia

Product Guide Specification

Bovard Studios Inc. Section April 6, 2004 Page 1

SECTION PVC THATCH SHINGLE ROOFING SYSTEM PART 1 GENERAL 1.01 SUMMARY

SECTION PRE-MANUFACTURED CABINETS

A. Action Submittals: Written and graphic information that requires Architect's responsive action.

SECTION WIREWAYS FOR RADIOLOGY EQUIPMENT

East Central College

SECTION WOOD ACCORDION FOLDING DOORS

Copyright 2017 AIA MasterSpec Premium 05/17 PRODUCT MASTERSPEC LICENSED BY ARCOM TO WEREVER PRODUCTS, INC.

SECTION SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES

Product Guide Specification

Coordinate installation of rough carpentry members specified in other sections.

Toll-Free

Student Services & Classroom Addition

Music Area Casework General 1.01 Summary Related Sections Definitions Qualifications and Quality Assurance

Solid Surface Fabrications

SECTION WOOD DOORS

2016 Specification Treads, Base, Stringers and other Amenities Wausau Tile Precast Epoxy Terrazzo

A. This section specifies procedural requirements for Shop Drawings, product data, samples, and other miscellaneous Work-related submittals.

SECTION WOOD SHINGLES

A. Interior and exterior non-illuminated tactile building signs including Braille.

SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES

1. Division 6 Section "Rough Carpentry" for furring, blocking, and other carpentry work that is not exposed to view.

Guide Specifications Section

SECTION ARCHITECTURAL WOODWORK. B. Related Sections: 1. Section Paints and Coatings: Field applied painted finishes.

ENDUREED VIVA SERIES Specifications

SECTION SITE FURNISHINGS FOR CFCRT. 1. American Society for Testing and Materials (ASTM).

SECTION COUNTERTOPS ecox PART 1 GENERAL

TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY - PHASE II

GUIDELINE SPECIFICATIONS

B. Shop Drawings: Include elevations, door edge details, frame profiles, metal thicknesses, preparations for hardware, and other details.

SECTION HOLLOW METAL DOORS AND FRAMES

Suggested Specification for Preparing Hot-Dip Galvanized Steel Surfaces for Painting Revised February 2002

ADDENDUM TO THE CONTRACT. for the GLACIER FIRE STATION KITCHEN AND CLASSROOM RENOVATION. Contract No. E16-181

A. Action Submittals: Written and graphic information that requires Engineer's responsive action.

Slate Shingle Specifications

SECTION CUSTOM CABINETS

DIVISION 11 EQUIPMENT SECTION PHOTO DARKROOM CASEWORK

4. Metal roof jacks at penetrations and attachments

St. Monica Food Pantry

Product Guide Specification

.2 Accompany all submissions with a transmittal letter, in duplicate, containing:.4 Specification Section number for each submittal

B. Related Sections include the following: 1. Division 16 Sections for basic electrical and telecom design requirements

DIVISION 6 WOOD, PLASTICS AND COMPOSITES

A. Columns: Worthington Millwork; Cellular Polyvinyl Chloride (PVC) columns; decorative, weatherproof, insect-proof, and highly durable.

SECTION SUBMITTAL PROCEDURES

SPECIAL SPECIFICATION LIGHTNING PROTECTION SYSTEM

DIVISON 6 WOODS AND PLASTICS SECTION PLASTIC LAMINATE FACED ARCHITECTUAL CABINETS

INTEX Millwork Solutions SECTION EXTERIOR PVC PERGOLAS (IBC Compliant)

SECTION SUBMITTAL PROCEDURES

SECTION ARCHITECTURAL WOOD CASEWORK

SECTION LIGHTING PART 1- GENERAL

B. Shop Drawings: For residential casework. Include plans. elevations, details, and attachments to other work.

SECTION SHEET METAL FLASHING AND TRIM

SECTION SLATE SHINGLES. 1.1 SUMMARY A. Section Includes: 1. Slate shingles over underlayment nailed to roof sheathing.

SECTION WOOD ARCHITECTURAL CABINETS AND QUARTZ COUNTERTOPS

EXTERIOR PAINTING

EMMEGI ARCHITECTURAL FENCING MASTER SPECIFICATION SECTION METAL FENCING, GATES & RAILING SYSTEM PART 1 GENERAL

MISSISSIPPI STATE UNIVERSITY Office of Planning Design and Construction Administration

DIVISION 6 WOODS AND PLASTICS SECTION FINISH CARPENTRY

B. Bidders shall acknowledge receipt of this Addendum in writing on his Proposal Form.

UNIFIED FACILITIES GUIDE SPECIFICATIONS

SECTION CUSTOM MILLWORK

C. Installation shall be by experienced carpenters. Coordinate with plumbing and electrical contractors.

SECTION INTERIOR ARCHITECTURAL WOODWORK

FT DIX ELEMENTARY SCHOOL PHASE VII, CLASSROOM ADDITION PEMBERTON TOWNSHIP REGAN YOUNG ENGLAND BUTERA, PC PROJECT #5349A

UCCS University Hall Fire Sprinkler System Upgrade March 1, 2011 RTA SECTION SUBMITTAL PROCEDURES PART 1 - GENERAL

Architecturally Exposed Structural Steelwork (AESS) Sample Specification (for Engineers)

SECTION LAP SIDING. A. Fiber cement lap siding, panels, single, trim, fascia, moulding and accessories.

SECTION FINISH CARPENTRY

Large Scale CalArc Pavers for Sand-Set Pedestrian Use Installations

SECTION WOOD ARCHITECTURAL CABINETS AND LAMINATE COUNTERTOPS

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

SECTION INTERIOR FINISH CARPENTRY PART 1 - GENERAL 1.1 RELATED DOCUMENTS

SECTION CUSTOM CASEWORK

B. Terracotta Precast Facade Assembly consisting of single-leaf, through body color terracotta clay tiles.

SECTION MISCELLANEOUS ROUGH CARPENTRY

SECTION FRAMELESS GLASS SLIDING BI-FOLD SHOWER DOOR HARDWARE

PROJECT LOCATION SECTION PREFINISHED STEEL DOOR FRAMES

B. Section Rough Carpentry: Support framing, grounds, and concealed blocking.

SECTION PLASTIC-LAMINATE-FACED ARCHITECTURAL CABINETS AND COUNTERTOPS

Ash Brook Golf Course Scotch Plains, New Jersey

SHEET METAL FLASHING AND TRIM Christ on the Mountain

Transcription:

SECTION 06 40 00 - ARCHITECTURAL WOODWORK Specifier s Note: This guide allows the specifier to see how the Evo-Lite LumiSheet product may be integrated into a standard specification for architectural woodwork. Unique paragraphs and articles for woodwork specific information must be added to this guide; optionally the paragraphs for LumiSheet may be modified, copied, and pasted as appropriate into specifier s section 06 41 00. PART 1 GENERAL 1 SUMMARY Section Includes: Custom casework. 2. Counter tops. 3. Cabinet hardware. 4. Custom fabricated integral LED lighting panels and accessories. B. Related Requirements: 2. Section 26 05 26: Grounding and Bonding for Electrical Systems. 3. Section 26 05 33: Raceways and Boxes for Electrical Systems. 2 REFERENCE STANDARDS B. Underwriters Laboratories: Provide UL listing for LED lighting panels. C. Illuminating Engineering Society: IES LM79 and LM80. D. International Organization for Standardization: ISO 9001 and 1400 3 SUBMITTALS Comply with Section 01 33 00 - Submittal Procedures. B. Product Data: 2. Submit data on fabricated LED lighting panels. C. Shop Drawings: 2. Indicate locations and dimensions of integral LED panels, including quantity and positions of power adaptors and other accessories. Project Architectural Woodwork Page 1 of 5

D. Samples: 2. Submit sample of LED light panel, x in size, for verification of thickness, color, and visual properties. 4 SUSTAINABLE DESIGN SUBMITTALS 5 QUALITY ASSURANCE B. Comply with ISO 9001 and 14001 for light panel manufacturer facilities. C. Evo-Lite/Fabricator Approved Design: Comply with Evo-Lite Project Certification # indicating that Evo-Lite has reviewed design and product requirements with the woodwork designer/fabricator, and has assigned a project number for the work. This number certifies that LumiSheet is viable for the application and that all components have been approved. 6 QUALIFICATIONS 7 MOCKUP Section 01 40 00 - Quality Requirements: Mockup requirements. B. Construct (partial) (full size) mockup of. Include the following: 2. Integral LED lighting panels of sufficient quantity to demonstrate full effect of backlighting of translucent materials or illumination of woodwork unit. 8 DELIVERY, STORAGE, AND HANDLING Specifier s Note: Following paragraph requires advance review of design with Evo-Lite, but is intended to ensure a complete package of approved components and to simplify detailing. Coordinate product requirements in Part 2 to avoid duplication with Evo-Lite Certification #. B. Deliver all LED light panels with manufacturer s protective film. C. Store LED light panels flat; avoid flexing or bending of panels during handling. Project Architectural Woodwork Page 2 of 5

D. Store LED light panels in dry area and on clean flat surface. Keep panels covered to protect from moisture and dust. E. Maintain LED light panels at 68-77 deg F (20-25 deg C); humidity max. 50%. 9 WARRANTY B. Integral LED lighting panels: Submit manufacturer s standard three-year warranty covering defects in material and workmanship. 10 AMBIENT CONDITIONS PART 2 PRODUCTS 2.1 SUSTAINABILITY CHARACTERISTICS 2.2 CUSTOM CASEWORK Fabricators:. 2.3 MATERIALS 2.4 WOOD TREATMENT 2.5 FABRICATION Specifier s Note: Consider limiting woodwork fabricators to those known to be experienced in integrating electrical or specialty products from other Divisions into architectural casework. B. Shop fabricate LED light panels to greatest degree possible. C. Fabricate integral LED lighting panels to be secured by channels or stops as indicated in shop drawings. Allow for future replacement of panels, if required. Project Architectural Woodwork Page 3 of 5

D. Ensure that LED light panels are not chipped or warped by machining operations. Use cutting and drilling equipment suitable for use with acrylic sheet. E. Do not use adhesive to secure lighting panels or attach other materials to lighting panels. F. Position power adaptors in concealed locations coordinated with electrical services and cord lengths as applicable. Fasten using anchor tabs provided on adaptors and locate to allow for future removal and replacement. 2.6 FINISHES 2.7 ACCESSORIES B. LED lighting panels: Custom fabricated PMMA acrylic sheet with embedded LED lighting strip, integral heat sink, and etched in multiple directions to provide uniform, source-free lighting across panel face. Product: LumiSheet LED Panel: Evo-Lite LLC, Denver, CO (303) 996-2980; www.evo-lite.com. b. No substitutions. c. Provide product with Evo-Lite Project Certification as specified in Part Specifier s Note: Selection of types and quantities of the below and other optional electrical components requires predesign services from Evo-Lite in conjunction with designer and woodwork fabricator. 2. Panel thickness: 8 mm (0.3 inch); thickness tolerance +/- 5 mm (0.0625 inch). 3. Panel dimensions: As shown on shop drawings; dimension tolerance +/- 5 mm (0.0625 inch). Drawing Note: Below thickness is standard unless approved by Evo-Lite for specific application. 4. Panel/LED Color Temperature: Warm White: 3000K. b. Natural White: 4100K. c. Pure/Cool White: 5300K. d. RGB/Color Changing. 5. Ribbon LED strip with integral heat sink embedded in panel edges: Comply with IES LM79 and LM80. b. As designed by Evo-Lite to provide even panel surface brightness. Drawing Note: Locations of power adaptors and dimming controls should be shown in woodwork details. Project Architectural Woodwork Page 4 of 5

C. LED lighting panel electrical components: UL product listing. 2. Dry location rated. 3. Plug-in power adaptors: 4. Hard wire power adaptors: 5. Dimming controls: PART 3 EXECUTION 3.1 EXAMINATION B. Verify locations of utilities associated with work of this Section. Do not install woodwork until electrical devices are properly positioned for connection to LED light panels and power adaptors. 3.2 PREPARATION 3.3 INSTALLATION B. Final connection of hard-wired components is specified in Division 26. 3.4 TOLERANCES 3.5 ADJUSTING 3.6 CLEANING B. Remove strippable film from LED light panels. Clean exposed surfaces in accordance with supplier s and manufacturer s instructions. C. Protect exposed LED light panel surfaces from damage by subsequent construction operations. END OF SECTION Project Architectural Woodwork Page 5 of 5