Special testing of 100 ohm unshielded channel, Class E. Performed for HCS KABLOLAMA SISTEMLERI SAN.VE TIS.A.S.

Similar documents
Qualification testing of 100 ohm shielded channel, Class EA. Performed for Tyco Electronics Raychem N.V.

TEST REPORT. DANAK Reg. no. 19. Electrical performance testing of: Connecting Hardware according to IEC

DELTA Test Report. Certification testing of generic cabling products: Unscreened channel, Class E, 4 connector model. Performed for Sterling

Independent Testing - For End User Confidence

Compass safe distance measurements of Trackball

Performed for LEO Pharma A/S, LEO Innovation Lab

MDS-21 Absorbing Clamp, EZ-24 Ferrite Clamp

DELTA Test Report. Performed for INWIDO Denmark A/S. DANAK 100/2331 Project no.: Page 1 of October 2017

DELTA Test Report. FCC Part 15 C test of Trackman III (TMA3A) Performed for Trackman A/S

AESA TECHNOLOGY OF LAN CABLE

Video Mono Audio Baluns

EFFECT OF SHIELDING ON CABLE RF INGRESS MEASUREMENTS LARRY COHEN

TEST REPORT FROM RFI GLOBAL SERVICES LTD

Electromagnetic Compatibility Test Report FCC test results of an automatic dog brush, model EUT: Type 1 AC/DC adaptor: SYS W2E

Physical Test Setup for Impulse Noise Testing

Independent Testing - For End User Confidence

Video Stereo Audio Baluns

XBee Series 2 OEM RF Module Model No.: XBEE2 FCC ID: OUR-XBEE2. Applicant: MaxStream, Inc. 355 South 520 West Suite 180 Lindon, UT 84042

Test Certificate A sample of the following product received on May 13, 2011 and tested on May 13, 18 and 19, 2011 complied with the requirements of,

FCC PART 15C & RSS 247 TEST REPORT

Report Of. Shielding Effectiveness Test For. DefenderShield. Test Date(s): September 1 October 2, 2012

Coupling/Decoupling Networks (CDN)

Coupling/Decoupling Networks (CDN)

Nemko-CCL, Inc West Alexander Street Salt Lake City, UT

Report for Excelsys EMC Measurements for 4Xgen Purchase Order: Project Number EMT07J026 Rev. B

Combined vibration and temperature test of CX4 Antennas

TRANSMITTER Model: TX24

Client Archive No.: - / - 1 Summary: Table of results: shielding effectiveness measurement: References:...

Methods for Testing Impulse Noise Tolerance

EMC Bayswater Pty Ltd. EMC COMPLIANCE REPORT In accordance with: AS/NZS CISPR 15: Indice Ecotech Pty Ltd. 14W LED Downlight

Report for Excelsys EMC Measurements for 6Xgen Purchase Order: by Project Number EMT08J027

Data sheets CDN-M, CDN-AF, CDN-S, CDN-T, CDN-RJ, CDN-USB

Sunlight Supply, Inc.

FCC CLASS B COMPLIANCE REPORT (DoC)

Shielding Effectiveness Summary Results for RadiaShield Technologies, Inc. RadiaShield Fabric

Measurement of RF Interference from a Canopy 900MHz Access Point and Subscriber Module Using A Yagi Antenna

COMMON REGULATORY OBJECTIVES FOR WIRELESS LOCAL AREA NETWORK (WLAN) EQUIPMENT PART 2 SPECIFIC ASPECTS OF WLAN EQUIPMENT

ER55 EMI TEST RECEIVER Family of automatic test receivers for measurement of electromagnetic interference from 9kHz to 1GHz

Report No.: 063L107-RF-CE-P14V02-2. Test Report. MICRO-STAR INTL Co., LTD. No. 69, Li-De St., Jung-He City, Taipei Hsien, Taiwan, R.O.C.

C E R T I F I C A T I O N

Coupling- / Decoupling Network. 150 khz 300 MHz. 150 khz 230 MHz. 10 khz 230 MHz. IEC and CISPR 15 / CISPR 22 IEC

PDI TEST REPORT. No.0437

TEST REPORT. For ELECTRONICS TECHNOLOGY (DONG GUAN) COMPANY LIMITED EN V9.0.2 ( )

Measuring the EMC on RF-connectors and connecting hardware. Tube in tube test procedure

Measurement of RF Emissions from a Caterpillar Inc. MSS3s RF ID Key Fob

TABLE OF CONTENTS 1.GENERAL INFORMATION PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) TEST STANDARDS TEST METHODOLOGY...4

ENY81 Coupling Network

EN v1.2.1 ( ) TEST REPORT FOR b/g PCIExpress Minicard MODEL NUMBER: AR5BXB63 REPORT NUMBER: 06U

Laird Attn: Bill Steinike W66 N220 Commerce Ct. Cedarburg, WI Report Constructed by: Zach Wilson, EMC Technician Signature: Date: June 21, 2017

1 Introduction Test Specification Environment Relevant standards Emissions Immunity...

C E R T I F I C A T I O N

9 Specifications. Specifications NOMINAL CHARACTERISTICS

ER55 EMI TEST RECEIVER Family of automatic test receivers for measurement of electromagnetic interference from 9kHz to 2.8GHz.

Page 1 of 14 Report No Test Report 2119: EOPENBOX LIMITED. Product: OPENBOX V8S. Commercial-In-Confidence

STC Test Report. Date : Page 1 of 13 No. : HM161169

OUTDOOR SOUND MODULE/TRANSMITTER MODEL: THE BANDIT

FCC PART 15 Subpart C EMI MEASUREMENT AND TEST REPORT

Verification Test Report

Test Report: 5R Champlain Street Dieppe, New Brunswick Canada E1A 1P6. Model Number: Verification

Test Report. Prepared for: Becker Avionics, Inc. Model: TG Description: Aeronautical basestation radio used for emergencies

Date: ESPOO Page: 1 ( 10) Appendices - Transceiver. SATELLINE-EASy Pro 35W SATEL-TA18 SATEL Oy, Finland

Prof. dr. ir. Johan CATRYSSE

CONTENTS 1 GENERAL INFORMATION TEST INFORMATION TEST REPORT SUMMARY TEST RESULTS TEST GRAPHS... 12

TRANSMITTER MODEL: KAS-2030M

UEI FUSION PLUS QWERTY KB REMOTE 2012 MODEL: URC-5110BC0-XXX-R

DELTA Test Report. Type approval testing of C6200 and C6250. Performed for Selco A/S. We help ideas meet the real world

Advanced Test Equipment Rentals ATEC (2832) CNE III Comparison Noise Emitter

RF Emissions Test Report To Determine Compliance With: FCC, Part 15 Rules and Regulations

FCC Test Report. FCC Part 15 Subpart B. Neets A/S. Touch Panel (Touch Panel-7B) 2AM ZKS E. William Liu (Engineer)

R&S CMU-Z10/-Z11 Antenna Coupler/ RF Shielding Cover Simple interference-free testing of all mobiles

EMC of Power Converters

EN v1.2.1 ( ) TEST REPORT FOR n 1X2 PCIe MINICARD TRANSCEIVER MODEL NUMBER: AR5B91 REPORT NUMBER: 08U

EMC ANECHOIC CHAMBERS 5-METER CHAMBERS

Fully Anechoic Room Validation Measurements to CENELEC pren

EMC Test report for LED Panel Light Models , , , , ,

Technical features are subject to change without notice. AUR EL S.p.A does not assume responsibilities for any damage caused by the device s misuse

C-Tick EMC TEST REPORT. For. AC/DC Switching Power Supply

In late 2011, The International Standards

TEST REPORT FROM RADIO FREQUENCY INVESTIGATION LTD.

EMC-PERFORMANCE OF BALANCED (SYMMETRICAL) CABLES

Reducing Motor Drive Radiated Emissions

SGS United Kingdom Ltd. International Electrical Approvals. Electromagnetic Compatibility. RF Card Entry System. PAC International Ltd.

Test Report: 4R Champlain Street Dieppe, New-Brunswick Canada E4P 8L6. Model Number: Verification

TEST REPORT. Power Spout PLT V. tested to the specification. EN : Amendment 1: Electromagnetic compatibility (EMC)

Electromagnetic Compatibility Test Report

TEST REPORT. For RFID READER/WRITER. In conformity with. FCC CFR 47 Part15 Subpart C

Specification for Conducted Emission Test

Test Report. Prepared for: Wilson Electronics, Inc. Model: Description: Dual Band In-Building Signal Booster FCC ID: PWO

MIL-STD 461F Results for M&A Technology Companion epad Computer

TECHNICAL REQUIREMENTS FOR ELECTROMAGNETIC DISTURBANCES EMITTED FROM LIGHTING EQUIPMENT INSTALLED IN TELECOMMUNICATION CENTERS

Company report to support the development of the Ecma MM-EMF technical report (attached pdf-document)

Test Report. Product Name: Wireless 11g USB Adapter Model No. : MS-6826, UB54G FCC ID. : DoC

FCC Part 15 Subpart B

TEST REPORT... 1 CONTENT...

Page 1 of 19 No.: HM TEST REPORT FCC PART 15 SUBPART C CERTIFICATION REPORT FOR LOW POWER TRANSMITTER. TEST REPORT No.

TDS-535 Tuned Dipole Set Operation Manual

Intel Corporation. Corporate Product Regulations. Ferrite Clamp/Tube Analysis CISPR/G/143/CDV. 22 December 1999

N : R2-E JDE :

FCC REPORT. Dongguan Hele Electronics Co., Ltd. J11, J12, J13, Q7, Q28, Q26, Q29

As the responsible EMC Engineer, I hereby declare that the equipment tested as specified in this report conforms to the requirements indicated.

Transcription:

We help ideas meet the real world Test Report DANAK Reg. no. 19 Special testing of 100 ohm unshielded channel, Class E Performed for HCS KABLOLAMA SISTEMLERI SAN.VE TIS.A.S. DANAK-19J1508 Project no.: 312107-2 Page 1 of 9 20 December 2005 DELTA Danish Electronics, Light & Acoustics Venlighedsvej 4 2970 Hørsholm Denmark Tel. (+45) 72 19 40 00 Fax (+45) 72 19 40 01 www.delta.dk This report is issued under the rules of DANAK (Danish Accreditation). Further information about DANAK can be found at www.danak.dk. The report must not be reproduced, except in full, without the written approval of DELTA.

Page 2 of 9 Title Product description Product identification Report no. Special testing of 100 ohm unshielded channel, Class E Category 6 UTP channel Cords: T06-00401-XX (XX designates the length) Horizontal cable: H06-00401 RJ 45 connecting hardware (keystone jack): J6E-00813 (3 pieces) DANAK-19J1508 Project no. N312107-2 Test object received 1 December 2005 Test period 1 December 2005 Client Contact HCS Kablolama Sistemleri San.Ve TIC.A.S. Bankalar Cad. Ekas Han No:75-77 Karakoy Istanbul Turkey Ergun Akan Specification EN 50289-1-6 Results Prepared by Reviewed by Coupling attenuation = 48 db Erik Bech Claude Videt Date 20 December 2005 Responsible Erik Bech, Test Manager DELTA LAN Components and Systems Testing

Page 3 of 9 Table of content Page 1. Summary 4 2. Channel components 5 3. Conclusion 6 4. Test results 7 4.1 Coupling attenuation 7 5. Reference to applicable standards and documents 8 5.1 Cable test standard 8 5.2 Expert contribution for JTC 1/SC 25/WG 3 8 6. Test procedures and equipment 9 6.1 Coupling attenuation 9 6.2 Test software 9

Page 4 of 9 1. Summary One communication channel has been subjected to a test for measurement of coupling attenuation. The channel for this coupling attenuation test was assembled and delivered to DELTA by the client. The channel testing has been performed under laboratory conditions at the European Cabling group of DELTA. This report firstly gives a detailed description of the channels under test. Then the conclusion is given followed by the test results. At last an overview of the test procedures and applied standard are given.

Page 5 of 9 2. Channel components The channel was configured with keystone jacks for the wall outlet and consolidation point in the terminal end. One more keystone jack was used for the connector in the floor distributor end. There were one cord in each end and a length of cable (15 m) between the wall outlet and the consolidation point. A length of horizontal cable in the middle completed the channel. Type designations of the test samples Cords: T06-00401-XX (XX designates the length) Horizontal cable: H06-00401 RJ 45 connecting hardware (keystone jack): J6E-00813 (3 pieces)

Page 6 of 9 3. Conclusion The measured coupling attenuation for the tested channel is 48 db. Below 100 MHz the coupling attenuation is better than 50 db. According to the report: Establishment of the needed electromagnetic performance of generic cabling for compliance with generic cabling (see clause 5.2 for the reference), this performance is adequate with EMC specifications for applications listed below: EMC specifications: Radiated emission EN 55022 class B and FCC part 15 class B Radiated emission EN 55022 class A and FCC part 15 class A Radiated immunity EN 50024 Residential and light industrial areas Applications 1 : 10Base-T 100Base-T 1000Base-T EMC compliance of the complete system is only possible if compliance of the electronic equipment is verified according to the standards with application of unscreened cabling. (This means CE marked in Europe) 1 These applications are investigated in the referenced document. Other applications, which use the lower part of the frequency spectrum may also comply.

Page 7 of 9 4. Test results 4.1 Coupling attenuation 0.0 N312107-02 1. December 2005 Coupling attenuation, channel Measured coupling attenuation 48 db 10.0 20.0 30.0 40.0 db 50.0 60.0 70.0 blue orange green brown Limit 80.0 90.0 100.0 10 100 1000 Frequency Equipment: Network Analyser Hewlett Packard, type 8753E Instrument no.: 31109 Absorbing clamp Rohde & Schwarz, type MDS 21 Instrument no.: 31097 Hybrid MA-COM, type H-1-4 Instrument no.: 31079 Hybrid MA-COM, type H-1-4 Instrument no.: 31080 Hybrid MA-COM, type H-1-4 Instrument no.: 31100 Hybrid MA-COM, type H-1-4 Instrument no.: 31148

Page 8 of 9 5. Reference to applicable standards and documents Test of the channel under test is performed with reference to the following standard: 5.1 Cable test standard CENELEC EN 50289-1-15 Communication cables Specifications for test methods-part 1-15:Electromagnetic performance-coupling attenuation of links and channels. 5.2 Expert contribution for JTC 1/SC 25/WG 3 WG 3 IXT025a, 13 January 2005. Establishment of the needed electromagnetic performance of generic cabling for compliance with generic cabling.

Page 9 of 9 6. Test procedures and equipment The tests carried out on the communication channel under test are performed according to test procedures worked out by DELTA and approved by DANAK. These procedures are as far as possible in compliance with the standardised procedures that are referred in the standards for cabling. 6.1 Coupling attenuation REFLECTOR PLATE, with balun (if applicable) CLAMP 600 ± 10 cm FERRITE, far-end-position at least 100 m total for balanced cables Figure 1 Test set-up for coupling attenuation measurements The coupling attenuation is measured in different parts of the channel using an absorbing clamp. The length of the measured part of the channel under test is 6 m. The measurement result of the network analyser is corrected for insertion loss of the balun and absorbing clamp. The result is also corrected for the reflected wave at the input of the clamp. The result is evaluated by a limit curve, which is horizontal up to 100 MHz and has a slope of 20 db/octave up to 1 GHz. The value for which the limit curve intercepts the Y axis is the coupling attenuation. 6.2 Test software Test software according to information in the table below is used for the conducted tests. Software name Function File name Version Date Cablingtotal Electrical cable tests Cabltot 3.94 050621 DELTA Automatic Reporting Program Automatic word processing Rapport 1.42 050124 Cable report 2002 Cable report generation Cable report 2.8 050823