Pixel sensors with different pitch layouts for ATLAS Phase-II upgrade

Similar documents
Development of Pixel Detectors for the Inner Tracker Upgrade of the ATLAS Experiment

The upgrade of the ATLAS silicon strip tracker

PoS(LHCP2018)031. ATLAS Forward Proton Detector

Silicon Sensor and Detector Developments for the CMS Tracker Upgrade

ATLAS strip detector upgrade for the HL-LHC

A Characterisation of the ATLAS ITk High Rapidity Modules in AllPix and EUTelescope

ITk silicon strips detector test beam at DESY

Silicon Sensor Developments for the CMS Tracker Upgrade

A new strips tracker for the upgraded ATLAS ITk detector

PoS(VERTEX2015)008. The LHCb VELO upgrade. Sophie Elizabeth Richards. University of Bristol

ATLAS ITk and new pixel sensors technologies

The Compact Muon Solenoid Experiment. Conference Report. Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

The LHCb VELO Upgrade. Stefano de Capua on behalf of the LHCb VELO group

arxiv: v1 [physics.ins-det] 6 Feb 2017

PoS(EPS-HEP2017)476. The CMS Tracker upgrade for HL-LHC. Sudha Ahuja on behalf of the CMS Collaboration

Results of FE65-P2 Pixel Readout Test Chip for High Luminosity LHC Upgrades

Upgrade of the CMS Tracker for the High Luminosity LHC

The CMS Silicon Pixel Detector for HL-LHC

CMOS pixel sensor development for the ATLAS experiment at the High Luminosity-LHC

PoS(Vertex 2016)071. The LHCb VELO for Phase 1 Upgrade. Cameron Dean, on behalf of the LHCb Collaboration

Development of n-in-p Active Edge Pixel Detectors for ATLAS ITK Upgrade

The LHCb Vertex Locator (VELO) Pixel Detector Upgrade

The LHCb VELO Upgrade

VELO: the LHCb Vertex Detector

Integrated CMOS sensor technologies for the CLIC tracker

Firmware development and testing of the ATLAS IBL Read-Out Driver card

arxiv: v2 [physics.ins-det] 24 Oct 2012

Strip Detectors. Principal: Silicon strip detector. Ingrid--MariaGregor,SemiconductorsasParticleDetectors. metallization (Al) p +--strips

Layout and prototyping of the new ATLAS Inner Tracker for the High Luminosity LHC

Track Triggers for ATLAS

Silicon Sensors for High-Luminosity Trackers - RD50 Collaboration status report

Prototype Performance and Design of the ATLAS Pixel Sensor

PoS(EPS-HEP 2009)150. Silicon Detectors for the slhc - an Overview of Recent RD50 Results. Giulio Pellegrini 1. On behalf of CERN RD50 collaboration

CMS Tracker Upgrades. R&D Plans, Present Status and Perspectives. Benedikt Vormwald Hamburg University on behalf of the CMS collaboration

Preparing for the Future: Upgrades of the CMS Pixel Detector

The ATLAS tracker Pixel detector for HL-LHC

AIDA-2020 Advanced European Infrastructures for Detectors at Accelerators. Deliverable Report. CERN pixel beam telescope for the PS

A High Granularity Timing Detector for the Phase II Upgrade of the ATLAS experiment

arxiv: v1 [physics.ins-det] 25 Feb 2013

CMS Pixel Detector design for HL-LHC

The Compact Muon Solenoid Experiment. Conference Report. Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

arxiv: v1 [physics.ins-det] 26 Nov 2015

CMS Tracker Upgrade for HL-LHC Sensors R&D. Hadi Behnamian, IPM On behalf of CMS Tracker Collaboration

The CMS Pixel Detector Phase-1 Upgrade

Radiation-hard active CMOS pixel sensors for HL- LHC detector upgrades

Study of the radiation-hardness of VCSEL and PIN

The CMS Pixel Detector Upgrade and R&D Developments for the High Luminosity LHC

The Compact Muon Solenoid Experiment. Conference Report. Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

Studies on MCM D interconnections

10 Gb/s Radiation-Hard VCSEL Array Driver

Test Beam Measurements for the Upgrade of the CMS Phase I Pixel Detector

Development of a Highly Selective First-Level Muon Trigger for ATLAS at HL-LHC Exploiting Precision Muon Drift-Tube Data

The CMS electromagnetic calorimeter barrel upgrade for High-Luminosity LHC


Development of Telescope Readout System based on FELIX for Testbeam Experiments

A High-Granularity Timing Detector for the Phase-II upgrade of the ATLAS Calorimeter system Detector concept description and first beam test results

Attilio Andreazza INFN and Università di Milano for the ATLAS Collaboration The ATLAS Pixel Detector Efficiency Resolution Detector properties

`First ep events in the Zeus micro vertex detector in 2002`

The CMS Silicon Strip Tracker and its Electronic Readout

Richard L. Bates SUPA, School of Physics and Astronomy, Glasgow University, Glasgow, G12 8QQ, UK

The VELO Upgrade. Eddy Jans, a (on behalf of the LHCb VELO Upgrade group) a

PoS(Vertex 2016)049. Silicon pixel R&D for the CLIC detector. Daniel Hynds, on behalf of the CLICdp collaboration. CERN

The INFN R&D: new pixel detector for the High Luminosity Upgrade of the LHC

The ATLAS Insertable B-Layer Pixel Detector

Towards a 10 μs, thin high resolution pixelated CMOS sensor system for future vertex detectors

Expected Performance of the ATLAS Inner Tracker at the High-Luminosity LHC

CMOS Detectors Ingeniously Simple!

Julia Thom-Levy, Cornell University, for the CMS Collaboration. ECFA High Luminosity LHC Experiments Workshop-2016 October 3-6, 2016

Understanding the Properties of Gallium Implanted LGAD Timing Detectors

Thin Silicon R&D for LC applications

Sensor production readiness

Aging studies for the CMS RPC system

Phase 1 upgrade of the CMS pixel detector

arxiv: v2 [physics.ins-det] 13 Oct 2015

PoS(VERTEX 2009)037. The LHCb VELO Upgrade. Jianchun Wang 1

ATLAS Tracker and Pixel Operational Experience

Experience with the Silicon Strip Detector of ALICE

The LHCb Silicon Tracker

CMS SLHC Tracker Upgrade: Selected Thoughts, Challenges and Strategies

The LHCb Upgrade BEACH Simon Akar on behalf of the LHCb collaboration

PoS(TIPP2014)382. Test for the mitigation of the Single Event Upset for ASIC in 130 nm technology

PoS(Vertex 2016)020. The ATLAS tracker strip detector for HL-LHC. Kyle Cormier. University of Toronto

AIDA Advanced European Infrastructures for Detectors at Accelerators. Journal Publication

Fluence dependence of charge collection of irradiated pixel sensors

arxiv: v2 [physics.ins-det] 15 Feb 2013

STUDY OF THE RADIATION HARDNESS OF VCSEL AND PIN ARRAYS

ATLAS Phase-II Upgrade Pixel Data Transmission Development

R&D for ILC detectors

Performance of a Single-Crystal Diamond-Pixel Telescope

What do the experiments want?

The Silicon Vertex Detector of the Belle II Experiment

ATLAS Upgrade SSD. ATLAS Upgrade SSD. Specifications of Electrical Measurements on SSD. Specifications of Electrical Measurements on SSD

Pixel characterization for the ITS/MFT upgrade. Audrey Francisco

Edge Characterization of 3D Silicon Sensors after Bump-Bonding with the ATLAS Pixel Readout Chip

ATLAS Upgrade SSD Project:

Resistive Micromegas for sampling calorimetry

CMOS pixel sensors developments in Strasbourg

The LHCb VELO Upgrade

Construction and Performance of the stgc and MicroMegas chambers for ATLAS NSW Upgrade

arxiv: v2 [physics.ins-det] 15 Nov 2017

Transcription:

Pixel sensors with different pitch layouts for ATLAS Phase-II upgrade Different pitch layouts are considered for the pixel detector being designed for the ATLAS upgraded tracking system which will be operating at the High Luminosity LHC. The tracking performance in the Endcap pixel regions could benefit from pixel layouts which differ from the geometries used in the barrel region. Also, the performance in different barrel layers and eta regions could be optimised using different pixel sizes. This presentation will report on the development and tests of pitch layouts which could be readout by the FE-I4 ASICs. The pixel geometries include 50 250 µm 2, 25 500 µm 2, 100 125 µm 2, 125 167 µm 2, 50 2000 µm 2 and 25 2000 µm 2. The sensors with geometries 50 250 µm 2, 25 500 µm 2 and 100 125 µm 2 were irradiated and tested at the DESY testbeam. These and other testbeam results as well as results from characterisation of these sensors in the laboratory will be presented. Technology and Instrumentation in Particle Physics 2014, 2-6 June, 2014 Amsterdam, the Netherlands Speaker. c Copyright owned by the author(s) under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike Licence. http://pos.sissa.it/

1. Introduction In approximately 2024, the Large Hadron Collider (LHC) will be upgraded to the High Luminosity LHC (HL-LHC). The upgrade is foreseen to increase the LHC design integrated luminosity by a factor ten. The ATLAS [1] experiment will need to build a new tracker for HL-LHC operation, which needs to be suited to the harsh HL-LHC conditions in terms of particle rates and radiation doses. In order to cope with the increase in pile-up backgrounds at the higher luminosity, an all-silicon sensor detector is being designed. The baseline layout [2] for the pixel upgrade forsees the sensors on the inner barrel layers to be readout by a new chip, with a pixel size of 50 50 µm 2, and the sensors on the outer barrel and endcap layers/disks to be readout by the FE-I4 chip [3] with a pixel size of 250 50 µm 2. In order to study the pitch of the inner barrel layer, 500 25 µm 2 and 125 100 µm 2 geometry sensors can be used. The 500 25 µm 2 geometry is also investigated for use for the higher eta regions on the outer barrel layers, where the increased incidence angle will increase the cluster size for the normal 250 50 µm 2 sensor. Square modules (125 100 µm 2 and 167 125 µm 2 ) are being investigated for the endcap where demands on the φ and r resolution are very different from the barrel. 2. Sensors In partnership with Micron Semicondutor Ltd [4], we have developed various wafers of pixel detectors. The CERN pixel V wafer was designed to study different pixel geometries. The different pixel geometries on the CERN pixel V wafer are: 125 100 µm 2 (square) with 26880 pixels, 167 125 µm 2 (square) with 15680 pixels, 250 50 µm 2 (current baseline for outer barrel pixel layers) with 26880 pixels, 500 25 µm 2 (elongated) with 26880 pixels, 2000 25 µm 2 (strixel) with 6720 pixels and 2000 50 µm 2 (strixel) with 3660 pixels. The CERN pixel V wafer also contains sensors with both DC and AC coupling to allow future performance studies comparing the two options. They have been produced with thickness of 300µm, 200 µm, 150µm and 100µm. The results presented here are for sensors with DC coupling and thickness of 300µm and have a full depletion voltage of 80V. The sensors under test were bump bonded to FE-I4 chips at Advacam [6] 3. Test Beam Results The DESY test beam consisted of 4 GeV positrons [7]. The tracking was performed by the ACONITE beam telescope (a copy of the EUDET beam telescope [8]). The Devices Under Test (DUTs) are mounted inbetween the two arms of the telescope). Only two DUTs were mounted due to the multiple scattering of the 4GeV beam. The sensitive elements of the telescope planes are Mimosa26 [9] active pixel sensors with a pixel pitch of 18.4 µm. Each plane consists of 1152 576 pixels covering an active area of 21.2 10.6mm 2. The tracking resolution is estimated to be 2µm [10]. The trigger was provided by four scintillators (two up and two down stream of the telescope), which resulted in an effective sensitive area of 2 1cm 2. The trigger rate was 1kHz. The hit efficiency was measured by matching hits on the sensors to a matching track in the telescope. 2

Various comparisons were carried out, for example between the 250 50 µm 2 and the 500 25 µm 2 non-irradiated sensors, and between non-irradiated and irradiated sensors. The irradiations were carried out at the Birmingham irradiation facility [5], to a fluence of 1 10 15 1MeV n eq cm 2. The results will be presented in the following sub-sections. 3.1 Comparison between the 250 50 µm 2 sensor vs 500 25 µm 2 sensor Tracks are generated when there are at least 4 out of 6 hits in the telescope planes and at least one in the DUT. Tracks extrapolated from telescope match to a hit if the hit and extrapolated impact point on the DUT containing the hit are closer than 400 µm in the long direction and 150µm in the short direction. The hit efficiency for both sensors was shown to be uniform over their area and greater than 99.5%, for both thresholds studied (3200e and 1600e). Figure 1 shows the measured residuals for the 250 50 µm 2 and the 500 25 µm 2 devices at a threshold of 3200e; in x (long pixel direction) the distribution is flat and centred on zero with the RMS value well approximated by pitch/ (12) (for the 500 25 µm 2 device we expect 144.3 µm and 7.2 µm in x and y. And for the 250 50 µm we expect 72.2 µm and 14.4 µm in x and y). In y the residual is improved by the smaller pixel size. Figure 1: The measured residuals in x (left) and y (right) for the 250 50 µm 2 and the 500 25 µm 2 devices at a threshold of 3200e. Figure 2 shows that there is a small difference in the maximum time over threshold as measured for the 250 50 µm 2 and the 500 25 µm 2 devices at a threshold of 1600e and 3200e, due to the difference in tuning and the effect of the different cluster size. Figure 3 shows the cluster size in x and y for the two devices. It is clearly seen that there is negligible change in the cluster size in going from the 250 50 µm 2 and the 500 25 µm 2 in x, whilst there is an increase in the charge sharing in the y when going from 50 to 25 µm. 3.2 Comparing a 125 100 µm 2 non-irradiated device with an irradiated one (1 10 15 ) The modules were glued down onto low mass 400µm thick carbon fibre plates to reduce multiple scattering but still provide an efficient cooling path. The cooling was provided by dry ice (module temperatures were -25 C). Figure 4 shows the hit efficiency for the non-irradiated (100V bias voltage, its full depletion voltage is 80V) and irradiated sensor (500V bias voltage, 3

Figure 2: The maximum time over threshold as measured for the 250 50 µm 2 and the 500 25 µm 2 devices at thresholds of 1600e and 3200e. Figure 3: The cluster size in x (left) and y (right) as measured for the 250 50 µm 2 and the 500 25 µm 2 devices at thresholds of 1600e and 3200e. with a full depletion voltage of 600V). As can be seen the efficiency is better than 99 ± 0.03 % and is uniform over the sensor. The irradiated sensor has more masked channels (10% of the channels compared to 1% for a non-irradiated sensor). Figure 5 shows the hit efficiency, with a threshold of 2000e, as a function of bias voltage (excluding masked pixels). As expected we get full efficiency for the non-irradiated module, but we need a higher bias voltage for the irradiated sensor. Inner pixel efficiency is also of interest as we have the punch through bias for the pixels at the edge. The efficiency of a pixel is plotted using the extrapolated hit position. All hits are plotted across the smallest repeatable regular structure which is four pixels. Figure 6, shows this for the 125µm 100µm sensor. All hits are then folded into a single pixel which is represented by the green box in Figure 6. As a result the punch through bias structure will be replicated twice. The method of folding used means that punch through bias structures will be in the right side corners of the inner pixel efficiency plots. Any drop in efficiency in the left side is due to charge sharing between the corners of the pixel implants. As expected the efficiency for the non-irradiated module is high, 99.9 ± 0.03 % at 100V. Where as the efficiency changes with bias voltage for the irradiated sensor, Figure 7. Inefficient regions due to charge sharing between neighbouring pixels quicly 4

Figure 4: The efficiency map for the non-irradiated (left) and irradiated (right) 125 100 µm 2 modules at 100 and 500V respectively. Figure 5: The hit efficiency as a function of bias for the non-irradiated (red) and irradiated (blue) 125 100 µm 2. disappears, while the inefficient region due to the punch through biasing structures only decreases in size. Figure 6: A schematic of four pixels, showing the bias dot in the middle. 3.3 Comparing a 250 50 µm 2 non-irradiated sensor with an irradiated one (1 10 15 ) These modules were tested in the same maner as the 125 100 µm modules. The overall efficiency for the non-irradiated module was 99.99 ± 0.03 % at 100V and 99.32 ± 0.03% at 500V 5

Figure 7: The inner-pixel hit efficiency as a function of bias (from left to right, 200V, 300V, 400V and 500V) for the irradiated 125 100 µm 2. for the irradiated module. Figure 8 shows the efficiency as a function of bias voltage for the two sensors. Figure 8: The hit efficiency as a function of bias for the non-irradiated (red) and irradiated (blue) 250 50 µm 2. The resolution within pixel s results were similar. For the non-irradiated module it is 99.99% at 100V, whereas the irradiated modules efficiency changes as a function of bias voltage, Figure 9. The effect of the punch through biasing can be seen on the right side of the pixel. 4. Summary Pixel sensors with geometries that include 50 250 µm 2, 25 500 µm 2, 100 125 µm 2, 125 167 µm 2, 50 2000 µm 2 and 25 2000 µm 2, have been fabricated by Micron. These have been bump bonded to FE-I4 readout chips. Some of them have been irradiated to 1 10 15 n eq cm 2 and then tested in test beams at DESY with 4GeV electrons. The tracking efficiency has been shown to be excellent in all cases. References [1] G. Aad et al, The ATLAS experiment at the CERN Large Hadron Collider, JINST 3 (2008) S08003. [2] Letter of Intent for the Phase-II Upgrade of the ATLAS Experiment, Technical Report CERN-LHCC-2012-022. LHCC-I-023, CERN, Geneva, 2012. [3] M. Garcia-Sciveres et al., The FE-I4 pixel readout integrated circuit, Nucl. Instr. Meth. A636, S155-S159 (2011). 6

[4] Micron Semiconductor Ltd., http://www.micronsemiconductor.co.uk [5] P. Dervan et al, The Birmingham Irradiation Facility, Nucl. Instr. Meth. A730, 101-S104 (2013). [6] www.advacam.com [7] http://adweb.desy.de/home/testbeam/www/description.html [8] A. Bulgheroni et al., Results from the EUDET telescope with high resolution planes, Nucl. Instr. Meth. A623, 399-401 (2010). [9] C. Hu-Guo, A ten thousand frames per second readout MAPS for the EUDET beam telescope, CERN-2009-008. [10] J. Behr, Jets at high Q 2 at HERA and Test Beam Measurements with EUDET Pixel Telescope, Dissertaion and Ph.D thesis (2010) - ZEUS, Universitat Hamburg, Chapter 16. 7

Figure 9: The inner-pixel hit efficiency as a function of bias (from top to bottom, 100V, 200V, 300V, 400V and 500V) for the irradiated 250 50 µm 2. 8