Mounting Accessories. Installation Guide. VIVOTEK SD83XXE Speed Dome

Similar documents
Outdoor Enclosure. VIVOTEK Pan/Tilt & Fixed Dome Series. Installation Guide

Extender Conduit Box. VIVOTEK Fixed Dome Series. Installation Guide. Using AM-712 conduit box, AP-FXC-0200 PoE Extender, and compatible accessories

Wall-mount Bracket. VIVOTEK Fixed Dome & PTZ Series. Installation Guide. IP Sur veillance. Using AM-215 wall-mount bracket and compatible accessories

Wall-mount Bracket. VIVOTEK Fixed Dome & PTZ Series. Installation Guide. IP Sur veillance. Using AM-215 wall-mount bracket and compatible accessories

Installation Instruction

TOOLS REQUIRED Metal Wood Wood and Metal Screws. #16 Drill #12-24 Tap. 1/8 Drill

MantelMount. TM1A Installation Instructions IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS

TITAN2-EDGE Public Access Computer Station Dual Track

Installation and Assembly - Universal Articulating Swivel Double-Arm for 42" - 60" Plasma Screens

Dublin Stalls Installation Instructions

33/35A Series. Devices covered by these instructions: Rim Exit Device. CD33/35A Rim Exit Device EL33/35A Rim Exit Device SS33/35A Rim Exit Device

Fixed Wall Arm. Installation Guide. Part number Rev E 2012 PolyVision Corporation All rights reserved

Installation and Assembly - Universal Articulating Swivel Double-Arm for 42" - 60" Plasma Screens

Installation Instructions for: Saris Cycle Aid. Saris Cycle Air. Saris Cycle Air HD

96 (Standard Length)

OB1U INSTALLATION INSTRUCTIONS. Interactive Flat Panel Over White Board Mount

INSIDE PANEL NOT SHOWN TO DETAIL ANCHORING SYSTEM

ASSEMBLY AND ADJUSTMENT

Ready To Go SimpleSpec tm. Installation Manual. For more information, please visit 3-form.com or call

DETAILED ILLUSTRATION

MAG-CONV Basic, 48, 48R & Midline Front Mount

Installation Instructions

This instruction manual is an in-depth look and explanation of how to assemble and install the Murphy Bed properly and efficiently.

INSTALLATION INSTRUCTIONS

BIKE FILE (301)

EDGE2 DUAL MONITOR ARM

Kiosk Solution W1000. Installation and Assembly Instructions July 2015 Edition

ED1300/1300F SERIES CONCEALED VERTICAL ROD DEVICE INSTALLATION INSTRUCTIONS

Kwik-Lock. Installation Instructions. Attention Dealers: Please give this owners manual to the customer when the product is delivered.

Workbench Instructions for Assembly

SB-WM-ART1-M-BL. Weatherproof Universal Single-Arm Articulating Mount for Medium Displays INSTALLATION MANUAL

How To Measure Your Finished Opening

GENUINE PARTS INSTALLATION INSTRUCTIONS

11 6 Round Building Assembly Instructions

Equilibrium. Conference Table. Installation Instruction. Revision B 11/07/16

12x12 Pavilion. Assembly Manual

Preference Collection and Treatment Console INSTALLATION GUIDE

Clearview Railing System Installation Instructions

ALL SEASON PATIO COVER

Heavy Duty Ceiling Tilt Mount Installation Manual

SB-WM-ART2-L-BL SB-WM-ART2-XL-BL

Face Mount to Through-the-Post Mount

D3976 RECESSED EXIT INSTALLATION INSTRUCTIONS

TABLE OF CONTENTS REQUIRED TOOLS

For all Davis weather consoles including Vantage Pro2,

Footer & Base Plate Assembly. installation guide. ILINE power/data beam

Installation and Assembly - Articulating Swivel Double-Arm for 42" - 71" Plasma Screens

SM-RAZOR-ART2-L / SM-RAZOR-ART2-XL

Sentinel Electronic Safe Installation Guide

IDR assembly instructions:

A500 ASSEMBLY & INSTALLATION INSTRUCTIONS

PRO / PL SHOE REPLACEMENT & CONVERSION INSTRUCTIONS

Original Gallery System

ELPMB27. Short Throw Projector Wall Mount Installation Manual xxx(fr) xxx(de) xxx(it) xxx(es) xxx(pt) xxx(zhs)

v1.0 ASSEMBLY GUIDE Mia Wide Bookcase

aluminium profile system

Lid, Floor Monument and Two Installation Fixtures. Floor Monument Installed with Lid On and Off

SECTION 7. SAFETYING

ASSEMBLY GUIDE. Mia Narrow Bookcase

INSTALLATION INSTRUCTIONS

Installation and Assembly: Flat Video Wall Mount For 40" to 65" Flat Panel Displays

Deck Mount Installation with Bench

INSTALLATION GUIDE. Model:B60 RECESSED IN WALL MOUNT

LX Sit-Stand Wall Mount Keyboard Arm

MM750 Installation Instructions

Privacy Wall & Glass Selections Pivot-Hinged Door (For products manufactured after September 14, 2009)

WASP Extended Shuttle Fitting. Process Overview

On-Roof Mounting Sets for Flat-Plate Collectors

Installation and Assembly: Full Service Video Wall Mount

BLADE N BULLET BLIND Cabela s Item Number:

Preference Collection 5580 Treatment Console INSTALLATION GUIDE

Oxford Stalls Installation Instructions

COYOTE Terminal Closure (Single Chamber) Hermetically Sealed With Hardened Adapters

BL-ER-P Ethernet Radio Unit for Pedestal Installation Guide

installation guide ICON classic benching

Leveling Feet, Base Plates and Casters

MAKO TM CASH DISPENSER

33/3547A. Special tools needed: #10-24 tap Drill bits: #25, 5/16, 13/32, 1/2

MTS-ZB. RENOGY Photovoltaic Module Z-Bracket Mounting System E Philadelphia St, Ontario, CA Version: 1.

Strata. urniture. Adriana Instructions. Parts in the Arm Box: Parts in the Body Box: Watch our assembly videos at

MONOPRICE. Above Fireplace Pull-Down Full-Motion TV Wall Mount. User's Manual P/N 27773

Assembly Instructions Nevins Phone Booth

INSTALLATION INSTRUCTIONS FOR FRONT CASTING DECK RAIL Ranger

CAB END BEDTRAX (SIDE VIEW)

19 to 39 TV WALL MOUNT - FULL MOTION

Independent Containment System (ICS)

User Instructions Multiline Otter Scoreboard Caddy Assembly

PowerLock. Installation Instructions. Attention Dealers: Please give this owners manual to the customer when the product is delivered.

Ford Pick Up Rear leaf Spring Kit Installation Instructions

Jenny Legs Assembly Instructions

Leafy Greens Spinner Construction Manual

B-Too Drilling and Tapping Machine Instruction and Maintenance Manual

GlideRite Retractable Cover System For HotSpring & Tiger River Spas (except Classic & pre-2000 Landmark Spas)

How to Install Custom Real Wood and Faux Wood Blinds

Hawko LED Flex & Accessories Installation Instructions

Articulating TV/Monitor Wall Mount Model: WA300S (Butterfly Series)

BISON GOOSENECK FOOTBALL 1 PAIR OF GOAL POSTS

Custom 3-Point Seatbelt Installation Guide for: Corvette

RELINER INSIDE DROP SYSTEM SPECIFICATIONS

MTS-SP100. RENOGY Pole Mount System E Philadelphia St, Ontario, CA Version: 1.2

Transcription:

VIVOTEK SD83XXE Speed Dome Mounting Accessories AM-116/117 Pendant Pipe AM-118 Pendant Head AM-221 Gooseneck AM-231 Parapet Mount AM-519 Pendant Adaptor Installation Guide Corresponding part numbers: AM-116: AM-117: AM-118: AM-221: AM-231: AM-519: 900014300G 900014400G 900014600G 900014800G 900015000G 900014900G Rev. 1.1 IP Sur veillance

Revison History: Rev. 1.0: Initial release Rev. 1.1: Adding corresponding ordering part numbers and supported speed dome models. I Compatible VIVOTEK Cameras Speed Dome SD8364E, SD8363E, SD8333E, SD83x4E, SD83x6E, SD8362E II Mechanical Drawings AM-118 Pendant Head 2

AM-116 20cm Pendant Pipe AM-117 40cm Pendant Pipe English AM-519 Pendant Adapter (comes with the network camera) 3

AM-221 Gooseneck AM-231 Parapet Mount 4

AM-231 Parapet Corner Mount English 5

AM-231 Parapet Mount - Alignment Sticker AM-231 Corner Mount - Alignment Sticker 6

III Preparation before Installation English Connect Ethernet cable and IO wires (this may include the AC24V wires) to the interface section of the camera, and then combine the interface section with the dome cap. Note that you must route cables through the waterproof connector and the rubber seal plug, and install them to the dome cap. Please refer to the Quick Installation Guide for details. Cabling should be done before mounting the camera. 2 The top section will look like this. 1 7

IV Mounting & Cabling IV-1. Pendant Pipe Mounting: AM-116/-117 & AM-118 Shown below are the dimensions of a pendant mount configuration using the 40cm pendant pipe. AM-118 AM-117 446.2 mm AM-519 321.4 mm 204.8 mm 8

IV-1-1. Pendant Mount without Pendant Pipe: AM-118 English Below are the sample procedures using a pendant head and pendant pipe: 1. Determine a hard surface ceiling location, and use the alignment sticker to mark the positions where holes will be drilled to secure the pendant head. Hammer the anchors into the ceiling. Note that mounting holes should be 10mm in diameter and 60mm deep. The included screws are M6.2 x75mm. 2. Install a pendant adapter (AM-519) by turning it clockwise to the pendant head, and secure the connection using an included 3mm hex wrench. AM-519 9

3. Route power lines and other wires through the pendant head. You may apply a 1 inch conduit. 4. Secure the pendant head to ceiling by driving screws through its mounting holes. Depending on the length of your cables, you may need the help from your colleague for holding the camera top section. Cables Pendant Head Camera top section 10

5. Secure the camera's top section to the pendant head by fastening 3 M5x8 screws. When done, secure the connection using an included 3mm hex wrench. English 6. Install the camera to the top section. See your Quick Installation Guide or page 15 for details. 11

IV-1-2. Pendant Mount with Pendant Pipe: AM-116/AM-117 & AM-118 Below are the sample procedures using a pendant head and pendant pipe: 1. Determine a hard surface ceiling location, and use the alignment sticker to mark the positions where holes will be drilled to secure the pendant head. Hammer the anchors into the ceiling. Note that mounting holes should be 10mm in diameter and 60mm deep. The included screws are M6.2 x75mm. 2. Install a 20cm or 40cm pendant pipe (AM- 116 or AM-117) by turning it clockwise to the pendant head, and secure the connection using an included 3mm hex wrench. 12

3. Route power lines and other wires through the pendant head. You may apply a 1 inch conduit. 4. Secure the pendant head to ceiling by driving screws through its mounting holes. Depending on the length of your cables, you may need the help from your colleague for holding the camera top section. English Cables Pendant Head Camera top section 13

5. Secure the camera's top section to the pendant head by fastening 3 M5x8 screws. 6. Install the camera to the top section. See your Quick Installation Guide or page 15 for details. 14

IV-2. Gooseneck Mounting: AM-221 English Below is a sample procedure using a gooseneck bracket: 1. Determine a hard surface wall location. Use the alignment sticker to mark the positions where holes will be drilled for the gooseneck bracket. 2. Drill 4 pilot holes (10mm in diameter and 5.5cm deep) into the wall, and then hammer in threaded anchors. Note that you should hammer the anchors with hex nuts on them so that the threaded poles will not be deformed! If preferred, drill another hole for routing cables. 3. Secure the wall mount bracket to wall using 4 sets of lock washers and nuts. 4. Attach the top section (dome cap and interface section) of the camera to the gooseneck bracket 2 3 1 Install AM-519 adaptor to the gooseneck. 5. Align the camera body with the top section. Align the alignment mark on the camera with that on the interface section. Push the camera up to match the top section. 4 5 HD WDR Pro Alignment mark 15

HD WDR Pro HD WDR Pro 6. Rotate the camera clockwise until its alignment mark is aligned with the "C" mark. 7. Use the included T25 stardriver to tighten the 3 anti-tamper screws from the top. Make sure all parts have been securely tightened. 7 6 C mark The dimensions of the gooseneck installation are shown below. 16

IV-3. Parapet Mounting: AM-231 English The screws included in the parapet set are: Sleeve anchors 5/16" x3" 6 Hex bolts M8x25 6 Hex bolts M8x70 3 Hex lock nuts M8 6 Washers M8 15 Lock washers M8 15 IMPORTANT: The parapet bracket is designed for installation on the inside of a parapet. Note the following before you start to install: 1. There must be a clearance of 65mm between the upper edge of the parapet wall and the metal bracket fixed to the wall. You can flush align the upper edge of the alignment sticker with the edge of a parapet wall. 2. At least two inches of space should be available below the parapet bracket for routing cables. The space requirements for a parapet mount are shown below: The parapet wall should have a concrete strength of 4000 PSI or higher. Each sleeve anchor can withstand an 800kgs pull-out force. Parapet Side view Front view Room for routing cables 17

Below is a sample procedure using the parapet mount bracket: 1. Determine a hard surface location. Use the alignment sticker to mark the positions where holes will be drilled for the bracket. 2. Drill 6 pilot holes (10mm in diameter and 5.5cm deep) into the wall, and then hammer in the sleeve anchors. Note that you should hammer the anchors with hex nuts and washers on them so that the threaded poles will not be deformed! 3. Install the brackets to wall using the hex nuts and washers from the sleeve anchors. Parapet wall 18

NOTE: English If you install the corner parapet bracket, use the included alignment sticker, and mark the drill holes through the mounting slots on the brackets. 19

4. Use a crescent wrench to secure the outer brackets to the brackets on the wall using the M8x25 hex bolts and washers. Do not completely tighten the bolts yet! When the speed dome is installed to the mount pipe, it needs to be swiveled out to the desired position. 5. Install the AM-519 adapter to the parapet pipe. 6. Feed cables through the pipe arm. The cable length for passing through the pipe arm is 250cm at least. You can pass a rigid copper wire through the pipe arm first, and use it to pull other wires through the pipe. 20

7. Install the top section of the camera to the pipe arm by driving 3 M5 x8 screws. English 8. Insert the pipe arm into the round openings on the brackets until it is rested on the bottom bracket. 21

9. Install the camera to the top section. For installation details, refer to the Quick Installation Guide or page 15 in this document. 10. Swivel the pipe arm outwards to the opposite position. Use the M8 x70 bolts to secure the pipe arm to the brackets. You also need to tighten the M8 x25 bolts between the inner and outer brackets. IMPORTANT: When inserting the M8 bolts, you may damage the cables inside. Try twist the bolts a bit to get around cables if you feel resistance when inserting through the pipe. 22

A corner parapet installation should look like this when its installation is completed. English 23

This page is intentionally left blank. 24