MODEL: M2XU MODEL: M2XU [1][2] [3][4]

Similar documents
MODEL: W2TS. Mini-MW Series

MODEL: M6SXU MODEL: M6SXU [1][2] [3][4]

MODEL: M2XPA3. [2] EXCITATION 2: 4 V DC / 20 ma 3: 8 V DC / 20 ma 4: 12 V DC / 20 ma Configurator software is used to change the excitation value.

MODEL: M6SXT. POWER INPUT DC Power R: 24 V DC

MODEL: M2VF MODEL: M2VF [1][2] [3][4]

MODEL: M2EXT. Super-mini Signal Conditioners with Display Mini-M M2E Series

MODEL: M1EXT. with Display M1E Series

MODEL: M3LU. OUTPUT Field-selectable Current 0 20 ma DC Voltage V DC V DC

MODEL: M3LU2. OUTPUT Field-selectable Current 0 20 ma DC Voltage V DC V DC

MODEL: R30US4. Remote I/O R30 Series

MODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4]

MODEL: B3HU. Space-saving Two-wire Signal Conditioners B3-UNIT

MODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4]

MODEL: M2SES SEN TRONIC AG [3] OUTPUT

MODEL: M2DYS SEN TRONIC AG

MODEL: R1C-GH. Remote I/O R1X Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

MODEL: AS4V. Plug-in Signal Conditioners M-UNIT

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

MODEL: W2DYS SEN TRONIC AG. Mini-MW Series

MODEL: DA3. Plug-in Signal Conditioners M-UNIT

MODEL: KS. Plug-in Signal Conditioners K-UNIT

[3] MOUNTING DIRECTION

MODEL: JB2. Plug-in Signal Conditioners M-UNIT

MODEL: 27HU 27-UNIT MODEL: 27HU [1][2]

MODEL: RPPD. Plug-in Signal Conditioners M-UNIT. [2] INPUT 2 Must be the same code as the one chosen for Input 1.

MODEL: TC10EM. Temperature Controller TC10 Series

MODEL: MRP6. Final Control Elements

MODEL: MRP5. Final Control Elements. [2] TERMINAL BOX T: With

MODEL: RZMS-U9. PC Recorders RZMS Series

MODEL: 47LV. Digital Panel Meters 47 Series

JRQ2 ENCODER POSITION TRANSMITTER MODEL. Plug-in Signal Conditioners M-UNIT. (field-programmable; built-in excitation)

MODEL: JPR2. Plug-in Signal Conditioners M-UNIT

MODEL: R3-RS8A. Remote I/O R3 Series. RTD INPUT MODULE (high accuracy, 8 points, isolated) MODEL: R3-RS8A[1][2]

Assembly. Front view. Parametrization interface. Power Bus

MODEL: 47LPA. [2] ALARM OUTPUT 0: None 1: N.O. relay contact, 4 points 2: SPDT relay contact, 2 points. Digital Panel Meters 47 Series

MODEL: 20VS2-02. Hybrid IC Isolation Amplifiers 20 Series

MODEL: 27HU-B 27-UNIT. [3] LED INDICATOR 0: Without 1: With (SIL not available)

MODEL: 48NDVD. Bargraph Indicators 48N Series

General Specifications

BASIC FEATURES C %RH. Shimaden, Temperature and Humidity Control Specialists. CP3701: Thermocouple Temperature Converter

DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters

FC-33, DC SELECTABLE SIGNAL CONDITIONER

SHIMADEN DIGITAL INDICATORS

RZUS-U9 PC RECORDER MODEL. PC Recorders RZUS Series. (universal input, 12 points; isolated; bus-powered USB) MODEL & SUFFIX CODE SELECTION

MODEL: 48NAV. Bargraph Indicators 48N Series. [3] MOUNTING DIRECTION V: Vertical H: Horizontal

MODEL: 48NDV. Bargraph Indicators 48N Series

MODEL: R7C. Remote I/O R7 Series. CC-Link I/O MODULE. [2] POWER INPUT DC Power R: 24 V DC

General Specifications

Resistance Temperature Device Conversion Module

SHIMADEN DIGITAL INDICATORS

Isolated DIN Rail Mount Loop-Powered 2-Wire Signal Conditioners. DRLP Series

Multifunction Intelligent 4-wire Isolated Signal Conditioner

General Specifications

General Specifications

General Specifications

SINEAX V 624 Programmable Temperature Transmitter for RTD and TC inputs

JUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter)

SEM104 SERIES. SEM104P Pt100 Temperature Transmitter. SEM104TC Thermocouple Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.

SHIMADEN DIGITAL INDICATOR

General Specifications

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting

R24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY

PROGRAMMABLE FIELD TEMPERATURE TRANSMITTER

General Specifications

SEM1600T RTD/TC/SLIDE WIRE SIGNAL CONDITIONER

Temperature Transmitters - Head Mounted

Temperature transmitter itemp PCP DIN rail TMT 121

General Specifications

General Specifications

MODEL: M2CEC MODEL: M2CEC-[1][2][3]-[4][5]

JUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter)

Temperature head transmitter itemp PCP TMT 181

Process displays For standard signals, temperature, resistance measurement

C330 / C330X PC-Programmable Universal, 2-wire Transmitter

DRG-SC Series Signal Conditioners

DIGITAL PROGRAM CONTROLLER

High-precision process calibrator Model CED7000

SEM210 SEM210X UNIVERSAL TEMPERATURE TRANSMITTER

MODEL: R9CWTU. Remote I/O R9 Series. EXTENSION UNIT 1: With connection

D1072. SIL 2 Temperature Signal Converter, Duplicator, Adder/Subtractor DIN-Rail Models D1072S, D1072D. Front Panel and Features:

MODEL: SC110. Single Loop Controller Series. MULTI-FUNCTION PID CONTROLLER (color LCD with touch-panel, MV output backup) MODEL: SC110 [1]0 [2][3]

General Specifications

P5201 Universal Programmable Transmitters with Galvanic Isolation

SEM210 SERIES. Programmable In-head Universal Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.

General Specifications

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

Digital indicator for panel mounting With multi-function input Model DI25

General Specifications

TxBlock-USB Transmitter

Universal Intelligent 2-wire DIN Rail Transmitters

MODEL: R7G4HML3. Remote I/O R7G4H Series MECHATROLINK I/O MODULE (MECHATROLINK-III)

4002-ALM USER MANUAL 4002 ALM DUAL TRIP AMPLIFIER WITH RE-TRANSMITTED OUTPUT

General Specifications

Temperature Measurement

General Specifications

600T Series Transmitters. Specification Sheet. Model 653T Electronic temperature transmitter (PC programmable)

General Specifications

itemp HART DIN rail TMT112

MACX MCR-EX-T-UI-UP. Extract from the online catalog. Order No.:

Isolated Linearized 4-Wire RTD Input 5B35 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Transcription:

Super-mini Signal Conditioners Mini-M Series UNIVERSAL TRANSMITTER (PC programmable) Functions & Features Accepts direct inputs from various sensors and provides a standard process signal I/O types and calibration ranges are fully programmable via a PC Linearization up to 00 points can be programmed for DC and potentiometer inputs Isolation between input output power Typical Applications Signal conversion between control room and field instrumentation with isolation Ideal for use as a fast solution, multifunctional spare part Model 23 (.) 76 (2.) (.) mm (inch) MODEL: M2XU[][2][3][] ORDERING INFORMATION Code number: M2XU-[][2]-[3][] Specify a code from below for each [] through []. (e.g. M2XU-00-R/CE/Q) Specify the specification for option code /Q (e.g. /C0/S0) Non-specified orders will be shipped at default factory settings (M2XU-00: 20 ma input/ 20 ma output). However, the power suffix code must be specified. If you specify full code numbers without specific calibration ranges, default settings will be used. [] INPUT 0: User-calibrated (Factory default: 20 ma DC) If the unit is to be factory-calibrated to a specific input type, please select from the following: Current Z: Range 0 0 ma DC (Input resistance 00 Ω) Voltage S: Range - V DC (Input resistance MΩ min.) S2: Range -0 0 V DC (Input resistance MΩ min.) Thermocouple T: (PR) (Usable Range 0 to 760 C, 32 to 3200 F) T2: K (CA) (Usable range -270 to 370 C, - to 2 F) T3: E (CRC) (Usable range -270 to 000 C, - to 32 F) T: J (IC) (Usable range -20 to 00 C, -36 to 22 F) T: T (CC) (Usable range -270 to 00 C, - to 72 F) T6: B (RH) (Usable range 0 to 20 C, 32 to 330 F) T7: R (Usable range -0 to 760 C, - to 3200 F) T: S (Usable range -0 to 760 C, - to 3200 F) T: C (WRe -26) (Usable range 0 to 23 C, 32 to F) TN: N (Usable range -270 to 300 C, - to 2372 F) TU: U (Usable range -200 to 00 C, -32 to 72 F) TL: L (Usable range -200 to 00 C, -32 to 62 F) TP: P (Platinel II) (Usable range 0 to 3 C, 32 to 23 F) T0: Specify (Please provide an emf table.) RTD (2- or 3-wire) R: JPt 00 (JIS') (Usable range: -200 to 00 C, -32 to 32 F) R3: Pt 00 (JIS') (Usable range: -200 to 0 C, -32 to 62 F) R: Pt 00 (JIS'7, IEC) (Usable range: -200 to 0 C, -32 to 62 F) R: Pt 0 Ω (JIS') (Usable range: -200 to 6 C, -32 to 00 F) R6: Ni 0. Ω (Usable range: -0 to 200 C, - to 32 F) R7: Pt 000 (Usable range: -200 to 200 C, -32 to 32 F) R: Ni 00 (Usable range: -0 to 200 C, - to 32 F) R: Cu 0 @2 C (Usable range: -0 to 200 C, - to 32 F) R0: Specify (Please provide a resistance table.) Potentiometer M: Total resistance 00 Ω 0 kω Note: Consult M-System for 2-wire RTD [2] OUTPUT 0: User-calibrated (Factory default: 20 ma DC) If the unit is to be factory-calibrated to a specific output type, please select from the following: Current Z: Range 0 20 ma DC Voltage V: Range -2. 2. V DC V2: Range -0 0 V DC M2XU SPECIFICATIONS ES-00 Rev.6 Page /6

[3] POWER INPUT AC Power M2: 00 20 V AC (Operational voltage range 26 V, 7 66 Hz) (0 26 V for UL) DC Power R: 2 V DC (Operational voltage range 2 V ±0 %, ripple 0 %p-p max.) P: 0 V DC (Operational voltage range 0 V, ripple 0 %p-p max.) (0 V ±0 % for UL) [] OPTIONS (multiple selections) Standards & Approvals (must be specified) /N: Without CE or UL /CE: CE marking /UL: UL approval, CE marking Other Options blank: none /Q: Option other than the above (specify the specification) (UL not available) SPECIFICATIONS OF OPTION: Q (multiple selections) COATING (For the detail, refer to M-System's web site.) /C0: Silicone coating /C02: Polyurethane coating /C03: Rubber coating TERMINAL SCREW MATERIAL /S0: Stainless steel RELATED PRODUCTS PC configurator software (model: JXCON) Downloadable at M-System s web site. A dedicated cable is required to connect the module to the PC. Please refer to the internet software download site or the users manual for the PC configurator for applicable cable types. GENERAL SPECIFICATIONS Construction: Plug-in Connection: M3 screw terminals (torque 0. N m) Screw terminal: Chromated steel (standard) or stainless steel Housing material: Flame-resistant resin (black) Isolation: Input to output to power Overrange output: Approx. - to % (Negative current output is not provided.) Manual zero adjustments: - to % (factory setting: 0 %) Manual span adjustments: to 0 % (factory setting: 00 %) Programming: PC programmable features include: T/C and RTD type and temp. range Input and output ranges Zero and span adjustments Simulated output User's linearization table (max. 00 points, specified within - % for both input and output) User s TC/RTD table Burnout (T/C, RTD and Pot.): Upscale standard; downscale or no burnout options are PC programmable Linearization (T/C, RTD input): Standard tables stored in memory Cold junction compensation (T/C): CJC sensor (included) to be attached to the input terminals Status indicator LED: Blinking patterns indicate different operating status of the transmitter. Configurator connection: 2. dia. miniature jack; RS-232-C level INPUT SPECIFICATIONS DC Current: Shunt resistor attached to the input terminals (0. W) Operational range: 0 70 ma DC with 00 Ω, 0. W Input range: 0 0 ma DC Minimum span: 2 ma input range provided that the minimum span is maintained. If not specified, the input range is 20 ma DC. DC Voltage Operational range: -.. V DC Input range: -0 0 V DC Minimum span: 0 mv for S; 00 mv for S2 input range provided that the minimum span is maintained. If not specified, the input range is shown below. S: 0 00 mv DC S2: V DC Thermocouple For T/C types K, E, T, B, R, S or N, the accuracy in the temperature ranges near the lower limit may be out of the described value. Consult M-System for more detail. Input resistance: MΩ min. Burnout sensing: na ±0 % input range provided that the minimum span is maintained. If not specified, the input range is shown below. T PR: 0 600 C T2 K: 0 000 C T3 E: 0 00 C T J: 0 00 C T T: 0 300 C M2XU SPECIFICATIONS ES-00 Rev.6 Page 2/6

T6 B: 0 00 C T7 R: 0 600 C T S: 0 600 C T C: 0 2000 C TN N: 0 000 C TU U: 0 300 C TL L: 0 00 C TP P: 0 00 C RTD Maximum leadwire resistance: 200 Ω per wire (3 -wire) Sensing current:.0 ma If not specified, the input range is shown below. R: JPt 00 0 00 C R3: Pt 00 0 00 C R: Pt 00 0 00 C R: Pt 0 Ω 0 200 C R6: Ni 0. Ω 0 00 C R7: Pt 000 0 00 C R: Ni 00 0 00 C R: Cu 0 0 00 C Potentiometer: 00 Ω 0 kω Minimum span: (Range) 0 00 Ω : 2. Ω 0 300 Ω : 3.0 Ω 0 000 Ω : 0 Ω 0 0 kω : 0 Ω Excitation: 0. V DC at 000 Ω If not specified, the input range is 0 000 Ω. OUTPUT SPECIFICATIONS DC Current Operational range: 0 2 ma DC Output range: 0 20 ma DC Minimum span: ma output range provided that the minimum span is maintained. Load resistance: Output drive V max. (e.g. 20 ma: 70 Ω [ V 20 ma]) If not specified, the output range is 20 ma DC. DC Voltage Code V (narrow spans) Operational range: -3 3 V DC Output range: -2. 2. V DC Minimum span: 20 mv Code V2 (wide spans) Operational range: -.. V DC Output range: -0 0 V DC Minimum span: V output range provided that the minimum span is maintained. Load resistance: Output drive ma max. (e.g. V: 000 Ω [ V ma]) If not specified, the output range is shown below. V: 0 V DC V2: V DC INSTALLATION Power Consumption AC: Approx. 6 VA DC: Approx. 3 W Operating temperature: -30 to 60 C (-22 to 0 F) Operating humidity: 30 to 0 %RH (non-condensing) Mounting: Surface or DIN rail Weight: 0 g (0.26 lb) PERFORMANCE Accuracy: Input accuracy output accuracy Input accuracy (% of input range) Inversely proportional to span. (DC) - V : ±0.02-0 0 V : ±0.02 0 0 ma : ±0.02 Except the input resistor error. (T/C) (PR) : ±0.0 K (CA) : ±0.02 E (CRC) : ±0.02 J (IC) : ±0.0 T (CC) : ±0.06 B (RH) : ±0. R : ±0.0 S : ±0.0 C (WRe - 26) : ±0.0 N : ±0.0 U : ±0.0 L : ±0.0 P (Platinel II) : ±0.0 (RTD) JPt 00 (JIS ) : ±0.0 Pt 00 (JIS ) : ±0.03 Pt 00 (JIS 7, IEC) : ±0.03 Pt 0 Ω (JIS ) : ±0.0 Ni 0. Ω : ±0.0 Pt 000 : ±0.0 Ni 00 : ±0. Cu 0 : ±0.6 (Pot.) 0 00 Ω : ±0.0 0 300 Ω : ±0.0 0 000 Ω : ±0.0 0 0 kω : ±0.0 Output accuracy: ±0.02 % of output range Inversely proportional to span. Cold junction compensation error: M2XU SPECIFICATIONS ES-00 Rev.6 Page 3/6

±0. C or ±0.7 F (at 20 C ±0 C or 6 F ± F) Temp. coefficient (at - to C [23 to 3 F] of I/O range) Input: ±0.06 %/ C (±0.00 %/ F) with current ±0.00 %/ C (±0.002 %/ F) with voltage ±0.00 %/ C (±0.002 %/ F) with T/C ±0.00 %/ C (±0.002 %/ F) with RTD ±0.00 %/ C (±0.002 %/ F) with Pot. Output: ±0.03 %/ C (±0.007 %/ F) Response time: 0. sec.(0 0 %) with current 0. sec.(0 0 %) with voltage. sec.(0 0 %) with T/C 0. sec.(0 0 %) with RTD 0. sec. (0 0 %) with Pot. Burnout response: 0 sec. Line voltage effect: ±0. % over voltage range Insulation resistance: 00 MΩ with 00 V DC Dielectric strength: 2000 V AC @ minute (input to output to power to ground) CALCULATION EXAMPLES OF OVERALL ACCURACY [Example] Input Type -0 0 V, Input Range V, Output Type 0 20 ma, Output Range 0 0 ma Max. Input Range (20 V) Span ( V) 0.02 % = 0. % Max. Output Range (20 ma) Span (0 ma) 0.02 % = 0.0 % Overall accuracy = 0. 0.0 = ±0. % STANDARDS & APPROVALS EU conformity: EMC Directive EMI EN 6000-6- EMS EN 6000-6-2 Low Voltage Directive EN 600- Installation Category II Pollution Degree 2 Input or output to power: Reinforced insulation (300 V) Input to output: Basic insulation (300 V) RoHS Directive EN 0 Approval: UL/C-UL nonincendive Class I, Division 2, Groups A, B, C, and D (ANSI/ISA-..0, CAN/CSA-C22.2 No.23) UL/C-UL general safety requirements (UL 600-, CAN/CSA-C22.2 No.600-) M2XU SPECIFICATIONS ES-00 Rev.6 Page /6

EXTERNAL VIEW FRONT VIEW (with cover open) RIGHT SIDE VIEW Configurator Jack Status Indicator LED Zero/Span Selector Top: SPAN Middle: OFF Bottom: ZERO UP/DOWN Switches Input Range Selector Position H: code S2, Z Position L : other The front cover cannot be opened to 0 deg. when flush with neighboring units. Refer to the instruction manual for detailed procedures. DIMENSIONS unit: mm (inch) 6 (.23) 70. (2.7) DIN RAIL 3mm wide 2.2x (.7x.20) MTG HOLE 6 (.2) deep (2.32) 72 (2.3) M3 SCREW 3 2. (.) 7.3 (.2) 6.7 (3.) (.) 6.7 (.) [ (.6)] 23 (.) (.6) When mounting, no extra space is needed between units. TERMINAL ASSIGNMENTS unit: mm (inch) Use the input resistor (model: REM2) for a DC current input, and the CJC sensor (model: CJM) for a thermocouple input, both included in the package. INPUT RESISTOR (model: REM2) CJC SENSOR (model: CJM) (.) (.7) black red 3 3 M2XU SPECIFICATIONS ES-00 Rev.6 Page /6

SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM DC R * T/C ext. wire CJC SENSOR (model: CJM) black red RTD A B B POT. max. min. 3 2 INPUT RANGE SELECTOR Low Drift Amplifier & Burnout STATUS ZERO/SPAN SELECTOR Digital Computation UP/DOWN SWITCHES Isolation Output Driver 3 U() V() OUTPUT POWER CONFIGURATOR JACK Base Socket *Input shunt resistor attached for current input. Specifications are subject to change without notice. M2XU SPECIFICATIONS ES-00 Rev.6 Page 6/6