Multi-layer Insulation Blanket for Roofs, Walls & Floors The Highest Performing Certificated MultiFoil on the Market
|
|
- Augustine Atkinson
- 5 years ago
- Views:
Transcription
1 Multilayer Insulation Blanket for Roofs, Walls & Floors e The Highest Performing Certificated MultiFoil on the Market MultifoilInsulation.com UK and European Distributors Specialising in Multifoil Insulation Solutions
2 Insulation for use in Roofs General NHBC Acceptance Meets r equirements of L1A and L1B 2010 addition In accor dance with BR443 Thermally tested in accor dance with EN16012 High thermal r esistance of 2.50m²K/W Effective solar overheating barrier Effective in summer and winter Fast and simple installation Tear Resistant For pitched roofs between 20 O and 70 O insulation thermally tested in accordance with EN16012 achieving a high thermal resistance of 2.50m²K/W for accompanied by a 25mm air cavity either side of the material. Installation of for pitched roof applications and additional insulation products should be in accordance with the building practice. must be installed with a 50mm overlap with all joints taped with ThermaSeal 75mm foil tape. can be cut with a craft knife or a sharp pair of scissors. vals. Minimum 14mm stainless steel or galvanised staples are recommended. is most effective with a minimum 25mm air gap on either side. Battens can be used to create this gap. No protective clothing/handling required. How does Work? Due to the special composition of multilayers of insula tion, effectively deals with all forms of energy transfer (i.e. conduction, convection and radiation). radiation. This means that not only is effecand cold out, but also in summer, is a very effective barrier to solar overheating which reduces the accumulation of heat within the building.
3 Under Rafter Pitch Roof Installation of for under rafter applications and additional insulation products should be in accordance with UValue Combined Method (W/m 2 K) 0.18 (W/mK) (m 2 K/W) good building practice. Outside Surface is applied directly from the roll either vertically or horizontally depending on the rafter height, pulled tight and stapled onto the rafters at minimum 300mm centres should be overlapped at each joint by approx. 50mm and stapled onto the rafters, the joints should be sealed using ThermaSeal Foil Tape. Additionally, at the eaves is cut around the rafters and sealed to the Cavity wall insulation or wall plate Fix 25mm by 38mm battens at right angel to rafters. Battens battens in the usual manner. Total When installed below rafters will perform as a vapour barrier. Outside Surface See our HowTo Videos please vist UValue table All calculations are based on 50mm rafters and include the e Description (rafters at 400mm centres) UValue and 75mm (0.022 W/mk) 0.18 W/m 2 k and 130mm Glasswool (0.040 W/mK) 0.18 W/m 2 k and 110mm (0.022 W/mk) 0.15 W/m 2 k and 140mm (0.022 W/mK) 0.13 W/m 2 k Description (rafters at 600mm centres) UValue and 70mm (0.022 W/mk) 0.18 W/m 2 k and 120mm Glasswool (0.040 W/mK) 0.18 W/m 2 k and 95mm (0.022 W/mk) 0.15 W/m 2 k and 125mm (0.022 W/mK) 0.13 W/m 2 k 5
4 Over Rafter Pitch Roof Installation of for over rafter applications and additional insulation products should be in accordance with UValue Combined Method (W/m 2 K) 0.18 (W/mK) (m 2 K/W) good building practice. Outside Surface is applied directly from the roll either vertically or horizontally depending on the rafter height, pulled tight and stapled onto the rafters at minimum 300mm centres should be overlapped at each joint by approx. 50mm and stapled onto the rafters, the joints should be sealed using ThermaSeal Foil Tape. Additionally, at the eaves is cut around the rafters and sealed to the Cavity wall insulation or wall plate Vapour Control perimeter of windows Total battens and tiles. A vapour control layer should be condensation. Outside Surface Vapour Control Calculated to include timber bridging UValue table All calculations are based on 50mm rafters and include the effect of cold bridging. For individual calculation please contact the technical team on Description (rafters at 400mm centres) UValue and 80mm (0.022 W/mk) 0.18 W/m 2 k and 135mm Glasswool (0.040 W/mK) 0.18 W/m 2 k and 115mm (0.022 W/mk) 0.15 W/m 2 k and 145mm (0.022 W/mk) 0.13 W/m 2 k Description (rafters at 600mm centres) UValue and 70mm (0.022 W/mk) 0.18 W/m 2 k and 125mm Glasswool (0.040 W/mK) 0.18 W/m 2 k and 100mm (0.022 W/mk) 0.15 W/m 2 k and 130mm (0.022 W/mk) 0.13 W/m 2 k
5 Two Layer Pitch Roof Installation of for under rafter applications and additional insulation pr oducts should be in accordance with UValue Combined Method (W/m 2 K) 0.18 (W/mK) (m 2 K/W) good building practice. Outside Surface For recessed installation please see page instructions. When installing two layers of a 38mm air space should be maintained between layers at all times Phenolic See our HowTo Videos at Total Roof Covering Slate/Tiling Batten Outside Surface Rafters Batten or Staple Insulated Perpendicular batten Insulated Calculated to include timber bridging UValue table All calculations are based on 50mm rafters and include the effect of cold bridging. For individual calculation please contact the technical team on Description (rafters at 400mm centres) UValue (2 Layers) with 40mm insulated (XPS) (1.070 m 2 K/W) 0.18 W/m 2 k (2 Layers) and 50mm (0.022 W/mK) 0.15 W/m 2 k (2 Layers) and 57.5mm Insulated () (2.2 m 2 K/W) 0.15 W/m 2 k (2 Layers) and 80mm (0.022 W/mK) 0.13 W/m 2 k Description (rafters at 600mm centres) UV alue (2 Layers) with 40mm insulated (XPS) (1.070 m 2 K/W) 0.18 W/m 2 k (2 Layers) and 45mm (0.022 W/mK) 0.15 W/m 2 k (2 Layers) and 57.5mm Insulated () (2.2 m 2 K/W) 0.15 W/m 2 k (2 Layers) and 70mm (0.022 W/mK) 0.13 W/m 2 k
6 Three Layer MultiFoil System Roof Covering Slate/Tiling Batten Air Space/Batten BreatherQuilt Fitting Instructions: BreatherQuilt is stapled directly to the aluminium foil facing downwards. Start at the edge of the roof and work horizontally. Tape a line of ThermaSeal Double Sided tape along the top edge of the material. Install the next layer of BreatherQuilt using a 100mm overlap. Once the roof is fully covered are 75mm or less you will need a vertical batten first. install both layers of. Recessing the Once stapled, fully tape and seal using True Aluminium ThermaSeal Foil Joining Tape. Once the first layer has been installed, staple a second layer of directly through the first layer using 14mm staples. Pull this Fully tape and seal the second layer to ensure the product works as a high performing Vapour Control layer. You can now install 25mm battens before plasterboard finish. No Requirement for Rigid Boards or Mineral Wool! Can be installed in little as Airspace/Recess Air Space/Batten UValue Combined Method (W/m2K) 0.18 (W/m2K) (m2k/w) Outside Surface BreatherQuilt Total Outside Surface BreatherQuilt Insulated Free Next Working Day Delivery on orders over 100+Vat Calculated to include timber bridging To Order BreatherQuilt or for anymore Information Visit MultiFoilInsulation.com Or Call our dedicated team on
7 Under Joist Flat Roof UValue Combined Method (W/m 2 K) 0.18 and additional insulation products should be in accordance (W/mK) (m 2 K/W) current good building practice. should be overlapped at each joint by approx. 50mm and stapled onto the joists, the joints should be sealed using ThermaSeal Foil Foil Tape when is cut to fit around openings or connections, gaps must be minimized and any exposed cut edges should be sealed with YBS Foil Tape to prevent condensation. should be cut equal to the width of the roof section plus 100mm. Installation should start from the external wall with being unrolled perpendicular to the joists, after which it is stapled, nailed or screwed using saddle clips. Cavity (ventilated) Total should be held in place using timber battens or by other means as shown, in such a way that there is a nominal 25mm air cavity above the product (if applicable) and a nominal 25mm air cavity below. To minimize the effect of thermal bridging cross battening is advised. Cavity (ventilated) When installed below joists will perform as a vapour barrier. UValue table All calculations are based on 50mm joists and include the effect of cold bridging. For individual calculation please contact the technical team on Description (rafters at 400mm centres) UValue and 160mm Mineral Wool (0.040 W/mk) 0.18 W/m 2 k and 140mm Mineral Wool (0.033 W/mk) 0.18 W/m 2 k and 180mm Mineral Wool (0.033 W/mk) 0.15 W/m 2 k and 100mm (0.022 W/mk) 0.18 W/m 2 k and 135mm (0.022 W/mk) 0.15 W/m 2 k and 165mm (0.022 W/mk) 0.13 W/m 2 k Description (rafters at 600mm centres) UValue and 150mm Mineral Wool (0.040 W/mk) 0.18 W/m 2 k and 125mm Mineral Wool (0.033 W/mk) 0.18 W/m 2 k and 170mm Mineral Wool (0.033 W/mk) 0.15 W/m 2 k and 90mm (0.022 W/mk) 0.18 W/m 2 k and 120mm (0.022 W/mk) 0.15 W/m 2 k and 145mm (0.022 W/mk) 0.13 W/m 2 k
8 Under Joist Flat Roof UValue Combined Method (W/m 2 K) 0.18 and additional insulation products should be in accordance (W/mK) (m 2 K/W) current good building practice. should be overlapped at each joint by approx. 50mm and stapled onto the joists, the joints should be sealed using ThermaSeal Foil Tape when is cut to fit around openings or connections, gaps must be minimized and any exposed cut edges should be sealed with YBS Foil Tape to prevent condensation. should be cut equal to the width of the roof section plus 100mm. Installation should start from the external wall with being unrolled perpendicular to the rafters, after which it is fixed using staples, nails or saddle clips. should be held in place using timber battens or by other means as shown, in such a way that there is a nominal 25mm air cavity above the product (if applicable) and a nominal 25mm air cavity below. To minimize the effect of thermal bridging cross battening is advised. Cavity (ventilated) Cavity (nonventilated) Total Cavity ventilated When installed below joists will perform as a vapour barrier. NonVentilated Cavity UValue table All calculations are based on 50mm joists and include the effect of cold bridging. For individual calculation please contact the technical team on Description (rafters at 400mm centres) UValue and 140mm Mineral Wool (0.040 W/mk) 0.18 W/m 2 k and 120mm Mineral Wool (0.033 W/mk) 0.18 W/m 2 k and 170mm Mineral Wool (0.033 W/mk) 0.15 W/m 2 k and 90mm (0.022 W/mk) 0.18 W/m 2 k and 120mm (0.022 W/mk) 0.15 W/m 2 k and 150mm (0.022 W/mk) 0.13 W/m 2 k Description (rafters at 600mm centres) UValue and 130mm Mineral Wool (0.040 W/mk) 0.18 W/m 2 k and 110mm Mineral Wool (0.033 W/mk) 0.18 W/m 2 k and 150mm Mineral Wool (0.033 W/mk) 0.15 W/m 2 k and 80mm (0.022 W/mk) 0.18 W/m 2 k and 110mm (0.022 W/mk) 0.15 W/m 2 k and 135mm (0.022 W/mk) 0.13 W/m 2 k
9 Over Joist Flat Roof UValue Combined Method (W/m 2 K) 0.18 and additional insulation products should be in accordance (W/mK) (m 2 K/W) current good building practice should be overlapped at each joint by approx. 50mm and stapled onto the joists, the joints should be sealed using ThermaSeal Foil Tape when is cut to fit around openings or connections, gaps must be minimized and any exposed cut edges should be sealed with YBS Foil Tape to prevent condensation. should be cut equal to the width if the roof section plus 100mm. Installation should start from the external wall with being unrolled perpendicular to the rafters, NonVentilated Cavity NonVentilated Cavity Total clips. should be held in place using timber battens or by other means as shown, in such a way that there is a nominal 25mm air cavity above the product (if applicable) and a nominal 25mm air cavity below. To minimize the effect of thermal bridging cross battening is advised. NonVentilated Cavity Additional insulation should be installed above the. When installed below rafters will perform as a vapour barrier. NonVentilated Cavity UValue table All calculations are based on 50mm joists and include the effect of cold bridging. For individual calculation please contact the technical team on Description (rafters at 400mm centres) UValue and 65mm (0.022 W/mk) 0.18 W/m 2 k and 90mm (0.022 W/mk) 0.15 W/m 2 k and 105mm (0.022 W/mk) 0.13 W/m 2 k and 85mm XPS (0.029 W/mk) 0.18 W/m 2 k and 120mm XPS (0.029 W/mk) 0.15 W/m 2 k and 140mm XPS (0.029 W/mk) 0.13 W/m 2 k Description (rafters at 600mm centres) UValue and 65mm (0.022 W/mk) 0.18 W/m 2 k and 90mm (0.022 W/mk) 0.15 W/m 2 k and 105mm (0.022 W/mk) 0.15 W/m 2 k and 85mm XPS (0.029 W/mk) 0.18 W/m 2 k and 120mm XPS (0.029 W/mk) 0.15 W/m 2 k and 135mm XPS (0.029 W/mk) 0.13 W/m 2 k
10 Two Layer Flat Roof UValue Combined Method (W/m 2 K) 0.18 roof applications with additional insulation should be (W/mK) (m 2 K/W) instructions and current good building practice should be overlapped at each joint by approx. 50mm and stapled onto the rafters, the joints should be using ThermaSeal Foil Tape when is cut to fit around openings or connections, gaps must be minimized and any exposed cut edges should be sealed with YBS Foil Tape to prevent condensation. should be cut equal to the width of the roof section plus 100mm. Installation should start from the external wall with being unrolled perpendicular to the joists after which it is fixed using staples, nails or saddle clips. NonVentilated Cavity NonVentilated Cavity Total should be held in place using timber battens or by other means as shown, in such a way that there is a nominal 25mm air cavity above the product (if applicable) and a nominal 25mm air cavity below. To minimize the effect of thermal bridging cross battening is advised. NonVentilated Cavity When installed below joists will perform as a vapour barrier. NonVentilated Cavity UValue table All calculations are based on 50mm joists and include the effect of cold bridging. For individual calculation please contact the technical team on Description (rafters at 400mm centres) UValue and 50mm Mineral Wool (0.040 W/mk) 0.18 W/m 2 k and 100mm Mineral Wool (0.040 W/mk) 0.15 W/m 2 k and 40mm Mineral Wool (0.033 W/mk) 0.18 W/m 2 k and 30mm (0.022 W/mk) 0.18 W/m 2 k and 65mm (0.022 W/mk) 0.15 W/m 2 k and 75mm (0.022 W/mk) 0.13 W/m 2 k Description (rafters at 600mm centres) UValue and 50mm Mineral Wool (0.040 W/mk) 0.18 W/m 2 k and 90mm Mineral Wool (0.040 W/mk) 0.15 W/m 2 k and 40mm Mineral Wool (0.033 W/mk) 0.18 W/m 2 k and 25mm (0.022 W/mk) 0.18 W/m 2 k and 55mm (0.022 W/mk) 0.15 W/m 2 k and 65mm (0.022 W/mk) 0.13 W/m 2 k
11 Recessed Detail Over Rafter Application Under Rafter Application Where roof height is critical can be recessed between the rafters. 1.. Ensure that there is an airspace above the at all times staples or with battens. 2. staples or with battens. 3. instruction instruction is then wrapped around the rafter and the procedure starts again. 4. is then wrapped around the rafter and the procedure starts again. using ThermaSeal Foil Tape. using ThermaSeal Foil tape. the rafters below the. Over Rafter Under Rafter Roof Covering Slate/Tiling Batten Batten or Staple Roof Covering Slate/Tiling Batten Batten or Staple & Finish & Finish Insulation joints ThermSeal Foil Taped Insulation joints ThermaSeal Foil Taped To see an easy way to recess, please see our HowTo Video (Superquilt Double Layer) at Call us on for more Technical Information or to Order
12 Purlin Details Between Purlins Application Around Purlins Application the underside of the the rafters. At the purlins the is turned up and stapled in place. the underside of the the rafters. At the purlins the is cut and pushed behind the purlins then taped to the next piece at the opposite side of the purlin. rafters crushing the tightly against the purlins. the rafters. Between Purlins Around Purlins Roo Roo Slate/Tiling Batten Slate/Tiling Batten Between Rafters Rafters Between Rafters Rafters Insulation joints ThermaSeal Foil Taped Insulation joints ThermaSeal Foil Taped & Finish & Finish Perpendicular 25mm battens Perpendicular 25mm battens Purlin Purlin See our Free to use Online UValue Calculator at MultifoilInsulation.com
13 Detailing Vents / Light Pipes Collar/Flashing Tiles/Slate Tiles/Slate Batten Counter Batten turned up at the vent/wall/rooflight and sealed with ThermaSeal Foil Tape. Battens are placed on the rafters above the Super battens and then tiles. Rafter Flashing Flashing Tiles/Slate Tiles/Slate Batten Counter Batten Rafter Rooflight Flashing Tiles/Slate Tiles/Slate Batten Counter Batten Rafter Bespoke UValue Calculations avaliable from MultifoilInsulation.com
14 Detailing Over Rafter Fixing Details Eaves is stapled to the rafters. At the eaves the is cut and taken down between the rafters to the cavity wall insulation or the wall plate. The needs to be sealed with staples and taped to the rafters and the cavity wall insulation or wall plate to create an airtight envelope. Under Rafter Fixing Details Tiles Battens Counter Battens Foil Taped Joints Rafter Timber Wallplate is stapled to the underside of the rafters. At the eaves the is cut and taken down between the joists to the cavity wall insulation or the wall plate. The staples and taped to the joists and cavity wall insulation or wall plate so that an airtight envelope is created. ThermaSeal Foil taped joins Valleys Tiles Tile Battens Felt Membrane Counter Battens should be overlapped at each joint by approx. 50mm and stapled onto the battens, the joints should be sealed using Genuine ThermaSeal 75mm Foil Tape. Lead Gutter Mortar Pointing Rafters Vapour control layer When all joints are sealed using ThermaSeal foil tape also works as a vapour control layer. Downlighters Perpendicular Battens Fitting Equipment At MultiFoilInsulation.com we supply a range of fitting equipment such as Genuine ThermaSeal Foil Tape, Double Sided Tape, Pipe and Saddle Clips, Staple Gun Kits, Knifes and Scissors. Ideal for all Multifoil installation projects. We Recommend using Fire Hoods when installing downlighters A circular hole is cut in the to create a minimum 25mm clearance from the downlighter. The cut edge must be completely sealed using ThermaSeal Foil Tape.
15 MultiFoilInsulation.com have a range of HowTo Videos. We also have Data Sheets for Walls and Floors. For more Technical Information Please call us on Product Description 19 Components Technical Properties 40mm appr ox. Weight 800g/m 2 Mechanical Properties Value Refer ence Standard Thermal performance Cor e 1.52m 2 K/W BS EN Roof 2.50m 2 K/W BS EN 6946 Wall 3.00m 2 K/W BS EN 6946 Floor 4.45m 2 K/W BS EN 6946 Flammability Class E BS EN Water vapour resistance 1569MNs/g BS EN BS EN Tensile strength 142KP A BS EN 1608 Packaging 15m 2 7.5m 2 Width 1.5m 1.5m Length 10m 5m Weight 12.5Kg 6.25Kg MultifoilInsulation.com UK and European Distributors Specialising in Multifoil Insulation Solutions Tel: sales@multifoilinsulation.com Try our Free and Easy To Use Online UValue Calculator!
Multi-layer Insulation Blanket for Roofs
Multilayer Insulation Blanket for Roofs Thermal Insulation in a 40mm thin, flexible, multilayer membrane Meets requirements of L1A, L1B 2010 In accordance with BR443 NHBC Acceptance Pitched roof insulation
More informationTo Order Superquilt direct at Lowest prices in the UK or Europe UK Customers Call From outside the UK Call
Data Sheet for Fitting Superquilt Under or over Rafters to Roofs To Order Superquilt direct at Lowest prices in the UK or Europe UK Customers Call 0844 9919949 From outside the UK Call 0044 1143230474
More informationMulti-layer Insulation Blanket for
Data Sheet for Fitting Superquilt Under or over Rafters to Roofs To Order Superquilt direct at Lowest prices in the UK or Europe UK Customers Call 0844 9919949 From outside the UK Call 0044 1143230474
More informationMulti-layer Insulation Blanket for
Pitched roof insulation Fully certificated Thermally tested in accordance with EN12667 High thermal resistance of 2.71m²K/W Class 1 Surface spread of flame Ideal for New build & Refurbishment Effective
More informationMulti-layer Insulation Blanket for use in Roofs
Multi-layer Insulation Blanket for use in Roofs Massive Thermal Insulation in a Thin, Flexible, Multi-layer Membrane HIGHEST PERFORMING MULTI-FOIL ON FULLY INDEPENDENTLY THE MARKET TESTED KEEPS YOUR FULLY
More informationSuperFOIL Insulation. Solutions Guide. Pitched Roof - Under Rafter
SuperFOIL Insulation Solutions Guide Pitched Roof - Under Rafter SF19+ Pitched Roof Under Rafter Solutions CONSTRUCTION THICKNESS R -VALUE EXTERNAL SURFACE - 0.040 TILES / SLATES 10mm - BATTEN CAVITY 25mm
More informationAugust 2008: Issue 1. Non - Residential New Build Pitched Roofs - Rafter Level
Non - Residential New Build 4.2.3 Pitched Roofs - Rafter Level August 2008: Issue 1 Non-residential new build 4.0 Non-residential New Build Pitched Roof - Rafter Level Contents Introduction find online
More informationPitched roofs rafter level
Pitched Roofs - Rafter Level Pitched roofs rafter level Insulation at rafter level design Rafter level insulation Insulation between the rafters can be designed in two ways: Breathing roof with Low Resistance
More informationJune Residential Refurbishment Pitched roofs - rafter level
June 2010 Residential Refurbishment 3.2.2 Pitched roofs - rafter level Residential refurbishment 3.0 Residential Refurbishment Pitched Roof - Rafter Level Contents Introduction find online page Solution
More informationJune Non - Residential Refurbishment Pitched roofs - rafter level
June 2010 Non - Residential Refurbishment 5.2.3 Pitched roofs - rafter level Non-residential refurbishment 5.0 Non-residential Refurbishment Pitched Roof - Rafter Level Contents Introduction find online
More informationTRISO-SUPER 10 Installation Guidelines
V 2007 ACTIS THIN MULTIFOIL INSULATION Installation Guidelines ROOFS ATTICS 2 Contents Technical characteristics 2 Essential rules of installation 3 Over rafter installation 4 Under rafter installation
More informationInstallation. Openings: Valley: Installation on timber roofs (new buildings) 1. Fit a support (noggins) around the opening.
Installation Openings: 1. Fit a support (noggins) around the opening. 2. Apply Isola Sealant to the support and then fit Pro Super. 3. Install an Isola Opening Fitting for round or square openings. (Remember
More informationmanthorpe Roll-Out Dry Fix Ridge System building products Fixing Instructions MBP 8265e
manthorpe building products Roll-Out Dry Fix Ridge System Fixing Instructions MBP 8265e Ridge Details Fig A. Assembly View of Dry Ridge Detail s/s screw clamping plate rubber washer foam spacer ridge tile
More informationCertificate No: EW560
Certificate No: EW560 Thermic Technology Ltd - PhotonAir Description of Product This is an assessment of PhotonAir a breathable lightweight thin flexible insulation that incorporates breathable roofing
More informationNEW equinox INSTALLATION GUIDE Issue
NEW equinox INSTALLATION GUIDE Issue 1 CONTENTS If in doubt at any stage 1. Preparing the ring beam 2 2. Installing the framework 3 3. Insulation and waterproofing 7 4. Tile application: Steel tiles 9
More informationGV Standard Pitchglaze
GV Standard Pitchglaze Installation Manual Technical experts in the design, manufacture and supply of precision engineered, architectural rooflights for residential and commercial buildings. 201-INST-101
More informationSUPER-UNDERLAY SHEET
SUPER-UNDERLAY SHEET SBS modified bitumen underlay sheet Producer: KATEPAL OY P.O.Box 33 FI-37501 LEMPÄÄLÄ FINLAND Telephone +358 3 375 9111 Telefax +358 3 375 0974 E-mail: katepal@katepal.fi www.katepal.fi
More informationRoll-Fix Kit The complete dry hip kit RFIG
H I P Roll-Fix Kit The complete dry hip kit RFIG.045-0906-1 Roll-Fix is a quick and simple dry-fix roofing kit for hips. l Quick and easy to install no special tools required l Universal application fits
More informationNEW equinox INSTALLATION GUIDE Issue
NEW equinox INSTALLATION GUIDE Issue 2 CONTENTS 1. Preparing the ring beam 2 2. Installing the framework 3 3. How to install structural support posts 7 4. Insulation and waterproofing 8 5. Tile application:
More informationInstallation Guide. Please read before installing SIPs Kit. 1 Method Statement for the erection of a SIPS Industries Kit Materials...
30a Renewable Chase Bibra Lake WA 6163 Tel: (08) 9494 2211 Fax: (08) 9494 2202 Email: info@sipsindustries.com.au Web: www.sipsindustries.com.au Installation Guide Please read before installing SIPs Kit.
More informationREDLAND DRY VALLEY. Installation Instructions for Redland Dry Valley. Version: 6. Date: May Redland Technical Solutions
REDLAND DRY VALLEY Installation Instructions for Redland Dry Valley Version: 6 Date: May 2013 Author: Department: Redland Technical Solutions Redland Technical Solutions 1 Introduction 1.1 TECHNICAL DATA
More informationContents. Stage 1. Preparation of the aperture 9. Interior finishing 25
Installation Manual Pitchglaze Roof Window Contents Contents and introduction 2 Delivery 3 Pre Installation 4 Installation 8 Stage 1. Preparation of the aperture 9 Stage 2. Fitting the Pitchglaze 11 Stage
More informationAcceptable Standards of Domestic Construction
Truss or Rafter Roof Batten Triple grip fastener (for roof trusses) Foil lined Insulation blanket Top plate Sprocket Brick tie Top plate strapping at 1200mm max. cts. Note: Holding down straps should be
More informationGV Standard PitchVent
GV Standard PitchVent Installation Manual Technical experts in the design, manufacture and supply of precision engineered, architectural rooflights for residential and commercial buildings. 202-INST v1.0
More informationINSTALL IN 2 DAYS. *Assumes 3-man fitting team. equinox. Tiled roof system. Installation guide ISSUE 1
INSTALL IN 2 DAYS *Assumes 3-man fitting team equinox Tiled roof system Installation guide ISSUE 1 Equinox tiled roof system Installation guide Contents Pre-installation checks 1. Installing the framework
More informationAttic Installation Tips:
Attic Installation Tips: Getting started: Installing Reach Barrier in the attic is a great DIY project and with the proper tools, a little practice and some professional tips most people can do it and
More informationInstallation Manual. This installation is for the Odyssey H1800 Series Ventilation System.
Installation Manual This installation is for the Odyssey H1800 Series Ventilation System. This installation is limited to roofs with pitches between 3 and 35. This instruction assumes that there is a power
More informationSpeedDeck. Fixing and Handling Guide
SpeedDeck Section 1 Delivery/Storing On Site/Handling l SpeedDeck is factory or on-site manufactured. l Straight SpeedDeck bundles are a maximum 1 tonne, sheets nestled and banded with polypropylene or
More informationThe Leka System Installation Guide
Installation Guide The Leka System Installation Guide The following guide has been created to assist in the fabrication and installation of the Leka System. Please note that each roof is individual and
More informationSPECIFICATION FOR. BRANZ Appraisal Certificate # 621 (2008)
SPECIFICATION FOR TEKTON WEATHERIZATION SYSTEM BRANZ Appraisal Certificate # 621 (2008) MW TWS 10/07/2012 Page 1 SYSTEM DESCRIPTION The Tekton Weatherization System consists of TEKTON Wall Underlay, Tekton
More informationAS TESTED TBA FIREFLY TBA FIREFLY BAL-FZ BUSHFIRE ROOF SYSTEM INSTALLATION GUIDE EASY TO INSTALL EASY TO CARRY EASY TO TRANSPORT
AS1530.8.2 TESTED BAL-FZ BUSHFIRE ROOF SYSTEM INSTALLATION GUIDE EASY TO TRANSPORT EASY TO INSTALL EASY TO CARRY Completely wrap the whole roof frame, including valleys, hips, ridges, fascia, eave, bargeboard
More informationInstallation guide. Step-by-step instructions
Installation guide Step-by-step instructions Contents Tools Required to Install p1 Screws & Fixings p2 Injection Moulded Solid Components p3 Components p4 Georgian Hips & Ancillaries p5 Fixing Eaves Beam
More information1. Tile Roof Installation:!
1. Tile Roof Installation:! * Solar Roof Fan have a different base plate and ventilation opening size. This will require different measurements and allowances to those shown as pictures. Materials Needed:
More informationGuardian warm roof conversion system. Installation Guide
Guardian warm roof conversion system Installation Guide 2 www.guardianroof.co.uk Conservatory walls consist largely of glazed elements including windows and doors that may include structural mullions or
More informationSANERI 3 º. Self-adhesive SBS-elastomer bitumen cap sheet
SANERI 3 º Self-adhesive SBS-elastomer bitumen cap sheet 0809 www.katepal.fi 06 EN 13707 Producer: KATEPAL OY P. O. Box 33 FI-37501 LEMPÄÄLÄ FINLAND Tel. +358 (0)3 375 9111 Fax +358 (0)3 375 0974 E-mail:
More informationInstructions for Installation on a Pitched Roof LIGHTWAY optical tube LW 260, LW 320, LW 520, LW 760
Lightway, s.r.o. Registered office: Ledvinova 1714, 149 00 Praha 4 Offices: Za Humny 1054/4a, 161 00 Praha 6 tel.: 235 300 694, fax: 235 300 218 Company ID No.: 63669366, Tax ID No.: CZ63669366 Bank: KB
More informationInstallation guide for 20/20
Introduction The following installation instructions are recommended minimum requirements for the 20/20. The designer and fixer should ensure that tiles are installed in accordance with BS 5534; The British
More informationInstallation Guide. Guardian Slate Roof System. England, Scotland & Wales
Installation Guide Guardian Slate Roof System England, Scotland & Wales March 2016 Product Information Construction: Manufactured from resin bonded crushed limestone Size (slate): 445 x 294mm (ridgecap):
More informationEgger Roofing Board Fast, Easy, Safe: With this board you can reach the top.
Egger Roofing Board Fast, Easy, Safe: With this board you can reach the top. 1 2 Content Content 1 2 Roof Sheathing 4 Importance 4 EGGER Roofing Board 5 Benefits 5 Principles of the EGGER Roofing Board
More informationCOMPONENTS OF THE CLICKFAST FASCIA AND GUTTER SYSTEM 5: INTERNAL MITRE
INTRODUCING THE CLICKFAST FASCIA AND GUTTER SYSTEM The Clickfast Fascia and Gutter System was originally designed by Stratco and has proven to be the most successful fascia and gutter system in Australia
More informationGROWING BETTER THROUGH DESIGN. 6ft Lean-To LEAN-TO. Assembly Instructions 04/02
GROWING BETTER THROUGH DESIGN 6ft Lean-To LEAN-TO Assembly Instructions 04/02 6ft Lean-To Greenhouse Base Plan Introduction/Tools/Contents / / Contents This is a copy of our Lean-To greenhouse base plan.
More informationPROFESSIONAL PITCHED ROOFING ANCILLARIES
PROFESSIONAL PITCHED ROOFING ANCILLARIES MADE IN BRITAIN Before installing the Easy Roof System, please be aware of the following guidelines: The roof should be installed in the traditional way, with the
More informationInstructions for Installation on a Flat Roof
Lightway, s.r.o. Registered office: Ledvinova 1714, 149 00 Praha 4 Offices: Za Humny 1054/4a, 161 00 Praha 6 tel.: 235 300 694, fax: 235 300 218 Company ID No.: 63669366, Tax ID No.: CZ63669366 Bank: KB
More informationINSTALLATION INSTRUCTIONS for TB6.2,TB7.0, TB7.8 & TB8.4
the unique loft conversion & flooring system INSTALLATION INSTRUCTIONS for TB6.2,TB7.0, TB7.8 & TB8.4 Unit 6, Devizes Trade Centre, Hopton Park, Devizes, Wiltshire, SN10 2EH t 01380 739000 e info@telebeam.co.uk
More informationInstallation Guidelines
TM TM Installation Guidelines * Guidelines also apply to installation of astroeco products More For Pre-Engineered Metal and Post-Frame Buildings icient, Safer To Use and Easier To Install Than Regular
More informationInspire Aledora Slate Application Guidelines
July 2014 Inspire Aledora Slate Application Guidelines Only Basic Roofing Tools Required Hand fastened or fastened with a pneumatic nail gun Utility knife or a standard circular saw Tape measure, pry bar,
More informationDETAILS KOMPROMENT DANISH BUILDING DESIGN ZAPPA
DETAILS KOMPROMENT DANISH BUILDING DESIGN ZAPPA 00 0 0 0 0 0 0 Z-0 - Elevation : 0 At the bottom, the first batten must be mounted according to detal Z- Slate size Batten distance 00 x 00 mm 0 mm -0, +
More information... the reflective insulation!
... the reflective insulation! Warm in winter, fresh in summer recycable Staple 20 mm Adhesive Aluthermo Insulation Aluthermo Rafter Micro-perforated underlayer without battening with battening Lathing
More informationVerge Flashing. Verge Flashing. Only use if flashings requirements can be site measured before ordering. Verge Clip
Tolerance Detail (recommended) Verge Closure Verge Channel Verge Clip Verge Flashing VERGE CHANNEL RIVETTED TO EUROSEAM AT APPROX 400MM CENTRES USING 4.8 X 12MM RIVETS. NB: DO NOT RIVET AT HALTER POSITION
More informationNAIMA. Insulation Between (filling) Purlins and Over Purlins. What Does Metal Building Insulation Do? Installation Instructions for New Construction
Installation Instructions for New Construction Step 8: Insulation Installation Insulation Between (filling) Purlins and Over Purlins Insulation between the Purlin Cavities Unroll and place unfaced metal
More informationOptiLiner Banded Liner System Bi-Directional Banding
TOP LAYER UNFACED INSULATION ROOF SHEET ING LINER BOTTOM LAYER UNFACED INSULATION General Introduction The is designed to provide maximum thermal performance in preengineered metal buildings using Owens
More informationHow-To-build guide Garden shed
How-To-build guide Garden shed What you can build using this guide This guide will show you how to build a re-locatable garden shed. Before you begin building Contact your local territorial authority to
More informationInspire Slate Starter Piece Hip and Ridge. 13 1/2" Height: 13 ½" Width: 12" Squares/ Pallet. Bundles/ Square
December 2017 Classic Slate Application Guidelines Only Basic Roofing Tools Required Hand fastened or fastened with a pneumatic nail gun Utility knife or a standard circular saw Tape measure, pry bar,
More informationInsuvent Designed to ensure ventilation in existing roofs when insulation quilts are installed
Insuvent Designed to ensure ventilation in existing roofs when insulation quilts are installed 100mm 100mm 100mm Varies For ensuring adequate ventilation as a retrofit when additional layers of insulation
More informationA Shell construction
A Shell construction A 4/2012 Content 1 BASE AND WALL ANCHORING 1.1 Base with mortar bed 1.2 Base with sill plate 1.3 Base with raised sill plate 1.4 Concrete base (mortar bed) 1.5 Concrete base (sill
More informationTEKTON WEATHERIZATION SYSTEM SPECIFICATION
MWNZ Tekton Weatherization System AUG 2017 TEKTON WEATHERIZATION SYSTEM SPECIFICATION SYSTEM DESCRIPTION The Tekton Weatherization System consists of TEKTON Wall Underlay, Tekton SEAM TAPE, TRADE-SEAL
More informationInstallation Instructions
Installation Instructions RAPID RIDGE STANDARD / 7 / METRIC Page Installation Considerations 3 Rapid Ridge Standard General Installation 4 Rapid Ridge Metric General Installation 5 Rapid Ridge 7 General
More informationROOFING DESIGN AND FIXING GUIDE
CUPA PIZARRAS leads the world in slate production. Our 16 quarries and 22 processing plants combine the latest technology with our traditional know-how and craftsmanship. Using cutting-edge production
More informationInstallation Instructions for New Construction. Installation Instructions for New Construction
Installation Instructions for New Construction Installation Instructions for New Construction Step 1: Receipt and Inspection of Material Step 2: Banding Preparation Step 3: Parallel Band Installation Step
More informationThe Firestone QuickSeam Reinforced Perimeter Fastening Strip needs to be installed with appropriate fasteners at maximum centres of 300 mm.
3.3 Base Tie-in 3.3.1 Base Tie-in General In order to account for structural movement of the substrate, stresses inherent in the handling and production of elastomeric sheets and thermal variations, the
More informationIMAGINATION SOLAR LTD. Installation Guide A1. Planning The Collector Installation
Page 1 of 6 IMAGINATION SOLAR LTD Installation Guide A1 Planning The Collector Installation Unit 4 Montpelier Central, Station Road Bristol BS6 5EE t: 0117 943 6668 f: 0117 942 8998 e: enquiries@imaginationsolar.com
More informationROOF FRAMING INFORMATION BATTEN INSTALLATION CORONA SHAKE INSTALLATION ACCESSORY INSTALLATION ESTIMATING DATA GENERAL INFORMATION
ROOF FRAMING INFORMATION BATTEN INSTALLATION CORONA SHAKE INSTALLATION ACCESSORY INSTALLATION ESTIMATING DATA GENERAL INFORMATION ROOF FRAMING INFORMATION It is the responsibility or roofers, building
More informationOptiLiner Banded Liner System Bi-Directional Banding
TOP LAYER UNFACED INSULATION ROOF SHEET LINER BOTTOM LAYER UNFACED INSULATION General Introduction The OptiLiner Banded Liner System is designed to provide maximum thermal performance in preengineered
More informationInstallation Instructions
Installation Instructions Alpha SolarSmart On Roof Kits for the Installation of Alpha Solar Collectors onto Tile and Slate Type Roofs For Technical help or for Service call... ALPHA HELPLINE Tel: 0 77
More informationtechnical bulletin Roofline Installation Details No.7 Fascia Installation Details Typical Eaves Details K16 Fascia & 9mm Vented Soffit
Roofline Installation Details This is intended to provide you with a brief overview of the popular products in Kestrel s Roofline range, where they can be used and the main criteria for installation. Typical
More informationShingle Installation Guide
Installation Guide Roof Framing Information Installation Installation Accessory Installation Estimating Data General Information Roof Framing Information It is the responsibility or roofers, building contractors
More informationUniversal Installation Instructions. Preparation and Safety Information. Natural Lighting by Monodraught. Dust. Scaffolding
Natural Lighting by Monodraught Universal Installation Instructions Preparation and Safety Information Scaffolding For flat roofs and single storey buildings not exceeding 10 ft. ( m) in height, access
More informationequinox INSTALLATION GUIDE Issue CONTENTS If in doubt at any stage BE SAFE WHEN WORKING AT HEIGHT
equinox INSTALLATION GUIDE Issue 3 CONTENTS 1. Preparing the ring beam 2 2. Installing the eaves beam 3 3. How to install structural support posts 7 4. Insulating and waterproofing 8 5. Tile application:
More informationThis installation guide has been created to assist in constructing a Liniar conservatory roof from a kit format.
1.00 - Introduction This installation guide has been created to assist in constructing a Liniar conservatory roof from a kit format. Please note, each roof has been individually designed to meet specific
More informationDry Verge System. For more information on CEMEX visit
Dry Verge System The Russell Dry Verge System is a high quality purpose designed mechanically fixed and mortarless verge finish which requires no maintenance. It comprises of: Individual units for left
More informationTECHNICAL BULLETIN 28
November 2015 TECHNICAL BULLETIN 28 INCLINED PREFORMED GRP VALLEY TROUGHS 1. BACKGROUND 1.1 Preformed GRP (Glass Reinforced Polyester) Valley Troughs have been used successfully in the roofing industry
More informationInclined Roof System Trimoterm SNV
Inclined Roof System Trimoterm SNV Inclined Roof System Trimoterm SNV - Technical Document EN Version 6 July 2016 TABLE OF CONTENTS 1 Technical Description of Roof System Trimoterm SNV 1 1.1 General 1
More informationCROSSBAR RAFTER ISOMETRIC
Super Sky Products' typical glazing system consists of glass panels or "lites" which are attached to the main framing members using extruded aluminum "retainers" or "pressure plates". These retainers are
More informationtechnical bulletin Roofline Installation Details No.7 Fascia Installation Details Typical Eaves Details K16 Fascia & 9mm Vented Soffit
Roofline Installation Details This is intended to provide you with a brief overview of the popular products in Kestrel s Roofline range, where they can be used and the main criteria for installation. Typical
More informationTimber joist. Timber joist ceilings and separating / compartment floors. Timber joist.
ceilings and separating / compartment floors Ceilings to timber joist floors are an established form of ceiling construction, widely used in both new housing and refurbishment. Separating / compartment
More informationItem Checklist & Additional Tools Required For Installation
Product Manual Item Checklist & Additional Tools Required For Installation Included Parts: Qty: 1 Maestro BAL Ventilator 1 2 Speed Controller 1 3 Power Supply 1 4 Fixing Strap 1 5 Speed Controller Fixing
More informationBase : (1 - batten spacing, 2 - bottom row batten spacing, 3 - ECOTILE, 4 - batten, 5 - rafter, 6 - fixing method)
ECOTILE is an interlocking stamp tile with side cuts and 2 pins. Dimensions 405 x 318 mm Groove Depth 5 mm Pins Height 15 mm Coverage 10 tiles per m² Weight 23, 4 Kg per m² Method for fitting the ECOTILE
More informationYWY M08 The new VELUX solution
YWY M08 The new VELUX solution VELUX roof windows and vertical window elements installed as a dormer in roof pitches between 42º and 52º YWY M08 is available as a double or triple unit and can be installed
More informationPRODUCT INFORMATION FOR ARCHITECTS, ENGINEERS AND INSTALLERS Insulation spacers for commercial metal roofing
www.roofrazor.com.au PRODUCT INFORMATION FOR ARCHITECTS, ENGINEERS AND INSTALLERS Insulation spacers for commercial metal roofing 1.0WHAT IS THE ROOF RAZOR? u The Roof Razor is a roof insulation spacer
More information4 Position the Suntile to the x tile s position and mark the felt around the square box flange. Then remove the Suntile
4 Position the Suntile to the x tile s position and mark the felt around the square box flange. Then remove the Suntile 5 Using a sharp bladed knife, cut through the felt from corner to corner in an x
More informationInstallation Manual for Thermo Panel
Installation Manual for Thermo Panel 1 About Thermo Panel is a building wrap, insulation, air and water barrier, mold inhibitor and cold bridge eliminator all-in-one. Delivering an R-value of up to 5 on
More informationFIXING GUIDE. Designed for Garages & Sheds, Houses, DIY, Flat Roofs, Industrial & Agricultural Buildings etc. IS THE LONG TERM ROOFING SOLUTION
FIXING GUIDE Designed for Garages & Sheds, Houses, DIY, Flat Roofs, Industrial & Agricultural Buildings etc. IS THE LONG TERM ROOFING SOLUTION Permaroof Permaroof Permaroof Profile Roofing Manufacturers
More informationCOLORBOND steel clad. Details for bushfire-prone AS BAL-FZ sites
FACT SHEET Version April 20 COLORBOND steel clad Details for bushfire-prone AS3959-2009 BAL-FZ sites This Fact Sheet describes a range of new steel clad roofing systems that have been designed for areas
More informationAQUAGARD EPDM FLAT ROOFING SYSTEMS INSTALLATION GUIDE THE MECHANICALLY FIXED SYSTEM
AQUAGARD EPDM FLAT ROOFING SYSTEMS INSTALLATION GUIDE THE MECHANICALLY FIXED SYSTEM The following guide covers the technique for the Mechanically Fixed System. This system is best employed when an overlay
More information10. Vents, Baffle Guard and Blocking
10. Vents, Baffle Guard and Blocking 10.1 INSTALLING BATH FAN AND END CAP 10.2 INSTALLING RANGE PLENUM AND END CAP 10.3 INSTALLING PROPER VENTS 10.4 INSTALLING WIND WASHING BAFFLE GUARD 10.5 INSTALLING
More informationfor Rigid Sun Lite Planning the layout
for Rigid Sun Lite These instructions refer to installations on a flat and pitched roof. Various roof flashing units are available according to the particular roof covering. The roof flashing will be boxed
More informationNEW HOME WARRANTY A REFERENCE GUIDE FOR TYPICAL WALL AND WINDOW DETAILS (RAINSCREEN SYSTEM) SHOWN AS FIBRE CEMENT CLADDING
NEW HOME WARRANTY A REFERENCE GUIDE FOR TYPICAL WALL AND WINDOW DETAILS (RAINSCREEN SYSTEM) SHOWN AS Reference Guide 0.1 GENERAL 0.1 Reference Guide 0.2 Index 0.3 Disclaimer & Limitations 0.4 General Notes
More information16ft Polytunnel Assembly Instructions
CONTENTS Section Page 1. FOUNDATION TUBES: Option A Ground Anchor Plates 3 2. FOUNDATION TUBES: Option B Concreted Foundation Tubes 5 3. STEEL FRAME ASSEMBLY & INSTALLATION 6 4. CROP BARS 8 5. TIMBER END
More informationinstallation guide Villa
installation guide Villa Table of Contents Introduction............................. 2 Safety................................... 2 Tools.................................... 2 Codes & Requirements....................
More informationfor Flexi Sun Lite Planning the layout
for Flexi Sun Lite These instructions refer to installations on a flat and pitched roof. Various roof flashing units are available according to the particular roof covering. The roof flashing will be boxed
More informationThree layer Felt Roofing using cold applied adhesive
Three layer Felt Roofing using cold applied adhesive Useful tips - Skill level - Safety - Felt Roofing Materials - Tools and Equipment Laying a felt roof is within the capabilities of most diy people providing
More informationJoshua Woodsman
CONSTRUCTION GUIDE of one of our design Please Note This electronic document is protected by the identifier against unauthorized dissemination on the Internet. Before building any structure make sure you
More informationTable of Contents. Fasteners... 4 Venting Preparation Installation with Battens - DECRA Tile & DECRA Shake 1
Table of Contents DECRA Tile & Shake Roof Overview... 2 Introduction... 3 Safety... 3 Tools.... 3 Estimating Sheets... 4 Codes & Requirements... 4 Roof Slope... 4 Underlayment... 4 Deck Preparation....
More informationFS 5800 EXPANSION JOINT EJ FIRE BARRIER* Installation Instructions
Thermal Structures Inc. FS 5800 EXPANSION JOINT EJ FIRE BARRIER* Installation Instructions FLOOR TO FLOOR (F) ROOF TO ROOF (R) FLOOR TO WALL (FW) ROOF TO WALL (RW) WALL TO WALL (W) CORNER WALL (CW) FLOOR
More informationClearly Solar Solar Thermal Flat Plate Collector Installation Instructions Horizontal In-roof mounting SRH 2.3
Clearly Solar Solar Thermal Flat Plate Collector Installation Instructions Horizontal In-roof mounting 22-75 SRH 2.3 www.glow-worm.co.uk 1 Guarantee Registration These Clearly Solar Flat Plate collectors
More informationSIM. Mass Loaded Vinyl
Mass Loaded Vinyl SIM Soundproofing INSTALLATION Manual When building sound isolated walls, floors and ceilings, we want to introduce significant non-resonant mass. MLV is an excellent source for this
More informationThe better way to build TM. Installation Manual ROOF SIPs
The better way to build TM Installation Manual ROOF SIPs August 2017 ROOF SIPs Installation Manual Table of Contents Topics General Requirements.................................... 3 Materials..............................................
More information15 YEAR GUARANTEE. Tough and long lasting Guaranteed waterproof for 15 years Economical and easy to fix AVAILABLE IN A RANGE OF COLOURS
INSTALLATION GUIDE AVAILABLE IN A RANGE OF COLOURS 15 YEAR GUARANTEE Tough and long lasting Guaranteed waterproof for 15 years Economical and easy to fix Coroline corrugated bitumen sheet is a tough lightweight
More information12ft Ultra Polytunnel Assembly Instructions
CONTENTS Section Page 1. FOUNDATION TUBES: Option A Hammered-In Foundation Tubes 3 2. FOUNDATION TUBES: Option B Ground Anchor Plates 4 3. FOUNDATION TUBES: Option C Concreted Foundation Tubes 5 4. STEEL
More informationCapella Gutter & Soffit
Page 1 Capella Gutter & Soffit For Customer Services (parts & delivery enquiries only) call: 01254 683 079 For Technical Support (installation queries) call: 0871 574 7293 Technical support calls cost
More information