Investigations on the Effectiveness of Self-tapping Screws in Reinforcing Bolted Timber Connections

Size: px
Start display at page:

Download "Investigations on the Effectiveness of Self-tapping Screws in Reinforcing Bolted Timber Connections"

Transcription

1 Investigations on the Effectiveness of Self-tapping Screws in Reinforcing Bolted Timber Connections Mohammad Mohammad Group Leader, Building Systems Forintek Canada Corp, Eastern Division Quebec, Canada Alexander Salenikovich Assistant Professor Faculty of Forestry & Geomatics, Laval University Quebec, Canada Pierre Quenneville Professor and head of Civil Engineering Department Royal Military College of Canada Kingston, Canada Summary Timber connections require particular consideration to prevent brittle failures. Various reinforcing techniques have been proposed over the years for bolted timber connections such as truss plates and fibre-reinforced composite (FRC) or internally reinforced using threaded rods and glued-in rods. Self-tapping screws have high withdrawal resistance and can easily be installed in timber members. This paper reports the results of a research program carried out to investigate the effectiveness of self-tapping screws in reinforcing bolted timber connections when loaded parallel to grain or perpendicular to grain. Various series of bolted glulam specimens of different configurations were tested with and without reinforcement, and their strength, stiffness, ductility, and failure modes were compared. 1. Introduction Connections in heavy timber structures play an essential role in providing stability and stiffness to the structure. The interruption of continuity in the timber structure caused by the presence of joints results in a decrease in the overall strength and stiffness of the structure which in turn implies an increase in the dimension of the assembled timber elements. In many cases, timber connection details govern the design of the various structural members. The efficient design and construction of such connections systems often determine the level of success of wooden buildings when compared to other buildings made of steel or concrete. Innovative timber connection systems have been developed over the years; however, those connection systems have proven to be either too expensive or difficult to fabricate. Bolted connections remain quite popular in timber structure designs due to their cost-effectiveness and ease of fabrication. However, certain configurations may produce brittle failures of the joints, which are not predictable in a rational form in the current design documents. Typical brittle failure modes in bolted timber connections are: shear plug, group tear-out and splitting due to excessive tensile

2 stresses perpendicular-to-grain (as the bolt wedges its way through the wood). Preventing these types of failure would enhance bolted connection capacity and maintain the overall integrity of a timber structure, thus, enabling wood to compete favorably with other engineering materials. Various reinforcing techniques have been proposed over the years for bolted timber connections. Examples of such reinforcing techniques include externally reinforced connections using truss metal plates [1], and fibre-reinforced composite (FRC) [2], [3] or internally reinforced using gluedin rods and threaded rods [4], [5]. Results showed that the reinforcement could significantly increase ductility and strength of the connection. Reinforcement methods using self-tapping screws have been investigated. Some of these studies focused on the reinforcement of notched beam supports [6]. Others looked at bolted wood-to-wood connections with side wooden members reinforced with self-tapping screws and developed a model to calculate the load in the reinforcing screws [7]. In all cases, results showed that reinforced specimens exhibited a very ductile failure mode whereas the non-reinforced specimens failed in a brittle manner. Investigations on the mechanical properties of self-tapping screws in wood were also carried out [8], where embedment strength, withdrawal strength, pull-through and bending capacity of self-tapping screws were determined for modeling purposes. Self-tapping screws have high withdrawal resistance and can easily be installed in timber members compared to other means of reinforcement which require surface preparations and drilling; therefore, they could become a good solution for reinforcing new connections or repair existing ones that are showing signs of cracking. This is particularly important for timber connections that are designed for high loads, because their details govern the overall design of other structural members. However, technical information on the effectiveness of self-tapping screws in the reinforcement of bolted timber connections and in comparison to other reinforcing techniques is not available at the moment. This paper reports some test results of various connection configurations with reduced end distances, with and without reinforcement. The goal of the study was to provide relevant information on use of self-tapping screws as means of reinforcement for bolted timber connections and/or as means of designing more compact joints. Results of this research will assist industry initiatives to promote the use of wood products in structural applications, especially in the commercial and industrial sectors where heavy timber connections are quite common. The results are also expected to serve as a useful benchmark for structural design professionals and code officials in pursuing the idea of using timber in structural systems for non-residential buildings. 2.0 Experimental Investigation 2.1 Materials All tested connections were steel-wood-steel type with steel side plates. The main members were from Spruce-Pine (SP) or Douglas-fir (DF) glued laminated timber (glulam), 20f-EX stress grade with a cross-section of 80x190 mm (4x8 in.) for the specimens loaded parallel to grain and 20f-E stress grade, 80x304 mm for the specimens loaded perpendicular to grain. In an effort to randomize any manufacturing/material flaws and to equally distribute the potential density variations amongst specimens, test groups were created by selecting pieces from several billets. For all test groups SAE Grade 2 bolts, 19 mm (3/4 in.) in diameter, were utilized (F y avg = 448 MPa, F u avg = 544 MPa). The steel side plates were of 300W grade, 9.5 mm (⅜ in.) thick. Two types of self-tapping screws were

3 used in the parallel to grain study. Type A screws were Simpson Strong-Drive wood screws, 6x152 mm in size, with a hex washer (trade name: SDS 1/4x6 ). Type B screws were produced by Screw Products Inc. These were 8x152 mm (5/16x6 in.) in size with ceramic-coated Star Drive flat head. Truss plates were 51x153 mm, SK-20 manufactured and provided by Jager Building Systems. For the perpendicular to grain tests, WURTH screws, 8x200 mm were used. All wood members were conditioned to attain 12% equilibrium moisture content prior to testing. 2.2 Test set-up Testing procedures outlined in [9] were followed. All connections were loaded until one of the ends of the joint failed. The failure was attained when one of the following conditions was reached: when the load dropped with no recovery, or due to excessive deformation. The failure was generally attained within 10 min. except with joints reinforced with truss plates, which failed at a very large slip, and it took up to 20 min. to reach failure. Load-slip data were measured with an electronic data acquisition system. A total of four displacement transducers (LVDT s) were utilised to record displacements. Typical specimens are shown in figure 1. End distance LVDT 4 Glulam LVDT 3 Self-tapping screw Self-tapping screws Parallel to grain Loading Self-tapping screws LVDT 2 LVDT 1 Self-tapping screws Perpendicular to grain Loading Fig 1 Test set up and specimen configurations 2.3 Specimens Specimen configurations have been selected in such a way to trigger brittle failure; i.e., row shearout or splitting for parallel to grain loading or splitting for perpendicular to grain loading. In total, 20 configurations were tested with ten specimens in each series. Table 1 gives details of specimen configurations and materials for the parallel to grain loading and Table 2 gives the details for the perpendicular to grain ones.

4 The Canadian design provisions for bolted timber connections [10] stipulates that the minimum end distance should not be lower than seven times the diameter of the bolt or 50 mm for a loaded end. For unloaded end, it should not be lower than four times the diameter of the bolt or 50 mm. A reduced loaded end distance (5d) was used in this study for most of specimens in order to investigate the impact of reinforcement on improving the ductility of connections with smaller end distances than those specified in the design norm. Table 1 Configurations of tested series parallel to grain loading Series Material No. of End No. of Bolt Row rows distance bolts/row spacing spacing Type of reinforcement 1 SP 80x d 1 N/A N/A No Reinforcement 2 SP 80x d 1 N/A N/A Screws type A 3 SP 80x d 1 N/A N/A Truss plate 4 DF 80x d 1 N/A N/A No Reinforcement 5 DF 80x d 1 N/A N/A Screws type A 6 SP 80x d 2 4d N/A No Reinforcement 7 SP 80x d 2 4d N/A Screws type A 8 SP 80x d 1 N/A 5d No Reinforcement 9 SP 80x d 1 N/A 5d Screws type A 10 SP 80x d 1 N/A 5d Truss plate 11 SP 80x d 1 N/A 5d No Reinforcement 12 SP 80x d 1 N/A 5d Screws type A 13 SP 80x d 1 N/A 5d Splits & screws type A 14 SP 80x d 1 N/A 5d Screws type B 15 SP 80x d 1 N/A 5d Two screws type A The configurations of the specimens loaded perpendicular to grain were selected to verify the effect of end distance on the splitting resistance and further, to verify if screws could be used to avoid potential brittle failures. For this paper, only the effect of screw reinforcement on the connection resistance will be reported. Table 2 Configurations of tested series perpendicular to grain loading Series Material No. of End No. of Bolt Loaded rows distance bolts/row spacing edge Type of reinforcement 16 SP 80x d 2 3d 4d No Reinforcement 17 SP 80x d 2 3d 4d 16 - Re-tested with screw 18 SP 80x d 2 3d 4d Screw 19 SP 80x d 2 3d 4d No Reinforcement 20 SP 80x d 2 3d 4d 19 - Re-tested with screw 3. Results and Discussion 3.1 Failure modes

5 The predominant failure mode in specimens loaded parallel to grain, with 5d end distance was row shear-out, except for those reinforced with metal truss plates (Series 3 and 10), in which considerable crushing of wood at the bolts was observed. Splitting was also prominent in many specimens with 5d end distance, especially, in those reinforced with self-tapping screws. Specimens with 7d end distance, with and without reinforcement, failed mainly in splitting. For Series 4 and 5 made with D-fir, the main type of failure was row shear-out. Even though, self-tapping screws did not seem to affect the failure mode in DF specimens with single bolts, they reduced the row shear failure in DF specimens with double bolts which failed in splitting. In Series 13, where the specimens with artificial splits were reinforced with self-tapping screws, the splitting propagated along the artificial splits under one or both bolts. Little evidence of wood crushing was observed. Generally, the crack propagation in non-reinforced joints was more pronounced than in the reinforced ones. In the specimens loaded perpendicular to grain, all failure modes involved splitting. For the ones reinforced with screws, head pull-through was observed. 3.2 Analysis of the load-slip profile The load-slip curve of the failed end was used to determine the following characteristic points: proportional limit (P PL, PL ), point of maximum resistance (P max, max ), and failure point (P fail, fail ), as shown in Figure 2. Load P PL PL Initial slope P max max Pfail fail Fig 2 Characterization of performance parameters of tested connections Initial slope range Slip According to [11], the yield point is determined as the intersection point between the load-slip curve and the straight line, which is offset 5% of the bolt diameter from the line of the initial slope. This approach was not suitable to characterize the joints tested in this project, because non-reinforced joints were brittle and did not exhibit a yield point, whereas in reinforced joints the 5% diameter offset was found deep in the nonlinear portion of the curve. For this reason, the transition to the plastic yielding was better characterized by the proportional limit (PL). To determine PL, a tangent line was fit to the load-slip curve for every ten data points above the initial slope range. The PL was determined as the point on the load-slip curve where the tangent line deviated at least 15% from the initial slope. 3.3 Ultimate loads As it can be seen in figure 3, the reinforcement with Type A screws did not affect the maximum load sustained by the joints for most series tested, regardless of the joint configuration. Neither Type B screws (Series 14) added significantly to the load capacity of the joints. No significant

6 differences in P max were observed between DF and SP specimens (Series 4 and 5 vs. Series 1 and 2). However, comparing Series 8 with Series 13, where the specimens with artificial splits were reinforced with screws, it was evident that the reinforcement of the damaged joint provided as much as 70% of the original load capacity assuming that the specimens with artificial splits had no strength at all. This is a significant contribution, especially for the repair of already split structural members. Table 3 Summary of test results parallel to grain loading Series P max fail max K ini ave P PL PL fail / PL Type of reinforcement kn mm mm kn/ mm kn mm No Reinforcement Screws type A Truss plate No Reinforcement Screws type A No Reinforcement Screws type A No Reinforcement Screws type A Truss plate No Reinforcement Screws type A Splits & screws type A Screws type B Two Screws type A Table 4 Summary of test results perpendicular to grain loading Series P max (kn) COV Type of reinforcement % No Reinforcement % Group 16 re-tested with screw % Screw % No Reinforcement % Group 19 re-tested with screw Reinforcement of single-bolt connections with metal truss plates (Series 3 vs. Series 1) did not affect the load capacity of the joint; however, the reinforced two-bolt connections (Series 10 vs. Series 8) showed on average 18% increase of the load capacity (see figure 3). One possible explanation for such an increase is that the truss plates resisted tensile stresses in the direction perpendicular to grain after some deformation had already occurred. With a single-bolt arrangement, row shear-out was predominant, and truss plates could not contribute much to prevent the formation of shear planes parallel to the load direction. With regards to connections tested perpendicular to grain, no significant statistical differences were observed between un-reinforced and reinforced groups. The only observation one could make is

7 that the mode of failure of the reinforced ones was screw head pull-through and this, forced the COV to be relatively lower. It is interesting to note that no differences existed between reinforced connections that were previously tested and then repaired and reinforced one that were previously un-tested. This again, leads one to confirm that the head pull-through controlled the ultimate load and that the tension strength perpendicular to grain of the member did not contribute to the connection resistance at ultimate. Pmax (kn) N/R Screw s type A Pmax (kn) N/R Screw s type A Truss plate Series Series (a) (b) Fig 3 Mean values of P max of tested series with (a) and without reinforcement (b) 3.4 Ductility Test results in Table 3 show that the ductility of joints is increased due to reinforcements. Ductility ratio N/R Screw s type A Truss plate Series Fig 4 Comparison of ductility ratio of specimens with and without reinforcements parallel to grain. 4. Conclusions Figure 4 shows that, on average, SP specimens reinforced with truss plates exhibited the highest ductility ratio, although DF specimens with screws (Series 5) were also highly ductile. Truss plates improved the residual strength of the tested connections due to crushing of wood prior to failure, and it was reflected by the large deformations on the load-slip curves. This improvement in the residual strength translates into more ductile connections, which are capable of absorbing more energy than non-reinforced ones. For critical joints in timber structures, this may be a valuable benefit during any seismic events. This study dealt with the experimental investigation of the effectiveness of self-tapping screws as means of reinforcing bolted timber connections loaded either parallel or perpendicular to grain. Twenty series of double-shear steel-wood-steel connections with one or two bolts per where tested. The specimens were reinforced with self-tapping screws or truss plates. Some of the specimens had artificial splits made with a band saw and were reinforced prior to testing.

8 Test results showed that reinforcement had positive effects on the joint ductility, whereas the load capacity and initial stiffness were not significantly affected. This was observed for parallel and perpendicular to grain loading. Reinforcement with either self-tapping screws or truss plates altered the failure mode in certain tests. A ductile failure mode with considerable crushing of wood was evident in connections reinforced with truss plates and for the perpendicular to grain specimens, screw head pull-through controlled the ultimate load. 5. References [1] Hockey, B. and F. Lam, and H.G.L. Prion Truss plate reinforced bolted connections in parallel strand lumber, Canadian Journal of Civil Engineering. 27: [2] Soltis, L. A., R.J. Ross, and D.F. Windorski Fiberglass-reinforced bolted wood connections, Forest Products Journal. 48(9): [3] Chen, C.J Mechanical behaviour of fiberglass reinforced timber joints, Ph.D. Thesis, No. 1940, EPFL. Lausanne, Switzerland. [4] Quenneville, J.H.P. and Mohammad, M Anti-check bolts as means of repair for damaged split ring connections, Proceedings of the World Conference on Timber Engineering. July 31-August 3. Whisler, BC, Canada. [5] Mastschuch, R Reinforced Multiple Bolt Timber Connections. M.Sc. Thesis, University of British Columbia, Vancouver, BC, Canada. [6] Blass, H.J. and Bejtka, I Reinforcement perpendicular to the grain using self-tapping screws, Proceedings of the 8th World Conference on Timber Engineering, Volume I, Lahti, Finland, [7] Blass, H.J. and M. Schmid. Self-tapping screws as reinforcement perpendicular to the grain in timber connections, In: Joints in Timber Structures. Proceedings of the International RILEM Symposium. RILEM Publications S.A.R.L. Stuttgart, Germany, [8] Hansen, K.F Mechanical properties of self-tapping screws and nails in wood, Canadian Journal of Civil Engineering. 29: [9] American Society for Testing and Materials D1761. Standard test methods for mechanical fasteners in wood. Annual Book of ASTM Standards. West Conshohocken, PA. [10] Canadian Standard Association Engineering Design in Wood (Limit States Design), O86-01, Rexdale, Ontario. [11] ASTM D5652. Standard test methods for bolted connections in wood and wood-based products. Annual Book of ASTM Standards. West Conshohocken, PA.

Anti-check bolts as means of repair for damaged split ring connections

Anti-check bolts as means of repair for damaged split ring connections Anti-check bolts as means of repair for damaged split ring connections Quenneville, J.H.P. 1 and Mohammad, M. 2 ABSTRACT There are numerous large span timber hangars dating back to the Second World War.

More information

Dowel connections in laminated strand lumber

Dowel connections in laminated strand lumber Dowel connections in laminated strand lumber Cranswick, Chad J. 1, M c Gregor, Stuart I. 2 ABSTRACT Laminated strand lumber (LSL) is a relatively new structural composite lumber. As such, very limited

More information

Connection and performance of two-way CLT plates

Connection and performance of two-way CLT plates Connection and performance of two-way CLT plates by Chao (Tom) Zhang George Lee Dr. Frank Lam Prepared for Forestry Innovation Investment 1130 W Pender St, Vancouver BC V6E 4A4 Timber Engineering and Applied

More information

Moment-Resisting Connections In Laminated Veneer Lumber (LVL) Frames

Moment-Resisting Connections In Laminated Veneer Lumber (LVL) Frames Moment-Resisting Connections In Laminated Veneer Lumber (LVL) Frames Andy van Houtte Product Engineer-LVL Nelson Pine Industries Nelson, NZ Andy Buchanan Professor of Civil Engineering Peter Moss Associate

More information

Lawrence A. Soltis, M. and Robert J. Ross, M. 1

Lawrence A. Soltis, M. and Robert J. Ross, M. 1 REPAIR OF WHITE OAK GLUED-LAMINATED BEAMS Lawrence A. Soltis, M. and Robert J. Ross, M. 1 Abstract Connections between steel side plates and white oak glued-laminated beams subjected to tension perpendicular-to-grain

More information

SCREWS WITH CONTINUOUS THREADS IN TIMBER CONNECTIONS

SCREWS WITH CONTINUOUS THREADS IN TIMBER CONNECTIONS SCREWS WITH CONTINUOUS THREADS IN TIMBER CONNECTIONS Prof. Dr.-Ing. H. J. Blaß, Dipl.-Ing. I. Bejtka Universität Karlsruhe (TH), Germany Abstract Screws, bolts and dowels loaded perpendicular to the fastener

More information

Simplified analysis of timber rivet connections

Simplified analysis of timber rivet connections Simplified analysis of timber rivet connections Stahl, Douglas C., 1 Begel, Marshall, 2 and Wolfe, Ronald W. 3 ABSTRACT Timber rivets, fasteners for glulam and heavy timber construction, have been used

More information

Tension Perpendicular to Grain Strength of Wood, Laminated Veneer Lumber, and a Wood Plastic Composite.

Tension Perpendicular to Grain Strength of Wood, Laminated Veneer Lumber, and a Wood Plastic Composite. Tension Perpendicular to Grain Strength of Wood, Laminated Veneer Lumber, and a Wood Plastic Composite. Tracy Hummer, Research Assistant J. Daniel Dolan, Professor Michael Wolcott, Professor Wood Materials

More information

Glued laminated timber beams repair.

Glued laminated timber beams repair. Glued laminated timber beams repair. Master s Degree Extended Abstract Ricardo Cardoso Henriques da Silva Keywords: glulam, delamination, self-tapping screw, plywood, repair November 2014 1. INTRODUCTION

More information

Connection Design Examples

Connection Design Examples Connection Design Examples Using the 2015 NDS (DES345) Lori Koch, P.E. Manager, Educational Outreach American Wood Council Adam Robertson, M.A.Sc., P.Eng. Manager, Codes and Standards Canadian Wood Council

More information

CHARACTERISTICS OF LUMBER-TO-LUMBER FRAMING CONNECTIONS IN LIGHT-FRAME WOOD STRUCTURES

CHARACTERISTICS OF LUMBER-TO-LUMBER FRAMING CONNECTIONS IN LIGHT-FRAME WOOD STRUCTURES CHARACTERISTICS OF LUMBER-TO-LUMBER FRAMING CONNECTIONS IN LIGHT-FRAME WOOD STRUCTURES Andi Asiz 1*, Lina Zhou 1, Ying Hei Chui 1 ABSTRACT: Connections are arguably the most important part of light-frame

More information

STRUCTURAL TIMBER DESIGN

STRUCTURAL TIMBER DESIGN STRUCTURAL TIMBER DESIGN to Eurocode 5 2nd Edition Jack Porteous BSc, MSc, DIC, PhD, CEng, MIStructE, FICE Director lack Porteous Consultancy and Abdy Kernlani BSc, MSc, PhD, CEng, FIStructE, FIWSc Professor

More information

Connection Philosophy. p NDS Chapter-by-chapter description Changes from previous editions Examples. Part 1: Member Design Webinar.

Connection Philosophy. p NDS Chapter-by-chapter description Changes from previous editions Examples. Part 1: Member Design Webinar. Outline ASD and LRFD with the 2005 NDS Part 2 Connection Design Presented by: John Buddy Showalter, P.E. Vice President, Technology Transfer Connection philosophy p NDS Chapter-by-chapter description Changes

More information

Connections in CLT Assemblies

Connections in CLT Assemblies Creating forest sector solutions www.fpinnovations.ca Connections in CLT Assemblies Cross Laminated Timber Symposium Vancouver, BC February 8-9, 2011 M. Mohammad Building Systems Wood Products Division

More information

Mechanical behavior of fiberglass reinforced timber joints

Mechanical behavior of fiberglass reinforced timber joints Mechanical behavior of fiberglass reinforced timber joints Chen, Chi-Jen 1 ABSTRACT The objective of this research is to investigate the mechanical performance of dowel-type timber joints reinforced by

More information

Pull-compression tests on glued-in metric thread rods parallel to grain in different timber species and laminated veneer lumber

Pull-compression tests on glued-in metric thread rods parallel to grain in different timber species and laminated veneer lumber COST FP1004 15-17 April 2015 Lisbon, Portugal Pull-compression tests on glued-in metric thread rods parallel to grain in different timber species and laminated veneer lumber Frank Hunger 1, Mislav Stepinac

More information

EFFECTS OF GEOMETRY ON MECHANICAL BEHAVIOR OF DOVETAIL CONNECTION

EFFECTS OF GEOMETRY ON MECHANICAL BEHAVIOR OF DOVETAIL CONNECTION EFFECTS OF GEOMETRY ON MECHANICAL BEHAVIOR OF DOVETAIL CONNECTION Gi Young Jeong 1, Moon-Jae Park 2, KweonHwan Hwang 3, Joo-Saeng Park 2 ABSTRACT: The goal of this study is to analyze the effects of geometric

More information

Space-frame connection for small-diameter round timber

Space-frame connection for small-diameter round timber Space-frame connection for small-diameter round timber Wolfe, Ronald W., 1 Gjinolli, Agron E., 1 and King, John R. 2 ABSTRACT To promote more efficient use of small-diameter timber, research efforts are

More information

Timber Rivet Connections Design Process for a Hanger Connection

Timber Rivet Connections Design Process for a Hanger Connection Timber Rivet Connections Design Process for a Hanger Connection RobertJ.Taylor,PhD,P.Eng.,Assoc.AIAand DavidM.Moses,PhD,P.Eng.,P.E.,LEED AP Introduction Timber rivet connections have been used successfully

More information

Dowel type joints Influence of moisture changes and dowel surface smoothness. Erik Serrano and Johan Sjödin, Växjö University, Sweden

Dowel type joints Influence of moisture changes and dowel surface smoothness. Erik Serrano and Johan Sjödin, Växjö University, Sweden Dowel type joints Influence of moisture changes and dowel surface smoothness Erik Serrano and Johan Sjödin, Växjö University, Sweden Background and introduction With the increased use of glulam in large-span

More information

THE EFFECT OF THREAD GEOMETRY ON SCREW WITHDRAWAL STRENGTH

THE EFFECT OF THREAD GEOMETRY ON SCREW WITHDRAWAL STRENGTH THE EFFECT OF THREAD GEOMETRY ON SCREW WITHDRAWAL STRENGTH Doug Gaunt New Zealand Forest Research Institute, Rotorua, New Zealand ABSTRACT Ultimate withdrawal values for a steel 16mm diameter screw type

More information

Bolt Spacing and End Distance of Bolted Connection of Laminated Veneer Lumber (LVL) Sengon

Bolt Spacing and End Distance of Bolted Connection of Laminated Veneer Lumber (LVL) Sengon Civil Engineering Dimension, Vol. 19, No. 1, March 2017, 1-6 ISSN 1410-9530 print / ISSN 1979-570X online DOI: 10.9744/CED.19.1.1-6 Bolt Spacing and End Distance of Bolted Connection of Laminated Veneer

More information

Dowel-type fasteners. Timber Connections. Academic resources. Introduction. Deferent types of dowel-type fasteners. Version 1

Dowel-type fasteners. Timber Connections. Academic resources. Introduction. Deferent types of dowel-type fasteners. Version 1 Academic resources Timber Connections Dowel-type fasteners Version 1 This unit covers the following topics: Deferent types of dowel-type fasteners Introduction There are four criteria designers should

More information

Tension Perpendicular to Grain Strength of Wood, Laminated Veneer Lumber (LVL), and Cross-Banded LVL (LVL-C)

Tension Perpendicular to Grain Strength of Wood, Laminated Veneer Lumber (LVL), and Cross-Banded LVL (LVL-C) Tension Perpendicular to Grain Strength of Wood, Laminated Veneer Lumber (LVL), and Cross-Banded LVL (LVL-C) M. Ardalany PhD candidate, Department of Civil and Natural Resources Engineering, University

More information

4-Bolt Wood-to-Steel Connections

4-Bolt Wood-to-Steel Connections The Effects of Row Spacing and Bolt Spacing in 6-Bolt and 4-Bolt Wood-to-Steel Connections By Michael A. Dodson This thesis submitted in partial fulfillment of the requirements for the degree of MASTER

More information

NAILED MORTISED-PLATE CONNECTIONS FOR SMALL-DIAMETER ROUND TIMBER 1. Kug-Bo Shim* Ronald W. Wolfe. Marshall Begel

NAILED MORTISED-PLATE CONNECTIONS FOR SMALL-DIAMETER ROUND TIMBER 1. Kug-Bo Shim* Ronald W. Wolfe. Marshall Begel NAILED MORTISED-PLATE CONNECTIONS FOR SMALL-DIAMETER ROUND TIMBER 1 Kug-Bo Shim* Research Scientist Department of Forest Products Korea Forest Research Institute Seoul, 130-712, Korea Ronald W. Wolfe General

More information

ICC-ES Evaluation Report

ICC-ES Evaluation Report ICC-ES Evaluation Report ESR-6 Reissued April, 009 This report is subject to re-examination in two years. www.icc-es.org (800) 4-6587 (56) 699-054 A Subsidiary of the International Code Council DIVISION:

More information

EVALUATION OF SCREWS USED IN LAMINATED VENEER LUMBER ROCKING CONNECTIONS

EVALUATION OF SCREWS USED IN LAMINATED VENEER LUMBER ROCKING CONNECTIONS EVALUATION OF SCREWS USED IN LAMINATED VENEER LUMBER ROCKING CONNECTIONS D. M. Carradine, M. P. Newcombe and A. H. Buchanan Dept. of Civil and Natural Resources Engineering, University of Canterbury, Private

More information

The predictive model for strength of inclined screws as shear connection in timber-concrete composite floor

The predictive model for strength of inclined screws as shear connection in timber-concrete composite floor The predictive model for strength of inclined screws as shear connection in timber-concrete composite floor F. Moshiri, C. Gerber, H.R. Valipour, R. Shrestha & K.I. Crews Centre for built infrastructure,

More information

Available online at ScienceDirect. Procedia Engineering 114 (2015 )

Available online at  ScienceDirect. Procedia Engineering 114 (2015 ) Available online at www.sciencedirect.com ScienceDirect Procedia Engineering 114 (2015 ) 240 247 1st International Conference on Structural Integrity Dowel type joints of round timber exposed to static

More information

ADDENDUM (February 2014) 2012 NDS Changes John Buddy Showalter, P.E., Bradford K. Douglas, P.E., Philip Line, P.E., and Peter Mazikins, P.Eng.

ADDENDUM (February 2014) 2012 NDS Changes John Buddy Showalter, P.E., Bradford K. Douglas, P.E., Philip Line, P.E., and Peter Mazikins, P.Eng. ADDENDUM (February 2014) 2012 NDS Changes John Buddy Showalter, P.E., Bradford K. Douglas, P.E., Philip Line, P.E., and Peter Mazikins, P.Eng. 1) Add to section on Dowel-type Fasteners as follows: Section

More information

Moment resistance of bolted timber connections with perpendicular to grain reinforcements

Moment resistance of bolted timber connections with perpendicular to grain reinforcements Moment resistance of bolted timber connections with perpendicular to grain reinforcements Frank LAM Ph.D. P.Eng., Professor The University of British Columbia Vancouver, BC, Canada Michael SchulteWREDE

More information

Load carrying capacity of dowelled connections

Load carrying capacity of dowelled connections Load carrying capacity of dowelled connections H.J. Blass, Karlsruhe Institute of Technology F. Colling, Augsburg University of Applied Sciences Keywords: Dowel, yield moment, connection 1 Introduction

More information

EVALUATING ROLLING SHEAR STRENGTH PROPERTIES OF CROSS LAMINATED TIMBER BY TORSIONAL SHEAR TESTS AND BENDING TESTS

EVALUATING ROLLING SHEAR STRENGTH PROPERTIES OF CROSS LAMINATED TIMBER BY TORSIONAL SHEAR TESTS AND BENDING TESTS EVALUATING ROLLING SHEAR STRENGTH PROPERTIES OF CROSS LAMINATED TIMBER BY TORSIONAL SHEAR TESTS AND BENDING TESTS Minghao Li 1, Frank Lam 2, and Yuan Li 3 ABSTRACT: This paper presents a study on evaluating

More information

The Behaviour Of Round Timber Sections Notched Over The Support On The Tension Face. Justin Dewey

The Behaviour Of Round Timber Sections Notched Over The Support On The Tension Face. Justin Dewey The Behaviour Of Round Timber Sections Notched Over The Support On The Tension Face Justin Dewey Need for research In Queensland there are approximately 400 timber bridges still in use. Very little research

More information

Glulam Connection Details

Glulam Connection Details T E C H N I C A L N O T E Glulam Connection Details Note: This version is superseded by a more current edition. Check the current edition for updated design and application recommendations. ENGINEERED

More information

LATERAL LOADS OF STAPLED GLUED SURFACE-TO-SURFACE JOINTS IN ORIENTED STRANDBOARD FOR FURNITURE. Samet Demirel. Onder Tor. Xiaohong Yu* Jilei Zhang*

LATERAL LOADS OF STAPLED GLUED SURFACE-TO-SURFACE JOINTS IN ORIENTED STRANDBOARD FOR FURNITURE. Samet Demirel. Onder Tor. Xiaohong Yu* Jilei Zhang* LATERAL LOADS OF STAPLED GLUED SURFACE-TO-SURFACE JOINTS IN ORIENTED STRANDBOARD FOR FURNITURE Samet Demirel Assistant Professor Department of Forest Industrial Engineering Faculty of Forestry Karadeniz

More information

PRO LIGNO Vol. 11 N pp

PRO LIGNO Vol. 11 N pp FINITE ELEMENT SIMULATION OF NAILED GLULAM TIMBER JOINTS Mats EKEVAD Luleå University of Technology Division of Wood Science and Engineering SE-931 87 Skellefteå, Sweden Tel: +46 910 585377; E-mail: mats.ekevad@ltu.se

More information

Bolts and Set Screws Are they interchangeable?

Bolts and Set Screws Are they interchangeable? 1903191HA Bolts and Set Screws Are they interchangeable? Prof. Saman Fernando Centre for Sustainable Infrastructure SUT Introduction: This technical note discusses the definitions, standards and variations

More information

MAT105: Floor Framing

MAT105: Floor Framing MAT105: Copyright 2007 American Forest & Paper Association, Inc. Because the common applications for wood framing are in residential construction, the details of this program will be based on the IRC which

More information

Attach Trusses and Rafters Faster

Attach Trusses and Rafters Faster Attach Trusses and Rafters Faster SDWC TRUSS Screw Truss-to-Plate Connections For Truss-to-Plate Connections The Strong-Drive SDWC TRUSS screw provides a truss- and rafter-to-top-plate connection. The

More information

Korean standards of visual grading and establishing allowable properties of softwood structural lumber

Korean standards of visual grading and establishing allowable properties of softwood structural lumber Korean standards of visual grading and establishing allowable properties of softwood structural lumber Park, Moon-Jae 1, Shim, Kug-Bo 1 ABSTRACT Korean standards related to wood products such as "Sizes

More information

Design of structural connections for precast concrete buildings

Design of structural connections for precast concrete buildings BE2008 Encontro Nacional Betão Estrutural 2008 Guimarães 5, 6, 7 de Novembro de 2008 Design of structural connections for precast concrete buildings Björn Engström 1 ABSTRACT A proper design of structural

More information

VERSA-LAM. An Introduction to VERSA-LAM Products

VERSA-LAM. An Introduction to VERSA-LAM Products 44 VERSA-LAM An Introduction to VERSA-LAM Products VERSA-LAM is one of the strongest and stiffest engineered wood products approved in the UK. 241 302 356 406 VERSA-LAM products are excellent as floor

More information

Ductility of large-scale dowelled CLT connections under monotonic and cyclic loading

Ductility of large-scale dowelled CLT connections under monotonic and cyclic loading Ductility of large-scale dowelled CLT connections under monotonic and cyclic loading Lisa-Mareike Ottenhaus 1, Minghao Li 2, Tobias Smith 3 1. PhD candidate, Department of Civil and Natural Resources Engineering,

More information

Three-dimensional finite element analysis of the Japanese traditional post-and-beam connection

Three-dimensional finite element analysis of the Japanese traditional post-and-beam connection J Wood Sci (2011) 57:119 125 The Japan Wood Research Society 2010 DOI 10.1007/s10086-010-1151-0 ORIGINAL ARTICLE Jung-Pyo Hong J. David Barrett Frank Lam Three-dimensional finite element analysis of the

More information

Double Shear Testing of Bolts

Double Shear Testing of Bolts University of Wollongong Research Online Coal Operators' Conference Faculty of Engineering and Information Sciences 23 Double Shear Testing of Bolts N. Aziz University of Wollongong, naj@uow.edu.au D.

More information

2002 ADDENDUM to the 1997 NDS and PRIOR EDITIONS

2002 ADDENDUM to the 1997 NDS and PRIOR EDITIONS AMERICAN FOREST & PAPER ASSOCIATION American Wood Council Engineered and Traditional Wood Products March 2002 2002 ADDENDUM to the 1997 NDS and PRIOR EDITIONS The 2001 Edition of the National Design Specification

More information

Effect of Vertical Load under Cyclic Lateral Load Test for Evaluating Sugi CLT Wall Panel

Effect of Vertical Load under Cyclic Lateral Load Test for Evaluating Sugi CLT Wall Panel Effect of Vertical Load under Cyclic Lateral Load Test for Evaluating Sugi CLT Wall Panel Minoru OKABE 1, Motoi YASUMURA 2, Kenji KOBAYASHI 3, Takeshi HARAMIISHI 4, Yo NAKASHIMA 5, Kazuhiko FUJITA ABSTRACT:

More information

Lawrence A. Soltis. James K. Little

Lawrence A. Soltis. James K. Little ANGLE TO GRAIN STRENGTH OF DOWEL-TYPE FASTENERS Lawrence A. Soltis Supervisory Research Engineer Forest Products Laboratory,' Forest Service U.S. Department of Agriculture, Madison, WI 53705 Suparman Karnasudirdja

More information

National Design Specification for Wood Construction. Copyright Materials. Learning Objectives

National Design Specification for Wood Construction. Copyright Materials. Learning Objectives National Design Specification for Wood Construction The Wood Products Council is a Registered Provider with. Credit(s) earned on completion of this program will be reported to AIA/CES for AIA members.

More information

PERFORMANCE OF FASTENERS IN WOOD

PERFORMANCE OF FASTENERS IN WOOD COMPOSITES AND MANUFACTURED PRODUCTS PERFORMANCE OF FASTENERS IN WOOD FLOUR-THERMOPLASTIC COMPOSITE PANELS ROBERT H. FALK* DANIEL J. Vos STEVEN M. CRAMER* BRENT W. ENGLISH ABSTRACT In the building community,

More information

APA Performance Rated Rim Boards

APA Performance Rated Rim Boards D a t a F i l e APA Performance Rated Rim Boards A Rim Board is the wood component that fills the space between the sill plate and bottom plate of a wall or, in second floor construction, between the top

More information

Title. CitationJournal of Wood Science, 58(4): Issue Date Doc URL. Rights. Type. File Information.

Title. CitationJournal of Wood Science, 58(4): Issue Date Doc URL. Rights. Type. File Information. Title Effective lateral resistance of timber-plywood-timbe Author(s)Wanyama, Okumu Gordon; Sawata, Kei; Hirai, Takuro; K CitationJournal of Wood Science, 58(4): 315-321 Issue Date 2012-08 Doc URL http://hdl.handle.net/2115/50078

More information

Comparison of behaviour of laterally loaded round and squared timber bolted joints

Comparison of behaviour of laterally loaded round and squared timber bolted joints Focussed on Modelling in Mechanics Comparison of behaviour of laterally loaded round and squared timber bolted joints Antonín Lokaj, Kristýna Klajmonová VŠB echnical University of Ostrava, Faculty of Civil

More information

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC AND COMPOSITE FASTENINGS REPORT HOLDER: DEWALT

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC AND COMPOSITE FASTENINGS REPORT HOLDER: DEWALT 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-3164 Reissued 09/2017 This report is subject to renewal 09/2018. DIVISION: 06 00

More information

Connection Solutions for Wood-frame Structures. Copyright Materials. Learning Objectives

Connection Solutions for Wood-frame Structures. Copyright Materials. Learning Objectives Connection Solutions for Wood-frame Structures Presented by: John Buddy Showalter, P.E. Vice President, Technology Transfer The Wood Products Council is a Registered Provider with. Credit(s) earned on

More information

Butt Two pieces of wood meeting with flat sides adjoining usually at right angles. Some type of connector is needed to prevent movement.

Butt Two pieces of wood meeting with flat sides adjoining usually at right angles. Some type of connector is needed to prevent movement. Wood Connections There are basically five different types of connectors: Interlocking (carpentry joints), Dowel, Metal Connectors, Special Formed Connectors and Adhesives. I Interlocking (Carpentry Joints)

More information

eb^sv=qfj_bo UNIVERSITY OF WISCONSIN - STOUT COLLEGE OF SCIENCE TECHNOLOGY ENGINEERING & MATHEMATICS Architectural Technology AEC 233

eb^sv=qfj_bo UNIVERSITY OF WISCONSIN - STOUT COLLEGE OF SCIENCE TECHNOLOGY ENGINEERING & MATHEMATICS Architectural Technology AEC 233 eb^sv=qfj_bo UNIVERSITY OF WISCONSIN - STOUT COLLEGE OF SCIENCE TECHNOLOGY ENGINEERING & MATHEMATICS Architectural Technology AEC 233 Dr. Jason E. Charalambides fkqolar`qflk Heavy timber construction consists

More information

Detection and Assessment of Wood Decay in Glulam Beams Using a Decay Rate Approach: A Review

Detection and Assessment of Wood Decay in Glulam Beams Using a Decay Rate Approach: A Review In: Proceedings of the 18th International Nondestructive Testing and Evaluation of Wood Symposium held on Sept. 24-27, 2013, in Madison, WI. Detection and Assessment of Wood Decay in Glulam Beams Using

More information

THE ENGINEERED WOOD ASSOCIATION

THE ENGINEERED WOOD ASSOCIATION D A T A F I L E APA Performance Rated Rim Boards A rim board is the wood component that fills the space between the sill plate and bottom plate of a wall or, in second floor construction, between the top

More information

The Wood Products Council is a Registered Provider with. . Credit(s) earned on completion of this program will be

The Wood Products Council is a Registered Provider with. . Credit(s) earned on completion of this program will be Connection Solutions for Wood-frame Structures Presented by: John Buddy Showalter, P.E. Vice President, Technology Transfer The Wood Products Council is a Registered Provider with. Credit(s) earned on

More information

Module 10 : Improvement of rock mass responses. Content

Module 10 : Improvement of rock mass responses. Content IMPROVEMENT OF ROCK MASS RESPONSES Content 10.1 INTRODUCTION 10.2 ROCK REINFORCEMENT Rock bolts, dowels and anchors 10.3 ROCK BOLTING MECHANICS Suspension theory Beam building theory Keying theory 10.4

More information

4) Verify that the size of the supporting member can accommodate the connector s specified fasteners.

4) Verify that the size of the supporting member can accommodate the connector s specified fasteners. DESIGN NOTES 1) Allowable loads for more than one direction for a single connection cannot be added together. A design load which can be divided into components in the directions given must be evaluated

More information

Screw Withdrawal A Means to Evaluate Densities of In-situ Wood Members

Screw Withdrawal A Means to Evaluate Densities of In-situ Wood Members Screw Withdrawal A Means to Evaluate Densities of In-situ Wood Members Zhiyong Cai Assistant Professor, Dept. of Forest Science, Texas A&M University, College Station, Texas, USA Michael O. Hunt Professor

More information

Splitting strength of beams loaded perpendicular to grain by connections, a fracture mechanical approach

Splitting strength of beams loaded perpendicular to grain by connections, a fracture mechanical approach Splitting strength of beams loaded perpendicular to grain by connections, a fracture mechanical approach Ad Leijten Civil Eng. PhD, Senior Researcr University of Techn. Delft Delft, T Netrlands A.Leijten@citg.tudelft.nl

More information

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER: DEWALT EVALUATION SUBJECT:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER: DEWALT EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-3042 Reissued 09/2018 This report is subject to renewal 09/2019. DIVISION: 06 00

More information

WITHDRAWAL AND LATERAL STRENGTH OF THREADED NAILS

WITHDRAWAL AND LATERAL STRENGTH OF THREADED NAILS 238 WITHDRAWAL AND LATERAL STRENGTH OF THREADED NAILS Douglas R. Rammer, Donald A. Bender, and David G. Pollock An experimental study on the performance of threaded nails was conducted to understand and

More information

WoodWorks Connection Design Workshop

WoodWorks Connection Design Workshop WoodWorks Connection Design Workshop Bernhard Gafner, Struct.Eng, P.Eng, MIStructE, Dipl. Ing. FH/STV bernhard@aspectengineers.com Adam Gerber, P.Eng, M.A.Sc. adam@aspectengineers.com Disclaimer: This

More information

nineteen Wood Construction 1 and design APPLIED ARCHITECTURAL STRUCTURES: DR. ANNE NICHOLS FALL 2016 lecture STRUCTURAL ANALYSIS AND SYSTEMS ARCH 631

nineteen Wood Construction 1 and design APPLIED ARCHITECTURAL STRUCTURES: DR. ANNE NICHOLS FALL 2016 lecture STRUCTURAL ANALYSIS AND SYSTEMS ARCH 631 APPLIED ARCHITECTURAL STRUCTURES: STRUCTURAL ANALYSIS AND SYSTEMS DR. ANNE NICHOLS FALL 2016 lecture nineteen wood construction and design Wood Construction 1 Timber Construction all-wood framing systems

More information

PERFORMANCE OF COMPOSITE SHEAR WALL PANEL OF LVL AND GRC BOARD

PERFORMANCE OF COMPOSITE SHEAR WALL PANEL OF LVL AND GRC BOARD PERFORMANCE OF COMPOSITE SHEAR WALL PANEL OF LVL AND GRC BOARD Maryoko Hadi 1, Rudi Setiadji 2, Anita Firmanti 3, Bambang Subiyanto 4, Kohei Komatsu 5 ABSTRACT: The low-cost housing for the people is the

More information

Welded connections Welded connections are basically the same design in AISI as in AISC. Minor differences are present and outlined below.

Welded connections Welded connections are basically the same design in AISI as in AISC. Minor differences are present and outlined below. Cold-Formed Steel Design for the Student E. CONNECTIONS AND JOINTS E1 General Provisions Connections shall be designed to transmit the maximum design forces acting on the connected members. Proper regard

More information

Threaded Fasteners 2. Shigley s Mechanical Engineering Design

Threaded Fasteners 2. Shigley s Mechanical Engineering Design Threaded Fasteners 2 Bolted Joint Stiffnesses During bolt preload bolt is stretched members in grip are compressed When external load P is applied Bolt stretches further Members in grip uncompress some

More information

4.0 MECHANICAL TESTS. 4.2 Structural tests of cedar shingles

4.0 MECHANICAL TESTS. 4.2 Structural tests of cedar shingles 4.0 MECHANICAL TESTS 4.1 Basis for the test methodology The essence of deterioration is that while it may be caused by insects, weather, fungi or bacteria, the decay is not identical. Further, no two physical

More information

Prediction of Reinforcement Effect by Screw on Triangular Embedment Perpendicular to the Grain with Variation of Screw Locations

Prediction of Reinforcement Effect by Screw on Triangular Embedment Perpendicular to the Grain with Variation of Screw Locations Open Journal of Civil Engineering,,, 67-73 http://dx.doi.org/.436/ojce..3 Published Online September (http://www.scirp.org/journal/ojce) of Reinforcement Effect by Screw on Triangular Embedment Perpendicular

More information

LOAD CARRYING CAPACITY OF METAL DOWEL TYPE CONNECTIONS OF TIMBER STRUCTURES

LOAD CARRYING CAPACITY OF METAL DOWEL TYPE CONNECTIONS OF TIMBER STRUCTURES Vol. 10, Issue /014, 51-60 DOI: 10.478/cee-014-0011 LOAD CARRYING CAPACITY OF METAL DOWEL TYPE CONNECTIONS OF TIMBER STRUCTURES Jozef GOCÁL 1,* 1 Department of Structures and Bridges, Faculty of Civil

More information

INTERNATIONAL COUNCIL FOR BUILDING RESEARCH STUDIES AND DOCUMENTATION WORKING COMMISSION W18- TIMBER STRUCTURES

INTERNATIONAL COUNCIL FOR BUILDING RESEARCH STUDIES AND DOCUMENTATION WORKING COMMISSION W18- TIMBER STRUCTURES CIB-W18/25-7-11 INTERNATIONAL COUNCIL FOR BUILDING RESEARCH STUDIES AND DOCUMENTATION WORKING COMMISSION W18- TIMBER STRUCTURES MULTIPLE-FASTENER DOWEL-TYPE JOINTS, A SELECTED REVIEW OF RESEARCH AND CODES

More information

American Institute of Timber Construction 7012 South Revere Parkway Suite 140 Centennial, CO Phone: 303/ Fax: 303/

American Institute of Timber Construction 7012 South Revere Parkway Suite 140 Centennial, CO Phone: 303/ Fax: 303/ American Institute of Timber Construction 7012 South Revere Parkway Suite 140 Centennial, CO 80112 Phone: 303/792-9559 Fax: 303/792-0669 404.1. SCOPE STANDARD FOR RADIALLY REINFORCING CURVED GLUED LAMINATED

More information

Cyclic tests of engineered shear walls with different bottom plate and anchor bolt washer sizes (Phase II)

Cyclic tests of engineered shear walls with different bottom plate and anchor bolt washer sizes (Phase II) Cyclic tests of engineered shear walls with different bottom plate and anchor bolt washer sizes (Phase II) Prepared by Rakesh Gupta, Associate Professor Heather Redler, Graduate Research Assistant Milo

More information

Renewed use of wood in commercial construction. Learning Objectives

Renewed use of wood in commercial construction. Learning Objectives CONNECTION SOLUTIONS IN MODERN TIMBER STRUCTURES Long Beach Wood Solutions Fair March 02, 2011 The Wood Products Council is a Registered Provider with The American Institute of Architects Continuing Education

More information

Sturdi-Wall Design Manual for SW46, SW66, SW63, SW64, SW60, SW83, SW84, and SW80 Models

Sturdi-Wall Design Manual for SW46, SW66, SW63, SW64, SW60, SW83, SW84, and SW80 Models Sturdi-Wall Design Manual for SW46, SW66, SW63, SW64, SW60, SW83, SW84, and SW80 Models Project Number ME086-05 by Brent Leatherman, P.E. Timber Tech Engineering, Inc E-Mail: bl@timbertecheng.com January

More information

APA Report T Shear Wall Lumber Framing: Double 2x s vs. Single 3x s at Adjoining Panel Edges APA - The Engineered Wood Association

APA Report T Shear Wall Lumber Framing: Double 2x s vs. Single 3x s at Adjoining Panel Edges APA - The Engineered Wood Association A P A The Engineered Wood Association APA Report T23-22 Shear Wall Lumber Framing: Double 2x s vs. Single 3x s at Adjoining Panel Edges By Zeno A. Martin, P.E. and Thomas D. Skaggs, Ph.D., P.E. Technical

More information

Changes in the 2001 NDS for Wood Construction

Changes in the 2001 NDS for Wood Construction Changes in the 2001 NDS for Wood Construction Philip Line, P.E.; Dr. Robert Taylor, P.Eng.; John Buddy Showalter, P.E.; Bradford K. Douglas, P.E. Introduction The 2001 Edition of the National Design Specification

More information

ICC-ES Evaluation Report Reissued June 1, 2010 This report is subject to re-examination in one year.

ICC-ES Evaluation Report Reissued June 1, 2010 This report is subject to re-examination in one year. ICC-ES Evaluation Report ESR-2648 Reissued June 1, 2010 This report is subject to re-examination in one year. www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council

More information

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER: SCREW PRODUCTS, INC.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER: SCREW PRODUCTS, INC. 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3654 Reissued 09/2017 This report is subject to renewal 09/2018. DIVISION: 06 00

More information

Glulam Curved Members. Glulam Design. General Glulam Design. General Glulam Beams are Designed in the SAME Manner as Solid Sawn Beams

Glulam Curved Members. Glulam Design. General Glulam Design. General Glulam Beams are Designed in the SAME Manner as Solid Sawn Beams Glulam Curved Members Glulam Design General Glulam Beams are Designed in the SAME Manner as Solid Sawn Beams There is an Additional Adjustment Factor, C v, the Volume Factor C v and C L (Lateral Stability

More information

Experimental and numerical study of nailed laminated timber elements for in plane and transverse loading

Experimental and numerical study of nailed laminated timber elements for in plane and transverse loading Experimental and numerical study of nailed laminated timber elements for in plane and transverse loading Haller, Peer 1 SUMMARY Nailed laminated timber elements are used in housing construction for floor,

More information

STRUCTURAL ATTACHMENTS

STRUCTURAL ATTACHMENTS Brace Structural Attachment Selection Procedure ) Determine structure to be attached to from the following: A) Concrete B) Wood Beam C) Structural Steel 2) Reference structure connection type from Appendix

More information

Hazlan Abdul Hamid* & Mohammad Iqbal Shah Harsad

Hazlan Abdul Hamid* & Mohammad Iqbal Shah Harsad Malaysian Journal of Civil Engineering 28(1):59-68 (2016) BEHAVIOUR OF SELF-DRILLING SCREW UPON SINGLE SHEAR LOADING ON COLD FORMED STEEL Hazlan Abdul Hamid* & Mohammad Iqbal Shah Harsad Faculty of Civil

More information

Verbindungselemente Engel GmbH Weltestraße Weingarten DEUTSCHLAND. Manufacturing plant 74437, , ,

Verbindungselemente Engel GmbH Weltestraße Weingarten DEUTSCHLAND. Manufacturing plant 74437, , , European Technical Assessment ETA-13/0536 of 20 February 2018 - Original version in German language General Part Technical Assessment Body issuing the European Technical Assessment: Trade name of the construction

More information

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER: 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 42 687 (62) 699 04 www.icc es.org ESR 2442 Reissued 0/208 This report is subject to renewal 0/209. DIVISION: 06 00 00 WOOD,

More information

A STUDY ON PATTERN DAMAGE OF FINGER JOINTS IN BAMBOO LAMINATED BEAMS

A STUDY ON PATTERN DAMAGE OF FINGER JOINTS IN BAMBOO LAMINATED BEAMS A STUDY ON PATTERN DAMAGE OF FINGER JOINTS IN BAMBOO LAMINATED BEAMS Agus Rivani * * Abstract The aim of this study was to know the pattern damage of finger joints in bamboo laminated beams. The dimension

More information

CLT Connections Design Seminar on CLT Design, including Connections, and Resistance to Lateral and Gravity Loads

CLT Connections Design Seminar on CLT Design, including Connections, and Resistance to Lateral and Gravity Loads CLT Connections Design Seminar on CLT Design, including Connections, and Resistance to Lateral and Gravity Loads Moncton, NB December 1, 2015 Overview Why connections in CLT are different from other EWP

More information

EVALUATING BEARING PROPERTIES OF WOOD PEG CONNECTION USING FOUR DIFFERENT TEST METHODS. G. Y. Jeong* J. H. Kong

EVALUATING BEARING PROPERTIES OF WOOD PEG CONNECTION USING FOUR DIFFERENT TEST METHODS. G. Y. Jeong* J. H. Kong EVALUATING BEARING PROPERTIES OF WOOD PEG CONNECTION USING FOUR DIFFERENT TEST METHODS G. Y. Jeong* Associate Professor Department of Wood Science and Engineering Chonnam National University 77 Yongbongro

More information

Fire resistance tests on beam-to-column shear connections Pedro Palma, Andrea Frangi, Erich Hugi, Paulo Cachim and Helena Cruz

Fire resistance tests on beam-to-column shear connections Pedro Palma, Andrea Frangi, Erich Hugi, Paulo Cachim and Helena Cruz Research Collection Conference Paper Fire resistance tests on beam-to-column shear connections Pedro Palma, Andrea Frangi, Erich Hugi, Paulo Cachim and Helena Cruz Author(s): Frangi, Andrea; Palma, Pedro;

More information

Comparative Evaluation of Resistance Made Simple Shear Connection with Bolts and With Welding

Comparative Evaluation of Resistance Made Simple Shear Connection with Bolts and With Welding International Journal of Engineering Inventions e-issn: 78-7461, p-issn: 319-6491 Volume 3, Issue 7 (February 014) PP: 1-5 Comparative Evaluation of Resistance Made Simple Shear Connection with Bolts and

More information

1/2/2016. Lecture Slides. Screws, Fasteners, and the Design of Nonpermanent Joints. Reasons for Non-permanent Fasteners

1/2/2016. Lecture Slides. Screws, Fasteners, and the Design of Nonpermanent Joints. Reasons for Non-permanent Fasteners Lecture Slides Screws, Fasteners, and the Design of Nonpermanent Joints Reasons for Non-permanent Fasteners Field assembly Disassembly Maintenance Adjustment 1 Introduction There are two distinct uses

More information

Cast-in Ferrule Connections Load/Displacement Characteristics in Shear

Cast-in Ferrule Connections Load/Displacement Characteristics in Shear Cast-in Ferrule Connections Load/Displacement Characteristics in Shear Ian Ferrier 1 and Andrew Barraclough 2 1 Product Manager - Connections, ITW Construction Systems ANZ. 2 Research and Development Manager,

More information

Development of Wooden Portal Frame Structures with Improved Columns

Development of Wooden Portal Frame Structures with Improved Columns Development of Wooden Portal Frame Structures with Improved Columns by Dr. Masahiro Noguchi Post Doctoral Fellow Tokyo Institute of Technology, Yokohama, Kanagawa, Japan Prof. dr. Kohei Komatsu Professor

More information

M. Bücker*, M. Magin. Institute for Composite Materials, Erwin-Schrödinger-Straße 58, Kaiserslautern, Germany

M. Bücker*, M. Magin. Institute for Composite Materials, Erwin-Schrödinger-Straße 58, Kaiserslautern, Germany TESTING OF THE STRENGTH OF AN ALTERNATIVE MANUFACTURING METHOD FOR BOLTED JOINTS USED IN A GFRP-ROTOR OF AN AXIAL-FLUX ELEKTRIC MOTOR FOR SERIAL PRODUCTION IN AUTOMOTIVE M. Bücker*, M. Magin Institute

More information