DETECTION OF FAULT IN PWM VOLTAGE SOURCE INVERTER FOR PMSM DRIVE SYSTEM

Size: px
Start display at page:

Download "DETECTION OF FAULT IN PWM VOLTAGE SOURCE INVERTER FOR PMSM DRIVE SYSTEM"

Transcription

1 DETECTION OF FAULT IN PWM VOLTAGE SOURCE INVERTER FOR PMSM DRIVE SYSTEM 1 ANUTTAR J. SHENDE, 2 S.D.JOSHI 1,2 Dept. of Electrical Engineering P.E.S. Modern College of Engineering, Pune, Maharashtra, India 1 anuttar.shende@gmail.com Abstract In this paper, a easy and low-cost fault identification and detection method for (PWM) pulse-width modulated and voltage-source inverter (VSI) for (PMSM) drive system is proposed. Fault in a power switch of PWM VSI varies the respective terminal voltages and causes the voltage distortions in each phase voltage. The proposed fault diagnosis method employs the (MRAS) model reference adaptive system techniques and needs no additional sensors or electrical devices to identify the fault situation and detect the faulty switch. The proposed technique has the features of fast identification time, easy structure, and being easily introduced to the existing control algorithms as a sub-routine without any major modifications. The experiments and MATLAB simulations are being carried out and the results show the effectiveness of the proposed method. Index Terms Fault Detection, Fault Diagnosis, Fault Identification, Pulse-Width Modulated Voltage-Source Inverter (PWM VSI). I. INTRODUCTION The (PMSM) permanent magnet synchronous motor is increasingly used in electrically powered wheelchairs, electric vehicles, military and medical applications, aerospace and nuclear power plants due to its advantages such as torque to inertia ratio, high power density, simple control and efficiency [3]. In these applications, due to any accident or fault can result in huge damages to the environments and human life, reliability of the machine drives is one of the most important factors to guarantee the safety of personals, continuous and high performance operation under even some accidents or faulty condition. Generally, when an accident or fault occurs, the drive system has to be stopped for non programmed maintenance schedule or emergency. Due to the high cost of unexpected maintenance, the development of a reliable system is the area of interest. The control system with less or zero effects from the faults is called a fault-tolerant controlsystem and it employs the following three tasks [11]: 1) Fault detection; 2) Fault identification; 3) Remedial actions. The fault detection is the method to check whether the system is healthy or not. The fault identification is performed after fault detection process, to identify the fault location, its type, and nature of the fault. Finally, the remedial action, also known as fault isolation, is the process to remove the faulty devices and reconfigure the system for a safe and continuous operation. Out of these three methods, the fault detection and fault identification are considered as an important process for the practical implementation and are often called as a fault diagnosis. [2]. Typically the motor drive systems consist of a power electronic converter, i.e., pulse-width modulated voltage source inverter (PWM VSI), and a motor. 1) Motor (PMSM) 2) Power converter (PWM VSI) 3) Connectors and wire 4) Sensors The connectors, and wires have very low failure rates compared to the remaining of the system. The connectors and wires are static and have low failure rates if selected and installed properly. Some of the machine faults caused by the winding insulation failure due to the excessive voltage or current stress can practically be removed because the line voltage surges are absorbed at the input side of the power converter and the current stresses are limited by the over current protection of the power converter [4]. In recent years, the sensor faults have been increasingly concerned in the literature works. The sensor faults including biased signal, loss of signal, incorrect gain, and unresponsive signal are mainly due to the broken or bad connections, bad communications, or some hardware or software malfunction. Therefore, if the connectors and wires are installed correctly, the failure rates of the sensor faults can be lowered. For these reasons, those faults are not considered.[12] - [13]. The statistical studies are introduced to show the components most susceptible to failures. These studies show that about 38% of failures in variable speed AC drives in industry are mostly found in power equipment and 53% in control circuits [17]. Also an industry based survey regarding the reliability in power electronic converters show that power devices, gate control circuits and capacitors are the most susceptible components [18]. Recently, another study shows that soldering, semiconductor and printed circuit board failures in the device modules totals about 60% of converter system failures [19]. Therefore, it is possible to conclude that a very high percentage of failures are reflected on power switch faults, since a failure in a gate control 111

2 circuit which results open-circuit fault in a switch. [20]. Power switch failures can be largely distributed as open circuit faults and short-circuit faults. Inverter typical protection methods include protection against the over-current or short-circuit, but they do not guarantee the protection against the open-circuit faults. Then, open-circuit faults can remain hidden or undetected for an extended period of time, tending to potential secondary faults in the converter. [1]. On the other hand, the power converter failures can be a critical factor to the overall system causing shutdowns; therefore, these require a high cost of unexpected maintenance. It is estimated that about 38% of all the failures are found in the power converter [14] and the most of faults are occurred to the power switches [15]. A voltage command is generated in response to a control algorithm and the VSI synthesizes this voltage command using the power switches, i.e., insulated-gate bipolar transistor (IGBT) and MOSFET, with the techniques such as the sinusoidal PWM or space vector. There could be a quite high chance of failure in the switching devices due to the high electrical and thermal stresses [16]. The failure of switching devices can take place in the form of open circuit or short circuit. An improper gate signal causes the short circuit fault so that both power switches in a leg of the VSI are turned ON. This results in the short circuit of the capacitor in the dc link that blows out the other components particularly switching devices. Therefore, the shortcircuit fault is one of the most severe accidents and the most important thing in the drive system, is to minimize the time between appropriate reaction and short-circuit fault initiation. Apparently, the control circuits are build so that a fast fault diagnosis characteristic to prevent the abnormal overcurrent and mostly the hardware based protection schemes are introduced. On the other hand the open-circuit fault, is often considered since it has the characteristic of less danger and slow response to the whole drive system compared with the short-circuit fault. The open-circuit fault maybe due to from the disconnection of a wire from the switching devices results to gate driver failure or thermic cycling. The opencircuit fault leads to the current imbalance in both the healthy and faulty phases results in the pulsating currents and torques, which highly degrades the driving performances. The opencircuit fault does not results system shutdowns and is not generally harmful to the machine drives and, but could lead to the secondary faults at the other components [4]. II BLOCK DIAGRAM AND ITS DESCRIPTION The block diagram of open circuit fault detection in PWM voltage source inverter for SM drive system is shown in fig 3.1 Fig 3.1: Block diagram of open circuit fault detection in PWM voltage source inverter for PMSM drive system It consist of: 1. Pulse generator- It is used to generate the PWM signals which is given to the gate terminal of MOSFET. 2. Inverter- It is used to convert DC into AC. This AC is then given to the motor via filter. 3. Filter- It is used to convert PWM pulses into sinusoidal wave. It is also used to remove the remaining distortion from the system. 4. Scope 1- It is used to see the results of inverter output in terms of voltage in normal condition as well in faulty condition. 5. Motor- Permanent magnet synchronous motor is used in this project. 6. Scope 3- It is used to see the results of in terms of voltage, current, speed and torque.in normal condition as well as in faulty condition. 7. Statcom- It is used to reduce the distortions to some extent of the faulty phase after the fault occurs. 8. Scope 2- It is used to see the results of STATCOM in terms of voltage in normal condition as well as in faulty condition. III. ANALYSIS OF THE OPEN-CIRCUIT FAULT IN THE PWM VSI Fig.2 shows the basic configuration of phase A leg of a three phase PWM System. When the system is under the normal condition as can be seen in Fig. 2(a), the terminal voltage of phase A, is determined by the phase current ias and the switching function Sa of QaU and QaL. If the switching function is 1, which means that when, QaU is turned ON and QaL is turned OFF, the terminal voltage of phase A is equal to half of Vdc, where Vdc is the DC voltage. If the switching function is 0, which means that QaU is turned OFF and QaL is ON, va0 = Vdc divided by 2. The possible terminal voltages according to the 112

3 switching function and the direction of phase current under the normal condition are Fig. 2. Basic configuration of phase A leg of a three-phase PWM VSI. (a) Normal system. (b) Open-circuit fault in the top switch QaU. Represented in TableI. Unlike the normal condition, an opencircuit fault in the top switch QaU results in changing the corresponding terminal voltage when the phase current ias is positive and the switching function Sa is 1, since the top switch QaU is not working properly. So that, the terminal voltage of phase A is not equal to Vdc/2,but equal to Vdc/2.The equivalent circuit after the open-circuit fault occurrence to the top switch QaU is shown in Fig. 2(b), and the corresponding terminal voltages are represented in Table II. TABLE I TERMINAL VOLTAGES OF PHASE AUNDER THE NORMAL CONDITION From the aforementioned analysis, it is observed that the phase voltages may have the voltage deviations in the steady state after the fault detected from the normal condition. Based on this fact, the proposed fault diagnosis method indirectly observes these voltage deviations using the analytical model of the PWM VSI and the fault diagnosis can be achieved. IV. SIMULATION MODEL The working of the experimental model is as follows: 1. Mainly the circuit consist of an inverter which consist of 6 MOSFETs. We can use any switch instead of MOSFET like BJT, IGBT, GTO, etc. We are using MOSFET because it is cheap as compared to other switches. 2. The PWM generator is used to give the PWM pulses to the gate terminal of MOSFET. MOSFET and internal diode in parallel with a series RC snubber circuit. When a gate signal is applied the MOSFET conducts and acts as a resistance (Ron) in both directions. If the gate signal falls to zero when current is negative, current is transferred to the antiparallel diode. 3. The inverter is basically used to convert DC into AC. The input of inverter is 440V dc and output is fed to the PMSM through LC filter. 113

4 We can change the magnitude of input dc voltage, by changing the magnitude of dc voltage, only the amplitude of the output gets changed. 4. LC filter is used to remove the remaining distortions from the inverter system. 5. The output which comes from inverter can be checked in scope 1. For this, three voltage measurement blocks are connected to the scope Here, three phase PMSM machine with sinusoidal back EMF or trapezoidal back EMF is used. Sinusoidal machine is modeled in dq rotor reference and trapezoidal machine is modeled in abc reference frame. Here we use sinusoidal back EMF. Stator windings are connected in wye to an internal neutral point. The parameters of the motor can be observed by referring the model. The mechanical input to the PMSM is mechanical torque. We can either use constant torque or step torque. Step torque is used to get the result in step form. Normally we used constant mechanical torque. The scope is attached to the motor which is used to see the result of the changes in voltage, current, torque and speed of the motor. There is a voltage measurement block attached to the scope to measure the voltage, Goto blocks which are used to send the signals to from blocks that have specified tag. If tag visibility in scoped then Goto tag visibility block must be used to define visibility of tag. Block icon displays the selected tag name. Before current Goto block there is sample and hold with one sample period delay. 7. Here extra block of three phase short circuit fault is used. We can use this block to program a short circuit fault between any phase to ground. 8. STATCOM is used only to reduce the distortions to some extent in particular phase after fault occurs. Scope 2 is used to see the results after applying the STATCOM. V. SIMULATION RESULTS Table 4.1 Different results of MATLAB model We can make the open circuit connection in two ways. Either we can remove the phases by opening the switches which are connected to gate terminal of MOSFET or we can open the phase connection with the help of three phase short circuit fault. The results which we get by opening the phases through switches and by opening the phases using short circuit fault are totally different. It is because open circuit fault using switches represent the fault to the inut of the inverter and open circuit fault using three phase short circuit fault to the output of the inverter. The following table shows different results related to this project which is as follows: The following waveform shows results for different cases: 114

5 1. Under normal condition 3. When phase B open by opening S3, S4 Fig.4.2 Three phase output of the inverter in normal condition. Fig.4.7 voltage waveform when phase B open circuited by removing switches S3, S4. Fig. 4.3 PMSM machine characteristics in terms of voltage, current, speed and torque in normal condition. 2. When phase A open circuited by opening S1, S2 Fig 4.8. Changes in motor current, voltage, speed and torque when phase B is Open Circuit fault by removing switches S3, S4 Fig.4.4 voltage waveform when phase A open circuited by removing switches S1, S2. Fig. 4.9 voltage waveform of statcom after phase B open by removing switches S3, S4. CONCLUSION Fig 4.5. Changes in motor current, voltage, speed and torque when phase A is Open Circuit fault by removing switches S1, S2. Fig. 4.6 voltage waveform of statcom after phase A open by removing switches S1, S2 The fault detection and identification is becoming moreand more important for industrial applications. Therefore, it is increasingly required to improve the fault diagnosis capabilities. In this project, a simple and low-cost open-circuit fault detection and identification method is presented. The proposed method can be well combined with the post fault actions which are the reconfigurations of the whole drive system to operate safely and continuously. In comparison with the previous existing fault diagnosis, the proposed method has simple structure and fast fault detection time. Also, it can be implemented without any extra devices such as voltage sensors and the computing effort is very small. The execution of the algorithm can be easily embedded in the existing systems without major modifications. To show the effectiveness of the proposed method, the simulations and experiments are carried out for the PMSM drive system. The simulation and experimental results 115

6 verify the validity of the proposed method and show that the proposed method gives the good performance and practical value. REFERENCES [1] Arafa S. Mohamed, Haitham Z. Azazy and Ashraf S. Zein El Din, Open-Circuit Fault Diagnosis Of Three-Phase Induction Motor Drive Systems, Journal of Electrical Engineering. [2] Shin-Myung Jung, Jin-Sik Park, Hag-Wone Kim, Kwan- Yuhl Cho, and Myung-Joong Youn, An MRAS-Based Diagnosis of Open Circuit Fault in PWM Voltage-Source Inverters for PM Synchronous Motor Drive Systems IEEE Transactions On Power Electronics, Vol. 28, No. 5, May 2013 [3] P. C. Krause, O. Wasynczuk, and S. D. Sudhoff, Analysis of Electric Machinery, IEEE Press: IEEE Power Eng. Soc., [4] D. Kastha and B. K. Bose, Investigation of fault modes of voltage-fed inverter system for induction motor drive, IEEE Trans. Ind. Appl., vol. 30, no. 4, pp , Jul./Aug [5] M.R. Ubale, R. B. Dhumale, S. D. Lokhande, Open switch fault diagnosis in three phase inverter using diagnostic variable method, IEEE Trans. Power Electron., vol no. 2, pp , Dec [6] Byoung-Kuk Lee. On the Feasibility of Four-Switch Three-Phase BLDC Motor Drives for Low Cost Commercial Applications: Topology and Control, IEEE Trans. On power electronics, vol. 18, no. 1, pp , Jan [7] Jorge O. Estima and Antonio J. Marques Cardoso, A New Approach for Real-Time Multiple Open-Circuit Fault Diagnosis in Voltage-Source Inverters, IEEE Trans. On Industry Application, vol. 47, no. 6, pp , Nov/Dec [8] M.D. Singh and K.B. Khanchandani power Electronics Second Edition, McGraw Hill Publication, pp 535 to 593. [9] B.L. Theraja and A. K. -Theraja AC and DC machine, S. Chand Publication vol.2, pp-1489,1551. [10] static-synchronous-compensator.html [11] R. L. A. Ribeiro, C. B. Jacobina, E. R. C. Silva, anda. M. N. Lima, Fault detection of open-switch damage in voltagefed PWM motor drive systems, IEEE Trans. Power Electron., vol. 18, no. 2, pp , Mar [12] P. A. Samara, G. N. Fouskitakis, J. S. Sakellariou, and S. D. Fassois, A statistical method for the detection of sensor abrupt faults in aircraft control systems, IEEE Trans. Ind. Control Syst. Technol., vol. 16, no. 4, pp , Jul [13] H. Berriri, M. W. Naouar, and I. Slama-Belkhodja, Easy and fast sensor fault detection and isolation algorithm for electrical drives, IEEE Trans. Power Electron., vol. 27, no. 2, pp , Feb [14] O. V. Thorsen and M. Dalva, A survey of the reliability with an analysis of faults on the variable frequency drives in industry, in Proc. Conf. Rec. 6th Eur. Power Electron. Appl. Conf., Sevilla, Spain, 1995, pp [15] H. Schwab, A. Klonne, S. Reck, and I. Ramesohl, Reliability evaluation of a permanent magnet synchronous motor drive for an automotive application, in Proc. Conf. Rec. 10th Eur. Power Electron. Appl. Conf., Toulouse, France, 2003, ISBN: [16] F. W. Fuchs, Some diagnosis methods for voltage source inverters in variable speed drives with induction machines A survey, in Proc. IEEE Ind. Electron. Conf., Nov. 2003, pp [17] Sethom, H.A. Ghedamsi, M.A.: Intermittent misfiring default detection and localisation on a PWM inverter using wavelet decomposition. In: Journal of Electrical Systems, Vol. 4, No. 2, 2008, p [18] Yang, S. at al.: An industry-based survey of reliability in power electronic converters. In: IEEE Transactions on Industry Applications, Vol. 47, No. 3, May/June 2011, p [19] Yang, S. at al.: Condition monitoring for device reliability in power electronic converters A review. In: IEEE Transactions on Power Electronics, Vol. 25, No. 11, November 2010, p [20] Freire N.A. Estima J.O., Marques Cardoso A.J.: Multiple open-circuit fault diagnosis in voltage-fed PWM motor drives using the current park's vector phase and the currents polarity. In: 8th IEEE International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives, September 2011, Bologna, Italy, p

Open circuit fault detection in PWM voltage source inverter for PMSM drive system

Open circuit fault detection in PWM voltage source inverter for PMSM drive system Open circuit fault detection in PWM voltage source inverter for PMSM drive system Anuttar J. Shende Department of Electrical Engineering, PESMCOE, Pune, Maharashtra, India -----------------------------------------------------------------------***--------------------------------------------------------------------

More information

Comparison of Different Modulation Strategies Applied to PMSM Drives Under Inverter Fault Conditions

Comparison of Different Modulation Strategies Applied to PMSM Drives Under Inverter Fault Conditions Comparison of Different Modulation Strategies Applied to PMSM Drives Under Inverter Fault Conditions Jorge O. Estima and A.J. Marques Cardoso University of Coimbra, FCTUC/IT, Department of Electrical and

More information

FAULT DETECTION AND DIAGNOSIS OF HIGH SPEED SWITCHING DEVICES IN POWER INVERTER

FAULT DETECTION AND DIAGNOSIS OF HIGH SPEED SWITCHING DEVICES IN POWER INVERTER FAULT DETECTION AND DIAGNOSIS OF HIGH SPEED SWITCHING DEVICES IN POWER INVERTER R. B. Dhumale 1, S. D. Lokhande 2, N. D. Thombare 3, M. P. Ghatule 4 1 Department of Electronics and Telecommunication Engineering,

More information

by a reference vector which rotates at an angular speed of ω.

by a reference vector which rotates at an angular speed of ω. Research Paper CLOSED LOOP OPERATION OF SVPWM BASED FOUR LEG FAULT TOLERANT INVERTER FOR INDUSTRIAL APPLICATIONS Dr. S. Nagarajan 1*, P.Saradha Devi 2 Address for Correspondence Department of Electrical

More information

Fuzzy-Logic-Controller-Based Fault Isolation in PWM VSI for Vector Controlled Induction Motor Drives

Fuzzy-Logic-Controller-Based Fault Isolation in PWM VSI for Vector Controlled Induction Motor Drives IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-issn: 2278-1676,p-ISSN: 2320-3331, Volume 10, Issue 6 Ver. II (Nov Dec. 2015), PP 07-15 www.iosrjournals.org Fuzzy-Logic-Controller-Based

More information

Reduction of Torque Ripple in Trapezoidal PMSM using Multilevel Inverter

Reduction of Torque Ripple in Trapezoidal PMSM using Multilevel Inverter Reduction of Torque Ripple in Trapezoidal PMSM using Multilevel Inverter R.Ravichandran 1, S.Sivaranjani 2 P.G Student [PSE], Dept. of EEE, V.S.B. Engineering College, Karur, Tamilnadu, India 1 Assistant

More information

On-Line Dead-Time Compensation Method Based on Time Delay Control

On-Line Dead-Time Compensation Method Based on Time Delay Control IEEE TRANSACTIONS ON CONTROL SYSTEMS TECHNOLOGY, VOL. 11, NO. 2, MARCH 2003 279 On-Line Dead-Time Compensation Method Based on Time Delay Control Hyun-Soo Kim, Kyeong-Hwa Kim, and Myung-Joong Youn Abstract

More information

A NOVEL SWITCHING PATTERN OF CASCADED MULTILEVEL INVERTERS FED BLDC DRIVE USING DIFFERENT MODULATION SCHEMES

A NOVEL SWITCHING PATTERN OF CASCADED MULTILEVEL INVERTERS FED BLDC DRIVE USING DIFFERENT MODULATION SCHEMES International Journal of Electrical and Electronics Engineering Research (IJEEER) ISSN(P): 2250-155X; ISSN(E): 2278-943X Vol. 3, Issue 5, Dec 2013, 243-252 TJPRC Pvt. Ltd. A NOVEL SWITCHING PATTERN OF

More information

Simulation Analysis of Three Phase & Line to Ground Fault of Induction Motor Using FFT

Simulation Analysis of Three Phase & Line to Ground Fault of Induction Motor Using FFT www.ijird.com June, 4 Vol 3 Issue 6 ISSN 78 (Online) Simulation Analysis of Three Phase & Line to Ground Fault of Induction Motor Using FFT Anant G. Kulkarni Research scholar, Dr. C. V. Raman University,

More information

PERMANENT magnet brushless DC motors have been

PERMANENT magnet brushless DC motors have been Inverter Switch Fault Diagnosis System for BLDC Motor Drives A. Tashakori and M. Ektesabi Abstract Safe operation of electric motor drives is of prime research interest in various industrial applications.

More information

Journal of Engineering Technology

Journal of Engineering Technology A novel mitigation algorithm for switch open-fault in parallel inverter topology fed induction motor drive M. Dilip *a, S. F. Kodad *b B. Sarvesh *c a Department of Electrical and Electronics Engineering,

More information

Simulation of Three Phase Cascaded H Bridge Inverter for Power Conditioning Using Solar Photovoltaic System

Simulation of Three Phase Cascaded H Bridge Inverter for Power Conditioning Using Solar Photovoltaic System Simulation of Three Phase Cascaded H Bridge Inverter for Power Conditioning Using Solar Photovoltaic System 1 G.Balasundaram, 2 Dr.S.Arumugam, 3 C.Dinakaran 1 Research Scholar - Department of EEE, St.

More information

Performance Enhancement of Sensorless Control of Z-Source Inverter Fed BLDC Motor

Performance Enhancement of Sensorless Control of Z-Source Inverter Fed BLDC Motor IJSTE - International Journal of Science Technology & Engineering Volume 1 Issue 11 May 2015 ISSN (online): 2349-784X Performance Enhancement of Sensorless Control of Z-Source Inverter Fed BLDC Motor K.

More information

Simulation and Implementation of FPGA based three phase BLDC drive for Electric Vehicles

Simulation and Implementation of FPGA based three phase BLDC drive for Electric Vehicles Volume 118 No. 16 2018, 815-829 ISSN: 1311-8080 (printed version); ISSN: 1314-3395 (on-line version) url: http://www.ijpam.eu ijpam.eu Simulation and Implementation of FPGA based three phase BLDC drive

More information

A Novel Cascaded Multilevel Inverter Using A Single DC Source

A Novel Cascaded Multilevel Inverter Using A Single DC Source A Novel Cascaded Multilevel Inverter Using A Single DC Source Nimmy Charles 1, Femy P.H 2 P.G. Student, Department of EEE, KMEA Engineering College, Cochin, Kerala, India 1 Associate Professor, Department

More information

Analysis of Voltage Source Inverters using Space Vector PWM for Induction Motor Drive

Analysis of Voltage Source Inverters using Space Vector PWM for Induction Motor Drive IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) ISSN: 2278-1676 Volume 2, Issue 6 (Sep-Oct. 2012), PP 14-19 Analysis of Voltage Source Inverters using Space Vector PWM for Induction

More information

Study on a Simplified Converter Topology for Fault Tolerant Motor Drives

Study on a Simplified Converter Topology for Fault Tolerant Motor Drives Study on a Simplified Converter Topology for Fault Tolerant Motor Drives L. Szabó, M. Ruba and D. Fodorean Technical University of Cluj, Department of Electrical Machines, Cluj, Romania Abstract Some of

More information

Modeling and Simulation of Induction Motor Drive with Space Vector Control

Modeling and Simulation of Induction Motor Drive with Space Vector Control Australian Journal of Basic and Applied Sciences, 5(9): 2210-2216, 2011 ISSN 1991-8178 Modeling and Simulation of Induction Motor Drive with Space Vector Control M. SajediHir, Y. Hoseynpoor, P. MosadeghArdabili,

More information

Sensorless control of BLDC motor based on Hysteresis comparator with PI control for speed regulation

Sensorless control of BLDC motor based on Hysteresis comparator with PI control for speed regulation Sensorless control of BLDC motor based on Hysteresis comparator with PI control for speed regulation Thirumoni.T 1,Femi.R 2 PG Student 1, Assistant Professor 2, Department of Electrical and Electronics

More information

Inductor Current Based Fault Diagnostic System for Four Port DC/DC Converter

Inductor Current Based Fault Diagnostic System for Four Port DC/DC Converter Inductor Current Based Fault Diagnostic System for Four Port DC/DC Converter T. K. Santhosh 1, C. Govindaraju 2 1 Ph.D. Scholar, 2 Assistant Professor Department of Electrical & Electronics Engineering,

More information

Diagnostics. Lesson 3. Ewen Ritchie Krisztina Leban

Diagnostics. Lesson 3. Ewen Ritchie Krisztina Leban Diagnostics Lesson 3 Ewen Ritchie Krisztina Leban 1 1. Converter faults - General 2. PMSM + Inverter 3. IM + Inverter 4. DFIG + Inverter 6. Hybrid EV + Matrix converter 8. Monitoring - SCADA 5. References

More information

Economic Single-Phase to Three-Phase Converter for Low Power Motor Drives

Economic Single-Phase to Three-Phase Converter for Low Power Motor Drives Economic Single-Phase to Three-Phase Converter for Low Power Motor Drives Nidhin Jose B.Tech Student, Electrical and Electronics Engineering Dept., A P J Abdul Kalam Technological University, Kerala, India

More information

Reduction of Harmonics and Torque Ripples of BLDC Motor by Cascaded H-Bridge Multi Level Inverter Using Current and Speed Control Techniques

Reduction of Harmonics and Torque Ripples of BLDC Motor by Cascaded H-Bridge Multi Level Inverter Using Current and Speed Control Techniques Reduction of Harmonics and Torque Ripples of BLDC Motor by Cascaded H-Bridge Multi Level Inverter Using Current and Speed Control Techniques A. Sneha M.Tech. Student Scholar Department of Electrical &

More information

Speed control of Induction Motor drive using five level Multilevel inverter

Speed control of Induction Motor drive using five level Multilevel inverter Speed control of Induction Motor drive using five level Multilevel inverter Siddayya hiremath 1, Dr. Basavaraj Amarapur 2 [1,2] Dept of Electrical & Electronics Engg,Poojya Doddappa Appa college of Engg,

More information

A Novel Three-Phase to Nine-Phase Transformation using a Special Transformer Connection

A Novel Three-Phase to Nine-Phase Transformation using a Special Transformer Connection A Novel Three-Phase to Nine-Phase Transformation using a Special Transformer Connection Mohd Rizwan Khalid Research Scholar, Electrical Engineering Dept, Zakir Husain College of Engineering and Technology,

More information

Modeling and Simulation of Five Phase Induction Motor Fed with Five Phase Inverter Topologies

Modeling and Simulation of Five Phase Induction Motor Fed with Five Phase Inverter Topologies Indian Journal of Science and Technology, Vol 8(19), DOI: 1.17485/ijst/215/v8i19/7129, August 215 ISSN (Print) : 974-6846 ISSN (Online) : 974-5645 Modeling and Simulation of Five Phase Induction Motor

More information

Modeling and Simulation Analysis of Eleven Phase Brushless DC Motor

Modeling and Simulation Analysis of Eleven Phase Brushless DC Motor Modeling and Simulation Analysis of Eleven Phase Brushless DC Motor Priyanka C P 1,Sija Gopinathan 2, Anish Gopinath 3 M. Tech Student, Department of EEE, Mar Athanasius College of Engineering, Kothamangalam,

More information

Simulation of Speed Control of Induction Motor with DTC Scheme Patel Divyaben Lalitbhai 1 Prof. C. A. Patel 2 Mr. B. R. Nanecha 3

Simulation of Speed Control of Induction Motor with DTC Scheme Patel Divyaben Lalitbhai 1 Prof. C. A. Patel 2 Mr. B. R. Nanecha 3 IJSRD - International Journal for Scientific Research & Development Vol. 3, Issue 09, 2015 ISSN (online): 2321-0613 Simulation of Speed Control of Induction Motor with DTC Scheme Patel Divyaben Lalitbhai

More information

Enhanced Performance of Multilevel Inverter Fed Induction Motor Drive

Enhanced Performance of Multilevel Inverter Fed Induction Motor Drive Enhanced Performance of Multilevel Inverter Fed Induction Motor Drive Venkata Anil Babu Polisetty 1, B.R.Narendra 2 PG Student [PE], Dept. of EEE, DVR. & Dr.H.S.MIC College of Technology, AP, India 1 Associate

More information

International Research Journal of Engineering and Technology (IRJET) e-issn: Volume: 03 Issue: 11 Nov p-issn:

International Research Journal of Engineering and Technology (IRJET) e-issn: Volume: 03 Issue: 11 Nov p-issn: THD COMPARISON OF F1 AND F2 FAILURES OF MLI USING AMPLITUDE LIMITED MODULATION TECHNIQUE S.Santhalakshmy 1, V.Thebinaa 2, D.Muruganandhan 3 1Assisstant professor, Department of Electrical and Electronics

More information

MODELLING AND SIMULATION OF DIODE CLAMP MULTILEVEL INVERTER FED THREE PHASE INDUCTION MOTOR FOR CMV ANALYSIS USING FILTER

MODELLING AND SIMULATION OF DIODE CLAMP MULTILEVEL INVERTER FED THREE PHASE INDUCTION MOTOR FOR CMV ANALYSIS USING FILTER MODELLING AND SIMULATION OF DIODE CLAMP MULTILEVEL INVERTER FED THREE PHASE INDUCTION MOTOR FOR CMV ANALYSIS USING FILTER Akash A. Chandekar 1, R.K.Dhatrak 2 Dr.Z.J..Khan 3 M.Tech Student, Department of

More information

Digital PWM Techniques and Commutation for Brushless DC Motor Control Applications: Review

Digital PWM Techniques and Commutation for Brushless DC Motor Control Applications: Review Digital PWM Techniques and Commutation for Brushless DC Motor Control Applications: Review Prof. S.L. Tade 1, Ravindra Sor 2 & S.V. Kinkar 3 Professor, Dept. of E&TC, PCCOE, Pune, India 1 Scientist, ARDE-DRDO,

More information

Reduction of Power Electronic Devices with a New Basic Unit for a Cascaded Multilevel Inverter fed Induction Motor

Reduction of Power Electronic Devices with a New Basic Unit for a Cascaded Multilevel Inverter fed Induction Motor International Journal for Modern Trends in Science and Technology Volume: 03, Issue No: 05, May 2017 ISSN: 2455-3778 http://www.ijmtst.com Reduction of Power Electronic Devices with a New Basic Unit for

More information

ANALYSIS OF POWER QUALITY IMPROVEMENT OF BLDC MOTOR DRIVE USING CUK CONVERTER OPERATING IN DISCONTINUOUS CONDUCTION MODE

ANALYSIS OF POWER QUALITY IMPROVEMENT OF BLDC MOTOR DRIVE USING CUK CONVERTER OPERATING IN DISCONTINUOUS CONDUCTION MODE ANALYSIS OF POWER QUALITY IMPROVEMENT OF BLDC MOTOR DRIVE USING CUK CONVERTER OPERATING IN DISCONTINUOUS CONDUCTION MODE Bhushan P. Mokal 1, Dr. K. Vadirajacharya 2 1,2 Department of Electrical Engineering,Dr.

More information

Swinburne Research Bank

Swinburne Research Bank Swinburne Research Bank http://researchbank.swinburne.edu.au Tashakori, A., & Ektesabi, M. (2013). A simple fault tolerant control system for Hall Effect sensors failure of BLDC motor. Originally published

More information

Modeling and Analysis of Common-Mode Voltages Generated in Medium Voltage PWM-CSI Drives

Modeling and Analysis of Common-Mode Voltages Generated in Medium Voltage PWM-CSI Drives IEEE TRANSACTIONS ON POWER ELECTRONICS, VOL. 18, NO. 3, MAY 2003 873 Modeling and Analysis of Common-Mode Voltages Generated in Medium Voltage PWM-CSI Drives José Rodríguez, Senior Member, IEEE, Luis Morán,

More information

ADVANCED DC-DC CONVERTER CONTROLLED SPEED REGULATION OF INDUCTION MOTOR USING PI CONTROLLER

ADVANCED DC-DC CONVERTER CONTROLLED SPEED REGULATION OF INDUCTION MOTOR USING PI CONTROLLER Asian Journal of Electrical Sciences (AJES) Vol.2.No.1 2014 pp 16-21. available at: www.goniv.com Paper Received :08-03-2014 Paper Accepted:22-03-2013 Paper Reviewed by: 1. R. Venkatakrishnan 2. R. Marimuthu

More information

ABSTRACT. Introduction

ABSTRACT. Introduction Simulation Of A 4-Switch,3-Phase Inverter Fed Induction Motor (IM) Drive System Prof. A.A.Apte AISSMS College of Engineering, Pune University/Pune, Maharashtra, India V.D.Malwade AISSMS College of Engineering,

More information

Improved Power Quality Bridgeless Isolated Cuk Converter Fed BLDC Motor Drive

Improved Power Quality Bridgeless Isolated Cuk Converter Fed BLDC Motor Drive Improved Power Quality Bridgeless Isolated Cuk Converter Fed BLDC Motor Drive 1 Midhun Mathew John, 2 Phejil K Paul 1 PG Scholar, 2 Assistant Professor, 1 Electrical and Electronics Engineering 1 Mangalam

More information

ABSTRACT I. INTRODUCTION

ABSTRACT I. INTRODUCTION 2017 IJSRST Volume 3 Issue 8 Print ISSN: 2395-6011 Online ISSN: 2395-602X Themed Section: Science and Technology A Novel Zeta Converter with Pi Controller for Power Factor Correction in Induction Motor

More information

V. Naga Surekha 1, A. Krishna Teja 2, V. Mahesh 3, N. Sirisha 4

V. Naga Surekha 1, A. Krishna Teja 2, V. Mahesh 3, N. Sirisha 4 SequentialFive Leg Inverter for five phase supply V. Naga Surekha 1, A. Krishna Teja 2, V. Mahesh 3, N. Sirisha 4 1 (Student, Department of EEE, KLUniversity) 2 (Student, Department of EEE, K L University)

More information

Implementation of Resistor based Protection Scheme for the Fault Conditions and Closed Loop Operation of a Three-Level DC-DC Converter

Implementation of Resistor based Protection Scheme for the Fault Conditions and Closed Loop Operation of a Three-Level DC-DC Converter Research Article International Journal of Current Engineering and Technology E-ISSN 2277 4106, P-ISSN 2347-5161 2014 INPRESSCO, All Rights Reserved Available at http://inpressco.com/category/ijcet Implementation

More information

The Occurrence of Faults in Permanent Magnet Synchronous Motor Drives and its Effects on the Power Supply Quality

The Occurrence of Faults in Permanent Magnet Synchronous Motor Drives and its Effects on the Power Supply Quality The Occurrence of Faults in Permanent Magnet Synchronous Motor Drives and its Effects on the Power Supply Quality J. O. Estima A. J. Marques Cardoso University of Coimbra, FCTUC/IT Department of Electrical

More information

DOWNLOAD PDF POWER ELECTRONICS DEVICES DRIVERS AND APPLICATIONS

DOWNLOAD PDF POWER ELECTRONICS DEVICES DRIVERS AND APPLICATIONS Chapter 1 : Power Electronics Devices, Drivers, Applications, and Passive theinnatdunvilla.com - Google D Download Power Electronics: Devices, Drivers and Applications By B.W. Williams - Provides a wide

More information

II. PROPOSED CLOSED LOOP SPEED CONTROL OF PMSM BLOCK DIAGRAM

II. PROPOSED CLOSED LOOP SPEED CONTROL OF PMSM BLOCK DIAGRAM Closed Loop Speed Control of Permanent Magnet Synchronous Motor fed by SVPWM Inverter Malti Garje 1, D.R.Patil 2 1,2 Electrical Engineering Department, WCE Sangli Abstract This paper presents very basic

More information

Three Phase PFC and Harmonic Mitigation Using Buck Boost Converter Topology

Three Phase PFC and Harmonic Mitigation Using Buck Boost Converter Topology Three Phase PFC and Harmonic Mitigation Using Buck Boost Converter Topology Riya Philip 1, Reshmi V 2 Department of Electrical and Electronics, Amal Jyothi College of Engineering, Koovapally, India 1,

More information

Space Vector PWM Voltage Source Inverter Fed to Permanent Magnet Synchronous Motor

Space Vector PWM Voltage Source Inverter Fed to Permanent Magnet Synchronous Motor International Journal of Engineering Research and Development e-issn: 2278-067X, p-issn: 2278-800X, www.ijerd.com Volume 12, Issue 6 (June 2016), PP.50-60 Space Vector PWM Voltage Source Inverter Fed to

More information

HARDWARE IMPLEMENTATION OF DIGITAL SIGNAL CONTROLLER FOR THREE PHASE VECTOR CONTROLLED INDUCTION MOTOR

HARDWARE IMPLEMENTATION OF DIGITAL SIGNAL CONTROLLER FOR THREE PHASE VECTOR CONTROLLED INDUCTION MOTOR HARDWARE IMPLEMENTATION OF DIGITAL SIGNAL CONTROLLER FOR THREE PHASE VECTOR CONTROLLED INDUCTION MOTOR SOHEIR M. A. ALLAHON, AHMED A. ABOUMOBARKA, MAGD A. KOUTB, H. MOUSA Engineer,Faculty of Electronic

More information

Mitigating Voltage Sag Using Dynamic Voltage Restorer

Mitigating Voltage Sag Using Dynamic Voltage Restorer Mitigating Voltage Sag Using Dynamic Voltage Restorer Sumit A. Borakhade 1, R.S. Pote 2 1 (M.E Scholar Electrical Engineering, S.S.G.M.C.E. / S.G.B.A.U. Amravati, India) 2 (Associate Professor, Electrical

More information

THE rapid development of power electronics in recent

THE rapid development of power electronics in recent International Journal of Scientific & Engineering Research Volume 3, Issue 6, June-2012 1 A COMPARISON OF WITH AND WITHOUT AC- DC MULTIPULSE CONVERTER FOR VECTOR CONTROL PWM CSI IM DRIVE NAGABABU THOTA,

More information

CHAPTER 6 CURRENT REGULATED PWM SCHEME BASED FOUR- SWITCH THREE-PHASE BRUSHLESS DC MOTOR DRIVE

CHAPTER 6 CURRENT REGULATED PWM SCHEME BASED FOUR- SWITCH THREE-PHASE BRUSHLESS DC MOTOR DRIVE 125 CHAPTER 6 CURRENT REGULATED PWM SCHEME BASED FOUR- SWITCH THREE-PHASE BRUSHLESS DC MOTOR DRIVE 6.1 INTRODUCTION Permanent magnet motors with trapezoidal back EMF and sinusoidal back EMF have several

More information

MODELING AND SIMULATION OF Z- SOURCE INVERTER

MODELING AND SIMULATION OF Z- SOURCE INVERTER From the SelectedWorks of suresh L 212 MODELING AND SIMULATION OF Z- SOURCE INVERTER suresh L Available at: https://works.bepress.com/suresh_l/1/ MODELING AND SIMULATION OF Z-SOURCE INVERTER 1 SURESH L.,

More information

I. INTRODUCTION. 10

I. INTRODUCTION.  10 Closed-loop speed control of bridgeless PFC buck- boost Converter-Fed BLDC motor drive Sanjay S Siddaganga Institute Of Technology/Electrical & Electronics, Tumkur, India Email: sanjayshekhar04@gmail.com

More information

Usha Nandhini.M #1, Kaliappan.S *2, Dr. R. Rajeswari #3 #1 PG Scholar, Department of EEE, Kumaraguru College of Technology, Coimbatore, India

Usha Nandhini.M #1, Kaliappan.S *2, Dr. R. Rajeswari #3 #1 PG Scholar, Department of EEE, Kumaraguru College of Technology, Coimbatore, India A Power Factor Corrector DC-DC Buck-Boost Converter fed BLDC Motor Usha Nandhini.M #1, Kaliappan.S *2, Dr. R. Rajeswari #3 #1 PG Scholar, Department of EEE, Kumaraguru College of Technology, Coimbatore,

More information

CHAPTER 6 BRIDGELESS PFC CUK CONVERTER FED PMBLDC MOTOR

CHAPTER 6 BRIDGELESS PFC CUK CONVERTER FED PMBLDC MOTOR 105 CHAPTER 6 BRIDGELESS PFC CUK CONVERTER FED PMBLDC MOTOR 6.1 GENERAL The line current drawn by the conventional diode rectifier filter capacitor is peaked pulse current. This results in utility line

More information

SPEED CONTROL OF BRUSHLES DC MOTOR

SPEED CONTROL OF BRUSHLES DC MOTOR SPEED CONTROL OF BRUSHLES DC MOTOR Kajal D. Parsana 1, Prof. H.M. Karkar 2, Prof. I.N. Trivedi 3 1 Department of Electrical Engineering, Atmiya Institute of Technology & Science, Rajkot, India. kajal.parsana@gmail.com

More information

Three Phase Parallel Multilevel Inverter Fed Induction Motor Using POD Modulation Scheme

Three Phase Parallel Multilevel Inverter Fed Induction Motor Using POD Modulation Scheme International Journal of Innovation and Applied Studies ISSN 2028-9324 Vol. 7 No. 3 Aug. 2014, pp. 1209-1214 2014 Innovative Space of Scientific Research Journals http://www.ijias.issr-journals.org/ Three

More information

Performance Analysis of Induction Motor Drive Fed by VSI for Various Modulation Index

Performance Analysis of Induction Motor Drive Fed by VSI for Various Modulation Index Performance Analysis of Induction Motor Drive Fed by VSI for Various Modulation Index Amit Kumar Sharma 1, Ashok Kumar Sharma 2, Kavita Nagar 3 123 Department of Electrical Engineering, University College

More information

Hardware Implementation of SPWM Based Diode Clamped Multilevel Invertr

Hardware Implementation of SPWM Based Diode Clamped Multilevel Invertr Hardware Implementation of SPWM Based Diode Clamped Multilevel Invertr Darshni M. Shukla Electrical Engineering Department Government Engineering College Valsad, India darshnishukla@yahoo.com Abstract:

More information

Svpwm Technique to Eliminate Harmonics and Power Factor Improvement Using Hybrid Power Filter and By Using Dsp Tms 320lf2407

Svpwm Technique to Eliminate Harmonics and Power Factor Improvement Using Hybrid Power Filter and By Using Dsp Tms 320lf2407 International Journal of Engineering Research and Development ISSN: 2278-067X, Volume 1, Issue 4 (June 2012), PP.17-25 www.ijerd.com Svpwm Technique to Eliminate Harmonics and Power Factor Improvement

More information

CHAPTER 2 CURRENT SOURCE INVERTER FOR IM CONTROL

CHAPTER 2 CURRENT SOURCE INVERTER FOR IM CONTROL 9 CHAPTER 2 CURRENT SOURCE INVERTER FOR IM CONTROL 2.1 INTRODUCTION AC drives are mainly classified into direct and indirect converter drives. In direct converters (cycloconverters), the AC power is fed

More information

A VARIABLE SPEED PFC CONVERTER FOR BRUSHLESS SRM DRIVE

A VARIABLE SPEED PFC CONVERTER FOR BRUSHLESS SRM DRIVE A VARIABLE SPEED PFC CONVERTER FOR BRUSHLESS SRM DRIVE Mrs. M. Rama Subbamma 1, Dr. V. Madhusudhan 2, Dr. K. S. R. Anjaneyulu 3 and Dr. P. Sujatha 4 1 Professor, Department of E.E.E, G.C.E.T, Y.S.R Kadapa,

More information

SINGLE PHASE THIRTY ONE LEVEL INVERTER USING EIGHT SWITCHES TOWARDS THD REDUCTION

SINGLE PHASE THIRTY ONE LEVEL INVERTER USING EIGHT SWITCHES TOWARDS THD REDUCTION SINGLE PHASE THIRTY ONE LEVEL INVERTER USING EIGHT SWITCHES TOWARDS THD REDUCTION T.Ramachandran 1, P. Ebby Darney 2 and T. Sreedhar 3 1 Assistant Professor, Dept of EEE, U.P, Subharti Institute of Technology

More information

Design of A Closed Loop Speed Control For BLDC Motor

Design of A Closed Loop Speed Control For BLDC Motor International Refereed Journal of Engineering and Science (IRJES) ISSN (Online) 2319-183X, (Print) 2319-1821 Volume 3, Issue 11 (November 214), PP.17-111 Design of A Closed Loop Speed Control For BLDC

More information

Efficiency Optimized Brushless DC Motor Drive. based on Input Current Harmonic Elimination

Efficiency Optimized Brushless DC Motor Drive. based on Input Current Harmonic Elimination Efficiency Optimized Brushless DC Motor Drive based on Input Current Harmonic Elimination International Journal of Power Electronics and Drive System (IJPEDS) Vol. 6, No. 4, December 2015, pp. 869~875

More information

DIRECT TORQUE CONTROL OF THREE PHASE INDUCTION MOTOR BY USING FOUR SWITCH INVERTER

DIRECT TORQUE CONTROL OF THREE PHASE INDUCTION MOTOR BY USING FOUR SWITCH INVERTER DIRECT TORQUE CONTROL OF THREE PHASE INDUCTION MOTOR BY USING FOUR SWITCH INVERTER Mr. Aniket C. Daiv. TSSM's BSCOER, Narhe ABSTRACT Induction motor proved its importance, since its invention and has been

More information

Implementation of high-power Bidirectional dc-dc Converter for Aerospace Applications

Implementation of high-power Bidirectional dc-dc Converter for Aerospace Applications Implementation of high-power Bidirectional dc-dc Converter for Aerospace Applications Sabarinadh.P 1,Barnabas 2 and Paul glady.j 3 1,2,3 Electrical and Electronics Engineering, Sathyabama University, Jeppiaar

More information

Brushless DC Motor Drive using Modified Converter with Minimum Current Algorithm

Brushless DC Motor Drive using Modified Converter with Minimum Current Algorithm Brushless DC Motor Drive using Modified Converter with Minimum Current Algorithm Ajin Sebastian PG Student Electrical and Electronics Engineering Mar Athanasius College of Engineering Kerala, India Benny

More information

Study of Unsymmetrical Cascade H-bridge Multilevel Inverter Design for Induction Motor

Study of Unsymmetrical Cascade H-bridge Multilevel Inverter Design for Induction Motor Study of Unsymmetrical Cascade H-bridge Multilevel Inverter Design for Induction Motor Pinky Arathe 1, Prof. Sunil Kumar Bhatt 2 1Research scholar, Central India Institute of Technology, Indore, (M. P.),

More information

International Journal of Intellectual Advancements and Research in Engineering Computations

International Journal of Intellectual Advancements and Research in Engineering Computations www.ijiarec.com MAR-2015 International Journal of Intellectual Advancements and Research in Engineering Computations SPEED CONTROL OF BLDC MOTOR BY USING UNIVERSAL BRIDGE WITH ABSTRACT ISSN: 2348-2079

More information

A Series-Connected Multilevel Inverter Topology for Squirrel-Cage Induction Motor Drive

A Series-Connected Multilevel Inverter Topology for Squirrel-Cage Induction Motor Drive Vol.2, Issue.3, May-June 2012 pp-1028-1033 ISSN: 2249-6645 A Series-Connected Multilevel Inverter Topology for Squirrel-Cage Induction Motor Drive B. SUSHMITHA M. tech Scholar, Power Electronics & Electrical

More information

Ripple Reduction Using Seven-Level Shunt Active Power Filter for High-Power Drives and Non- Linear Load System

Ripple Reduction Using Seven-Level Shunt Active Power Filter for High-Power Drives and Non- Linear Load System Ripple Reduction Using Seven-Level Shunt Active Power Filter for High-Power Drives and Non- Linear Load System #1 B. Gopinath- P.G Student, #2 Dr. Abdul Ahad- Professor&HOD, NIMRA INSTITUTE OF SCIENCE

More information

Failure study on Increased Number of Phases for the Optimum Design of BLDC Motor

Failure study on Increased Number of Phases for the Optimum Design of BLDC Motor Failure study on Increased Number of Phases for the Optimum Design of BLDC Motor Kiran George Shinoy K. S. Sija Gopinathan Department of Electrical Engineering Sci. /Engr. Associate Professor M A College

More information

A SPWM CONTROLLED THREE-PHASE UPS FOR NONLINEAR LOADS

A SPWM CONTROLLED THREE-PHASE UPS FOR NONLINEAR LOADS http:// A SPWM CONTROLLED THREE-PHASE UPS FOR NONLINEAR LOADS Abdul Wahab 1, Md. Feroz Ali 2, Dr. Abdul Ahad 3 1 Student, 2 Associate Professor, 3 Professor, Dept.of EEE, Nimra College of Engineering &

More information

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY A PATH FOR HORIZING YOUR INNOVATIVE WORK INDUCTION MOTOR DRIVE WITH SINGLE DC LINK TO MINIMIZE ZERO SEQUENCE CURRENT IN

More information

RCL filter to suppress motor terminal overvoltage in PWM inverter fed Permanent Magnet synchronous motor with long cable leads

RCL filter to suppress motor terminal overvoltage in PWM inverter fed Permanent Magnet synchronous motor with long cable leads RCL filter to suppress motor terminal overvoltage in PWM inverter fed Permanent Magnet synchronous motor with long cable leads M.B.RATHNAPRIYA1 A.JAGADEESWARAN2 M.E scholar, Department of EEE Sona College

More information

ADVANCED ROTOR POSITION DETECTION TECHNIQUE FOR SENSORLESS BLDC MOTOR CONTROL

ADVANCED ROTOR POSITION DETECTION TECHNIQUE FOR SENSORLESS BLDC MOTOR CONTROL International Journal of Soft Computing and Engineering (IJSCE) ISSN: 3137, Volume, Issue-1, March 1 ADVANCED ROTOR POSITION DETECTION TECHNIQUE FOR SENSORLESS BLDC MOTOR CONTROL S.JOSHUWA, E.SATHISHKUMAR,

More information

Effective Algorithm for Reducing DC Link Neutral Point Voltage and Total Harmonic Distortion for Five Level Inverter

Effective Algorithm for Reducing DC Link Neutral Point Voltage and Total Harmonic Distortion for Five Level Inverter Effective Algorithm for Reducing DC Link Neutral Point Voltage Total Harmonic Distortion for Five Level Inverter S. Sunisith 1, K. S. Mann 2, Janardhan Rao 3 sunisith@gmail.com, hodeee.gnit@gniindia.org,

More information

Enhancement of Power Quality using active power filter in a Medium-Voltage Distribution Network switching loads

Enhancement of Power Quality using active power filter in a Medium-Voltage Distribution Network switching loads Vol.2, Issue.2, Mar-Apr 2012 pp-431-435 ISSN: 2249-6645 Enhancement of Power Quality using active power filter in a Medium-Voltage Distribution Network switching loads M. CHANDRA SEKHAR 1, B. KIRAN BABU

More information

POWER ELECTRONICS. Converters, Applications, and Design. NED MOHAN Department of Electrical Engineering University of Minnesota Minneapolis, Minnesota

POWER ELECTRONICS. Converters, Applications, and Design. NED MOHAN Department of Electrical Engineering University of Minnesota Minneapolis, Minnesota POWER ELECTRONICS Converters, Applications, and Design THIRD EDITION NED MOHAN Department of Electrical Engineering University of Minnesota Minneapolis, Minnesota TORE M. UNDELAND Department of Electrical

More information

International Journal of Advance Engineering and Research Development

International Journal of Advance Engineering and Research Development Scientific Journal of Impact Factor (SJIF): 3.134 International Journal of Advance Engineering and Research Development Volume 3, Issue 1, January -2016 e-issn (O): 2348-4470 p-issn (P): 2348-6406 Design

More information

Speed Control Of Transformer Cooler Control By Using PWM

Speed Control Of Transformer Cooler Control By Using PWM Speed Control Of Transformer Cooler Control By Using PWM Bhushan Rakhonde 1, Santosh V. Shinde 2, Swapnil R. Unhone 3 1 (assistant professor,department Electrical Egg.(E&P), Des s Coet / S.G.B.A.University,

More information

Park s Vector Approach to detect an inter turn stator fault in a doubly fed induction machine by a neural network

Park s Vector Approach to detect an inter turn stator fault in a doubly fed induction machine by a neural network Park s Vector Approach to detect an inter turn stator fault in a doubly fed induction machine by a neural network ABSTRACT Amel Ourici and Ahmed Ouari Department of Computer Engineering, Badji Mokhtar

More information

Mr. DILIP J. Final Year Mtech Student Dept of EEE The Oxford College of Engineering, Bangalore

Mr. DILIP J. Final Year Mtech Student Dept of EEE The Oxford College of Engineering, Bangalore International Journal of Research Studies in Electrical and Electronics Engineering (IJRSEEE) Volume 1, Issue 1, June 2015, PP 9-17 www.arcjournals.org The Proposed Research Technology and Data Implementation

More information

Sascha Stegen School of Electrical Engineering, Griffith University, Australia

Sascha Stegen School of Electrical Engineering, Griffith University, Australia Sascha Stegen School of Electrical Engineering, Griffith University, Australia Electrical Machines and Drives Motors Generators Power Electronics and Drives Open-loop inverter-fed General arrangement of

More information

ON-LINE NONLINEARITY COMPENSATION TECHNIQUE FOR PWM INVERTER DRIVES

ON-LINE NONLINEARITY COMPENSATION TECHNIQUE FOR PWM INVERTER DRIVES INTERNATIONAL JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY (IJEET) Proceedings of the International Conference on Emerging Trends in Engineering and Management (ICETEM14) ISSN 0976 6545(Print) ISSN 0976

More information

REDUCTION OF HARMONIC DISTORTION IN BLDC DRIVE USING BL-BUCK BOOST CONVERTER BLDC DRIVE

REDUCTION OF HARMONIC DISTORTION IN BLDC DRIVE USING BL-BUCK BOOST CONVERTER BLDC DRIVE International Journal of Electrical Engineering & Technology (IJEET) Volume 7, Issue 5, Sep Oct, 2016, pp.79 88, Article ID: IJEET_07_05_008 Available online at http://www.iaeme.com/ijeet/issues.asp?jtype=ijeet&vtype=7&itype=5

More information

Study of Harmonics and THD of Nine Phase PWM Inverter Drive with CLC Filter for motor drive applications

Study of Harmonics and THD of Nine Phase PWM Inverter Drive with CLC Filter for motor drive applications International Journal of Electronics Engineering Research. ISSN 0975-6450 Volume 9, Number 3 (2017) pp. 369-376 Research India Publications http://www.ripublication.com Study of Harmonics and THD of Nine

More information

Simulation Study of MOSFET Based Drive Circuit Design of Sensorless BLDC Motor for Space Vehicle

Simulation Study of MOSFET Based Drive Circuit Design of Sensorless BLDC Motor for Space Vehicle Simulation Study of MOSFET Based Drive Circuit Design of Sensorless BLDC Motor for Space Vehicle Rajashekar J.S. 1 and Dr. S.C. Prasanna Kumar 2 1 Associate Professor, Dept. of Instrumentation Technology,

More information

Speed Control of Induction Motor using Multilevel Inverter

Speed Control of Induction Motor using Multilevel Inverter Speed Control of Induction Motor using Multilevel Inverter 1 Arya Shibu, 2 Haritha S, 3 Renu Rajan 1, 2, 3 Amrita School of Engineering, EEE Department, Amritapuri, Kollam, India Abstract: Multilevel converters

More information

Z-SOURCE INVERTER BASED DVR FOR VOLTAGE SAG/SWELL MITIGATION

Z-SOURCE INVERTER BASED DVR FOR VOLTAGE SAG/SWELL MITIGATION Z-SOURCE INVERTER BASED DVR FOR VOLTAGE SAG/SWELL MITIGATION 1 Arsha.S.Chandran, 2 Priya Lenin 1 PG Scholar, 2 Assistant Professor 1 Electrical & Electronics Engineering 1 Mohandas College of Engineering

More information

A NEW CIRCUIT TOPOLOGY FOR OPEN CIRCUIT AND SHORT CIRCUIT FAULT TOLERANT DC-DC CONVERTER

A NEW CIRCUIT TOPOLOGY FOR OPEN CIRCUIT AND SHORT CIRCUIT FAULT TOLERANT DC-DC CONVERTER Vol.2, Issue.2, Mar-Apr 2012 pp-303-309 ISSN: 2249-6645 A NEW CIRCUIT TOPOLOGY FOR OPEN CIRCUIT AND SHORT CIRCUIT FAULT TOLERANT DC-DC CONVERTER P. KRISHNA CHAND 1, P.SIVA SANKAR 2 *(Student, Department

More information

Resonant Converter Forreduction of Voltage Imbalance in a PMDC Motor

Resonant Converter Forreduction of Voltage Imbalance in a PMDC Motor Resonant Converter Forreduction of Voltage Imbalance in a PMDC Motor Vaisakh. T Post Graduate, Power Electronics and Drives Abstract: A novel strategy for motor control is proposed in the paper. In this

More information

TABLE OF CONTENTS CHAPTER NO. TITLE PAGE NO. LIST OF TABLES LIST OF FIGURES LIST OF SYMBOLS AND ABBREVIATIONS

TABLE OF CONTENTS CHAPTER NO. TITLE PAGE NO. LIST OF TABLES LIST OF FIGURES LIST OF SYMBOLS AND ABBREVIATIONS vii TABLE OF CONTENTS CHAPTER NO. TITLE PAGE NO. ABSTRACT LIST OF TABLES LIST OF FIGURES LIST OF SYMBOLS AND ABBREVIATIONS iii xii xiii xxi 1 INTRODUCTION 1 1.1 GENERAL 1 1.2 LITERATURE SURVEY 1 1.3 OBJECTIVES

More information

CHAPTER-III MODELING AND IMPLEMENTATION OF PMBLDC MOTOR DRIVE

CHAPTER-III MODELING AND IMPLEMENTATION OF PMBLDC MOTOR DRIVE CHAPTER-III MODELING AND IMPLEMENTATION OF PMBLDC MOTOR DRIVE 3.1 GENERAL The PMBLDC motors used in low power applications (up to 5kW) are fed from a single-phase AC source through a diode bridge rectifier

More information

A Review: Sensorless Control of Brushless DC Motor

A Review: Sensorless Control of Brushless DC Motor A Review: Sensorless Control of Brushless DC Motor Neha Gupta, M.Tech Student, Department of Electrical Engineering, Madan Mohan Malaviya Engineering College, Gorakhpur 273010 (U.P), India Dr.A.K. Pandey,

More information

SERIES ACTIVE power filters have proved to be an interesting

SERIES ACTIVE power filters have proved to be an interesting 928 IEEE TRANSACTIONS ON POWER ELECTRONICS, VOL. 14, NO. 5, SEPTEMBER 1999 A Fault Protection Scheme for Series Active Power Filters Luis A. Morán, Senior Member, IEEE, Ivar Pastorini, Juan Dixon, Senior

More information

A SPECIAL TRANSFORMER CONNECTION FOR THREE- PHASE TO FIVE-PHASE TRANSFORMATION

A SPECIAL TRANSFORMER CONNECTION FOR THREE- PHASE TO FIVE-PHASE TRANSFORMATION A SPECIAL TRANSFORMER CONNECTION FOR THREE- PHASE TO FIVE-PHASE TRANSFORMATION M C V SURESH 1, G PURUSHOTHAM 2 1 (EEE, Sri Venkateswara College of Engineering, India) 2 (EEE, Sri Venkateswara College of

More information

IN MANY industrial applications, ac machines are preferable

IN MANY industrial applications, ac machines are preferable IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, VOL. 46, NO. 1, FEBRUARY 1999 111 Automatic IM Parameter Measurement Under Sensorless Field-Oriented Control Yih-Neng Lin and Chern-Lin Chen, Member, IEEE Abstract

More information

Simulation of Interleaved Buck Converter Fed PMBLDC Drive System with Input Disturbance

Simulation of Interleaved Buck Converter Fed PMBLDC Drive System with Input Disturbance Simulation of Interleaved Buck Converter Fed PMBLDC Drive System with Input Disturbance S. Prakash 1, Dr. R. Dhanasekaran 2 1 Research Scholar, St.Peter s University,Chennai, Tamilnadu, India. 2 Director-Research,

More information