General Information. * Required
|
|
- Bernadette Garrison
- 5 years ago
- Views:
Transcription
1 General Information * Required General * Plant Name * Company Name * Name of individual completing data * of individual completing data * Phone of individual completing data * Has any data in any sheet changed from previous year * PJM TO area * Plant code * Commercial Operation Year * Prime Mover Code * Ownership Code Location * County * City * State * Zip Energy Source Code * A B C D
2 E Generator Capability * Name Plate (MW) * Unit Maximum (MW) * Unit Minimum (MW) * Total Gross Energy Summer Winter * Auxiliary load (MW) * Auxiliary load (MVAR) * Station Load (MW) * Station Load (MVAR) Total Reactive Power Capability at Max Gross Energy Output * Leading (MVAR) * Lagging (MVAR)
3
4 Auxiliary Loads are those loads related to the operation of a specific generator. Fox example any fans or pumps etc. The station load is also known as house load. These are loads related to the facility where the power plant is located but not related to the operation of the power plant. This tends to be constant. Underexcited Overexcited
5 Synchronous Gen Parameters * Required * Want to submit data for a Synchronous Generator? Please Select... Provide individual generator capability (All values requested here are for individual units) * Machine ID (e.g. ST, CT, CT1, CT2, ST2, etc.): Note: List all the machine IDs that these data corresponds (e.g. CT1, CT2). * MVA base: * Terminal voltage: * Nominal power factor: * Unit maximum net capacity output (unit CIR): * Unit gross energy output: * Unit reactive power capability at max gross energy output - leading: * Unit reactive power capability at max gross energy output - lagging: Unit auxiliary load at max gross energy power output: * Where is the auxiliary load being connected? Please provide diagram illustrating aux load configuration. * Any additional comments on the capability (Aux Load): Generator Parameters All reactances and resistance values in on Machine MVA Base * Combined turbine-generator-exciter inertia, H: * Speed damping coefficient, D: Generator Saturation * Generator saturation at 1.0 p.u. voltage, S (1.0): * Generator saturation at 1.2 p.u. voltage, S (1.2):
6 Unsaturated Reactances * Direct axis synchronous reactance, Xd(i): * Direct axis transient reactance, X'd(i): * Direct axis sub-transient reactance, X"d(i): * Quadrature axis synchronous reactance, Xq(i): * Quadrature axis transient reactance, X'q(i): * Quadrature axis sub-transient reactance, X"q(i): * Stator leakage reactance, Xl: * Negative sequence reactance, X2(i): * Zero sequence reactance, X0(i): Saturated Reactances * Saturated subtransient reactance, X"d(v): * Negative sequence reactance, X2(v): * Zero sequence reactance, X0(v): Resistances * DC armature resistance, Ra: * Positive sequence resistance, R1: * Negative sequence resistance, R2: * Zero sequence resistance, R0: Time Constants * Direct axis transient open circuit, T'do: * Direct axis sub-transient open circuit, T"do: * Quadrature axis transient open circuit, T'qo: * Quadrature axis sub-transient open circuit, T"qo: * Armature three-phase short circuit, Ta3: Control Systems Select the appropriate dynamic model
7 * Exciter * If any of the above models are not submitted, then explanation is required: * Governor: * If any of the above models are not submitted, then explanation is required: * Power System Stabilizer (PSS): * If any of the above models are not submitted, then explanation is required: Additional Information: Synchronous Transformer * Want to submit data for a Generator Step-up Transformer (GSU)? Please complete all required information below. If you do not wish to submit a transformer for this turbine, please select "No" in the drop down above. Generator Step-Up (GSU) Transformer Form Note: Main Transformer information is requested in a separate form. * MVA base: Total Transformer Ratings (MVA) e.g. OA/FA1/FA2 * Rating 1:
8 * Rating 2: * Rating 3: * Select transformer windings: Impedances (All Values in on Transformer MVA base) * (a) High-side to low-side: * (b) High-side to tertiary: * (c) Low-side to tertiary: Winding Voltages (kv) * High-side: * Low-side: * Tertiary: Winding Connection Types (Delta, Wye, Wye Gnd, etc) * High-side: * Low-side: * Tertiary: * Tap position: Off-nominal Turns Ratio: Number of taps: Step size: Any additional comments on the transformer? Example: Specify machine ID
9 No Only fill the data below if 'Yes' is selected on the le MVA KV Summer Winter MW MVAR Underexcited MVAR MW MVAR Overexcited Please select... Load related to the operations of the plant (e.g. fans, pumps, etc.) Pink label a 'Location o dropdown kws/kva P.U. 1 < H < 10 0 D < 3 0 < S1.0
10 S1.0 < S1.2 xd < 2.5 x'd < 0.5 x xd x"d < x'd xq < xd x'q < xq x"q < x'q X"d(v) < X"d(i) Ohms sec sec sec sec sec 1. < T( do < 10.) < T"do < T qo T"qo Ta 0.1
11 Please select... Please select... Please select... Please select... Only fill the data below if 'Yes' is MVA MVA
12 MVA MVA Please select... R jx X/R If Three Windings was selected f with tertiary in the name are req KV KV KV
13 eft and additional comment box is only required if other than two options above' was selected for above
14
15 If Other or N/A is selected for Exciter textbox on the left will be required If Other or N/A is selected for Governer textbox on the left will be required If N/A is selected for PSS textbox on the left will be required s selected on the left
16 for transformer winding fields quired
17 Wind Farm Parameters * Required * Want to submit data for a Wind Farm? Please Select... Wind Farm Parameters * Specify manufacturer: * Specify model: * MW Value per turbine (nominal rating): * Number of wind turbines generators of the selected type: * MVA base: MVA * Terminal voltage: KV * Nominal power factor: on MVA base * Stator resistance, R1: Ohms * Saturated sub-transient reactance, X"d(v): on MVA base * Control mode: * Voltage relays? * If yes, provide voltage relay settings: * Frequency relays? * If yes, provide frequency relay settings: * Additional windfarm compensation: Wind Farm Transformer Generator Step-Up (GSU) Transformer Form Note: Main Transformer information is requested in a separate form. * MVA base: MVA
18 Total Transformer Ratings (MVA) e.g. OA/FA1/FA2 * Rating 1: MVA * Rating 2: MVA * Rating 3: MVA * Select transformer windings: Impedances (All Values in on Transformer MVA base) * (a) High-side to low-side: * (b) High-side to tertiary: * (c) Low-side to tertiary: Winding Voltages (kv) * High-side: KV * Low-side: KV * Tertiary: KV Winding Connection Types (Delta, Wye, Wye Gnd, etc) * High-side: * Low-side: * Tertiary: * Tap position: Off-nominal Turns Ratio: Number of taps: Step size: Any additional comments on the transformer?
19 No Only fill the data below if 'Yes' is selected on the le Please select... Please select... Please select... Please select...
20 Please select... R jx X/R If Three Windings was selected f with tertiary in the name are req
21 eft
22 for transformer winding fields quired
23 Inverter Based Parameters * Required * Want to submit data for an Inverted Based Generator? Please Select... Inverter Based Parameters * Type of inverter based technology (e.g solar, storage, etc.): * Specify manufacturer of inverter: * Specify model: * MW Value per inverter: MW * Total number of inverters: * MVA Base per inverter: MVA * Terminal voltage: KV * Nominal power factor: * Nominal output current at full load per inverter: Amps * Maximum fault current output from the inverter: Amps or per unit * How fast can the inverter be disconnected from the system subsequent to a cycles fault? Dynamic modeling * Description of dynamic performance of the inverter during a fault. Please describe how the selected inverter will behave dynamically with respect to real power, reactive power and tripping points for voltage and frequency: Examples: Constant real and reactive power injection during a fault. No tripping allowed. Fluctuations in real and reactive power depending on system conditions. Please submit dynamic model for an accurate representation. * Is the inverter designed with Low Voltage Ride-Through (LVRT) capability? * Voltage relays? * If yes, provide voltage relay settings: * Frequency relays? * If yes, provide frequency relay settings:
24 Note: All inverter based projects greater than 30 MW must submit a dynamic model. Dynamic model may be requested for projects less than 30 MW depending on the area. To avoid delays, whenever available, please submit a dynamic model. Inverter Based Transformer Generator Step-Up (GSU) Transformer Form Note: Main Transformer information is requested in a separate form. * MVA base: MVA Total Transformer Ratings (MVA) e.g. OA/FA1/FA2 * Rating 1: MVA * Rating 2: MVA * Rating 3: MVA * Select transformer windings: Impedances (All Values in on Transformer MVA base) * (a) High-side to low-side: * (b) High-side to tertiary: * (c) Low-side to tertiary: Winding Voltages (kv) * High-side: KV * Low-side: KV * Tertiary: KV Winding Connection Types (Delta, Wye, Wye Gnd, etc) * High-side: * Low-side: * Tertiary: * Tap position: Off-nominal Turns Ratio: Number of taps: Step size: Any additional comments on the transformer?
25
26 No Only fill the data below if 'Yes' is selected on the left Please select... Please select... Please select...
27 Please select... R jx X/R If Three Windings was selected for transfor with tertiary in the name are required
28
29
30 rmer winding fields
31 Main Transformer * Required * Want to submit data for a Main Transformer? Please Select... No Generator Step-Up (GSU) Transformer Form Note: Main Transformer information is requested in a separate form. * MVA base: MVA Total Transformer Ratings (MVA) e.g. OA/FA1/FA2 * Rating 1: MVA * Rating 2: MVA * Rating 3: MVA * Select transformer windings: Impedances (All Values in on Transformer MVA base) * (a) High-side to low-side: * (b) High-side to tertiary: * (c) Low-side to tertiary: Please select... R Winding Voltages (kv) * High-side: KV * Low-side: KV * Tertiary: KV Winding Connection Types (Delta, Wye, Wye Gnd, etc) * High-side: * Low-side: * Tertiary: * Tap position: Off-nominal Turns Ratio: Number of taps: Step size: Any additional comments on the transformer?
32 Only fill the data below if 'Yes' is selected on the left jx X/R If Three Windings was selected for transformer winding fields with tertiary in the name are required
33 Ownership S J W single ownership by respondent jointly owned with another entity wholly owned by an entity other than respondent Prime Mover Codes ST Steam Turbine, including nuclear, geothermal and solar steam (does not include Combined Cycle) GT Combustion (Gas) Turbine IC Internal Combustion (diesel, piston) Engine CA Combined Cycle Steam Part CC Combined Cycle Total Unit (use only for plants/generators that are in planning stage, for which specific generator details cannot be provided) CS Combined Cycle Single Shaft (combustion turbine and steam turbine share a single generator) CT Combined Cycle Combustion Turbine Part (type of coal must be reported as energy source for integrated coal) HY Hydraulic Turbine (includes turbines associated with delivery of water by pipeline) PS Hydraulic Turbine Reversible (pumped storage) PV Photovoltaic WT Wind Turbine CE Compressed Air Energy Storage FC Fuel Cell OT Other NA Unknown at this time (use only for plants/generators that are in planning stage, for which specific generator details cannot be provided) Energy Source Code BIT Anthracite Coal, Bituminous Coal LIG Lignite Coal SUB Subbituminous Coal WC Waste/Other Coal (Anthracite Culm, Bituminous Gob, Fine Coal, Lignite Waste, Waste Coal) SC Coal-based Synfuel and include briquettes, pellets, or extrusions, which are formed by binding materials and processes that recycle material DFO Distillate Fuel Oil (includes all Diesel and No. 1, No. 2, and No. 4 Fuel Oils) JF Jet Fuel KER Kerosene RFO Residual Fuel Oil (includes No. 5 and No. 6 Fuel Oils and Bunker C Fuel Oil)
34 WO PC NG BFG OG PG NUC AB BLQ GEO LFG MSW OBS OBL OBG OTH R SLW SUN TDF WAT WDS WDL WND NA Oil-Other and Waste Oil (Butane (Liquid), Crude Oil, Liquid Byproducts, Oil Waste, Propane (Liquid), Re-Refined Motor Oil, Sludge Oil, Tar Oil) Petroleum Coke Natural Gas Blast-Furnace Gas Other Gas (Butane, Coal Processes, Coke-Oven, Refinery, and other processes) Propane Nuclear (Uranium, Plutonium, Thorium) Agriculture Crop Byproducts/Straw/Energy Crops Black Liquor Geothermal Landfill Gas Municipal Solid Waste Other Biomass Solids (Animal Manure and Waste, Solid Byproducts, and other solid biomass not specified) Other Biomass Liquids (Ethanol, Fish Oil, Liquid Acetonitrile Waste, Medical Waste, Tall Oil, Waste Alcohol, and other biomass liquids not specified) Other Biomass Gases (Digester Gas, Methane, and other biomass gases) Other (Batteries, Chemicals, Coke Breeze, Hydrogen, Pitch, Sulfur, Tar Coal, and miscellaneous technologies) Purchased Steam Sludge Waste Solar (Photovoltaic, Thermal) Tires Water (Conventional, Pumped Storage) Wood/Wood Waste Solids (Paper Pellets, Railroad Ties, Utility Poles, Wood Chips, and other wood solids) Wood Waste Liquids (Red Liquor, Sludge Wood, Spent Sulfite Liquor, and other wood related liquids not specified) Wind Not Available
APPENDIX 1 to LGIP INTERCONNECTION REQUEST FOR A LARGE GENERATING FACILITY
APPENDIX 1 to LGIP INTERCONNECTION REQUEST FOR A LARGE GENERATING FACILITY 1. The undersigned Interconnection Customer submits this request to interconnect its Large Generating Facility with Transmission
More informationGeneration Interconnection Study Data Sheet Synchronous Machines
FOR INTERNAL USE ONLY GTC Project Number: Queue Date: Generation Interconnection Study Data Sheet Synchronous Machines Customers must provide the following information in its entirety. GTC will not proceed
More informationNORTH CAROLINA INTERCONNECTION REQUEST. Utility: Designated Contact Person: Address: Telephone Number: Address:
NORTH CAROLINA INTERCONNECTION REQUEST Utility: Designated Contact Person: Address: Telephone Number: Fax: E-Mail Address: An is considered complete when it provides all applicable and correct information
More informationIDAHO PURPA GENERATOR INTERCONNECTION REQUEST (Application Form)
IDAHO PURPA GENERATOR INTERCONNECTION REQUEST (Application Form) Transmission Provider: IDAHO POWER COMPANY Designated Contact Person: Jeremiah Creason Address: 1221 W. Idaho Street, Boise ID 83702 Telephone
More informationIssued: September 2, 2014 Effective: October 3, 2014 WN U-60 Attachment C to Schedule 152, Page 1 PUGET SOUND ENERGY
WN U-60 Attachment C to Schedule 152, Page 1 SCHEDULE 152 APPLICATION FOR INTERCONNECTING A GENERATING FACILITY TIER 2 OR TIER 3 This Application is considered complete when it provides all applicable
More informationINTERCONNECTION REQUEST FOR A LARGE GENERATING FACILITY
INTERCONNECTION REQUEST FOR A LARGE GENERATING FACILITY Internal Use Only Date Received Time Received Received By: 1. The undersigned Interconnection Customer submits this request to interconnect its Large
More informationConnection Impact Assessment Application Form
Connection Impact Assessment Application Form This Application Form is for Generators applying for a Connection Impact Assessment (CIA). In certain circumstances, London Hydro may require additional information
More informationGENERATOR INTERCONNECTION APPLICATION Category 5 For All Projects with Aggregate Generator Output of More Than 2 MW
GENERATOR INTERCONNECTION APPLICATION Category 5 For All Projects with Aggregate Generator Output of More Than 2 MW ELECTRIC UTILITY CONTACT INFORMATION Consumers Energy Interconnection Coordinator 1945
More informationForm B. Connection Impact Assessment Application Form Distribution System
Form B Connection Impact Assessment Application Form Distribution System This Application Form is for Generators applying for Connection Impact Assessment ( CIA ). It is important that the Generator provides
More informationInitial Application Form for Connection of Distributed Generation (>10kW)
Please complete the following information and forward to Vector Contact Details Primary Contact (who we should contact for additional information) Contact person Company name Contact numbers Daytime: Cell
More informationPART 1 OWNER/APPLICANT INFORMATION
CALHOUN COUNTY ELECTRIC COOP. ASSN. Application for Operation of Customer-Owned Generation This application should be completed as soon as possible and returned to the Cooperative in order to begin processing
More informationSOUTH CENTRAL INDIANA REMC Application for Operation of Member-Owned Small Power Generation Systems
SOUTH CENTRAL INDIANA REMC Application for Operation of Member-Owned Small Power Generation Systems This application should be completed as soon as possible and returned to the Cooperative in order to
More informationEASTERN ILLINI ELECTRIC COOPERATIVE Application for Operation of Member-Owned Generation
EASTERN ILLINI ELECTRIC COOPERATIVE Application for Operation of Member-Owned Generation This application is to be completed and returned to the Cooperative member service representative in order to begin
More informationEmbedded Generation Connection Application Form
Embedded Generation Connection Application Form This Application Form provides information required for an initial assessment of the Embedded Generation project. All applicable sections must be completed
More informationEmbedded Generation Connection Application Form
Embedded Generation Connection Application Form This Application Form provides information required for an initial assessment of the Embedded Generation project. All applicable sections must be completed
More informationOwner/Customer Name: Mailing Address: City: County: State: Zip Code: Phone Number: Representative: Address: Fax Number:
Interconnection of a Customer-Owned Renewable Generation System of Greater than 100 KW and Less than or Equal to 1 MW to the LCEC Electric Grid Tier 3 Application and Compliance Form Instructions: Complete
More informationGENERATOR INTERCONNECTION APPLICATION FOR ALL PROJECTS WITH AGGREGATE GENERATOR OUTPUT OF MORE THAN 2 MW
GENERATOR INTERCONNECTION APPLICATION FOR ALL PROJECTS WITH AGGREGATE GENERATOR OUTPUT OF MORE THAN 2 MW Electric Utility Contact Information DTE Energy Interconnection Coordinator One Energy Plaza, SB
More informationAPPLICATION FOR INTERCONNECTION & OPERATIONS OF MEMBER-OWNED GENERATION
APPLICATION FOR INTERCONNECTION & OPERATIONS OF MEMBER-OWNED GENERATION This application should be completed and returned to in order to begin processing the request for interconnecting as required by
More informationImpact Assessment Generator Form
Impact Assessment Generator Form This connection impact assessment form provides information for the Connection Assessment and Connection Cost Estimate. Date: (dd/mm/yyyy) Consultant/Developer Name: Project
More informationENGINEERING DATA SUBMITTAL For the Interconnection of Generation System
WHO SHOULD FILE THIS SUBMITTAL: Anyone in the final stages of interconnecting a Generation System with Nodak Electric Cooperative, Inc. This submittal shall be completed and provided to Nodak Electric
More informationConnection Impact Assessment Application
Connection Impact Assessment Application This form is for generators applying for Connection Impact Assessment (CIA) and for generators with a project size >10 kw. Please return the completed form by email,
More informationGENERATOR INTERCONNECTION APPLICATION Category 3 For All Projects with Aggregate Generator Output of More Than 150 kw but Less Than or Equal to 550 kw
GENERATOR INTERCONNECTION APPLICATION Category 3 For All Projects with Aggregate Generator Output of More Than 150 kw but Less Than or Equal to 550 kw ELECTRIC UTILITY CONTACT INFORMATION Consumers Energy
More informationEmbedded Generation Connection Application Form
Embedded Generation Connection Application Form This Application Form provides information required for an initial assessment of the Embedded Generation project. All applicable sections must be completed
More informationGENERATOR INTERCONNECTION APPLICATION FOR ALL PROJECTS WITH AGGREGATE GENERATOR OUTPUT OF MORE THAN 150 KW BUT LESS THAN OR EQUAL TO 550 KW
GENERATOR INTERCONNECTION APPLICATION FOR ALL PROJECTS WITH AGGREGATE GENERATOR OUTPUT OF MORE THAN 150 KW BUT LESS THAN OR EQUAL TO 550 KW Electric Utility Contact Information Detroit Edison Company Interconnection
More informationREQUIREMENTS FOR GENERATING FACILITY INTERCONNECTION TO THE LIPA TRANSMISSION SYSTEM
REQUIREMENTS FOR GENERATING FACILITY INTERCONNECTION TO THE LIPA TRANSMISSION SYSTEM Revised March, 2018 Revised March, 2018 This Page Is Intentionally Blank 1.0 Introduction... 1 2.0 General Requirements...
More informationState of North Dakota Engineering data submittal Page 1 For interconnection of distributed generation to Otter Tail Power Company
Engineering data submittal Page 1 WHO SHOULD FILE THIS SUBMITTAL : Anyone in the final stages of in terconnecting a Generation System with Otter Tail Power. This submittal shall be completed and provided
More informationRemotes Case 2&3 Form REINDEER Cases 2&3 -Connection Impact Assessment (CIA) Application
General Application Information Remotes Case 2&3 Form REINDEER Cases 2&3 -Connection Impact Assessment (CIA) Application Hydro One Remote Communities Inc. Lori.Rice@hydroone.com 1-807-474-2828 This Application
More informationECE 422/522 Power System Operations & Planning/Power Systems Analysis II 5 - Reactive Power and Voltage Control
ECE 422/522 Power System Operations & Planning/Power Systems Analysis II 5 - Reactive Power and Voltage Control Spring 2014 Instructor: Kai Sun 1 References Saadat s Chapters 12.6 ~12.7 Kundur s Sections
More informationAPPENDIX B: Generation Interconnection Application Form
2 APPENDIX B: Generation Interconnection Application Form WHO SHOULD FILE THIS APPLICATION: Anyone expressing interest to install generation which will interconnect with Xcel Energy (Local electric utility)
More informationDistributed Generation Application Form (Generation of Greater than 20 kw to 15 MW)
Distributed Generation Application Form (Generation of Greater than 20 kw to 15 MW) PSC-6028 R(03-04-04) Name & Address Distributed By Name & Address Supplied By Public Service Commission of Wisconsin
More informationSystem Protection and Control Subcommittee
Power Plant and Transmission System Protection Coordination Reverse Power (32), Negative Sequence Current (46), Inadvertent Energizing (50/27), Stator Ground Fault (59GN/27TH), Generator Differential (87G),
More informationTime constants ( s ) Resistance. Other data - Class H /6600 V kva. Efficiencies ( % )(3 phase - Classe H V kva)
Alternators: LSA 5, XL8 Ratings 5 Hz 5 rpm kva 66 V 4 poles kva / kwe - Cos φ =,8 3 phase Duty / Ambient Continuous duty (BR) / 4 C PR* / 4 C PR* / 7 C Temperature Rise Class.H/5 K Class.F/5 K 5 K 63 K
More informationALTERNATOR TECHNICAL DESCRIPTION 1. LSA 53.2 XL13 / 4p. Chargé d'affaire : Karthikeyan GN 1 Moteurs Leroy-Somer +33 (0) xx
ALTERNATOR TECHNICAL DESCRIPTION LSA 53.2 XL3 / 4p LS Reference: 3_66 Date: 426 V4.5G 9/26 Chargé d'affaire : Karthikeyan GN Moteurs LeroySomer +33 ()2 38 6 42 xx Electric Power Generation Orleans prenom.nom@leroysomer.com
More informationPower Plant and Transmission System Protection Coordination of-field (40) and Out-of. of-step Protection (78)
Power Plant and Transmission System Protection Coordination Loss-of of-field (40) and Out-of of-step Protection (78) System Protection and Control Subcommittee Protection Coordination Workshop Phoenix,
More informationFacility Interconnection Requirements for Colorado Springs Utilities Version 03 TABLE OF CONTENTS
TABLE OF CONTENTS 1.0 INTRODUCTION (NERC FAC-001 Requirement R1, R2)... 4 2.0 INTERCONNECTION REQUIREMENTS FOR GENERATION, TRANSMISSION, AND END-USER FACILITIES (NERC FAC-001 Requirements R3 & R4)... 4
More informationS0L1-J1 - Technical Data Sheet
S0L1-J1 - Technical Data Sheet Standards Stamford industrial alternators meet the requirements of the relevant parts of the IEC EN 60034 and the relevant section of other international standards such as
More informationDocument C-29. Procedures for System Modeling: Data Requirements & Facility Ratings. January 5 th, 2016 TFSS Revisions Clean Open Process Posting
Document C-29 Procedures for System Modeling: January 5 th, 2016 TFSS Revisions Clean Open Process Posting Prepared by the SS-37 Working Group on Base Case Development for the Task Force on System Studies.
More informationSetting and Verification of Generation Protection to Meet NERC Reliability Standards
1 Setting and Verification of Generation Protection to Meet NERC Reliability Standards Xiangmin Gao, Tom Ernst Douglas Rust, GE Energy Connections Dandsco LLC. Abstract NERC has recently published several
More informationOPERATING, METERING AND EQUIPMENT PROTECTION REQUIREMENTS FOR PARALLEL OPERATION OF LARGE-SIZE GENERATING FACILITIES GREATER THAN 25,000 KILOWATTS
OPERATING, METERING AND EQUIPMENT PROTECTION REQUIREMENTS FOR PARALLEL OPERATION OF LARGE-SIZE GENERATING FACILITIES GREATER THAN 25,000 KILOWATTS AND MEDIUM-SIZE FACILITIES (5,000-25,000KW) CONNECTED
More informationShort-circuit behavior - Xd ; s-s, transient, subtransient. Chapter 4 - Series Resistance of Transmission Lines
EE 5200 - Lecture 15 Fri Oct 6, 2017 Announcements SYNCH homework posted, due latest Mon 9am Office hrs: EERC 123 4:05-5:55pm W,F (online connect via Zoom) Office: EERC 614. Phone: 906.487.2857 Recommended
More informationS4L1S-D4 Wdg.17 - Technical Data Sheet
- Technical Data Sheet Standards STAMFORD industrial alternators meet the requirements of the relevant parts of the BS EN 60034 and the relevant section of other international standards such as BS5000,
More informationImperial Irrigation District System Planning ATTACHMENT A
ATTACHMENT A A typical System Impact Study includes Power Flow, Transient Stability, Post-Transient Stability, and Short Circuit Analysis. If the size and/or technology type of the project is different
More informationKestrel Power Engineering
[Type text] [Type text] [Type text] Kestrel Power Engineering 1660 Twelve Oaks Way #206, North Palm Beach, FL, 33408 ph (516) 972-8049 01 Subject: Steady State Calculations for This memo compares the steady
More informationPRC Generator Relay Loadability. Guidelines and Technical Basis Draft 5: (August 2, 2013) Page 1 of 76
PRC-025-1 Introduction The document, Power Plant and Transmission System Protection Coordination, published by the NERC System Protection and Control Subcommittee (SPCS) provides extensive general discussion
More informationSpec Information. Reactances Per Unit Ohms
GENERATOR DATA Spec Information Generator Specification Frame: 1647 Type: SR5 No. of Bearings: 1 Winding Type: RANDOM WOUND Flywheel: 21.0 Connection: SERIES STAR Housing: 00 Phases: 3 No. of Leads: 6
More informationIJSER. Fig-1: Interconnection diagram in the vicinity of the RajWest power plant
International Journal of Scientific & Engineering Research, Volume 5, Issue 7, July-2014 696 AN INVESTIGATION ON USE OF POWER SYSTEM STABILIZER ON DYNAMIC STABILITY OF POWER SYSTEM Mr. Bhuwan Pratap Singh
More informationCode No: R Set No. 1
Code No: R05310204 Set No. 1 III B.Tech I Semester Regular Examinations, November 2007 ELECTRICAL MACHINES-III (Electrical & Electronic Engineering) Time: 3 hours Max Marks: 80 Answer any FIVE Questions
More informationNERC Protection Coordination Webinar Series June 30, Dr. Murty V.V.S. Yalla
Power Plant and Transmission System Protection ti Coordination Loss-of-Field (40) and Out-of of-step Protection (78) NERC Protection Coordination Webinar Series June 30, 2010 Dr. Murty V.V.S. Yalla Disclaimer
More informationS4L1D-G41 Wdg Technical Data Sheet
- Technical Data Sheet Standards Stamford industrial alternators meet the requirements of the relevant parts of the BS EN 60034 and the relevant section of other international standards such as BS5000,
More informationRobert W. Cummings - NERC Director of System Analysis and Reliability Initiatives William Herbsleb - Chairman of Frequency Response Standard Drafting
Generator Governor and Information Settings Webinar Robert W. Cummings - NERC Director of System Analysis and Reliability Initiatives William Herbsleb - Chairman of Frequency Response Standard Drafting
More informationCourse ELEC Introduction to electric power and energy systems. Additional exercises with answers December reactive power compensation
Course ELEC0014 - Introduction to electric power and energy systems Additional exercises with answers December 2017 Exercise A1 Consider the system represented in the figure below. The four transmission
More informationGENERATOR DATA JANUARY 30, 2015
GENERATOR DATA JANUARY 30, 2015 For Help Desk Phone Numbers Click here Generator Specification Frame: 1822 Type: SR5 No. of Bearings: 2 Winding Type: FORM WOUND Flywheel: 21.0 Connection: SERIES STAR Housing:
More informationOPERATING, METERING, AND EQUIPMENT PROTECTION REQUIREMENTS FOR PARALLEL OPERATION OF LARGE-SIZE GENERATING FACILITIES GREATER THAN 2,000 KILOWATTS
OPERATING, METERING, AND EQUIPMENT PROTECTION REQUIREMENTS FOR PARALLEL OPERATION OF LARGE-SIZE GENERATING FACILITIES GREATER THAN 2,000 KILOWATTS CONNECTED TO THE DISTRIBUTION SYSTEM ORANGE AND ROCKLAND
More informationPRC Generator Relay Loadability. Guidelines and Technical Basis Draft 4: (June 10, 2013) Page 1 of 75
PRC-025-1 Introduction The document, Power Plant and Transmission System Protection Coordination, published by the NERC System Protection and Control Subcommittee (SPCS) provides extensive general discussion
More informationSYNCHRONOUS MACHINES
SYNCHRONOUS MACHINES The geometry of a synchronous machine is quite similar to that of the induction machine. The stator core and windings of a three-phase synchronous machine are practically identical
More informationGenerator Advanced Concepts
Generator Advanced Concepts Common Topics, The Practical Side Machine Output Voltage Equation Pitch Harmonics Circulating Currents when Paralleling Reactances and Time Constants Three Generator Curves
More informationSystem Protection and Control Subcommittee
Power Plant and Transmission System Protection Coordination Volts Per Hertz (24), Undervoltage (27), Overvoltage (59), and Under/Overfrequency (81) Protection System Protection and Control Subcommittee
More informationAGN 034 Alternator Reactance
Application Guidance Notes: Technical Information from Cummins Generator Technologies AGN 034 Alternator Reactance DEFINITION Reactance Periods Inherent to the design of an alternator are certain internal
More informationNERC Protection Coordination Webinar Series July 15, Jon Gardell
Power Plant and Transmission System Protection Coordination Reverse Power (32), Negative Sequence Current (46), Inadvertent Energizing (50/27), Stator Ground Fault (59GN/27TH), Generator Differential (87G),
More informationHow Full-Converter Wind Turbine Generators Satisfy Interconnection Requirements
How Full-Converter Wind Turbine Generators Satisfy Interconnection Requirements Robert Nelson Senior Expert Engineering Manager and Manager of Codes, Standards, and Regulations Siemens Wind Turbines -
More informationWDG 83 - Technical Data Sheet
HV 804 R WDG 83 - Technical Data Sheet FRAME HV 804 R SPECIFICATIONS & OPTIONS STANDARDS STAMFORD AC generators are designed to meet the performance requirements of IEC EN 60034-1. Other international
More informationSouthern Company Interconnection Requirements for Inverter-Based Generation
Southern Company Interconnection Requirements for Inverter-Based Generation September 19, 2016 Page 1 of 16 All inverter-based generation connected to Southern Companies transmission system (Point of Interconnection
More informationLONG ISLAND POWER AUTHORITY INTERCONNECTION GUIDE FOR INDEPENDENT POWER PRODUCERS
LONG ISLAND POWER AUTHORITY INTERCONNECTION GUIDE FOR INDEPENDENT POWER PRODUCERS LIPA CUSTOMER KWH OUT KWH IN PULSES Part 1: Control and Protection Requirements for Independent Power Producers Part 2:
More informationPM734D - Winding 312. Technical Data Sheet APPROVED DOCUMENT. Generator Solutions AS
PM734D - Winding 312 Technical Data Sheet PM734D SPECIFICATIONS & OPTIONS STANDARDS Marine generators may be certified to Lloyds, DnV, Bureau Veritas, ABS, Germanischer-Lloyd or RINA. Other standards and
More informationPM734F - Winding 312. Technical Data Sheet APPROVED DOCUMENT
PM734F - Winding 312 Technical Data Sheet PM734F SPECIFICATIONS & OPTIONS STANDARDS Marine generators may be certified to Lloyds, DnV, Bureau Veritas, ABS, Germanischer-Lloyd or RINA. Other standards and
More informationHISTORY: How we got to where we are. March 2015 Roy Boyer 1
HISTORY: How we got to where we are March 2015 Roy Boyer 1 Traditional Stability Analysis: 1. Maintain synchronism of synchronous machines 2. Simplifying assumptions: 1. Balanced positive sequence system
More informationNERC Requirements for Setting Load-Dependent Power Plant Protection: PRC-025-1
NERC Requirements for Setting Load-Dependent Power Plant Protection: PRC-025-1 Charles J. Mozina, Consultant Beckwith Electric Co., Inc. www.beckwithelectric.com I. Introduction During the 2003 blackout,
More informationNERC Protection Coordination Webinar Series June 16, Phil Tatro Jon Gardell
Power Plant and Transmission System Protection Coordination Phase Distance (21) and Voltage-Controlled or Voltage-Restrained Overcurrent Protection (51V) NERC Protection Coordination Webinar Series June
More informationPM734B - Technical Data Sheet. Generator Solutions AS
- Technical Data Sheet STANDARDS Marine generators may be certified to Lloyds, DnV, Bureau Veritas, ABS, Germanischer-Lloyd or RINA. Other standards and certifications can be considered on request. DESCRIPTION
More informationPower Plant and Transmission System Protection Coordination
Technical Reference Document Power Plant and Transmission System Protection Coordination NERC System Protection and Control Subcommittee Revision 1 July 2010 Table of Contents 1. Introduction... 1 1.1.
More informationWDG 13 - Technical Data Sheet
LV 804 T WDG 13 - Technical Data Sheet FRAME LV 804 T SPECIFICATIONS & OPTIONS STANDARDS Cummins Generator Technologies industrial generators meet the requirements of BS EN 60034 and the relevant sections
More informationConventional Paper-II-2013
1. All parts carry equal marks Conventional Paper-II-013 (a) (d) A 0V DC shunt motor takes 0A at full load running at 500 rpm. The armature resistance is 0.4Ω and shunt field resistance of 176Ω. The machine
More information1
Guidelines and Technical Basis Introduction The document, Power Plant and Transmission System Protection Coordination, published by the NERC System Protection and Control Subcommittee (SPCS) provides extensive
More informationEH2741 Communication and Control in Electric Power Systems Lecture 2
KTH ROYAL INSTITUTE OF TECHNOLOGY EH2741 Communication and Control in Electric Power Systems Lecture 2 Lars Nordström larsno@kth.se Course map Outline Transmission Grids vs Distribution grids Primary Equipment
More informationPI734E - Winding 312. Technical Data Sheet APPROVED DOCUMENT
- Winding 312 Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS Stamford industrial generators meet the requirements of BS EN 60034 and the relevant sections of other national and international standards
More informationPI734C - Winding 312. Technical Data Sheet APPROVED DOCUMENT
- Winding 312 Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS Stamford industrial generators meet the requirements of BS EN 60034 and the relevant sections of other national and international standards
More informationPI734B - Winding 312. Technical Data Sheet APPROVED DOCUMENT
- Winding 312 Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS Stamford industrial generators meet the requirements of BS EN 60034 and the relevant sections of other national and international standards
More informationPI734C - Technical Data Sheet
PI734C - Technical Data Sheet PI734C SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant sections of other national and international
More informationWDG 71 - Technical Data Sheet
HV 804 R WDG 71 - Technical Data Sheet FRAME HV 804 R SPECIFICATIONS & OPTIONS STANDARDS Cummins Generator Technologies industrial generators meet the requirements of BS EN 60034 and the relevant sections
More informationPI734A - Technical Data Sheet
PI734A - Technical Data Sheet PI734A SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant sections of other national and international
More informationWDG 61 - Technical Data Sheet
HV 804 W WDG 61 - Technical Data Sheet FRAME HV 804 W SPECIFICATIONS & OPTIONS STANDARDS STAMFORD AC generators are designed to meet the performance requirements of IEC EN 60034-1. Other international
More informationWDG 51 - Technical Data Sheet
MV 804 S WDG 51 - Technical Data Sheet FRAME MV 804 S SPECIFICATIONS & OPTIONS STANDARDS STAMFORD AC generators are designed to meet the performance requirements of IEC EN 60034-1. Other international
More informationQUESTIONNAIRE for Wind Farm Power Stations only
TRANSMISSION SYSTEM OPERATOR QUESTIONNAIRE for Wind Farm Power Stations only To be submitted by the Generation Licensees together with the Application for Connection Certificate according to IEC 61400-21
More informationWDG 12 - Technical Data Sheet
LV 804 R WDG 12 - Technical Data Sheet FRAME LV 804 R SPECIFICATIONS & OPTIONS STANDARDS STAMFORD AC generators are designed to meet the performance requirements of IEC EN 60034-1. Other international
More informationWDG 12 - Technical Data Sheet
LV 804 W WDG 12 - Technical Data Sheet FRAME LV 804 W SPECIFICATIONS & OPTIONS STANDARDS STAMFORD AC generators are designed to meet the performance requirements of IEC EN 60034-1. Other international
More informationPAPER-II (Subjective)
PAPER-II (Subjective) 1.(A) Choose and write the correct answer from among the four options given in each case for (a) to (j) below: (a) Improved commutation in d.c machines cannot be achieved by (i) Use
More informationPI734F - Winding 28. Technical Data Sheet APPROVED DOCUMENT
- Winding 28 Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS Stamford industrial generators meet the requirements of BS EN 60034 and the relevant sections of other national and international standards
More informationTransmission Interconnection Requirements for Inverter-Based Generation
Transmission Requirements for Inverter-Based Generation June 25, 2018 Page 1 Overview: Every generator interconnecting to the transmission system must adhere to all applicable Federal and State jurisdictional
More informationTransformer Protection
Transformer Protection Transformer Protection Outline Fuses Protection Example Overcurrent Protection Differential Relaying Current Matching Phase Shift Compensation Tap Changing Under Load Magnetizing
More informationWDG 12 - Technical Data Sheet
LV 804 T WDG 12 - Technical Data Sheet FRAME LV 804 T SPECIFICATIONS & OPTIONS STANDARDS Cummins Generator Technologies industrial generators meet the requirements of BS EN 60034 and the relevant sections
More informationNERC Protection Coordination Webinar Series June 23, Phil Tatro
Power Plant and Transmission System Protection Coordination Volts Per Hertz (24), Undervoltage (27), Overvoltage (59), and Under/Overfrequency (81) Protection NERC Protection Coordination Webinar Series
More informationIf any queries arise ESB Networks DAC can be contacted at or
esbnetworks.ie FORM NC5 EMBEDDED GENERATION FACILITIES Application for a New Connection FOR OFFICIAL USE ONLY B.P. No: MPRN: Introduction This application form outlines the information ESB Networks DAC
More informationWDG 12 - Technical Data Sheet
LV 804 S WDG 12 - Technical Data Sheet FRAME LV 804 S SPECIFICATIONS & OPTIONS STANDARDS Cummins Generator Technologies industrial generators meet the requirements of BS EN 60034 and the relevant sections
More informationIJSER. Rajasthan power system power map is placed in Fig-1. Fig-1: Rajasthan Power System
International Journal of Scientific & Engineering Research, Volume 5, Issue 10, October-2014 789 Increase of Transient Stability of Thermal Power Plant with Power System Stabilizer Mr. Pooran Singh Shekhawat
More informationWDG 07 - Technical Data Sheet
LV 804 S WDG 07 - Technical Data Sheet FRAME LV 804 S SPECIFICATIONS & OPTIONS STANDARDS Cummins Generator Technologies industrial generators meet the requirements of BS EN 60034 and the relevant sections
More informationAppendix C-1. Protection Requirements & Guidelines Non-Utility Generator Connection to Okanogan PUD
A. Introduction Appendix C-1 Protection Requirements & Guidelines to Okanogan PUD The protection requirements identified in this document apply to Non-Utility Generating (NUG) facilities, Independent Power
More informationPower Plant and Transmission System Protection Coordination
Agenda Item 5.h Attachment 1 A Technical Reference Document Power Plant and Transmission System Protection Coordination Draft 6.9 November 19, 2009 NERC System Protection and Control Subcommittee November
More informationPlanners Perspective on Series Compensated Transmission Lines
TOGETHER WE DELIVER Planners Perspective on Series Compensated Transmission Lines Kenneth A. Donohoo, PE Director, System Planning Distribution and Transmission kenneth.donohoo@oncor.com Oncor Electric
More informationPI734F - Winding 07. Technical Data Sheet APPROVED DOCUMENT
- Winding 07 Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS Stamford industrial generators meet the requirements of BS EN 34 and the relevant sections of other national and international standards
More informationCompany Directive STANDARD TECHNIQUE: SD7F/2. Determination of Short Circuit Duty for Switchgear on the WPD Distribution System
Company Directive STANDARD TECHNIQUE: SD7F/2 Determination of Short Circuit Duty for Switchgear on the WPD Distribution System Policy Summary This document provides guidance on calculation of fault levels
More information