General Specifications
|
|
- Leon Pierce
- 5 years ago
- Views:
Transcription
1 General Specifications Digital I/O Modules (for ProSafe-RS) GENERAL This GS provides the hardware specifi cations of the digital I/O modules that can be installed in the Safety Node Unit (SNB10D) and Safety Control Units (SSC10S and SSC10D). STANDARD SPECIFICATIONS Input Module Input modules accept a contact signal from the fi eld. input modules can be dual-redundant. Number of inputs Input signal Input current Contact rating Item External power supply Instantaneous maximum permissible input voltage Input response time Withstand voltage Current consumption Weight External connection 16, collective isolation No-voltage contact ON: 1 kω maximum OFF: 100 kω minimum Specifications 6 ma ± 20% (External power supply, 24 V DC at 0 Ω input) 24 V ± 5%, 10 ma or greater 24 V ± 5% Current capacity: 200 ma 30.0 V DC 40 ms maximum 2 kv AC between input signal and system, 16-input line collectively connected 290 ma maximum (5 V DC) 140 ma maximum (24 V DC) 0.31 kg (with no option codes) Pressure clamp terminal MIL cable Dedicated cable Note: When dedicated cables are used, the module withstand voltage shall be 500 V AC (between input signal lines and system). If MIL connector cables are used, the withstand voltage depends on their cable s electrical specifications. If fi eld wiring diagnostic functions are used, the following diagnostic elements should be installed for individual channels in the vicinity of the fi eld equipment: SCB100 (for defective open circuit detection while accepting off signals) (*1) SCB110 (for defective short-circuit detection while accepting on signals) (*2) *1: Input signals are normally off while in normal operation. *2: Input signals are normally on while in normal operation. Yokogawa Electric Corporation , Nakacho, Musashino-shi, Tokyo, Japan Tel.: Fax.: Copyright Feb st Edition Feb.01,2005
2 2 When the input signals are normally off while in normal operation, connect the SCB100 in parallel with the contact output of the fi eld equipment as given below. SCB100 DCn INn : Field equipment switch When the input signals are normally on while in normal operation, connect the SCB110 in series with the contact output of the fi eld equipment (take care about the polarity taking note of the polarity). F01E.ai SCB110 DCn Red Blue INn When checking for both defective short and open circuits, connect the SCB100 and SCB110 in parallel and series with the contact outputs of the fi eld equipment respectively, as given below. F02E.ai DCn Red Blue SCB110 SCB100 INn F03E.ai
3 3 Output Module Output modules output 24 V DC on/off status signals to fi eld equipment. SDV531 output modules can be dual-redundant. The output modules incorporate fi eld wiring diagnostic features, so they require no wiring diagnosis elements. Item Specifications Number of outputs Output voltage External power supply rating External power supply Output voltage drop Maximum leak current at output off status Output format SDV531 Eight, collective isolation 24 V DC 24 V DC, 5 A minimum 24 V DC ± 5% Current capacity, 5 A 1 V maximum 1.6 ma Current source Maximum load current 0.6 A/output line (4.8 A in total output line) (*1) Output response time Withstand voltage Current consumption Weight External connection 30 ms maximum 2 kv AC (between input signal lines and system), eight input lines collectively connected (negative lines) (*2) 280 ma maximum (5 V DC) 140 ma maximum (24 V DC) 0.28 kg (with no option codes) Pressure clamp terminal MIL cable Dedicated cable *1: If a direct current relay is driven by an output contact, be sure to connect a spark killer diode. *2: When dedicated cables are used, the module s withstand voltage shall be 500 V AC (between input signal lines and system). If MIL connector cables are used, the withstand voltage depends on their cable s electrical specifications.
4 4 EXTERNAL DIMENSIONS Digital Input Module Unit: mm F04E.ai SDV531 Digital Output Module Unit: mm F05E.ai SBC100 and SBC110 Wiring Diagnosis Elements 8±3 250±10 65±5 11±3 F06E.ai
5 5 MODEL AND SUFFIX CODES Digital Input Module Digital input module (16 input channels, collective isolation) Option codes 1 Always 1 /D4A00 /B4S00 /B4S10 /B4D00 /B4D10 /CCC01 /CCC02 3 G3-compatible and temperature-adaptive With signal cable interface adapter [Part name: STD4A-00] With pressure clamp terminal block for digital input (without surge absorber) [Part name: STB4S-00] With pressure clamp terminal block for digital input (with surge absorber) [Part name: STB4S-10] Dual-redundant pressure clamp terminal block for digital input (without surge absorber) (*1) [Part name: STB4D-00] Dual-redundant pressure clamp terminal block for digital input (with surge absorber) (*1) [Part name: STB4D-10] With connector cover for MIL cable (ribbon cable) [Part name: SCCC01] With connector cover for MIL cable (separated cable) [Part name: SCCC02] *1: When this module is used in dual-redundancy, one more module with the same specification is needed, but no option code is required in its module. Digital Output Module SDV531 Digital output module (eight outputs, collective isolation) Option codes 1 Always 1 /D4A00 /B4S00 /B4S10 /B4D00 /B4D10 /CCC01 /CCC02 3 G3-compatible and temperature-adaptive With signal cable interface adapter [Part name: STD4A-00] With pressure clamp terminal block for digital output (without surge absorber) [Part name: STB4S-00] With pressure clamp terminal block for digital output (with surge absorber) [Part name: STB4S-10] Dual-redundant pressure clamp terminal block for digital output (without surge absorber) (*1) [Part name: STB4D-00] Dual-redundant pressure clamp terminal block for digital output (with surge absorber) (*1) [Part name: STB4D-10] With connector cover for MIL cable (ribbon cable) [Part name: SCCC01] With connector cover for MIL cable (separated cable) [Part name: SCCC02] *1: When this module is used in dual-redundancy, one more module with the same specification is needed, but no option code is required in its module.
6 6 Wiring Diagnosis Elements SCB100 Wiring Check Adapter for Digital input (for defective open circuit detection while accepting off signals) (*1) 0 Always 1 (G3-compatible) *1: Eight wires/set SCB110 Wiring check adapter for Digital input (for defective short-circuited detection while accepting on signals) (*1) 0 Always 1 (G3-compatible) *1: Eight wires/set ORDERING INFORMATION Specify the model and suffi x codes when ordering. TRADEMARKS ProSafe is a registered trademark of Yokogawa Electric Corporation. Other company and product names appearing in this document are trademarks or registered trademarks of their respective holders. Subject to change without notice.
General Specifications
General Digital I/O Modules (f FIO) [Release 6] GENERAL This GS covers the hardware specifications of the Digital I/O Modules (FIO) that can be installed in the ESB Bus Node Unit (ANB10S, ANB10D), Optical
More informationGeneral Specifications
General Specifications Digital I/O Modules GS 34P02Q35-01E GENERAL This GS covers the hardware specifications of digital input/output modules that can be installed in an FCN autonomous controller. For
More informationGeneral Specifications
General Model I/O Module (for N-IO) GENERAL This General (GS) provides the hardware specifications of I/O module (for N-IO) that can be mounted on the Base Plate for N-IO I/O (S2BN1D, S2BN4D and S2BN5D).
More informationGeneral Specifications
General I/O Adaptors (for N-IO) GENERAL This General (GS) covers the hardware specifications of I/O adaptors that allow for setting extended functions of the Analog Digital I/O Module (A2MMM843), such
More informationTurbomachinery I/O Modules
General Specifications Turbomachinery I/O Modules GS 33J60F9001EN [Release 6] GENERA This document of General Specification (GS) contains the hardware specifications of the Turbomachinery I/O Modules (FIO).
More informationGeneral Specifications
General I/O Adaptors (for N-IO) GS 33J62F30-01EN [Release 6] GENERAL This General (GS) describes the hardware specifications of I/O adaptors that enable extended functions setting for analog digital I/O
More informationGeneral Specifications
General Analog I/O Modules (for FIO) GS 33J60F60-01N [Release 6] GNRAL This document describes about hardware specifications of Analog I/O Modules (for FIO) to be installed in the SB bus node units (ANB10S
More informationGeneral Specifications
General Specifications Terminal Boards (for IO) GS 33J0H0-01EN GENERAL This document describes the specifications of terminal boards used for IOs of CENTUM VP systems. STANDARD SPECIICATIONS [Release ]
More informationGeneral Specifications
General GS 33K50F60-50 Analog I/O Modules (for FIO) GNRAL This document describes about hardware specifications of Analog I/O Modules (for FIO) to be installed in the SB bus node units (ANB10S and ANB10D),
More informationGeneral Specifications
General Specifications Signal Conditioner Cards OUTLINE Signal Conditioner Cards, which interface to the process, are installed in Signal Conditioner Nests. [Release 6] The signal conditioner cards can
More informationFCJ Autonomous Controller Hardware. Model. Current dissipation Dimensions. Foundation Fieldbus
General s FCJ Autonomous Controller Hardware GENERAL This document describes the general specifications of the FCJ autonomous controller. (FCJ is an acronym of field control junction.)
More informationGeneral Specifications
General Specifications GS J0X02-01E WX2 Series Computing Units (Variable/Fixed Software Type) Moving Average Unit, Dead Time Unit, Velocity Unit, First Order Lug Unit, First Order Lead Unit, Velocity Limiter,
More informationGeneral Specifications
General Specifications Signal Conditioner Cards GS 33K50H80-50E OUTLINE Signal Conditioner Cards, which interface to the process, are installed in Signal Conditioner Nests. [Release 5] The signal conditioner
More informationGeneral Specifications
General Specifications I/O Modules with Built-in Barrier (for FIO) GS 33K50F80-50E GENERAL This document describes about I/O Modules with Built-in Barrier (for FIO) which can be installed in Zone 2 or
More informationGeneral Specifications
General Specifications GS J08X0-0E FX Series Computing Units (Variable/Fixed Software Type) Moving Average Unit, Dead Time Unit, Velocity Unit, First Order Lug Unit, First Order Lead Unit, Velocity Limiter,
More informationGeneral Specifications
General Specifications I/O Modules with Built-in Barrier (for FIO) GS 33K50F80-50E GENERAL This document describes about I/O Modules with Built-in Barrier (for FIO) which can be installed in Zone 2 or
More informationGeneral Specifications
General Specifications GS 77J09X01-01E WX1 Series Computing Units (Variable Software Type) Moving Average Unit, Dead Time Unit, Velocity Unit, First Order Lug Unit, First Order Lead Unit, Velocity Limiter,
More informationTechnical Information
Technical Information Conductivity Analyzer Selection Guide TI 12D08A01-02E Conductivity / Resistivity Analyzers SC4AJ SC8SG SC210G Adapter Mounting Flow-through Type SC450G Conductivity/ Resistivity FLXA
More informationGeneral Specifications
General Specifications GS J08X0-0E FX Series Computing Units (Variable Software Type) Moving Average Unit, Dead Time Unit, Velocity Unit, First Order Lug Unit, First Order Lead Unit, Velocity Limiter,
More informationGeneral Specifications
General Specifications GS J08X0-0E FX Series Computing Units (mv Input/Variable Software Type) Moving Average Unit, Dead Time Unit, Velocity Unit, First Order Lug Unit, First Order Lead Unit, Velocity
More informationFault indicator. Application. SPEF 3A2 C 1MRS MBG Issued: April 1999 Status: Updated Version: B/ Data subject to change without notice
Issued: April 1999 Status: Updated Version: B/08.11.200 Data subject to change without notice Features Versatile, multifunction line fault indicator for distribution networks Overcurrent, earth-fault and
More informationGeneral Specifications
General Specifications YFGW510 Field Wireless Access Point GS 01W02E01-01EN GENERAL This General Specification(GS) describes the hardware specifications for Field Wireless Management Station and specifications
More informationPB-400-CN. Datasheet. IndustryAmp PB-400-CN * Applies to Part Number: *This unit has a CobraNet interface installed
PB-400-CN Datasheet Applies to Part Number: 590403 IndustryAmp PB-400-CN * *This unit has a CobraNet interface installed User Notice: No part of this document including the software described in it may
More informationGeneral Specifications
General Specifications GS 05P01C81-41EN UT52A, UT32A Digital Indicating Controller (DIN Rail Mounting and Wireless Communication Type) Overview The UT52A and UT32A controllers are multi-function I/O device
More informationGeneral Specifications
General Specifications GS 77J01Q08-01E Model VJQ8 Pulse to Analog Converter (Multi-function) (Isolated Single-output and Isolated Dual-output Types) General This plug-in type pulse to analog converter
More informationGeneral Specifications
General Specifications Model UM350 Digital Indicator with Alarms GS 05F0D00E General Model UM350 Digital Indicator with Alarms is a precision alarm instrument with universal input. For excellent monitoring
More informationDatasheet. Octadrive DSP-CN * Applies to Part Number: *This unit has a CobraNet interface installed
OCTADRIVE DSP-CN Datasheet Applies to Part Number: 391030 Octadrive DSP-CN * *This unit has a CobraNet interface installed User Notice: No part of this document including the software described in it may
More informationGeneral Specifications
General pecifications G 33K5F5-5 odels, ptical B Bus Repeater odule for 5km (for FV3 /FV4 ) GRL The ptical B Bus Repeater odule converts the B bus to an optical signal and transmits
More informationTemposonics. Magnetostrictive Linear Position Sensors. EP / EL IO-Link Data Sheet
Temposonics Magnetostrictive Linear Position Sensors EP / EL IO-Link For standard applications Operating temperature up to +75 C (+167 F) Ideal for limited installation space MEASURING TECHNOLOGY The absolute,
More informationTemposonics. Magnetostrictive Linear Position Sensors. EP / EL Analog Data Sheet
Temposonics Magnetostrictive Linear Position Sensors EP / EL Analog For standard applications Position measurement with more than one magnet Ideal for limited installation space MEASURING TECHNOLOGY The
More informationGeneral Specifications
General pecifications G 33K5F5-5 odels, ptical B Bus Repeater odule for 5km (for -/F) GRL The ptical B Bus Repeater odule converts the B bus to an optical signal and transmits it.
More informationGeneral Specifications
General Specifications GS J0X-0E Model MXT Universal Computing Unit (-input, Isolated -output Type) General This plug-in type universal computing unit receives DC current or DC voltage signals, applies
More informationGeneral Specifications
General Specifications MODEL UM0 Digital Indicator with Alarms GS 0F0D00E General Model UM0 Digital Indicator with Alarms is a precision alarm instrument with universal input /8DIN. For excellent monitoring
More informationTemposonics. Magnetostrictive Linear Position Sensors. ER IO-Link Data Sheet
Temposonics Magnetostrictive Linear Position Sensors ER IO-Link Compact sensor model Operating temperature up to +75 C (+167 F) Ideal for flexible mounting MEASURING TECHNOLOGY The absolute, linear position
More informationIntroduction Intrinsic safe system How to select sensors How to select safety barriers...6 Revision Information...
Technical Information FLXA202 2-Wire Analyzer Selection Guide for Intrinsic Safety-type Associated Apparatus TM Contents Introduction...2 1. Intrinsic safe system...3 2. How to select sensors...5 3. How
More informationGeneral Specifications
General Specifications Model UM330 Digital Indicator with Alarms GS 05F0D00E General Model UM330 Digital Indicator with Alarms is a precision alarm instrument with universal input /8DIN. For excellent
More informationTemposonics. Magnetostrictive Linear Position Sensors. ER Analog Data Sheet
Temposonics Magnetostrictive Linear Position Sensors ER Analog Compact sensor model Operating temperature up to +75 C (+167 F) Ideal for flexible mounting MEASURING TECHNOLOGY The absolute, linear position
More informationNPRG860 & NPRG870 perform synchronization and paralleling of generators with electrical network. NPRG860 features a speed adjustment function.
REGULATION AUTOMATIC SYNCHRONIZER for GENERATOR NPRG860 & NPRG870 perform synchronization and paralleling of generators with electrical network. NPRG860 features a speed adjustment function. NPRG870 adds
More informationNPRG860 NPRG870 REGULATION. Automatic Synchronizer for Generator
REGULATION Automatic Synchronizer for Generator NPRG860 & NPRG870 perform synchronization and paralleling of generators with electrical network. NPRG860 features a speed adjustment function. NPRG870 adds
More informationProcontrol P14 89AS30R0100 Module and Application Description Analog Signal Multiplier
Procontrol P14 89AS30R0100 Module and Application Description Analog Signal Multiplier Procontrol P14 89AS30R0100 Analog Signal Multiplier NOTICE TRADEMARKS This document contains information about one
More informationTemposonics. Magnetostrictive Linear Position Sensors. EP2 Analog Data Sheet
Temposonics Magnetostrictive Linear Position Sensors EP2 Analog Optimal price- / performance ratio Position measurement with more than one magnet Smooth & compact Temposonics EP2 Analog MEASURING TECHNOLOGY
More informationGeneral Specifications
General Specifications GS 77M00-0EN Models R-S, R-H, R-T, R-RT, R-LP, R-HP, R-SP, R-SY, R-PS, R-PH, R-PW, R-, R-D6 rrester [Style: S] General This high quality arrester protects electronic instruments
More informationTemposonics. Magnetostrictive Linear Position Sensors. EP / EL Start / Stop Data Sheet
Temposonics Magnetostrictive Linear Position Sensors EP / EL Start / Stop For standard applications Position measurement with more than one magnet Ideal for limited installation space MEASURING TECHNOLOGY
More informationINSULATION / WITHSTANDING Test Instrument series 3153/3159/ST5520
INSULATION / WITHSTANDING Test Instrument series 3153/3159/ST5520 3153 3159 Not CE Marked ST5520 This electrical safety test instrument series is designed for insulation resistance and voltage withstand
More informationPI3L V Quad, 2:1 Mux/DeMux Fast Ethernet LAN Switch w/ Single Enable. Description. Features. Applications. Pin Configuration.
Features R ON is 4Ω typical Low crosstalk: 27dB @ 250 MHz Near-Zero propagation delay: 250ps Switching speed: 9ns Channel On capacitance: 9pF (typical) Operating Range: +3.0V to +3.6V >2kV ESD protection
More informationUser s Manual. Model MS5 Potentiometer Converter (Free Range Type) MODEL AND SUFFIX CODES CAUTIONARY NOTES FOR SAFE USE OF THE PRODUCT
User s Manual Model MS5 Potentiometer Converter (Free Range Type) IM 77J04S05-0E Network Solutions Business Division 2-9-32, Naka-cho Musashino-shi, Tokyo 80-8750 Japan Phone: +8-422-52-779 Facsimile:
More informationTest systems made by SebaKMT. Don t stress over tests! SebaKMT has the right answers: reliability, speed, economy.
Test systems made by SebaKMT Don t stress over tests! SebaKMT has the right answers: reliability, speed, economy. Know how to do it. And what happens next. Test first and save later Connected to the future
More informationTemposonics. Magnetostrictive Linear Position Sensors. EH IO-Link Data Sheet
Temposonics Magnetostrictive Linear Position Sensors EH IO-Link High pressure resistant sensor rod Operating temperature up to +75 C (+167 F) Small & compact Ideal for standard hydraulic cylinders MEASURING
More informationAdvanced Test Equipment Rentals ATEC (2832) Lightning Surge Simulator LSS-F02.
Lightning Surge Simulator Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) LSS-F02 www.noiseken.com Conforming to IEC61000-4-5 ed2 Standard LSS-F02 series A simulator
More informationGeneral Specifications
General Specifications YTA70 Temperature Transmitter The YTA70 is the highly accurate temperature transmitter that accepts Thermocouple, RTD, ohms or DC millivolts inputs and converts it to a to 0 ma DC
More informationSO-QSFP28-4xSFP28-AOCxM
SO-QSFP28-4xSFP28-AOCxM QSFP28 to 4xSFP28, 100G, AOC, xm OVERVIEW The SO-QSFP28-4xSFP28-AOCxM is a parallel active optical cable (AOC) which overcomes the bandwidth limitation of traditional copper cables.
More informationGeneral Specifications
General Specifications MW100-E-1X/X/X/S15 Special Edition 1. MW100/S15 Hardware Specification MW100 Logging type Mainly standalone measurement and distributed remote measurement Style No. S3 Maximum number
More informationBDA Broadband Drop Amplifier
BDA Broadband Drop Amplifier FEATURES 1 GHz Gallium Arsenide Technology 2.5 db Noise Figure Patented Auto Seize FFT F Connector One, Two, or Four Port Versions Two Way Capable LED Power Verification Local
More informationTemposonics. Magnetostrictive Linear Position Sensors. MH-Series Flexible MH Data Sheet
Temposonics Magnetostrictive Linear Position Sensors MH-Series Flexible MH Linear, absolute measurement Easy in-field installation and replacement Stroke lengths from 500 5000 mm Resolution: ±0.2 mm Analog
More informationEconomical Digital Indicators For Process and Electrical Measurement
Economical Digital Indicators For Process and Electrical Measurement DP18 Series Panel Punches Available DP18-P5, 4 to 20 ma input. DP18-EC, thermocouple input visit omega.com/thermocouple for thermocouples.
More informationMAXIMUM LOAD CURRENT 1 A. 3 : 3 VDC (only AC type) 5 : 5 VDC 12 : 12 VDC 24 : 24 VDC A : AC type D : DC type
SOLID STATE RELAY MAXIMUM LOAD CURRENT 1 A FEATURES UL, CSA recognized Extremely small and light weight Size: 10.0 (W) 20.2 (L) 12.8 (H) mm Weight: approximately 5.5g High reliability, long life and maintenance
More informationOperating Instruction
Level and Pressure Operating Instruction VEGASEL 643 6 5 + + 3 5 + + max. min. on VEGASEL 643 5 6 7 8 9 10 11 12 13 14 in out Contents Contents Safety information... 2 1 Product description 1.1 Function
More informationTemposonics. Magnetostrictive Linear Position Sensors. EH Analog Data Sheet
Temposonics Magnetostrictive Linear Position Sensors EH Analog High pressure resistant sensor rod Position measurement with more than one magnet Small & compact Ideal for standard hydraulic cylinders MEASURING
More informationUSER S MANUAL POWER SUPPLY - ISOLATOR - SIGNAL CONVERTER ZSP 41 POWER SUPPLY - ISOLATOR - SIGNAL CONVERTER SIGNAL MULTIPLIER ZSP 41/2
(ENG) DECEMBER 2017 USER S MANUAL POWER SUPPLY - ISOLATOR - SIGNAL CONVERTER ZSP 41 POWER SUPPLY - ISOLATOR - SIGNAL CONVERTER SIGNAL MULTIPLIER ZSP 41/2 ISOLATOR - SIGNAL CONVERTER TYPE SP 11 CURRENT
More informationGeneral Specifications
General Specifications FN510 Field Wireless Multi-Function Module GENERAL This General Specification (GS) describes the specifications for Field Wireless Multi-Function Module. Combined with Field Wireless
More informationMULTIFUNCTION GRAPHICAL UNIT MGU 800
MULTIFUNCTION GRAPHICAL UNIT MGU 800 For display, recording and evaluation of process instruments signals (level, temperature, pressure, etc.) 3.5" TFT display, multi-language menu Variety of possible
More informationQuidoDuplex RS. Set for bi-directional transmission of 4 or 8 two-state signals over RS485 or RS June 2011 w w w. p a p o u c h.
Set for bi-directional transmission of 4 or 8 two-state signals over RS485 or RS232 7. June 2011 w w w. p a p o u c h. c o m Q uidoduplex RS Datasheet Created: 3/16/2006 Last update: 6/7/2011 8:57 AM Number
More informationGeneral Specifications
General Specifications MODEL UT50L Limit Controller GS 5DD-0E Overview The UT50L is an FM approved limit controller that can be configured either as a high limit or as a low limit controller by a user.
More informationPassive Current Transducers for Sinusoidal Alternate Currents From A/0...5 A MCR-SLP-1/5-UI-0(-SW)
Passive Current Transducers for Sinusoidal Alternate Currents From 0... A/0...5 A (-SW) Passive current transducer without power supply Measuring range A and 5 A AC, reconnectable Available with threshold
More informationCompoBus/D-type Digital Controller
CompoBus/D-type Digital Controller Digital Controller for the CompoBus/D and Conforming the DeviceNet Conforms the DeviceNet and connects a Programmable Controller without any programming. High performance
More informationBDA Broadband Drop Amplifier
BDA Broadband Drop Amplifier FEATURES 1 GHz Gallium Arsenide Technology 2.5 db Noise Figure Patented Auto Seize FFT P Series F Connector One, Two, or Four Port Versions Two Way Capable LED Power Verification
More informationConnection targets. Universal sensors and switches, universal output devices
AnyWireASLK System Products Guide ASLKTERMAL [ASLK Small Terminal Block Terminal] BL296 B-08F EURO block type The Products Guide describes individual products. Refer to the Guide as necessary. Function
More informationGeneral Specifications
General Specifications YFGW510 Field Wireless Access Point GS 01W02E01-01EN GENERAL This General Specification(GS) describes the hardware specifications for Field Wireless Access Point and specifications
More informationGeneral Specifications
General pecifications G 33KF- odels, ptical B Bus Repeater odule for km to km (for FV3 /FV ) GRL he ptical B Bus Repeater odule for km to km converts the B bus to an optical signal
More informationSP385A. +3V to +5V RS-232 Line Driver/Receiver. Operates from 3.3V or 5V Power Supply Meets All EIA-232D and V.28 Specifications
SP385A 3V to 5V RS-3 Line Driver/Receiver Operates from 3.3V or 5V Power Supply Meets All EIA-3D and V.8 Specifications at 5V Meets EIA-56 Specifications at 3.3V Two Drivers and Receivers Operates with
More informationCompoNet Gateway Unit for CC-Link
CompoNet Gateway Unit for CC-Link Overview of Gateway Unit...2 CompoNet Settings...2 CompoNet Gateway Unit for CC-Link...3 1 CRT1-series Smart Slave Units 1 Overview of Gateway Unit The CompoNet Gateway
More informationTECHNICAL MANUAL. SERIES AP5202 DC Strain Gage In-Line Amplifier ISO 9001/AS9100
TECHNICAL MANUAL SERIES AP5202 DC Strain Gage In-Line Amplifier ISO 9001/AS9100 Due to the nature of technology, changes are inevitable. For latest technical specifications, see our website. Copyright
More informationGeneral Specifications
General Specifications FN310 Field Wireless Multi-Protocol Module GENERAL This General Specification (GS) describes the specifications for Field Wireless Multi-Protocol Module. Combined with Field Wireless
More informationGeneral Specifications
General pecifications G 33JF- odels, ptical B Bus Repeater odules for km (for -/F) [Release ] GRL he ptical B Bus Repeater odule converts the B bus to an optical signal and transmits
More informationGeneral Specifications
General pecifications G 3QL7-3 odels, ptical us Repeater odule (for ultimode Fiber) GRAL ptical us Repeater odule converts us signal into optical signal, where the bus connects a
More informationDA 30 High Torque Technical Specification
1/17 DA 30 High Torque DA 30-HT-30-5848 2/17 Content 1. General Description... 3 2. Operating Data... 4 3. Performance... 5 4. Materials and Protective Features... 6 5. Dimensions... 6 5.1. Installation
More informationLow Capacitance Transient Voltage Suppressors / ESD Protectors CM QG/D. Features
Low Capacitance Transient Voltage Suppressors / ESD Protectors CM1250-04QG Features Low I/O capacitance at 5pF at 0V In-system ESD protection to ±8kV contact discharge, per the IEC 61000-4-2 international
More informationDatasheet. IndustryAmp PB-800-CN * Applies to Part Number: *This unit has a CobraNet interface installed
PB-800 800-CN Datasheet Applies to Part Number: 590803 IndustryAmp PB-800-CN * *This unit has a CobraNet interface installed User Notice: No part of this document including the software described in it
More informationSTANDBY MODE OFF MODE. POWER HiTESTER. Accurate evaluation of consumption power of electrical products. An Energy Saving Support Tool
An Energy Saving Support Tool POWER HiTESTER Power Measuring Instruments 3332 STANDBY MODE OFF MODE Single-phase, 2-wire type that can accurately measure even standby power Accurate evaluation of consumption
More informationDigital electronic module 4DO DC24V/2A HF (6ES7132-4BD30-0AB0) SIMATIC
Digital electronic module 4DO DC24V/2A HF (6ES7132-4BD30-0AB0) SIMATIC Properties 1 Parameters 2 Diagnostics 3 ET 200S distributed I/O Digital electronic module 4DO DC24V/2A HF (6ES7132-4BD30-0AB0) Manual
More informationA new approach to static electricity countermeasures
Advanced intelligent Sensors NEW ELECTROSTATIC SENSOR EF-SSERIES A new approach to static electricity countermeasures Measurement of surface potentials while a production line is running Phone: 8.894.42
More informationGlass Gas Discharge. RL501 Series. Circuit Protection System ELECTRONICS
ELECTRONICS Glass Gas Discharge RL501 Series Features Approximately zero leaking current before clamping voltage Less decay at on/off state. High capability to withstand repeated lightning strikes. Low
More informationContents Introduction...2 Revision Information...3 Terms and definitions...4 Overview...5 Part A. Layout and Topology of Wireless Devices...
Technical Information TI 01W01A51-12EN Guidelines for Layout and Installation of Field Wireless Devices Contents Introduction...2 Revision Information...3 Terms and definitions...4 Overview...5 Part A.
More informationStabilized Differential Relay SPAD 346. Product Guide
Issued: July 1998 Status: Updated Version: D/21.03.2006 Data subject to change without notice Features Integrated three-phase differential relay, three-phase overcurrent relay and multiconfigurable earth-fault
More informationTemposonics. Magnetostrictive Linear Position Sensors. GB-M / GB-T Analog Data Sheet
Temposonics Magnetostrictive Linear Position Sensors GB-M / GB-T Analog Sensor element and electronics can be changed Flat & compact sensor electronics housing Electrical connection is freely rotatable
More informationTemposonics. Magnetostrictive Linear Position Sensors. GB Analog Data Sheet
Temposonics Magnetostrictive Linear Position Sensors GB Analog High pressure resistant sensor rod High operating temperature up to +100 C (+212 F) Flat & compact ideal for the valve market MEASURING TECHNOLOGY
More informationAXYS IndustryAmp PB-800
AXYS IndustryAmp PB-800 Datasheet by Geert de Vries IndustryAmp PB-800 datasheet User s Notice: No part of this document including the software described in it may be reproduced, transmitted, transcribed,
More informationDA DA 26 Technical Specification. Page 1/27. Volz Servos GmbH & Co. KG servos.com
1/27 DA 26 DA 26 30 5024 2/27 Content 1. General Description... 3 2. Operating Data... 4 3. Performance... 5 4. Command Signal... 6 4.1. PWM Command Interface... 6 4.2. RS 485 Command Signal... 6 4.3.
More informationDPS 100 DPS 100. Gauge- / Differential- / Absolute Pressure Transmitter
Gauge- / Differential- / Absolute Pressure Transmitter for very low starting at 0. mbar inductive sensor for use in industry and laboratory differential ranges from 0... 0. mbar up to 0... 000 mbar The
More informationGeneral Specifications
General Specifications GS 05F01D01E MODEL UM351 Digital Indicator with Alarms with Active Color PV Display General Model UM351 Digital Indicator with Alarms is a precision alarm instrument provided with
More informationResistance Temperature Device Conversion Module
No.SS2-2330-0350 (Rev. 1) SystempaK (Digital/Single Case) Resistance Temperature Device Conversion Module Model J-SRP 90/95 Introduction The Resistance Temperature Device (RTD) Conversion Module (J-SRP)
More information3331, 3332 POWER HiTESTER
99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com An Energy Saving Support Tool 2002 3331, 3332 POWER HiTESTER Power measuring instruments 3332: Single-phase, 2-wire type that
More informationIB IL AI 2/SF. Function. INTERBUS Inline Terminal With Two Analog Input Channels. Data Sheet 5564A
INTERBUS Inline Terminal With Two Analog Input Channels Data Sheet 5564A 06/1999 # # $ " ) This data sheet is intended to be used in conjunction with the INTERBUS Inline System Manual IB IL SYS PRO UM
More informationPHOENIX CONTACT - 03/2007
Inline Function Terminal for Pulse Width Modulation and Frequency Modulation N AUTOMATIONWORX Data Sheet 6920_en_01 1 Description PHOENIX CONTACT - 03/2007 $ ' ) The terminal is designed for use within
More informationRSR30 slim solid state relays
10 AC Load - 2 A / 240 V Optically isolated Low on-state resistance Low input power consumption TTL and CMOS compatible RC networks (V AC) MOSFET output thyristor (V DC) Recognitions, certificates, directives:
More informationma. JUMPFLEX 857 Series. Transducers / Relay and Optocoupler Modules
0 0 ma 0 V...0 ma JUMPFLEX Series Transducers / Relay and Optocoupler Modules JUMPFLEX Series A Complete Product Line is Available, Bringing Each Signal into Shape. The perfect match of housing and electronics
More informationModicon Momentum automation platform 0
Presentation, description Presentation The Momentum analog input bases enable acquisition of various analog values encountered in industrial applications, including: b b b b Standard high level (± 5 V,
More informationSurge Generator for MIL-STD 1275
Surge Generator for MIL-STD 1275 This generator PG1275 is specially designed for the test of the susceptibility to surges and spikes of military 28 Vdc electric circuits. The equipment allows performing
More informationHLG-60H-15 HLG-60H-20 HLG-60H-24 HLG-60H-30 HLG-60H-36 HLG-60H-42 HLG-60H-48 HLG-60H-54 DC VOLTAGE CONSTANT CURRENT REGION Note.
IP65 IP67 SPECIFICATION MODEL -15 - -24-30 -36-42 -48-54 DC VOLTAGE CONSTANT CURRENT REGION Note.4 15V 9 ~ 15V V 12 ~ V 24V 14.4 ~ 24V 30V 18 ~ 30V 36V 21.6 ~ 36V 42V 25.2 ~ 42V 48V 28.8 ~ 48V 54V.4 ~
More informationIP65 IP67. ±5% 0.5Vp-p. 750ms, 80ms / 115VAC at full load 500ms, 80ms / 230VAC at full load
IP65 IP67 SPECIFICATION MODEL 350 700 RATED CURRENT 350mA 700mA CURRENT ACCURACY ±5.0% CONSTANT CURRENT REGION Note.6 100 ~ 0V 50 ~ 100V RATED POWER 70W 70W OUTPUT RIPPLE CURRENT RIPPLE & NOISE ±5% Note.7
More information