Fan-coil intelligent unitary controller

Size: px
Start display at page:

Download "Fan-coil intelligent unitary controller"

Transcription

1 SAUTER EY-modulo 4 PDS en Product Data Sheet EY-RC401 ecos401: Fan-coil intelligent unitary controller How energy efficiency is improved Demand-led control for fan-coil and chilled beams applications using efficient control strategies Areas of application Can be used for fan-coil or chilled beams applications Supports 3-speed fans, 1 electrical re-heater, 2-pipe plants, heating/cooling Features Compact LON fan-coil controller Supports LonMark functional profile #8020 LonMark -certified as per Interoperability Guideline, Version 33 Lower housing can be separated so that terminals and electronics can be installed separately Audio jack plug for rapid access to the LON network LNS plug-in for simple configuration of the functions Technical description 24 V~ power supply 6 universal inputs, can be configured via software 2 universal outputs, can be configured via software 5 digital outputs TP/FT 10, 78 kbps Neuron 3150 processor Products Type EY-RC401F001 Description Fan-coil intelligent unitary controller Technical data Electrical supply Standards, guidelines and directives Power supply 24 V~ (50/60 Hz) ± 15% Type of protection IP 10 (EN 60529) Power consumption: up to 15 VA Protection class I Environmental class 3K3 (IEC 60721) Inputs, outputs CE conformity as per Inputs EMC Directive 2004/108/EC EN Universal 6 EN Can be used as: Digital input Potential-free contact Permitted ambient conditions Analogue input U/I/R Operating temperature 0 50 C Temperature measurement NTC, PT100, PT1000 Transport and storage temperature C Potentiometer R Ambient humidity 0 90% rh no condensation Outputs Digital Triac 10 A 5 Installation Universal 0 10 V 2 Dimensions W x H x D (mm) 145 x 120 x V (on/off) Weight (kg) 035 PWM Additional information Interfaces, communication Fitting instructions; P Protocol LonTalk Material declaration MD Transceiver FT-X1 TP/FT-10, 78 Kbps Dimension drawing M11424 Connection LON audio jack mono 1/8" M11425 EnOcean (F002) 5 available channels Wiring diagram A10601 Radio frequency 8683 MHz Accessories Type EY-RU481F001 EY-RU481F002 EY-RU481F003 Description Sensor Sensor, occupancy Sensor, occupancy, setpoint wwwsauter-controlscom 1/5

2 General functioning of the room automation station The ecos401 intelligent unitary controller is a microprocessorassisted, configurable controller used to control and regulate a varied range of HVAC applications on the basis of LON technology The ecos401 intelligent unitary controller uses the LonTalk communication protocol and is LonMark -certified if the sensor profile (number 1) is used for the relevant input objects and if the actuator profile (number 3) is used for the relevant output objects The ecos401 intelligent unitary controller supports LonMark profile #8020 The integrated operating programme can be programmed freely with the help of a plug-in; it reads in the hardware and software addresses, processes the user programme, updates the outputs and handles the necessary communication with other stations in the network or with the management level The user program can be loaded from any point in the LON network using SAUTER CASE LON Engine The plug-ins can be used to parameterize the controllers with the SAUTER CASE LON Engine network management tool or via any LNS-based software, according to choice Engineering notes Installation and wiring The ecos401 intelligent unitary controller can be fitted in an MCC using a top-hat rail (EN 50022) Wall-mounting is possible, using the fitting holes in the lower housing It is possible to separate the upper and lower sections of the housing in order to install and connect the automation station The plant devices are connected via screw terminals The following conditions must be met: Cross-section conductors: LON network: of min 082 mm 2 (AWG 18), max 2 mm 2(AWG 13), compliant with standards and national installation regulations min 065 mm 2 (AWG 22), twisted and unscreened Suitable network terminations (terminators) must be used for different network topologies Failure to comply with the specified requirements may cause transmission errors between the controllers The use of different cable cross-sections in one network section is not permitted Detailed guidelines on planning and installing twisted-pair LonWorks networks have been published by the Echolon Corporation Connections: LON network: 2 (jack plug, mono, 1/8" / 35 mm) Earth terminals: 9 I/O terminals: 13 LS-MM terminals: 24 V ~ Hardware: The ecos401 intelligent unitary controller comprises: Processor Memory Communication Channel Status indicators Neuron 3150 ; 8 bit; 10 MHz Non-volatile 64 kb flash memory (APB and programme application) LonTalk protocol TP/FT-10; 78 kbit/s Green LED: Power supply status and LON-TX Orange LED: Operation and LON-RX Description of inputs and outputs The ecos401 intelligent unitary controller has 6 universal inputs and 2 universal outputs 5 Triac outputs are also available in each case All the inputs and outputs must be configured via software The input resolution is 16 bits and the output resolution is 10 bits The inputs and outputs may be used as follows: Input Temperature sensor: Potentiometer: Current: Voltage: Digital: Pulse: NTC, Pt 10 k, 100 k 0 20 ma (4 20 ma) 0 10 V Potential-free contact Potential-free contact Output Voltage 0 10 V= Digital: 0 12 V=, (I/O) PWM The sampling period for the inputs is 1 s if they are configured as voltage, potentiometer or temperature inputs, and 500 ms for configuration as digital inputs The UIx inputs can take a maximum load of 24 V Technical specifications of inputs and outputs Temperature measurement (NTC, Pt) The Pt1000 sensors are connected using the two-wire method between one of the input terminals for a universal input (UI01 UI06) and an earth terminal In case of an NTC/Pt connection, the inputs do not require calibration and can be used directly The connected sensor type and the desired offset input are chosen in the software NTC type 2, 10 k Accuracy: ± 05 C NTC type 3, 10 k Accuracy: ± 05 C Circuit Period duration Value Short-circuit/ override *) < 5 s > 5 s > 15 s Override = on Override = off Input = Open PT1000, 1 k Accuracy: ±1 C PT100, 100 k Range: C Accuracy: ±1 C Circuit Period duration Value Short-circuit/ override *) < 5 s > 5 s > 15 s Override = on Override = off Input = Open *) If the input is short-circuited, this may be interpreted as an override, ie the relevant control loop is switched from "unoccupied" status to the "occupied/override" operating mode Potentiometer measurement (Pot) It is possible to use the input in combination with a potentiometer if a 10 k or 100 k resistance is used For configuration purposes, the resistance value can be limited and scaled to any desired value range in C A potentiometer is connected between an input terminal of a universal input (UI01 UI06) and the associated earth terminal The measurement accuracy is ± 05% 2/5 wwwsauter-controlscom

3 Current measurement (I) The current to be measured is connected to the input terminals of the universal inputs (UI01 UI06) between UIx and earth The signal must be potential-free In order to use the current input on the ecos401 intelligent unitary controller, either a supply of current to the sensor or a parallel input-sensor supply is required An external voltage source or the integrated 15 V= can be used for this purpose A 249 resistance must also be connected in parallel with the input The input is defined as a 4 20 ma input by default To adapt the input to 4 20 ma, the minimum value must be configured as 4 ma in the software Voltage measurement (U) The universal inputs (UI01 UI06) are used to measure voltage The voltage input has a range of 0 10 V The connection is made to an input and the associated earth terminal The voltage signal must be potential-free The input can be adapted to different ranges via software Parameters "min", "max" or "offset" are available for this purpose Digital inputs (DI) All universal inputs (UI01 UI06) can be used as digital inputs and must be connected to earth Type of inputs: Potential-free contacts, connected to earth Opto-coupler Transistor (open collector) Digital information is connected between the input terminals (UI01 UI06) and earth The station applies a voltage of approx 13 V to the terminal In normal cases (NORMAL) this corresponds to INACTIVE (bit=0) for an open contact When a contact is closed it is ACTIVE (bit=1) and 0 V is applied, whereby the current flow equates to approx 1 ma For each input, it is possible to define the "on" and "off" values individually, as well as the direction of operation (normal or reverse) Universal outputs The universal outputs (UO06 and UO07) can be configured as voltage outputs, via the software The output voltage is measured between the relevant output terminal and an earth terminal (UOx, Com) Type of output 0 10 V= max 60 ma to earth Digital output (DO) Alternatively, the universal outputs (UO06 and UO07) can be configured as digital outputs A discrete output signal is issued: 0 V= for OFF and 12 V= for ON If a relay is triggered via the universal output, a diode (1N400x family) must be connected to the connection terminals in parallel This protects the output against voltage peaks when the relay cuts out If the universal outputs are configured as PWM outputs, the period duration can be set between 2 s and 15 min The period duration can be set between 0 and 100% of the "on" duration Loading capacity of the output: Max 20 ma at 12 V= max load 600 The output is fitted with a self-resetting fuse Maximum power load: 60 ma at 60 C 100 ma at 100 C Parameterisation of the intelligent unitary controllers variables The controller software supports structured SNVTs and UNVTs of 1 and 2 bytes in length 16 NVIs and 20 NVOs (with changeable types and lengths) are available User programme Simple configuration of all device parameters, including inputs, outputs, ventilator and fan settings, and setpoints for heating and cooling It is also possible to parameterise additional integrated functions such as optimal start/stop procedures, load shedding, frost protection and slave operating mode Triac outputs (DO) 5 digital (UO01 UO05) Triac max 10 A at 24 V~ External power supply with external fuse (fast-blow 4 A fuse with high cut-out power) One earth per output wwwsauter-controlscom 3/5

4 Functional profile ecos401 Node Object Type #0 ecos401 Fan Coil Object Type #8020 nvirequest SNVT_obj_request nvostatus SNVT_obj_status nvispacetemp nvoheatoutput Optional nvofiledirectory SNVT_address nvisetpoint SNVT_ppm_f nvocooloutput nvofanspeed Location (optional) Device Major Version (optional) Device Minor Version (optional) nvifanspeedcmd nviapplicmode SNVT_hvac_mode Optional nvoterminalload nvodischairtemp Manufacturer nvofcstate SNVT_state_64 nvofcalarm SNVT_state_64 nvisetptoffset nviwatertemp nvidischairtemp nvospacetemp nvoeffectsetpt nvooccstate SNVT_occupancy Maximum Send Time nvienergyholdoff nvounitstatus SNVT_hvac_status Occ Temperature Set Points (mandatory) Maximum Send Time (mandatory) Minimum Send Time (optional) ecos401 Hardware Input Object Type #1 Offset (optional) Maximum Range (optional) Minimum Range (optional) Minimum Send Delta (optional) Maximum Send Time (optional) Minimum Send Time (optional) Override Value (optional) nvohwinputx (x=1-6) SNVT_xxx nvishedding nvihotwater nvislave nvioutdoortemp nviocccmd SNVT_xxx nvioccmancmd SNVT_occupancy Manufacturer nvowatertemp nvosetptoffset nvoctrloutput1 nvoctrloutput7 Object Major Version Object Minor Version Input Signal Conditioning Hardware Properties Translation Table Default Value Please see the manual for details Plug-In for configuration provided ecos401 Hardware Output Object Type #3 nviextcmdoutputx (x=1-7) Maximum Receive Time (optional) Override Value (optional) Object Major Version Object Minor Version Output Signal Conditioning PWM Period Translation Table Default Value 4/5 wwwsauter-controlscom

5 Dimension drawing 144,8 50,8 108,0 M11424 M ,4 57,2 Wiring diagram x-x Fuse + L N 2-Line Main x-x Fuse AXT111F VDC Relay Uxx0-10V Ext Trafo 230 / 24 V Ls MM 24 V modu430 Power DO1 1 DO2 2 Inputs (Universal) DO3 3 Outputs (Triac) DO4 4 DO5 5 UO6 6-7 UO7 Outputs (Universal) O1 O2 O3 O4 O5 O6 O7 Service TX RX UI UI 2 UI UI 4 UI UI 6 LON1 LON A NTC 10k Pt100 Platin 1k -RTD Digitaler Eingang Digital Input Entrée digitales 010 V 10 k 020 ma Fr Sauter Ltd Im Surinam 55 CH-4016 Basle Tel Fax wwwsauter-controlscom info@sauter-controlscom wwwsauter-controlscom /5 02 Printed in Switzerland

DDC volume flow controller

DDC volume flow controller SAUTER EY-modulo 4 PDS 94.120 en Product Data Sheet ecos415: DCC volume flow controller How energy efficiency is improved Demand-led control for air volume flows using efficient control strategies. Battery-free

More information

modu420: Automation station

modu420: Automation station SAUTER EY-modulo 4 PDS 92.285 en Product Data Sheet EY-AS420 modu420: Automation station How energy efficiency is improved Integrated pulse counter to measure and optimise energy consumption. Integrated

More information

ECP-103 Series. ECP-103 Series. 10-Point Free Programmable Controller. Applications. Features

ECP-103 Series. ECP-103 Series. 10-Point Free Programmable Controller. Applications. Features ECP-103 Series 10-Point Free Programmable Controller Applications Control of terminal units such as VAV, FCU, UV and HPU as well as control for chilled ceiling applications. Control of many other types

More information

EY-EM 527: Remote I/O module, ecolink527

EY-EM 527: Remote I/O module, ecolink527 Product data sheet 94.078 EY-EM 527: Remote I/O module, ecolink527 How energy efficiency is improved Regulation, control, monitoring and optimisation of operational systems, e.g. room automation or HVAC

More information

EY-EM 522, 523: Remote I/O module, ecolink522, 523

EY-EM 522, 523: Remote I/O module, ecolink522, 523 Product data sheet 94.077 EY-EM 522, 523: Remote I/O module, ecolink522, 523 How energy efficiency is improved Regulation, control, monitoring and optimisation of operational systems, e.g. room automation

More information

ECL-VAV-N. Features & Benefits

ECL-VAV-N. Features & Benefits D a t a s h e e t ECL-VAV-N Overview The ECL-VAV-N controller is a microprocessorbased programmable variable air volume (VAV) controller designed to control any variable air volume box. This controller

More information

ECP-400 Series. ECP-400 Series. 24-Point Free Programmable Controller. Applications. Features

ECP-400 Series. ECP-400 Series. 24-Point Free Programmable Controller. Applications. Features ECP-400 Series 24-Point Free Programmable Controller Applications Control of equipment such as: roof top units, multistage air handling units, chillers, boilers, pumps, cooling towers, lighting systems,

More information

ECB-103 BACnet B-ASC 10-Point Programmable Controllers

ECB-103 BACnet B-ASC 10-Point Programmable Controllers D a t a s h e e t BACnet B-ASC 10-Point Programmable Controllers Overview The is a microprocessor-based programmable controller designed to control terminal units such as fan coil unit, heat pump unit,

More information

EYL225: nova225, Compact automation station

EYL225: nova225, Compact automation station SAUTER EY3600 PDS 92.525 en Product Data Sheet EYL225 EYL225: nova225, Compact automation station The nova225 compact automation station can be connected with various outlying units, so-called field modules.

More information

NRT 105: Electronic fan-coil controller, equiflex

NRT 105: Electronic fan-coil controller, equiflex Product data sheet 4.04 R 105: Electronic fan-coil controller, equiflex How energy efficiency is improved ECO Meter for displaying the current energy consumption and digital input for the change-over between

More information

LONMARK Certified 14-Point Programmable Controller. Overview

LONMARK Certified 14-Point Programmable Controller. Overview LONMARK Certified 14-Point Programmable Controller Applications Meets the requirements of the following applications: Rooftop Units Fan Coil Units Heat Pump Units Unit Ventilators Small Air Handling Units

More information

LONMARK Certified 10-Point Programmable Controller. Overview

LONMARK Certified 10-Point Programmable Controller. Overview LONMARK Certified 10-Point Programmable Controller Applications Meets the requirements of the following applications: Fan Coil Units Heat Pump Units Unit Ventilators Chilled Ceilings Improves energy efficiency

More information

Excel 10 W7763C,D,E CHILLED CEILING CONTROLLERS LNS PLUG-INS

Excel 10 W7763C,D,E CHILLED CEILING CONTROLLERS LNS PLUG-INS Excel W7763C,D,E CHILLED CEILING CONTROLLERS LNS PLUG-INS HONEYWELL EXCEL 5 OPEN SYSTEM USER GUIDE CONTENTS Introduction... Description of Devices... Products Covered... Organization of Manual... Applicable

More information

NRT 300: Electronic air-conditioning controller, heating/cooling, equiflex

NRT 300: Electronic air-conditioning controller, heating/cooling, equiflex roduct data sheet 43.019 NR 300: Electronic air-conditioning controller, heating/cooling, equiflex ow energy efficiency is improved ey directly on device for individual changeover between presence and

More information

SRC-110 Series Zone Controllers with Modbus RTU

SRC-110 Series Zone Controllers with Modbus RTU Product sheet CT2.142 Type SRC-110-MOD SRC-110 Series Zone Controllers with Modbus RTU The SRC-110 series controllers have been designed for zone heating and cooling control. The controllers have 3 analogue

More information

Lonbox PIO4014 Users Manual

Lonbox PIO4014 Users Manual PROLON CONTROL SYSTEMS Herstedvesterstraede 56 DK-2620 Albertslund Denmark Tlf.: (+45) 43668060 Fax.: (+45) 43668061 e-mail: info@prolon.dk Internet: www.prolon.dk Lonbox PIO4014 Users Manual PIO4014 energy

More information

EYK220: nova220, Compact automation station with BACnet interface

EYK220: nova220, Compact automation station with BACnet interface SAUTER EY3600 PDS 92.450 en Product Data Sheet EYK220 EYK220: nova220, Compact automation station with BACnet interface This EYK220 is the compact nova220 units of the EY3600 system family equipped with

More information

Control solutions Biofloor

Control solutions Biofloor MR24 Central radio controller 24V Connect COMAP offers the Connect control system as part of its underfloor heating and cooling solution. Composed of a central radio control module (MR24), wireless digital

More information

Brief description. VAV-Compact LON en-gb Changes reserved 1. Application. Pressure measurement

Brief description.   VAV-Compact LON en-gb Changes reserved 1. Application. Pressure measurement Product information VAV-Compact LON A pressure sensor, digital VAV controller and damper actuator all in one, providing a compact solution with a communications capability for pressure-independent VAV

More information

XIOC technology and networking modules

XIOC technology and networking modules / XIO XIO digitale and analog input/output modules XIO technology and networking modules XIO the compact I/O and much more XIO are local expansion modules for direct connection to all Xontrol controllers.

More information

Viconics VT76x7 Series Rooftop Unit Controllers Engineering Guide Specification

Viconics VT76x7 Series Rooftop Unit Controllers Engineering Guide Specification Viconics VT76x7 Series Rooftop Unit Controllers Engineering Guide Specification General The VT76x7 series is designed for single-stage and multi-stage control of heating/cooling equipment such as rooftop

More information

CONTA-ELECTRONICS. Converter Units

CONTA-ELECTRONICS. Converter Units CONTA-ELECTRONICS Whether for manufacturing, electrical machine and plant instrumentation, control engineering, power distribution, building automation, or process engineering it is always important to

More information

DUAL 4-20 MA NETWORK BRIDGE. Voltage. Regulator. Neuron CPU. Ohm Sense Resistor. Model 1400A Block

DUAL 4-20 MA NETWORK BRIDGE. Voltage. Regulator. Neuron CPU. Ohm Sense Resistor. Model 1400A Block NEUROLOGIC RESEARCH CORPORATION MODEL 1400A DUAL 4-20 MA NETWORK BRIDGE Instantly integrate any standard sensor into the LONWORKS digital network. Supports loop and self powered sensors. Electronics are

More information

Power amplifier for thermic valve actuators

Power amplifier for thermic valve actuators 9 Power amplifier for thermic valve actuators For controllers with an AC V output signal The power amplifier is used to allow the connection of additional valve actuators to controllers with an AC V output

More information

LON I/O Module DR-N MCU4-AC Art. no.: MTN881811

LON I/O Module DR-N MCU4-AC Art. no.: MTN881811 Art. no.: MTN881811 User Manual LON I/O Module DR-N MCU4-AC Art. no.: MTN881811 Directory Directory... 1 1.... 2 2. Function... 2 3. Mounting... 3 4. Remarks... 3 5. Technical Data... 4 6. Application

More information

Room Temperature Controllers. for heating and cooling systems

Room Temperature Controllers. for heating and cooling systems 3 041 RCU10 RCU101 Room Temperature Controllers for heating and cooling systems RCU10 Choice of two-position or modulating PI control ON / OFF or PWM outputs for heating and cooling Operating modes: normal

More information

43.019/1. NRT 300: Electronic controller for air-conditioning (heating/cooling) Sauter Components

43.019/1. NRT 300: Electronic controller for air-conditioning (heating/cooling) Sauter Components 43.09/ NR 300: Electronic controller for air-conditioning (heating/cooling) For fixed-value control (I control, continuous) in air-conditioning systems, for residential and business premises. Used with

More information

PolyGard Digital Transmitter DGC DT-02

PolyGard Digital Transmitter DGC DT-02 PolyGard Digital Transmitter DGC DT-02 Description LON interoperable digital gas transmitter to monitor toxic and combustible gases and vapors in the ambient air. The complete monitoring and alarm tripping

More information

Room Temperature Controllers. for heating and cooling systems

Room Temperature Controllers. for heating and cooling systems 3 048 RCU15 Room Temperature Controllers for heating and cooling systems RCU15 Choice of two-position or modulating PI control ON / OFF or PWM outputs for heating and cooling Control depending on room-

More information

Excel 10 W7761A Remote Input/Output Device

Excel 10 W7761A Remote Input/Output Device Excel 0 W776A Remote Input/Output Device INSTALLATION INSTRUCTIONS PRODUCT DESCRIPTION The W776A Remote Input/Output (RIO) Device is a Free Topology Transceiver (FTT) LonMark compliant device in the Excel

More information

Intelligent Compact Controller

Intelligent Compact Controller TCY-T0121 Intelligent Compact Controller Features Temperature control for 2-pipe, 4-pipe HVAC systems. Temperature range from 40 to 140 C. 1 independent PI and On/Off control loop to control temperature.

More information

LonWorks Integration Instructions

LonWorks Integration Instructions LonWorks Communicating Room Controllers LonWorks Integration Instructions PIR Ready SE76x7 Series Programmable & Non-Programmable Controllers for Commercial HVAC Applications CONTENTS PID History Revision

More information

Electronic Step Controller

Electronic Step Controller 4 915 Electronic Step Controller, Adjustable switch-on delay (typically used to prevent current surges on startup and after a power failure) Adjustable switch-on points Adjustable switching differential

More information

92.450/1. EYK 220: nova220, Compact automation station with BACnet interface. Sauter Systems

92.450/1. EYK 220: nova220, Compact automation station with BACnet interface. Sauter Systems 92.450/1 EYK 220: nova220, Compact automation station with BACnet interface This EYK 220 is the compact nova220 units of the EY3600 system family equipped with a BACnet communication card (EYK 300). This

More information

Zone controller TAC Xenta 102

Zone controller TAC Xenta 102 Zone controller TAC Xenta 102 Handbook TAC improves indoor climate and reduces operating costs. Air flow Heating Changeover via network variable Cooling Cooling demand 0-004-7516-1 (GB), 1999-08-18 Foreword

More information

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency echnical data sheet GR24A--R Communicative Retrofit rotary actuator for rotary valves and butterfly valves Nominal torque 40 Nm Nominal voltage AC/DC 24 V Control Modulating DC (0)2...10 V Variable Position

More information

FTT-10A Free Topology Twisted Pair Transceiver Model 50051

FTT-10A Free Topology Twisted Pair Transceiver Model 50051 FTT-10A Free Topology Twisted Pair Transceiver Model 50051 Description The FTT-10A Free Topology Twisted Pair Transceiver provides a simple, cost-effective method of adding a LONWORKS transceiver to any

More information

Gateway EnOcean/LonWorks

Gateway EnOcean/LonWorks s 1 661 1661P01, 1661P02 DESIGO RXC Gateway EnOcean/LonWorks For use with: DESIGO RXC Devices / systems with LONWORKS communication RXZ95.1/LON Wireless receiver with LONWORKS interface FTT10A Evaluation

More information

Room Temperature Controllers. for heating and cooling systems

Room Temperature Controllers. for heating and cooling systems 3 041 RCU10 RCU10.1 Room Temperature Controllers for heating and cooling systems RCU10... Choice of two-position or modulating PI control ON / OFF or PWM outputs for heating and cooling Operating modes:

More information

Software Description SRCN_HWL_9_1_03 for SRC 04 FTT and SRC 65 FTT

Software Description SRCN_HWL_9_1_03 for SRC 04 FTT and SRC 65 FTT Software Description SRCN_HWL_9_1_03 for SRC 04 FTT and SRC 65 FTT 1 Overview The application enables the receipt and evaluation of max. nine EnOcean wireless sensors. The following sensor types are supported:

More information

Analogue temperature controllers

Analogue temperature controllers Analogue temperature controllers CT8A Input by J-K thermo-couple or by thermo-resistance Pt 00 (-wire) regulation modes : ON/OFF or proportional derivative selected by wiring Relay output Specifications

More information

Technical Information itemp TMT180

Technical Information itemp TMT180 TI00088R/09/EN/14.16 71315611 Technical Information itemp TMT180 Temperature head transmitter for resistance thermometers Pt100 Configurable using a PC, for installation in a terminal head, form B Application

More information

VFSC9 ELECTRONIC SPEED CONTROLLER. Mounting and operating instructions

VFSC9 ELECTRONIC SPEED CONTROLLER. Mounting and operating instructions ELECTRONIC SPEED CONTROLLER Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 5 WIRING

More information

Room Temperature Controllers. for heating and cooling systems

Room Temperature Controllers. for heating and cooling systems 3 048 RCU15 Room Temperature Controllers for heating and cooling systems RCU15 Choice of two-position or modulating PI control ON / OFF or PWM outputs for heating and cooling Control depending on room-

More information

..F24ALON. Spring return actuators for LONWORKS, AC/DC 24 V. Node object #0. Damper actuator object #8110. Open Loop Sensor Object #1

..F24ALON. Spring return actuators for LONWORKS, AC/DC 24 V. Node object #0. Damper actuator object #8110. Open Loop Sensor Object #1 ..F4A Spring return actuators for WORKS, AC/DC 4 V Functional Profile as per MARK he -capable rotary actuator is certified by MARK. Die following actuator functions are made available via the WORKS network

More information

TEC226x-3 and TEC220x-3 Series LONWORKS Network Staged Thermostats

TEC226x-3 and TEC220x-3 Series LONWORKS Network Staged Thermostats TEC226x-3 and TEC220x-3 Series LONWORKS Network Staged Thermostats Technical Bulletin Code No. LIT-12011197 Issued September 8, 2006 Network Variables (NVs) and Configuration Parameters (CPs) List.............

More information

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals Accessories High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals WIKA data sheet AC 80.03 Applications Machine building

More information

UniStream Uni-I/O Modules

UniStream Uni-I/O Modules UniStream Uni-I/O Modules Technical Specifications UIS-WCB1 This guide provides specifications for Unitronics Uni-I/O Wide module UIS-WCB1. This module comprises: 10 Digital inputs, 24VDC, sink/source,

More information

Electro Controls. Input-Output Modules WattsIndustries.co.uk

Electro Controls. Input-Output Modules WattsIndustries.co.uk Electro Controls Input-Output Modules - 2017 WattsIndustries.co.uk Input-Output Modules Section 08 B.M.S INPUT - OUTPUT MODULES SINGLE AND ADJUSTABLE RELAY ESRM.. Volt free contacts DIN RAIL mounted relay

More information

R7420B. MicroniK 100 HONEYWELL TEMPERATURE CONTROLLER PRODUCT DATA GENERAL FEATURES

R7420B. MicroniK 100 HONEYWELL TEMPERATURE CONTROLLER PRODUCT DATA GENERAL FEATURES HONEYWELL MicroniK 1 R742B TEMPERATURE CONTROLLER GENERAL PRODUCT DATA The temperature controller R742B uses direct digital control technology to provide a more accurate and efficient operation of heating,

More information

FX10 Standard Programmable Electronic controller for HVAC and refrigeration applications. Features and Benefits

FX10 Standard Programmable Electronic controller for HVAC and refrigeration applications. Features and Benefits Slim Object Platform Catalogue Product Bulletin FX10 Issue Date 0 00 FX10 Standard Programmable Electronic controller for HVAC and refrigeration applications I ntroduction The FX10 is a high performance,

More information

A local 3.5 mm network jack allows a convenient way to connect an installation or diagnostic tool to the network without disconnecting any wires.

A local 3.5 mm network jack allows a convenient way to connect an installation or diagnostic tool to the network without disconnecting any wires. FEATURES - Extends wiring distance of FTT-10 LonWorks Networks. - Up to 5 repeaters can be daisy chained together to create a multi-segment repeater of up to 10 channels. - Low cost alternative to routers

More information

The universal input/output device is a DIN rail mounted device. It is connected to the EIB via a bus connecting terminal.

The universal input/output device is a DIN rail mounted device. It is connected to the EIB via a bus connecting terminal. , GH Q631 0026 R0111 SK 0097 B97 The universal input/output device is a DIN rail mounted device. It is connected to the EIB via a bus connecting terminal. The device has 32 freely programmable inputs/outputs,

More information

Jacket heater, etc Mounting bracket for Pipe wrapping. (Optional) Temperature sensor. Output (To heater) (Optional)

Jacket heater, etc Mounting bracket for Pipe wrapping. (Optional) Temperature sensor. Output (To heater) (Optional) Temperature Controller with Built-in SSR SB SB General Description SB is a channel temperature controller with Built-in SSR (Solid state relay) designed for flexible heating solutions such as heat trace

More information

UniStream Built-in. Technical Specifications US7-B5-RA28, US7-B10-RA28 US7-B5-TA30, US7-B10-TA30

UniStream Built-in. Technical Specifications US7-B5-RA28, US7-B10-RA28 US7-B5-TA30, US7-B10-TA30 UniStream Built-in Technical Specifications US5-B5-RA28, US5-B10-RA28 US5-B5-TA30, US5-B10-TA30 US7-B5-RA28, US7-B10-RA28 US7-B5-TA30, US7-B10-TA30 Unitronics UniStream Built-in series are PLC+HMI All-in-One

More information

Gateway EnOcean/LonWorks

Gateway EnOcean/LonWorks s 1 661 1661P01, 1661P02 DESIGO RXC Gateway EnOcean/LonWorks For use with: DESIGO RXC Devices / systems with LONWORKS communication RXZ95.1/LON Wireless receiver with LONWORKS interface FTT10A Evaluation

More information

Wireless multizone receiver RDE-MZ6

Wireless multizone receiver RDE-MZ6 s 1 428 Wireless multizone receiver RDE-MZ6 for floor heating / zone heating systems Mains-powered RDE-MZ6 multizone wireless receiver (AC 230 V) DIN rail mounting 2-position control with On/Off output

More information

11 VA Connection Cable 1 m, 4 x 0.75 mm 2 Functional data Factory settings Variable Setting Torque (nominal torque) Motor Spring return

11 VA Connection Cable 1 m, 4 x 0.75 mm 2 Functional data Factory settings Variable Setting Torque (nominal torque) Motor Spring return echnical data sheet SF24A- Communicative spring return actuator with emergency function for adjusting air dampers in ventilation and air conditioning systems in buildings For air dampers up to approx.

More information

Compact room automation stations, BACnet MS/TP, AC 24 V

Compact room automation stations, BACnet MS/TP, AC 24 V Desigo Room Automation Compact room automation stations, BACnet MS/TP, AC 24 V DXR2.M11.., DXR2.M12P.., DXR2.M12PX.., DXR2.M18.. For building with increased demands placed on functionality and flexibility

More information

DESCRIPTION MODEL 1450 NOTE

DESCRIPTION MODEL 1450 NOTE - Instantly integrate any standard 4-20 ma sensor into the LonWorks digital network. - Supports loop and self powered devices. - Digitally calibrated for accuracy and custom inputs. - Very stable 15 ppm

More information

US2, US4, US6 Electronic step controllers

US2, US4, US6 Electronic step controllers 4 98 US, US4, Electronic step controllers The electronic step controllers are used in linear mode to switch devices (pumps, compressors, humidifiers and fans etc.) on and off in stages. Switch-on time

More information

Supercal 531 Multi function Integrator that lives up to Your highest expectations

Supercal 531 Multi function Integrator that lives up to Your highest expectations n Thermal Energy n Flow Metering n Supercal 531 Multi function Integrator that lives up to Your highest expectations Supercal 531 Multi functional integrator with unlimited options The Supercal 531 convinces

More information

Valve Island with Electronic I/O

Valve Island with Electronic I/O Screw in Temperature /Switch with display for ON/OFF Control Indication, monitoring, transmission and ON/OFF control in one device Extra large display Menu guided parametrisation Complete communication

More information

RE17RCMU off-delay timing relay - 1 s..100 h V AC - 1 OC

RE17RCMU off-delay timing relay - 1 s..100 h V AC - 1 OC Characteristics off-delay timing relay - 1 s..100 h - 24..240 V AC - 1 OC Main Range of product Product or component type Discrete output type Width Device short name Time delay type Time delay range Nominal

More information

R7L-YV2. DC VOLTAGE OUTPUT MODULE, 2 points MODEL BEFORE USE... POINTS OF CAUTION COMPONENT IDENTIFICATION INSTRUCTION MANUAL R7L-YV2

R7L-YV2. DC VOLTAGE OUTPUT MODULE, 2 points MODEL BEFORE USE... POINTS OF CAUTION COMPONENT IDENTIFICATION INSTRUCTION MANUAL R7L-YV2 INSTRUCTION MANUAL DC VOLTAGE OUTPUT MODULE, 2 points MODEL R7L-YV2 BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below. If you

More information

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC Characteristics on-delay timing relay - 1 s..100 h - 24..240 V AC - 1 OC Main Range of product Product or component type Discrete output type Width Device short name Time delay type Time delay range Nominal

More information

SMX Transceivers Models 77010, 77030, 77040, 77050, and 77162

SMX Transceivers Models 77010, 77030, 77040, 77050, and 77162 SMX Transceivers Models 77010, 77030, 77040, 77050, and 77162 Compatible with the LONWORKS SMX interface standard Built-in transceiver ID output supports automatic configuration of communications parameters

More information

ECL-VAV Series Preloaded Applications. User Guide

ECL-VAV Series Preloaded Applications. User Guide ECL-VAV Series Preloaded Applications User Guide Document Revision History: Version 1.0 Initial Release March 2012 Version 1.1 Added the Occupancy Sensor Hold Time option in the system configuration ECL-VAV

More information

Electrical data Nominal voltage AC 230 V Nominal voltage frequency

Electrical data Nominal voltage AC 230 V Nominal voltage frequency echnical data sheet SY3-30-MP- Communicative rotary actuator for butterfly valves ominal torque 50 m ominal voltage Control modulating, communicative DC (0)...0 V Variable Position feedback DC...0 V Variable

More information

SEM1600T RTD/TC/SLIDE WIRE SIGNAL CONDITIONER

SEM1600T RTD/TC/SLIDE WIRE SIGNAL CONDITIONER RTD, THERMOCOUPLE, THERMISTOR (BMS SENSORS), SLIDE WIRE, mv AND RESISTANCE INPUTS ma, VOLTAGE OR BIPOLAR VOLTAGE OUTPUT SENSOR OFFSET (TEMPERATURE) 22 SEGMENT USER LINEARISATION (PROCESS) CONFIGURATION

More information

SRC-200 Series Climate Controllers with BACnet MS/TP

SRC-200 Series Climate Controllers with BACnet MS/TP Product sheet CT2.151 Type SC-200-BAC SC-200 Series Climate Controllers with BACnet MS/TP The SC-200 series controllers have been designed for climate control in room spaces. The controllers have up to

More information

92.460/1. EYK 230: nova230, Compact BACnet universal automation station. Sauter Systems

92.460/1. EYK 230: nova230, Compact BACnet universal automation station. Sauter Systems 92.460/1 EYK 230: nova230, Compact BACnet universal automation station The EYK 230 is the compact nova230 unit from the EY3600 family of systems with interface functions, equipped with a BACnet communication

More information

Modbus communication module for TCX2: AEX-MOD

Modbus communication module for TCX2: AEX-MOD Modbus communication module for TCX2: Communication Specification TCX2 is factory installed in TCX2 series controllers with -MOD suffix, and is also available separately upon request for customer installation

More information

Room Temperature Controllers. for heating and cooling systems

Room Temperature Controllers. for heating and cooling systems 3 041 RCU10 RCU10.1 Room Temperature Controllers for heating and cooling systems RCU10... Choice of two-position or modulating PI control ON / OFF or PWM outputs for heating and cooling Operating modes:

More information

Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version

Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version Electrical temperature measurement Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version WIKA data sheet TE 15.01 Applications Process industry Machine building

More information

Functional description "BIU-2ILT"

Functional description BIU-2ILT Cécile PAULME AEG Functional description "BIU-2ILT" TABLE OF CONTENTS 1. INTRODUCTION 3 2. ELECTRONIC PRODUCT FORM 4 2.1 Product description...4 2.2 Physical installation...5 2.3 Technical specifications...6

More information

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency echnical data sheet LH24A-00 Communicative linear actuator adjusting dampers and slide valves in technical building installations Air damper size up to approx. m² Actuating force 50 N Nominal voltage AC/DC

More information

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals Accessories Highquality digital indicator for panel mounting Model DI35M, with multifunction input Model DI35D, with two inputs for standard signals WIKA data sheet AC 80.03 Applications Machine building

More information

High Performance Process & Temperature Controllers

High Performance Process & Temperature Controllers C22 C62 C82 C83 High Performance Process & Temperature Controllers C72 C42 R22 01. Multi Color LCD Display 02. High Accuracy 18 Bit A-D Input and 15 Bit D-A Output 03. 200 msec Sampling Rate 04. True Universal

More information

SRC-110 Series Zone Controllers. BACnet MS/TP. Product sheet CT2.143 SRC-110-BAC

SRC-110 Series Zone Controllers. BACnet MS/TP. Product sheet CT2.143 SRC-110-BAC Product sheet CT2.143 Type SC-110-BAC SC-110 Series Zone Controllers with BACnet MS/TP The SC-110 series controllers have been designed for zone heating and cooling control. The controllers have 3 analogue

More information

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency echnical data sheet LR24A-KNX Communicative rotary actuator for ball valves Nominal torque 5 Nm Nominal voltage AC/DC 24 V Control modulating Conversion of sensor signals Communication via KNX (S-Mode)

More information

Overview of types. Technical data

Overview of types. Technical data echnical data sheet SHA-.. Multifunctional linear actuators for adjusting air dampers and slide valves in ventilation and air-conditioning systems for building services installations For air control dampers

More information

Excellent low-cost Process & Temperature Controllers

Excellent low-cost Process & Temperature Controllers C22 C62 C82 C83 Excellent low-cost Process & Temperature Controllers C72 C42 R22 01. High Quality LCD Display 02. High Accuracy 18 Bit A-D Input and 15 Bit D-A Output 03. The Fast Sampling Rate in 200

More information

Functional data Factory settings Variable Settings

Functional data Factory settings Variable Settings echnical data sheet Rotary actuator RF-MF(-O) Multifunctional rotary actuator with emergency control for and 3 way control ball valve orque Nm Nominal voltage AC/DC V Control: Modulating DC... V or variable

More information

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC Characteristics time delay relay 10 functions - 1 s..100 h - 12..240 V AC/DC - 1 OC Main Range of product Product or component type Discrete output type Width Device short name Time delay type Time delay

More information

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC Characteristics time delay relay 10 functions - 1 s..100 h - 12..240 V AC/DC - 1 OC Main Range of product Product or component type Discrete output type Width Device short name Time delay type Time delay

More information

Corrigo E. Lon-interface variable list Covers all versions of Corrigo E.-LON from revision Revision: 8 Date:

Corrigo E. Lon-interface variable list Covers all versions of Corrigo E.-LON from revision Revision: 8 Date: Corrigo E Lon-interface variable list Covers all versions of Corrigo E.-LON from revision 1.2-1-0 Revision: 8 Date: 11-08-19 Copyright AB REGIN, Sweden, 2011 About the manual This document covers all versions

More information

STR-LCF. Security Advice Caution. Notes on Disposal. Electronic Fan Coil Thermostat (Flush mounting) Datasheet. Application

STR-LCF. Security Advice Caution. Notes on Disposal. Electronic Fan Coil Thermostat (Flush mounting) Datasheet. Application STR-LCF Electronic Fan Coil Thermostat (Flush mounting) Datasheet Subject to technical alteration Issue date: 28.2.217 Application The fan coil room thermostat has been designed for individual control

More information

Excel 10 W7751B,D,F VAV Controllers

Excel 10 W7751B,D,F VAV Controllers Excel 0 W77B,D,F VAV Controllers INSTALLATION INSTRUCTIONS BEFORE INSTALLATION The Excel 0 VAV Controller is a Free Topology Transceiver (FTT) LonMark compliant device that is available in three versions:

More information

Application Sheet Fan coil unit with staged fan, heating/cooling coil (2 pipe) on triac output and electric reheater

Application Sheet Fan coil unit with staged fan, heating/cooling coil (2 pipe) on triac output and electric reheater Heating with LHW and cooling with CHW changeover Modulating control of heating and cooling valve (2 pipe) on triac Automatic or manual 3-speed fan control Room temperature and fan speed operation via KNX

More information

Outside Temperature Sensors

Outside Temperature Sensors 1 814 1814P01 Symaro Outside Temperature Sensors QAC31 Active sensors for acquiring the outside temperature Operating voltage AC 24 V or DC 13535 V Signal output DC 010 V or 420 ma Use The QAC31 outside

More information

Compact room automation stations, BACnet/IP, AC 24 V

Compact room automation stations, BACnet/IP, AC 24 V Desigo Room Automation Compact room automation stations, BACnet/IP, AC 24 V DXR2.E12P.., DXR2.E12PX.., DXR2.E18.. For building with increased demands placed on functionality and flexibility in Room Automation

More information

21 VA (l max 20 5 ms) Connection Cable 1 m, 4 x 0.75 mm 2 Functional data Factory settings Variable Setting Torque Inhibiting torque

21 VA (l max 20 5 ms) Connection Cable 1 m, 4 x 0.75 mm 2 Functional data Factory settings Variable Setting Torque Inhibiting torque echnical data sheet GK4A- Communicative SuperCap rotary actuator with emergency setting function and extended functionalities for adjusting air dampers in ventilation and air-conditioning systems for building

More information

Application Sheet Fan coil unit with variable fan, heating/cooling coil (2 pipe) on triac output and electric reheater

Application Sheet Fan coil unit with variable fan, heating/cooling coil (2 pipe) on triac output and electric reheater Heating with LHW and cooling with CHW changeover Modulating control of heating and cooling valve (2 pipe) on triac Automatic or manual variable fan speed control DC 0...10 V Room temperature and fan speed

More information

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC Characteristics on-delay timing relay - 1 s..100 h - 24..240 V AC - 1 OC Complementary Contacts material Control type [Us] rated supply voltage Voltage range Main Range of product Product or component

More information

Technical data V phase cut, input impedance 8.2 k Position feedback (measuring voltage U) DC V, max. 0.5 ma Start point DC

Technical data V phase cut, input impedance 8.2 k Position feedback (measuring voltage U) DC V, max. 0.5 ma Start point DC echnical data sheet SMA-PC Parameterisable damper actuator for adjusting air dampers in ventilation and air-conditioning systems in buildings Air damper size up to approx. m orque 0 Nm Nominal voltage

More information

ELECTRONIC THERMOSTAT: T920

ELECTRONIC THERMOSTAT: T920 μnistδt ELECTRONIC THERMOSTAT: T One analog output DESCRIPTION The T series thermostats are microcomputer-based, proportional and integral (PI) devices with one analog 0 to 0 output. They can be used with

More information

CAN-IO Custom IO remote module

CAN-IO Custom IO remote module CAN-IO Custom IO remote module Main characteristics High customization Integrate different types of inputs/ outputs Up to 40 total channels DIN rail mount or plate Main applications Climatic chambers Autoclaves

More information

UniStream 5" Technical Specifications US5-B5-RA28, US5-B10-RA28

UniStream 5 Technical Specifications US5-B5-RA28, US5-B10-RA28 UniStream 5" Technical Specifications US5-B5-RA28, US5-B10-RA28 Unitronics UniStream 5" are PLC+HMI All-in-One programmable controllers that comprise built-in HMI and built-in I/Os. The series is available

More information

EMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description.

EMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description. Electronic monitoring relay for voltage monitoring in three-phase networks INTERFACE Data sheet 102110_en_03 1 Description PHOENIX CONTACT - 09/2009 Features Increasingly higher demands are being placed

More information