WIRING DIAGRAM EXAMPLE EXEMPLE DE SCHEMA DE CABLAGE
|
|
- Jeffry Reynolds
- 5 years ago
- Views:
Transcription
1 Revision Modification Date Auteur Controle APPR. WIRING DIAGRAM EXAMPLE EXEMPLE DE SCHEMA DE CABLAGE Website: Technical support: + (0) support@cretechnology.com SKYPE: support-cretechnology.com 0, Allée Victor Naudin Zone des Templiers Sophia-Antipolis 0 Biot - FRANCE Phone: + (0) Fax: + (0) AZ000_a_Wiring diagram example Generator on mains Dessiné le : Modifié le : Mars 0 0/0 0
2 Folio A B C D E F G H I J K L M N O P Q Désignation Indice A B C D Date Présentation Summary Single line diagram / Schéma unifilaire Power wiring / Câblage de puissance Digital input wiring / câblage entrées logiques Digital input wiring / câblage entrées logiques Governor & Engine control/câblage régulation et Moteur Digital output and AVR /sorties logique et AVR Analogue Inputs / Entrées analogiques Power transducer / Mesure réseau -0mA (option) Not use: COM Inter Gensys.0 Communication COM J / I/O extension COM Modbus RTU // // // // // // Folio Désignation Indice Date A B C D Summary Dessiné le : Mars 0 0 Modifié le : 0/0
3 Speed controler Mains power measurement by transducer AVR Current Voltage Current (Mains power measurement by CT) Voltage I U Cde Breaker LOAD Utilisation Cde Breaker U I Mains Transducer (optionnal if no CT) kw to -0mA signal GE RESEAU/ MAINS Gen breaker Main breaker Single line diagram / Schéma unifilaire Dessiné le : Mars 0 0 Modifié le : 0/0
4 LOAD Utilisation Gen breaker Mains breaker N J J L P P P P ~ G L S S P P S S P P L S S P S S P S S P P S S FUG M MX MN MX MN M FUS Common Close Open Close Open Common B B B B D D D D D D E E E E E E L L L L L L B B B GENSYS.0 Generator voltage Generator Current Mains Current Mains voltage 0/00V A to A A to A 0/00V GENERATOR MAINS CONTROLE GROUPE CONTROLE RESEAU Power wiring / Câblage de puissance Dessiné le : Mars 0 0 Modifié le : 0/0
5 Mains breaker Position Gen breaker Position P Mains breaker IN Gen breaker IN Remote start:stop Spare J oil pressure Spare J Water temp. J J J J J J J J Exemple de câblage Exemple de câblage wiring example wiring example 0 T GENSYS.0 Digital input wiring / câblage entrées logiques Dessiné le : Mars 0 0 Modifié le : 0/0
6 J J J J J J J GENSYS.0 Digital input wiring / câblage entrées logiques Dessiné le : Mars 0 0 Modifié le : 0/0
7 Optionnal diode FUCA FUCB External tank capacitor (optional) for DC only 000uF min AU K K K A GENSYS.0 Power supply - Pickup + G Power tank Pickup - G Power supply + Crank relay A Emergency Stop + Fuel relay A Speed out + G Shield G Speed ref G Pwm outpout K Speed OUT + Speed reférence D +Bat Speed bias Réf - B Reg vitesse analogique speed controller Governor & Engine control/câblage régulation et Moteur Dessiné le : Mars 0 0 Modifié le : 0/0
8 GENSYS.0 C Output C Output C Output C Output C Output H AVR out + H Shield H AVR out - H AVR out + H AVR out - KA KA KA KA Exemple de câblage wiring example IN + IN - Regulateur tension AVR Output Output Output Output BUZZER 0 F 0 F 0 F 0 F 0 F Digital output and AVR /sorties logique et AVR Dessiné le : Mars 0 0 Modifié le : 0/0
9 GENSYS.0 F Fuel level/spare - 0/ Kohms F Fuel level/spare + F Oil level/spare - 0/ Kohms F Oil level/spare + F Shield F Water temp. - 0/00 ohms F Water temp. + F OIL Pressure - 0/00 ohms F OIL Pressure + IF chassis connected to IF chassis not connected to Analogue Inputs / Entrées analogiques Dessiné le : Mars 0 0 Modifié le : 0/0
10 BUS LINE / Phase Bus POWER TRANSDUCER kw to -0mA Convertisseur P réseau kw / -0mA P kw to /0mA To use if no mains Current Transfromer connected Utilisation si pas de tranformateur de courant réseau G G G G G G Input +-0mA Shield Input +-0mA Parallel - Shield Parallel + GENSYS.0 Power transducer / Mesure réseau -0mA (option) Dessiné le : Mars 0 Modifié le : 0/0
11 Resistor Switch ON 0 Ohms ON COM NC CAN-L GROUND- NC GROUND- GROUND- CAN-H NC NC C0M GENSYS Non utilisé en utilisation GENSYS.0 couplage réseau Not connected if single GENSYS.0 on mains paralleling operation Can L Can H Ground Not used: COM Inter GENSYS.0 Communication Dessiné le : Mars 0 Modifié le : 0/0
12 Resistor Switch ON 0 Ohms ON COM Can L Can H NC CAN-L GROUND- NC GROUND- GROUND- CAN-H NC NC C0M CAN OPEN GND CAN OPEN The 0 Ohms termination resistor must be present on both sides can H can L can GND can H can L can GND La résistance de 0 Ohms de terminaison doit être mise en service au deux extrémités CAN OPEN + J R 0 Ohms ECM / ECU R 0 Ohms if no ECU Not Available on Gensys.0LT Non disponible sur Gensys.0LT COM J / I/O extension Dessiné le : Mars 0 Modifié le : 0/0
13 NC COM RJ NC GROUND GROUND B A NC NC GROUND ETHERNET TCP/ IP Resistor Switch ON 0 Ohms ON C0M GENSYS.0_RS COM Modbus RTU A Ground B A Ground B GTC/GTB Modbus RTU Connexion des autres modules sur la ligne Modbus RTU Other devices connection on Modbus RTU line The 0 Ohms termination resistor must be present on both sides La résistance de 0 Ohms de terminaison doit être mise en service au deux extrémités COM Modbus RTU Dessiné le : Mars 0 Modifié le : 0/0
DEIF A/S. Application Notes. Basic Gen-set Controller. Single generator set. Automatic mains failure. Parallel with mains (grid)
Basic Gen-set Controller 4189340316B Single generator set Automatic mains failure Parallel with mains (grid) DEIF A/S Load sharing multiple sets DEIF A/S, Frisenborgvej 33 Tel.: +45 9614 9614, Fax: +45
More informationINSTALLATION INSTRUCTION #44E
Saint-Lazare, Québec Tel.: (450) 455-0961 Calmar, Alberta Tel.: (780) 985-3636 Rockledge, Florida Tel.: (321) 638-2364 INSTALLATION INSTRUCTION #44E ELECTRONIC THERMOSTAT Model No. UTC-2030-(program code
More informationFD470 RAILWAY RELAY, 2 PDT-DB-DM, 3 AMP / 72VDC RELAIS FERROVIAIRE, 2 R (DC)+ 2 T (DE)/ 3 A / 72VCC
Polarized, non-latching hermetically sealed relay Relais hermétique monostable polarisé Contact arrangement Combinaison des contacts Coil supply Alimentation bobine Qualified or in accordance with Qualifié
More informationDIFFERENTIAL CURRENT GENERATOR «POCDIF» (AC/DC - 32A - 50V - 12 ranges)
PERFORMANCES 12 ranges of AC current from 16 ma to 128 A peak AC permanent current up to 26 ARMS Nine ranges of DC permanent current from 16 ma to 12 A DC current ± 6mA or ± 10 ma stackable to AC current
More informationDEIF A/S. Description of options. Option H3 Serial communication Profibus DP Multi-line 2 version 2. Description of option. Functional description
Description of options Option H3 Serial communication Profibus DP Multi-line 2 version 2 4189340279I SW 2.42.X Description of option Functional description DEIF A/S Parameter table Data tables DEIF A/S,
More informationARC-MC. Data warehousing board for drivers, measuring and monitoring board for power systems
ARC-MC Data warehousing board for drivers, measuring and monitoring board for power systems DIN41651 connector technology Input: 1 x 26-pin connector Output: 3 x 14-pin connectors or 1 x 26-pin connector
More informationTable of Contents. HWIO-Gateway User Manual
User Manual HWIO-Gateway INUX AB Katrinedalsg. 3, 504 51 Borås http://www.inux.se Copyright 2009 Uppdaterad 2010-01-12 Copyright 2009 INUX AB 1 Table of Contents 1. Product overview...3 2. License...3
More informationATV12H018F1 variable speed drive ATV kW hp V - 1ph
Characteristics variable speed drive ATV12-0.18kW - 0.25hp - 100..120V - 1ph Main Range of product Altivar 12 Product or component type Product destination Product specific application Assembly style Component
More informationOption H2, Modbus communication Automatic Gen-set Controller H SW version 2.33.X
Description of options Option H2, Modbus communication Automatic Gen-set Controller 4189340356H SW version 2.33.X Description of option Parameter list DEIF A/S Data tables Parameter table DEIF A/S, Frisenborgvej
More information1M122A Transformer Parallel Control System
Technical Bulletin 1M122A Transformer Parallel Control System Features CONTROL SYSTEM FEATURES Simple system wiring Scaleable up to 4 transformers Flexible control configuration Set transformers in any
More informationIP1 Datasheet PWM OUTPUT WITH SINGLE CHANNEL ADC MODULE FEATURES DESCRIPTION CONNECTOR DETAILS
PWM OUTPUT WITH SINGLE CHANNEL ADC MODULE FEATURES 1 PWM Output (3.3V) 0 Hz 1 khz Single Channel 3.3V 12-bit ADC input for voltage sensing Optional automated PWM adjustment based on input voltage for standalone
More informationATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink
Characteristics variable speed drive ATV12-0.37kW - 0.55hp - 100..120V - 1ph - with heat sink Main Range of product Altivar 12 Product or component type Product destination Product specific application
More informationPECA 30E. Analyseur de signaux alternatifs Signal Analyser for Electrical Networks
Analyseur de signaux alternatifs Signal Analyser for Electrical Networks Tout type de réseau : monophasé, triphasé équilibré avec ou sans neutre All types of network: single phase, 3-phase balanced, unbalanced,
More informationMeasuring transducers
Measuring transducers MT4xx and (U)MT5xx Measuring transducer MT440 MT 440 Programmable multifunctional transducer Real time measurements of more than 50 quantities Power accuracy class 0.5 16 adjustable
More informationDOCUMENTATION. The new XALIS 9000 integrates a 32 bits microprocessor offering some more of performance.
DOCUMENTATION The new integrates a 32 bits microprocessor offering some more of performance. XALIS is a new digital indicator range with 2 colors numerical and alphanumerical display designed to provide
More informationAKP-AKU DIGITAL PANEL METER
DIGITAL PANEL METER AKP-AKU Isolated digital indicators AKP and AKU are designed to provide display and signals transmission solutions. Its unique programmation principle on front plate or by digital output
More informationATV12HU40M3 variable speed drive ATV12-4kW - 5hp V - 3ph - with heat sink
Characteristics variable speed drive ATV12-4kW - 5hp - 200..240V - 3ph - with heat sink Main Range of product Altivar 12 Product or component type Product destination Product specific application Assembly
More informationMICROFUSION FEATURES OPTIONS CERTIFICATIONS THREE PHASE SCR POWER CONTROLLERS
MICROFUSION THREE PHASE SCR POWER CONTROLLERS FEATURES Auto-Ranging Input Voltage 24-600 VAC, 45-65 Hz AC Output 8, 16, 32, 50, 80 Amps (@ 50 C 6000 ft) Control Features Microprocessor-based controller
More informationInstallation NOTICE. SpeedNet Cell Edge Gateway software can be downloaded at sandc.com/en/
S&C SpeedNet Cell Edge Gateway Table of Contents Section Page Introduction Section Page Shipping and Handling Qualified Persons............................. Read this Instruction Sheet......................
More informationDEIF A/S. Application note. Generators parallel with mains Multi-line 2 version 2. Application description. Power import control. Power export control
Generators parallel with mains Multi-line 2 version 2 4189340363B Application description Power import control DEIF A/S Power export control DEIF A/S, Frisenborgvej 33 Tel.: +45 9614 9614, Fax: +45 9614
More informationOcean Controls KT-5221 Modbus IO Module
Ocean Controls Modbus IO Module 8 Relay Outputs 4 Opto-Isolated Inputs 2 Analog Inputs (10 bit) 1 PWM Output (10 bit) 4 Input Counters Connections via Pluggable Screw Terminals 0-5V or 0-20mA Analog Inputs,
More information+ 24V 3.3K - 1.5M. figure 01
ELECTRICITY ASSESSMENT 35 questions Revised: 08 Jul 2013 1. Which of the wire sizes listed below results in the least voltage drop in a circuit carrying 10 amps: a. 16 AWG b. 14 AWG c. 18 AWG d. 250 kcmil
More informationB850 Boiler House Energy Monitor
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationR24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY
Čapkova 22 678 01 Blansko tel.: +420 516 416942, 419995 fax: +420 516 416963 R24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY Display module is designed for measuring the resistance, the signal from the
More informationNew Laboratory Stand and Teaching Program Transformer Monitoring System
New Laboratory Stand and Teaching Program Transformer Monitoring System Ryszard Kowalik, Paweł Kopański, Krzysztof Glik Warsaw University of Technology/Institute of Power Engineering Warsaw, Poland ryszard.kowalik@ien.pw.edu.pl,
More informationWeighing Instruments. Applications. Characteristics. DMS strain gauges (load cells), DMS amplifier
GHM GROUP CORPORATE GHM Messtechnik GmbH Schloßstr. 6 88453 Erolzheim GERMANY Phone +49 7354 937233-76 Fax +49 7354 937233-88 Weighing System Evaluation Mounting DMS strain gauges (load cells), DMS amplifier
More informationBAS Integration Manual
Snow Melting Control 680 Introduction BAS Integration Manual Snow Melting 680_B 10/15 Replaces: 04/15 The Snow Melting Control 680 can communicate with a Building Automation System (BAS) using either BACnet
More informationSyvecs Limited. Syvecs
Syvecs Limited Syvecs S8 Pinouts and Wiring Info Support Team 03 02 2014 This document intended for use by a technical audience and describes a number of procedures that are potentially hazardous. Installations
More informationINSTRUCTIONS MANUAL DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS HRI-R40W
Page 2 / 16 INDEX: GENERAL TYPES ACESSORIES AND OPTIONS INSTALLATION WIRING DIAGRAMS CONNECTING TERMINALS DIAGRAMS WIRING DIAGRAM DESCRIPTION WORKING DESCRIPTION AND KEYBOARD WORKING DESCRIPTION AND PROGRAMMING
More informationcelduc r e l a i s Proud to serve you XKLD31006 DOCUMENT PRELIMINAIRE RELAIS STATIQUE A MOSFET POUR COURANT CONTINU 10-30VDC 40V (60V crête) 10ADC
DOCUMENT PRELIMINAIRE RELAIS STATIQUE A MOSFET POUR COURANT CONTINU Montage rail DIN Technologie à base de MOSFET dernière génération. Très faible résistance à l état passant. Protection contre les surtensions
More informationATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink
Characteristics variable speed drive ATV12-0.37kW - 0.55hp - 100..120V - 1ph - with heat sink Product availability : Stock - Normally stocked in distribution facility Price* : 191.76 USD Main Range of
More informationWeighing Instruments
GHM Messtechnik GmbH Sales Center International Schloßstraße 6 88453 Erolzheim Germany Fon +49-7354-937233-0 Fax -88 www.ghm-messtechnik.de info@ghm-messtechnik.de Weighing Instruments System Evaluation
More information1U Rack Mountable Control and Monitor Unit
Bauart gepruft Sicherheit egelma ge od o s be wac g www. tuv.com ID 000000000 Providing exceptional customer service since 9 U Rack Mountable Control and Monitor Unit MEAN WELL RKP-CMU Series File Name:RKP-CMU-SPEC
More informationINDUSTRIAL OPTO-ISOLATED RS-232 REPEATER
QUICK START GUIDE ICD201A INDUSTRIAL OPTO-ISOLATED RS-232 REPEATER 24/7 TECHNICAL SUPPORT AT 877.877.2269 OR VISIT BLACKBOX.COM STEP 1 - What s Included ICD201A Industrial Opto-Isolated RS-232 to RS-422/485
More informationG.C.R. Digital mains commander Ref. A09T0 / 100 VAC Ref. A09T1 / 230 VAC Ref. A09T2 / 400 VAC
G.C.R. November 2000 Digital mains commander Ref. A09T0 / 100 VAC Ref. A09T1 / 230 VAC Ref. A09T2 / 400 VAC Technical documentation and calibration Ref : A09T090004-D DSF Technologies SA believes that
More informationSpecification For Approval
Specification For Approval Customer : Description : Customer Part No. : Delta Model No. : Safety Model No. : Sample Issue No. : Sample Issue Date : EC FAN GTB040PUD26R N1 GTB040PUD26 05/24/2017 Rev : Please
More informationD SERIES EM16 IP 20 / NEMA 1 & IP 66 / NEMA 4X COMPACT VECTOR CONTROL DRIVE EM 16 COMPACT VECTOR CONTROL DRIVE
D SERIES EM16 IP 20 / NEMA 1 & IP 66 / NEMA 4X COMPACT VECTOR CONTROL DRIVE EM 16 COMPACT VECTOR CONTROL DRIVE 1 2 SERIES 1 2 pag. 4 pag. 5 Applications Model identification 3 pag. 5 4 pag. 6 Capacity
More informationCompact IP20 Multiprotocol Ethernet I/O Station 4 Digital PNP Inputs and 4 Configurable Digital PNP Channels FEN20-4DIP-4DXP-DIN
EtherNet/IP Slave Modbus TCP Slave PROFINET Slave Integrated Ethernet Switch 10 Mbps / 100 Mbps 2 x RJ45 Sockets for Fieldbus Connection Can be mounted on DIN rail 4 digital PNP inputs 4 configurable PNP
More informationVitocontrol-C, Ecotronic KRT PN:
70 McMurray Road, Waterloo, Ontario NV G Vitocontrol-C, Ecotronic KRT 0-00 PN: 70 Project Project No. : : PRJ-000 Technical data Power supply Main fuse Dimensions Degree of protection : : : : 0V, 60Hz,
More information1 INTRODUCTION 1.1 PRODUCT DESCRIPTION
GEK-00682D INTRODUCTION INTRODUCTION. PRODUCT DESCRIPTION The MDP Digital Time Overcurrent Relay is a digital, microprocessor based, nondirectional overcurrent relay that protects against phase-to-phase
More informationMULTI-LINE 2 DESCRIPTION OF OPTIONS. Option N Ethernet/IP. Document no.: B
MULTI-LINE 2 DESCRIPTION OF OPTIONS Option N Ethernet/IP Document no.: 4189340801B This description of options covers the following products: -3-4 PPM-3 GPC-3/GPU-3/GPU-3 Hydro/PPU-3 SW version 3.31. or
More informationsw rev. 55B DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS
INSTRUCTIONS MANUAL IM831-U v0.92 HRI-R40W sw rev. 55B DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS INDEX: GENERAL TYPES ACESSORIES AND OPTIONS
More informationProtection Relays. U-MLEs-PLv. Ultra Line. DC SUBSTATION PROTECTIVE RELAY (double voltage Line Test) 32, 45, 49, 64, 76, 79, 80
Ultra Line DC SUBSTATION PROTECTIVE RELAY (double voltage Line Test) 3, 45, 49, 64, 76, 79, 80 D.C. Feeder protection relay with setting parameters programmable locally or via serial communication. Suitable
More informationContents. Introduction and description Package contents Device identification PM Options... 80
Contents 1 Introduction and description Package contents... 77 Device identification... 77 2 Characteristics PM500... 78 Options... 80 3 Installation Front-panel cut-out... 82 Mounting... 82 4 Connections
More informationCombination Generator Control Module
User Manual Combination Generator Control Module Catalog Number 1407-CGCM-DLR Important User Information Read this document and the documents listed in the additional resources section about installation,
More informationATV12HU22M2. Main. Range of product Altivar 12. Component name Quantity per set Set of 1. Built-in fan. Motor power hp Communication port protocol
Product datasheet Characteristics ATV12HU22M2 Complementary Main Range of product Altivar 12 Product or component type Product destination Product specific application Assembly style Component name Variable
More informationD SERIES LM16. COMPACT DRIVE V/f and SLV CONTROL. LM16 COMPACT DRIVE V/f and SLV CONTROL
D SERIES LM16 COMPACT DRIVE V/f and SLV CONTROL LM16 COMPACT DRIVE V/f and SLV CONTROL 1 2 SERIES 1 2 page 4 page 6 Introduction Fields of application 3 page 7 4 page 8 Designation Product offer 5 6 page
More informationENGINEERING DATA SUBMITTAL For the Interconnection of Generation System
WHO SHOULD FILE THIS SUBMITTAL: Anyone in the final stages of interconnecting a Generation System with Nodak Electric Cooperative, Inc. This submittal shall be completed and provided to Nodak Electric
More informationFLOW RATE CORRECTION CALCULATOR GDR 1403
FLOW RATE CORRECTION CALCULATOR GDR 1403 with Ethernet TCP/IP, Profibus-DP, MODBUS-RTU, MODBUS-TCP The correction calculator GDR 1403 measures volume or mass flow of flow rate sensors. Within volume flow
More informationB850 Boiler House Energy Monitor
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationElectronic Preset Delivery System. AccuLoad II TM. Installation. The Most Trusted Name In Measurement
Electronic Preset Delivery System AccuLoad II TM Issue/Rev. 0.8 (8/95) Installation Bulletin MN06037 The Most Trusted Name In Measurement Section 1 - General J4 J5 J3, J6, J7 and J8 J1 J2 Figure
More informationAmerican Power Design, Inc.
FEATURES 4 Customer Selects Output Voltage 4 Outputs to 28 Vdc 4 Wide Input Ranges (10-20Vdc, 18-36Vdc, 20-60Vdc, 36-72Vdc) 4 Excellent Line & Load Regulation 4 Low Output Ripple 4 500 Vdc Output Isolation
More informationVFSC9 ELECTRONIC SPEED CONTROLLER. Mounting and operating instructions
ELECTRONIC SPEED CONTROLLER Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 5 WIRING
More informationWireless Sensor for Humidity / Temperature / CO 2
State of the art sensor technology, highest reliability of data transmission and the ease of system installation are the outstanding features of the wireless sensor series EE240. Wireless Sensor for Humidity
More informationIRAMX16UP60A Series 16A, 600V
Integrated Power Hybrid IC for Appliance Motor Drive Applications. Features PD-94684 RevF IRAMX16UP60A Series 16A, 600V Description International Rectifier's IRAMX16UP60A is an Integrated Power Module
More informationEFC 3600 Frequency converter for higher energy efficiency and improved process control
EFC 3600 Frequency converter for higher energy eiciency and improved process control 2 Valuable energy used responsibly Rising energy costs and increasing demands on the environmentally sound products
More informationDOCUMENTATION. Its affordable price allows you to meet your budget target.
DOCUMENTATION ULCOS is a real concentrate of technology, mixing performance and versatility. It is able to meet your high level expectation, for technical tender specifications. Its affordable price allows
More informationFICHE TECHNIQUE RELAIS
Groupe 02-04-01-00 Type machine : No. série machine : CODE : FICHE TECHNIQUE RELAIS Exemple................................................................................................................................................................................................................................
More informationPumping of clear unfilled liquids in housing, agricultural and industrial sectors.
operating limits Flow rates up to : 98 m 3 /h Head up to : Max. discharge pressure : Max. suction pressure : Temperature range : 25 m CE 16 et 25 bar 1 bar - 15 to +12 C* Max. ambient temperature : + 4
More informationSystem configuration. Ratings 400 V Class three-phase 90 to 800 kw 690 V Class three-phase 90 to 1000 kw SX-D. Frequency inverters.
~ ~ SX High performance Vector Control IP54 full range. Compact design & Robustness Built-in Filter according to C3 Class Built-in Fusses (From 200 kw) Safety according EN13849-1 and EN62061 standards
More informationMICROPROCESSOR-BASED METERING EQUIPMENT SECTION 16901C PART 2
PART 1 PART 2 PRODUCTS 2.01 MANUFACTURERS A. Eaton products B.. C.. The listing of specific manufacturers above does not imply acceptance of their products that do not meet the specified ratings, features
More informationSRC-110 Series Zone Controllers with Modbus RTU
Product sheet CT2.142 Type SRC-110-MOD SRC-110 Series Zone Controllers with Modbus RTU The SRC-110 series controllers have been designed for zone heating and cooling control. The controllers have 3 analogue
More informationSX (400V) System configuration
~ ~ SX (400V) High performance Vector Control IP54 full range. Compact design & Robustness Built-in Filter according to C3 Class Built-in Fusses (From 200 kw) Safety according EN13849-1 and EN62061 standards
More informationNew Eagle PWM to Analog Converter
New Eagle P.O. Box #272 Ann Arbor, MI 48105-2603 Phone 734.395.2112 Fax 928.395.2114 M E C H A T R O N I C C O N T R O L S O L U T I O N S New Eagle PWM to Analog Converter Revision 0.2 PWM-AN-024-1403
More informationPRODUCT LEAFLET AUGIER-BOX. Remote Monitoring Unit for Street Lighting /07/2011
PRODUCT LEAFLET AUGIER-BOX Remote Monitoring Unit for Street Lighting 1 60 11432-04/07/2011 Put a TECHNICIAN in each street lighting cabinet, and control them 24H per day! The Augier-Box Programmable Logic
More informationSX (690 V) System configuration
SX (690 V) High performance Vector Control IP54 full range Compact design & Robustness Built-in Filter according to C3 Class Built-in Fuses (From 200 kw) Safety according EN13849-1 and EN62061 standards
More informationSX (400 V) System configuration
~ ~ SX (400 V) High performance Vector Control IP54 full range. Compact design & Robustness Built-in Filter according to C3 Class Built-in Fuses (From 200 kw) Safety according EN13849-1 and EN62061 standards
More informationVersion number A=standard P=Cold Plate (Frame A only) T=Brake chopper (Frame A only) Input voltage 11=115VAC 21=230VAC 1φ 23=230VAC 3φ 43=400VAC
Type number key VFD 007 E 43 A Version number A=standard P=Cold Plate (Frame A only) T= (Frame A only) Input voltage 11=115VAC 21=230VAC 1φ 23=230VAC 3φ 43=400VAC VFD-E series Power 007=0.75kW 022=2.2kW
More informationModbus communication module for TCX2: AEX-MOD
Modbus communication module for TCX2: Communication Specification TCX2 is factory installed in TCX2 series controllers with -MOD suffix, and is also available separately upon request for customer installation
More information4012 en / b. Digital Voltage Regulator D610. Instruction manual
4012 en 10.2009 / b Digital Voltage Regulator D610 Instruction manual NOTE THE ELECTRICAL WIRING DIAGRAM ARE ONLY GIVEN AS AN INDICATION. PLEASE REFER TO THE SPECIFIC DIAGRAMS OF YOUR ALTERNATOR WARNING
More informationMULTIFUNCTION GRAPHICAL UNIT MGU 800
MULTIFUNCTION GRAPHICAL UNIT MGU 800 For display, recording and evaluation of process instruments signals (level, temperature, pressure, etc.) 3.5" TFT display, multi-language menu Variety of possible
More informationTVB-2 INSTRUCTION SHEET. Test Verification Box
TVB- INSTRUCTION SHEET Test Verification Box V.07.08 DECLARATION OF CONFORMITY Manufacturer: Address: Product Name: Model Number: Associated Research, Inc. 3860 W. Laurel Dr. Lake Forest, IL 60045, USA
More informationSpecification For Approval
Specification For Approval Customer : Description : Customer Part No. : Delta Model No. : Safety Model No. Sample Issue No. : Sample Issue Date : EC FAN GTW063EUD19R 01/24/2017 Rev : Please send one copy
More informationFM Radio Transmitter & Receiver Modules
Features Miniature SIL package Fully shielded Data rates up to 128kbits/sec Range up to 300 metres Single supply voltage Industry pin compatible T5-434 Temp range -20 C to +55 C No adjustable components
More informationAmerican Power Design, Inc.
FEATURES 4 Customer Selects Output Voltage 4 Outputs to 1000 Vdc 4 Fully Programable Outputs 4 Single and Dual Outputs 4 Wide Input Ranges (10-20Vdc, 18-36Vdc) 4 1000 Vdc Output Isolation 4 Continuous
More informationIRAMX16UP60B Series 16A, 600V
PD-96-957 RevC IRAMX16UP60B Series 16A, 600V Integrated Power Hybrid IC for Appliance Motor Drive Applications. Description with Internal Shunt Resistor International Rectifier's IRAMX16UP60B is a 16A,
More informationPower connections, minimum and maximum wiring capabilities, tightening torque
Wiring - power terminals Power Observe the cable cross-sectional areas recommended in the standards. The soft starter must be grounded to conform to the regulations concerning leakage currents. If the
More informationVKI3. Inductive strip edge position control for rolling mills. single-side robust maintenance-free
VKI3 Inductive strip edge position control for rolling mills single-side robust maintenance-free VKI3 Strip edge position control of metal str Operating principle: In advanced rolling mills, knowledge
More informationP/N: AX TECHNICAL DATASHEET #TDAX Single Input, Dual Output Valve Controller 1 Universal Input, +5V reference CAN (SAE J1939)
TECHNICAL DATASHEET #TDAX022000 Single Input, Dual Output Valve Controller 1 Universal Input, +5V reference (SAE J1939) Features: 1 universal signal input 2 proportional or on/off outputs up to 3 A User
More informationSW r e l a i s. INVERSEURS DE SENS DE ROTATION MOTOR REVERSER ( Ready to use) 3x400VAC 4KW Boitier IP20 IP20 housing.
INVERSEURS DE SENS DE ROTATION MOTOR REVERSER ( Ready to use) Le relais 6123 est étudié pour démarrer et inverser le sens de rotation de moteurs triphasés asynchrones, avec la commutation de 2 phases uniquement
More informationmicro Technical Manual
GB micro opos 4 Positioning system Progr. version M001B110 Technical Manual Servo unit micropos 4 Contents 1. Introduction... 1 1.1. General... 1 1.2. System survey... 2 1.3. Master... 3 Modbus RTU or
More informationDEIF A/S. Description of options. Option H1 Serial communication CAN open. Description of options. Functional description. Tables.
Description of options Option H1 Serial communication CAN open 4189340277G SW version 2.42.X Description of options Functional description DEIF A/S Tables Parameter list Object dictionary DEIF A/S, Frisenborgvej
More informationCO2 Engine - ICB Sensor module for bio applications
Product Manual CO2 Engine - ICB Sensor module for bio applications SE 0025 10% CO2 Sensor Module SE 0026 30% CO2 Sensor Module CM 0058 10% CO2 Development Kit CM 0027 30% CO2 Development Kit General CO
More informationElectrical data Nominal voltage AC/DC 24 V Nominal voltage frequency
echnical data sheet GM24A--P Communicative damper actuator for adjusting dampers in technical building installations Air damper size up to approx. 8 m² Nominal torque 4 Nm Nominal voltage AC/DC 24 V Control
More informationPicture. Digital output signal (pressure and temperature) RS-485 Modbus RTU, 9600 bps Protocol details see Data Sheet SW
Type: for level measurement Order No.: see Table 1 / Page 4 Features Picture Four wire system Piezoresistive measuring element Pressure measurement relative or absolute Output signal 4-20 ma and RS-485
More informationGraphical symbols for diagrams
BRITISH STANDARD BS EN 60617-6:1996 IEC 617-6: 1996 Graphical symbols for diagrams Part 6: Production and conversion of electrical energy The European Standard has the status of a British Standard ICS
More informationAPM 6998 WiFi Module Manual
Host Revision Information APM 6998 WiFi Module Manual Host Hardware Revision Host Module Driver Version Module Hardware Revision T3x Rev D1 v8.1.4.4 001E Host PCB Design Guidelines The following guidelines
More informationMLX83100 Automotive DC Pre-Driver EVB83100 for Brushed DC Applications with MLX83100
EVB83100 for Brushed DC Applications with MLX83100 Stefan Poels JULY 17, 2017 VAT BE 0435.604.729 Transportstraat 1 3980 Tessenderlo Phone: +32 13 67 07 95 Mobile: +32 491 15 74 18 Fax: +32 13 67 07 70
More informationCommunication. Versatronik 532 & 532D Solar Communication Gateway for solar controls Modbus. Technical, Installation and Configuration Information
Versatronik 532 & 532D Solar Communication Gateway for solar controls Modbus Document Applicable to: Versatronik 532 Solar/Modbus P/N 704089 Versatronik 532D Solar/Modbus P/N 704090 Communication Applicable
More informationCONTROL MANUAL. Dry-Pic 09PE - 09VE
CONTROL MANUAL Dry-Pic 09PE - 09VE Translation of the original document 003, 04.01 EN CONTENTS PAGE 1 - IMPORTANT RECOMMENDATIONS 1.1 Power supply 1. Electronic board specifications 1.3 Caution 1.4 Earth
More informationS11 Adjustable Speed Drive Engineering Specification
PART 1 - GENERAL 1.0 Scope This specification shall cover Toshiba S11 AC Variable Frequency Drives, 6 pulse for 3- phase 200-240VAC, 380-500VAC and single phase 200V to 240VAC. 1.1 References A. National
More information1.1 Original Amplifier Professional construction well made. No markings. Based on R&H Feb Watt Amplifier.
4/03/2018 Australian 5W Combo Page 1 of 6 1. Summary Combo 5W Valve Amplifier and 8 Rola speaker. Unknown maker., Dec 2017. 1.1 Original Amplifier Professional construction well made. No markings. Based
More informationR 181 Replacement of the CIN 81
898 en -.007 / b ants This manual is to be given to the end user d on Roue polaire Main Stator Borne de so W V Y X Z C.T T.I. P Main output term R 8 Installation and maintenance 898 en -.007 / b We wish
More informationSelf-Contained Audio Preamplifier SSM2019
a FEATURES Excellent Noise Performance:. nv/ Hz or.5 db Noise Figure Ultra-low THD:
More informationADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W
ADC5000 SERIES AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications 60W, 125W and 250 W Input voltage 230/115 VAC voltages 12, 24, 36 or 48 VDC Statistical MTBF >3 000
More informationSilverMax Datasheet. QuickSilver Controls, Inc. NEMA 23 Servomotors.
SilverMax Datasheet NEMA 23 Servomotors QuickSilver Controls, Inc. www.quicksilvercontrols.com SilverMax Datasheet - NEMA 23 Servomotors 23 Frame Sizes: 23-3, 23-5, 23H-1, 23H-3, 23H-5 / Series: E, E3,
More informationPL 221 S-DIAS Pixel LED Module
PL 221 S-DIAS Pixel LED Module Date of creation: 13.03.2018 Version date: 16.05.2018 Article number: 20-018-221-E Publisher: SIGMATEK GmbH & Co KG A-5112 Lamprechtshausen Tel.: +43/6274/4321 Fax: +43/6274/4321-18
More informationFunction. Adjustment. Extra functions included. Modes. Housing
Electronic Electronic potentiometer potentiometer DATA DATA SHEET SHEET Function Replaces normal motor potentiometers Adjustment Integrating time (like variable gearboxes) Output start value Output end
More informationSelf contained servo drive CLDP Technical data sheet
voith.com Self contained servo drive CLDP Technical data sheet Advantages + + High energy efficiency + + High dynamics + + Oil free power pack and piping are not necessary + + Sensors used provide the
More informationRKP-1U Rack System. 2000~6000W 1U Distributed Power System. File Name:RKP-1U RACK SYSTEM-SPEC Sicherheit ID
Bauart gepruft Sicherheit egelma ge od o s be wac g www. tuv.com ID 2000000000 2000~6000W U Distributed Power System RKP-U Rack System File Name:RKP-U RACK SYSTEM-SPEC 206-07-26 2000~6000W U Distributed
More information