Level Measurement. 4/2 Overview

Size: px
Start display at page:

Download "Level Measurement. 4/2 Overview"

Transcription

1 Siemens AG 2015 /2 Overview Point level measurement /9 RF Capacitance switches /12 Pointek CLS100 /18 Pointek CLS200 Standard /27 Pointek CLS200 Digital /36 Pointek CLS200 Standard and Digital / Pointek CLS300 Standard /51 Pointek CLS300 Digital /57 Pointek CLS300 Standard and Digital /6 Pointek CLS500 /80 Pointek CLS Specials Vibrating switches /82 SITRANS LVL100 /88 SITRANS LVL200 /10 SITRANS LVS100 /107 SITRANS LVS200 Rotation paddle switches /116 SITRANS LPS200 Ultrasonic non-contacting switch /127 Pointek ULS200 Continuous level measurement /132 Ultrasonic Ultrasonic transmitters /136 SITRANS Probe LU /11 The Probe Ultrasonic controllers /1 SITRANS LUT00 series /152 MultiRanger 100/200 /156 HydroRanger 200 /160 SITRANS LU01 and LU02 /16 SITRANS LU10 /168 SITRANS LU AO Ultrasonic transducers /171 ST-H /17 EchoMax XRS-5 /178 EchoMax XPS Continuous level measurement (continued) Accessories for ultrasonic /185 EA aiming devices /187 FMS mounting brackets /189 TS-3 temperature sensor /191 Radar transmitters /19 SITRANS Probe LR /198 SITRANS LR200 /207 SITRANS LR200 Antennas /210 SITRANS LR200 Specials /213 SITRANS LR250 Horn Antenna /225 SITRANS LR250 Specials /226 SITRANS LR250 threaded PVDF antenna /232 SITRANS LR250 threaded PVDF Specials /233 SITRANS LR250 Flanged Encapsulated Antenna /22 SITRANS LR250 Flanged Encapsulated Specials /23 SITRANS LR250 Hygienic Encapsulated Antenna /268 SITRANS LR250 Hygienic Encapsulated Specials /269 SITRANS LR260 /27 SITRANS LR60 /279 SITRANS LR260/LR60 Specials /280 SITRANS LR560 /285 SITRANS LR560 Specials /286 Guided wave radar transmitters /289 SITRANS LG series Capacitance transmitters /32 SITRANS LC300 /338 SITRANS LC500 /361 SITRANS LC300 and LC500 Specials Communication /362 SmartLinx module /363 Dolphin Plus Software You can download all instructions, catalogs and certificates for SITRANS L free of charge: Siemens FI 01 June 2015

2 Product Overview Overview Application Device description Page Programming Software Point level measurement - RF Capacitance switches Powerful range of level switches Pointek CLS100/CLS200/CLS300/CLS500 suitable for a variety of industries CLS100: compact 2-wire inverse frequency shift capacitance switch for level detection in constricted spaces, interfaces, /12 SIMATIC PDM solids, liquids, slurries, and foam CLS200: a versatile inverse frequency shift capacitance /18 SIMATIC PDM level switch with optional rod/cable choices and configurable output, ideal for detection of liquids, solids, slurries, foam, and interfaces; digital version (with PROFIBUS PA) includes a display and provides additional diagnostic features CLS300: inverse frequency shift capacitance level switch / SIMATIC PDM with optional rod/cable choices and configurable output. It is ideal for detecting liquids, solids, slurries, foam and interfaces in demanding conditions where high pressure and temperatures are present; digital version (with PROFIBUS PA) includes a display and provides additional diagnostic features CLS500: inverse frequency shift capacitance level switch /6 SIMATIC PDM for detecting interfaces, solids, liquids, toxic and aggressive chemicals in critical conditions of high temperature and pressure; HART communication for remote commissioning Point level measurement - Vibrating switches Reliable vibrating point level SITRANS LVL100/LVL200 switches for liquid and slurry applications across all industries LVL100: compact vibrating level switch for use in liquid and slurry applications such as overflow, high, low, and /82 - demand level applications. Also ideal for dry run protection LVL200: advanced vibrating level switch for use in liquid and slurry applications. Suited for most hazardous area applications such as: overflow, high, low, demand, and dry run protection; can also be used for Functional Safety (SIL 2). Device suitable for use in accordance with IEC and IEC /88 - Reliable vibrating point level switches for bulk solids in a wide variety of applications at a competitive price SITRANS LVS100/LVS200 Vibrating point level switch designed to be impervious to external vibrations and to provide reliable performance in demanding bulk solids applications LVS100 LVS200 /10 / Point level measurement - Rotating paddle switch Reliable rotating point level SITRANS LPS200 /116 - switches for bulk solids in a wide Rotating paddle switch for detection of high, low, and demand levels for a wide variety of bulk solids industries. variety of applications at a competitive price Unique engineering provides long-lasting reliable performance /2 Siemens FI 01 June 2015

3 Product Overview Point level measurement - Ultrasonic switch Application Device description Page Programming Software Ultrasonic non-contacting switch with two switch points for level detection of bulk solids, liquids and slurries in a wide variety of industries Pointek ULS200 Rugged design, no moving parts, and virtually maintenance-free Transducer available in ETFE or PVDF copolymer and therefore inert to most chemicals /127 - Continuous measurement - Ultrasonic transmitters 2-wire loop powered ultrasonic SITRANS Probe LU transmitter for level, volume, and Continuous level measurement up to 12 m (0 ft) range flow monitoring of liquids in open channels, storage vessels Sonic Intelligence signal processing and simple process vessels Auto False-Echo Suppression /136 - Compact level transmitter with integrated transducer for accurate level measurement for liquid applications The Probe Simple, compact and competitively priced ultrasonic level transmitter in several versions for maximum versatility: - Three-wire system with alarm relay - Two-wire system with current loop /11 SIMATIC PDM Continuous measurement - Ultrasonic controllers The Siemens SITRANS LUT00 series controllers are compact, single point, long-range ultrasonic controllers for continuous level or volume measurement of liquids, slurries, and solids, and high accuracy monitoring of open channel flow. SITRANS LUT20/30/0 In addition to industry leading 1 mm (0.0 inch) accuracy, each of the three models in the series are compatible with our full range of EchoMax transducers and offer varying degrees of pump, alarm, and other control functionality, all from a very compact and easy-to-use interface. 1 mm accuracy HART communications Next Generation Sonic Intelligence /1 SIMATIC PDM Versatile short- to medium-range ultrasonic single- and dual-vessel level controller for virtually any application in a wide range of industries MultiRanger 100/200 Using non-contacting ultrasonic technology, the controller measures the level in short to medium range applications up to 15 m (50 ft) of solids, liquids, or slurries Auto False-Echo Suppression of false echoes /152 SIMATIC PDM Ultrasonic level controller for up to six pumps - control, differential control, and open channel flow monitoring HydroRanger 200 An economical, low-maintenance solution delivering control efficiency and productivity needed to meet today s exacting standards Auto False-Echo Suppression of false echoes /156 SIMATIC PDM Siemens FI 01 June 2015 /3

4 Product Overview Application Device description Page Programming Software Ultrasonic long-range level monitoring system for liquids and solids SITRANS LU01/LU02 SITRANS LU10 Automatic conversion of level into volume for standard or custom tank shapes Easy to install and program Optional fieldbus card, e.g. PROFIBUS DP /160 /16 Dolphin Plus Dolphin Plus Output module for SITRANS LU10 SITRANS LU AO SITRANS LU AO analog output module provides remote analog outputs for the measurement points of the SITRANS LU10 transceiver /168 - Continuous measurement - Ultrasonic transducers ST-H: ETFE or PVDF transducer for chemicals XRS-5: Standard transducer for applications to 8 m (26 ft) ST-H/EchoMax XRS-5 ST-H: The narrow design of the ST-H allows the sensor to be mounted using a 2 inch connection XRS-5: narrow beam angle of only 10, measuring range maximum 8 m (26 ft) for measurement of liquids, solids, and slurries /171 - /17 - Transducers for liquids and bulk solids XPS series: Hermetically sealed PVDF enclosure for chemical immunity EchoMax XPS XPS series offers versions for various distances up to 30 m (100 ft) and up to a maximum temperature of 95 C (203 F) /178 - Continuous measurement - Radar transmitters 2-wire, 6 GHz pulse radar level transmitter for continuous monitoring of liquids and slurries in storage vessels with nominal pressure and temperature, to a range of 20 m (66 ft) SITRANS Probe LR Uni-Construction polypropylene rod antenna standard Process Intelligence signal processing Auto False-Echo Suppression of false echoes /19 SIMATIC PDM / Siemens FI 01 June 2015

5 Product Overview Application Device description Page Programming Software 2-wire, 6 GHz pulse radar level transmitter for continuous monitoring of liquids and slurries in storage and process vessels including high temperature and pressure, to a range of 20 m (66 ft) SITRANS LR200 Program without opening the lid, even in hazardous areas, using patented infrared IS handheld programmer Special Uni-Construction hermetically sealed polypropylene rod antenna has integrated threaded connection Built-in alphanumeric display with support in four languages /198 SIMATIC PDM AMS SITRANS DTM 2-wire, 25 GHz pulse radar level transmitter for continuous monitoring of liquids and slurries in storage and process vessels including high temperature and pressure, to a range of 20 m (66 ft); antenna designs ideal for small vessels, low dielectric media, food & beverages and corrosive/aggressive media SITRANS LR250 Simple operation using the graphical local user interface (LUI) Plug-and-play setup using the intuitive Quick Start Wizard 25 GHz high frequency allows for small horn antennas and easy mounting in nozzles Process Intelligence signal processing for improved measurement reliability and Auto False-Echo Suppression of fixed obstructions /213 SIMATIC PDM AMS SITRANS DTM 2-wire, 25 GHz pulse radar level transmitter for continuous monitoring of solids and liquids up to 30 m (98. ft); ideal for measurement in extreme dust and high temperatures SITRANS LR260 Simple operation using the graphical local user interface (LUI) Plug-and-play setup using the intuitive Quick Start Wizard 25 GHz high frequency allows for small horn antennas and easy mounting in nozzles Process Intelligence signal processing for improved measurement reliability and Auto False-Echo Suppression of fixed obstructions /269 SIMATIC PDM -wire, 2 GHz FMCW radar level transmitter with extremely high signal-to-noise ratio and advanced signal processing for continuous monitoring of solids up to 100 m (328 ft); ideal for measurement in extreme dust SITRANS LR60 Process Intelligence for advanced signal processing and quick and easy adjustment Self-guided Quick Start Wizard for plug and play start-up 100 m (328 ft) range for long-range and difficult applications /27 SIMATIC PDM 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids in silos to a range of 100 m (329 ft) SITRANS LR560 Rugged stainless steel design 78 GHz high frequency provides very narrow beam, virtually no mounting nozzle noise, and optimal reflection from sloped solids Aimer option to direct beam to area of interest, such as draw point of cone Air purge connection is included for self-cleaning of extremely sticky solids Lens antenna is highly resistant to product build-up Local display interface (LDI) allows local programming and diagnostics /280 SIMATIC PDM AMS SITRANS DTM Siemens FI 01 June 2015 /5

6 Product Overview Application Device description Page Programming Software Continuous measurement - Guided wave radar transmitters Guided wave radar transmitters SITRANS LG20/250/260/270 for short- and medium-range level, level/interface, and volume measurement of liquids, slurries, and solids. Guided wave radar measurement The four LG models are unaffected by changes in process for up to 2 mm (0.08 inch) accuracy conditions, high temperatures and pressures, and provide a wide range of hygienic options. button programming for quick setup Measures accurately on materials with dielectric (dk) as low as 1. Measures level, level/interface, and volume of solids, slurries, and liquids Reliable level measurement on harsh applications with pressure up to 00 bar g (0 000 kpa) and temperatures as high as 50 C (82 F) /289 SIMATIC PDM Continuous level Capacitance transmitters For liquids and solids applications, ideal for standard industrial applications in chemical, hydrocarbon processing, food and beverage, and mining, aggregate and cement industries SITRANS LC300 Sophisticated, but easy-to-adjust microprocessor combined with field-proven probes Active shield technology ensures measurements are unaffected by vapors, product deposits, dust, and condensation /32 - Level and interface transmitter for extreme and critical process conditions, such as oil and liquid natural gas (LNG), toxic and aggressive chemicals and vapours SITRANS LC500 Equipped with the HART Smart protocol for remote setup and calibration Active shield technology ensures measurements are unaffected by vapors, product deposits, dust, and condensation /338 SIMATIC PDM Communications SmartLinx Module, Dolphin Plus software Optional communication modules, SmartLinx, provide direct digital connection to popular industrial fieldbus systems Dolphin Plus for quick and easy configuring, monitoring, tuning, and diagnostics of Siemens devices /362 - /363 - /6 Siemens FI 01 June 2015

7 Product Overview Selector Continuous Level Conditions Ultrasonic Radar Guided Wave Radar Measurement Capacitance Gravimetric Hydrostatic pressure Level Interface (liquid/liquid) Interface (liquid/solid) Volume Mass Flow (open channel) Level Applications Changing density Changing dielectric Aggressive chemicals Pressure/vacuum High temperature Cryogenic Turbulence Steam Hydrocarbon vapors/solvents Foam Build-up High viscosity Dust Solids powders Solids granules/pellets < 25 mm (1 inch) Solids >25mm(1inch) High angle of repose preferred condition dependent Siemens FI 01 June 2015 /7

8 Product Overview Selector Point Level Conditions Vibration Capacitance Paddle Ultrasonic Measurement Level Interface (liquid/liquid) Interface (liquid/solid) Volume Mass Flow (open channel) Level Applications Changing density Changing dielectric Aggressive chemicals Pressure/vacuum High temperature Cryogenic Turbulence Steam Hydrocarbon vapors/solvents Foam Build-up High viscosity Dust Solids powders Solids granules/pellets < 25 mm (1 inch) Solids >25mm(1inch) High angle of repose preferred condition dependent /8 Siemens FI 01 June 2015

9 Point level measurement - RF Capacitance switches RF Capacitance Overview Mode of operation Introduction Common Terms Inverse frequency shift capacitance point level and material detection switches are designed to withstand the harsh environ- Capacitance ments of high pressure and high temperature applications. Inverse Frequency Technology Siemens inverse frequency shift capacitance devices incorporate a unique frequency-based approach to level measurement. The capacitance units monitor the effect of capacitance based Capacitor on frequency change. The relationship between capacitance and frequency is inverse. Because small level changes result in a large frequency change, the result is excellent resolution and accuracy. Principle of Operation Inverse frequency shift capacitance devices require two components: a reference electrode of a variable capacitor and the measurement electrode. In capacitive level measurement, the Dielectric constant environment (typically the vessel wall) acts as the reference electrode, while the probe supplies the measurement electrode. The dielectric is composed of the vessel contents and, if the measurement electrode is insulated, the insulating layer. Operating principles Dielectric = contents plus insulation (non-conductive contents) Dielectric = insulation (conductive contents) The property of a system of conductors and dielectrics that permits the storage of electricity when a potential difference exists between the conductors. Its value is expressed as the ratio of a quantity of electricity to a potential difference and the unit is a Farad. A device in a circuit that has the potential to store an electric charge. Typically a capacitor has two conductors or electrodes separated by a layer of a non-conducting material called a dielectric. With the conductors on opposite sides of the dielectric layer oppositely charged by a source of voltage, the electrical energy of the charged system is stored in the polarized dielectric. The ability of a dielectric to store electrical potential energy under the influence of an electric field. This is measured by a ratio which compares the capacitance of a condenser with the material as dielectric to its capacitance with a vacuum/dry air as dielectric: the dielectric constant of air is 1. Active shield The portion of the probe isolated from the active measurement section. The sensor signal is connected to the active shield portion of the probe, eliminating the electrical potential difference between the shield and the measurement section. So, the shield portion of the probe near the process connection is not affected by changes in vapor concentration, material buildup, dust, or condensation. Internal vessel wall Probe dia. (Insulation) Probe sleeve Internal vessel diameter Inverse frequency shift capacitance operation Capacitance is affected by the surface area of the electrodes, the separation distance between the electrodes and the dielectric constant of the vessel contents. The dielectric constant is the measure of a material s ability to store energy. The relative dielectric constant of air (vacuum) is 1; all other materials have a higher value. Siemens FI 01 June 2015 /9

10 Point level measurement - RF Capacitance switches RF Capacitance Technical specifications Point Criteria Pointek CLS100 Pointek CLS200 Pointek CLS300 Pointek CLS500 Typical applications Liquids, slurries, powders, granules, applications in constricted spaces Max. length including sensor Process temperature (Temperature ratings are pressure dependent. See Pressure/Temperature curves for respective product.) Process pressure (Pressure ratings are temperature dependent. See Pressure/Temperature curves for respective product.) Output Communications Power Specifications Approvals Liquids, slurries, powders, granules, foam, food, and pharmaceuticals, petrochemicals 100 mm ( inch) Rod: 5.5m (18ft) Cable: up to 30 m (98 ft) Stainless steel process connection: C ( F) Fully Synthetic (PPS process connection): C ( F) Up to 10 bar g (16 psi g) Stainless steel cable or enclosure version:... 20/20... ma 2-wire current loop Solid-state output Fully-synthetic version (PPS) Relay output Standard: V DC Intrinsically Safe (Stainless steel version only): V DC Stainless steel cable or enclosure version: CE, CSA, FM, ATEX, RCM, Lloyds Register, WHG Fully-synthetic version (PPS): CSA, FM C ( F) With thermal isolator: C ( F) Rod versions: Up to 25 bar g (365 psi g) Cable version: Up to 10 bar g (16 psi g) Standard: 1 SPDT Form C relay, solidstate switch Digital: Solid-state switch included Standard: 3 LED indicators Digital: PROFIBUS PA; SIMATIC PDM compatible Standard: V AC/DC, Hz, 2 W max. Digital: Bus voltage: V DC, IS version V DC Current consumption: 12.5 ma CSA, FM, CE, ATEX, RCM, Lloyds Register, WHG, Vlarem II Liquids, slurries, powders, granules, relatively high pressure and temperature, hazardous areas Rod: 1m (0inch) Cable: 25 m (82 ft) C ( F) HT version: C ( F) Water in oil level, foam or liquid/ foam level, glycol regenerators, high-pressure coalescers Rod: 1m (0inch) C ( F) HT version: C ( F) Up to 35 bar g (511 psi g) Up to 150 bar g (2 175 psi g) Standard: 1 SPDT Form C relay, solid-state switch Digital: Solid-state switch included Standard: 3 LED indicators Digital: PROFIBUS PA; SIMATIC PDM compatible Standard: V AC/DC, Hz, 2 W max. Digital: Bus voltage: V DC, IS version V DC Current consumption: 12.5 ma CSA, FM, CE, ATEX, RCM, Lloyds Register, WHG, Vlarem II... 20/20... ma 2-wire current loop Solid-state switch HART, SIMATIC PDM compatible V DC ma/ ma (2-wire current loop) CE, CSA, FM, ATEX, RCM, Lloyds Register, Bureau Veritas, Current Signaling according to NAMUR NE 3 /10 Siemens FI 01 June 2015

11 Point level measurement - RF Capacitance switches RF Capacitance Application Capacitance Application Questionnaire Customer information Contact: Company: Prepared By: Date: Address: Notes on the Application: City: Zip/Postal Code: Country: Phone: ( ) Fax: ( ) Tank/Vessel Information (Supply sketch where possible) Sketch attached Type: Storage Process Separator FPSO (Floating Processing Storage and Offloading) Tank top: Open Tank bottom: Sloped Mounting: Top Mount Process Data Flat Flat Side Mount Conical Parabolic Tank construction: Metallic Non-metallic Pressure: Normal: Agitated top, bottom or side Maximum (relief): Conical Parabolic Pipe Mount Dimensions: Height: Width/Diameter: Critical Information Nozzle Length: Nozzle Diameter: m/ft m/ft cm/inch cm/inch Material being measured: Liquid Solid Slurry Material temperature: Norm: C/ F Max: C/ F Measurement type: Point level Continuous level Constant dielectric: No Yes DK Value Interface level Upper material: Lower material: DK Value DK Value Process pressure: Min. Max. Atmospheric steam: No Yes Coating build-up: No Yes Conductive material: No Yes DK Value Installation Power available: (indicate all that apply) Outputs required: ma Relay Solid state Products recommended: Communications HART / ma PROFIBUS PA Siemens Milltronics Process Instruments Inc. Update 03/2015 Capacitance Application Questionnaire Siemens FI 01 June 2015 /11

12 Point level measurement - RF Capacitance switches Pointek CLS100 Overview Configuration Installation Standpipes 50 (2) 20 (0.79) max. Pointek CLS100 is a compact 2-wire inverse frequency shift capacitance switch for level and material detection in constricted spaces, interfaces, solids, liquids, slurries and foam, with the ability to tune out build-up on probe. Wall restriction Benefits Easy installation with verification by built-in LED Low maintenance with no moving parts Sensitivity adjustment Integrated cable or PBT enclosure versions available Intrinsically Safe, Dust Ignition Proof, and General Purpose options available 50 (2) 50 (2) min. Application Pointek CLS100 s short insertion length of 100 mm ( inch) and versatility in various applications and in vessels or pipes makes it a good replacement for traditional capacitance sensors. Its advanced tip-sensing technology provides accurate, repeatable switchpoint performance. The PPS (Polyphenylene sulfide) probe [optional PVDF (Polyvinylidene Fluoride)] is chemically resistant with an effective process operating temperature range from -30 to +100 C (-22 to +212 F) (7ML5501), and -10 to +100 C (1 to 212 F) (7ML5610). The fully potted design ensures reliability in a vibrating environment such as agitated tanks up to g. When used with a SensGuard protection cover, the CLS100 is protected from shearing, impact, and abrasion in tough primary processes. The Pointek CLS100 is available in three versions. The integral cable version has a stainless steel process connection and probe options of PPS or PVDF. The fully synthetic version has a thermoplastic polyester enclosure with a PPS process connection combined with a PPS probe. The standard enclosure version has a thermoplastic polyester enclosure with a stainless steel process connection in combination with a PPS or PVDF probe. Key Applications: liquids, slurries, powders, granules, food and pharmaceuticals, chemicals, hazardous areas Pointek CLS100 installation, dimensions in mm (inch) /12 Siemens FI 01 June 2015

13 Point level measurement - RF Capacitance switches Pointek CLS100 Technical specifications Mode of operation Measuring principle Input Measured variable Stainless steel process connection (integral cable or enclosure version) (7ML5501) Inverse frequency shift capacitive level detection Change in picofarad (pf) Fully synthetic process connection (enclosure version only) (7ML5610) Inverse frequency shift capacitive level detection Change in picofarad (pf) Output Output signal Alarm output... 20/20... ma 2-wire loop... 20/20... ma 2-wire loop Switch output 1) Solid-state: 30 V DC/30 V AC, max. 82 ma Max. switching voltage: 60 V DC/30 V AC Max. switching current: 1 A Fail-safe mode Min. or max. Min. or max. Accuracy Repeatability 2 mm (0.08 inch) 2 mm (0.08 inch) Rated operating conditions 2) Installation conditions Location Indoor/outdoor Indoor/outdoor Ambient conditions Ambient temperature C ( F) C ( F) Installation category I I Pollution degree Medium conditions Relative dielectric constant ε r Min. 1.5 Min. 1.5 Process temperature C ( F) C ( F) Pressure (vessel) bar g ( psi g), nominal 2) bar g ( psi g), nominal Degree of protection - Enclosure version IP68/Type /NEMA IP68/Type /NEMA - Integral cable version IP65/Type /NEMA Not applicable Cable inlet ½" NPT (M20x1.5 optional) ½" NPT (M20x1.5 optional) Design Enclosure/Integral cable Fully synthetic version version Material Body (Enclosure version) Thermoplastic polyester Thermoplastic polyester Lid (Enclosure version) Transparent thermoplastic polycarbonate (PC) Transparent thermoplastic polycarbonate (PC) Integrated cable body (Integral cable version) 316L stainless steel Not applicable Sensor length (nominal) 100 mm ( inch) 100 mm ( inch) Process connection material of probe/wetted parts 3) Connection (Enclosure version) Connection (Integral cable version) Process connection Connection: 316L stainless steel; Process seal: FKM (optional FFKM); Sensor: PPS (optional PVDF) ) Internal 5-point terminal block, ½" NPT wiring entrance, M20x1.5 optional conductors, 1 m (3.3 ft), 0.5 mm² (22 AWG), shielded, polyester jacket ¾" NPT [(Taper), ANSI/ASME B1.20.1] R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] G 1" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] PPS process connection and PPS sensor (Uni-Construction) Removable internal 5-point terminal block, ½" NPT wiring entrance, M20 x 1.5 optional Not applicable ¾" NPT [(Taper), ANSI/ASME B1.20.1] R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] Power supply Standard V DC V DC Intrinsically Safe V DC (Intrinsically Safe barrier required) Not applicable Certificates and approvals Stainless steel process connection (integral cable or enclosure version) (7ML5501) Fully synthetic process connection (enclosure version only) (7ML5610) General: CE, CSA, FM, General: CSA, FM RCM Marine: Lloyds Register of Shipping, categories ENV1, ENV2, and ENV5 Dust Ignition Proof (barrier required): CSA/FM Class II and III, Div. 1, Groups E, F, G T Intrinsically Safe (barrier required): CSA/FM Class I, II and III, Div. 1, Groups A, B, C, D, E, F, G T ATEX II 1 GD 1/2GD EEx ia IIC T to T6 T107 C Overfill protection: WHG (Germany) 1) When synthetic process connection version (7ML5610) is used in wet locations, switching voltage of the relay is limited to 35 V DC/16 V AC. 2) When operation is in areas classified as hazardous, observe restrictions according to relevant certificate. See also Pressure/Temperature curves on page 5/13. 3) For Caustic Materials please contact ceg.smpi@siemens.com for alternative O-rings ) When FFKM O-ring (Option A22) is selected, process temperature is restricted to -20 C (- F). Siemens FI 01 June 2015 /13

14 Point level measurement - RF Capacitance switches Pointek CLS100 Pointek CLS100, stainless steel process connection Compact 2-wire inverse frequency shift capacitance switch for level and material detection in constricted spaces, interfaces, solids, liquids, slurries and foam, with the ability to tune out build-up on probe. 7ML Click on the for the online configuration in the PIA Life Cycle Portal. Process connection ¾" NPT [(Taper), ANSI/ASME B1.20.1] A R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] E G 1" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] J Approvals General Purpose: CE, CSA, FM, RCM A CSA/FM Class I, II and III, Div. 1, Groups A, B, C, D, C E, F, G T; ATEX II 1 GD 1/2GD EEx ia IIC T to T6 T107 C 1) CSA/FM Class II and III, Div. 1, Groups E, F, G 1) G Device version Integral cable version (PPS probe) 1 Enclosure version (PPS probe), ½" NPT cable inlet 3 Integral cable version with PVDF probe body 5 Enclosure version with PVDF probe body 6 (½" NPT cable inlet) Enclosure version (PPS probe), M20 x 1.5 cable 7 inlet Enclosure version with PVDF probe body, M20 x 1.5 cable inlet 8 Overfill protection Not required 0 Required 1 1) Barrier or Intrinsically Safe power supply required for Intrinsically Safe protection We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 9/5 in the appendix. Further designs Please add "-Z" to and specify Order code(s). Order code Acrylic coated, stainless steel tag [13 x 5 mm Y17 (0.5 x 1.75 inch)]: Measuring-point number/ identification (max. 20 characters) specify in plain text FFKM seal O-ring 1) A22 Inspection Certificate Type 3.1 per EN 1020 C12 Operating Instructions Quick start manual, multi-language A5E Note: due to ATEX regulations one Quick start manual is included with every product. This device is shipped with the Siemens Milltronics manual DVD containing ATEX Quick Starts and Operating Instructions. 1) See Temperature restriction on page /16 We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 9/5 in the appendix. Accessories SensGuard, ¾" NPT (PPS) Only available for CLS100 with ¾" NPT thread SensGuard, R 1" (BSPT) (PPS) Only available for CLS100 with ¾" NPT thread Tag, stainless steel, 12 x 5 mm (0.7 x 1.77 inch), one text line, suitable for enclosures Siemens Intrinsically Safe Barrier (DC powered), ATEX II 1 G EEx ia ½" NPT cable gland, nickel plated brass, fits cable diameter mm ( inch) C ( F), IP68 (General Purpose) M20 x 1.5 cable gland, PA polyamide, ATEX II 2G EEx e II, fits cable diameter mm ( inch), C ( F), IP68 (General Purpose) Pointek CLS100, PPS process connection Compact 2-wire inverse frequency shift capacitance switch for level and material detection in constricted spaces, interfaces, solids, liquids, slurries and foam, with the ability to tune out buildup on probe. Click on the for the online configuration in the PIA Life Cycle Portal. Process connection (PPS) ¾" NPT [(Taper), ANSI/ASME B1.20.1] (PPS probe body) R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] (PPS probe body) 7ML1830-1DL 7ML1830-1DM 7ML1930-1AC 7NG12-0AA00 7ML1830-1JA 7ML1830-1JC 7ML Approvals General Purpose: CSA, FM D Versions/Options Enclosure version, PPS process connection, ½" NPT cable inlet Enclosure version, PPS process connection, M20 x 1.5 A B 1 2 Overfill protection Not required 0 Required 1 Further designs Please add "-Z" to and specify Order code(s). Acrylic coated, stainless steel tag [13 x 5 mm (0.5 x 1.75 inch)]: Measuring-point number/ identification (max. 20 characters) specify in plain text FFKM seal O-ring 1) Inspection Certificate Type 3.1 per EN 1020 Operating Instructions Quick start manual, multi-language Note: due to ATEX regulations one Quick start manual is included with every product. This device is shipped with the Siemens Milltronics manual DVD containing ATEX Quick Starts and Operating Instructions. Accessories SensGuard, ¾" NPT (PPS) Only available for CLS100 with ¾" NPT thread SensGuard, R 1" (BSPT) (PPS) Only available for CLS100 with ¾" NPT thread Tag, stainless steel, 12 x 5 mm, (0.7 x 1.77 inch) one text line, suitable for enclosures 1) See Temperature restriction on page /16 Order code Y17 A22 C12 A5E ML1830-1DL 7ML1830-1DM 7ML1930-1AC We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 9/5 in the appendix. /1 Siemens FI 01 June 2015

15 Point level measurement - RF Capacitance switches Pointek CLS100 Options Optional SensGuard Internal thread ¾" NPT 32 (1.26) Process connection ¾" NPT Process connection R 1" (BSPT) 91 (3.6) 70 (2.75) 91 (3.6) 32 (1.26) 70 (2.75) Optional SensGuard, dimensions in mm (inch) Siemens FI 01 June 2015 /15

16 Point level measurement - RF Capacitance switches Pointek CLS100 Characteristic curves Pressure/temperature curve CLS100 Threaded process connections (7ML5501) Permitted operating pressures P 30 bar (35 psi) 20 bar (290 psi) Atmospheric -1 bar (-1.5 psi) -150 ºC (-238 ºF) -100 ºC (-18 ºF) 10 bar (15 psi) -22 ºF 1 ºF (-30 ºC) (-10 ºC) -50 ºC (-58 ºF) 100 ºF (38 ºC) 200 ºF (93 ºC) 0 ºC RT 50 ºC 100 ºC (32 ºF) (122 ºF) (212 ºF) 300 ºF (19 ºC) 150 ºC (302 ºF) 00 ºF (20 ºC) 200 ºC (392 ºF) -29 ºC (-20 ºF) Permitted operating temperature T Example: Permitted operating pressure = 10 bar (15 psi) at 75 C Pointek CLS100 Process Pressure/Temperature derating curves Dimensional drawings Integral cable version Enclosure version 80 (3.2) Ground post Power LED (green) Sensitivity trimpot Cable Ø 5 (0.2) Trimpot cap 36 (1.) nominal* Cable relief Output status LED (red) Sensor status LED (yellow) Power LED (green) Sensitivity trimpot Sensor status LED (yellow) Output status LED (red) (2.6) Cable inlet ½" NPT (optional M20x1.5) Terminal block Ground lug 120 (.7) 50 (2.0) 98 (3.9) nominal Process connection Process connection 98 (3.9) nominal 72.5 (2.9) 120 (.7) 20 (8.0) *Some G thread configurations deviate from this size. Pointek CLS100, dimensions in mm (inch) /16 Siemens FI 01 June 2015

17 Point level measurement - RF Capacitance switches Pointek CLS100 Schematics Integral Cable Version - Non Intrinsically Safe only LOW/HIGH Alarm White White Black Red Polarity as required for desired operation V DC /20 ma Loop Alarm White White Black Rmax = Vsupply - 10 V 20 ma Solid State Switch Version Red White White Black V supply V DC Solid state switch, 30 V DC/AC (peak) 82 ma (max) Red V supply V DC Enclosure and Fully Synthetic Version Terminal operations Cable equivalent ma current loop (+V or -V) Red wire ma current loop (+V or -V) Black wire ground Cable shield Solid state switch/relay* White wire Solid state switch/relay* White wire Note: * Switch/relay normally open in unpowered state * Relay not available on Pointek CLS100 IS version (7ML5501) When driving an inductive load (for example, an external relay), a protection diode must be connected in the correct polarity to prevent possible switch damage due to inductive spikes generated by switching the inductor (please refer to instruction manual). Intrinsically Safe Models - please follow local regulations and area classifications; refer to instruction manual for more details. Pointek CLS100 connections Siemens FI 01 June 2015 /17

18 Point level measurement - RF Capacitance switches Pointek CLS200 - Standard Overview Configuration Installation Pointek CLS200 (standard version) is a versatile inverse frequency shift capacitance level and material detection switch with optional rod/cable choices and configurable output. CLS200 is ideal for detection of liquids, solids, slurries, foam and interfaces and has the ability to tune out build-up on the probe. Benefits Potted construction protects signal circuit from shock, vibration, humidity and/or condensation High chemical resistance Level detection independent of tank or pipe earth reference Insensitive to product buildup due to high frequency oscillation 3 LED indicators for sensor status, output status, and power Keep unit out of path of falling material, or protect probe from falling material. Avoid areas where material build up occurs. Application Pointek CLS200 standard version has 3 LED indicators with basic relay and solid-state switch alarms. Universal switch for solids/liquids and interface. The power supply is galvanically isolated and accepts a wide range of voltages (12 to 250 V AC/DC). When used with thermal isolator, the stainless steel and PPS (PVDF optional) materials used in the probe construction provide a temperature rating up to 125 C (257 F) on the process wetted portion of the probe. The switch responds to any material with a dielectric constant of 1.5 or more by detecting a change in oscillating frequency, and it can be set to detect before contact or on contact with the probe. The CLS200 operates independently of the tank wall or pipe so it does not require an external reference electrode for level detection in a non-conductive vessel such as concrete or plastic (EMC regulations applicable in some regions). Key Applications: liquids, slurries, powders, granules, pressurized applications, hazardous areas Install probe at least 50 (2) from tank wall. Pointek CLS200 installation, dimensions in mm (inch) Min. 50 (2) /18 Siemens FI 01 June 2015

19 Point level measurement - RF Capacitance switches Pointek CLS200 - Standard Technical specifications Mode of operation Measuring principle Inverse frequency shift capacitive level detection Input Measured variable Change in picofarad (pf) Output Output signal Relay output 1 SPDT Form C relay - Max. contact voltage 30 V DC 250 V AC - Max. contact current 5 A DC 8 AAC - Max. switching capacity 150 W DC VA AC - Time delay (ON and/or OFF) s Solid-state output -Output Galvanically isolated -Protection Against reversed polarity (bipolar) - Max. switching voltage 30 V DC 30 V peak AC - Max. load current 82 ma - Voltage drop < 1 V, typical at 50 ma - Time delay (pre or post switching) s Rated operating conditions 1) Installation conditions Location Indoor/outdoor Ambient conditions Ambient temperature C ( F) 2) Installation category II Pollution degree Medium conditions Liquids, bulk solids, slurries and interfaces Relative dielectric constant ε r Min. 1.5 Process temperature - Without thermal isolator C ( F) 2) - With thermal isolator C ( F) Process pressure (rod version) bar g ( psi g) (nominal) Process pressure (cable version) 3) bar g ( psi g) (nominal) Process pressure (sliding coupling bar g version) ( psi g) (nominal) Electromagnetic Compatibility To comply with CE EMC regulations (where applicable); the CLS200 should be installed per the instruction manual. Design Material Enclosure Epoxy-coated aluminum with gasket Optional thermal isolator 316L stainless steel Connection Removable terminal block, max. 2.5 mm² Degree of protection IP65/Type /NEMA (optional IP68) Cable inlet 2 x M20x1.5 thread (option: 2 x ½" NPT conduit entry including 1 plugged entry) Power supply V AC/DC, Hz max. 2 W Certificates and approvals General Purpose CSA, FM, CE, RCM Dust Ignition Proof ATEX II 1/2 D T100 C Flameproof Enclosure With IS Probe ATEX II 1 G EEx d[ia] IIC T6... T ATEX II 1/2 D T100 C Dust Ignition Proof with IS Probe CSA/FM Class II, Div. 1, Groups E, F, G CSA/FM Class III T Explosion Proof Enclosure With IS Probe Marine Overfill Protection Others CSA/FM Class I, Div. 1, Groups A, B, C, D CSA/FM Class II, Div. 1, Groups E, F, G CSA/FM Class III T Lloyds Register of Shipping, Categories ENV1, ENV2 and ENV5 WHG (Germany) VLAREM II Pattern Approval (China) 1) When operation is in areas classified as hazardous, observe restrictions according to relevant certificate. See also Pressure/Temperature curves on page /37. 2) Thermal isolator is used if process connection temperature exceeds 85 C (185 F) 3) Pressure rating of process seal is temperature dependent. See Pressure/ Temperature curves on page /37. Siemens FI 01 June 2015 /19

20 Point level measurement - RF Capacitance switches Pointek CLS200 - Standard Design: Probe Rod version Sanitary version Cable version Sliding Coupling version Max. length mm ( inch) mm ( inch) mm ( inch) liquids and slurries mm ( inch) solids (under loads) mm ( inch) Process connection R ¾", 1", 1¼", 1½" [(BSPT), 1½", 2" sanitary fitting clamp R ¾", 1", 1¼", 1½" [(BSPT), R ¾", 1", 1¼", 1½" [(BSPT), EN 10226/PT (JIS-T), 316L stainless steel EN 10226/PT (JIS-T), EN 10226/PT (JIS-T), JIS B 0203] JIS B 0203] JIS B 0203] ¾", 1", 1¼", 1½" NPT [(Taper), ANSI/ASME B1.20.1] G ¾", 1", 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] 316L stainless steel ASME/EN flange ¾", 1", 1¼", 1½" NPT [(Taper), ANSI/ASME B1.20.1] G ¾", 1", 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] 316L stainless steel ASME/EN flange ¾", 1", 1¼", 1½" NPT [(Taper), ANSI/ASME B1.20.1] G ¾", 1", 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] Extension material 316L stainless steel 316L stainless steel optional PFA coated 1) 316L stainless steel Fluoroethylene propylene (FEP) cable with stainless steel core Sensor wetted parts PPS (optional PVDF) PPS (optional PVDF) PPS (optional PVDF) PPS (optional PVDF) O-ring seal material FKM (optional FFKM) 2) FKM (optional FFKM) 2) FKM (optional FFKM) 2) FKM (optional FFKM) 2) Thermal isolator 3) Optional Optional Optional Optional Extension User selected length User selected length Cable extension User selected length 1) PFA coating (7ML563 and 7ML56) has 120 micron thickness. 2) For Caustic Materials please contact ceg.smpi@siemens.com for alternative O-rings 3) Thermal isolator is used if process connection temperature exceeds 85 C (185 F). /20 Siemens FI 01 June 2015

21 Point level measurement - RF Capacitance switches Pointek CLS200 - Standard - Rod Version with Threaded or Flanged process connection Versatile inverse frequency shift capacitance level and material detection switch with optional rod/ cable choices and configurable output. CLS200 is ideal for detection of liquids, solids, slurries, foam, and interfaces, and has the ability to tune out buildup on the probe. Click on the for the online configuration in the PIA Life Cycle Portal. Process connection Threaded, 316L stainless steel ¾" NPT [(Taper), ANSI/ASME B1.20.1] 0 A 1" NPT [(Taper), ANSI/ASME B1.20.1] 0 B 1¼" NPT [(Taper), ANSI/ASME B1.20.1] 0 C 1½" NPT [(Taper), ANSI/ASME B1.20.1] 0 D R ¾" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] 1 A R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] 1 B R 1½" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] 1 D G ¾" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] 3 A G 1" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] 3 B G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), 3 D JIS B 0202] Welded flange, 316L stainless steel, raised face 1" ASME, 150 lb 5 A 1" ASME, 300 lb 5 B 1" ASME, 600 lb 5 C 1½" ASME, 150 lb 5 D 1½" ASME, 300 lb 5 E 1½" ASME, 600 lb 5 F 2" ASME, 150 lb 5 G 2" ASME, 300 lb 5 H 2" ASME, 600 lb 5 J 3" ASME, 150 lb 5 K 3" ASME, 300 lb 5 L 3" ASME, 600 lb 5 M " ASME, 150 lb 5 N " ASME, 300 lb 5 P " ASME, 600 lb 5 Q Welded flange, 316L stainless steel, Type A flat faced DN 25, PN 16 6 A DN 25, PN 0 6 B DN 0, PN 16 6 C DN 0, PN 0 6 D DN 50, PN 16 6 E DN 50, PN 0 6 F DN 80, PN 16 6 G DN 80, PN 0 6 H DN 100, PN 16 6 J DN 100, PN 0 6 K (Note: Flange bolting patterns and facings dimensionally correspond to the applicable ASME B16.5 or EN standard.) Probe length (length from flange face) (threaded lengths include process thread) Note: No Y01 needed in Order code for standard lengths Compact [threaded 120 mm (.72 inch), A Flanged 98 mm (3.86 inch)] Extended rod, 250 mm (9.8 inch) B Extended rod, 350 mm (13.78 inch) C Extended rod, 500 mm (19.69 inch) D Extended rod, 750 mm (29.53 inch) E Extended rod, mm (39.37 inch) F Extended rod, mm (9.21 inch) G Extended rod, mm (53.15 inch) H Extended rod, mm (59.06 inch) J Extended rod, mm (68.90 inch) K Extended rod, mm (78.7 inch) L 7ML Pointek CLS200 - Standard - Rod Version with Threaded or Flanged process connection Versatile inverse frequency shift capacitance level and material detection switch with optional rod/ cable choices and configurable output. CLS200 is ideal for detection of liquids, solids, slurries, foam, and interfaces, and has the ability to tune out buildup on the probe. Pointek CLS200 - Standard Add Order code Y01 and plain text: "Insertion length... mm" Extended rod, mm ( inch) M Extended rod, mm N ( inch) Extended rod, mm P ( inch) Extended rod, mm Q ( inch) Extended rod, mm R ( inch) Extended rod, mm S ( inch) Thermal isolator Without thermal isolator 0 With thermal isolator [for process connection 1 temperatures over 85 C (185 F)] Remote mount electronics and mounting bracket With 2 m (79 inch) of cable 1) 2 With 5 m (197 inch) of cable 1) 3 Wetted seals FKM 0 FFKM [for process temperatures above -20 C (- F)] 1 Probe material 316L stainless steel with PPS probe body 0 316L stainless steel with PVDF probe body 1 Approvals Dust Ignition Proof: C CE, RCM, ATEX II 1/2 D T100 C Flameproof Enclosure with IS Probe: D CE, RCM, ATEX II 1 G EEx d[ia] IIC T6... T, ATEX II 1/2 D T100 C Flameproof Enclosure with IS Probe, E with WHG approval: CE, RCM, ATEX II 1/2 G EEx d[ia] IIC T6... T, ATEX II 1/2 D T100 C Dust Ignition Proof with IS Probe: F CSA/FM Class II, Div. 1, Groups E, F, G CSA/FM Class III T Explosion Proof Enclosure with IS Probe: G CSA/FM Class I, Div. 1, Groups A, B, C, D CSA/FM Class II, Div. 1, Groups E, F, G CSA/FM Class III T General Purpose (CSA, FM) H General Purpose (CE, RCM) J General Purpose (CSA, FM, CE, RCM) K with WHG approval Enclosure and lid Aluminum epoxy coated 2 x ½" NPT via adapter - cable inlet, IP65 A 2 x M20 x 1.5 cable inlet IP65 B 2 x ½" NPT via adapter - cable inlet, IP68 C 2 x M20 x 1.5 cable inlet IP68 D 1) Available with Approvals options F... H 7ML We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 9/5 in the appendix. Siemens FI 01 June 2015 /21

22 Point level measurement - RF Capacitance switches Pointek CLS200 - Standard Order code Further designs Please add "-Z" to and specify Order code(s). Total insertion length: enter the total insertion length Y01 in plain text description Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Y15 Measuring-point number/identification (max. 27 characters) specify in plain text Manufacturer's test certificate: M to DIN 55350, C11 Part 18 and ISO 9000 Inspection Certificate Type 3.1 per EN 1020 C12 SIL/IEC Declaration of Conformity C20 [SIL 2 (overspill)] Operating Instructions Note: The Operating Instructions should be See page /36 ordered as a separate line on the order. This device is shipped with the Siemens Milltronics manual DVD containing the ATEX Quick Start and manual library. Accessories See page /36 We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 9/5 in the appendix. Pointek CLS200 - Standard - Cable Version with Threaded or Flanged process connection Versatile inverse frequency shift capacitance level and material detection switch with optional rod/ cable choices and configurable output. CLS200 is ideal for detection of liquids, solids, slurries, foam, and interfaces, and has the ability to tune out buildup on the probe. Click on the for the online configuration in the PIA Life Cycle Portal. Process connection Threaded, 316L stainless steel ¾" NPT [(Taper), ANSI/ASME B1.20.1] 0 A 1" NPT [(Taper), ANSI/ASME B1.20.1] 0 B 1¼" NPT [(Taper), ANSI/ASME B1.20.1] 0 C 1½" NPT [(Taper), ANSI/ASME B1.20.1] 0 D R ¾" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] 1 A R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] 1 B R 1½" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] 1 D G ¾" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] 3 A G 1" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] 3 B G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), 3 D JIS B 0202] Welded flange, 316L stainless steel, raised face 1" ASME, 150 lb 5 A 1" ASME, 300 lb 5 B 1" ASME, 600 lb 5 C 1½" ASME, 150 lb 5 D 1½" ASME, 300 lb 5 E 1½" ASME, 600 lb 5 F 2" ASME, 150 lb 5 G 2" ASME, 300 lb 5 H 2" ASME, 600 lb 5 J 3" ASME, 150 lb 5 K 3" ASME, 300 lb 5 L 3" ASME, 600 lb 5 M " ASME, 150 lb 5 N " ASME, 300 lb 5 P " ASME, 600 lb 5 Q Welded flange, 316L stainless steel, Type A flat faced DN 25, PN 16 6 A DN 25, PN 0 6 B DN 0, PN 16 6 C DN 0, PN 0 6 D DN 50, PN 16 6 E DN 50, PN 0 6 F DN 80, PN 16 6 G DN 80, PN 0 6 H DN 100, PN 16 6 J DN 100, PN 0 6 K (Note: Flange bolting patterns and facings dimensionally correspond to the applicable ASME B16.5 or EN standard.) Probe length (length from flange face) (threaded lengths include process thread) Note: No Y01 needed in Order code for standard lengths Extended cable, mm ( inch), length A can be determined by customer on assembly 1) Extended cable, mm ( inch), length B can be determined by customer on assembly 1) Add Order code Y01 and plain text: "Insertion length... mm" Extended cable, mm ( inch) C Extended cable, mm ( inch) D Extended cable, mm ( inch) E Extended cable, mm ( inch) F Extended cable, mm ( inch) G Extended cable, mm ( inch) H 7ML /22 Siemens FI 01 June 2015

23 Point level measurement - RF Capacitance switches Pointek CLS200 - Standard Pointek CLS200 - Standard - Cable Version with Threaded or Flanged process connection Versatile inverse frequency shift capacitance level and material detection switch with optional rod/ cable choices and configurable output. CLS200 is ideal for detection of liquids, solids, slurries, foam, and interfaces, and has the ability to tune out buildup on the probe. Thermal isolator Without thermal isolator 0 With thermal isolator [for process connection temperatures over 85 C (185 F)] 1 Remote mount electronics and mounting bracket With 2 m (79 inch) of cable 2) 2 With 5 m (197 inch) of cable 2) 3 Wetted seals FKM and PTFE 0 FFKM and PTFE [for process temperatures above 1-20 C (- F)] Probe material FEP jacketed cable with PPS probe body 0 FEP jacketed cable with PVDF probe body 1 Approvals Dust Ignition Proof: C CE, RCM, ATEX II 1/2 D T100 C Flameproof Enclosure with IS Probe: D CE, RCM, ATEX II 1 G EEx d[ia] IIC T6...T, ATEX II 1/2 D T100 C Flameproof Enclosure with IS Probe, E with WHG approval: CE, RCM, ATEX II 1/2 G EEx d[ia] IIC T6...T, ATEX II 1/2 D T100 C Dust Ignition Proof with IS Probe: F CSA/FM Class II, Div. 1, Groups E, F, G CSA/FM Class III T Explosion Proof Enclosure with IS Probe: G CSA/FM Class I, Div. 1, Groups A, B, C, D CSA/FM Class II, Div. 1, Groups E, F, G CSA/FM Class III T General Purpose (CSA, FM) H General Purpose (CE, RCM) J General Purpose (CSA, FM, CE, RCM) K with WHG approval Enclosure and lid Aluminum epoxy coated 2 x ½" NPT via adapter - cable inlet, IP65 A 2 x M20 x1.5 cable inlet, IP65 B 2 x ½" NPT via adapter - cable inlet, IP68 C 2 x M20 x1.5 cable inlet, IP68 D 1) Sensor detached to allow customer to set desired cable length 2) Available with Approvals options F... H 7ML We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 9/5 in the appendix. Order code Further designs Please add "-Z" to and specify Order code(s). Total insertion length: enter the total insertion length Y01 in plain text description Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Y15 Measuring-point number/identification (max. 27 characters) specify in plain text Manufacturer's test certificate: M to DIN 55350, C11 Part 18 and ISO 9000 Inspection Certificate Type 3.1 per EN 1020 C12 SIL/IEC Declaration of Conformity C20 [SIL 2 (overspill)] Operating Instructions Note: The Operating Instructions should be See page /36 ordered as a separate line on the order. This device is shipped with the Siemens Milltronics manual DVD containing the ATEX Quick Start and manual library. Accessories See page /36 We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 9/5 in the appendix. Siemens FI 01 June 2015 /23

24 Point level measurement - RF Capacitance switches Pointek CLS200 - Standard Pointek CLS200 - Standard - Rod with Sanitary process connection 7ML Versatile inverse frequency shift capacitance level and material detection switch with optional rod/ cable choices and configurable output. CLS200 is ideal for detection of liquids, solids, slurries, foam, and interfaces, and has the ability to tune out buildup on the probe. Click on the for the online configuration in the PIA Life Cycle Portal. Process connection Sanitary 316L stainless steel 1" sanitary fitting clamp 8 A 1½" sanitary fitting clamp 8 B 2" sanitary fitting clamp 8 C 2½" sanitary fitting clamp 8 D 3" sanitary fitting clamp 8 E (Note: Sanitary connection dimensionally corresponds to the applicable ISO 2852 standard) Probe length (length from process connection face) Note: No Y01 needed in Order code for standard lengths Compact 98 mm (3.86 inch) A Extended rod, 250 mm (9.8 inch) B Extended rod, 350 mm (13.78 inch) C Extended rod, 500 mm (19.69 inch) D Extended rod, 750 mm (29.53 inch) E Extended rod, mm (39.37 inch) F Extended rod, mm (9.21 inch) G Extended rod, mm (53.15 inch) H Extended rod, mm (59.06 inch) J Extended rod, mm (68.90 inch) K Extended rod, mm (78.7 inch) L Add Order code Y01 and plain text: "Insertion length... mm" Extended rod, mm ( inch) M Extended rod, mm ( inch) N Extended rod, mm P ( inch) Extended rod, mm Q ( inch) Extended rod, mm R ( inch) Extended rod, mm S ( inch) Extended rod, mm T ( inch) Thermal isolator Without thermal isolator 0 With thermal isolator [for process connection 1 temperatures over 85 C (185 F)] Remote mount electronics and mounting bracket Remote mount electronics with 2 m (79 inch) 2 of cable 1) Remote mount electronics with 5 m (197 inch) 3 of cable 1) Wetted seals FKM 0 FFKM 1 [for process temperatures above -20 C (- F)] Probe material 316L stainless steel with PPS probe body 0 316L stainless steel with PVDF probe body 1 Pointek CLS200 - Standard - Rod with 7ML5632- Sanitary process connection Versatile inverse frequency shift capacitance level and material detection switch with optional rod/ cable choices and configurable output. CLS200 is ideal for detection of liquids, solids, slurries, foam, and interfaces, and has the ability to tune out buildup on the probe. Approvals Dust Ignition Proof: C CE, RCM, ATEX II 1/2 D T100 C Flameproof Enclosure with IS Probe: D CE, RCM, ATEX II 1 G EEx d[ia] IIC T6... T, ATEX II 1/2 D T100 C Flameproof Enclosure with IS Probe, E with WHG approval: CE, RCM, ATEX II 1/2 G EEx d[ia] IIC T6... T, ATEX II 1/2 D T100 C Dust Ignition Proof with IS Probe: F CSA/FM Class II, Div. 1, Groups E, F, G CSA/FM Class III T Explosion Proof Enclosure with IS Probe: G CSA/FM Class I, Div. 1, Groups A, B, C, D CSA/FM Class II, Div. 1, Groups E, F, G CSA/FM Class III T General Purpose (CSA, FM) H General Purpose (CE, RCM) J General Purpose (CSA, FM, CE, RCM) K with WHG approval Enclosure and lid Aluminum epoxy coated 2 x ½" NPT via adapter - cable inlet, IP65 A 2 x M20x1.5 cable inlet, IP65 B 2 x ½" NPT via adapter - cable inlet, IP68 C 2 x M20x1.5 cable inlet, IP68 D 1) Available with Approvals options F... H We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 9/5 in the appendix. Order code Further designs Please add "-Z" to and specify Order code(s). Total insertion length: enter the total insertion length Y01 in plain text description Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Y15 Measuring-point number/identification (max. 27 characters) specify in plain text Manufacturer's test certificate: M to DIN 55350, C11 Part 18 and ISO 9000 Inspection Certificate Type 3.1 per EN 1020 C12 SIL/IEC Declaration of Conformity C20 [SIL 2 (overspill)] Operating Instructions Note: The Operating Instructions should be See page /36 ordered as a separate line on the order. This device is shipped with the Siemens Milltronics manual DVD containing the ATEX Quick Start and manual library. Accessories See page /36 We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 9/5 in the appendix. /2 Siemens FI 01 June 2015

25 Point level measurement - RF Capacitance switches Pointek CLS200 - Standard Pointek CLS200 - Standard - Sliding Coupling with Threaded process connection Versatile inverse frequency shift capacitance level and material detection switch with optional rod/ cable choices and configurable output. CLS200 is ideal for detection of liquids, solids, slurries, foam, and interfaces, and has the ability to tune out buildup on the probe. Click on the for the online configuration in the PIA Life Cycle Portal. Process connection Threaded, 316L stainless steel ¾" NPT [(Taper), ANSI/ASME B1.20.1] 0 A 1" NPT [(Taper), ANSI/ASME B1.20.1] 0 B 1¼" NPT [(Taper), ANSI/ASME B1.20.1] 0 C 1½" NPT [(Taper), ANSI/ASME B1.20.1] 0 D R ¾" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] 1 A R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] 1 B R 1½" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] 1 D G ¾" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] 3 A G 1" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] 3 B G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] 3 D 7ML Probe length (length from flange face) (threaded lengths include process thread) Note: No Y01 needed in Order code for standard lengths Extended rod, 350 mm (13.78 inch) C Extended rod, 500 mm (19.69 inch) D Extended rod, 750 mm (29.53 inch) E Extended rod, mm (39.37 inch) F Extended rod, mm (9.21 inch) G Extended rod, mm (53.15 inch) H Extended rod, mm (59.06 inch) J Extended rod, mm (68.90 inch) K Extended rod, mm (78.7 inch) L Add Order code Y01 and plain text: "Insertion length... mm" Extended rod, mm M ( inch) Extended rod, mm N ( inch) Extended rod, mm ( inch) P Extended rod, mm ( inch) Q Extended rod, mm R ( inch) Extended rod, mm S ( inch) Thermal isolator Without thermal isolator 0 With thermal isolator [for process connection 1 temperatures over 85 C (185 F)] Remote mount electronics and mounting bracket With 2 m (79 inch) of cable 1) 2 With 5 m (197 inch) of cable 1) 3 Wetted seals FKM and PTFE 0 FFKM and PTFE [for process temperatures above 1-20 C (- F)] Probe material 316L stainless steel with PPS probe body 0 316L stainless steel with PVDF probe body 1 Pointek CLS200 - Standard - Sliding Coupling with Threaded process connection Versatile inverse frequency shift capacitance level and material detection switch with optional rod/ cable choices and configurable output. CLS200 is ideal for detection of liquids, solids, slurries, foam, and interfaces, and has the ability to tune out buildup on the probe. Approvals Dust Ignition Proof: C CE, RCM, ATEX II 1/2 D T100 C Flameproof Enclosure with IS Probe: D CE, RCM, ATEX II 1 G EEx d[ia] IIC T6...T, ATEX II 1/2 D T100 C Flameproof Enclosure with IS Probe, E with WHG approval: CE, RCM, ATEX II 1/2 G EEx d[ia] IIC T6...T, ATEX II 1/2 D T100 C Dust Ignition Proof with IS Probe: F CSA/FM Class II, Div. 1, Groups E, F, G CSA/FM Class III T Explosion Proof Enclosure with IS Probe: G CSA/FM Class I, Div. 1, Groups A, B, C, D CSA/FM Class II, Div. 1, Groups E, F, G CSA/FM Class III T General Purpose (CSA, FM) H General Purpose (CE, RCM) J General Purpose (CSA, FM, CE, RCM) K with WHG approval Enclosure and lid Aluminum epoxy coated 2 x ½" NPT via adapter - cable inlet, IP65 A 2 x M20x1.5 cable inlet, IP65 B 2 x ½" NPT via adapter - cable inlet, IP68 C 2 x M20x1.5 cable inlet, IP68 D 1) Available with Approvals options F... H 7ML We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 9/5 in the appendix. Order code Further designs Please add "-Z" to and specify Order code(s). Total insertion length: enter the total insertion length Y01 in plain text description Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Y15 Measuring-point number/identification (max. 27 characters) specify in plain text Manufacturer's test certificate: M to DIN 55350, C11 Part 18 and ISO 9000 Inspection Certificate Type 3.1 per EN 1020 C12 SIL/IEC Declaration of Conformity C20 [SIL 2 (overspill)] Operating Instructions Note: The Operating Instructions should be See page /36 ordered as a separate line on the order. This device is shipped with the Siemens Milltronics manual DVD containing the ATEX Quick Start and manual library. Accessories See page /36 We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 9/5 in the appendix. Siemens FI 01 June 2015 /25

26 Point level measurement - RF Capacitance switches Pointek CLS200 - Standard Pointek CLS200 - Standard - PFA Coated Rod with PFA Coated Flanged process connection Versatile inverse frequency shift capacitance level and material detection switch with optional rod/ cable choices and configurable output. CLS200 is ideal for detection of liquids, solids, slurries, foam, and interfaces, and has the ability to tune out buildup on the probe. Click on the for the online configuration in the PIA Life Cycle Portal. Process connection Welded flange, 316L stainless steel, raised face 1" ASME, 150 lb 5 A 1" ASME, 300 lb 5 B 1" ASME, 600 lb 5 C 1½" ASME, 150 lb 5 D 1½" ASME, 300 lb 5 E 1½" ASME, 600 lb 5 F 2" ASME, 150 lb 5 G 2" ASME, 300 lb 5 H 2" ASME, 600 lb 5 J 3" ASME, 150 lb 5 K 3" ASME, 300 lb 5 L 3" ASME, 600 lb 5 M " ASME, 150 lb 5 N " ASME, 300 lb 5 P " ASME, 600 lb 5 Q Welded flange, 316L stainless steel, Type A flat faced DN 25, PN 16 6 A DN 25, PN 0 6 B DN 0, PN 16 6 C DN 0, PN 0 6 D DN 50, PN 16 6 E DN 50, PN 0 6 F DN 80, PN 16 6 G DN 80, PN 0 6 H DN 100, PN 16 DN 100, PN 0 (Note: Flange bolting patterns and facings dimensionally correspond to the applicable ASME B16.5 or EN standard.) Probe length (length from flange face) (threaded lengths include process thread) Note: No Y01 needed in Order code for standard lengths Compact 98 mm (3.86 inch) Extended rod, 250 mm (9.8 inch) Extended rod, 350 mm (13.78 inch) Extended rod, 500 mm (19.69 inch) Extended rod, 750 mm (29.53 inch) Extended rod, mm (39.37 inch) Extended rod, mm (9.21 inch) Extended rod, mm (53.15 inch) Extended rod, mm (59.06 inch) Extended rod, mm (68.90 inch) Extended rod, mm (78.7 inch) Add Order code Y01 and plain text: "Insertion length... mm" Extended rod, mm ( inch) Extended rod, mm ( inch) Extended rod, mm ( inch) Extended rod, mm ( inch) Extended rod, mm ( inch) Extended rod, mm ( inch) 7ML J 6 K A B C D E F G H J K L M N P Q R S Pointek CLS200 - Standard - PFA Coated Rod 7ML563- with PFA Coated Flanged process connection Versatile inverse frequency shift capacitance level and material detection switch with optional rod/ cable choices and configurable output. CLS200 is ideal for detection of liquids, solids, slurries, foam, and interfaces, and has the ability to tune out buildup on the probe. Thermal isolator Without thermal isolator 0 With thermal isolator [for process connection 1 temperatures over 85 C (185 F)] Remote mount electronics and mounting bracket With 2 m (79 inch) of cable 2 With 5 m (197 inch) of cable 3 Wetted seals FKM 0 FFKM [for process temperatures above 1-20 C (- F)] Probe material PFA Coated 316L stainless steel with 0 PPS probe body PFA Coated 316L stainless steel with 1 PVDF probe body Approvals Dust Ignition Proof with IS Probe: F CSA/FM Class II, Div. 1, Groups E, F, G CSA/FM Class III T Explosion Proof Enclosure with IS Probe: G CSA/FM Class I, Div. 1, Groups A, B, C, D CSA/FM Class II, Div. 1, Groups E, F, G CSA/FM Class III T General Purpose (CSA, FM) H Enclosure and lid Aluminum epoxy coated 2 x ½" NPT via adapter - cable inlet, IP65 A 2 x M20x1.5 cable inlet, IP65 B 2 x ½" NPT via adapter - cable inlet, IP68 C 2 x M20x1.5 cable inlet, IP68 D Order code Further designs Please add "-Z" to and specify Order code(s). Total insertion length: enter the total insertion length Y01 in plain text description Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Y15 Measuring-point number/identification (max. 27 characters) specify in plain text Manufacturer's test certificate: M to DIN 55350, C11 Part 18 and ISO 9000 Inspection Certificate Type 3.1 per EN 1020 C12 SIL/IEC Declaration of Conformity C20 [SIL 2 (overspill)] Operating Instructions Note: The Operating Instructions should be See page /36 ordered as a separate line on the order. This device is shipped with the Siemens Milltronics manual DVD containing the ATEX Quick Start and manual library. Accessories See page /36 /26 Siemens FI 01 June 2015

27 Point level measurement - RF Capacitance switches Pointek CLS200 - Digital Overview Configuration Installation Pointek CLS200 (digital version) is a versatile inverse frequency shift capacitance level and material detection switch with optional rod/cable choices and configurable output. CLS200 is ideal for detection of liquids, solids, slurries, foam and interfaces and has the ability to tune out build-up on the probe. The digital version includes PROFIBUS PA, an LCD display, and advanced diagnostic features. Benefits Potted construction protects signal circuit from shock, vibration, humidity and/or condensation High chemical resistance Level detection independent of tank or pipe earth reference Insensitive to product buildup due to high frequency oscillation High sensitivity allows installation in a wide range of liquids, solids or slurry applications Integral LCD display allows for easy menu-driven setup PROFIBUS PA communication (SIMATIC PDM compatible) Keep unit out of path of falling material, or protect probe from falling material. Avoid areas where material build up occurs. Application Pointek CLS200 digital version provides an integral LCD display for stand-alone use, and also provides PROFIBUS PA communication (Profile version 3.0, Class B) for connection to a network. The power supply is galvanically isolated and accepts a wide range of voltages (12 to 30 V DC). When used with thermal isolator, the stainless steel and PPS (PVDF optional) materials used in the probe construction provide a temperature rating up to 125 C (257 F) on the process wetted portion of the probe. The switch responds to any material with a dielectric constant of 1.5 or more by detecting a change in oscillating frequency, and it can be set to detect before contact or on contact with the probe. The menu-driven setup allows precise control of the switch point signal damping and alarm functions. When connected to the PROFIBUS network, advanced diagnostics and set up using SIMATIC PDM are possible. The CLS200 operates independently of the tank wall or pipe so it does not require an external reference electrode for level detection in a non-conductive vessel such as concrete or plastic (EMC regulations applicable in some regions). Key Applications: liquids, slurries, powders, granules, pressurized applications, hazardous areas Install probe at least 50 (2) from tank wall. Pointek CLS200 installation, dimensions in mm (inch) Min. 50 (2) Siemens FI 01 June 2015 /27

28 Point level measurement - RF Capacitance switches Pointek CLS200 - Digital Technical specifications Mode of operation Measuring principle Inverse frequency shift capacitive level detection Input Measured variable Change in picofarad (pf) Output Output signal Solid-state output -Output Galvanically isolated -Protection Against reversed polarity (bipolar) - Max. switching voltage 30 V (DC) 30 V peak (AC) - Max. load current 82 ma - Voltage drop < 1 V, typical at 50 ma - Time delay (ON and/or OFF) Programmable by user ( s) Fail-safe mode Min. or max. Connection Removable terminal block Rated operating conditions 1) Installation conditions Location Indoor/outdoor Ambient conditions Ambient temperature C ( F) 2) Installation category II Pollution degree Medium conditions Liquids, bulk solids, slurries and interfaces Relative dielectric constant ε r Min. 1.5 Process temperature - Without thermal isolator C ( F) 2) - With thermal isolator C ( F) Process pressure (rod version) bar g ( psi g) (nominal) Process pressure (cable version) 3) bar g ( psi g) (nominal) Process pressure (sliding coupling bar g version) ( psi g) (nominal) Design Material Enclosure Epoxy-coated aluminum with gasket Optional thermal isolator 316L stainless steel Connection Removable terminal block, max. 2.5 mm² Degree of protection IP65/Type /NEMA (optional IP68) Cable inlet 2 x M20x1.5 thread (option: 2 x ½" NPT conduit entry including 1 plugged entry) Electromagnetic Compatibility To comply with CE EMC regulations (where applicable); the CLS200 should be installed per the instruction manual. Power supply Bus voltage Standard: V DC Intrinsically Safe: V DC Current consumption 12.5 ma Certificates and approvals General Purpose CSA, FM, CE, RCM Dust Ignition Proof ATEX II 1/2 D T100 C Dust Ignition Proof with IS Probe CSA/FM Class II, Div. 1, Groups E, F, G CSA/FM Class III T Flameproof Enclosure with IS Probe ATEX II 1/2 G EEx d[ia] IIC T6... T ATEX II 1/2 D T100 C Explosion Proof with IS Probe CSA/FM Class I, Div. 1, Groups A, B, C, D CSA/FM Class II, Div. 1, Groups E, F, G CSA/FM Class III T Intrinsically Safe ) ATEX II 1 G EEx ia IIC T6... T ATEX II 1/2 D IP6X T100 C CSA/FM Class I, Div. 1, Groups A, B, C, D CSA/FM Class II, Div. 1, Groups E, F, G CSA/FM Class III T Non-incendive CSA/FM Class I, Div. 2, Groups A, B, C, D CSA/FM Class II, Div. 2, Groups F, G CSA/FM Class III T or T6 Non-Sparking ATEX II 3 G Ex na II T6... T ATEX II 2 D IP6X T100 C Marine Lloyds Register of Shipping, Categories ENV1, ENV2 and ENV5 Others Pattern Approval (China) Communication PROFIBUS PA (IEC CPF3 CP3/2) Bus physical layer: IEC MBP (IS) Device profile: PROFIBUS PA profile for Process Control Devices Version 3.0, Class B FISCO field device 1) When operation is in areas classified as hazardous, observe restrictions according to relevant certificate. See also Pressure/Temperature curves on page /37. 2) Thermal isolator is used if process connection temperature exceeds 85 C (185 F) 3) Pressure rating of process seal is temperature dependent. See Pressure/ Temperature curves on page /37. ) Barrier or Intrinsically Safe power supply required for Intrinsically Safe protection /28 Siemens FI 01 June 2015

29 Point level measurement - RF Capacitance switches Pointek CLS200 - Digital Design: Probe Rod version Sanitary version Cable version Sliding Coupling version Max. length mm ( inch) mm ( inch) mm ( inch) mm ( inch) liquids and slurries mm ( inch) solids (under loads) Process connection R ¾", 1", 1¼", 1½" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] ¾", 1", 1¼", 1½" NPT [(Taper), ANSI/ASME B1.20.1] G ¾", 1", 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] 1½", 2" sanitary fitting clamp 316L stainless steel R ¾", 1", 1¼", 1½" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] ¾", 1", 1¼", 1½" NPT [(Taper), ANSI/ASME B1.20.1] G ¾", 1", 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] R ¾", 1", 1¼", 1½ inch [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] ¾", 1", 1¼", 1½" NPT [(Taper), ANSI/ASME B1.20.1] G ¾", 1", 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] 316L stainless steel ASME/EN flange 316L stainless steel ASME/EN flange Extension material 316L stainless steel 316L stainless steel Fluoroethylene propylene 316L stainless steel optional PFA coated 1) (FEP) cable with stainless steel core Sensor wetted parts PPS (optional PVDF) PPS (optional PVDF) PPS (optional PVDF) PPS (optional PVDF) O-ring seal material FKM (optional FFKM) 2) FKM (optional FFKM) 2) FKM (optional FFKM) 2) FKM (optional FFKM) 2) Thermal isolator 3) Optional Optional Optional Optional Extension User selected length User selected length Cable extension User selected length 1) PFA coating (7ML563 and 7ML56) has 120 micron thickness 2) For Caustic Materials, please contact ceg.smpi@siemens.com for alternative O-rings 3) Thermal isolator is used if process connection temperature exceeds 85 C (185 F). Siemens FI 01 June 2015 /29

30 Point level measurement - RF Capacitance switches Pointek CLS200 - Digital Pointek CLS200 - Digital - Rod with Threaded or Flanged process connection 7ML Versatile inverse frequency shift capacitance level and material detection switch with optional process connection choices and configurable output. CLS200 is ideal for detection of liquids, solids, slurries, foam, and interfaces, and has the ability to tune out build-up on the probe. Click on the for the online configuration in the PIA Life Cycle Portal. Process connection Threaded, 316L stainless steel ¾" NPT [(Taper), ANSI/ASME B1.20.1] 0 A 1" NPT [(Taper), ANSI/ASME B1.20.1] 0 B 1¼" NPT [(Taper), ANSI/ASME B1.20.1] 0 C 1½" NPT [(Taper), ANSI/ASME B1.20.1] 0 D R ¾" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] 1 A R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] 1 B R 1½" [(BSPT), EN 10226/PT (JIS-T), 1 D JIS B 0203] G ¾" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] 3 A G 1" [(BSPP), EN ISO 228-1/PF (JIS-P), 3 B JIS B 0202] G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), 3 D JIS B 0202] Welded flange, 316L stainless steel, raised face 1" ASME, 150 lb 5 A 1" ASME, 300 lb 5 B 1" ASME, 600 lb 5 C 1½" ASME, 150 lb 5 D 1½" ASME, 300 lb 5 E 1½" ASME, 600 lb 5 F 2" ASME, 150 lb 5 G 2" ASME, 300 lb 5 H 2" ASME, 600 lb 5 J 3" ASME, 150 lb 5 K 3" ASME, 300 lb 5 L 3" ASME, 600 lb 5 M " ASME, 150 lb 5 N " ASME, 300 lb 5 P " ASME, 600 lb 5 Q Welded flange, 316L stainless steel, Type A flat faced DN 25, PN 16 6 A DN 25, PN 0 6 B DN 0, PN 16 6 C DN 0, PN 0 6 D DN 50, PN 16 6 E DN 50, PN 0 6 F DN 80, PN 16 6 G DN 80, PN 0 6 H DN 100, PN 16 6 J DN 100, PN 0 6 K (Note: Flange bolting patterns and facings dimensionally correspond to the applicable ASME B16.5 or EN standard.) Probe length (length from flange face) (threaded lengths include process thread) Note: No Y01 needed in Order code for standard lengths Compact [threaded 120 mm (.72 inch), A Flanged 98 mm (3.86 inch)] Extended rod, 250 mm (9.8 inch) B Extended rod, 350 mm (13.78 inch) C Extended rod, 500 mm (19.69 inch) D Extended rod, 750 mm (29.53 inch) E Extended rod, mm (39.37 inch) F Extended rod, mm (9.21 inch) G Extended rod, mm (53.15 inch) H Extended rod, mm (59.06 inch) J Extended rod, mm (68.90 inch) K Extended rod, mm (78.7 inch) L Pointek CLS200 - Digital - Rod with Threaded or Flanged process connection 7ML Versatile inverse frequency shift capacitance level and material detection switch with optional process connection choices and configurable output. CLS200 is ideal for detection of liquids, solids, slurries, foam, and interfaces, and has the ability to tune out build-up on the probe. Add Order code Y01 and plain text: "Insertion length... mm" Extended rod, mm M ( inch) Extended rod, mm N ( inch) Extended rod, mm P ( inch) Extended rod, mm Q ( inch) Extended rod, mm R ( inch) Extended rod, mm S ( inch) Thermal isolator Without thermal isolator 0 With thermal isolator [for process connection 1 temperatures over 85 C (185 F)] Remote mount electronics and mounting bracket With 2 m (79 inch) of cable 2 With 5 m (197 inch) of cable 3 Wetted seals FKM 0 FFKM [for process temperatures above 1-20 C (- F)] Probe material 316L stainless steel with PPS probe body 0 316L stainless steel with PVDF probe body 1 Approvals Non-Sparking: B CE, RCM, ATEX II 3 G Ex na II T6...T, ATEX II 2 D IP6X T100 C Dust Ignition Proof: C CE, RCM, ATEX II 1/2 D T100 C Intrinsically Safe: 1) D CE, RCM, ATEX II 1 G EEx ia IIC T6...T, ATEX II 1/2 D IP6X T100 C Flameproof Enclosure with IS Probe: E CE, RCM, ATEX II 1/2 G EEx d[ia] IIC T6...T, ATEX II 1/2 D T100 C Non-incendive: F CSA/FM Class I, Div. 2, Groups A, B, C, D CSA/FM Class II, Div. 2, Groups F, G CSA/FM Class III T or T6 Dust Ignition Proof with IS Probe: G CSA/FM Class II, Div. 1, Groups E, F, G CSA/FM Class III T Intrinsically Safe: 1) H CSA/FM Class I, Div. 1, Groups A, B, C, D CSA/FM Class II, Div. 1, Groups E, F, G CSA/FM Class III T Explosion Proof with IS Probe: J CSA/FM Class I, Div. 1, Groups A, B, C, D CSA/FM Class II, Div. 1, Groups E, F, G CSA/FM Class III T General Purpose (CSA, FM) K General Purpose (CE, RCM) L /30 Siemens FI 01 June 2015

31 Point level measurement - RF Capacitance switches Pointek CLS200 - Digital We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 9/5 in the appendix. Order code Further designs Please add "-Z" to and specify Order code(s). Total insertion length: enter the total insertion length Y01 in plain text description Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Y15 Measuring-point number/identification (max. 27 characters) specify in plain text Manufacturer's test certificate: M to DIN 55350, C11 Part 18 and ISO 9000 Inspection Certificate Type 3.1 per EN 1020 C12 Operating Instructions Note: The Operating Instructions should be See page /36 ordered as a separate line on the order. This device is shipped with the Siemens Milltronics manual DVD containing the ATEX Quick Start and manual library. Accessories See page /36 We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 9/5 in the appendix. Pointek CLS200 - Digital - Cable with Threaded or Flanged process connection Versatile inverse frequency shift capacitance level and material detection switch with optional process connection choices and configurable output. CLS200 is ideal for detection of liquids, solids, slurries, foam, and interfaces, and has the ability to tune out build-up on the probe. Click on the for the online configuration in the PIA Life Cycle Portal. Process connection Threaded, 316L stainless steel ¾" NPT [(Taper), ANSI/ASME B1.20.1] 0 A 1" NPT [(Taper), ANSI/ASME B1.20.1] 0 B 1¼" NPT [(Taper), ANSI/ASME B1.20.1] 0 C 1½" NPT [(Taper), ANSI/ASME B1.20.1] 0 D R ¾" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] 1 A R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] R 1½" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] Pointek CLS200 - Digital - Rod 7ML560- with Threaded or Flanged process connection Versatile inverse frequency shift capacitance level and material detection switch with optional process connection choices and configurable output. CLS200 is ideal for detection of liquids, solids, slurries, foam, and interfaces, and has the ability to tune out build-up on the probe. Enclosure and lid Aluminum epoxy coated 2 x ½" NPT via adapter - cable inlet, IP65 A 2 x M20x1.5 cable inlet, IP65 B 2 x ½" NPT via adapter - cable inlet, IP68 C 2 x M20x1.5 cable inlet, IP68 D 1) Barrier or Intrinsically Safe power supply required for Intrinsically Safe protection 7ML B 1 D G ¾" [(BSPP), EN ISO 228-1/PF (JIS-P), 3 A JIS B 0202] G 1" [(BSPP), EN ISO 228-1/PF (JIS-P), 3 B JIS B 0202] G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), 3 D JIS B 0202] Welded flange, 316L stainless steel, raised face 1" ASME, 150 lb 5 A 1" ASME, 300 lb 5 B 1" ASME, 600 lb 5 C 1½" ASME, 150 lb 5 D 1½" ASME, 300 lb 5 E 1½" ASME, 600 lb 5 F 2" ASME, 150 lb 5 G 2" ASME, 300 lb 5 H 2" ASME, 600 lb 5 J 3" ASME, 150 lb 5 K 3" ASME, 300 lb 5 L 3" ASME, 600 lb 5 M " ASME, 150 lb 5 N " ASME, 300 lb 5 P " ASME, 600 lb 5 Q Welded flange, 316L stainless steel, Type A flat faced DN 25, PN 16 6 A DN 25, PN 0 6 B DN 0, PN 16 6 C DN 0, PN 0 6 D DN 50, PN 16 6 E DN 50, PN 0 6 F DN 80, PN 16 6 G DN 80, PN 0 6 H DN 100, PN 16 6 J DN 100, PN 0 6 K (Note: Flange bolting patterns and facings dimensionally correspond to the applicable ASME B16.5 or EN standard.) Siemens FI 01 June 2015 /31

32 Point level measurement - RF Capacitance switches Pointek CLS200 - Digital Pointek CLS200 - Digital - Cable with Threaded or Flanged process connection Versatile inverse frequency shift capacitance level and material detection switch with optional process connection choices and configurable output. CLS200 is ideal for detection of liquids, solids, slurries, foam, and interfaces, and has the ability to tune out build-up on the probe. Probe length (length from flange face) (threaded lengths include process thread) Note: No Y01 needed in Order code for standard lengths Extended cable, mm ( inch), length can be determined by customer on assembly Extended cable, mm ( inch), length can be determined by customer on assembly Add Order code Y01 and plain text: "Insertion length... mm" Extended cable, mm ( inch) Extended cable, mm ( inch) Extended cable, mm ( inch) Extended cable, mm ( inch) Extended cable, mm ( inch) Extended cable, mm ( inch) Thermal isolator Without thermal isolator 0 With thermal isolator [for process connection 1 temperatures over 85 C (185 F)] Remote mount electronics and mounting bracket With 2 m (79 inch) of cable 2 With 5 m (197 inch) of cable 3 Wetted seals FKM and PTFE 0 FFKM and PTFE [for process temperatures 1 above -20 C (- F)] Probe material FEP jacketed cable with PPS probe body 0 FEP jacketed cable with PVDF probe body 1 Approvals Non-Sparking: CE, RCM, ATEX II 3 G Ex na II T6...T, B ATEX II 2 D IP6X T100 C Dust Ignition Proof: C CE, RCM, ATEX II 1/2 D T100 C Intrinsically Safe: 1) D CE, RCM, ATEX II 1 G EEx ia IIC T6...T, ATEX II 1/2 D IP6X T100 C Flameproof Enclosure with IS Probe: E CE, RCM, ATEX II 1/2 G EEx d[ia] IIC T6...T, ATEX II 1/2 D T100 C Non-incendive: F CSA/FM Class I, Div. 2, Groups A, B, C, D CSA/FM Class II, Div. 2, Groups F, G CSA/FM Class III T or T6 Dust Ignition Proof with IS Probe: G CSA/FM Class II, Div. 1, Groups E, F, G CSA/FM Class III T Intrinsically Safe: 1) H CSA/FM Class I, Div. 1, Groups A, B, C, D CSA/FM Class II, Div. 1, Groups E, F, G CSA/FM Class III T Explosion Proof with IS Probe: J CSA/FM Class I, Div. 1, Groups A, B, C, D CSA/FM Class II, Div. 1, Groups E, F, G CSA/FM Class III T General Purpose (CSA, FM) K General Purpose (CE, RCM) L 7ML A B C D E F G H Pointek CLS200 - Digital - Cable with Threaded or Flanged process connection Versatile inverse frequency shift capacitance level and material detection switch with optional process connection choices and configurable output. CLS200 is ideal for detection of liquids, solids, slurries, foam, and interfaces, and has the ability to tune out build-up on the probe. 7ML Enclosure and lid Aluminum epoxy coated 2 x ½" NPT via adapter - cable inlet, IP65 A 2 x M20x1.5 cable inlet, IP65 B 2 x ½" NPT via adapter - cable inlet, IP68 C 2 x M20x1.5 cable inlet, IP68 D 1) Barrier or Intrinsically Safe power supply required for Intrinsically Safe protection We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 9/5 in the appendix. Order code Further designs Please add "-Z" to and specify Order code(s). Total insertion length: enter the total insertion length Y01 in plain text description Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Y15 Measuring-point number/identification (max. 27 characters) specify in plain text Manufacturer's test certificate: M to DIN 55350, C11 Part 18 and ISO 9000 Inspection Certificate Type 3.1 per EN 1020 C12 Operating Instructions Note: The Operating Instructions should be See page /36 ordered as a separate line on the order. This device is shipped with the Siemens Milltronics manual DVD containing the ATEX Quick Start and manual library. Accessories See page /36 We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 9/5 in the appendix. /32 Siemens FI 01 June 2015

33 Point level measurement - RF Capacitance switches Pointek CLS200 - Digital Pointek CLS200 - Digital - Rod with Sanitary process connection Versatile inverse frequency shift capacitance level 7ML and material detection switch with optional process connection choices and configurable output. CLS200 is ideal for detection of liquids, solids, slurries, foam, and interfaces, and has the ability to tune out build-up on the probe. Click on the for the online configuration in the PIA Life Cycle Portal. Process connection Sanitary 316L stainless steel 1" sanitary fitting clamp 8 A 1½" sanitary fitting clamp 8 B 2" sanitary fitting clamp 8 C 2½" sanitary fitting clamp 8 D 3" sanitary fitting clamp 8 E (Note: Sanitary connection dimensionally corresponds to the applicable ISO 2852 standard.) Probe length (length from process connection face) Note: No Y01 needed in Order code for standard lengths Compact, 98 mm (3.86 inch) A Extended rod, 250 mm (9.8 inch) B Extended rod, 350 mm (13.78 inch) C Extended rod, 500 mm (19.69 inch) D Extended rod, 750 mm (29.53 inch) E Extended rod, mm (39.37 inch) F Extended rod, mm (9.21 inch) G Extended rod, mm (53.15 inch) H Extended rod, mm (59.06 inch) J Extended rod, mm (68.90 inch) K Extended rod, mm (78.7 inch) L Add Order code Y01 and plain text: "Insertion length... mm" Extended rod, mm M ( inch) Extended rod, mm N ( inch) Extended rod, mm P ( inch) Extended rod, mm Q ( inch) Extended rod, mm R ( inch) Extended rod, mm S ( inch) Extended rod, mm T ( inch) Thermal isolator Without thermal isolator 0 With thermal isolator [for process connection 1 temperatures over 85 C (185 F)] Remote mount electronics and mounting bracket With 2 m (79 inch) of cable 2 With 5 m (197 inch) of cable 3 Wetted seals FKM 0 FFKM [for process temperatures above -20 C (- F)] 1 Probe material 316L stainless steel with PPS probe body 0 316L stainless steel with PVDF probe body 1 Approvals Non-Sparking: CE, RCM, ATEX II 3 G Ex na II T6...T, ATEX II 2 D IP6X T100 C Dust Ignition Proof: CE, RCM, ATEX II 1/2 D T100 C Intrinsically Safe: 1) CE, RCM, ATEX II 1 G EEx ia IIC T6...T, ATEX II 1/2 D IP6X T100 C Flameproof Enclosure with IS Probe: CE, RCM, ATEX II 1/2 G EEx d[ia] IIC T6...T, ATEX II 1/2 D T100 C B C D E Pointek CLS200 - Digital - Rod with Sanitary process connection Versatile inverse frequency shift capacitance level and material detection switch with optional process connection choices and configurable output. CLS200 is ideal for detection of liquids, solids, slurries, foam, and interfaces, and has the ability to tune out build-up on the probe. 7ML Non-incendive: F CSA/FM Class I, Div. 2, Groups A, B, C, D CSA/FM Class II, Div. 2, Groups F, G CSA/FM Class III T or T6 Dust Ignition Proof with IS Probe: G CSA/FM Class II, Div. 1, Groups E, F, G CSA/FM Class III T Intrinsically Safe: 1) H CSA/FM Class I, Div. 1, Groups A, B, C, D CSA/FM Class II, Div. 1, Groups E, F, G CSA/FM Class III T Explosion Proof with IS Probe: J CSA/FM Class I, Div. 1, Groups A, B, C, D CSA/FM Class II, Div. 1, Groups E, F, G CSA/FM Class III T General Purpose (CSA, FM) K General Purpose (CE, RCM) L Enclosure and lid Aluminum epoxy coated 2 x ½" NPT via adapter - cable inlet, IP65 A 2 x M20x1.5 cable inlet, IP65 B 2 x ½" NPT via adapter - cable inlet, IP68 C 2 x M20x1.5 cable inlet, IP68 D 1) Barrier or Intrinsically Safe power supply required for Intrinsically Safe protection We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 9/5 in the appendix. Order code Further designs Please add "-Z" to and specify Order code(s). Total insertion length: enter the total insertion length Y01 in plain text description Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Y15 Measuring-point number/identification (max. 27 characters) specify in plain text Manufacturer's test certificate: M to DIN 55350, C11 Part 18 and ISO 9000 Inspection Certificate Type 3.1 per EN 1020 C12 Operating Instructions Note: The Operating Instructions should be See page /36 ordered as a separate line on the order. This device is shipped with the Siemens Milltronics manual DVD containing the ATEX Quick Start and manual library. Accessories See page /36 We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 9/5 in the appendix. Siemens FI 01 June 2015 /33

34 Point level measurement - RF Capacitance switches Pointek CLS200 - Digital Pointek CLS200 - Digital - Rod with Sliding coupling with Threaded process connection Versatile inverse frequency shift capacitance level and material detection switch with optional process connection choices and configurable output. CLS200 is ideal for detection of liquids, solids, slurries, foam, and interfaces, and has the ability to tune out build-up on the probe. 7ML Click on the for the online configuration in the PIA Life Cycle Portal. Process connection Threaded, 316L stainless steel ¾" NPT [(Taper), ANSI/ASME B1.20.1] 0 A 1" NPT [(Taper), ANSI/ASME B1.20.1] 0 B 1¼" NPT [(Taper), ANSI/ASME B1.20.1] 0 C 1½" NPT [(Taper), ANSI/ASME B1.20.1] 0 D R ¾" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] 1 A R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] 1 B R 1½" [(BSPT), EN 10226/PT (JIS-T), 1 D JIS B 0203] G ¾" [(BSPP), EN ISO 228-1/PF (JIS-P), 3 A JIS B 0202] G 1" [(BSPP), EN ISO 228-1/PF (JIS-P), 3 B JIS B 0202] G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), 3 D JIS B 0202] Probe length (length from flange face) (threaded lengths include process thread) Note: No Y01 needed in Order code for standard lengths Extended rod, 350 mm (13.78 inch) C Extended rod, 500 mm (19.69 inch) D Extended rod, 750 mm (29.53 inch) E Extended rod, mm (39.37 inch) F Extended rod, mm (9.21 inch) G Extended rod, mm (53.15 inch) H Extended rod, mm (59.06 inch) J Extended rod, mm (68.90 inch) K Extended rod, mm (78.7 inch) L Add Order code Y01 and plain text: "Insertion length... mm" Extended rod, mm M ( inch) Extended rod, mm N ( inch) Extended rod, mm P ( inch) Extended rod, mm Q ( inch) Extended rod, mm R ( inch) Extended rod, mm S ( inch) Thermal isolator Without thermal isolator 0 With thermal isolator [for process connection 1 temperatures over 85 C (185 F)] Remote mount electronics and mounting bracket With 2 m (79 inch) of cable 2 With 5 m (197 inch) of cable 3 Wetted seals FKM and PTFE 0 FFKM and PTFE [for process temperatures above 1-20 C (- F)] Probe material 316L stainless steel with PPS probe body 0 316L stainless steel with PVDF probe body 1 Approvals Non-Sparking: B CE, RCM, ATEX II 3 G Ex na II T6...T, ATEX II 2 D IP6X T100 C Dust Ignition Proof: C CE, RCM, ATEX II 1/2 D T100 C Intrinsically Safe: 1) CE, RCM, ATEX II 1 G EEx ia IIC T6...T, ATEX II 1/2 D IP6X T100 C D Pointek CLS200 - Digital - Rod with Sliding coupling with Threaded process connection Versatile inverse frequency shift capacitance level and material detection switch with optional process connection choices and configurable output. CLS200 is ideal for detection of liquids, solids, slurries, foam, and interfaces, and has the ability to tune out build-up on the probe. 7ML Flameproof Enclosure with IS Probe: E CE, RCM, ATEX II 1/2 G EEx d[ia] IIC T6...T, ATEX II 1/2 D T100 C Non-incendive: F CSA/FM Class I, Div. 2, Groups A, B, C, D CSA/FM Class II, Div. 2, Groups F, G CSA/FM Class III T or T6 Dust Ignition Proof with IS Probe: G CSA/FM Class II, Div. 1, Groups E, F, G CSA/FM Class III T Intrinsically Safe: 1) H CSA/FM Class I, Div. 1, Groups A, B, C, D CSA/FM Class II, Div. 1, Groups E, F, G CSA/FM Class III T Explosion Proof with IS Probe: J CSA/FM Class I, Div. 1, Groups A, B, C, D CSA/FM Class II, Div. 1, Groups E, F, G CSA/FM Class III T General Purpose (CSA, FM) K General Purpose (CE, RCM) L Enclosure and lid Aluminum epoxy coated 2 x ½" NPT via adapter - cable inlet, IP65 A 2 x M20x1.5 cable inlet, IP65 B 2 x ½" NPT via adapter - cable inlet, IP68 C 2 x M20x1.5 cable inlet, IP68 D 1) Barrier or Intrinsically Safe power supply required for Intrinsically Safe protection We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 9/5 in the appendix. Order code Further designs Please add "-Z" to and specify Order code(s). Total insertion length: enter the total insertion length Y01 in plain text description Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Y15 Measuring-point number/identification (max. 27 characters) specify in plain text Manufacturer's test certificate: M to DIN 55350, C11 Part 18 and ISO 9000 Inspection Certificate Type 3.1 per EN 1020 C12 Operating Instructions Note: The Operating Instructions should be See page /36 ordered as a separate line on the order. This device is shipped with the Siemens Milltronics manual DVD containing the ATEX Quick Start and manual library. Accessories See page /36 We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 9/5 in the appendix. /3 Siemens FI 01 June 2015

35 Point level measurement - RF Capacitance switches Pointek CLS200 - Digital Pointek CLS200 - Digital - PFA Rod with PFA Flanged process connection Versatile inverse frequency shift capacitance level and material detection switch with optional process connection choices and configurable output. CLS200 is ideal for detection of liquids, solids, slurries, foam, and interfaces, and has the ability to tune out build-up on the probe. Click on the for the online configuration in the PIA Life Cycle Portal. Process connection Welded flange, PFA coated, 316L stainless steel, raised face 1" ASME, 150 lb 5 A 1" ASME, 300 lb 5 B 1" ASME, 600 lb 5 C 1½" ASME, 150 lb 5 D 1½" ASME, 300 lb 5 E 1½" ASME, 600 lb 5 F 2" ASME, 150 lb 5 G 2" ASME, 300 lb 5 H 2" ASME, 600 lb 5 J 3" ASME, 150 lb 5 K 3" ASME, 300 lb 5 L 3" ASME, 600 lb 5 M " ASME, 150 lb 5 N " ASME, 300 lb 5 P " ASME, 600 lb 5 Q Welded flange, PFA coated, 316L stainless steel, Type A flat faced DN 25, PN 16 6 A DN 25, PN 0 6 B DN 0, PN 16 6 C DN 0, PN 0 6 D DN 50, PN 16 6 E DN 50, PN 0 6 F DN 80, PN 16 6 G DN 80, PN 0 6 H DN 100, PN 16 DN 100, PN 0 (Note: Flange bolting patterns and facings dimensionally correspond to the applicable ASME B16.5 or EN standard.) Probe length (length from process connection face) Note: No Y01 needed in Order code for standard lengths Compact, 98 mm (3.86 inch) Extended rod, 250 mm (9.8 inch) Extended rod, 350 mm (13.78 inch) Extended rod, 500 mm (19.69 inch) Extended rod, 750 mm (29.53 inch) Extended rod, mm (39.37 inch) Extended rod, mm (9.21 inch) Extended rod, mm (53.15 inch) Extended rod, mm (59.06 inch) Extended rod, mm (68.90 inch) Extended rod, mm (78.7 inch) Add Order code Y01 and plain text: "Insertion length... mm" Extended rod, mm ( inch) Extended rod, mm ( inch) Extended rod, mm ( inch) Extended rod, mm ( inch) Extended rod, mm ( inch) Extended rod, mm ( inch) Thermal isolator 7ML J 6 K Without thermal isolator 0 With thermal isolator [for process connection 1 temperatures over 85 C (185 F)] A B C D E F G H J K L M N P Q R S Pointek CLS200 - Digital - PFA Rod with PFA Flanged process connection Versatile inverse frequency shift capacitance level and material detection switch with optional process connection choices and configurable output. CLS200 is ideal for detection of liquids, solids, slurries, foam, and interfaces, and has the ability to tune out build-up on the probe. 7ML Remote mount electronics and mounting bracket With 2 m (79 inch) of cable 2 With 5 m (197 inch) of cable 3 Wetted seals FKM 0 FFKM [for process temperatures above 1-20 C (- F)] Probe material PFA Coated 316L stainless steel with PPS probe 0 body PFA Coated 316L stainless steel with PVDF probe 1 body Approvals Non-incendive: F CSA/FM Class I, Div. 2, Groups A, B, C, D CSA/FM Class II, Div. 2, Groups F, G CSA/FM Class III T or T6 Dust Ignition Proof with IS Probe: G CSA/FM Class II, Div. 1, Groups E, F, G CSA/FM Class III T Intrinsically Safe: 1) H CSA/FM Class I, Div. 1, Groups A, B, C, D CSA/FM Class II, Div. 1, Groups E, F, G CSA/FM Class III T Explosion Proof with IS Probe: J CSA/FM Class I, Div. 1, Groups A, B, C, D CSA/FM Class II, Div. 1, Groups E, F, G CSA/FM Class III T General Purpose (CSA, FM) K Enclosure and lid Aluminum epoxy coated 2 x ½" NPT via adapter - cable inlet, IP65 A 2 x M20x1.5 cable inlet, IP65 B 2 x ½" NPT via adapter - cable inlet, IP68 C 2 x M20x1.5 cable inlet, IP68 D 1) Barrier or Intrinsically Safe power supply required for Intrinsically Safe protection Order code Further designs Please add "-Z" to and specify Order code(s). Total insertion length: enter the total insertion length Y01 in plain text description Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Y15 Measuring-point number/identification (max. 27 characters) specify in plain text Manufacturer's test certificate: M to DIN 55350, C11 Part 18 and ISO 9000 Inspection Certificate Type 3.1 per EN 1020 C12 Operating Instructions Note: The Operating Instructions should be See page /36 ordered as a separate line on the order. This device is shipped with the Siemens Milltronics manual DVD containing the ATEX Quick Start and manual library. Accessories See page /36 Siemens FI 01 June 2015 /35

36 Point level measurement - RF Capacitance switches Pointek CLS200 Standard and Digital Operating Instructions - Standard Options English German 7ML1998-5JH0 7ML1998-5JH3 Optional SensGuard Internal thread ¾" NPT Functional Safety manual, English Note: The Operating Instructions should be ordered as a separate line on the order. Quick Start manual, multi-language This device is shipped with the Siemens Milltronics manual DVD containing the ATEX Quick Start and Operating Instructions library. Operating Instructions - Digital English A5E A5E ML1998-5JJ05 32 (1.26) 91 (3.6) Process connection ¾" NPT 70 (2.75) 32 (1.26) 91 (3.6) Process connection R 1" (BSPT) 70 (2.75) German French Note: The Operating Instructions should be ordered as a separate line on the order. 7ML1998-5JJ3 7ML1998-5JJ11 Optional SensGuard, dimensions in mm (inch) Quick Start manual, multi-language A5E This device is shipped with the Siemens Milltronics manual DVD containing the ATEX Quick Start and Operating Instructions library. Accessories SensGuard, ¾" NPT (PPS) Only available for CLS200 with ¾" NPT thread 7ML1830-1DL SensGuard, R 1" (BSPT) (PPS) Only available for CLS200 with ¾" NPT thread 7ML1830-1DM One metallic cable gland M20x1.5, C ( F) with integrated shield connection (available for PROFIBUS PA) 7ML1930-1AQ General Purpose 1/2" NPT General Purpose Cable Entry IP68/IP69K NEMA6, C ( F), cable size mm ( inch) 7ML1830-1JA M20x1.5 General Purpose Cable Entry IP68/IP69K NEMA6, C ( F), cable size mm ( inch) 7ML1830-1JC Hazardous Locations 1/2" NPT EMC rated Cable Gland: Dust Ignition Proof, Flameproof Exd, and Increased Safety ATEX II 2 GD ExtD A21 (Zone 1, Zone 2, Zone 21, Zone 22, and in Gas Groups IIA,IIB and IIC) C IP66, IP67, IP68, NEMAX, cable sizes mm ( inch) 7ML1830-1JB M20 EMC rated Cable Gland: Dust Ignition Proof, Flameproof Exd, and Increased Safety ATEX II 2 GD ExtD A21 (Zone 1, Zone 2, Zone 21, Zone 22 and in Gas Groups IIA, IIB and IIC) C IP66, IP67, IP68, NEMAX, cable sizes mm ( inch) 7ML1830-1JD Blind threaded flanges are available. Please contact ceg.smpi@siemens.com with a completed application data sheet on page /11 Pointek Specials See page /80 /36 Siemens FI 01 June 2015

37 Point level measurement - RF Capacitance switches Pointek CLS200 Standard and Digital Characteristic curves Pressure/temperature curve CLS200 sliding coupling threaded process connections (7ML5633 and 7ML563) Permitted operating pressures P 30 bar (35 psi) 20 bar (290 psi) Atmospheric -1 bar (-1.5 psi) -150 ºC (-238 ºF) -100 ºC (-18 ºF) 10 bar (15 psi) -0 ºF 1 ºF (-0 ºC) (-10 ºC) -50 ºC (-58 ºF) -29 ºC (-20 ºF) 100 ºF (38 ºC) 200 ºF (93 ºC) 0 ºC RT 50 ºC 100 ºC (32 ºF) (122 ºF) (212 ºF) 300 ºF (19 ºC) 150 ºC (302 ºF) 00 ºF (20 ºC) 200 ºC (392 ºF) Permitted operating temperature T Example: Permitted operating pressure = 10 bar (15 psi) at 75 C Pointek CLS200 Process Pressure/Temperature derating curves (7ML5633 and 7ML563) Pressure/temperature curve CLS200 cable Threaded process connections (7ML5631 and 7ML561) Permitted operating pressures P 30 bar (35 psi) 20 bar (290 psi) Atmospheric -1 bar (-1.5 psi) -150 ºC (-238 ºF) -100 ºC (-18 ºF) 10 bar (15 psi) -0 ºF 1 ºF (-0 ºC) (-10 ºC) -50 ºC (-58 ºF) -29 ºC (-20 ºF) 100 ºF (38 ºC) 200 ºF (93 ºC) 0 ºC RT 50 ºC 100 ºC (32 ºF) (122 ºF) (212 ºF) 300 ºF (19 ºC) 150 ºC (302 ºF) 00 ºF (20 ºC) 200 ºC (392 ºF) Permitted operating temperature T Pointek CLS200 Process Pressure/Temperature derating curves (7ML5631 and 7ML561) Siemens FI 01 June 2015 /37

38 Point level measurement - RF Capacitance switches Pointek CLS200 Standard and Digital Pressure/temperature curve CLS200 compact and extended rod Threaded process connections (7ML5630 and 7ML560) Permitted operating pressures P 0 bar (580 psi) 30 bar (35 psi) 20 bar (290 psi) Atmospheric -1 bar (-1.5 psi) -150 ºC (-238 ºF) -100 ºC (-18 ºF) 10 bar (15 psi) -0 ºF 1 ºF (-0 ºC) (-10 ºC) -50 ºC (-58 ºF) 100 ºF (38 ºC) 200 ºF (93 ºC) 0 ºC RT 50 ºC 100 ºC (32 ºF) (122 ºF) (212 ºF) 300 ºF (19 ºC) 150 ºC (302 ºF) 00 ºF (20 ºC) 200 ºC (392 ºF) -29 ºC (-20 ºF) Permitted operating temperature T Pointek CLS200 Process Pressure/Temperature derating curves (7ML5630 or 7ML560) Pressure/temperature curve CLS200 compact and extended sanitary type Sanitary process connections (7ML5632 and 7ML562) Permitted operating pressures P 30 bar (35 psi) 20 bar (290 psi) Atmospheric -1 bar (-1.5 psi) -150 ºC (-238 ºF) -100 ºC (-18 ºF) 10 bar (15 psi) -0 ºF 1 ºF (-0 ºC) (-10 ºC) -50 ºC (-58 ºF) -29 ºC (-20 ºF) 100 ºF (38 ºC) 200 ºF (93 ºC) 0 ºC RT 50 ºC 100 ºC (32 ºF) (122 ºF) (212 ºF) 300 ºF (19 ºC) 150 ºC (302 ºF) 00 ºF (20 ºC) 200 ºC (392 ºF) Permitted operating temperature T Pointek CLS200 Process Pressure/Temperature derating curves (7ML5632 and 7ML562) /38 Siemens FI 01 June 2015

39 Point level measurement - RF Capacitance switches Pointek CLS200 Standard and Digital Pressure/temperature curve CLS200 cable ASME flanged process connections (7ML5631 and 7ML561) Permitted operating pressures P 30 bar (35 psi) 20 bar (290 psi) Atmospheric -1 bar (-1.5 psi) -150 ºC (-238 ºF) -100 ºC (-18 ºF) 10 bar (15 psi) -0 ºF 1 ºF (-0 ºC) (-10 ºC) -50 ºC (-58 ºF) -29 ºC (-20 ºF) 100 ºF (38 ºC) 200 ºF (93 ºC) 0 ºC RT 50 ºC 100 ºC (32 ºF) (122 ºF) (212 ºF) 300 ºF (19 ºC) 150 ºC (302 ºF) 00 ºF (20 ºC) 200 ºC (392 ºF) 500 ºF (260 ºC) 250 ºC (82 ºF) 600 ºF (315 ºC) 300 ºC (572 ºF) 700 ºF (371 ºC) 350 ºC (662 ºF) ASME 150 lb 1) 00 ºC (752 ºF) Permitted operating temperature T 1) The curve denotes the minimum allowable flange class for the shaded area below. Pointek CLS200 Process Pressure/Temperature derating curves (7ML5631 and 7ML561) Pressure/temperature curve CLS200 compact and extended rod ASME flanged process connections (7ML5630 and 7ML560) Permitted operating pressures P 50 bar (725 psi) 0 bar (580 psi) 30 bar (35 psi) ASME 300 lb 1) 20 bar (290 psi) Atmospheric -1 bar (-1.5 psi) -150 ºC (-238 ºF) -100 ºC (-18 ºF) 10 bar (15 psi) -0 ºF 1 ºF (-0 ºC) (-10 ºC) -50 ºC (-58 ºF) -29 ºC (-20 ºF) 100 ºF (38 ºC) 200 ºF (93 ºC) 0 ºC RT 50 ºC 100 ºC (32 ºF) (122 ºF) (212 ºF) 300 ºF (19 ºC) 150 ºC (302 ºF) 00 ºF (20 ºC) 200 ºC (392 ºF) 500 ºF (260 ºC) 250 ºC (82 ºF) 600 ºF (315 ºC) 300 ºC (572 ºF) ASME 150 lb 1) 700 ºF (371 ºC) 350 ºC (662 ºF) 00 ºC (752 ºF) Permitted operating temperature T 1) The curve denotes the minimum allowable flange class for the shaded area below. Pointek CLS200 Process Pressure/Temperature derating curves (7ML5630 and 7ML560) Siemens FI 01 June 2015 /39

40 Point level measurement - RF Capacitance switches Pointek CLS200 Standard and Digital Pressure/temperature curve CLS200 cable EN flanged process connections (7ML5631 and 7ML561) Permitted operating pressures P 30 bar (35 psi) 20 bar (290 psi) Atmospheric -1 bar (-1.5 psi) -150 ºC (-238 ºF) -100 ºC (-18 ºF) 10 bar (15 psi) -0 ºF 1 ºF (-0 ºC) (-10 ºC) -50 ºC (-58 ºF) 100 ºF (38 ºC) 200 ºF (93 ºC) 0 ºC RT 50 ºC 100 ºC (32 ºF) (122 ºF) (212 ºF) 300 ºF (19 ºC) 150 ºC (302 ºF) 00 ºF (20 ºC) 200 ºC (392 ºF) 500 ºF (260 ºC) 250 ºC (82 ºF) 600 ºF (315 ºC) 300 ºC (572 ºF) 700 ºF (371 ºC) 350 ºC (662 ºF) 00 ºC (752 ºF) PN 16 1) -29 ºC (-20 ºF) Permitted operating temperature T 1) The curve denotes the minimum allowable flange class for the shaded area below. Pointek CLS200 Process Pressure/Temperature derating curves (7ML5631 and 7ML561) Pressure/Temperature Curve CLS200 Compact and Extended Rod EN Flanged Process Connections (7ML5630 and 7ML560) Permitted Operating Pressures P 50 bar (725 psi) 0 bar (580 psi) 30 bar (35 psi) 20 bar (290 psi) PN 0 1) Atmospheric -1 bar (-1.5 psi) -150 ºC (-238 ºF) -100 ºC (-18 ºF) 10 bar (15 psi) -0 ºF 1 ºF (-0 ºC) (-10 ºC) -50 ºC (-58 ºF) -29 ºC (-20 ºF) 100 ºF (38 ºC) 200 ºF (93 ºC) 0 ºC RT 50 ºC 100 ºC (32 ºF) (122 ºF) (212 ºF) 300 ºF (19 ºC) 150 ºC (302 ºF) 00 ºF (20 ºC) 200 ºC (392 ºF) 500 ºF (260 ºC) 250 ºC (82 ºF) 600 ºF (315 ºC) 300 ºC (572 ºF) 700 ºF (371 ºC) 350 ºC (662 ºF) PN 16 1) 00 ºC (752 ºF) Permitted Operating Temperature T 1) The curve denotes the minimum allowable flange class for the shaded area below. Pointek CLS200 Process Pressure/Temperature derating curves (7ML5630 and 7ML560) /0 Siemens FI 01 June 2015

41 Point level measurement - RF Capacitance switches Pointek CLS200 Standard and Digital Dimensional drawings Compact version Threaded (7ML5630 and 7ML560) Extended rod version Threaded (7ML5630 and 7ML560) Extended cable version Threaded (7ML5631 and 7ML561) Electronics/ enclosure 120 (.7) 22 (0.87) Sanitary compact version Sanitary fitting (7ML5632 and 7ML562) PPS or optional PVDF probe Y01 (insertion length) 8 (3.3) 316L stainless steel extension Ø20 (0.79) PPS or optional PVDF probe Min. insertion length = 200 (7.87) Max. insertion length = (216) Y01 (insertion length) FEP insulated cable Ø6 (0.3) 316L stainless steel sensor weight Ø20 (0.79) 98 (3.8) 316L stainless steel sanitary process connection PPS or optional PVDF probe 8 (3.3) PPS or optional PVDF probe Min. insertion length = 500 (19.69) Max. insertion length = (1 181) Applicable for liquids and solids applications. Cable can be shortened on site. 2 cable entries ½" NPT or M20 x 1.5 M20: 135 (5.32) ½" NPT: 150 (5.91) Sanitary extended version Sanitary fitting (7ML5632 and 7ML562) Sliding coupling version Threaded (7ML5633 and 7ML563) 16 (6.6) 151 (5.9) Lid with window Lid without window Thermal isolator 239 (9.1) 252 (9.92) Y01 (insertion length) 98 (3.8) 316L stainless steel sanitary process connection 316L stainless steel extension Ø2 (0.95) PPS or optional PVDF probe Min. insertion length = 110 (.3) Max. insertion length = (216) Y01 (insertion length) Min. 215 (8.6) 8 (3.3) 316L stainless steel sliding coupling Ø20 (0.79) PPS or optional PVDF probe Min. insertion length = 350 (13.82) Max. insertion length = (216) Pointek CLS200 - Threaded/sanitary process connections, dimensions in mm (inch) Siemens FI 01 June 2015 /1

42 Point level measurement - RF Capacitance switches Pointek CLS200 Standard and Digital Compact version Welded Flange (7ML5630 and 7ML560) Welded Flange, PFA coated (7ML563 and 7ML56) Extended rod version Welded Flange (7ML5630 and 7ML560) Welded Flange, PFA coated (7ML563 and 7ML56) Extended cable version Welded Flange (7ML5631 and 7ML561) Electronics/ enclosure 98 (3.8) 2 cable entries ½" NPT or M20 x 1.5 PPS or optional PVDF probe M20: 135 (5.32) ½" NPT: 150 (5.91) Y01 (insertion length) 8 (3.3) 316L stainless steel extension (or PFA coated Ø20 (0.79) PPS or optional PVDF probe Min. insertion length = 200 (7.87) Max. insertion length = (216) Y01 (insertion length) FEP insulated cable Ø6 (0.3) 316L stainless steel sensor weight Ø20 (0.79) lid with window 8 (3.3) PPS or optional PVDF probe 16 (6.6) 151 (5.9) Lid without window Thermal isolator 239 (9.1) 252 (9.92) Min. insertion length = 500 (19.69) Max. insertion length = (1 181) Applicable for liquids and solids applications. Cable can be shortened on site. Flange Facing (raised face) Flange Class Facing thickness ASME 150/300 2 (0.08) ASME 600/900 7 (0.28) PN16/0 2 (0.08) Insertion length does not include any raised face/gasket face dimension (see Flange Facing Table above) Pointek CLS200 - Flanged Process Connections, dimensions in mm (inch) /2 Siemens FI 01 June 2015

43 Point level measurement - RF Capacitance switches Pointek CLS200 Standard and Digital Schematics Wiring: Pointek CLS200 standard White Black Red P1 - + Delay Switch bank S1 OFF L2 Output status (+) L1 Sensor status Sensor (f) K1 Trip point GND L3 Power on Power supply 12 to 250 V AC/DC NC NO NO K2 K3 Solid state switch: 30 V DC/30 V AC (peak), 82 ma max. Relay contact: 8 A at 250 V AC, VA 5 A at 30 V DC, 150 W Notes: - Identification label is on underside of lid. Switch and potentiometer settings are for illustration purposes only (refer to operation/setup in manual). - All field wiring must have insulation suitable for at least 250 V. - Relay contact terminals are for use with equipment having no accessible live parts and wiring having insulation suitable for at least 250 V. - Maximum working voltage between adjacent relay contacts shall be 250 V. - Refer to the Instruction Manual or contact Siemens representative for detailed wiring information. P2 K Wiring: Pointek CLS200 Digital Test input White White Reed contact* Red (+) Alarm output solid-state switch Sensor 2 V DC/PROFIBUS PA Black (-) Orange (f) Power connection: 2 V DC or PROFIBUS PA bus (not polarity sensitive). Notes: Refer to the instruction manual or contact a Siemens representative for detailed wiring information. *Magnet activated sensor Test A magnet can be used to test the sensor without opening the lid of the Pointek CLS200 Digital version. Bring the magnet close to the test area indicated on the enclosure. The sensor test starts and finishes automatically after 10 seconds. Pointek CLS200 connections Siemens FI 01 June 2015 /3

44 Point level measurement - RF Capacitance switches Pointek CLS300 - Standard Overview Configuration Installation Pointek CLS300 (standard version) is an inverse frequency shift capacitance level and material detection switch with optional rod/cable choices and configurable output. CLS300 is ideal for detecting liquids, solids, slurries, foam, and interfaces in demanding conditions where high pressure and temperatures are present and has the ability to tune out build-up on the probe. Benefits Active-Shield technology so measurement is unaffected by material buildup or nozzle interference in active shield section Performs in extremely abrasive conditions because of solid rod construction Three LED indicators for adjustment control, output status and power High-temperature version up to 00 C (752 F) Keep unit out of path of falling material, or protect probe from falling material. Build up of material in active shield area does not affect switch operation. Application Pointek CLS300 standard version has three LED indicators with basic relay and solid-state switch alarms. The robust design of CLS300 makes it specifically applicable for heavy solids applications where abrasive materials occur as in the mining industry. The fully potted electronics are unaffected by condensation, dust or vibration. Wetted parts are made of stainless steel with a PFA shield for high chemical resistance, and of ceramic and stainless steel for high temperature version. Materials with low or high dielectric constants can be accurately detected. The unique Active Shield suppresses interference from material buildup or long installation nozzles. The unique modular design of the Pointek CLS300 provides a wide range of configurations, process connections, extensions and approvals to meet the temperature and pressure requirements of specific applications. The modular design makes ordering easier and reduces stocking requirements. A wide range of probe configurations are available, including rod and cable versions. Key Applications: liquids, slurries, bulk solids, relatively high pressure and temperature, hazardous areas, milling and mining applications Install probe at least 50 (2) from tank wall. Note angle of repose and adjust accordingly. Pointek CLS300 installation, dimensions in mm (inch) Min. 50 (2) Min. 50 (2) / Siemens FI 01 June 2015

45 Point level measurement - RF Capacitance switches Pointek CLS300 - Standard Technical specifications Mode of operation Measuring principle Inverse frequency shift capacitive level detection Input Measured variable Change in picofarad (pf) Output Output signal Relay output 1 SPDT Form C relay - Max. contact voltage 30 V DC 250 V AC - Max. contact current 5 A (DC) 8 A (AC) - Max. switching capacity 150 W (DC) VA (AC) - Time delay (ON and/or OFF) s Solid-state output -Output Galvanically isolated -Protection Against reversed polarity (bipolar) - Max. switching voltage 30 V (DC) 30 V peak (AC) - Max. load current 82 ma - Voltage drop < 1 V, typical at 50 ma - Time delay (pre or post switching) s Accuracy Resolution Min. sensitivity (pf) 1 % change in actual capacitance Max. temperature error 0.2 % of actual capacitance value Rated operating conditions 1) Installation conditions Location Indoor/outdoor Ambient conditions Ambient temperature C ( F) 2) Medium conditions Liquids, bulk solids, slurries and interfaces, and applications with viscous materials Relative dielectric constant ε r Min. 1.5 Process temperature - Rod/Cable version C ( F) 2) - High-temperature version C ( F) Process pressure 3) bar g ( psi g) Design Material (enclosure) Degree of Protection Cable inlet Controls and displays Displays Potentiometers Switches Power supply Supply Certificates and approvals General Purpose Flameproof Enclosure with IS Probe Powder-coated aluminum with gasket Standard: Type /NEMA /IP65 Optional: Type /NEMA /IP68 2 x M20x1.5 thread (option: 2 x ½" NPT conduit entry including 1 plugged entry) 3 LEDs, for probe status, output status and power supply 2 potentiometers for time delay and sensitivity 5 DIP switches for delay on/off, fail-safe high/low, time delay test/adjust, high/low sensitivity, test delay settings V AC/DC, Hz, galvanically isolated, 2 W CSA, FM, CE, RCM ATEX II 1/2 G EEx d[ia] IIC T6...T1 ATEX II 1/2 D T100 C Dust Ignition Proof with IS Probe ATEX II 1/2 D T100 C CSA/FM Class II, Div. 1, Groups E, F, G CSA/FM Class III T Explosion Proof Enclosure with IS Probe Marine Overfill Protection Others CSA/FM Class I, Div. 1, Groups A, B, C, D CSA/FM Class II, Div. 1, Groups E, F, G CSA/FM Class III T Lloyds Register of Shipping, Categories ENV1, ENV2 and ENV5 WHG (Germany) VLAREM II (Belgium) Pattern Approval (China) 1) When operation is in areas classified as hazardous, observe restrictions according to relevant certificate. See also Pressure/Temperature curves starting on page /58. 2) Thermal isolator is used if process connection temperature exceeds 85 C (185 F). 3) Pressure rating of process seal is temperature dependent. See Pressure/ Temperature curves starting on page /58. Design: Probe Length Sensor wetted parts Rod version High Temperature version Cable version Min. 250 mm (9.8 inch), max mm (0 inch) PFA (no insulation on active probe), 316L stainless steel, PEEK isolators 1) Zirconium Oxide 2) For Caustic Materials, please contact ceg.smpi@siemens.com for alternative O-rings. Min. 250 mm (9.8 inch), max mm (0 inch) Ceramic (ZrO 1) 2 ) isolators (no insulation on active probe), 316L stainless steel Min mm (0 inch), max mm (98 inch) 316 stainless steel, optional PFA, PEEK isolators O-ring seal material FKM (optional FFKM) 2) Graphite 2) FKM (optional FFKM) 2) Thermal isolator Optional Standard Optional Extension User selectable length User selectable length User selectable cable length Siemens FI 01 June 2015 /5

46 Point level measurement - RF Capacitance switches Pointek CLS300 - Standard Pointek CLS300 - Standard - Rod Version with Threaded or Flanged process connection 7ML Inverse frequency shift capacitance level and material detection switch with optional rod/cable choices and configurable output. CLS300 is ideal for detecting liquids, solids, slurries, foam, and interfaces in demanding conditions where high pressure and temperatures are present, and has the ability to tune out build-up on the probe. Click on the for the online configuration in the PIA Life Cycle Portal. Process connection Threaded, 316L stainless steel ¾" NPT [(Taper), ANSI/ASME B1.20.1] 0 A 1" NPT [(Taper), ANSI/ASME B1.20.1] 0 B 1¼" NPT [(Taper), ANSI/ASME B1.20.1] 0 C 1½" NPT [(Taper), ANSI/ASME B1.20.1] 0 D R ¾" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] 1 A R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] 1 B R 1½" [(BSPT), EN 10226/PT (JIS-T), 1 D JIS B 0203] G ¾" [(BSPP), EN ISO 228-1/PF (JIS-P), 3 A JIS B 0202] G 1" [(BSPP), EN ISO 228-1/PF (JIS-P), 3 B JIS B 0202] G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), 3 D JIS B 0202] Welded flange, 316L stainless steel, raised face 1" ASME, 150 lb 5 A 1" ASME, 300 lb 5 B 1" ASME, 600 lb 5 C 1½" ASME, 150 lb 5 D 1½" ASME, 300 lb 5 E 1½" ASME, 600 lb 5 F 2" ASME, 150 lb 5 G 2" ASME, 300 lb 5 H 2" ASME, 600 lb 5 J 3" ASME, 150 lb 5 K 3" ASME, 300 lb 5 L 3" ASME, 600 lb 5 M " ASME, 150 lb 5 N " ASME, 300 lb 5 P " ASME, 600 lb 5 Q Welded flange, 316L stainless steel, Type A flat faced DN 25, PN 16 6 A DN 25, PN 0 6 B DN 0, PN 16 6 C DN 0, PN 0 6 D DN 50, PN 16 6 E DN 50, PN 0 6 F DN 80, PN 16 6 G DN 80, PN 0 6 H DN 100, PN 16 6 J DN 100, PN 0 6 K (Note: Flange bolting patterns and facings dimensionally correspond to the applicable ASME B16.5 or EN standard.) Probe length (length from flange face) (threaded lengths include process thread) Note: No Y01 needed in Order code for standard lengths Standard version, rod 350 mm (13.78 inch) A Extended rod, length 500 mm (19.69 inch) B Extended rod, length 750 mm (29.53 inch) C Extended rod, length mm (39.37 inch) D Pointek CLS300 - Standard - Rod Version 7ML5650- with Threaded or Flanged process connection Inverse frequency shift capacitance level and material detection switch with optional rod/cable choices and configurable output. CLS300 is ideal for detecting liquids, solids, slurries, foam, and interfaces in demanding conditions where high pressure and temperatures are present, and has the ability to tune out build-up on the probe. Add Order code Y01 and plain text: "Insertion length... mm" Extended rod, factory adjusted length E mm ( inch) Extended rod, factory adjusted length F mm ( inch) Extended rod, factory adjusted length G mm ( inch) Thermal isolator Without thermal isolator 0 With thermal isolator [for process connection 1 temperatures over 85 C (185 F)] Wetted seals FKM 0 FFKM [for process temperatures above 1-20 C (- F)] Probe material 316L stainless steel with PFA lining and PEEK 0 isolators Approvals Dust Ignition Proof with IS Probe: C CE, RCM, ATEX II 1/2 D T100 C Flameproof Enclosure with IS Probe: D CE, RCM, ATEX II 1/2 G EEx d[ia] IIC T6...T1, ATEX II 1/2 D T100 C Flameproof Enclosure with IS Probe, E with WHG approval: CE, RCM, ATEX II 1/2 G EEx d[ia] IIC T6...T1, ATEX II 1/2 D T100 C Dust Ignition Proof with IS Probe: F CSA/FM Class II, Div. 1, Groups E, F, G CSA/FM Class III T Explosion Proof Enclosure with IS Probe: G CSA/FM Class I, Div. 1, Groups A, B, C, D CSA/FM Class II, Div. 1, Groups E, F, G CSA/FM Class III T General Purpose (CSA, FM) H General Purpose (CE, RCM) J General Purpose with WHG approval K (CSA, FM, CE, RCM) Enclosure and lid Aluminum epoxy coated 2 x ½" NPT via adapter - cable inlet, IP65 A 2 x M20x1.5 cable inlet, IP65 B 2 x ½" NPT via adapter - cable inlet, IP68 C 2 x M20x1.5 cable inlet, IP68 D Active shield length Standard length - 0 (125 mm threaded, 105 mm flanged) Extended shield - 1 (250 mm threaded, 230 mm flanged) 1) Extended shield - (00 mm threaded, 380 mm flanged) 2) 2 1) Available with Probe version options B... D, F, G only [ 500 mm (19.69 inch)] 2) Available with Probe version options C, D, and, G only [ 750 mm (29.53 inch)] We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 9/5 in the appendix. /6 Siemens FI 01 June 2015

47 Point level measurement - RF Capacitance switches Pointek CLS300 - Standard Order code Further designs Please add "-Z" to and specify Order code(s). Total insertion length: enter the total insertion length Y01 in plain text description Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Y15 Measuring-point number/identification (max. 27 characters) specify in plain text Manufacturer's test certificate: M to DIN 55350, C11 Part 18 and to ISO 9000 Inspection Certificate Type 3.1 per EN 1020 C12 Operating Instructions Note: The Operating Instructions should be See page /57 ordered as a separate line on the order. This device is shipped with the Siemens Milltronics manual DVD containing the ATEX Quick Start and manual library. Accessories See page /57 We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 9/5 in the appendix. Pointek CLS300 - Standard - Cable Version with Threaded or Flanged process connection 7ML Inverse frequency shift capacitance level and material detection switch with optional rod/cable choices and configurable output. CLS300 is ideal for detecting liquids, solids, slurries, foam, and interfaces in demanding conditions where high pressure and temperatures are present, and has the ability to tune out build-up on the probe. Click on the for the online configuration in the PIA Life Cycle Portal. Process connection Threaded, 316L stainless steel 1¼" NPT [(Taper), ANSI/ASME B1.20.1] 0 C 1½" NPT [(Taper), ANSI/ASME B1.20.1] 0 D R 1½" [(BSPT), EN 10226/PT (JIS-T), 1 D JIS B 0203] G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), 3 D JIS B 0202] Welded flange, 316L stainless steel, raised face 1½" ASME, 150 lb 5 D 1½" ASME, 300 lb 5 E 1½" ASME, 600 lb 5 F 2" ASME, 150 lb 5 G 2" ASME, 300 lb 5 H 2" ASME, 600 lb 5 J 3" ASME, 150 lb 5 K 3" ASME, 300 lb 5 L 3" ASME, 600 lb 5 M " ASME, 150 lb 5 N " ASME, 300 lb 5 P " ASME, 600 lb 5 Q Welded flange, 316L stainless steel, Type A flat faced DN 0, PN 16 6 C DN 0, PN 0 6 D DN 50, PN 16 6 E DN 50, PN 0 6 F DN 80, PN 16 6 G DN 80, PN 0 6 H DN 100, PN 16 6 J DN 100, PN 0 6 K (Note: Flange bolting patterns and facings dimensionally correspond to the applicable ASME B16.5 or EN standard.) Probe length (length from flange face) (threaded lengths include process thread) Note: No Y01 needed in Order code for standard lengths Extended cable, mm ( inch), A length can be shortened by customer Extended cable, mm ( inch), B length can be shortened by customer Add Order code Y01 and plain text: "Insertion length... mm" Extended cable, mm E ( inch) Extended cable, mm F ( inch) Extended cable, mm G ( inch) Extended cable, mm H ( inch) Extended cable, mm J ( inch) Extended cable, mm ( inch) K Siemens FI 01 June 2015 /7

48 Point level measurement - RF Capacitance switches Pointek CLS300 - Standard Pointek CLS300 - Standard - Cable Version 7ML5651- with Threaded or Flanged process connection Inverse frequency shift capacitance level and material detection switch with optional rod/cable choices and configurable output. CLS300 is ideal for detecting liquids, solids, slurries, foam, and interfaces in demanding conditions where high pressure and temperatures are present, and has the ability to tune out build-up on the probe. Thermal isolator Without thermal isolator 0 With thermal isolator [for process connection 1 temperatures over 85 C (185 F)] Wetted seals FKM 0 FFKM [for process temperatures above 1-20 C (- F)] Probe material Bare 316L stainless steel cable, PEEK isolators and 0 316L stainless steel cable weight PFA coated cable, PEEK isolators and 316L 1 stainless steel cable weight Approvals Dust Ignition Proof with IS Probe: C CE, RCM, ATEX II 1/2 D T100 C Flameproof Enclosure with IS Probe: D CE, RCM, ATEX II 1/2 G EEx d[ia] IIC T6...T1, ATEX II 1/2 D T100 C Flameproof Enclosure with IS Probe, E with WHG approval: CE, RCM, ATEX II 1/2 G EEx d[ia] IIC T6...T1, ATEX II 1/2 D T100 C Dust Ignition Proof with IS Probe: F CSA/FM Class II, Div. 1, Groups E, F, G CSA/FM Class III T Explosion Proof Enclosure with IS Probe: G CSA/FM Class I, Div. 1, Groups A, B, C, D CSA/FM Class II, Div. 1, Groups E, F, G CSA/FM Class III T General Purpose (CSA, FM) H General Purpose (CE, RCM) J General Purpose with WHG approval K (CSA, FM, CE, RCM) Enclosure and lid Aluminum epoxy coated 2 x ½" NPT via adapter - cable inlet, IP65 A 2 x M20x1.5 cable inlet, IP65 B 2 x ½" NPT via adapter - cable inlet, IP68 C 2 x M20x1.5 cable inlet, IP68 D Active shield length Standard length - 0 (125 mm threaded, 105 mm flanged) Extended shield - 1 (250 mm threaded, 230 mm flanged) 1) Extended shield - (00 mm threaded, 380 mm flanged) 1) 2 1) Available with Probe version options A, B, F... K, only [ mm (39.7 inch)] We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 9/5 in the appendix. Order code Further designs Please add "-Z" to and specify Order code(s). Total insertion length: enter the total insertion length Y01 in plain text description Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Y15 Measuring-point number/identification (max. 27 characters) specify in plain text Manufacturer's test certificate: M to DIN 55350, C11 Part 18 and to ISO 9000 Inspection Certificate Type 3.1 per EN 1020 C12 Operating Instructions Note: The Operating Instructions should be See page /57 ordered as a separate line on the order. This device is shipped with the Siemens Milltronics manual DVD containing the ATEX Quick Start and manual library. Accessories See page /57 We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 9/5 in the appendix. /8 Siemens FI 01 June 2015

49 Point level measurement - RF Capacitance switches Pointek CLS300 - Standard Pointek CLS300 - Standard - High Temperature Rod Version with Threaded or Flanged process connection 7ML Inverse frequency shift capacitance level and material detection switch with optional rod/cable choices and configurable output. CLS300 is ideal for detecting liquids, solids, slurries, foam, and interfaces in demanding conditions where high pressure and temperatures are present, and has the ability to tune out build-up on the probe. Click on the for the online configuration in the PIA Life Cycle Portal. Process connection Threaded, 316L stainless steel ¾" NPT [(Taper), ANSI/ASME B1.20.1] 0 A 1" NPT [(Taper), ANSI/ASME B1.20.1] 0 B 1¼" NPT [(Taper), ANSI/ASME B1.20.1] 0 C 1½" NPT [(Taper), ANSI/ASME B1.20.1] 0 D R ¾" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] 1 A R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] 1 B R 1½" [(BSPT), EN 10226/PT (JIS-T), 1 D JIS B 0203] G ¾" [(BSPP), EN ISO 228-1/PF (JIS-P), 3 A JIS B 0202] G 1" [(BSPP), EN ISO 228-1/PF (JIS-P), 3 B JIS B 0202] G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), 3 D JIS B 0202] Welded flange, 316L stainless steel, raised face 1" ASME, 150 lb 5 A 1" ASME, 300 lb 5 B 1" ASME, 600 lb 5 C 1½" ASME, 150 lb 5 D 1½" ASME, 300 lb 5 E 1½" ASME, 600 lb 5 F 2" ASME, 150 lb 5 G 2" ASME, 300 lb 5 H 2" ASME, 600 lb 5 J 3" ASME, 150 lb 5 K 3" ASME, 300 lb 5 L 3" ASME, 600 lb 5 M " ASME, 150 lb 5 N " ASME, 300 lb 5 P " ASME, 600 lb 5 Q Welded flange, 316L stainless steel, Type A flat faced DN 25, PN 16 6 A DN 25, PN 0 6 B DN 0, PN 16 6 C DN 0, PN 0 6 D DN 50, PN 16 6 E DN 50, PN 0 6 F DN 80, PN 16 6 G DN 80, PN 0 6 H DN 100, PN 16 6 J DN 100, PN 0 6 K (Note: Flange bolting patterns and facings dimensionally correspond to the applicable ASME B16.5 or EN standard.) Probe length (length from flange face) (threaded lengths include process thread) Note: No Y01 needed in Order code for standard lengths Standard version rod 350 mm (13.78 inch) A Extended rod, length 500 mm (19.69 inch) B Extended rod, length 750 mm (29.53 inch) C Extended rod, length mm (39.37 inch) D Pointek CLS300 - Standard - High Temperature 7ML5652- Rod Version with Threaded or Flanged process connection Inverse frequency shift capacitance level and material detection switch with optional rod/cable choices and configurable output. CLS300 is ideal for detecting liquids, solids, slurries, foam, and interfaces in demanding conditions where high pressure and temperatures are present, and has the ability to tune out build-up on the probe. Add Order code Y01 and plain text: "Insertion length... mm" Extended rod, factory adjusted length E mm ( inch) Extended rod, factory adjusted length F mm ( inch) Extended rod, factory adjusted length G mm ( inch) Wetted seals Graphite 0 Probe material 316L stainless steel with ceramic (ZrO 2 ) isolators 0 Approvals Dust Ignition Proof with IS Probe: C CE, RCM, ATEX II 1/2 D T100 C Flameproof Enclosure with IS Probe: D CE, RCM, ATEX II 1/2 G EEx d[ia] IIC T6...T1, ATEXII 1/2 D T100 C Flameproof Enclosure with IS Probe, E with WHG approval: CE, RCM, ATEX II 1/2 G EEx d[ia] IIC T6...T1, ATEX II 1/2 D T100 C Dust Ignition Proof with IS Probe: F CSA/FM Class II, Div. 1, Groups E, F, G CSA/FM Class III T Explosion Proof Enclosure with IS Probe: G CSA/FM Class I, Div. 1, Groups A, B, C, D CSA/FM Class II, Div. 1, Groups E, F, G CSA/FM Class III T General Purpose (CSA, FM) H General Purpose (CE, RCM) J General Purpose with WHG approval K (CSA, FM, CE, RCM) Enclosure and lid Aluminum epoxy coated 2 x ½" NPT via adapter - cable inlet, IP65 A 2 x M20x1.5 cable inlet, IP65 B 2 x ½" NPT via adapter - cable inlet, IP68 C 2 x M20x1.5 cable inlet, IP68 D Active shield length Standard length - 0 (125 mm threaded, 105 mm flanged) Extended shield - 1 (250 mm threaded, 230 mm flanged) 1) Extended shield - (00 mm threaded, 380 mm flanged) 2) 2 1) Available with Probe version options B... D, F, G only [ 500 mm (19.69 inch)] 2) Available with Probe version options C, D, and, G only [ 750 mm (29.53 inch)] We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 9/5 in the appendix. Siemens FI 01 June 2015 /9

50 Point level measurement - RF Capacitance switches Pointek CLS300 - Standard Order code Further designs Please add "-Z" to and specify Order code(s). Total insertion length: enter the total insertion length Y01 in plain text description Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Y15 Measuring-point number/identification (max. 27 characters) specify in plain text Manufacturer's test certificate: M to DIN 55350, C11 Part 18 and to ISO 9000 Inspection Certificate Type 3.1 per EN 1020 C12 Operating Instructions Note: The Operating Instructions should be See page /57 ordered as a separate line on the order. This device is shipped with the Siemens Milltronics manual DVD containing the ATEX Quick Start and manual library. Accessories See page /57 We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 9/5 in the appendix. /50 Siemens FI 01 June 2015

51 Point level measurement - RF Capacitance switches Pointek CLS300 - Digital Overview Configuration Installation Pointek CLS300 (digital version) is an inverse frequency shift capacitance level and material detection switch with optional rod/cable choices and configurable output. It is ideal for detecting liquids, solids, slurries, foam and interfaces in demanding conditions where high pressure and temperatures are present and has the ability to tune out build-up on the probe. The digital version includes PROFIBUS PA, an LCD display, and advanced diagnostic features. Benefits Active-Shield technology so measurement is unaffected by material buildup or nozzle interference in active shield section Performs in extremely abrasive conditions because of solid rod construction Push-button calibration, full-function diagnostics High sensitivity allows installation in a wide range of liquids, solids or slurry applications Integral LCD display allows for easy menu-driven setup PROFIBUS PA communication (SIMATIC PDM compatible) Keep unit out of path of falling material, or protect probe from falling material. Build up of material in active shield area does not affect switch operation. Application Pointek CLS300 digital version provides an integral LCD display for stand-alone use, with PROFIBUS PA communication (Profile version 3.0, Class B) when required. Solid-state switch alarm is standard. The robust design of CLS300 makes it specifically applicable for heavy solids applications where abrasive materials occur as in the mining industry. The fully potted electronics are unaffected by condensation, dust or vibration. Wetted parts are made of stainless steel with a PFA shield for high chemical resistance, and of ceramic and stainless steel for high temperature version. Materials with low or high dielectric constants can be accurately detected. The unique Active Shield suppresses interference from material buildup or long installation nozzles. The unique modular design of the Pointek CLS300 provides a wide range of configurations, process connections, extensions and approvals to meet the temperature and pressure requirements of specific applications. The modular design makes ordering easier and reduces stocking requirements. A wide range of probe configurations are available, including rod and cable versions. Key Applications: liquids, slurries, bulk solids, relatively high pressure and temperature, hazardous areas, milling and mining applications Install probe at least 50 (2) from tank wall. Note angle of repose and adjust accordingly. Pointek CLS300 installation, dimensions in mm (inch) Min. 50 (2) Min. 50 (2) Siemens FI 01 June 2015 /51

52 Point level measurement - RF Capacitance switches Pointek CLS300 - Digital Technical specifications Mode of operation Measuring principle Inverse frequency shift capacitive level detection Input Measured variable Change in picofarad (pf) Output Solid-state output Output Galvanically isolated Protection Against reversed polarity (bipolar) Max. switching voltage 30 V (DC) 30 V peak (AC) Max. load current 82 ma Voltage drop < 1 V, typical at 50 ma Time delay (pre or post switching) Programmable by user ( s) Fail-safe mode Min. or max. Connection Removable terminal block Accuracy Resolution Min. sensitivity (pf) 1 % change in actual capacitance Max. temperature error 0.2 % of actual capacitance value Rated operating conditions 1) Installation conditions Location Indoor/outdoor Ambient conditions Ambient temperature C ( F) 2) Medium conditions Liquids, bulk solids, slurries and interfaces, and applications with viscous materials Relative dielectric constant ε r Min. 1.5 Process temperature - Rod/Cable version C ( F) 2) - High Temperature version C ( F) Process pressure 3) bar g ( psi g) Design Material (enclosure) Powder-coated aluminum with gasket Degree of protection Standard: Type /NEMA /IP65 Optional: Type /NEMA /IP68 Cable inlet 2 x M20x1.5 thread (option: 2 x ½" NPT conduit entry including 1 plugged entry) Controls and displays Local display LCD Configuration Locally, using 3 button keypad (for standalone operation) Remotely, using SIMATIC PDM (for installation on a network) Power supply Bus voltage (at process connection) Standard: V DC Intrinsically Safe: V DC 12.5 ma Current consumption Certificates and approvals General Purpose CSA, FM, CE, RCM Dust Ignition Proof ATEX II 1/2 D, 2 D IP6X T100 C Flameproof Enclosure With IS Probe ATEX II 1/2 G EEx d[ia] IIC T6...T ATEX II 1/2 D T100 C Dust Ignition Proof With IS Probe CSA/FM Class II, Div. 1, Groups E, F, G CSA/FM Class III T Intrinsically Safe ) ATEX II 1 G EEx ia IIC T6...T ATEX II 1/2 D, 2 D IP6X T100 C CSA/FM Class I, Div. 1, Groups A, B, C, D CSA/FM Class II, Div. 1, Groups E, F, G CSA/FM Class III T Non-incendive CSA/FM Class I, Div. 2, Groups A, B, C, D CSA/FM Class II, Div. 2, Groups F, G CSA/FM Class III T or T6 Explosion Proof with IS Probe CSA/FM Class I, Div. 1, Groups A, B, C, D CSA/FM Class II, Div. 1, Groups E, F, G CSA/FM Class III T Marine Lloyds Register of Shipping, Categories ENV1, ENV2 and ENV5 Others Pattern Approval (China) Communication PROFIBUS PA (IEC CPF3 CP3/2) Bus physical layer: IEC MBP-(IS) Device profile: PROFIBUS PA profile for Process Control Devices Version 3.0, Class B FISCO field device 1) When operation is in areas classified as hazardous, observe restrictions according to relevant certificate. See also Pressure/Temperature curves starting on page /58. 2) Thermal isolator is used if process connection temperature exceeds 85 C (185 F) 3) Pressure rating of process seal is temperature dependent. See Pressure/Temperature curves starting on page /58. ) Barrier or Intrinsically Safe power supply required for Intrinsically Safe protection Design: Probe Length Sensor wetted parts Rod version High Temperature version Cable version Min. 250 mm (9.8 inch), max mm (0 inch) PFA (no insulation on active probe), 316L stainless steel, PEEK isolators 1) Zirconium Oxide 2) For Caustic Materials, please contact ceg.smpi@siemens.com for alternative O-rings Min. 250 mm (9.8 inch), max mm (0 inch) Ceramic (ZrO 1) 2 ) isolators (no insulation on active probe), 316L stainless steel Min mm (0 inch), max mm (98 inch) 316 stainless steel, optional PFA, PEEK isolators O-ring seal material FKM (optional FFKM) 2) Graphite 2) FKM (optional FFKM) 2) Thermal isolator Optional Standard Optional Extension User selectable length User selectable length User selectable cable length /52 Siemens FI 01 June 2015

53 Point level measurement - RF Capacitance switches Pointek CLS300 - Digital Pointek CLS300 - Digital - Rod with Threaded or Flanged process connection Inverse frequency shift capacitance level and material detection switch with optional rod/cable choices and configurable output. It is ideal for detecting liquids, solids, slurries, foam, and interfaces in demanding conditions where high pressure and temperatures are present and has the ability to tune out build-up on the probe. Click on the for the online configuration in the PIA Life Cycle Portal. Process connection Threaded, 316L stainless steel ¾" NPT [(Taper), ANSI/ASME B1.20.1] 0 A 1" NPT [(Taper), ANSI/ASME B1.20.1] 0 B 1¼" NPT [(Taper), ANSI/ASME B1.20.1] 0 C 1½" NPT [(Taper), ANSI/ASME B1.20.1] 0 D R ¾" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] 1 A R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] 1 B R 1½" [(BSPT), EN 10226/PT (JIS-T), 1 D JIS B 0203] G ¾" [(BSPP), EN ISO 228-1/PF (JIS-P), 3 A JIS B 0202] G 1" [(BSPP), EN ISO 228-1/PF (JIS-P), 3 B JIS B 0202] G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), 3 D JIS B 0202] Welded flange, 316L stainless steel, raised face 1" ASME, 150 lb 5 A 1" ASME, 300 lb 5 B 1" ASME, 600 lb 5 C 1½" ASME, 150 lb 5 D 1½" ASME, 300 lb 5 E 1½" ASME, 600 lb 5 F 2" ASME, 150 lb 5 G 2" ASME, 300 lb 5 H 2" ASME, 600 lb 5 J 3" ASME, 150 lb 5 K 3" ASME, 300 lb 5 L 3" ASME, 600 lb 5 M " ASME, 150 lb 5 N " ASME, 300 lb 5 P " ASME, 600 lb 5 Q Welded flange, 316L stainless steel, Type A flat faced DN 25, PN 16 6 A DN 25, PN 0 6 B DN 0, PN 16 6 C DN 0, PN 0 6 D DN 50, PN 16 6 E DN 50, PN 0 6 F DN 80, PN 16 6 G DN 80, PN 0 6 H DN 100, PN 16 6 J DN 100, PN 0 6 K (Note: Flange bolting patterns and facings dimensionally correspond to the applicable ASME B16.5 or EN standard.) Probe length (length from flange face) (threaded lengths include process thread) Note: No Y01 needed in Order code for standard lengths Standard version, rod 350 mm (13.78 inch) A Extended rod, length 500 mm (19.69 inch) B Extended rod, length 750 mm (29.53 inch) C Extended rod, length mm (39.37 inch) D 7ML Pointek CLS300 - Digital - Rod with Threaded or Flanged process connection 7ML Inverse frequency shift capacitance level and material detection switch with optional rod/cable choices and configurable output. It is ideal for detecting liquids, solids, slurries, foam, and interfaces in demanding conditions where high pressure and temperatures are present and has the ability to tune out build-up on the probe. Add Order code Y01 and plain text: "Insertion length... mm" Extended rod, factory adjusted length E mm ( inch) Extended rod, factory adjusted length F mm ( inch) Extended rod, factory adjusted length G mm ( inch) Thermal isolator Without thermal isolator 0 With thermal isolator [for process connection 1 temperatures over 85 C (185 F)] Wetted seals FKM 0 FFKM [for process temperatures above -20 C (- F)] 1 Probe material 316L stainless steel with PFA lining and PEEK 0 isolators Approvals Dust Ignition Proof: B CE, RCM, ATEX II 1/2 D, 2 D IP6X T100 C Intrinsically Safe 1) C CE, RCM, ATEX II 1 G EEx ia IIC T6...T, ATEX II 1/2 D, 2 D IP6X T100 C Flameproof Enclosure with IS Probe: D CE, RCM, ATEX II 1/2 G EEx d[ia] IIC T6...T, ATEX II 1/2 D T100 C Dust Ignition Proof with IS Probe: E CSA/FM Class II, Div. 1, Groups E, F, G CSA/FM Class III T Intrinsically Safe 1) F CSA/FM Class I, Div. 1, Groups A, B, C, D CSA/FM Class II, Div. 1, Groups E, F, G CSA/FM Class III T Explosion Proof Enclosure with IS Probe: G CSA/FM Class I, Div. 1, Groups A, B, C, D CSA/FM Class II, Div. 1, Groups E, F, G CSA/FM Class III T General Purpose (CSA, FM) H General Purpose (CSA, FM, CE, RCM) J We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 9/5 in the appendix. Siemens FI 01 June 2015 /53

54 Point level measurement - RF Capacitance switches Pointek CLS300 - Digital Pointek CLS300 - Digital - Rod with 7ML5660- Threaded or Flanged process connection Inverse frequency shift capacitance level and material detection switch with optional rod/cable choices and configurable output. It is ideal for detecting liquids, solids, slurries, foam, and interfaces in demanding conditions where high pressure and temperatures are present and has the ability to tune out build-up on the probe. Enclosure and Lid Aluminum epoxy coated 2 x ½" NPT via adapter - cable inlet, IP65 A 2 x M20x1.5 cable inlet, IP65 B 2 x ½" NPT via adapter - cable inlet, IP68 C 2 x M20x1.5 cable inlet, IP68 D Active shield length Standard length - 0 (125 mm threaded, 105 mm flanged) Extended shield - 1 (250 mm threaded, 230 mm flanged) 2) Extended shield - (00 mm threaded, 380 mm flanged) 3) 2 1) Barrier or Intrinsically Safe power supply required for Intrinsically Safe protection 2) Available with Probe version options B... D, F, G only [ 500 mm (19.69 inch)] 3) Available with Probe version options C, D, and, G only [ 750 mm (29.53 inch)] We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 9/5 in the appendix. Order code Further designs Please add "-Z" to and specify Order code(s). Total insertion length: enter the total insertion length Y01 in plain text description Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Y15 Measuring-point number/identification (max. 27 characters) specify in plain text Manufacturer's test certificate: M to DIN 55350, C11 Part 18 and to ISO 9000 Inspection Certificate Type 3.1 per EN 1020 C12 Operating Instructions Note: The Operating Instructions should be See page /57 ordered as a separate line on the order. This device is shipped with the Siemens Milltronics manual DVD containing the ATEX Quick Start and manual library. Accessories See page /57 We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 9/5 in the appendix. Pointek CLS300 - Digital - Cable with Threaded or Flanged process connection 7ML Inverse frequency shift capacitance level and material detection switch with optional rod/cable choices and configurable output. It is ideal for detecting liquids, solids, slurries, foam, and interfaces in demanding conditions where high pressure and temperatures are present and has the ability to tune out build-up on the probe. Click on the for the online configuration in the PIA Life Cycle Portal. Process connection Threaded, 316L stainless steel 1¼" NPT [(Taper), ANSI/ASME B1.20.1] 0 C 1½" NPT [(Taper), ANSI/ASME B1.20.1] 0 D R 1½" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] 1 D G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] 3 D Welded flange, 316L stainless steel, raised face 1½" ASME, 150 lb 5 D 1½" ASME, 300 lb 5 E 1½" ASME, 600 lb 5 F 2" ASME, 150 lb 5 G 2" ASME, 300 lb 5 H 2" ASME, 600 lb 5 J 3" ASME, 150 lb 5 K 3" ASME, 300 lb 5 L 3" ASME, 600 lb 5 M " ASME, 150 lb 5 N " ASME, 300 lb 5 P " ASME, 600 lb 5 Q Welded flange, 316L stainless steel, Type A flat faced DN 0, PN 16 6 C DN 0, PN 0 6 D DN 50, PN 16 6 E DN 50, PN 0 6 F DN 80, PN 16 6 G DN 80, PN 0 6 H DN 100, PN 16 6 J DN 100, PN 0 6 K (Note: Flange bolting patterns and facings dimensionally correspond to the applicable ASME B16.5 or EN standard.) Probe length (length from flange face) (threaded lengths include process thread) Note: No Y01 needed in Order code for standard lengths Extended cable, mm ( inch), A length can be shortened by customer Extended cable, mm ( inch), B length can be shortened by customer Add Order code Y01 and plain text: "Insertion length... mm" Extended cable, mm E ( inch) Extended cable, mm F ( inch) Extended cable, mm G ( inch) Extended cable, mm H ( inch) Extended cable, mm J ( inch) Extended cable, mm ( inch) K /5 Siemens FI 01 June 2015

55 Point level measurement - RF Capacitance switches Pointek CLS300 - Digital Pointek CLS300 - Digital - Cable with 7ML5661- Threaded or Flanged process connection Inverse frequency shift capacitance level and material detection switch with optional rod/cable choices and configurable output. It is ideal for detecting liquids, solids, slurries, foam, and interfaces in demanding conditions where high pressure and temperatures are present and has the ability to tune out build-up on the probe. Thermal isolator Without thermal isolator 0 With thermal isolator [for process connection 1 temperatures over 85 C (185 F)] Wetted seals FKM 0 FFKM [for process temperatures above -20 C (- F)] 1 Probe material Bare 316L stainless steel cable, PEEK isolators and 0 316L stainless steel cable weight PFA coated cable, PEEK isolators and 316L 1 stainless steel cable weight Approvals Dust Ignition Proof: B CE, RCM, ATEX II 1/2 D, 2 D IP6X T100 C Intrinsically Safe 1) C CE, RCM, ATEX II 1 G EEx ia IIC T6... T, ATEX II 1/2 D, 2 D IP6X T100 C Flameproof Enclosure with IS Probe: D CE, RCM, ATEX II 1/2 G EEx d[ia] IIC T6... T, ATEX II 1/2 D T100 C Intrinsically Safe 1) F CSA/FM Class I, Div. 1, Groups A, B, C, D CSA/FM Class II, Div. 1, Groups E, F, G CSA/FM Class III T Explosion Proof Enclosure with IS Probe: G CSA/FM Class I, Div. 1, Groups A, B, C, D CSA/FM Class II, Div. 1, Groups E, F, G CSA/FM Class III T General Purpose (CSA, FM) H General Purpose (CSA, FM, CE, RCM) J Enclosure and Lid Aluminum epoxy coated 2 x ½" NPT via adapter - cable inlet, IP65 A 2 x M20x1.5 cable inlet, IP65 B 2 x ½" NPT via adapter - cable inlet, IP68 C 2 x M20x1.5 cable inlet, IP68 D Active shield length Standard length - 0 (125 mm threaded, 105 mm flanged) Extended shield mm threaded, 230 mm flanged) 2) Extended shield - (00 mm threaded, 380 mm flanged) 2) 2 1) Barrier or Intrinsically Safe power supply required for Intrinsically Safe protection 2) Available with Probe version options A, B and, F... K only [ mm (39.7 inch)] We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 9/5 in the appendix. Order code Further designs Please add "-Z" to and specify Order code(s). Total insertion length: enter the total insertion length Y01 in plain text description Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Y15 Measuring-point number/identification (max. 27 characters) specify in plain text Manufacturer's test certificate: M to DIN 55350, C11 Part 18 and to ISO 9000 Inspection Certificate Type 3.1 per EN 1020 C12 Operating Instructions Note: The Operating Instructions should be See page /57 ordered as a separate line on the order. This device is shipped with the Siemens Milltronics manual DVD containing the ATEX Quick Start and manual library. Accessories See page /57 We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 9/5 in the appendix. Siemens FI 01 June 2015 /55

56 Point level measurement - RF Capacitance switches Pointek CLS300 - Digital Pointek CLS300 - Digital - High Temperature Rod version with Threaded or Flanged process connection Inverse frequency shift capacitance level and material detection switch with optional rod/cable choices and configurable output. It is ideal for detecting liquids, solids, slurries, foam, and interfaces in demanding conditions where high pressure and temperatures are present and has the ability to tune out build-up on the probe. Click on the for the online configuration in the PIA Life Cycle Portal. Process connection Threaded, 316L stainless steel ¾" NPT [(Taper), ANSI/ASME B1.20.1] 0 A 1" NPT [(Taper), ANSI/ASME B1.20.1] 0 B 1¼" NPT [(Taper), ANSI/ASME B1.20.1] 0 C 1½" NPT [(Taper), ANSI/ASME B1.20.1] 0 D R ¾" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] 1 A R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] 1 B R 1½" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] G ¾" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] G 1" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] Welded flange, 316L stainless steel, raised face 7ML D A 3 B 3 D 1" ASME, 150 lb 5 A 1" ASME, 300 lb 5 B 1" ASME, 600 lb 5 C 1½" ASME, 150 lb 5 D 1½" ASME, 300 lb 5 E 1½" ASME, 600 lb 5 F 2" ASME, 150 lb 5 G 2" ASME, 300 lb 5 H 2" ASME, 600 lb 5 J 3" ASME, 150 lb 5 K 3" ASME, 300 lb 5 L 3" ASME, 600 lb 5 M " ASME, 150 lb 5 N " ASME, 300 lb 5 P " ASME, 600 lb 5 Q Welded flange, 316L stainless steel, Type A flat faced DN 25, PN 16 DN 25, PN 0 DN 0, PN 16 DN 0, PN 0 DN 50, PN 16 DN 50, PN 0 DN 80, PN 16 DN 80, PN 0 DN 100, PN 16 DN 100, PN 0 (Note: Flange bolting patterns and facings dimensionally correspond to the applicable ASME B16.5 or EN standard.) 6 A 6 B 6 C 6 D 6 E 6 F 6 G 6 H 6 J 6 K Probe length (length from flange face) (threaded lengths include process thread) Note: No Y01 needed in Order code for standard lengths Standard version, rod 350 mm (13.78 inch) A Extended rod, length 500 mm (19.69 inch) B Extended rod, length 750 mm (29.53 inch) C Extended rod, length mm (39.37 inch) D Pointek CLS300 - Digital - High Temperature Rod version with Threaded or Flanged process connection Inverse frequency shift capacitance level and material detection switch with optional rod/cable choices and configurable output. It is ideal for detecting liquids, solids, slurries, foam, and interfaces in demanding conditions where high pressure and temperatures are present and has the ability to tune out build-up on the probe. Add Order code Y01 and plain text: "Insertion length... mm" Extended rod, factory adjusted length mm ( inch) Extended rod, factory adjusted length mm ( inch) Extended rod, factory adjusted length mm ( inch) Wetted seals Graphite 0 Probe material 316L stainless steel with ceramic (ZrO 2 ) isolators 0 Approvals Dust Ignition Proof: CE, RCM, ATEX II 1/2 D, 2 D IP6X T100 C Intrinsically Safe 1) CE, RCM, ATEX II 1 G EEx ia IIC T6...T, ATEX II 1/2 D, 2 D IP6X T100 C Flameproof Enclosure with IS Probe: CE, RCM, ATEX II 1/2 G EEx d[ia] IIC T6...T, D ATEX II 1/2 D T100 C Intrinsically Safe 1) CSA/FM Class I, Div. 1, Groups A, B, C, D F CSA/FM Class II, Div. 1, Groups E, F, G CSA/FM Class III T Explosion Proof Enclosure with IS Probe: CSA/FM Class I, Div. 1, Groups A, B, C, D G CSA/FM Class II, Div. 1, Groups E, F, G CSA/FM Class III T General Purpose (CSA, FM) H General Purpose (CSA, FM, CE, RCM) J Enclosure and Lid Aluminum epoxy coated 2 x ½" NPT via adapter - cable inlet, IP65 A 2 x M20x1.5 cable inlet, IP65 B 2 x ½" NPT via adapter - cable inlet, IP68 C 2 x M20x1.5 cable inlet, IP68 D Active shield length Standard length - 0 (125 mm threaded, 105 mm flanged) Extended shield - 1 (250 mm threaded, 230 mm flanged) 2) Extended shield - (00 mm threaded, 380 mm flanged) 3) 2 We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 9/5 in the appendix. 7ML ) Barrier or Intrinsically Safe power supply required for Intrinsically Safe protection 2) Available with Probe version options B... D, F, G only [ 500 mm (19.69 inch)] 3) Available with Probe version options C, D, and, G only [ 750 mm (29.53 inch)] E F G B C /56 Siemens FI 01 June 2015

57 Point level measurement - RF Capacitance switches Pointek CLS300 Standard and Digital Order code Further designs Please add "-Z" to and specify Order code(s). Total insertion length: enter the total insertion length Y01 in plain text description Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Y15 Measuring-point number/identification (max. 27 characters) specify in plain text Manufacturer's test certificate: M to DIN 55350, C11 Part 18 and to ISO 9000 Inspection Certificate Type 3.1 per EN 1020 C12 Operating Instructions Note: The Operating Instructions should be See page /57 ordered as a separate line on the order. This device is shipped with the Siemens Milltronics manual DVD containing the ATEX Quick Start and manual library. Accessories See page /57 We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 9/5 in the appendix. Operating Instructions - Standard English 7ML1998-5JH0 German 7ML1998-5JH3 Note: The Operating Instructions should be ordered as a separate line on the order. Quick Start manual, multi-language A5E This device is shipped with the Siemens Milltronics manual DVD containing the ATEX Quick Start and Operating Instructions library. Operating Instructions - Digital English 7ML1998-5JJ05 French 7ML1998-5JJ11 German 7ML1998-5JJ3 Note: The Operating Instructions should be ordered as a separate line on the order. Quick Start manual, multi-language A5E This device is shipped with the Siemens Milltronics manual DVD containing the ATEX Quick Start and Operating Instructions library. Accessories One metallic cable gland M20x1.5, C 7ML1930-1AQ ( F) with integrated shield connection (available for PROFIBUS PA) General Purpose 1/2" NPT General Purpose Cable Entry IP68/IP69K 7ML1830-1JA NEMA6, C ( F), cable size mm ( inch) M20x1.5 General Purpose Cable Entry IP68/IP69K 7ML1830-1JC NEMA6, C ( F), cable size mm ( inch) Hazardous Locations 1/2" NPT EMC rated Cable Gland: Dust Ignition Proof, 7ML1830-1JB Flameproof Exd, and Increased Safety ATEX II 2 GD ExtD A21 (Zone 1, Zone 2, Zone 21, Zone 22, and in Gas Groups IIA,IIB and IIC) C IP66, IP67, IP68, NEMAX, cable sizes mm ( inch) M20 EMC rated Cable Gland: Dust Ignition Proof, 7ML1830-1JD Flameproof Exd, and Increased Safety ATEX II 2 GD ExtD A21 (Zone 1, Zone 2, Zone 21, Zone 22 and in Gas Groups IIA,IIB and IIC) C IP66, IP67, IP68, NEMAX, cable sizes mm ( inch) Blind threaded flanges are available. Please contact ceg.smpi@siemens.com with a completed application data sheet on page /11 Pointek Specials See page /80 Siemens FI 01 June 2015 /57

58 Point level measurement - RF Capacitance switches Pointek CLS300 Standard and Digital Characteristic curves Pressure/temperature curve CLS300 extended rod and cable probes Threaded process connections (7ML5650, 7ML5651, 7ML5660 and 7ML5661) Permitted operating pressures P 0 bar (580 psi) 30 bar (35 psi) Atmospheric -1 bar (-1.5 psi) -150 ºC (-238 ºF) -100 ºC (-18 ºF) 20 bar (290 psi) 10 bar (15 psi) -0 ºF 1 ºF (-0 ºC) (-10 ºC) -50 ºC (-58 ºF) -29 ºC (-20 ºF) 100 ºF (38 ºC) 200 ºF (93 ºC) 0 ºC RT 50 ºC 100 ºC (32 ºF) (122 ºF) (212 ºF) 300 ºF (19 ºC) 150 ºC (302 ºF) 00 ºF (20 ºC) 200 ºC (392 ºF) 500 ºF (260 ºC) 250 ºC (82 ºF) 600 ºF (315 ºC) 300 ºC (572 ºF) 700 ºF (371 ºC) 350 ºC (662 ºF) 00 ºC (752 ºF) Permitted operating temperature T Example: Permitted operating pressure = 30 bar (35 psi) at 75 C Pointek CLS300 Process Pressure/Temperature derating curves (7ML5650, 7ML5651, 7ML5660 and 7ML5661) Pressure/temperature curve CLS300 high temperature rod probes Threaded process connections (7ML5652 and 7ML5662) Permitted operating pressures P 0 bar (580 psi) 30 bar (35 psi) 20 bar (290 psi) Atmospheric -1 bar (-1.5 psi) -150 ºC (-238 ºF) -100 ºC (-18 ºF) 10 bar (15 psi) -0 ºF 1 ºF (-0 ºC) (-10 ºC) -50 ºC (-58 ºF) -29 ºC (-20 ºF) 100 ºF (38 ºC) 200 ºF (93 ºC) 0 ºC RT 50 ºC 100 ºC (32 ºF) (122 ºF) (212 ºF) 300 ºF (19 ºC) 150 ºC (302 ºF) 00 ºF (20 ºC) 200 ºC (392 ºF) 500 ºF (260 ºC) 250 ºC (82 ºF) 600 ºF (315 ºC) 300 ºC (572 ºF) 700 ºF (371 ºC) 350 ºC (662 ºF) 00 ºC (752 ºF) Permitted operating temperature T Pointek CLS300 Process Pressure/Temperature derating curves (7ML5652 and 7ML5662) /58 Siemens FI 01 June 2015

59 Point level measurement - RF Capacitance switches Pointek CLS300 Standard and Digital Pressure/temperature curve CLS300 extended rod and cable probes ASME flanged process connections (7ML5650, 7ML5651, 7ML5660 and 7ML5661) Permitted operating pressures P 50 bar (725 psi) 0 bar (580 psi) Atmospheric -1 bar (-1.5 psi) -150 ºC (-238 ºF) -100 ºC (-18 ºF) 30 bar (35 psi) 20 bar (290 psi) 10 bar (15 psi) -0 ºF 1 ºF (-0 ºC) (-10 ºC) -50 ºC (-58 ºF) -29 ºC (-20 ºF) 100 ºF (38 ºC) 200 ºF (93 ºC) 0 ºC RT 50 ºC 100 ºC (32 ºF) (122 ºF) (212 ºF) 300 ºF (19 ºC) 150 ºC (302 ºF) 00 ºF (20 ºC) 200 ºC (392 ºF) 500 ºF (260 ºC) 250 ºC (82 ºF) 600 ºF (315 ºC) 300 ºC (572 ºF) ASME 150 lb 1) 700 ºF (371 ºC) 350 ºC (662 ºF) ASME 300 lb 1) 00 ºC (752 ºF) Permitted operating temperature T 1) The curve denotes the minimum allowable flange class for the shaded area below. Pointek CLS300 Process Pressure/Temperature derating curves (7ML5650, 7ML5651, 7ML5660, and 7ML5661) Permitted operating pressures P 90 bar (1.305 psi) Pressure/temperature curve CLS300 high temperature rod probes ASME flanged process connections (7ML5652 and 7ML5662) 80 bar (1.160 psi) 70 bar (1.015 psi) 60 bar (870 psi) ASME 600 lb 1) 50 bar (725 psi) 0 bar (580 psi) 30 bar (35 psi) ASME 300 lb 1) 20 bar (290 psi) Atmospheric -1 bar (-1.5 psi) -150 ºC (-238 ºF) -100 ºC (-18 ºF) 10 bar (15 psi) -0 ºF 1 ºF (-0 ºC) (-10 ºC) -50 ºC (-58 ºF) -29 ºC (-20 ºF) 100 ºF (38 ºC) 200 ºF (93 ºC) 0 ºC RT 50 ºC 100 ºC (32 ºF) (122 ºF) (212 ºF) 300 ºF (19 ºC) 150 ºC (302 ºF) 00 ºF (20 ºC) 200 ºC (392 ºF) 500 ºF (260 ºC) 250 ºC (82 ºF) 600 ºF (315 ºC) 300 ºC (572 ºF) 700 ºF (371 ºC) 350 ºC (662 ºF) ASME 150 lb 1) 00 ºC (752 ºF) Permitted operating temperature T 1) The curve denotes the minimum allowable flange class for the shaded area below. Pointek CLS300 Process Pressure/Temperature derating curves (7ML5652 and 7ML5662) Siemens FI 01 June 2015 /59

60 Point level measurement - RF Capacitance switches Pointek CLS300 Standard and Digital Pressure/temperature curve CLS300 extended rod and cable probes EN flanged process connections (7ML5650, 7ML5651, 7ML5660 and 7ML5661) Permitted operating pressures P 50 bar (725 psi) 0 bar (580 psi) 30 bar (35 psi) 20 bar (290 psi) PN 0 1) Atmospheric -1 bar (-1.5 psi) -150 ºC (-238 ºF) -100 ºC (-18 ºF) 10 bar (15 psi) -0 ºF 1 ºF (-0 ºC) (-10 ºC) -50 ºC (-58 ºF) -29 ºC (-20 ºF) 100 ºF (38 ºC) 200 ºF (93 ºC) 0 ºC RT 50 ºC 100 ºC (32 ºF) (122 ºF) (212 ºF) 300 ºF (19 ºC) 150 ºC (302 ºF) 00 ºF (20 ºC) 200 ºC (392 ºF) 500 ºF (260 ºC) 250 ºC (82 ºF) 600 ºF (315 ºC) 300 ºC (572 ºF) 700 ºF (371 ºC) 350 ºC (662 ºF) 00 ºC (752 ºF) PN 16 1) Permitted operating temperature T 1) The curve denotes the minimum allowable flange class for the shaded area below. Pointek CLS300 Process Pressure/Temperature derating curves (7ML5650, 7ML5651, 7ML5660 and 7ML5661) Pressure/Temperature Curve CLS300 High Temperature Rod Probes EN Flanged Process Connections (7ML5652 and 7ML5662) Permitted Operating Pressures P 50 bar (725 psi) 0 bar (580 psi) 30 bar (35 psi) 20 bar (290 psi) PN 0 1) Atmospheric -1 bar (-1.5 psi) -150 ºC (-238 ºF) -100 ºC (-18 ºF) 10 bar (15 psi) -0 ºF 1 ºF (-0 ºC) (-10 ºC) -50 ºC (-58 ºF) -29 ºC (-20 ºF) 100 ºF (38 ºC) 200 ºF (93 ºC) 0 ºC RT 50 ºC 100 ºC (32 ºF) (122 ºF) (212 ºF) 300 ºF (19 ºC) 150 ºC (302 ºF) 00 ºF (20 ºC) 200 ºC (392 ºF) 500 ºF (260 ºC) 250 ºC (82 ºF) 600 ºF (315 ºC) 300 ºC (572 ºF) 700 ºF (371 ºC) 350 ºC (662 ºF) PN 16 1) 00 ºC (752 ºF) Permitted Operating Temperature T 1) The curve denotes the minimum allowable flange class for the shaded area below. Pointek CLS300 Process Pressure/Temperature derating curves (7ML5652 and 7ML5662) /60 Siemens FI 01 June 2015

61 Point level measurement - RF Capacitance switches Pointek CLS300 Standard and Digital Dimensional drawings Rod version Threaded (7ML5650 and 7ML5660) Lid clip Electronics/ enclosure Lid 20 (0.79) High temperature rod version Threaded (7ML5652 and 7ML5662) 2 cable entries ½" NPT or M20 x 1.5 Y02 1) Thermal isolator M20: 135 (5.32) ½" NPT: 150 (5.91) Probe Measuring length Y01 (insertion length) min. = 250 (9.8)/max. = (39.37) Ceramic isolator(s) Probe Y02 1) Measuring length Y01 (insertion length) min. = 250 (9.8)/max. = (39.37) 165 (6.50) 150 (5.91) Lid with window Lid without window Thermal isolator 275 (10.83) 290 (11.2) Ø19 (0.75) Ø19 (0.75) Cable version, non-insulated Threaded (7ML5651 and 7ML5661) Cable version, insulated Threaded (7ML5651 and 7ML5661) Y02 1) Y02 1) Stainless steel cable Ø6 (0.2) Stainless steel weight 250 (9.8) Measuring length Y01 (insertion length) min. = 500 (20)/max. = (98) PFA insulated cable Ø10 (0.35) Stainless steel weight 250 (9.8) Measuring length Y01 (insertion length) min. = 500 (20)/max. = (98) Ø32 (1.26) Ø32 (1.26) Note: 1) Extended Active Shield (Y02): standard length 125 (.92). Optional active shield lengths: 250 (9.8) or 00 (15.75). Pointek CLS300 - Threaded Process Connections, dimensions in mm (inch) Siemens FI 01 June 2015 /61

62 Point level measurement - RF Capacitance switches Pointek CLS300 Standard and Digital Rod version Welded flange (7ML5650 and 7ML5660) Lid clip Lid High temperature rod version Welded flange (7ML5652 and 7ML5662) Electronics/ enclosure Probe Y02 1) Measuring length Y01 (insertion length) min. = 250 (9.8)/max. = (39.37) Thermal isolator Ceramic isolator(s) Probe Y02 1) Measuring length Y01 (insertion length) min. = 250 (9.8)/max. = (39.37) 185 (7.28) 2 cable entries ½" NPT or M20 x (6.73) Lid with window Lid without window Thermal isolator M20: 135 (5.32) ½" NPT: 150 (5.91) 260 (10.2) 273 (10.75) Ø19 (0.75) Ø19 (0.75) Cable version, non-insulated Welded flange (7ML5651 and 7ML5661) Cable version, insulated Welded flange (7ML5651 and 7ML5661) Flange Facing (raised face) Flange Class Facing thickness ASME 150/300 2 (0.08) ASME 600/900 7 (0.28) PN16/0 2 (0.08) Stainless steel cable Ø6 (0.2) Stainless steel weight 250 (9.8) Y02 1) Measuring length Y01 (insertion length) min. = 500 (20)/max. = (98) PFA insulated cable Ø10 (0.35) Stainless steel weight 250 (9.8) Y02 1) Measuring length Y01 (insertion length) min. = 500 (20)/max. = (98) Ø32 (1.26) Ø32 (1.26) Note: 1) Extended Active Shield (Y02): standard length 105 (.13). Optional active shield lengths: 230 (9.06) or 380 (1.96). Insertion length does not include any raised face/gasket face dimension (see Flange Facing Table above) Pointek CLS300 - Flanged Process Connections, dimensions in mm (inch) /62 Siemens FI 01 June 2015

63 Point level measurement - RF Capacitance switches Pointek CLS300 Standard and Digital Schematics Wiring: Pointek CLS300 standard White Black Red P1 - + Delay Switch bank S1 OFF L2 Output status (+) L1 Sensor status Sensor (f) K1 Trip point GND L3 Power on Power supply 12 to 250 V AC/DC NC NO NO K2 K3 Solid state switch: 30 V DC/30 V AC (peak), 82 ma max. Relay contact: 8 A at 250 V AC, VA 5 A at 30 V DC, 150 W Notes: - Identification label is on underside of lid. Switch and potentiometer settings are for illustration purposes only (refer to operation/setup in manual). - All field wiring must have insulation suitable for at least 250 V. - Relay contact terminals are for use with equipment having no accessible live parts and wiring having insulation suitable for at least 250 V. - Maximum working voltage between adjacent relay contacts shall be 250 V. - Refer to the Instruction manual or contact Siemens representative for detailed wiring information. P2 K Wiring: Pointek CLS300 digital Test input White White Reed contact* Red (+) Alarm output solid-state switch Sensor 2 V DC/PROFIBUS PA Black (-) Orange (f) Power connection: 2 V DC or PROFIBUS PA bus (not polarity sensitive). Notes: Refer to the instruction manual or contact a Siemens representative for detailed wiring information. *Magnet activated sensor test A magnet can be used to test the sensor without opening the lid of the Pointek CLS300 digital version. Bring the magnet close to the test area indicated on the enclosure. The sensor test starts and finishes automatically after 10 seconds. Pointek CLS300 connection Siemens FI 01 June 2015 /63

64 Point level measurement - RF Capacitance switches Pointek CLS500 Overview Configuration Installation Pointek CLS500 is an inverse frequency shift capacitance level and material detection switch ideal for detecting interfaces, solids, liquids, toxic, and aggressive chemicals in critical conditions of high temperature and pressure. CLS500 also has the ability to tune out build-up on the probe. Benefits Active-Shield technology so measurement is unaffected by material buildup in active shield section 2-wire loop powered with solid-state switch or to 20/20 to ma output Simple push-button calibration and integrated local display Full function diagnostics HART communications for remote commissioning and inspection Application Active-Shield technology ensures that measurement is unaffected by vapors, product deposits, dust and condensation. The unique mechanical probe design coupled with a high performance transmitter gives superior performance in a wide range of level detection applications. Pointek CLS500 s microprocessor-based electronics provide one-point calibration, making setup possible without shutting down your production process. Key Applications: foam or liquid/foam level, glycol regenerators, high-pressure coalescers, LNG applications Keep unit out of path of falling material, or protect probe from falling material. Build up of material in active shield area does not affect switch operation. 50 (2) Install probe at least 50 (2) from tank wall. Pointek CLS500 installation, dimensions in mm (inch) /6 Siemens FI 01 June 2015

65 Point level measurement - RF Capacitance switches Pointek CLS500 Technical specifications Input Measuring range Span Output Solid-state switch Output Protection Max. switching voltage Max. load current Voltage drop Time delay (pre or post switching) Current loop Accuracy (transmitter) Temperature stability Non-linearity and repeatability Accuracy Rated operating conditions 1) Installation conditions Location pf Min. 1 pf Galvanically isolated Against reversed polarity (bipolar) 30 V (DC) 30 V peak (AC) 82 ma < 1 V, typical at 50 ma s ma/20... ma 0.15 pf (0 pf) or < 0.25 % (typical < 0.1 %) of actual measurement value, whichever is greater over the full temperature range 0.1 % of full scale and actual measurement respectively Deviation < 0.1 % of measured value Indoor/outdoor Ambient conditions Ambient temperature (transmitter) C ( F) 2) Installation category I Pollution degree Medium conditions Relative dielectric constant ε r Min. 1.5 Process temperature Temperature ratings are pressure dependent. See Pressure/Temperature curves on page /72. - Standard (PFA) C ( F) - High temperature stainless steel C ( F) version with thermal isolator - Cryogenic version C ( F) Contact ceg.smpi@siemens.com for details. Process pressure Pressure rating of process seal is temperature dependent. See Pressure/Temperature curves on page /72. Standard (PFA) bar g ( psi g) High temperature version (Stainless steel) bar g ( psi g) Design Material Wetted parts material - Standard rod 316L stainless steel Probe isolation (rod) PFA Probe diameter Standard rod version (PFA) 16 mm (0.63 inch) High temperature rod version 19 mm (0.75 inch) (Stainless steel) Probe length Standard rod version (PFA) Max mm (39. inch) with 16 mm (0.63 inch) diameter probe High temperature rod version Max. measuring length mm (Stainless steel) (39. inch) with 19 mm (0.75 inch) diameter probe Process connection of probe Threaded mounting Flange mounting ASME, EN Enclosure Material Cable inlet Degree of protection Power supply Features Measurement current signaling NAMUR NE 3 Safety Diagnostics with fault alarm when: Function rotary switch SMART communication NPT [(Taper), ANSI/ASME B1.20.1] R [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] G [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] Aluminum, epoxy-coated (Stainless steel option available. Contact ceg.smpi@siemens.com) 2 x ½" NPT Type X/NEMAX/IP65, IP68 Max. 33 V DC Inputs/outputs fully galvanically isolated Polarity-insensitive current loop Fully potted Integrated safety barrier Primary variable (PV) out of limits, system failure in measurement circuit, deviation between A/D and D/A converter, check sum, watch dog and self-checking facility Positions , A... F Conforming to HART Communication Foundation (HCF) Certificates and approvals General Purpose CE, CSA/FM, RCM Non incendive/non sparking CSA/FM Class I, Div. 2, Groups A, B, C, D T ATEX II 3G 2D EEx n A [ib] IIC T6... T T100 C Dust Ignition Proof CSA/FM Class II and III, Div. 1, Groups E, F, G T ATEX II 1/2 GD EEx d [ia] T6... T1 T100 C Explosion Proof FM Class 1, Div. 1, Groups A, B, C, D T ATEX II 1/2 GD EEx d [ia] IIC T6... T1 T100 C Marine Lloyds Register of Shipping, Categories ENV1, ENV2, ENV3, ENV5, Bureau Veritas 1) When operation is in areas classified as hazardous, observe restrictions according to relevant certificate. See also Pressure/Temperature curves on page /72. 2) Thermal isolator is used if process connection temperature exceeds 85 C (185 F) Siemens FI 01 June 2015 /65

66 Point level measurement - RF Capacitance switches Pointek CLS500 Pointek CLS500 probe version Standard HT Series Process connection types Standard (PFA) (7ML5601, 7ML5602, 7ML5603) High Temperature (Stainless steel) (7ML560) Threaded Available as standard Flange Available as standard Available as standard Process connection materials 316L stainless steel Available as standard Available as standard Probe insulation None HT Stainless: available as standard PFA Available as standard Length parameters Max. rod length mm (0 inch) 1000 mm (0inch) Process condtitions 1) Max. process pressure 150 bar g (2 175 psi g) Stainless steel: 2) 35 bar g (507 psi g) Max. process temperature 200 C (392 F) 00 C (752 F) 1) When operation is in areas classified as hazardous, observe restrictions according to relevant certificate. See also Pressure/Temperature curves on page /72. Pressure rating of process seal is temperature dependent. 2) Pressure rating of process seal is temperature dependent. See Pressure/Temperature curves on page /72. Not available as standard /66 Siemens FI 01 June 2015

67 Point level measurement - RF Capacitance switches Pointek CLS500 Pointek CLS500, threaded Inverse frequency shift capacitance level and material detection switch for detecting interfaces, solids, liquids, toxic and aggressive chemicals in critical conditions of extreme temperature and pressure. CLS500 also has the ability to tune out build-up on the probe. Click on the for the online configuration in the PIA Life Cycle Portal. 7ML A 0 Electronic transmitter No transmitter supplied 0 MSP (330 pf) 1 Process connection ¾" A 1" B 1¼" C 1½" D 2" E Threaded connection and rating NPT [(Taper), ANSI/ASME B1.20.1] A R [(BSPT), EN 10226/PT (JIS-T) JIS B 0203] B G [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] D Probe insulation/material of process connection PFA insulation/316l stainless steel 1 Approvals General Purpose: CE, CSA/FM, RCM 1 CSA/FM Class I, Div. 2, Groups A, B, C, D T; 2 ATEX II 3GD 2D EEx na [ib] IIC T6 to T T100 C; CSA/FM Class II and III Div. 1, Groups E, F, G T ATEX II 1/2 GD EEx d [ia] IIC T6 to T1 T100 C FM Class I, Div. 1, Groups A, B, C, D T 6 Probe/electrode diameter 16 mm (0.63 inch) rigid rod, minimum insertion length 200 mm (7.9 inch), maximum insertion length mm (39. inch) 1) Thermal isolator/remote version Rigid thermal isolator [for process connection temperature over 85 C (185 F)] No thermal isolator 1) Add Order code Y01 and Y02 in plain text: "Insertion/active shield length to mm" 1 A B Order code Further designs Please add "-Z" to and specify Order code(s). Total insertion length: enter the total insertion length Y01 in plain text description Note: The difference between Y01 and Y02 must be a minimum of 150 mm Active Shield length - minimum length is 50 mm Y02 Y02: to mm 1) Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Y15 Measuring-point number/identification (max. 27 characters) specify in plain text Manufacturer's test certificate: M to DIN 55350, C11 Part 18 and to ISO 9000 Inspection Certificate Type 3.1 per EN 1020 C12 Operating Instructions Note: The Operating Instructions should be See page /71 ordered as a separate line on the order. This device is shipped with the Siemens Milltronics manual DVD containing the ATEX Quick Start and manual library. Pointek Specials See page /80 1) See dimension drawings on page /77 for further explanation of Y02 Siemens FI 01 June 2015 /67

68 Point level measurement - RF Capacitance switches Pointek CLS500 Pointek CLS500, welded flange 7ML5602- Inverse frequency shift capacitance level and material detection switch for detecting interfaces, - 77A 0 solids, liquids, toxic and aggressive chemicals in critical conditions of extreme temperature and pressure. CLS500 also has the ability to tune out build-up on the probe. Click on the for the online configuration in the PIA Life Cycle Portal. Electronic transmitter MSP (330 pf) 1 Process connection and pressure rating Welded flange, 316L stainless steel, raised face 2" ASME, 150 lb A A 2" ASME, 300 lb A B 3" ASME, 150 lb B A 3" ASME, 300 lb 1) B B " ASME, 150 lb 1) C A " ASME, 300 lb 1) C B 6" ASME, 150 lb 1) D A 6" ASME, 300 lb 1) D B Welded flange, 316L stainless steel, Type A flat faced DN 50 PN 16 E C DN 50 PN 0 E D DN 80 PN 16 F C DN 80 PN 0 F D DN 100 PN 16 1) G C DN 125 PN 16 1) H C (Note: Flange bolting patterns and facings dimensionally correspond to the applicable ASME B16.5 or EN standard.) Probe insulation/material of process connection PFA insulation/316l stainless steel 1 Approvals General Purpose 1 CSA/FM Class I, Div. 2, Groups A, B, C, D T; 2 ATEX II 3GD 2D EEx na [ib] IIC T6 to T T100 C; CSA/FM Class II and III Div. 1, Groups E, F, G T ATEX II 1/2 GD EEx d [ia] IIC T6 to T1 T100 C FM Class I, Div. 1, Groups A, B, C, D T 6 Probe/electrode diameter 16 mm (0.63 inch) rigid rod, min. length 200 mm 1 (7.9 inch), max. length mm (39. inch) Thermal isolator Rigid thermal isolator A [for process temperature over 85 C (185 F)] No thermal isolator B 1) Custom shipping methods required. Contact factory for more details. Order code Further designs Please add "-Z" to and specify Order code(s). Total insertion length: enter the total insertion length Y01 in plain text description Active Shield length - minimum length is 50 mm. Y02 Y02: to mm 1) Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Y15 Measuring-point number/identification (max. 27 characters) specify in plain text Manufacturer's test certificate: M to DIN 55350, C11 Part 18 and to ISO 9000 Inspection Certificate Type 3.1 per EN 1020 C12 Operating Instructions Note: The Operating Instructions should be See page /71 ordered as a separate line on the order. This device is shipped with the Siemens Milltronics manual DVD containing the ATEX Quick Start and manual library. Pointek Specials See page /80 1) See dimensional drawings on page /77 for further explanation of Y02 /68 Siemens FI 01 June 2015

69 Point level measurement - RF Capacitance switches Pointek CLS500 Pointek CLS500, single piece flange Inverse frequency shift capacitance level and material detection switch for detecting interfaces, solids, liquids, toxic and aggressive chemicals in critical conditions of extreme temperature and pressure. CLS500 also has the ability to tune out build-up on the probe. Click on the for the online configuration in the PIA Life Cycle Portal. 7ML A 0 Electronic transmitter MSP (330 pf) 1 Process connection and pressure rating Single piece flange, 316L stainless steel, raised face 2" ASME, 150 lb A A 2" ASME, 300 lb A B 3" ASME, 150 lb B A 3" ASME, 300 lb 1) B B " ASME, 150 lb 1) C A " ASME, 300 lb 1) C B 6" ASME, 150 lb 1) D A 6" ASME, 300 lb 1) D B Single piece flange, 316L stainless steel, Type B1 raised faced DN 50 PN 16 E C DN 50 PN 25 E D DN 80 PN 16 F C DN 80 PN 25 F D DN 100 PN 16 1) G C DN 100 PN 25 1) G D DN 125 PN 16 1) H C DN 125 PN 25 1) HD Probe insulation/material of process connection PFA insulation/316l stainless steel 1 Approvals General Purpose: CE, CSA/FM, RCM 1 CSA/FM Class I, Div. 2, Groups A, B, C, D T; 2 ATEX II 3GD 2D EEx na [ib] IIC T6 to T T100 C; CSA/FM Class II and III Div. 1, Groups E, F, G T ATEX II 1/2 GD EEx d [ia] IIC T6 to T1 T100 C FM Class I, Div. 1, Groups A, B, C, D T 6 Probe/electrode diameter 16 mm (0.63 inch) rigid rod, maximum length mm (39. inch) (Y01) Thermal isolator Rigid thermal isolator [for process connection temperature over 85 C (185 F)] No thermal isolator 1) Custom shipping methods required. Contact factory for more details 1 A B Order code Further designs Please add "-Z" to and specify Order code(s). Total insertion length: enter the total insertion length Y01 in plain text description Active Shield length - minimum length is 50 mm. Y02 Y02: to mm 1) Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Y15 Measuring-point number/identification (max. 27 characters) specify in plain text Manufacturer's test certificate: M to DIN 55350, C11 Part 18 and to ISO 9000 Inspection Certificate Type 3.1 per EN 1020 C12 Operating Instructions Note: The Operating Instructions should be See page /71 ordered as a separate line on the order. This device is shipped with the Siemens Milltronics manual DVD containing the ATEX Quick Start and manual library. Accessories See page /80 1) See dimensional drawings on page /77 for further explanation of Y02 Siemens FI 01 June 2015 /69

70 Point level measurement - RF Capacitance switches Pointek CLS500 Pointek CLS500 High temperature Inverse frequency shift capacitance level and material detection switch for detecting interfaces, 7ML560-7 A solids, liquids, toxic and aggressive chemicals in critical conditions of extreme temperature and pressure. CLS500 also has the ability to tune out build-up on the probe. Click on the for the online configuration in the PIA Life Cycle Portal. Electronic transmitter MSP (330 pf) 1 Process connection and pressure rating 316L stainless steel, raised face 1) 2" ASME, 150 lb A1 2" ASME, 300 lb A2 2" ASME, 600 lb A3 2" ASME, 900 lb A 3" ASME, 150 lb B1 3" ASME, 300 lb 2) B2 3" ASME, 600 lb 2) B3 3" ASME, 900 lb 2) B " ASME, 150 lb 2) C1 " ASME, 300 lb 2) C2 " ASME, 600 lb 2) C3 " ASME, 900 lb 2) C 6" ASME, 150 lb 2) D1 6" ASME, 300 lb 2) D2 6" ASME, 600 lb 2) D3 6" ASME, 900 lb 2) D 316L stainless steel, Type B1 flat faced DN 50 PN 16 E1 DN 50 PN 25 E2 DN 50 PN 0 E3 DN 50 PN 63 E DN 80 PN 16 F1 DN 80 PN 25 F2 DN 80 PN 0 2) F3 DN 80 PN 63 2) F DN 100 PN 16 2) G1 DN 100 PN 25 2) G2 DN 100 PN 0 2) G3 DN 100 PN 6 2) G DN 125 PN 16 2) H1 DN 125 PN 25 2) H2 DN 125 PN 0 2) H3 DN 125 PN 6 2) H (Note: Flange bolting patterns and facings dimensionally correspond to the applicable ASME B16.5 or EN standard.) Pointek CLS500 High temperature 7ML560- Inverse frequency shift capacitance level and 7 A material detection switch for detecting interfaces, solids, liquids, toxic and aggressive chemicals in critical conditions of extreme temperature and pressure. CLS500 also has the ability to tune out build-up on the probe. Probe material of process connection No insulation/316l stainless steel 3)) 1 Stilling well No stilling well 0 Approvals General Purpose A CSA/FM Class I, Div. 2, Groups A, B, C, D T; B ATEX II 3GD 2D EEx na [ib] IIC T6 to T T100 C; CSA/FM Class II and III Div. 1, Groups E, F, G T ATEX II 1/2 GD EEx d [ia] IIC T6 to T1 T100 C D FM Class I, Div. 1, Groups A, B, C, D T F Probe/electrode diameter Maximum length mm (39.37 inch) ) A Thermal isolator Rigid thermal isolator [for process connection 1 temperature over 85 C (185 F)] 1) Welded flange for no insulation option only 2) Custom shipping methods required 3) Non-conductive material only, stainless steel non-insulated probe diameter 19 mm (0.75 inch) ) Add Order code Y01 and Y02 in plain text: "Insertion/active shield length to mm" Minimum insertion length depends on probe version selected. See dimensional drawings on page /77 for more details. /70 Siemens FI 01 June 2015

71 Point level measurement - RF Capacitance switches Pointek CLS500 Further designs Please add "-Z" to and specify Order code(s). Order code Total insertion length: enter the total insertion length Y01 in plain text description Active Shield length - minimum length is 50 mm. Y02 Y02: to mm 1) Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Y15 Measuring-point number/identification (max. 27 characters) specify in plain text Manufacturer's test certificate: M to DIN 55350, C11 Part 18 and to ISO 9000 Inspection Certificate Type 3.1 per EN 1020 C12 Operating Instructions English 7ML1998-5GG03 German 7ML1998-5GG32 French 7ML1998-5GG11 Dutch 7ML1998-5GG1 Note: The Operating Instructions should be ordered as a separate line on the order. This device is shipped with the Siemens Milltronics manual DVD containing the ATEX Quick Start and Operating Instructions library. Quick Start manual, multi-language A5E This device is shipped with the Siemens Milltronics manual DVD containing the ATEX Quick Start and Operating Instructions library. Accessories General Purpose 1/2" NPT General Purpose Cable Entry IP68/IP69K 7ML1830-1JA NEMA6, C ( F), cable size mm ( inch) M20x1.5 General Purpose Cable Entry IP68/IP69K 7ML1830-1JC NEMA6, C ( F), cable size mm ( inch) Transmitter, MSP , 330 PF 7ML1830-1JP Hazardous Locations 1/2" NPT EMC rated Cable Gland: Dust Ignition Proof, 7ML1830-1JB Flameproof Exd, and Increased Safety ATEX II 2 GD ExtD A21 (Zone 1, Zone 2, Zone 21, Zone 22, and in Gas Groups IIA,IIB and IIC) C IP66, IP67, IP68, NEMAX, cable sizes mm ( inch) M20 EMC rated Cable Gland: Dust Ignition Proof, 7ML1830-1JD Flameproof Exd, and Increased Safety ATEX II 2 GD ExtD A21 (Zone 1, Zone 2, Zone 21, Zone 22 and in Gas Groups IIA,IIB and IIC) C IP66, IP67, IP68, NEMAX, cable sizes mm ( inch) Pointek Specials See page /80 1) See dimensional drawings on page /77 for further explanation of Y02 Siemens FI 01 June 2015 /71

72 Point level measurement - RF Capacitance switches Pointek CLS500 Characteristic curves Pressure/temperature curve CLS500 rod probes Threaded process connections (7ML5601) Permitted operating pressures P 150 bar (2.175 psi) 10 bar (2.030 psi) 130 bar (1.885 psi) 120 bar (1.70 psi) 110 bar (1.595 psi) 100 bar (1.50 psi) 90 bar (1.305 psi) 80 bar (1.160 psi) 70 bar (1.015 psi) 60 bar (870 psi) 50 bar (725 psi) 0 bar (580 psi) 30 bar (35 psi) 20 bar (290 psi) Atmospheric -1 bar (-1.5 psi) -150 ºC (-238 ºF) -100 ºC (-18 ºF) 10 bar (15 psi) -0 ºF 1 ºF (-0 ºC) (-10 ºC) -50 ºC (-58 ºF) -29 ºC (-20 ºF) 100 ºF (38 ºC) 200 ºF (93 ºC) 0 ºC RT 50 ºC 100 ºC (32 ºF) (122 ºF) (212 ºF) 300 ºF (19 ºC) 150 ºC (302 ºF) 00 ºF (20 ºC) 200 ºC (392 ºF) 500 ºF (260 ºC) 250 ºC (82 ºF) 600 ºF (315 ºC) 300 ºC (572 ºF) 700 ºF (371 ºC) 350 ºC (662 ºF) 00 ºC (752 ºF) Permitted operating temperature T Example: Permitted operating pressure = 137 bar (1988 psi) at 75 C Pointek CLS500 Process Pressure/Temperature derating curves (7ML5601) /72 Siemens FI 01 June 2015

73 Point level measurement - RF Capacitance switches Pointek CLS500 Pressure/temperature curve CLS500 rod probes ASME flanged process connections (7ML5602 and 7ML5603) Permitted operating pressures P 150 bar (2.175 psi) 10 bar (2.030 psi) 130 bar (1.885 psi) 120 bar (1.70 psi) 110 bar (1.595 psi) 100 bar (1.50 psi) 90 bar (1.305 psi) 80 bar (1.160 psi) 70 bar (1.015 psi) 60 bar (870 psi) 50 bar (725 psi) 0 bar (580 psi) 30 bar (35 psi) ASME 300 lb 1) 20 bar (290 psi) Atmospheric -1 bar (-1.5 psi) -150 ºC (-238 ºF) -100 ºC (-18 ºF) 10 bar (15 psi) -0 ºF 1 ºF (-0 ºC) (-10 ºC) -50 ºC (-58 ºF) -29 ºC (-20 ºF) 100 ºF (38 ºC) 200 ºF (93 ºC) 0 ºC RT 50 ºC 100 ºC (32 ºF) (122 ºF) (212 ºF) 300 ºF (19 ºC) 150 ºC (302 ºF) 00 ºF (20 ºC) 200 ºC (392 ºF) 500 ºF (260 ºC) 250 ºC (82 ºF) 600 ºF (315 ºC) 300 ºC (572 ºF) 700 ºF (371 ºC) 350 ºC (662 ºF) ASME 150 lb 1) 00 ºC (752 ºF) Permitted operating temperature T 1) The curve denotes the minimum allowable flange class for the shaded area below. Pointek CLS500 Process Pressure/Temperature derating curves (7ML5602 and 7ML5603) Siemens FI 01 June 2015 /73

74 Point level measurement - RF Capacitance switches Pointek CLS500 Pressure/temperature curve CLS500 rod probes EN flanged process connections (7ML5602 and 7ML5603) Permitted operating pressures P 150 bar (2.175 psi) 10 bar (2.030 psi) 130 bar (1.885 psi) 120 bar (1.70 psi) 110 bar (1.595 psi) 100 bar (1.50 psi) 90 bar (1.305 psi) 80 bar (1.160 psi) 70 bar (1.015 psi) 60 bar (870 psi) 50 bar (725 psi) 0 bar (580 psi) 30 bar (35 psi) Atmospheric -1 bar (-1.5 psi) -150 ºC (-238 ºF) -100 ºC (-18 ºF) 20 bar (290 psi) 10 bar (15 psi) -0 ºF 1 ºF (-0 ºC) (-10 ºC) -50 ºC (-58 ºF) -29 ºC (-20 ºF) 100 ºF (38 ºC) 200 ºF (93 ºC) 0 ºC RT 50 ºC 100 ºC (32 ºF) (122 ºF) (212 ºF) 300 ºF (19 ºC) 150 ºC (302 ºF) 00 ºF (20 ºC) 200 ºC (392 ºF) 500 ºF (260 ºC) 250 ºC (82 ºF) 600 ºF (315 ºC) 300 ºC (572 ºF) 700 ºF (371 ºC) 350 ºC (662 ºF) 00 ºC (752 ºF) PN 25 1) PN 16 1) Permitted operating temperature T 1) The curve denotes the minimum allowable flange class for the shaded area below. Pointek CLS500 Process Pressure/Temperature derating curves (7ML5602 and 7ML5603) /7 Siemens FI 01 June 2015

75 Point level measurement - RF Capacitance switches Pointek CLS500 Pressure/temperature curve CLS500 high temperature (no insulation) ASME flanged process connections (7ML560) Permitted operating pressures P 90 bar (1.305 psi) 80 bar (1.160 psi) 70 bar (1.015 psi) 60 bar (870 psi) 50 bar (725 psi) ASME 600 lb 1) 0 bar (580 psi) 30 bar (35 psi) ASME 300 lb 1) 20 bar (290 psi) Atmospheric -1 bar (-1.5 psi) -150 ºC (-238 ºF) -100 ºC (-18 ºF) 10 bar (15 psi) -0 ºF 1 ºF (-0 ºC) (-10 ºC) -50 ºC (-58 ºF) -29 ºC (-20 ºF) 100 ºF (38 ºC) 200 ºF (93 ºC) 0 ºC RT 50 ºC 100 ºC (32 ºF) (122 ºF) (212 ºF) 300 ºF (19 ºC) 150 ºC (302 ºF) 00 ºF (20 ºC) 200 ºC (392 ºF) 500 ºF (260 ºC) 250 ºC (82 ºF) 600 ºF (315 ºC) 300 ºC (572 ºF) 700 ºF (371 ºC) 350 ºC (662 ºF) ASME 150 lb 1) 00 ºC (752 ºF) Permitted operating temperature T 1) The curve denotes the minimum allowable flange class for the shaded area below. Pointek CLS500 Process Pressure/Temperature derating curves (7ML560) Siemens FI 01 June 2015 /75

76 Point level measurement - RF Capacitance switches Pointek CLS500 Pressure/temperature curve CLS500 high temperature (no insulation) EN flanged process connections (7ML560) Permitted operating pressures P 0 bar (580 psi) 30 bar (35 psi) 20 bar (290 psi) PN 0 1) Atmospheric -1 bar (-1.5 psi) -150 ºC (-238 ºF) -100 ºC (-18 ºF) 10 bar (15 psi) -0 ºF 1 ºF (-0 ºC) (-10 ºC) -50 ºC (-58 ºF) 100 ºF (38 ºC) 200 ºF (93 ºC) 0 ºC RT 50 ºC 100 ºC (32 ºF) (122 ºF) (212 ºF) 300 ºF (19 ºC) 150 ºC (302 ºF) 00 ºF (20 ºC) 200 ºC (392 ºF) 500 ºF (260 ºC) 250 ºC (82 ºF) 600 ºF (315 ºC) 300 ºC (572 ºF) 700 ºF (371 ºC) 350 ºC (662 ºF) 00 ºC (752 ºF) PN 25 1) PN 16 1) -29 ºC (-20 ºF) Permitted operating temperature T 1) The curve denotes the minimum allowable flange class for the shaded area below. Pointek CLS500 Process Pressure/Temperature derating curves (7ML560) /76 Siemens FI 01 June 2015

77 Point level measurement - RF Capacitance switches Pointek CLS500 Dimensional drawings Standard rod version Threaded (7ML5601) Standard configuration (7ML5601) PFA insulated probe 30 (1.18) Transmitter/ electronics 20 (0.79) 1/2" NPT: 230 (9.1) Measuring length Y02 Y01 (insertion length) min. = 200 (7.87) / max. = (39.37) 270 (10.6) 205 (8.1) With explosion-proof seal option (all versions) Thermal isolator With thermal isolator option (all versions) 30 (16.9) Inactive tip Ø16 (0.63) Pointek CLS500 - Threaded Process Connections, dimensions in mm (inch) Siemens FI 01 June 2015 /77

78 Point level measurement - RF Capacitance switches Pointek CLS500 Standard Rod version Welded Flange (7ML5602) Single Piece Flange (7ML5603) Standard configuration (7ML5602, 7ML5603) PFA insulated probe 30 (1.18) Transmitter/ electronics Measuring length 1) Y02 1) Y01 (insertion length) min. = 200 (7.87)/max. = (39.37) 270 ( (8.1) With explosion-proof seal option (all versions) Thermal isolator ½" NPT: 230 (9.1) With thermal isolator option (all versions) 30 (16.9) Inactive tip Ø16 (0.63) High temperature rod version Welded Flange (7ML560), Stainless steel rod ) Thermal isolator Flange Facing (raised face) Flange Class Facing thickness ASME 150/300 2 (0.08) ASME 600/900 7 (0.28) PN16/25/0/6 2 (0.08) Notes: 1) Min. Y02 (active shield length) = 50 (1.96) 2) Min. Y02 (active shield length) = 105 (.13) 3) Min. Y02 (active shield length) = 100 (3.9) ) Non conductive materials only Stainless steel probe Y02 2) Measuring length 2) Y01 (insertion length) min. = 200 (7.87)/max. = (39.37) Insertion length does not include any raised face/gasket face dimension (see Flange Facing Table above) Ø19 (0.75) Pointek CLS500 - Flanged Process Connections, dimensions in mm (inch) /78 Siemens FI 01 June 2015

79 Tampering voids warranty Siemens AG 2015 Point level measurement - RF Capacitance switches Pointek CLS500 Schematics Ground lug Protective label Instrument system ground Measuring signal (minicoaxial cable) Type: Ser.: Date: Rev.: Solid state switch relay (any polarity) ma current loop connection (any polarity) Ground connection point for instrument system Pointek CLS500 connections Siemens FI 01 June 2015 /79

80 Point level measurement - RF Capacitance switches Pointek CLS Specials Selection and ordering data Pointek Specials 1) Pointek Specials 1) CLS100 Polycarbonate Lid and Gasket, FKM Kit, Sensor for cable units, PPS, Digital, FKM A5E Kit, Sensor for cable units, PPS, Standard, FFKM A5E Kit, Sensor for cable units, PPS, Digital, FFKM A5E Kit, Lid and gasket, CLS100 enclosure version CLS100 Miscellaneous Parts A5E Kit, Sensor for cable units, PVDF, Standard, FKM Kit, Sensor for cable units, PVDF, Digital, FKM A5E A5E Custom length of cable is available only for 7ML5501-xxx1x and 7ML5501-xxx5x 2) CLS200 Gasket (IP65), Synprene Kit, Sensor for cable units, PVDF, Standard, FFKM Kit, Sensor for cable units, PVDF, Digital, FFKM A5E A5E CLS200 Mounting Bracket, 316L stainless steel Spare gasket, enclosure version (IP65 versions only) A5E CLS200 Gasket (IP68), Silicone Spare mounting bracket A5E CLS200 PROFIBUS Connector (IP65) Spare gasket, enclosure version (IP68 versions) A5E CLS200 Blind Lid Spare, PROFIBUS connector (IP65 versions only) A5E CLS200 Miscellaneous Parts CLS200 with FFKM O-rings (any version) 2) CLS200 Electronics Test magnet, digital version 7ML1830-1JE Spare aluminum blind lid (for standard versions only) CLS200 Lid with window A5E Amplifier/power supply kit, standard version Amplifier/power supply, digital version LCD display, digital version A5E ML1830-1JF 7ML1830-1JK CLS300 Cable Extensions, 316L stainless steel Spare aluminum lid with window CLS200 Sensor Kit for cable units A5E Kit, stainless steel cable extension, 1 m, adjustable by customer A5E Kit, stainless steel cable extension, 3 m, adjustable by customer A5E Kit, stainless steel cable extension, 5 m, adjustable by customer A5E Kit, Sensor for cable units, PPS, Standard, FKM A5E Kit, stainless steel cable extension, 10 m, adjustable by customer A5E Kit, stainless steel cable extension, 15 m, adjustable by customer A5E Kit, stainless steel cable extension, 20 m, adjustable by customer A5E /80 Siemens FI 01 June 2015

81 Point level measurement - RF Capacitance switches Pointek CLS Specials Pointek Specials 1) Pointek Specials 1) CLS300 Cable Extensions, 316 stainless steel with PFA coating CLS300 Electronics Kits with drivers (for rod or cable versions) Kit, Electronics with driver, standard CLS300. To be used in rod or cable versions with length less than 5 m. 3)) A5E Kit, PFA cable extension, 1 m, adjustable by customer Kit, PFA cable extension, 3 m, adjustable by customer Kit, PFA cable extension, 5 m, adjustable by customer Kit, PFA cable extension, 10 m, adjustable by customer Kit, PFA cable extension, 15 m, adjustable by customer Kit, PFA cable extension, 20 m, adjustable by customer CLS300 Rod Kits, 316L stainless steel A5E A5E A5E A5E A5E A5E Kit, Electronics with driver, digital CLS300. To be used in rod or cable versions with length less than 5 m. 3)) CLS300 Electronics Kits with drivers (for cable versions) Kit, Electronics with driver, standard CLS300. To be used in cable versions with length greater than 5 m. 3)) Kit, Electronics with driver, digital CLS300. To be used in cable versions with length greater than 5 m. 3)) CLS300 Electronics A5E A5E A5E Test magnet, digital version 7ML1830-1JE Amplifier/power supply kit, standard version A5E Amplifier/power supply, digital version 7ML1830-1JF Kit, stainless steel rod 180 mm (7.09 inch) to be used with CLS300 units only (with standard active shield). Insertion length after installation is 350 mm (13.78 inch). A5E LCD display, digital version CLS300 Weight Kit, 316L stainless steel 7ML1830-1JK Kit, stainless steel rod 330 mm (12.99 inch) to be used with CLS300 units only (with standard active shield). Insertion length after installation is 500 mm (19.69 inch). A5E Kit, stainless steel rod 580 mm (22.83 inch) to be used with CLS300 units only (with standard active shield). Insertion length after installation is 750 mm (29.53 inch). Kit, stainless steel rod 830 mm (32.68 inch) to be used with CLS300 units only (with standard active shield). Insertion length after installation is mm (39.37 inch). A5E A5E Kit, Spare stainless steel weight. To be used in any cable version of CLS300 CLS500 Gasket (IP65), Silicone A5E Kit, stainless steel rod mm (52.36 inch) to be used with CLS300 units only (with standard active shield). Insertion length after installation is mm (59.06 inch). 2) Spare gasket, CLS500 enclosure version, IP65 CLS500 Blind Lid A5E Kit, stainless steel rod mm (72.05 inch) to be used with CLS300 units only (with standard active shield). Insertion length after installation is mm (78.7 inch). 2) Kit, stainless steel rod customized length up to 1 m 2) Kit, stainless steel rod customized length up to 2 m 2) Spare CLS500 aluminum blind lid CLS500 Electronics Kit Transmitter, MSP , 330 PF A5E ML1830-1JP 1) Special flange sizes and facings are available. Please contact ceg.smpi@siemens.com for part number and pricing. Submit Application Questionnaire found on page /11. 2) Please contact ceg.smpi@siemens.com for part number and pricing. 3) For General Purpose approvals only. ) To maintain approvals, qualified trained Siemens personnel required for part replacement. Please contact ceg.smpi@siemens.com for special requests. Siemens FI 01 June 2015 /81

82 Point level measurement - Vibrating switches SITRANS LVL100 Overview Configuration Horizontal mounting Switching point Switching point (recommended mounting position, particularly for adhesive applications) Vertical mounting SITRANS LVL100 is a compact vibrating level switch for material detection in liquid and slurry applications such as overflow, high, low and demand applications, as well as pump protection. It is ideal for use in confined spaces. Switching point [approx. 13 (0.51)] Switching point with lower density 13 (0.51) 13 (0.51) Benefits Proven vibrating level switch technology for liquids Compact insertion length of 0 mm (1.57 inch) for confined space applications Fault monitoring for corrosion, loss of vibration, or line break to the piezo drive Integrated test function to confirm correct operation Switching point with higher density Application SITRANS LVL100 is a compact level switch designed for industrial use in all areas of process technology and can be used for material detection with liquids and slurries. With an insertion length of only 0 mm (1.57 inch), SITRANS LVL100 can be mounted in small pipes and confined space applications. It is virtually unaffected by the chemical and physical properties of the liquid. The LVL100 can be used in difficult conditions including turbulence, air bubbles, foam generation, buildup, or external vibration. The tuning fork is piezoelectrically energized and vibrates at a mechanical resonance frequency of approximately Hz. The vibration frequency changes when the tuning fork is covered by the medium. This change is detected by the integrated oscillator and converted into a switching command. The integrated electronics evaluate the level signal and output a switching signal to connected devices. Key Applications: For use in liquids and slurries, for level measurement, overfill, and dry run protection Horizontal mounting in viscous or adhesive applications Moisture protection 30 (1.18) NOTE: Welded socket for flush mount optional. Ensure cable gland faces downward to avoid water ingress. SITRANS LVL100 Installation, dimensions in mm (inch) /82 Siemens FI 01 June 2015

83 Point level measurement - Vibrating switches SITRANS LVL100 Technical specifications Mode of operation Measuring principle Input Measured variable Output Output options Measuring Accuracy Hysteresis Vibrating point level switch High and low and demand Contactless electronic switch Transistor output PNP Approx. 2 mm (0.08 inch) with vertical installation Approx. 500 ms (on/off) Approx Hz Switching delay Frequency Rated operating conditions Installation conditions Location Indoor/outdoor Ambient conditions Ambient temperature C ( F) Installation category III Pollution degree 2 Medium conditions Temperature - Standard C ( F) - High temperature option C ( F) Pressure (vessel) bar g ( psi g) Density g/cm³ ( lb/in³) Design Material Enclosure 316L and Plastic PEI Tuning fork 316L (1.0 or 1.35) Process connection (threaded) 316L (1.0 or 1.35) Process seal Klingersil C-00 Process connection Pipe thread, cylindrical G ½" A, G ¾" A or G 1" A (ISO 228 T1) Pipe thread, tapered ½" NPT, ¾" NPT or 1" NPT Hygienic fittings Bolting DN 0 PN 0 Tri-clamp 1", 1½", 2" PN 10 Degree of protection IP65/Type /NEMA (with DIN 3650 valve plug), IP66/67 or IP68 (with M12 connector) Conduit entry 1 x M12 [IP66/IP67 or IP68 (0.2 bar)] Weight (housing) 250 g (9 oz) Power supply Supply voltage V AC, 50/60 Hz V DC Power consumption Max. 0.5 W Certificates and approvals Overfill protection (WHG) Shipping approvals Options LVL100 threaded welded socket G¾" A/316L 32 (1.26) 32 (1.26) G¾" 53 (2.09) 29.5 (1.16) G1" A/316L 39 (1.5) G1" 60 (2.36) SITRANS LVL100 welded socket, dimensions in mm (inch) Siemens FI 01 June 2015 /83

84 Point level measurement - Vibrating switches SITRANS LVL100 SITRANS LVL100 Compact vibrating level switch for use in liquid and slurry applications such as overflow, high, low, and 7ML A 0 demand applications, as well as pump protection. Ideal for use in confined spaces. Click on the for the online configuration in the PIA Life Cycle Portal. Approvals Without approvals 1 Shipping approvals 5) 2 Overfill protection (WHG) 1) 3 Process temperature Standard C ( F) 2) A Extended C ( F) 2) B Hygienic applications C C ( F) 3) Process connection Thread G¾" A PN 6/316L A 0 Thread G¾" A PN 6/316L Ra < 0.8 µm A 1 Thread ¾" NPT PN 6/316L A 2 Thread ¾" NPT PN 6/316L Ra < 0.8 µm A 3 Thread G1" A PN 6/316L A Thread G1" A PN 6/316L Ra < 0.8 µm A 5 Thread 1" NPT PN 6/316L A 6 Thread 1" NPT PN 6/316L Ra < 0.8 µm A 7 Tri-Clamp 1" PN 16 DIN 32676/316L Ra < 0.8 µm A 8 Tri-Clamp 1½" PN 16 DIN 32676/316L Ra < 0.8 µm B 0 Tri-Clamp 2 " PN 16 DIN 32676/316L Ra < 0.8 µm B 1 Bolting DN25 PN 0 DIN 11851/316L Ra < 0.8 µm B 2 Bolting DN0 PN 0 DIN 11851/316L Ra < 0.8 µm B 3 Bolting DN50 PN 25 DIN 11851/316L Ra < 0.8 µm B SMS DN38 PN 6 316L Ra < 0.8 µm B 5 Hygienic fitting with compression nut F0 B 6 PN 25/316L Ra < 0.8 µm Thread G½" (DIN 3852-A) PN6 / 316L C 0 Thread G½" (DIN 3852-A) PN6 / 316L Ra < 0.8 µm C 1 Thread ½" NPT (ASME B1.20.1) PN 6/316L C 2 Thread ½" NPT (ASME B1.20.1) PN 6/316L C 3 Ra < 0.8 µm Electronics Contactless electronic switch V AC/DC ) 1 Transistor output PNP V DC 2 Housing 316L 1 Electrical connection/protection M12x1/IP67 A According to DIN 3650 including plug/ip65 B Acc. to DIN 3650 incl. plug with QuickOn C connection/ip65 M12x1 incl. 5 m cable/ip68 (0.2 bar) D 1) Available with process connection A0, A2, A, and A6 only 2) Available with process connection A1, A3, A5, and A7... B6 only 3) Available with Electrical connection/protection option B and C only ) Available with Process Temperature option A only 5) Available with Process Temperature option A only Order code Further designs Please add "-Z" to and specify Order code(s). Cleaning including certificate W01 (oil, grease and silicone free) Identification Label, foil laser marking Y16 Acceptance test certificate 3.1 for instrument C12 Acceptance test Certificate 2.2 for material C15 EN Inspection Certificate for instrument with test C25 data (EN 1020) Additional Operating Instructions LVL100 (Contactless electronic switch) English 7ML1998-5KN01 French 7ML1998-5KN11 Spanish 7ML1998-5KN21 German 7ML1998-5KN31 LVL100 (Transistor PNP) English 7ML1998-5KP01 French 7ML1998-5KP11 Spanish 7ML1998-5KP21 German 7ML1998-5KP31 This device is shipped with the Siemens Milltronics manual DVD containing the Operating Instructions library. Spare Parts LVL100 Threaded Welded Socket G¾" A/316L with FKM Seal 7ML1930-1EE G1" A/316L with FKM Seal 7ML1930-1EF M27x1.5/316L with FKM Seal 7ML1930-1EG G¾" A/316L with EPDM Seal 7ML1930-1EH G1" A/316L with EPDM Seal 7ML1930-1EJ M27x1.5/316L with EPDM Seal 7ML1930-1EK We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 9/5 in the appendix. We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 9/5 in the appendix. /8 Siemens FI 01 June 2015

85 Point level measurement - Vibrating switches SITRANS LVL100 Characteristic curves Ambient temperature to process temperature dependency (standard version) Ambient temperature in C ( F) 70 ºC (158 ºF) 50 ºC (122 ºF) 0 ºC (32 ºF) -0 ºC (-0 ºF) -0 ºC (-0 ºF) -20 ºC (- ºF) 0 ºC (32 ºF) 20 ºC (68 ºF) 0 ºC (10 ºF) 60 ºC (10 ºF) 80 ºC (176 ºF) Process temperature in C ( F) 100 ºC (212 ºF) Ambient temperature to process temperature dependency (high temperature version) Ambient temperature in C ( F) 70 ºC (158 ºF) 0 ºC (32 ºF) -0 ºC (-0 ºF) -0 ºC (-0 ºF) -20 ºC (- ºF) 0 ºC (32 ºF) 20 ºC (68 ºF) 0 ºC (10 ºF) 60 ºC (10 ºF) 80 ºC (176 ºF) 100 ºC (212 ºF) 120 ºC (28 ºF) 10 ºC (28 ºF) Process temperature in C ( F) 150 ºC (302 ºF) SITRANS LVL100 Ambient Temperature/Process Temperature derating curves Siemens FI 01 June 2015 /85

86 158 (6.22) 158 (6.22) 156 (6.1) 130 (5.1) Siemens AG 2015 Point level measurement - Vibrating switches SITRANS LVL100 Dimensional drawings SITRANS LVL100 (standard) Thread G ¾, G 1 A (DIN ISO 228/1), ¾ NPT or 1 NPT (valve plug ISO 00) 36 (1.2) 27 (1.06) Thread G ½ A (DIN ISO 228/1), ½ NPT (valve plug ISO 00) 36 (1.2) 27 (1.06) SITRANS LVL100 (extended high temperature) Thread G ¾ A, G 1 A Tri-clamp (valve plug DIN 3650) (DIN ISO 228/1), ¾ NPT or 1 NPT (valve plug DIN 3650) 35 (1.38) 35 (1.38) L 0 (1.57) Ø 31.7 (1.25) 32 (1.26) G ¾ A, ¾ NPT G 1 A, 1 NPT Ø 21.3 (0.8) Switching point L 38 (1.5) Ø 31.7 (1.25) 32 (1.26) G ½ A, ½ NPT Ø 17 (0.67) Switching point ~ 88 (3.6) L 0 (1.57) Ø 31.7 (1.25) 32 G ¾ A, ¾ NPT G 1 A, 1 NPT Ø 21.3 (0.8) ~ 101 (3.98) L Switching point 13 (0.51) L = Length with G ¾ A, ¾ NPT: 66 (2.6) Length with G 1 A, 1 NPT: 69 (2.7) 11 (0.3) L = Length with G ½ A, ½ NPT: 62 (2.) 13 (0.51) L = Length with G ¾ A, ¾ NPT: 66 (2.6) Length with G 1 A, 1 NPT: 69 (2.7) Length with Tri-clamp: 53 (2.1) SITRANS LVL100 (standard with M12 connector) SITRANS LVL100 (extended, high temperature) Bolting DIN (valve plug DIN 3650) SMS 115 (valve plug DIN 3650) 10 (0.39) M12 x 1 10 (0.39) M12 x 1 L 0(1.57) Ø 31.7 (1.25) 32 G ¾ A, ¾ NPT G 1 A, 1 NPT Ø 21.3 (0.8) Switching point 65 (1.26) 38 (1.5) Ø 31.7 (1.25) SW 32 (1.26) G½ A, ½ NPT 17 (0.67) Switching point 0 (1.57) ~ 115 (.53) L ~ 105 (.13) L Switching point 13 (0.51) 11 (0.3) 13 (0.51) L = Length with G ¾ A, ¾ NPT: 66 (2.6) Length with G 1 A, 1 NPT: 69 (2.7) L = Length with G ½ A, ½ NPT: 62 (2.) L = Length with bolting: 53 (2.1) Length with SMS 115: 53 (2) SITRANS LVL100, dimensions in mm (inch) /86 Siemens FI 01 June 2015

87 Point level measurement - Vibrating switches SITRANS LVL100 Schematics Transistor PNP (M12 x 1 plug connection) Transistor PNP (with valve plug DIN 3650) Max Min. Max Min RL RL RL RL V DC V DC V DC V DC PA (Potential equalization) PA Contactless electronic switch (valve plug DIN 3650) Max. Min RL RL L1 N L1 N PE (protective ground) PE SITRANS LVL100, connections Siemens FI 01 June 2015 /87

88 Point level measurement - Vibrating switches SITRANS LVL200 Overview Configuration Horizontal mounting Switching point (recommended mounting position, particularly for adhesive applications) Marked with screwed version on top, with flange versions directed to the flange holes Vertical mounting SITRANS LVL200 is a standard vibrating level switch for material detection in liquid and slurry applications such as overflow, high, low, and demand applications, as well as pump protection. For use in SIL 2 applications. Benefits Proven vibrating level switch technology for liquids Compact insertion length of 0 mm (1.57 inch) for confined space applications Fault monitoring for corrosion, loss of vibration or line break to the piezo drive Functional Safety (SIL 2). Device suitable for use in accordance with IEC and IEC Hygienic process connections Application SITRANS LVL200 is a level switch designed for industrial use in all areas of process technology and can be used with liquids and slurries. With a tuning fork insertion length of only 0 mm (1.57 inch), SITRANS LVL200 can be mounted in small pipes and applications with confined space. The LVL200 can be used to measure products with a minimum density of > 0.5 g/cm³ (0.018 lb/in³). The LVL200 can be used in difficult conditions including turbulence, air bubbles, foam generation, buildup, or external vibration. SITRANS LVL200 continuously monitors faults via frequency evaluation, providing early detection of strong corrosion or damage on the tuning fork, loss of vibration, or a line break to the piezo drive. The tuning fork is piezoelectrically energized and vibrates at its mechanical resonance frequency of approximately Hz. The vibration frequency changes when the tuning fork is covered by the medium. This change is detected by the integrated oscillator and converted into a switching command. The integrated electronics evaluate the level signal and output a switching signal, directly operating connected devices. Key Applications: For use in liquids and slurries, for level measurement, overfill, and dry run protection Switching point [approx. 13 (0.51)] Mount away from filling openings or agitators. Moisture protection Switching point with higher density NOTE: Welded socket for flush mount optional Switching point with lower density Switching point [approx. 27 (1.06)] Ensure cable gland faces downward to avoid water ingress. SITRANS LVL200 installation, dimensions in mm (inch) /88 Siemens FI 01 June 2015

89 Point level measurement - Vibrating switches SITRANS LVL200 Technical specifications Mode of operation Measuring principle Input Measured variable Output Output options Vibrating point level switch High and low and demand (via mode switch) Relay output (DPDT), 2 floating SPDTs Contactless electronic switch 2 wire Namur signal output Measuring Accuracy Repeatability 0.1 mm (0.00 inch) Hysteresis Approx. 2 mm (0.08 inch) with vertical installation Switching delay Approx. 500 ms (on/off) Frequency Approx Hz Rated operating conditions Installation conditions Location Indoor/outdoor Ambient conditions Ambient temperature C ( F) Installation category III Pollution degree 2 Medium conditions Temperature - LVL200S Standard C ( F) - LVL200S High temperature option C ( F) - LVL200E Standard: C ( F) with 316L/Hastelloy - LVL200E High temperature option: C ( F) with 316L/Hastelloy Pressure (vessel) bar g ( psi g) Density g/cm³ ( lb/in³); g/cm³ ( lb/in³) by switching over Design Material Enclosure Aluminum die-cast AISi10Mg, powder-coated, basis: Polyester Stainless steel housing, electropolished 316L 316L (1.0 or 1.35), Hastelloy 316L (1.0 or 1.35), Hastelloy Tuning fork Extension tube [ø 21.3 mm (0.839 inch)] Process connection: threaded 316L (1.0 or 1.35), Hastelloy Process connection: flange 316L (1.0 or 1.35), 316L with Hastelloy, ECTFE, or PFA coating Process seal Klingersil C-00 Process connection Pipe thread, cylindrical (ISO 228 T1) G ¾" A, G 1" A Pipe thread, tapered ¾" NPT, 1" NPT, 1½" NPT Flanges DIN from DN25, ANSI from 1" Hygienic fittings Bolting DN 0 PN 0, 1, 1½, 2, 2½" Tri-Clamp PN 10, conus DN 25 PN 0, Tuchenhagen Varivent DN 50 PN 10, SMS Degree of protection Conduit entry Weight Device weight (dependent on process fitting) Tube extension (extended version) Power supply Supply voltage Relay DPDT Contactless 2 wire NAMUR Operating voltage (characteristics according to standard) for connection to an amplifier according to NAMUR Power consumption Relay DPDT Contactless 2 wire Namur Certificates and approvals Type X/NEMA X/IP66/IP67 1 x M20x1.5 (cable: ø mm), 1 x blind stopper M20x1.5; attached 1 x M20x1.5 cable entry 1 x ½" NPT cable entry, 1 x blind stopper ½" NPT, 1 x ½" NPT cable entry 1x M12x1; 1 x blind stopper M20x1.5 Approx kg ( lb) Approx. 920 g/m (10 oz/ft) V AC, 50/60 Hz, V DC [at U>60 V DC] V AC, 50/60 Hz, V DC IEC , approx. 8.2 V Off-load voltage U o approx. 8.2 V Short-circuit current I U approx. 8.2 ma VA (AC), approx. 1.3 W (DC) VA (AC), approx. 1.3 W (DC) Domestic current requirement approx. 3 ma (via load circuit) Load current - Min. 10 ma - Max. 00 ma [with I > 300 ma the ambient temperature can be max. 60 C (10 F)] - Max. A up to 0 ms (not WHG specified) Current consumption - Falling characteristics 2.6 ma uncovered/ 0.6 ma covered ma uncovered/ 2.6 ma covered - Failure message 0.6 ma CE, CSA Overfill Protection WHG and VLAREM II FM (Non-Incendive) Class I, Div. 2, Groups A, B, C, D FM (Explosion-Proof) Class I, Div. 1, Groups A, B, C, D; (Dust Ignition- Proof) Class II, III, Div. 1, Groups E, F, G1) IECEx d IIC T6...T2 Ga/Gb EHEDG ATEX II 1/2G, 2G EEx d IIC T6 ATEX II 1G, 1/2G, 2G EEx ia IIC T6 Shipping approvals BR-Ex d IIC T6... T2 FDA, 3A, Ehedge SIL/IEC61508 Declaration of Conformity [SIL-2 (min/max detection)] Siemens FI 01 June 2015 /89

90 Point level measurement - Vibrating switches SITRANS LVL200 SITRANS LVL200, Standard Compact vibrating level switch for material detection in liquid and slurry applications such as overflow, 7ML A 0 high, low, and demand applications, as well as pump protection. For use in SIL-2 and hazardous applications. Click on the for the online configuration in the PIA Life Cycle Portal. Electronics Contactless electronic switch V AC/DC 1 Double relay (DPDT) V DC/ V AC 2 NAMUR signal 1) Approvals Without approvals A Overfill protection (WHG) B ATEX II 1G, 1/2G, 2G EEx ia IIC T6 + WHG 2) C ATEX II 1/2G, 2G EEx d IIC T6 + WHG 3) D ATEX II 1G, 1/2G, 2G EEx ia IIC T6 + shipping E approvals 2) ATEX II 1/2G, 2G EEx d IIC T6 + shipping F approvals 3) ATEX II 1G, 1/2G, 2G EEx ia IIC T6 + ATEX II 1/2 D G IP6X T 2) IECEx Ex ia IIC T6 2) H Shipping approvals K FM (IS) Class I, II, III, Div. 1, Groups A, B, C, D, E, F, N G 2)) FM (XP) Class I, Div. 1, Groups A, B, C, D; (DIP) P Class II, III, Div. 1, Groups E, F, G 3)) FM (NI) Class I, Div. 2, Groups A, B, C, D ) Q IECEx d IIC T6...T2 Ga/Gb R CSA(XP)CL I, II, III Div. 1,Groups A,,B, C, D, E, F, G S CSA(NI)CL I, II, III, Div. 2, Groups A, B, C, D, E, F, G T BR-Ex d IIC T6...T2 U CSA (IS) CL I, II, III Div. 1, Groups A, B, C, D, E, F, V G 2) Process connection Thread G¾" A, PN 6/316L A 0 0 Thread G¾" A, PN 6/316L Ra < 0.8 µm A 0 1 Thread ¾" NPT, PN 6/316L A 0 2 Thread ¾" NPT, PN 6/316L Ra < 0.8 µm A 0 3 Thread ¾" NPT, PN 6/Monel A 0 Thread G¾" A, PN 6/Hastelloy A 0 5 Thread ¾" NPT, PN 6/Hastelloy A 0 6 Thread G1" A, PN 6/316L A 0 7 Thread G1" A, PN 6/316L ECTFE coated A 0 8 MB1982 5) Thread G1" A, PN 6/316L PFA coated 5) A 1 0 Thread G1" A, PN 6/Monel A 1 1 Thread G1" A, PN 6 / 316L Ra<0.8µm A 1 2 Thread G1" A, PN 6/316L Ra < 0.8 µm A 1 3 Thread 1" NPT, PN 6/316L 5) A 1 Thread 1" NPT, PN 6/316L ECTFE A 1 5 coatedmb1982 5) Thread 1" NPT, PN 6/316L PFA-coated A 1 6 Thread 1" NPT, PN 6/Monel A 1 7 Thread 1" NPT, PN 6/316L Ra < 0.8 µm A 1 8 Thread G1" A, PN 6/Hastelloy A 2 0 Thread G1½" A, PN 6/316L A 2 1 Thread G1½" A, PN 6/316L Ra<0,8µm A 2 2 Thread G1½" A, PN 6/Hastelloy A 2 3 Thread 1" NPT, PN 6/Hastelloy A 2 Thread 1½" NPT, PN 6/316L A 2 5 Thread 1½" NPT, PN 6/316L Ra<0,8µm A 2 6 Thread 1½" NPT, PN 6/Hastelloy A 2 7 Thread G2" A, PN 6/316L A 2 8 SITRANS LVL200, Standard Compact vibrating level switch for material detection in liquid and slurry applications such as overflow, 7ML A 0 high, low, and demand applications, as well as pump protection. For use in SIL-2 and hazardous applications. Thread M27x1.5, PN 6/316L A 3 0 Conus DN 25, PN 0/316L Ra < 0.3 µm A 3 1 Conus DN 25, PN 0/316L Ra < 0.8 µm A 3 2 Conus DN 25, PN 0/ECTFE (ZB3033) 5) A 3 3 Conus M52, PN 0/316L A 3 Conus M52, PN 0/316L Ra < 0.3 µm A 3 5 Conus M52, PN 0/316L Ra < 0.8 µm A 3 6 Tri-Clamp 1", PN 16/316L Ra < 0.3 µm A 3 7 Tri-Clamp 1", PN 16/Hastelloy A 3 8 Tri-Clamp 1", PN 16/316L Ra < 0.8 µm A 0 Tri-Clamp 1½", PN 16/316L Ra < 0.3 µm A 1 Tri-Clamp 1½", PN 16/Hastelloy A 2 Tri-Clamp 1½", PN 16/316L Ra < 0.8 µm A 3 Tri-Clamp 2", PN 16/316L Ra < 0.3 µm A Tri-Clamp 2", PN 16/Hastelloy A 5 Tri-Clamp 2", PN 16/316L Ra < 0.8 µm A 6 Tri-Clamp 2½", PN 10/316L Ra < 0.3 µm A 7 Tri-Clamp 2½", PN 10/316L Ra < 0.8 µm A 8 Tri-Clamp 3", PN 10/316L Ra < 0.3 µm A 5 0 Tri-Clamp 3", PN 10/316L Ra < 0.8 µm A 5 1 Bolting DN 32, PN 0 DIN11851/316L Ra < 0.3 µm A 5 2 Bolting DN 32, PN 0 DIN11851/316L Ra < 0.8 µm A 5 3 Bolting DN 25, PN 0 DIN11851/316L Ra < 0.3 µm A 5 Bolting DN 25, PN 0 DIN11851/316L Ra < 0.8 µm A 5 5 Bolting DN 0, PN 0 DIN11851/316L Ra < 0.3 µm A 5 6 Bolting DN 0, PN 0 DIN11851/316L Ra < 0.8 µm A 5 7 Bolting DN 0, PN 0 DIN A/316L Ra < 0.8 µm ZB3052 A 5 8 Bolting DN 50, PN 25 DIN11851/316L Ra < 0.3 µm A 6 0 Bolting DN 50, PN 25 DIN11851/316L Ra < 0.8 µm A 6 1 Bolting DN 50, PN 25 DIN A/316L A 6 2 Ra < 0.8 µm ZB3052 Hygienic w. compr. nut F0, PN 25/316L A 6 3 Hygienic w. compr. nut F0, PN 25/316L A 6 Ra < 0.3 µm Hygienic w. compr. nut F0, PN 25/316L A 6 5 Ra < 0.8 µm Varivent N50-0/316L Ra < 0.3 µm A 6 6 Varivent N50-0/316L Ra < 0.8 µm A 6 7 Varivent N125/100/316L Ra < 0.8 µm A 6 8 DRD flange, PN 0/316L ZB3007 A 7 0 SMS DN 38/316L Ra < 0.8 µm 5) A 7 1 SMS DN 51, PN 6/316L Ra < 0.8 µm 5) A 7 2 Swagelok VCR screwing ZG2579, PN 6/316L A 7 3 Neumo biocontrol size 25, PN 16/316L Ra < 0.8 µm A 7 Neumo biocontrol size 50, PN 16/316L Ra < 0.8 µm 5) A 7 5 Neumo biocontrol size 65, PN 16/316L Ra < 0.8 µm A 7 6 Neumo biocontrol size 80, PN 16/316L Ra < 0.8 µm A 7 7 SÜDMO DN 50, PN 10/316L Ra<0,8µm A 7 8 Small flange DN 25, PN 1.5 DIN 2803/316L pol. A 8 0 Ra < 0.8 µm Small flange DN 0, PN 1.5 DIN 2803/316L pol. A 8 1 Ra < 0.8 µm Ingold connection, PN 16/316L Ra < 0.8 µm A 8 2 Ingold connection, PN 16/Hastelloy A 8 3 Terminal DN 33.7 PN 0 DIN A-/316L BN2 A 8 Ra < 0.8 µm 5) Hygienic fl. DN 50 PN 16 DIN A-/316L Ra < 0.8 µm A 8 5 /90 Siemens FI 01 June 2015

91 Point level measurement - Vibrating switches SITRANS LVL200 SITRANS LVL200, Standard Compact vibrating level switch for material detection in liquid and slurry applications such as overflow, high, low, and demand applications, as well as pump protection. For use in SIL-2 and hazardous applications. 7ML A 0 Flange DN 25, PN 6 Form C, DIN 2501/316L A 8 6 Flange DN 25, PN 6 Form C, DIN 2501/PFA 5) A 8 7 Flange DN 25, PN 0 Form C, DIN 2501/316L A 8 8 Flange DN 25, PN 0 Form C, DIN 2501/Hastelloy B 0 0 Flange DN 25, PN 0 Form C, DIN 2501/ECTFE 5) B 0 1 Flange DN 25, PN 0 Form C, DIN 2501/PFA 5) B 0 2 Flange DN 25, PN 0 Form C, DIN 2501/Enamelled B 0 3 Flange DN 25, PN 0 Form D, DIN 2501/316L B 0 Flange DN 25, PN 0 Form F, DIN 2501/316L B 0 5 Flange DN 25, PN 0 Form N, DIN 2501/316L B 0 6 Flange DN 25, PN 0 Form N, DIN 2501/Hastelloy B 0 7 Flange DN 25, PN 0 Form N, DIN 2501/Monel B 0 8 solid Flange DN 25, PN 0 V13, DIN 2501/316L B 1 0 Flange DN 32, PN 0 Form C, DIN 2501/316L B 1 1 Flange DN 32, PN 0 Form C, DIN 2501/ECTFE 5) B 1 2 Flange DN 0, PN 6 Form C, DIN 2501/316L B 1 3 Flange DN 0, PN 6 Form C, DIN 2501/ECTFE 5) B 1 Flange DN 0, PN 0 Form C, DIN 2501/316L B 1 5 Flange DN 0, PN 0 Form C, DIN 2501/Hastelloy B 1 6 Flange DN 0, PN 0 Form C, DIN 2501/ECTFE 5) B 1 7 Flange DN 0, PN 0 Form C, DIN 2501/PFA 5) B 1 8 Flange DN 0, PN 0 Form C, DIN 2501/ Enamelled 6) B 2 0 Flange DN 0, PN 0 Form F, DIN 2501/316L B 2 1 Flange DN 0, PN 0 Form N, DIN 2501/316L B 2 2 Flange DN 0, PN 0 Form E, DIN 2501/316L B 2 3 Flange DN 0, PN 0 V13, DIN 2501/316L B 2 Flange DN 50, PN 0 Form C, DIN 2501/316L B 2 5 Flange DN 50, PN 0 Form C, DIN 2501/Hastelloy B 2 6 Flange DN 50, PN 0 Form C, DIN 2501/ECTFE 5) B 2 7 Flange DN 50, PN 0 Form C, DIN 2501/ ECTFE (ZB3108) 5) B 2 8 Flange DN 50, PN 0 Form C, DIN 2501/PFA 5) B 3 0 Flange DN 50, PN 0 Form D, DIN 2501/316L B 3 1 Flange DN 50, PN 0 Form D, DIN 2501/Hastelloy B 3 2 Flange DN 50, PN 0 Form F, DIN 2501/316L B 3 3 Flange DN 50, PN 0 Form N, DIN 2501/316L B 3 Flange DN 50, PN 0 Form N, DIN 2501/Hastelloy B 3 5 Flange DN 50, PN 0 Form E, DIN 2501/316L B 3 6 Flange DN 50, PN 0 V13, DIN 2501/316L B 3 7 Flange DN 50, PN 0 R13, DIN 2501/316L B 3 8 Flange DN 50, PN 6 Form F, DIN 2501/316L B 0 Flange DN 50, PN 6 Form N, DIN 2501/Hastelloy B 1 Flange DN 50, PN 6 Form C, DIN 2501/316L B 2 Flange DN 50, PN 6 Form L, DIN 2501/316L B 3 Flange DN 50, PN 100 Form E, DIN 2501/316L B Flange DN 50, PN 100 Form L, DIN 2501/316L B 5 Flange DN 65, PN 0 Form C, DIN 2501/316L B 6 Flange DN 65, PN 0 Form C, DIN 2501/Hastelloy B 7 Flange DN 65, PN 0 Form C, DIN 2501/ECTFE 5) B 8 Flange DN 65, PN 0 Form C, DIN 2501/PFA 5) B 5 0 Flange DN 65, PN 0 Form F, DIN 2501/316L B 5 1 Flange DN 65, PN 6 Form E, DIN 2501/316L B 5 2 Flange DN 80, PN 0 Form C, DIN 2501/316L B 5 3 Flange DN 80, PN 0 Form C, DIN 2501/ Hastelloy B 5 Flange DN 80, PN 0 Form C, DIN 2501/ECTFE 5) B 5 5 SITRANS LVL200, Standard Compact vibrating level switch for material detection in liquid and slurry applications such as overflow, 7ML A 0 high, low, and demand applications, as well as pump protection. For use in SIL-2 and hazardous applications. Flange DN 80, PN 0 Form C, DIN 2501/PFA 5) B 5 6 Flange DN 80, PN 0 Form C, DIN 2501/ Enamelled 6) B 5 7 Flange DN 80, PN 0 Form F, DIN 2501/316L B 5 8 Flange DN 80, PN 0 Form N, DIN 2501/316L B 6 0 Flange DN 100, PN 16 Form C, DIN 2501/316L B 6 2 Flange DN 100, PN 16 Form C, DIN 2501/Hastelloy B 6 3 Flange DN 100, PN 16 Form C, DIN 2501/ECTFE 5) B 6 Flange DN 100, PN 16 Form C, DIN 2501/PFA 5) B 6 5 Flange DN 100, PN 16 Form C, DIN 2501/ Enamelled 6) B 6 6 Flange DN 100, PN 16 Form D, DIN 2501/316L B 6 7 Flange DN 100, PN 16 Form F, DIN 2501/316L B 6 8 Flange DN 100, PN 16 Form N, DIN 2501/316L B 7 0 Flange DN 100, PN 0 Form C, DIN 2501/316L B 7 1 Flange DN 100, PN 0 Form C, DIN 2501/ECTFE 5) B 7 2 Flange DN 100, PN 0 Form C, DIN 2501/PFA 5) B 7 3 Flange DN 100, PN 0 Form C, DIN 2501/ Enamelled 6) B 7 Flange DN 100, PN 0 Form F, DIN 2501/316L B 7 5 Flange DN 100, PN 0 Form N, DIN 2501/316L B 7 6 Flange DN 100, PN 0 V13, DIN 2501/316L B 7 7 Flange DN 100, PN 6 Form E, DIN 2501/316L B 7 8 Flange DN 100, PN 100 Form E, DIN 2501/316L B 8 0 Flange DN 100, PN 100 Form L, DIN 2501/316L B 8 1 Flange DN 125, PN 16 Form F, DIN 2501/316L B 8 2 Flange DN 125, PN 0 Form C, DIN 2501/316L B 8 3 Flange DN 125, PN 0 Form N, DIN 2512/ 316L B 8 Flange DN 150, PN 16 Form C, DIN 2501/316L B 8 5 Flange DN 150, PN 16 Form C, DIN 2501/Hastelloy B 8 6 Flange DN 150, PN 16 Form C, DIN 2501/ECTFE 5) B 8 7 Flange DN 150, PN 16 Form C, DIN 2501/PFA 5) B 8 8 Flange DN 150, PN 16 Form D, DIN 2501/316L C 0 0 Flange DN 150, PN 0 Form C, DIN 2501/316L C 0 1 Flange DN 150, PN 0 Form C, DIN 2501/Hastelloy C 0 2 Flange DN 150, PN 0 Form F, DIN 2501/316L C 0 3 Flange DN 150, PN 0 Form N, DIN 2512/316L C 0 Flange DN 200, PN 10 Form C, DIN 2501/ECTFE 5) C 0 5 Flange DN 200, PN 16 Form C, DIN 2501/316L C 0 6 Flange DN 25, PN 0 Form B1, EN /316L C 0 7 Flange DN 25, PN 0 Form B1, EN /Hastelloy C 0 8 Flange DN 25, PN 0 Form B1, EN/ 316L/ PFA 5) C 1 0 Flange DN 25, PN 0 Form B1, EN / Enamelled 6) C 1 1 Flange DN 25, PN 0 Form B2, EN /316L C 1 2 Flange DN 25, PN 0 Form F, EN /316L C 1 3 Flange DN 25, PN 63 Form B1, EN /316L C 1 Flange DN 25, PN 100 Form B2, EN /316L C 1 5 Flange DN 0, PN 0 Form B1, EN/ 316L C 1 6 Flange DN 0, PN 0 Form B1, EN /PFA 5) C 1 7 Flange DN 0, PN 0 Form B2, EN/316L C 1 8 Flange DN 50, PN 0 Form B1, EN/316L C 2 0 Flange DN 50, PN 0 Form B1, EN / C 2 1 Hastelloy Flange DN 50, PN 0 Form B1, EN / C 2 2 Monel ZB2977 Flange DN 50, PN 0 Form B1, EN /ECTFE 5) C 2 3 Flange DN 50, PN 0 Form B1, EN/ 316L/PFA 5) C 2 Siemens FI 01 June 2015 /91

92 Point level measurement - Vibrating switches SITRANS LVL200 SITRANS LVL200, Standard 7ML576- Compact vibrating level switch for material detection in liquid and slurry applications such as overflow, A 0 high, low, and demand applications, as well as pump protection. For use in SIL-2 and hazardous applications. Flange DN 50, PN 0 Form B1, EN / Enamelled 6) C 2 5 Flange DN 50, PN 0 Form C, EN /316L C 2 6 Flange DN 50, PN 0 Form D, EN/316L C 2 7 Flange DN 50, PN 0 Form D, EN /Hastelloy C 2 8 Flange DN 50, PN 0 Form B2, EN /316L C 3 0 Flange DN 50, PN 0 Form E, EN /316L C 3 1 Flange DN 80, PN 0 Form B1, EN /316L C 3 2 Flange DN 80, PN 0 Form B1, EN /Hastelloy C 3 3 Flange DN 80, PN 0 Form B1, EN /ECTFE 5) C 3 Flange DN 80, PN 0 Form B1, EN / Enamelled 6) C 3 5 Flange DN 80, PN 0 Form B2, EN /316L C 3 6 Flange DN 100, PN 16 Form B1, EN /316L C 3 7 Flange DN 100, PN 16 Form B1, EN / C 3 8 Hastelloy Flange DN 100, PN 16 Form B1, EN / Enamelled 6) C 0 Flange DN 100, PN 0 Form B1, EN /316L C 1 Flange DN 100, PN 0 Form B1, EN / Enamelled 6) C 2 Flange DN 100, PN 0 Form C, EN /316L C 3 Flange DN 100, PN 63 Form B2, EN /316L C Flange DN 150, PN 16 Form B1, EN /316L C 5 Flange DN 150, PN 16 Form B1, EN /PFA 5) C 6 Flange DN 150, PN 0 Form B1, EN /316L C 7 Flange DN 150, PN 0 Form B1, EN / ECTFE 5) C 8 Flange DN 150, PN 0 Form B2, EN /316L C 5 0 Flange 1" 150 lb ANSI B16.5/316L C 5 1 Flange 1" 150 lb RF, ANSI B16.5/Hastelloy C 5 2 Flange 1" 150 lb RF, ANSI B16.5/Monel ZB2977 C 5 3 Flange 1" 150 lb RF, ANSI B16.5/ECTFE 5) C 5 Flange 1" 150 lb RF, ANSI B16.5/PFA 5) C 5 5 Flange 1" 150 lb RF, ANSI B16.5/Enamelled 6) C 5 6 Flange 1" 300 lb RF, ANSI B16.5/316L C 5 7 Flange 1" 300 lb RF, ANSI B16.5/ECTFE 5) C 5 8 Flange 1" 600 lb RF, ANSI B16.5/316L C 6 0 Flange 1½" 150 lb RF, ANSI B16.5/316L C 6 1 Flange 1½" 150 lb RF, ANSI B16.5/Hastelloy C 6 2 Flange 1½" 150 lb RF, ANSI B16.5/ECTFE 5) C 6 3 Flange 1½" 150 lb RF, ANSI B16.5/PFA 5) C 6 Flange 1½" 150 lb RF, ANSI B16.5 Enamelled 6) C 6 5 Flange 1½" 150 lb FF, ANSI B16.5/ECTFE 5) C 6 6 Flange 1½" 300 lb RF, ANSI B16.5/316L C 6 7 Flange 1½" 300 lb RF, ANSI B16.5/Monel ZB2977 C 6 8 Flange 1½" 300 lb RF, ANSI B16.5/ECTFE 6) C 7 0 Flange 1½" 600 lb RF, ANSI B16.5/316L C 7 1 Flange 2" 150 lb RF, ANSI B16.5/316L C 7 2 Flange 2" 150 lb RF, ANSI B16.5/Hastelloy C 7 3 Flange 2" 150 lb RF, ANSI B16.5/Monel ZB2977 C 7 Flange 2" 150 lb RF, ANSI B16.5/ECTFE 5) C 7 5 Flange 2" 150 lb RF, ANSI B16.5/PFA 5) C 7 6 Flange 2" 150 lb RF, ANSI B16.5/Enamelled 6) C 7 7 Flange 2" 150 lb FF, ANSI B16.5/316L C 7 8 Flange 2" 150 lb FF, ANSI B16.5/ECTF 5) C 8 0 Flange 2" 150 lb SG (small groove), C 8 1 ANSI B16.5/316L SITRANS LVL200, Standard Compact vibrating level switch for material detection in liquid and slurry applications such as overflow, 7ML A 0 high, low, and demand applications, as well as pump protection. For use in SIL-2 and hazardous applications. Flange 2" 300 lb RF, ANSI B16.5/316L C 8 2 Flange 2" 300 lb RF, ANSI B16.5/Hastelloy C 8 3 Flange 2" 300 lb RF, ANSI B16.5/ECTFE 5) C 8 5 Flange 2" 300 lb RF, ANSI B16.5/PFA 5) C 8 6 Flange 2" 300 lb RF, ANSI B16.5 Enamelled 6) C 8 7 Flange 2" 300 lb RJF, ANSI B16.5/316L C 8 8 Flange 2" 300 lb ST, ANSI B16.5/316L D 0 0 Flange 2" 300 lb LG (large groove), D 0 1 ANSI B16.5/316L Flange 2" 300 lb LT, ANSI B16.5/316L D 0 2 Flange 2" 600 lb RF, ANSI B16.5/316L D 0 3 Flange 2" 600 lb RF, ANSI B16.5/Monel ZB2977 D 0 Flange 2" 600 lb RF, ANSI B16.5/ECTFE 5) D 0 5 Flange 2" 600 lb RJF, ANSI B16.5/316L D 0 6 Flange 2" 600 lb LG, ANSI B16.5/316L D 0 7 Flange 2" 900 lb RJF, ANSI B16.5/316L D 0 8 Flange 2½" 150 lb RF, ANSI B16.5/316L D 1 0 Flange 2½" 300 lb RF, ANSI B16.5/316L D 1 1 Flange 3" 150 lb RF, ANSI B16.5/316L D 1 2 Flange 3" 150 lb RF, ANSI B16.5/Hastelloy D 1 3 Flange 3" 150 lb RF, ANSI B16.5/ECTFE 5) D 1 Flange 3" 150 lb RF, ANSI B16.5/PFA 5) D 1 5 Flange 3" 150 lb RF, ANSI B16.5/Enamelled 6) D 1 6 Flange 3" 150 lb FF, ANSI B16.5/316L D 1 7 Flange 3" 150 lb FF, ANSI B16.5/ECTFE 5) D 1 8 Flange 3" 150 lb FF, ANSI B16.5/PFA 5) D 2 0 Flange 3" 300 lb RF, ANSI B16.5/316L D 2 1 Flange 3" 300 lb RF, ANSI B16.5/Hastelloy D 2 2 Flange 3" 300 lb RF, ANSI B16.5/ECTFE 5) D 2 3 Flange 3" 300 lb RF, ANSI B16.5/PFA 5) D 2 Flange 3" 300 lb RF, ANSI B16.5/Enamelled 6) D 2 5 Flange 3" 600 lb RF, ANSI B16.5/316L D 2 6 Flange 3½" 150 lb RF, ANSI B16.5/316L D 2 7 Flange 3½" 150 lb RF, ANSI B16.5/ECTFE 5) D 2 8 Flange " 150 lb RF, ANSI B16.5/316L D 3 0 Flange " 150 lb RF, ANSI B16.5/Hastelloy D 3 1 Flange " 150 lb RF, ANSI B16.5/ECTFE 5) D 3 2 Flange " 150 lb RF, ANSI B16.5/PFA 5) D 3 3 Flange " 150 lb RF, ANSI B16.5/Enamelled 6) D 3 Flange " 150 lb LT, ANSI B16.5/316L D 3 5 Flange " 300 lb RF, ANSI B16.5/316L D 3 6 Flange " 300 lb RF, ANSI B16.5/Hastelloy D 3 7 Flange " 300 lb RF, ANSI B16.5/ECTFE 5) D 3 8 Flange " 300 lb RJF, ANSI B16.5/316L D 0 Flange " 300 lb LG, ANSI B16.5/316L D 1 Flange " 300 lb LT, ANSI B16.5/316L D 2 Flange " 600 lb RF, ANSI B16.5/316L D 3 Flange " 600 lb RJF, ANSI B16.5/316L D Flange 6" 150 lb RF, ANSI B16.5/316L D 5 Flange 6" 150 lb RF, ANSI B16.5/Hastelloy D 6 Flange 6" 150 lb RF, ANSI B16.5/ECTFE 5) D 7 Flange 6" 150 lb RF, ANSI B16.5/PFA 5) D 8 Flange 6" 150 lb RJF, ANSI B16.5/316L D 5 0 Flange 6" 300 lb RF, ANSI B16.5/316L D 5 1 Flange 8" 150 lb RF, ANSI B16.5/316L D 5 2 Flange 8" 150 lb RF, ANSI B16.5/ECTFE 5) D 5 3 Flange 1" BS.10 Table E/316L D 5 /92 Siemens FI 01 June 2015

93 Point level measurement - Vibrating switches SITRANS LVL200 SITRANS LVL200, Standard 7ML576- Compact vibrating level switch for material detection in liquid and slurry applications such as overflow, A 0 high, low, and demand applications, as well as pump protection. For use in SIL-2 and hazardous applications. Flange 1" BS.10 Table E/PFA 5) D 5 5 Flange 1½" BS.10 Table E/316L D 5 6 Flange 3½" BS.10 Table E/316L D 5 7 Flange " BS.10 Table E/ECTFE 5) D 5 8 Flange DN 0 10K, JIS/316L D 6 0 Flange DN 50 10K, JIS/316L D 6 1 Flange DN 80 10K, JIS/316L D 6 2 Flange DN K, JIS/316L D 6 3 Adapter/Process temperature Without adapter/ C ( F) 1 With adapter/ C ( F) 7) 2 With adapter/ C ( F) 3 With gas-tight leadthrough/ C ( F) With gas-tight leadthrough/ C 5 ( F) Housing/ Cable entry Aluminium IP66/IP67/M20x1.5 A Aluminium IP66/IP67/½" NPT B 316L stainless steel (electropolished) C IP66/IP67/M20X1.5 8)9) 316L stainless steel (electropolished) IP66/IP67/½" NPT 8)9) D 1) Available with Adapter/Process temperature options 1, 3,, and 5 only 2) Available with Electronics option only 3) Available with Adapter/Process temperature options 1 and 3 only ) Available with Housing/Cable entry option B only 5) Available with Adapter/Process temperature options 1 and only 6) Available with Adapter/Process temperature options 1, 2, and only 7) Available with enamelled Process connection options only 8) Available with Approval options A, B, C only 9) Not available with SIL/IEC61508 Certificate of conformity (SIL-2 min. and max. detection) We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 9/5 in the appendix. Further designs Please add "-Z" to and specify Order code(s). Cleaning including Certificate (oil, grease, and silicone free) Identification Label (measurement loop) stainless steel: max. 16 characters add in plain text Identification Label (measurement loop) Foil: max. 16 characters add in plain text 3.1-Inspection Certificate for material (EN 1020 NACE MR 0175) 1) 2.2-Factory certificate for material (EN 1020) 1) Order code W01 Y17 Y18 D07 C15 Order code Functional Safety (SIL 2). Device suitable for use in C20 accordance with IEC and IEC ) Dye penetration test certificate/instrument 1) C13 X-ray test certificate/instrument 1) C1 Positive material identification test C certificate/instrument 1) Roughness test certificate/instrument 1) C Inspection Certificate for instrument with test C25 data (EN 1020) Quality and test plan C26 Pressure test certificate/instrument 1) C31 Helium leak test certificate/instrument 1) C32 Ferrite measuring accuracy to DIN C certificate/instrument 1) Pressure test according to Norsok C certificate/instrument 1) Additional Operating Instructions LVL200 (DPDT Relay) English 7ML1998-5KR01 French 7ML1998-5KR11 Spanish 7ML1998-5KR21 German 7ML1998-5KR31 LVL200 (Contactless electronic switch) English 7ML1998-5KQ01 French 7ML1998-5KQ11 Spanish 7ML1998-5KQ21 German 7ML1998-5KQ31 Electronics module LVL200 Relay English 7ML1998-5LS01 French 7ML1998-5LS11 Spanish 7ML1998-5LS21 German 7ML1998-5LS31 This device is shipped with the Siemens Milltronics manual DVD containing the Operating Instructions library. Spare Parts and Accessories Electronics module SITRANS LVL200 Relay 7ML1830-1NC Electronics module SITRANS LVL200 Contactless 7ML1930-6AA LVL200 Threaded Welded Socket G¾" A/316L with FKM Seal G1" A/316L with FKM Seal M27x1.5/316L with FKM Seal G¾" A/316L with EPDM Seal G1" A/316L with EPDM Seal M27x1.5/316L with EPDM Seal 7ML1930-1EE 7ML1930-1EF 7ML1930-1EG 7ML1930-1EH 7ML1930-1EJ 7ML1930-1EK 1) Listed Certificates are not available with all configurations, please contact factory for more information Siemens FI 01 June 2015 /93

94 Point level measurement - Vibrating switches SITRANS LVL200 SITRANS LVL200, Rigid extension Compact vibrating level switch for material detection in liquid applications such as overflow, high, 7ML low, and demand applications, as well as pump protection. For use in SIL-2 and hazardous applications. Click on the for the online configuration in the PIA Life Cycle Portal. Electronics Contactless electronic switch V AC/DC 1 Double relay (DPDT) V DC/ V AC 2 NAMUR signal 1) Approvals Without approvals A Overfill protection (WHG) B ATEX II 1G, 1/2G, 2G EEx ia IIC T6 + WHG 2) C ATEX II 1/2G, 2G EEx d IIC T6 + WHG 3)) D ATEX II 1G, 1/2G, 2G EEx ia IIC T6 + shipping E approvals 2) ATEX II 1/2G, 2G EEx d IIC T6 + shipping F approvals 3)) ATEX II 1G, 1/2G, 2G EEx ia IIC T6 + ATEX II 1/2D G IP6X T 2) IECEx Ex ia IIC T6 2) H Shipping approvals K FM (IS) Class I, II, III, Div. 1, Groups A, B, C, D, E, F, G 2)5) N FM (XP) Class I, Div. 1, Groups A, B, C, D; (DIP) P Class II, III, Div. 1, Groups E, F, G 3))5) FM (NI) Class I, Div. 2, Groups A, B, C, D 5) Q IECEx d IIC T6...T2 Ga/Gb ) R CSA(XP)CL I,II,III Div. 1,Groups A, B, C, D, E, F, S G...T2 ) Ga/Gb CSA(NI)CL I,II,III, Div. 2,Groups A, B, C, D, E, F, G T BR-Ex d IIC T6...T2 U CSA (IS) CL I, II, III Div. 1, Groups A, B, C, D, E, F, V G 2) Process connection Thread G¾" A, PN 6/316L A 0 0 Thread G¾" A, PN 6/316L Ra < 0.8 µm A 0 1 Thread ¾" NPT, PN 6/316L A 0 2 Thread ¾" NPT, PN 6/316L Ra < 0.8 µm A 0 3 Thread ¾" NPT, PN 6/Monel A 0 Thread G¾" A, PN 6/Hastelloy A 0 5 Thread ¾" NPT, PN 6/Hastelloy A 0 6 Thread G1" A, PN 6/316L A 0 7 Thread G1" A, PN 6/316L ECTFE coated MB1982 6) A 0 8 Thread G1" A, PN 6/316L PFA coated 6) A 1 0 Thread G1" A, PN 6/Monel A 1 1 Thread G1" A, PN 6/316L Ra < 0.8 µm A 1 3 Thread 1" NPT, PN 6/316L A 1 Thread 1" NPT, PN 6/316L ECTFE coated MB1982 6) A 1 5 Thread 1" NPT, PN 6/316L PFA coated 6) A 1 6 Thread 1" NPT, PN 6/Monel A 1 7 Thread 1" NPT, PN 6/316L Ra < 0.8 µm A 1 8 Thread G1" A, PN 6/Hastelloy A 2 0 Thread G1½" A, PN 6/316L A 2 1 Thread G1½" A, PN 6/316L Ra <0.8 µm A 2 2 Thread G1½" A, PN 6/Hastelloy A 2 3 Thread 1" NPT, PN 6/Hastelloy A 2 Thread 1½" NPT, PN 6/316L A 2 5 Thread 1½" NPT, PN 6/316L Ra< 0.8 µm A 2 6 Thread 1½" NPT, PN 6/Hastelloy A 2 7 Thread G2" A, PN 6/316L A 2 8 Thread M27x1.5 PN 6/316L A 3 0 SITRANS LVL200, Rigid extension Compact vibrating level switch for material detection in liquid applications such as overflow, high, 7ML low, and demand applications, as well as pump protection. For use in SIL-2 and hazardous applications. Cyl. socket/316ti/1.581 ECTFE coated ZB298 6) A 3 1 Conus DN 25 PN 0/316L Ra < 0.3 µm A 3 2 Conus DN 25 PN 0/316L Ra < 0.8 µm. A 3 3 Conus DN 25 PN 0/ECTFE (ZB3033) 6) A 3 Conus M52 PN 0/316L A 3 5 Conus M52 PN 0/316L Ra < 0.3 µm A 3 6 Conus M52 PN 0/316L Ra < 0.8 µm A 3 7 Tri-Clamp 1" PN 16/316L Ra < 0.3 µm A 3 8 Tri-Clamp 1" PN 16/Hastelloy A 0 Tri-Clamp 1" PN 16/316L Ra < 0.8 µm A 1 Tri-Clamp 1½" PN 16/316L Ra < 0.3 µm A 2 Tri-Clamp 1½" PN 16/Hastelloy A 3 Tri-Clamp 1½" PN 16/316L Ra < 0.8 µm A Tri-Clamp 2" PN 16/316L Ra < 0.3 µm A 5 Tri-Clamp 2" PN 16/Hastelloy A 6 Tri-Clamp 2" PN 16/316L Ra < 0.8 µm A 7 Tri-Clamp 2½" PN 10/316L Ra < 0.3 µm A 8 Tri-Clamp 2½" PN 10/316L Ra < 0.8 µm A 5 0 Tri-Clamp 3" PN 10/316L Ra < 0.3 µm A 5 1 Tri-Clamp 3" PN 10/316L Ra < 0.8 µm A 5 2 Bolting DN 32 PN 0 DIN11851/316L Ra < 0.3 µm A 5 3 Bolting DN 32 PN 0 DIN11851/316L Ra < 0.8 µm A 5 Bolting DN 25 PN 0 DIN11851/316L Ra < 0.3 µm A 5 5 Bolting DN 25 PN 0 DIN11851/316L Ra < 0.8 µm A 5 6 Bolting DN 0 PN 0 DIN11851/316L Ra < 0.3 µm A 5 7 Bolting DN 0 PN 0 DIN11851/316L Ra < 0.8 µm A 5 8 Bolting DN 0 PN 0 DIN A/316L A 6 0 Ra < 0.8 µm ZB3052 Bolting DN 50 PN 25 DIN11851/316L Ra < 0.3 µm A 6 1 Bolting DN 50 PN 25 DIN11851/316L Ra < 0.8 µm A 6 2 Bolting DN 50 PN 25 DIN A/316L A 6 3 Ra < 0.8 µm ZB3052 Hygienic w.compr.nut F0 PN 25/316L A 6 Hygienic w.compr.nut F0 PN 25/316L Ra < 0.3 µm A 6 5 Hygienic w.compr.nut F0 PN 25/316L Ra < 0.8 µm A 6 6 Varivent N50-0/316L Ra < 0.3 µm A 6 7 Varivent N50-0/316L Ra < 0.8 µm A 6 8 Varivent N125/100/316L Ra < 0.8 µm A 7 0 DRD flange PN 0/316L ZB3007 A 7 1 SMS DN 38/316L Ra < 0.8 µm 6) A 7 2 SMS DN 51 PN 6/316L Ra < 0.8 µm 6) A 7 3 Swagelok VCR screwing ZG2579 PN 6/316L A 7 Neumo biocontrol size 25 PN 16/316L Ra < 0.8 µm A 7 5 Neumo biocontrol size 50 PN 16/316L Ra < 0.8 µm A 7 6 Neumo biocontrol size 65 PN 16/316L Ra < 0.8 µm A 7 7 Neumo biocontrol size 80 PN 16/316L Ra < 0.8 µm A 7 8 SÜDMO DN 50 PN 10/316L Ra < 0.8 µm A 8 0 Small flange DN 25 PN 1.5 DIN 2803/316L pol. A 8 1 Ra<0.8 µm Small flange DN 0 PN 1.5 DIN 2803/316L pol. A 8 2 Ra<0.8 µm Ingold connection PN 16/316L Ra < 0.8 µm A 8 3 Terminal DN 33.7 PN 0 DIN A-/316L BN2 A 8 Ra < 0.8 µm Hygienic fl. DN 50 PN 16 DIN A-/316L A 8 5 Ra<0.8 µm Flange DN 25 PN 6 Form C, DIN 2501/316L A 8 6 /9 Siemens FI 01 June 2015

95 Point level measurement - Vibrating switches SITRANS LVL200 Flange DN 25 PN 6 Form C, DIN 2501/PFA 6) A 8 7 Flange DN 25 PN 0 Form C, DIN 2501/316L A 8 8 Flange DN 25 PN 0 Form C, DIN 2501/Hastelloy B 0 0 Flange DN 25 PN 0 Form C, DIN 2501/ECTFE 6) B 0 1 Flange DN 25 PN 0 Form C, DIN 2501/PFA 6) B 0 2 Flange DN 25 PN 0 Form D, DIN 2501/316L B 0 3 Flange DN 25 PN 0 Form F, DIN 2501/316L B 0 Flange DN 25 PN 0 Form N, DIN 2501/316L B 0 5 Flange DN 25 PN 0 Form N, DIN 2501/Hastelloy B 0 6 Flange DN 25 PN 0 Form N, DIN 2501/Monel solid B 0 7 Flange DN 25 PN 0 V13, DIN 2501/316L B 0 8 Flange DN 32 PN 0 Form C, DIN 2501/316L B 1 0 SITRANS LVL200, Rigid extension Compact vibrating level switch for material detection in liquid applications such as overflow, high, low, and demand applications, as well as pump protection. For use in SIL-2 and hazardous applications. 7ML Flange DN 32 PN 0 Form C, DIN 2501/ECTFE 6) B 1 1 Flange DN 0 PN 6 Form C, DIN 2501/316L B 1 2 Flange DN 0 PN 6 Form C, DIN 2501/ECTFE 6) B 1 3 Flange DN 0 PN 0 Form C, DIN 2501/316L B 1 Flange DN 0 PN 0 Form C, DIN 2501/Hastelloy B 1 5 Flange DN 0 PN 0 Form C, DIN 2501/ECTFE 6) B 1 6 Flange DN 0 PN 0 Form C, DIN 2501/PFA 6) B 1 7 Flange DN 0 PN 0 Form C, DIN 2501/Enamelled 7) B 1 8 Flange DN 0 PN 0 Form F, DIN 2501/316L B 2 0 Flange DN 0 PN 0 Form N, DIN 2501/316L B 2 1 Flange DN 0 PN 0 Form E, DIN 2501/316L B 2 2 Flange DN 0 PN 0 V13, DIN 2501/316L B 2 3 Flange DN 50 PN 0 Form C, DIN 2501/316L B 2 Flange DN 50 PN 0 Form C, DIN 2501/Hastelloy B 2 5 Flange DN 50 PN 0 Form C, DIN 2501/ECTFE 6) B 2 6 Flange DN 50 PN 0 Form C, DIN 2501/ECTFE (ZB3108) 6) B 2 7 Flange DN 50 PN 0 Form C, DIN 2501/PFA 6) B 2 8 Flange DN 50 PN 0 Form D, DIN 2501/316L B 3 0 Flange DN 50 PN 0 Form D, DIN 2501/Hastelloy B 3 1 Flange DN 50 PN 0 Form F, DIN 2501/316L B 3 2 Flange DN 50 PN 0 Form N, DIN 2501/316L B 3 3 Flange DN 50 PN 0 Form N, DIN 2501/Hastelloy B 3 Flange DN 50 PN 0 Form E, DIN 2501/316L B 3 5 Flange DN 50 PN 0 V13, DIN 2501/316L B 3 6 Flange DN 50 PN 0 R13, DIN 2501/316L B 3 7 Flange DN 50 PN 6 Form F, DIN 2501/316L B 3 8 Flange DN 50 PN 6 Form N, DIN 2501/Hastelloy B 0 Flange DN 50 PN 6 Form C, DIN 2501/316L B 1 Flange DN 50 PN 6 Form L, DIN 2501/316L B 2 Flange DN 50 PN 100 Form E, DIN 2501/316L B 3 Flange DN 50 PN 100 Form L, DIN 2501/316L B Flange DN 65 PN 0 Form C, DIN 2501/316L B 5 Flange DN 65 PN 0 Form C, DIN 2501/Hastelloy B 6 Flange DN 65 PN 0 Form C, DIN 2501/ECTFE 6) B 7 Flange DN 65 PN 0 Form C, DIN 2501/PFA 6) B 8 Flange DN 65 PN 0 Form F, DIN 2501/316L B 5 0 Flange DN 65 PN 6 Form E, DIN 2501/316L B 5 1 Flange DN 80 PN 0 Form C, DIN 2501/316L B 5 2 Flange DN 80 PN 0 Form C, DIN 2501/Hastelloy B 5 3 Flange DN 80 PN 0 Form C, DIN 2501/ECTFE 6) B 5 Flange DN 80 PN 0 Form C, DIN 2501/PFA 6) B 5 5 Flange DN 80 PN 0 Form F, DIN 2501/316L B 5 6 SITRANS LVL200, Rigid extension Compact vibrating level switch for material detection in liquid applications such as overflow, high, 7ML low, and demand applications, as well as pump protection. For use in SIL-2 and hazardous applications. Flange DN 80 PN 0 Form N, DIN 2501/316L B 5 7 Flange DN 80 PN 0 Form N, DIN 2501/Hastelloy B 5 8 Flange DN 100 PN 16 Form C, DIN 2501/316L B 6 0 Flange DN 100 PN 16 Form C, DIN 2501/Hastelloy B 6 1 Flange DN 100 PN 16 Form C, DIN 2501/ECTFE 6) B 6 2 Flange DN 100 PN 16 Form C, DIN 2501/PFA 6) B 6 3 Flange DN 100 PN 16 Form D, DIN 2501/316L B 6 Flange DN 100 PN 16 Form F, DIN 2501/316L B 6 5 Flange DN 100 PN 16 Form N, DIN 2501/316L B 6 6 Flange DN 100 PN 0 Form C, DIN 2501/316L B 6 7 Flange DN 100 PN 0 Form C, DIN 2501/ECTFE 6) B 6 8 Flange DN 100 PN 0 Form C, DIN 2501/PFA 6) B 7 0 Flange DN 100 PN 0 Form C, DIN 2501/ Enamelled 7) B 7 1 Flange DN 100 PN 0 Form F, DIN 2501/316L B 7 2 Flange DN 100 PN 0 Form N, DIN 2501/316L B 7 3 Flange DN 100 PN 0 V13, DIN 2501/316L B 7 Flange DN 100 PN 6 Form E, DIN 2501/316L B 7 5 Flange DN 100 PN 100 Form E, DIN 2501/316L B 7 6 Flange DN 100 PN 100 Form L, DIN 2501/316L B 7 7 Flange DN 125 PN 16 Form F, DIN 2501/316L B 7 8 Flange DN 125 PN 0 Form C, DIN 2501/316L B 8 0 Flange DN 125 PN 0 Form N, DIN 2512/316L B 8 1 Flange DN 150 PN 16 Form C, DIN 2501/316L B 8 2 Flange DN 150 PN 16 Form C, DIN 2501/Hastelloy B 8 3 Flange DN 150 PN 16 Form C, DIN 2501/ECTFE 6) B 8 Flange DN 150 PN 16 Form C, DIN 2501/PFA 6) B 8 5 Flange DN 150 PN 16 Form D, DIN 2501/316L B 8 6 Flange DN 150 PN 0 Form C, DIN 2501/316L B 8 7 Flange DN 150 PN 0 Form C, DIN 2501/Hastelloy B 8 8 Flange DN 150 PN 0 Form F, DIN 2501/316L C 0 0 Flange DN 150 PN 0 Form N, DIN 2512/316L C 0 1 Flange DN 200 PN 10 Form C, DIN 2501/ECTFE 6) C 0 2 Flange DN 200 PN 16 Form C, DIN 2501/316L C 0 3 Flange DN 25 PN 0 Form B1, EN /316L C 0 Flange DN 25 PN 0 Form B1, EN /Hastelloy C 0 5 Flange DN 25 PN 0 Form B1, EN/316L/PFA 6) C 0 6 Flange DN 25 PN 0 Form B1, EN / Enamelled 7) C 0 7 Flange DN 25 PN 0 Form B2, EN /316L C 0 8 Flange DN 25 PN 0 Form F, EN /316L C 1 0 Flange DN 25 PN 63 Form B1, EN /316L C 1 1 Flange DN 25 PN 100 Form B2, EN /316L C 1 2 Flange DN 0 PN 0 Form B1, EN/316L C 1 3 Flange DN 0 PN 0 Form B1, EN /PFA 6) C 1 Flange DN 0 PN 0 Form B2, EN/316L C 1 5 Flange DN 50 PN 0 Form B1, EN/316L C 1 6 Flange DN 50 PN 0 Form B1, EN /Hastelloy C 1 7 Flange DN 50 PN 0 Form B1,EN / C 1 8 Monel ZB2977 Flange DN 50 PN 0 Form B1, EN /ECTFE 6) C 2 0 Flange DN 50 PN 0 Form B1, EN/316L/PFA 6) C 2 1 Flange DN 50 PN 0 Form B1, EN / Enamelled 7) C 2 2 Flange DN 50 PN 0 Form C, EN /316L C 2 3 Siemens FI 01 June 2015 /95

96 Point level measurement - Vibrating switches SITRANS LVL200 SITRANS LVL200, Rigid extension Compact vibrating level switch for material detection in liquid applications such as overflow, high, 7ML low, and demand applications, as well as pump protection. For use in SIL-2 and hazardous applications. Flange DN 50 PN 0 Form D, EN/316L C 2 Flange DN 50 PN 0 Form D, EN / C 2 5 Hastelloy Flange DN 50 PN 0 Form B2, EN /316L C 2 6 Flange DN 50 PN 0 Form E, EN /316L C 2 7 Flange DN 80 PN 0 Form B1, EN /316L C 2 8 Flange DN 80 PN 0 Form B1, EN /Hastelloy C 3 0 Flange DN 80 PN 0 Form B1, EN /ECTFE 6) C 3 1 Flange DN 80 PN 0 Form B1, EN / Enamelled 7) C 3 2 Flange DN 80 PN 0 Form B2, EN /316L C 3 3 Flange DN 100 PN 16 Form B1, EN /316L C 3 Flange DN 100 PN 16 Form B1, EN / C 3 5 Hastelloy Flange DN 100 PN 16 Form B1, EN / Enamelled 7) C 3 6 Flange DN 100 PN 0 Form B1, EN /316L C 3 7 Flange DN 100 PN 0 Form B1, EN / Enamelled 7) C 3 8 Flange DN 100 PN 0 Form C, EN /316L C 0 Flange DN 100 PN 63 Form B2, EN /316L C 1 Flange DN 150 PN 16 Form B1, EN /316L C 2 Flange DN 150 PN 16 Form B1, EN /PFA 6) C 3 Flange DN 150 PN 0 Form B1, EN /316L C Flange DN 150 PN 0 Form B1, EN / ECTFE 6) C 5 Flange DN 150 PN 0 Form B2, EN /316L C 6 Flange 1" 150 lb ANSI B16.5/316L C 7 Flange 1"150 lb RF, ANSI B16.5/Hastelloy C 8 Flange 1"150 lb RF, ANSI B16.5//Monel ZB2977 C 5 0 Flange 1" 150 lb RF, ANSI B16.5/ECTFE 6) C 5 1 Flange 1"150 lb RF, ANSI B16.5/PFA 6) C 5 2 Flange 1" 150 lb RF, ANSI B16.5/Enamelled 7) C 5 3 Flange 1" 300 lb RF, ANSI B16.5/316L C 5 Flange 1" 300 lb RF, ANSI B16.5/ECTFE 6) C 5 5 Flange 1" 600 lb RF, ANSI B16.5/316L C 5 6 Flange 1½" 150 lb RF, ANSI B16.5/316L C 5 7 Flange 1½" 150 lb RF, ANSI B16.5/Hastelloy C 5 8 Flange 1½" 150 lb RF, ANSI B16.5/ECTFE 6) C 6 0 Flange 1½" 150 lb RF, ANSI B16.5/PFA 6) C 6 1 Flange 1½" 150 lb RF, ANSI B16.5 Enamelled 7) C 6 2 Flange 1½" 150 lb FF, ANSI B16.5/ECTFE 6) C 6 3 Flange 1½" 300 lb RF, ANSI B16.5/316L C 6 Flange 1½" 300 lb RF, ANSI B16.5//Monel ZB2977 C 6 5 Flange 1½" 300 lb RF, ANSI B16.5/ECTFE 6) C 6 6 Flange 1½" 600 lb RF, ANSI B16.5/316L C 6 7 Flange 2" 150 lb RF, ANSI B16.5/316L C 6 8 Flange 2" 150 lb RF, ANSI B16.5/Hastelloy C 7 0 Flange 2" 150 lb RF, ANSI B16.5//Monel ZB2977 C 7 1 Flange 2" 150 lb RF, ANSI B16.5/ECTFE 6) C 7 2 Flange 2" 150 lb RF, ANSI B16.5/PFA 6) C 7 3 Flange 2" 150 lb RF, ANSI B16.5/Enamelled 7) C 7 Flange 2" 150 lb FF, ANSI B16.5/316L C 7 5 Flange 2" 150 lb FF, ANSI B16.5/ECTFE 6) C 7 6 Flange 2" 150 lb SG (small groove), C 7 7 ANSI B16.5/316L Flange 2" 300 lb RF, ANSI B16.5/316L C 7 8 Flange 2" 300 lb RF, ANSI B16.5/Hastelloy C 8 0 SITRANS LVL200, Rigid extension Compact vibrating level switch for material detection in liquid applications such as overflow, high, 7ML low, and demand applications, as well as pump protection. For use in SIL-2 and hazardous applications. Flange 2" 300 lb RF, ANSI B16.5/ECTFE 6) C 8 2 Flange 2" 300 lb RF, ANSI B16.5/PFA 6) C 8 3 Flange 2" 300 lb RF, ANSI B16.5 Enamelled 7) C 8 Flange 2" 300 lb RJF, ANSI B16.5/316L C 8 5 Flange 2" 300 lb ST, ANSI B16.5/316L C 8 6 Flange 2" 300 lb LG (large groove), C 8 7 ANSI B16.5/316L Flange 2" 300 lb LT, ANSI B16.5/316L C 8 8 Flange 2" 600 lb RF, ANSI B16.5/316L D 0 0 Flange 2" 600 lb RF, ANSI B16.5/Monel ZB2977 D 0 1 Flange 2" 600 lb RF, ANSI B16.5/ECTFE 6) D 0 2 Flange 2" 600 lb RJF, ANSI B16.5/316L D 0 3 Flange 2" 600 lb LG, ANSI B16.5/316L D 0 Flange 2" 900 lb RJF, ANSI B16.5/316L D 0 5 Flange 2½" 150 lb RF, ANSI B16.5/316L D 0 6 Flange 2½" 300 lb RF, ANSI B16.5/316L D 0 7 Flange 3" 150 lb RF, ANSI B16.5/316L D 0 8 Flange 3" 150 lb RF, ANSI B16.5/Hastelloy D 1 0 Flange 3" 150 lb RF, ANSI B16.5//Monel ZB2977 D 1 1 Flange 3" 150 lb RF, ANSI B16.5/ECTFE 6) D 1 2 Flange 3" 150 lb RF, ANSI B16.5/PFA 6) D 1 3 Flange 3" 150 lb RF, ANSI B16.5/Enamelled 7) D 1 Flange 3" 150 lb FF, ANSI B16.5/316L D 1 5 Flange 3" 150 lb FF, ANSI B16.5/ECTFE 6) D 1 6 Flange 3" 150 lb FF, ANSI B16.5/PFA 6) D 1 7 Flange 3" 300 lb RF, ANSI B16.5/316L D 1 8 Flange 3" 300 lb RF, ANSI B16.5/Hastelloy D 2 0 Flange 3" 300 lb RF, ANSI B16.5/ECTFE 6) D 2 1 Flange 3" 300 lb RF, ANSI B16.5/PFA 6) D 2 2 Flange 3" 300 lb RF, ANSI B16.5/Enamelled 7) D 2 3 Flange 3" 600 lb RF, ANSI B16.5/316L D 2 Flange 3½" 150 lb RF, ANSI B16.5/316L D 2 5 Flange 3½" 150 lb RF, ANSI B16.5/ECTFE 6) D 2 6 Flange " 150 lb RF, ANSI B16.5/316L D 2 7 Flange " 150 lb RF, ANSI B16.5/Hastelloy D 2 8 Flange " 150 lb RF, ANSI B16.5/ECTFE 6) D 3 0 Flange " 150 lb RF, ANSI B16.5/PFA 6) D 3 1 Flange " 150 lb RF, ANSI B16.5/Enamelled 7) D 3 2 Flange " 150 lb LT, ANSI B16.5/316L D 3 3 Flange " 300 lb RF, ANSI B16.5/316L D 3 Flange " 300 lb RF, ANSI B16.5/Hastelloy D 3 5 Flange " 300 lb RF, ANSI B16.5/ECTFE 6) D 3 6 Flange " 300 lb RJF, ANSI B16.5/316L D 3 7 Flange " 300 lb LG, ANSI B16.5/316L D 3 8 Flange " 300 lb LT, ANSI B16.5/316L D 0 Flange " 600 lb RF, ANSI B16.5/316L D 1 Flange " 600 lb RJF, ANSI B16.5/316L D 2 Flange 5" 150 lb RF, ANSI B16.5/316L D 3 Flange 6" 150 lb RF, ANSI B16.5/316L D Flange 6" 150 lb RF, ANSI B16.5/Hastelloy D 5 Flange 6" 150 lb RF, ANSI B16.5/ECTFE 6) D 6 Flange 6" 150 lb RF, ANSI B16.5/PFA 6) D 7 Flange 6" 150 lb RJF, ANSI B16.5/316L D 8 Flange 6" 300 lb RF, ANSI B16.5/316L D 5 0 Flange 8" 150 lb RF, ANSI B16.5/316L D 5 1 Flange 8" 150 lb RF, ANSI B16.5/ECTFE 6) D 5 2 Flange 1" BS.10 Table E/316L D 5 3 /96 Siemens FI 01 June 2015

97 Point level measurement - Vibrating switches SITRANS LVL200 Flange 1" BS.10 Table E/PFA 6) D 5 Flange 1½" BS.10 Table E/316L D 5 5 Flange 3½" BS.10 Table E/316L D 5 6 Flange " BS.10 Table E/ECTFE 6) D 5 7 Flange DN 0 10K, JIS/316L D 5 8 Flange DN 50 10K, JIS/316L D 6 0 Flange DN 80 10K, JIS/316L D 6 1 Flange DN K, JIS/316L D 6 2 Adapter/Process temperature Without adapter/ C 1 With adapter/ C 8) 2 With adapter/ C 3 With gas-tight leadthrough/ C With gas-tight leadthrough/ C 5 Housing/ Cable entry SITRANS LVL200, Rigid extension Compact vibrating level switch for material detection in liquid applications such as overflow, high, low, and demand applications, as well as pump protection. For use in SIL-2 and hazardous applications. 7ML Aluminium IP66/IP67/M20x1.5 A Aluminium IP66/IP67/½" NPT B 316L stainless steel (electropolished) C IP66/IP67/M20X1.5 9)10) 316L stainless steel (electropolished) D IP66/IP67/½" NPT 9)10) NOTE: When selecting a Rigid Extension option, extension coating must match the process connection coating and the material and surface roughness type. Rigid Extension 316L mm A mm A mm A mm A mm A mm A mm A mm A 7 Rigid Extension ECTFE coated 6) mm B mm B mm B mm B mm B mm B 5 Rigid Extension PFA coated 6) mm C mm C mm C mm C mm C mm C 5 SITRANS LVL200, Rigid extension 7ML577- Compact vibrating level switch for material detection in liquid applications such as overflow, high, low, and demand applications, as well as pump protection. For use in SIL-2 and hazardous applications. Rigid Extension 316L Ra 0.8 μm mm D mm D mm D mm D mm D mm D mm D mm D 7 Rigid Extension 316L Ra 0.3 μm mm E mm E mm E mm E mm E mm E mm E mm E 7 Rigid Extension Enamelled version 7) mm F mm F mm F mm F mm F mm F 5 Rigid Extension Hastelloy mm G mm G mm G mm G mm G mm G mm G mm G 7 Rigid Extension Monel mm H mm H mm H mm H mm H mm H 5 1) Available with Adapter/Process temperature options 1, 3,, and 5 only 2) Available with Electronics option only 3) Available with Adapter/Process temperature options 1 and 3 only ) Extension length restricted to mm 5) Available with Housing/Cable entry option B only 6) Available with Adapter/Process temperature options 1 and only 7) Available with Adapter/Process temperature options 1, 2, and only 8) Available with enamelled Process connection and Extension options only 9) Available with Approval options A, B, C only 10) Not available with SIL/IEC61508 Certificate of conformity (SIL-2 min. and max. detection) Siemens FI 01 June 2015 /97

98 Point level measurement - Vibrating switches SITRANS LVL200 Order code Further designs Please add "-Z" to and specify Order code(s). Cleaning including Certificate W01 Spare Parts and Accessories Electronics module SITRANS LVL200 Relay Electronics module SITRANS LVL200 Contactless Lock fitting, unpressurized, G1" A/316L 7ML1830-1NC 7ML1930-6AA 7ML1930-1DQ (oil, grease and silicone free) Lock fitting, unpressurized, 1" NPT/316L 7ML1930-1DR Enter the total insertion length in plain text description, max. 000 mm (157.8 inch) Y01 Lock fitting, unpressurized, G1...1/2" A/316L Lock fitting, unpressurized, /2" NPT/316L 7ML1930-1DS 7ML1930-1DT Identification Label (measurement loop) stainless Y17 Lock fitting, bar, G1" A/316L 7ML1930-1DU steel: max. 16 characters add in plain text Lock fitting, bar, 1" NPT/316L 7ML1930-1DV Identification Label (measurement loop) Foil: max. 16 characters add in plain text Y18 Lock fitting, bar, G1... 1/2" A/316L Lock fitting, bar, /2" NPT/316L 7ML1930-1DW 7ML1930-1DX 3.1-Inspection Certificate for material (EN 1020 D07 Lock fitting, bar, G1" A/316L 7ML1930-1EA NACE MR 0175) 1) Lock fitting, bar, 1" NPT/316L 7ML1930-1EB 2.2-Factory certificate for material (EN 1020) 1) C15 Lock fitting, bar, G1... 1/2" A/316L 7ML1930-1EC Functional Safety (SIL 2). Device suitable for use in C20 Lock fitting, bar, /2" NPT/316L 7ML1930-1ED Dye penetration test certificate/instrument 1) C13 1) Listed Certificates are not available with all configurations, please contact factory for more information X-ray test certificate/instrument 1) C1 Positive material identification test certificate/instrument 1) C16 Roughness test certificate/instrument 1) C Inspection Certificate for instrument with test C25 data (EN 1020) Quality and test plan C26 Pressure test certificate/instrument 1) C31 Helium leak test certificate/instrument 1) C32 Ferrite measuring accuracy to DIN C certificate/instrument 1) Pressure test according to Norsok C certificate/instrument 1) Additional Operating Instructions LVL200 Extended (DPDT Relay) English 7ML1998-5KW01 French 7ML1998-5KW11 Spanish 7ML1998-5KW21 German 7ML1998-5KW31 LVL200 (Contactless electronic switch) English 7ML1998-5KV01 French 7ML1998-5KV11 Spanish 7ML1998-5KV21 German 7ML1998-5KV31 Electronics module LVL200 Relay English 7ML1998-5LS01 French 7ML1998-5LS11 Spanish 7ML1998-5LS21 German 7ML1998-5LS31 This device is shipped with the Siemens Milltronics manual DVD containing the Operating Instructions library. /98 Siemens FI 01 June 2015

99 Point level measurement - Vibrating switches SITRANS LVL200 Options LVL200 threaded welded socket Lock fitting G¾" A/316L G1" A/316L LVL200 extended 6 bar LVL200 extended 16 bar LVL200 extended unpressurized 32 (1.26) G¾" 39 (1.5) G1" 32 (1.26) 29.5 (1.16) 53 (2.09) 60 (2.36) SITRANS LVL200 welded socket and lock fitting, dimensions in mm (inch) Siemens FI 01 June 2015 /99

100 Point level measurement - Vibrating switches SITRANS LVL200 Characteristic curves Ambient/Process temperature Ambient temperature in C ( F) -50 ºC (-58 ºF) 70 ºC (158 ºF) 0 ºC (10 ºF) 0 ºC (32 ºF) 0 ºC (32 ºF) 50 ºC (122 ºF) 100 ºC (212 ºF) 150 ºC (302 ºF) Temperature range with temperature adapter 200 ºC (392 ºF) 250 ºC (82 ºF) -0 ºC (-0 ºF) Process temperature in C ( F) Process pressure with switch position 0.7 g/cm³ (mode switch) Process pressure in bar (psi g) 6 (928) 0 (580) 20 (290) -50 ºC (-58 ºF) -1 (-1.5) 0 ºC (32 ºF) 50 ºC (122 ºF) 100 ºC (212 ºF) 150 ºC (302 ºF) 200 ºC (392 ºF) 250 ºC (82 ºF) Process temperature in C ( F) Process pressure with switch position 0.5 g/cm³ (mode switch) Process pressure in bar (psi g) 6 (928) 0 (580) 20 (290) -50 ºC (-58 ºF) -1 (-1.5) 0 ºC (32 ºF) 50 ºC (122 ºF) 100 ºC (212 ºF) 150 ºC (302 ºF) 200 ºC (392 ºF) 250 ºC (82 ºF) Process temperature in C ( F) SITRANS LVL200 Process Pressure/Process Temperature/Ambient Temperature derating curves /100 Siemens FI 01 June 2015

101 Point level measurement - Vibrating switches SITRANS LVL200 Dimensional drawings SITRANS LVL200 (Standard) Stainless Steel enclosure ~ 59 (2.32 ) Ø 80 (3.15) Aluminium enclosure ~116 (.57) Ø8 (3.31) M20 x 1.5 M20 x 1,5 or ½" NPT 112 (.1) M20 x 1.5 or ½" NPT Threaded Tri-clamp Cone DN 25 Temperature adapter 18.5 (0.73) SW 32 (G ¾" A, ¾" NPT) SW 1 (G 1" A, 1" NPT) 66 (2.60) G ¾" A, ¾" NPT G 1" A, 1" NPT 53 (2.09) 178 (7.01) Bolting DN 0 Flange Gas-tight leadthrough Ø33.7 (1.33) 53 (2.09) 53 (2.09) 19 (0.75) 36 (1.2) 57 (2.2) 55 (2.17) 50 (1.97) 125 (.92) 3 (1.3) SITRANS LVL200 (Standard), dimensions in mm (inch) Siemens FI 01 June 2015 /101

102 Point level measurement - Vibrating switches SITRANS LVL200 SITRANS LVL200 (Extended) Sensor length (L) ~ 59 (2.32) Stainless Steel Enclosure Ø 80 (3.15) ~ 116 (.57) Aluminium Enclosure Ø 8 (3.31) 316L, Hastelloy C (2.610) mm ( inch) Hastelloy C (2.610) enamelled mm ( inch) 316L, ECTFE coated mm ( inch) 316L, PFA coated mm ( inch) M20 x1.5 M20x 1,5 or ½" NPT 112 (.1) M20x1.5 or ½" NPT 125 (.92) Threaded Tri-clamp Cone DN (0.73) 32 (G ¾" A, ¾" NPT) 1 (G 1" A, 1" NPT) G ¾" A, ¾" NPT G 1" A, 1" NPT 36 (1.2) 57 (2.2) L L L Temperature adapter Bolting DN 0 Flanged Gas-tight leadthrough 178 (7.01) 19 (0.75) 50 (1.97) 3 (1.3) L L SITRANS LVL200 (Extended), dimensions in mm (inch) /102 Siemens FI 01 June 2015

103 Point level measurement - Vibrating switches SITRANS LVL200 Schematics Relay (DPDT) 1 + L1 N V DC V AC Control lamp DIL switch for characteristics reversal DIL switch for sensitivity adjustment Ground terminal Relay output 5 Connection terminals Relay output Voltage supply Contactless L V 2 AC/DC C 1 2 I max 00 0 ma L N N A g/cm Control lamp B 0.7g/cm DIL switch for mode adjustment DIL switch for switching point adaptation Ground terminal Connection terminals AC DC L1 N + + Voltage supply NAMUR N 6 5 NAMUR (IEC ) Simul. max. min Control lamp DIL switch for characteristics reversal DIL switch for sensitivity adjustment Ground terminal Simulation key Connection terminals Amplifier according to NAMUR IEC , approx. 8.2 V SITRANS LVL200 connections Siemens FI 01 June 2015 /103

104 Point level measurement - Vibrating switches SITRANS LVS100 Overview Configuration Installation * Rigid extension with sliding sleeve Position tines vertically to avoid product build-up: use a 50 mm open-end wrench to turn the process connection until the tine orientation marking faces up or down. L SITRANS LVS100 is a vibrating point level switch for material detection in bulk solids. Benefits High resistance to mechanical forces Sliding sleeve options for adjustable insertion length and ease of cleaning Rotatable enclosure for ease of installation and wiring Suitable for point level detection of materials starting at a bulk density of 30 g/l (1.9 lb/ft 3 ) Customer desired extensions up to 000 mm (157.8 inch) O Protection in case of high material loading. Cable gland faces downward to avoid water penetration. Tine orientation marking facing sideways. Use angle mounting for flowing material only. If angle mounting is required with high material loading, customersupplied protection from falling material must be in place. Application SITRANS LVS100 detects high, low or demand levels of dry bulk solids in bins, silos or hoppers. SITRANS LVS100 has a compact design and can be top, side, or angle mounted. The vibrating fork design ensures the tines are kept clean. The unique design of the fork and crystal assembly eliminates false high level readings even if tines become damaged. A signal from the electronic circuit excites a crystal in the probe causing the fork to vibrate. If the fork is covered by material, the change in vibration is detected by the electronic circuitry which causes the relay to change state after a one second delay. When the fork is free from material pressure, full vibration resumes and the relay reverts to its normal condition. Key Applications: dry bulk solids in bins, silos, hoppers max. deviation from vertical O 5 5 > 5 SITRANS LVS100 installation, dimensions in mm (inch) * max. length L.0 m 1.2 m 0.6 m /10 Siemens FI 01 June 2015

105 Point level measurement - Vibrating switches SITRANS LVS100 Technical specifications Mode of Operation Measuring principle Input Measured variable Measuring frequency Output Relays Relay delay Signal delay Relay fail-safe Alarm output Vibrating point level switch High, low and demand 200 Hz DPDT relay From loss of vibration: approximately 1 second From resumption of vibration: approximately s Probe uncovered to covered: approximately 1 s Probe covered to uncovered: approximately s High or low, switch selectable Relay 8 A at 250 V AC, non-inductive Relay 5 A at 30 V DC, non-inductive High or low, switch selectable Sensitivity Rated operating conditions Installation conditions Location Indoor/outdoor Ambient conditions Ambient temperature C ( F) Installation category III Pollution degree 2 Medium conditions Process temperature C ( F) Max. threaded bushing temperature 60 C (10 F) Max. enclosure surface temperature 90 C (19 F) (Category 2D) Max. extension surface temperature 150 C (302 F) (Category 1D) Pressure (vessel) Max. 10 bar g (15 psi g) European Pressure Directive 97/23/EC: Category 1 Minimum material density Approx. 30 g/l (1.9 lb/ft 3 ) Design Material Enclosure Epoxy coated aluminum Process connection Thread 1¼" NPT [(Taper), ANSI/ASME B1.20.1], R 1½" [(BSPT), EN 10226] Thread R 1½" [(BSPT), EN 10226], ½" NPT [(Taper), ANSI/ASME B1.20.1], sliding sleeve [min. length 500 mm (19.69 inch)] Thread material: stainless steel 30 (1.301) or 316TI (1.571) depending on configuration Tine material Stainless steel 316TI (1.571) Degree of protection IP66/Type /NEMA Conduit entry 2 x M20x1.5 or 2 x ½" NPT Weight Standard version, no extensions: approx. 1.7 kg (3.7 lb) Power supply V AC, +10 %, Hz, 8 VA V DC, +10 %, 1.5 W Certificates and approvals CSA/FM General Purpose CE CSA/FM Dust Ignition Proof RCM ATEX II 1/2 D IECex Siemens FI 01 June 2015 /105

106 Point level measurement - Vibrating switches SITRANS LVS100 SITRANS LVS100, standard Vibrating point level switch for high or low level detection of bulk solids. Sensitivity > 30 g/l. 7ML A 0 Click on the for the online configuration in the PIA Life Cycle Portal. Input Voltage DPDT Relay V AC, V DC 1 DPDT Relay V AC, V DC 2 (stocked version) 1) Process temperature Up to 150 C (302 F) A Process connection Threaded R 1½" [(BSPT), EN 10226] A 1¼" NPT [(Taper), ANSI/ASME B1.20.1] B R 1½" [(BSPT), EN 10226] DIN 2999 thread, C sliding sleeve - min. length 500 mm (19.69 inch) 2) 1½" NPT [(Taper), ANSI/ASME B1.20.1], D sliding sleeve [min. length 500 mm (19.69 inch)] 2) Extension length Stainless steel 316TI (1.571) Standard length, 170 mm (6.69 inch) 1 1 Add Order code Y01 and plain text: "Insertion length... mm" Stainless steel 30 (1.301) mm ( inch) mm ( inch) mm ( inch) mm ( inch) mm ( inch) mm ( inch) mm ( inch) mm ( inch) 2 0 Approvals CSA/FM General Purpose, CE, RCM A CSA/FM Class II, Div. 1, Group E, F, G, Class III, B ATEX II 1/2 D, RCM IEC-Ex t IIIC Da/Db C 1) Only available with the following configurations 7ML5735-2AA11-0AA0 or 7ML5735-2AB11-0AA0 2) Not available with extension length options 11, 12 We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 9/5 in the appendix. Further Designs Please add "-Z" to and specify Order code(s). Total insertion length: Enter the total insertion length in plain text description, max. (50 mm increments) Signal bulb inserted in M20 cable gland 1) Operating Instructions Multi-language This device is shipped with the Siemens Milltronics manual DVD containing the ATEX Quick Start and Operating Instructions library. Spare Parts Replacement Electronics Module LVS100 DPDT Relay ( V AC, V DC) R 1½" [(BSPT), EN 10226] DIN 2999 thread, sliding sleeve 1½" NPT [(Taper), ANSI/ASME B1.20.1], sliding sleeve [min. length 500 mm (19.69 inch)] 1) Available only with approval CE Order code Y01 A20 7ML1998-5FT63 7ML1830-1NS 7ML1830-1NT 7ML1830-1NU Dimensional drawings SITRANS LVS100, dimensions in mm (inch) Schematics Tine orientation marking Threaded bushing [max. temp. 80 C (176 F)] Customer supplied process flange Tine Universal voltage (DPDT relay) Alarm output relay AC: SITRANS LVS100 connections 60 (2.36) 120 (.72) LED Zone 21 (cat. 2) Zone 20 (cat. 1) 125 (.92): Standard fork Terminal 1: L Terminal 2: N V AC, +10 %, Hz, 8 VA DC: Terminal 1: + Terminal 2: V DC, +10 %, 2 W 60 (2.36) 150 (5.91) 75 (2.95) ( ): Customer specified rigid FSH/FSL adjustment Sensitivity adjustment: B = factory setting, A = decreased /106 Siemens FI 01 June 2015

107 Point level measurement - Vibrating switches SITRANS LVS200 Overview SITRANS LVS200 is a vibrating point level switch for high, low, or demand level detection of bulk solids. Benefits High resistance to mechanical forces Strong vibration resistance to high bulk material loads Rotatable enclosure for convenient wiring Suitable for low density material: standard version, 20 g/l (1.3 lb/ft 3 ); liquid/solid interface version, 50 g/l (3 lb/ft 3 ) and low density option min. 5 g/l (0.3 lb/ft 3 ) Customer desired extensions up to mm (787 inch) Optional detection of solids within liquid Durable short fork option with 165 mm (6.5 inch) insertion length Application The standard LVS200 detects high, low, or demand levels of dry bulk solids in bins, silos, or hoppers. The liquid/solid interface version can also detect settled solids within liquids or solids within confined spaces such as feed pipes. It is designed to ignore liquids in order to detect the interface between a solid and a liquid. A pipe extension version is available with either the standard or liquid/solid interface electronics and fork, separated by a customer supplied 1 inch pipe. SITRANS LVS200 has an optional ma output for monitoring buildup on the fork to determine when preventative maintenance should be performed in sticky applications. The LVS200 has a compact design and can be top, side or angle mounted. The vibrating fork design ensures the tines are kept clean. The unique design of the fork and crystal assembly eliminates false high level readings even if tines become damaged. A signal from the electronic circuit excites a crystal in the probe causing the fork to vibrate. If the fork is covered by material, the change in vibration is detected by the electronic circuitry which causes the relay to change state after a one second delay. When the fork is free from material pressure, full vibration resumes and the relay reverts to its normal condition. Key Applications: dry bulk solids in bins, silos, hoppers or settled solids within liquids (interface version) Siemens FI 01 June 2015 /107

108 Point level measurement - Vibrating switches SITRANS LVS200 Technical specifications Mode of operation Measuring principle Input Measured variable Measuring frequency Standard Liquid/solid interface and short fork version Output PNP 2-wire without contact Vibrating point level switch High, low and demand 125 Hz 350 Hz Open collector: Permanent load max. 0. A, short-circuit and overload protected Turn-on voltage: max. 50 V (reverse protection) Load current: Min. 10 ma Max. 500 ma permanent Max. 2A < 200 ms Max. 5A < 50 ms Voltage drop on the electronic module: max. 7 V with closed electric circuit Cut-off current with open electric circuit: max. 5 ma Relays Version with 1 relay SPDT relay Version with 2 relays DPDT relay Relay delay From loss of vibration: approximately 1 second From resumption of vibration: approximately seconds Signal delay Probe uncovered to covered: approximately 1 second Probe covered to uncovered: approximately seconds Relay fail-safe High or low, switch selectable Alarm output Relay 8 A at 250 V AC, non-inductive Relay 5 A at 30 V DC, non-inductive ma output 8/16 ma or ma Resolution ma ± 0.1 ma Sensitivity High or low, switch selectable Rated operating conditions Installation conditions Location Indoor/outdoor Ambient conditions Ambient temperature C ( F) Installation category III Pollution degree 2 Medium conditions Process temperature All except CSA Class II, Group G: C ( F) CSA Class II, Group G: C ( F), CSA temperature code T3B Max. threaded bushing temperature 60 C (10 F) Max. enclosure surface temperature 90 C (19 F) (Category 2D) Max. extension surface temperature 150 C (302 F) (Category 1D) Pressure (vessel) Max. 10 bar g (15 psi g) European Pressure Directive 97/23/EC: Category 1 Minimum material density Standard version: approx. 20 g/l (1.2 lb/ft 3 ) Liquid/solid interface version: approx. 50 g/l (3 lb/ft 3 ) Optional low density version: approx. 5 g/l (0.3 lb/ft 3 ) Design Material Enclosure Epoxy coated aluminum Process connection Thread 1½" NPT [(Taper), ANSI/ASME B1.20.1], R ½" [(BSPT), EN 10226] and flange options Optional sliding bushing with 2" NPT [(Taper), ANSI/ASME B1.20.1] or BSP thread Thread material: stainless steel 303 (1.301) Tine material Stainless steel 316TI (1.571), PTFE-coated tines are available upon special request Degree of protection IP65/Type /NEMA Conduit entry 2 x M20x1.5 or 2 x ½" NPT Weight Standard version, no extensions: approx. 2.0 kg (. lb) Solids/liquids version, no extensions: approx. 1.9 kg (.2 lb) Power supply V AC, +10 %, Hz, 8 VA V DC, +10 %, 1.5 W Certificates and approvals CSA/FM General Purpose CE CSA/FM Dust Ignition Proof RCM ATEX II 1/2 D CSA/FM IS Class I, II, III Div. 1, Groups A, B, C, D, E, F, G, FM Class 1, Aex ia IIC, CSA Class 1, Ex ia IIC, available only with power supply option 5 and 6 ATEX II 1G and 1/2 G Eex ia IIC; ATEX II 1D and 1/2 D, available only with power supply option 5 /108 Siemens FI 01 June 2015

109 Point level measurement - Vibrating switches SITRANS LVS200 SITRANS LVS200, standard SITRANS LVS200 is a vibrating point level switch for high, low, or demand level detection of bulk 7ML A 0 solids. Click on the for the online configuration in the PIA Life Cycle Portal. Power supply V AC, V DC, one relay output 1 (SPDT) 1) V AC, V DC, two relay outputs 2 (DPDT) 1) V DC PNP 1) V AC/DC without contact, 2-wire loop powered 1) V DC (requires NAMUR switch amplifier) 5 NAMUR IEC , 2-wire 2) 8/16 ma or ma; V DC, 2-wire 3) V AC, V DC, one relay output } 7 (SPDT) basic version )5) Process temperature Without temperature isolator } A With temperature isolator B Separated enclosure - cable length 1.5 m (.92 ft) [max. temperature process 150 C (302 F)/ max. temperature electronics 60 C (10 F)] C Separated enclosure - cable length.0 m (13.12 ft) D [max. temperature process150 C (302 F)/ max. temperature electronics 60 C (10 F)] Process connection Threaded R 1½" [(BSPT), EN 10226] } A 1½" NPT [(Taper), ANSI/ASME B1.20.1] } B G 2" [(BSPP), EN ISO 228-1], sliding sleeve C [min. length 500 mm (19.69 inch)] 6) 2" NPT [(Taper), ANSI/ASME B1.20.1], D sliding sleeve [min. length 500 mm (19.69 inch)] 6) Flanged DN 100 PN 6, EN ) E DN 100 PN 16, EN F 2" ASME 150 lb B16.5 G 3" ASME 150 lb B16.5 H " ASME 150 lb B16.5 J 2" Tri-clamp (DN 50) ISO 2852 K Extension length Stainless steel 30 (1.301) Standard length, 235 mm (9.25 inch) } 1 1 Add Order code Y01 and plain text: "Insertion length... mm" mm ( inch) mm ( inch) mm ( inch) mm ( inch) mm ( inch) mm ( inch) mm ( inch) mm ( inch) mm ( inch) mm ( inch) mm ( inch) mm ( inch) mm ( inch) mm ( inch) mm ( inch) 2 8 SITRANS LVS200, standard 7ML5731- SITRANS LVS200 is a vibrating point level switch for high, low, or demand level detection of bulk A 0 solids. Stainless steel 316L (1.0) Standard length, 235 mm (9.25 inch) 3 1 Add Order code Y01 and plain text: "Insertion length... mm" mm ( inch) mm ( inch) mm ( inch) mm ( inch) mm ( inch) mm ( inch) mm ( inch) mm ( inch) mm ( inch) mm ( inch) mm ( inch) mm ( inch) mm ( inch) mm ( inch) mm ( inch) 8 Material process connection/extension Stainless steel threads 30 (1.301), } 1 flanges 321 (1.51), Tri-clamp 30 (1.301) 8) Stainless steel 316L (1.0) 9) 2 Approvals CSA/FM Dust Ignition Proof, RCM } A ATEX II 1/2 D, RCM } B CSA/FM General Purpose, RCM C CE, RCM D CSA/FM IS Class I, II, III Div. 1, Groups A, B, C, D, E E, F, G, FM Class 1, Aex ia IIC, CSA Class 1, Ex ia IIC, RCM ATEX II 1G and 1/2G Eex ia IIC; ATEX II 1D and F 1/2D, RCM IEC-Ex t IIIC Da/Db G 1) Available with Approval options A... D, G only 2) Available with Approval options D, E, F only 3) Available with Approval options B, D, G only ) Available with configurations 7ML5731-7AA11-1BA0 or 7ML5731-7AB11-1AA0 only 5) Basic version is cost effective and offers fast delivery 6) Not available with extension length options 11, 12, 31, 32 7) Max. 6 bar (87 psi) 8) Available with option extension length ) Available with option extension length 31 8 We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 9/5 in the appendix. } Available ex stock. For details see page 9/5 in the appendix. Siemens FI 01 June 2015 /109

110 Point level measurement - Vibrating switches SITRANS LVS200 Further Designs Please add "-Z" to and specify Order code(s). Total insertion length: Enter the total insertion length in plain text description, max. 000 mm (157.8 inch) Stainless steel tag [100 x 5 mm (3.9 x 1.77 inch)]: Measuring-point number/identification (max. 27 characters); specify in plain text Enhanced sensitivity > 5 g/l via electronics and increased insertion length of 25 mm (0.98 inch) 3) Enhanced sensitivity < 5 g/l via electronics, increased insertion length of 25 mm (0.98 inch), and increased aluminum fork width 1)3) Signal bulb inserted in M20 cable gland 2) NAMUR 8/16 ma switch amplifiers available, contact factory for pricing Operating Instructions Multi-language This device is shipped with the Siemens Milltronics manual DVD containing the ATEX Quick Start and Operating Instructions library. Spare Parts Replacement Electronics Module (125 Hz) [ V AC, V DC, one relay output (SPDT)] Replacement Electronics Module (125 Hz) [ V AC, V DC, two relay output (DPDT)] Sliding sleeve, 2" BSP (ISO 228) Sliding sleeve, 2" NPT (ASME B1.20.1) Namur Isolator switch amplifier relay output KFD2-SR2-Ex1.W Available ex stock For details see page 9/5 in the appendix. SITRANS LVS200, standard, power supply 7, process temperature A, process connection A, extension length 11, material process connection/ extension 1, and approval B SITRANS LVS200, standard, power supply 7, process temperature A, process connection B, extension length 11, material process connection/ extension 1, and approval A Order code Y01 Y1 K05 G01 A20 1) Available only with power supply 1 and Approval C, D and with Process connection flange E... J 2) Available with Approval option D only 3) K05 and G01 are not available together 7ML1998-5FT63 7ML1830-1KL A5E ML1830-1JM 7ML1830-1JN A5E ML5731-7AA11-1BA0 7ML5731-7AB11-1AA0 SITRANS LVS200, short fork for liquids/ solids interface Vibrating point level switch for solids or solids 7ML A 0 within liquid interface applications, and high load applications with short insertion requirements Click on the for the online configuration in the PIA Life Cycle Portal. Power supply V AC, V DC, one relay output 1 (SPDT) V AC, V DC, two relay outputs 2 (DPDT) V DC PNP V AC/DC without contact, 2-wire loop powered 8/16 ma or ma; V DC, 2-wire 1) 5 Process temperature Without temperature isolator A With temperature isolator B Separated enclosure - cable length 1.5 m (.92 ft) C [max. temperature process 150 C (302 F)/ max. temperature electronics 60 C (10 F)] Separated enclosure - cable length.0 m (13.12 ft) D [max. temperature process 150 C (302 F)/ max. temperature electronics 60 C (10 F)] Process connection Threaded R 1½" [(BSPT), EN 10226] A 1½" NPT [(Taper), ANSI/ASME B1.20.1] B G 2" [(BSPP), EN ISO 228-1], sliding sleeve C [min. length 500 mm (19.69 inch)] 2) 2" NPT [(Taper), ANSI/ASME B1.20.1], D sliding sleeve [min. length 500 mm (19.69 inch)] 2) Flanged DN 100 PN 6, EN ) E DN 100 PN 16, EN F 2" ASME 150 lb B16.5 G 3" ASME 150 lb B16.5 H " ASME 150 lb B16.5 J 2" Tri-clamp (DN 50) ISO 2852 K Extension length Stainless steel 30 (1.301) Standard length, 165 mm (6.50 inch) 1 1 Add Order code Y01 and plain text: "Insertion length... mm" mm ( inch) mm ( inch) mm ( inch) mm ( inch) mm ( inch) mm ( inch) mm ( inch) mm ( inch) mm ( inch) mm ( inch) mm ( inch) mm ( inch) mm ( inch) mm ( inch) mm ( inch) 2 8 /110 Siemens FI 01 June 2015

111 Point level measurement - Vibrating switches SITRANS LVS200 SITRANS LVS200, short fork for liquids/ 7ML5732- solids interface Vibrating point level switch for solids or solids A 0 within liquid interface applications, and high load applications with short insertion requirements Stainless steel 316L (1.0) Standard length, 165 mm (6.50 inch) 3 1 Add Order code Y01 and plain text: "Insertion length... mm" mm ( inch) mm ( inch) mm ( inch) mm ( inch) mm ( inch) mm ( inch) mm ( inch) mm ( inch) mm ( inch) mm ( inch) mm ( inch) mm ( inch) mm ( inch) mm ( inch) mm ( inch) 8 Material process connection/extension Stainless steel threads 30 (1.301), 1 flanges 321(1.51), Tri-clamp 30 (1.301) ) Stainless steel 316L (1.0) 5) 2 Approvals CSA/FM Dust Ignition Proof, RCM A ATEX II 1/2 D, RCM B CSA/FM General Purpose, RCM C CE, RCM D IEC-Ex t IIIC Da/Db E Further Designs Please add "-Z" to and specify Order code(s). Total insertion length: Enter the total insertion length in plain text description, max. 000 mm (17.8 inch) Stainless steel tag [100 x 5 mm (3.9 x 1.77 inch)]: Measuring-point number/identification (max. 27 characters); specify in plain text Signal bulb inserted in M20 cable gland 1) Adjustable sensitivity (by potentiometer) for solids/ liquids interface detection 1)2) Operating Instructions Multi-language This device is shipped with the Siemens Milltronics manual DVD containing the ATEX Quick Start and Operating Instructions library. Spare Parts Replacement Electronics Module (350 Hz) [ V AC, V DC, one relay output (SPDT)] Sliding sleeve, 2" BSP (ISO 228) Sliding sleeve, 2" NPT (ASME B1.20.1) 1) Available with Approval option D only 2) Available with power supply option 1 only Order code Y01 Y1 A20 G02 7ML1998-5FT63 7ML1830-1KM 7ML1830-1JM 7ML1830-1JN 1) Available with Approval option B, D, E only 2) Not available with extension length options 11,12, 31, 32 3) Max. 6 bar (87psi) ) Available with option extension length ) Available with option extension length 31 8 We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 9/5 in the appendix. Siemens FI 01 June 2015 /111

112 Point level measurement - Vibrating switches SITRANS LVS200 SITRANS LVS200, pipe extension 7ML5733- Vibrating point level switch for high or low levels of bulk solids - 77 A 0 Extended using 1" pipe extension (customer supplied) Click on the for the online configuration in the PIA Life Cycle Portal. Power supply V AC, V DC, one relay output 1 (SPDT) 1) V AC, V DC, two relay outputs 2 (DPDT) 1) V DC PNP 1) V AC/DC without contact, 2-wire loop powered 1) V DC (requires NAMUR switch amplifier) 5 NAMUR IEC , 2-wire 2) 8/16 ma or ma; V DC, 2-wire 3) 6 Process temperature Up to 150 C (302 F) A Process connection Threaded R 1½" [(BSPT), EN 10226] A 1½" NPT [(Taper), ANSI/ASME B1.20.1] B Flanged DN 100 PN 6, EN ) C DN 100 PN 16, EN D 2" ASME 150 lb B16.5 E 3" ASME 150 lb B16.5 F " ASME 150 lb B16.5 G 2" Tri-clamp (DN 50) ISO 2852 K Process connection material Stainless steel threads 30 (1.301), 1 flanges 321 (1.51), Tri-clamp 30 (1.301) Stainless steel 316L (1.0) 2 Extension length Customer supplied 1" pipe extension 1 Length: mm ( inch) Application type Dry bulk solids (125 Hz) 1 Liquids/solids interface (350 Hz) 2 Approvals CSA/FM Dust Ignition Proof, RCM A ATEX II 1/2 D, RCM B CSA/FM General Purpose, RCM C CE, RCM D CSA/FM IS Class I, II, III Div. 1, Groups A, B, C, D, E E, F, G, FM Class 1, Aex ia IIC, CSA Class 1, Ex ia IIC, RCM ATEX II 1G and 1/2G Eex ia IIC; ATEX II 1D and F 1/2D, RCM IEC-Ex t IIIC Da/Db H 1) Available with Approval options A, B, C, D, G only 2) Available with Approval options D, E and F only. Not available for application type 2 "Liquids/solids interface". 3) Available with Approval options B, D, G only ) Max. 6 bar (87 psi) Further Designs Please add "-Z" to and specify Order code(s). Total insertion length: Enter the total insertion length in plain text description, max mm (19.61 inch) Stainless steel tag [100 x 5 mm (3.9 x 1.77 inch)]: Measuring-point number/identification (max. 27 characters); specify in plain text Enhanced sensitivity > 5 g/l via electronics and increased insertion length of 25 mm (0.98 inch) 5) Enhanced sensitivity < 5 g/l via electronics, increased insertion length of 25 mm (0.98 inch) and increased aluminum fork width 1))5) Adjustable sensitivity (by potentiometer) for solids/ liquids interface detection 2)3)) Signal bulb inserted in M20 cable gland 2) Operating Instructions Multi-language This device is shipped with the Siemens Milltronics manual DVD containing the ATEX Quick Start and Operating Instructions library. Spare Parts Replacement Electronics Module (125 Hz) [ V AC, V DC, one relay output (SPDT)] Replacement Electronics Module (125 Hz) [ V AC, V DC, two relay output (DPDT)] Replacement Electronics Module (350 Hz) [ V AC, V DC, one relay output (SPDT)] Isolated switch amplifier relay output KFD2-SR2-Ex1.W Order code Y01 Y1 K05 G01 G02 A20 7ML1998-5FT63 7ML1830-1KL A5E ML1830-1KM A5E ) Available only with power supply 1 and Approvals C, D and with Process connection flange C G 2) Available with approval options D only 3) Available with power supply option 1 only and application type 2 ) Not available with option K05 5) Available with Application type 1 only /112 Siemens FI 01 June 2015

113 Point level measurement - Vibrating switches SITRANS LVS200 SITRANS LVS200, cable extended Vibrating point level switch for high or low level detection of bulk solids materials Click on the for the online configuration in the PIA Life Cycle Portal. 7ML A 0 Power supply V AC, V DC, one relay output (SPDT) 1) V AC, V DC, two relay outputs (DPDT) 1) V DC PNP 1) V AC/DC without contact, 2-wire loop powered 1) V DC (requires NAMUR switch amplifier) NAMUR IEC , 2-wire 2) 5 8/16 ma or ma; V DC, 2-wire 3) 6 Process temperature Up to 80 C (176 F) A Process connection Threaded R 1½" [(BSPT), EN 10226] (1.301/30) A 1½" NPT [(Taper), ANSI/ASME B1.20.1] B (1.301/30) Flanged DN 100 PN 6, EN (1.51/321) ) C DN 100 PN 16, EN (1.51/321) D 2" ASME 150 lb B16.5 (1.51/321) E 3" ASME 150 lb B16.5 (1.51/321) F " ASME 150 lb B16.5 (1.51/321) G Extension length mm ( inch) [max. length mm (787. inch), not with Power supply option 5 (max mm, inch)] Add Order code Y01 and plain text: "Insertion length... mm" mm ( inch) mm ( inch) mm ( inch) mm ( inch) mm ( inch) mm ( inch) mm ( inch) 5) mm ( inch) 5) mm ( inch) 5) mm ( inch) 5)6) mm ( inch) 5)6) mm ( inch) 5)6) mm ( inch) 5)6) mm ( inch) 5)6) mm ( inch) 5)6) mm ( inch) 5)6) mm ( inch) 5)6) mm ( inch) 5)6) mm ( inch) 5)6) 3 1 Application type Dry bulk solids (125 Hz) 1 Liquid/solids interface (350 Hz) 7) 2 SITRANS LVS200, cable extended Vibrating point level switch for high or low level detection of bulk solids materials Approvals CSA/FM Dust Ignition Proof, RCM ATEX II 1/2 D, RCM CSA/FM General Purpose, RCM CE, RCM CSA/FM IS Class I, II, III Div. 1, Groups A, B, C, D, E, F, G, FM Class 1, Aex ia IIC, CSA Class 1, Ex ia IIC, RCM ATEX II 1G and 1/2G Eex ia IIC; ATEX II 1D and 1/2D, RCM 6) IEC-Ex t IIIC Da/Db 1) Available with Approval options A, B, C, D, G only 2) Available with Approval option D, E and F only. Not available for application type 2 "Liquids/solids interface". 3) Available with Approval option D only ) Max. 6 bar (87 psi) 5) Not available with application type option 2 6) Not available with Power supply option 5 7) Cable length is limited to mm ( inch). Further Designs Please add "-Z" to and specify Order code(s). Enter the total insertion length in plain text description, max mm (787.0 inch) Stainless steel tag [100 x 5 mm (3.9 x 1.77 inch)]: Measuring-point number/identification (max. 27 characters); specify in plain text Enhanced sensitivity > 5 g/l via electronics and increased insertion length of 25 mm (0.98 inch) Enhanced sensitivity < 5 g/l via electronics and increased insertion length of 25 mm (0.98 inch) and increased aluminum fork width 1) Signal bulb inserted in M20 cable gland 2) Operating Instructions Multi-language This device is shipped with the Siemens Milltronics manual DVD containing the ATEX Quick Start and Operating Instructions library. Spare Parts Replacement Electronics Module (125 Hz) [ V AC, V DC, one relay output (SPDT)] Replacement Electronics Module (125 Hz) [ V AC, V DC, two relay output (DPDT)] Replacement Electronics Module (350 Hz) [ V AC, V DC, one relay output (SPDT)] Isolated switch amplifier relay output KFD2-SR2-Ex1.W 7ML A 0 Order code Y01 Y1 K05 G01 1) Available only with power supply 1 and Approvals C, D and with process connection flange C G 2) Available with Approval options C and D only A B C D E F G A20 7ML1998-5FT63 7ML1830-1KL A5E ML1830-1KM A5E Siemens FI 01 June 2015 /113

114 Point level measurement - Vibrating switches SITRANS LVS200 Dimensional drawings Tine orientation marking Threaded bushing [max. temp. 80 C (176 F)] A 120 (.72) A 150 (5.91) View A-A 60 (2.36) 75 (2.95) Thread length BSP: 20.5 (0.81) NPT: 2 (0.9) 2 (1.67) 155 (6.1) Optional sliding bushing* Customer supplied process flange 100 (3.9) Solids/liquids interface model ( ): Customer-specified rigid extension 100 (3.9) Solids/liquids interface model Tine 170 (6.69): Standard model 60 (2.36) 165 (6.5): Compact solids/ liquids interface model 230 (9.0): Compact standard version (1.67) Tine 195 (7.68) 170 (6.69): Standard model ( )** Notes: * The clamping screws of the sliding bushing must be tightened to 10 Nm. ** Cable version with liquids/solids interface model option length to mm ( inch) Cable version with NAMUR electronics length to mm (393.7 inch) tightened to 10 Nm. See drawing for pipe extended version details. (Pipe is customer supplied.) SITRANS LVS200, dimensions in mm (inch) /11 Siemens FI 01 June 2015

115 Point level measurement - Vibrating switches SITRANS LVS200 Schematics LED FSH/FSL adjustment Universal voltage (DPDT relay) 3-wire PNP Sensitivity adjustment (B=factory setting, A=decreased sensitivity) FSH FSL B A Alarm output relay Load L N V AC or +/ V DC Protective earth terminal PE + L - N AC Terminal 1: L, terminal 2: N V AC, +10 %, Hz, 18 VA DC Terminal 1: +, terminal 2: V DC, +10 %, 2 W Signal output PE + - DC Terminal 1: +, terminal 2: V DC, +10 %, 1.5 W 2-wire NAMUR IEC /16 ma or ma PE L - N AC Terminal 1: L, terminal 2: N V AC, +10 %, Hz, 1.5 VA DC Terminal 1: +, terminal 2: V DC, +10 %, 1 W PE L - N Approx V DC, intrinsically safe (IEC ) PE L - N DC terminal 1: +, terminal 2: V DC, + 0 % SITRANS LVS200 connections Siemens FI 01 June 2015 /115

116 Point level measurement - Rotation paddle switches SITRANS LPS200 Overview SITRANS LPS200 is a rotary paddle switch for point level and material detection in bulk solids. Benefits Proven paddle switch technology for bulk solids High integrity mechanical seal Optional switch selectable power supply Unique friction clutch mechanism prevents damage from falling material Rotatable enclosure for convenient wiring Optional paddles for use with low density materials Small paddle makes for simple installation through existing process connection High temperature model and optional extension kit available Optional fail-safe configuration detects loss of rotation Application The paddle switch technology detects full, empty, or demand conditions on materials such as grain, feed, cement, plastic granulate, and wood chips. The paddle switch can handle bulk densities as low as 15 g/l (2.19 lb/ft 3 ) with the optional rectangular vane or 100 g/l (6.25 lb/ft 3 ) with the standard measuring vane. A low revolution geared motor with slip clutch drives a rotating measuring vane which senses the presence of material at the mounted level of the LPS200. As material comes into contact with the rotating paddle, rotation stops, which changes the microswitch state. When the paddle is no longer covered by material, rotation resumes and the relay reverts to its normal condition. The LPS200 has a rugged design for use in harsh conditions in the solids industry. The sensitivity of the paddle can be adjusted for varying material properties like buildup on the vane. The LPS200 comes in a variety of configurations including compact, extended and cable extension. It is equipped with a standard vane which is effective in most applications, but can be configured with a hinged or rectangular vane for increased sensitivity for light materials. Key Applications: bulk solids such as grain, feed, cement, plastic granulate, wood chips Technical specifications Mode of operation Measuring principle Input Measured variable Output Output signal Alarm output Pickup delay Sensitivity Rotating point level switch High and low and demand Microswitch 5 A at 250 V AC, non inductive Microswitch SPDT contact A at 30 V DC, non-inductive Standard (1 rpm model): approx. 1.3 seconds Optional process applications (5 rpm model): approx seconds Adjustable via reset force of spring or geometry of measuring vane Rated operating conditions Installation conditions Location Indoor/outdoor Ambient conditions Ambient temperature C ( F) Installation category III Pollution degree 2 Medium conditions Bulk solids Temperature - Standard C ( F) - Optional C ( F) Higher temperature version available. Contact PVC for pricing. Pressure (vessel) - Standard Max. 0.5 bar g (7.25 psi g) - Optional Max. 10 bar g (15 psi g) Minimum material density - Standard measuring vane Can detect down to 100 g/l (6.25 lb/ft 3 ) - Optional measuring vane Can detect down to15 g/l (2.19 lb/ft 3 ) Design Material Enclosure Epoxy coated aluminum Process connection, measuring Stainless steel or aluminum shaft and vane Process connection Thread NPT, BSP, and flange options Degree of protection IP65/Type /NEMA Conduit entry 2 x M20x1.5 or 2 x ½" NPT Power supply Jumper selectable 115 V AC, ± 15 %, Hz, VA or 230 V AC, ± 15 %, 50 Hz, 6 VA, or 8 V AC, or 2 V AC or 2 V DC, ± 15 %, 2.5 W Universal voltage (DPDT replay) 2 V DC ± 15 % Hz, V, ± 10 %, max. 10 VA Certificates and approvals CSA/FM General Purpose CE CSA/FM Dust Ignition Proof ATEX II 1/2 D RCM IECex /116 Siemens FI 01 June 2015

117 Point level measurement - Rotation paddle switches SITRANS LPS200 Ord. code SITRANS LPS200, compact 7ML5725- Rotary paddle switch for level and material detection in bulk solids. Compact design for side or top mounted applications. Click on the for the online configuration in the PIA Life Cycle Portal. Process temperature Up to 80 C (176 F) 1 Up to 150 C (302 F) 2 Up to 250 C (82 F) 3 } 5 Up to 600 C (1 112 F) 1)2) Up to 80 C (176 F) basic version aluminum 3) Up to 80 C (176 F) basic version stainless steel ) } 6 Power supply 230 V AC, 1 rev/min. } A 230 V AC, 1 rev/min., fail-safe B 230 V AC, 5 rev/min. C 230 V AC, 5 rev/min., fail-safe D 115 V AC, 1 rev/min. } E 115 V AC, 1 rev/min., fail-safe F 115 V AC, 5 rev/min. G 115 V AC, 5 rev/min., fail-safe H 8 V AC, 1 rev/min. J 2 V AC, 1 rev/min. K 2 V DC, 1 rev/min. L 2 V DC, 1 rev/min., fail-safe M 2 V DC, 5 rev/min. N 2 V DC, 5 rev/min., fail-safe P Switch selectable 230 V AC/115 V } Q AC/2 V DC multi-voltage, 1 rev/min. Switch selectable 230 V AC/115 V AC/2 V DC multi-voltage, 5 rev/min. R 8 V AC, 1 rev/min., fail-safe Z J 1 A 8 V AC, 5 rev/min. Z J 1 B 8 V AC, 5 rev/min., fail-safe Z J 1 C 2 V AC, 1 rev/min., fail-safe Z J 1 D 2 V AC, 5 rev/min. Z J 1 E 2 V AC, 5 rev/min., fail-safe Z J 1 F Universal Voltage, 1 rev/min. 13) Z J 2 A Universal Voltage, 1 rev/min, fail-safe 13) Z J 2 B Universal Voltage, 5 rev/min. 13) Z J 2 C Universal Voltage, 5 rev/min, fail-safe 13) Z J 2 D Process connection Threaded G 1¼" [(BSPP), EN ISO 228-1] A G 1" [(BSPP), EN ISO 228-1] B G 1½" [(BSPP), EN ISO 228-1] } C 1" NPT [(Taper), ANSI/ASME B1.20.1] D 1¼" NPT [(Taper), ANSI/ASME B1.20.1] } E 1½" NPT [(Taper), ANSI/ASME B1.20.1] F Flanged DN 32 PN 6, EN ) G DN 100 PN 6, EN ) H DN 100 PN 16, EN J 2" ASME 150 lb B16.5 K 3" ASME 150 lb B16.5 L " ASME 150 lb B16.5 M 2" Tri-clamp (DN 50) ISO2852 6) N Ord. code SITRANS LPS200, compact 7ML5725- Rotary paddle switch for level and material detection in bulk solids. Compact design for side or top mounted applications Process pressure Up to 0.5 bar (7.25 psi) } 1 Up to 5 bar (72.5 psi) 2 Up to 10 bar (15 psi) 3 Process connection material Aluminum 7) } 1 Stainless steel, threads 303 (1.305), } 2 flanges 321 (1.51), Tri-clamp 30 (1.301) Stainless steel 316L (1.0) 8) 3 Extension length 100 mm (3.9 inch) 9) mm (5.91 inch) } mm (7.87 inch) mm (9.8 inch) 300 mm (11.81 inch) 5 Measuring vane Boot shaped, 35 x 106 mm (1.38 x.17 inch) 10) } A Hinged vane, 98 x 200 mm (3.86 x 7.87 inch) 10)11) B Boot shaped, 28 x 98 mm (1.10 x 3.86 inch) C Rectangular 50 x 150 mm (1.97 x 5.91 inch) 12) D Rectangular 50 x 250 mm (1.97 x 9.8 inch) 12) E Rectangular 98 x 150 mm (3.86 x 5.91 inch) 11)12) F Rectangular 98 x 250 mm (3.86 x 9.8 inch) 11)12) G Rectangular 50 x 98 mm (1.97 x 3.86 inch) 12) H Approvals CSA/FM Dust Ignition Proof, RCM } A ATEX II 1/2 D, RCM } B CSA/FM General Purpose, RCM } C CE, RCM } D IEC Ex ta/tb IIIC E 1) Available with approval option C and D only, up to 0.5 bar 2) Not available with process connection A,B, D, E and G 3) Only available with the following configurations 7ML5725-5AC11-2AD0 or 7ML5725-5EE11-2AC0 ) Only available with the following configurations 7ML5725-6QC12-2AB0 or 7ML5725-6QE12-2AA0 5) Available with process pressure 1 and 2 only 6) Available with process temperature 1 only 7) Available with process connections A... F only, process pressure option 1 and process temperature 1 and 5 only 8) Available with process connection C, F, H N and Measuring vane A 9) Available with measuring vane option A, C, D, E, H only 10) Add 16 mm (0.63 inch) to extension length 11) Available with extension lengths 2, 3,, 5 12) Available with process connections H M only 13) Available with approval option B, D, and E only We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 9/5 in the appendix. } Available ex stock. For details see page 9/5 in the appendix. Siemens FI 01 June 2015 /117

118 Point level measurement - Rotation paddle switches SITRANS LPS200 Further Designs Please add "-Z" to and specify Order code(s). Heating of enclosure 1)2) Signal bulb inserted in M20 cable gland 1) Food grade materials (in contact with process), according to 1935/200/EC, with FDA conform shaft sealing 3) Stainless steel tag [100 x 5 mm (3.9 x 1.77 inch)]: Measuring-point number/identification (max. 27 characters); specify in plain text Order code A35 A20 K01 Y1 Available ex stock For details see page 9/5 in the appendix. SITRANS LPS200, compact for up to 80 C (176 F), aluminum, with power supply A, process connection C, process pressure 1, process connection material 1, extension length 2, measuring vane A, and approval D SITRANS LPS200, compact for up to 80 C (176 F), aluminum, with power supply E, process connection E, process pressure 1, process connection material 1, extension length 2, measuring vane A, and approval C 7ML1830-1KG 7ML5725-5EE11-2AC0 Additional Operating Instructions Multi-language This device is shipped with the Siemens Milltronics manual DVD containing the ATEX Quick Start and Operating Instructions library. Spare Parts Motor gear /PLC, multi-voltage Replacement vane, boot shape, 35 x 106 mm (1.38 x.17 inch) Hinged vane, 98 x 200 mm (3.86 x 7.87 inch) Rigid extension kit (Includes spring coupling, rigid tube extension and required pins) A5E ML1830-1KG 7ML1830-1KH 7ML1830-1KJ SITRANS LPS200, compact for up to 80 C (176 F), stainless steel, with power supply Q, process connection C, process pressure 1, process connection material 2, extension length 2, measuring vane A, and approval B SITRANS LPS200, compact for up to 80 C (176 F), stainless steel, with power supply Q, process connection E, process pressure 1, process connection material 2, extension length 2, measuring vane A, and approval A 7ML5725-6QC12-2AB0 7ML5725-6QE12-2AA0 1) Available with approval option D only 2) Available with power supply options A,C, E, G, J, K, L, N, J1B, J1D, J1E, J2A, J2C only 3) Available up to 250 C (82 F). This option does not automatically implement a food conform design. Extension: 500, 00, 300 mm (19.7, 15.8, 11.8 inch) 7ML5711-0AA Extension: 1 000, 900, 800, 700, 600 mm (39., 35., 31.5, 27.6, 23.6 inch) 7ML5711-1AA Extension: 1 500, 1 00, 1 300, 1 200, mm (59.1, 55.1, 51.2, 7.2, 3.3 inch) 7ML5711-2AA Rope extension kit, 2 m (6.56 ft) 7ML1830-1KK /118 Siemens FI 01 June 2015

119 Point level measurement - Rotation paddle switches SITRANS LPS200 Ord. code SITRANS LPS200, shaft protected 7ML5726- Rotary paddle switch for level and material detection in bulk solids; ideal for heavy, sticky, or high impact applications. Designed with added protection tube for enhanced shaft protection and protection against build-up on shaft (sidewall build-up). Click on the for the online configuration in the PIA Life Cycle Portal. Process temperature Up to 80 C (176 F) 1 Up to 150 C (302 F) 2 Up to 250 C (82 F) 3 Up to 600 C (1 112 F) 1)2) Up to 80 C (176 F) basic version 3) } 5 Power supply 230 V AC, 1 rev/min. A 230 V AC, 1 rev/min., fail-safe B 230 V AC, 5 rev/min. C 230 V AC, 5 rev/min., fail-safe D 115 V AC, 1 rev/min. E 115 V AC, 1 rev/min., fail-safe F 115 V AC, 5 rev/min. G 115 V AC, 5 rev/min., fail-safe H 8 V AC, 1 rev/min. J 2 V AC, 1 rev/min. K 2 V DC, 1 rev/min. L 2 V DC, 1 rev/min., fail-safe M 2 V DC, 5 rev/min. N 2 V DC, 5 rev/min., fail-safe P Switch selectable 230 V AC/115 V AC/ } Q 2 V DC multi-voltage, 1 rev/min. Switch selectable 230 V AC/115 V AC/ 2 V DC multi-voltage, 5 rev/min. R 8 V AC, 1 rev/min., fail-safe Z J 1 A 8 V AC, 5 rev/min. Z J 1 B 8 V AC, 5 rev/min., fail-safe Z J 1 C 2 V AC, 1 rev/min., fail-safe Z J 1 D 2 V AC, 5 rev/min. Z J 1 E 2 V AC, 5 rev/min., fail-safe Z J 1 F Universal Voltage, 1 rev/min. 1) Z J 2 A Universal Voltage, 1 rev/min, fail-safe 1) Z J 2 B Universal Voltage, 5 rev/min. 1) Z J 2 C Universal Voltage, 5 rev/min, fail-safe 1) Z J 2 D Process connection Threaded G 1¼" [(BSPP), EN ISO 228-1] A G 1½" [(BSPP), EN ISO 228-1] } B 1¼" NPT [(Taper), ANSI/ASME B1.20.1] } C 1½" NPT [(Taper), ANSI/ASME B1.20.1] D Flanged DN 32 PN 6, EN ) E DN 100 PN 6, EN ) F DN 100 PN 16, EN G 2" ASME 150 lb B16.5 H 3" ASME 150 lb B16.5 J " ASME 150 lb B16.5 K 2" Tri-clamp (DN 50) ISO2852 5) L Ord. code SITRANS LPS200, shaft protected 7ML5726- Rotary paddle switch for level and material detection in bulk solids; ideal for heavy, sticky, or high impact applications. Designed with added protection tube for enhanced shaft protection and protection against build-up on shaft (sidewall build-up). Process pressure Up to 0.5 bar (7.25 psi) } 1 Up to 5 bar (72.5 psi) 2 Up to 10 bar (15 psi) 3 Process connection material Aluminum 6) 1 Stainless steel, threads 303 (1.305), } 2 flanges 321 (1.51), Tri-clamp 30 (1.301) Stainless steel 316L (1.0) 7) 3 Extension length 150 mm (5.91 inch) 8) mm (7.87 inch) } mm (9.8 inch) mm (11.81 inch) Extension material (protection tube) Aluminum 9) A Stainless steel 303 (1.305) } B Stainless steel 316L (1.0) 10) C Measuring vane Boot shaped 35 x 106 mm } A (1.38x.17inch) 11) Hinged vane, 98 x 200 mm B (3.86 x 7.87 inch) 11)12) Rectangular 50 x 150 mm D (1.97x5.91inch) 13) Rectangular 50 x 250 mm E (1.97x9.8inch) 13) Rectangular 98 x 150 mm F (3.86x5.91inch) 12)13) Rectangular 98 x 250 mm G (3.86x9.8inch) 12)13) Rectangular 50 x 98 mm H (1.97 x 3.86 inch) 13) Approvals CSA/FM Dust Ignition Proof, RCM } 1 ATEX II 1/2 D, RCM } 2 CSA/FM General Purpose, RCM 3 CE, RCM IEC Ex ta/tb IIIC 5 1) Available with approval option 3 and only and up to max 0.5 bar 2) Not available with process connections A, C, E 3) Only available with the following configurations 7ML5726-5QB12-2BA2 or 7ML5726-5QC12-2BA1 ) Available with process pressure 1 and 2 only 5) Available with process temperature 1 only 6) Available with process connections A... E only, available with process pressure option 1 only, and process temperature 1 only 7) Extension and vane will also change to 316L, only for process connection B, D, F L and vane A 8) Available with measuring vane options A, D, E, H only 9) Available with process pressure 1 and process temperature 1 only 10) Available with process connections B, D, F L and vane A 11) Add 16 mm (0.63 inch) to extension length 12) Available with extension length options 2 only 13) Available with process connections F, G, H, J, K only 1) Available with approval options 2, and 5 only We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 9/5 in the appendix. } Available ex stock. For details see page 9/5 in the appendix. Siemens FI 01 June 2015 /119

120 Point level measurement - Rotation paddle switches SITRANS LPS200 Further Designs Please add "-Z" to and specify Order code(s). Heating of enclosure 1)2) Signal bulb inserted in M20 cable gland 1) Food grade materials (in contact with process), according to 1935/200/EC, with FDA conform shaft sealing 3) Stainless steel tag [100 x 5 mm (3.9 x 1.77 inch)]: Measuring-point number/identification (max. 27 characters); specify in plain text Additional Operating Instructions Multi-language This device is shipped with the Siemens Milltronics manual DVD containing the ATEX Quick Start and Operating Instructions library. Spare Parts Motor gear /PLC, multi-voltage Replacement vane, boot shape, 35 x 106 mm (1.38 x.17 inch) Hinged vane, 98 x 200 mm (3.86 x 7.87 inch) Available ex stock For details see page 9/5 in the appendix. SITRANS LPS200, extended for up to 80 C (176 F), power supply Q, process connection B, process pressure 1, process connection material 2, extension length 2, extension material B, measuring vane A, and approval 2 SITRANS LPS200, extended for up to 80 C (176 F), power supply Q, process connection C, process pressure 1, process connection material 2, extension length 2, extension material B, measuring vane A, and approval 1 Order code A35 A20 K01 Y1 A5E ML1830-1KG 7ML1830-1KH 7ML1830-1KJ 7ML5726-5QB12-2BA2 7ML5726-5QC12-2BA1 1) Available with approval option only 2) Available with power supply options A,C, E, G, J, K, L, N, J1B, J1D, J1E, J2A, J2C only 3) Available up to 250 C (82 F). This option does not automatically implement a food conform design. Ord. code SITRANS LPS200, cable extension 7ML5727- Rotary paddle switch for level and material detection in bulk solids Cable extension for increased length in top-mounted applications Click on the for the online configuration in the PIA Life Cycle Portal. Process temperature Up to 80 C (176 F) 1 Up to 150 C (302 F) 2 Up to 250 C (82 F) 3 Up to 600 C (1 112 F) 1)2) Up to 80 C (176 F) basic version 3) 5 Power supply 230 V AC, 1 rev/min. A 230 V AC, 1 rev/min., fail-safe B 230 V AC, 5 rev/min. C 230 V AC, 5 rev/min., fail-safe D 115 V AC, 1 rev/min. E 115 V AC, 1 rev/min., fail-safe F 115 V AC, 5 rev/min. G 115 V AC, 5 rev/min., fail-safe H 8 V AC, 1 rev/min. J 2 V AC, 1 rev/min. K 2 V DC, 1 rev/min. L 2 V DC, 1 rev/min., fail-safe M 2 V DC, 5 rev/min. N 2 V DC, 5 rev/min., fail-safe P Switch selectable 230 V AC/115 V AC/ Q 2 V DC multi-voltage, 1 rev/min. Switch selectable 230 V AC/115 V AC/ 2 V DC multi-voltage, 5 rev/min. R 8 V AC, 1 rev/min., fail-safe Z J 1 A 8 V AC, 5 rev/min. Z J 1 B 8 V AC, 5 rev/min., fail-safe Z J 1 C 2 V AC, 1 rev/min., fail-safe Z J 1 D 2 V AC, 5 rev/min. Z J 1 E 2 V AC, 5 rev/min., fail-safe Z J 1 F Universal Voltage, 1 rev/min. 9) Z J 2 A Universal Voltage, 1 rev/min, fail-safe 9) Z J 2 B Universal Voltage, 5 rev/min. 9) Z J 2 C Universal Voltage, 5 rev/min, fail-safe 9) Z J 2 D Process connection Threaded G 1¼" [(BSPP), EN ISO 228-1] A G 1½" [(BSPP), EN ISO 228-1] B 1¼" NPT [(Taper), ANSI/ASME B1.20.1] C 1½" NPT [(Taper), ANSI/ASME B1.20.1] D Flanged DN 32 PN 6, EN ) E DN 100 PN 6, EN ) F DN 100 PN 16, EN G 2" ASME 150 lb B16.5 H 3" ASME 150 lb B16.5 J " ASME 150 lb B16.5 K /120 Siemens FI 01 June 2015

121 Point level measurement - Rotation paddle switches SITRANS LPS200 Measuring vane Boot shaped, 35 x 106 mm A (1.38 x.17 inch) 6) Hinged vane, 98 x 200 mm B (3.86 x 7.87 inch) 6) Boot shaped, 28 x 98 mm C (1.10 x 3.86 inch) 7) Rectangular 50 x 150 mm D (1.97 x 5.91 inch) 7) Rectangular 50 x 250 mm E (1.97 x 9.8 inch) 7) Rectangular 98 x 150 mm F (3.86 x 5.91 inch) 7) Rectangular 50 x 98 mm G (1.97 x 3.86 inch) 7) Approvals CSA/FM Dust Ignition Proof, RCM A ATEX II 1/2 D, RCM B CSA/FM General Purpose, RCM C CE, RCM D IEC Ex ta/tb IIIC E 1) Available with approval option C and D up to max. 0.5 bar 2) Not available with process connections A, C, E 3) Only available with the following configurations 7ML5727-5QC12-0AA0 or 7ML5727-5QB12-0AB0 ) Available with process pressure 1 and 2 only 5) Available with process connections A... E only, process pressure option 1 only and process temperature options 1 and 5 only 6) Add 16 mm (0.63 inch) to extension length 7) Available with process connections F K only 8) Not available with P01 and available with Approval D, mounting kit for rope extension included 9) Available with approval options B,D, and E only We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 9/5 in the appendix. Further Designs Please add "-Z" to and specify Order code(s). Total insertion length: Enter the total insertion length in plain text description, max mm ( inch) Stainless steel tag [100 x 5 mm (3.9 x 1.77 inch)]: Measuring-point number/identification (max. 27 characters); specify in plain text Reinforced cable (max. 28 kn pulling force) 1) Heating of enclosure 2)3) Signal bulb inserted in M20 cable gland 2) Food grade materials (in contact with process), according to 1935/200/EC, with FDA conform shaft sealing ) Additional Operating Instructions Multi-language This device is shipped with the Siemens Milltronics manual DVD containing the ATEX Quick Start and Operating Instructions library. Spare Parts Motor gear /PLC, multi-voltage Replacement vane, boot shape, 35 x 106 mm (1.38 x.17 inch) Hinged vane, 98 x 200 mm (3.86 x 7.87 inch) Available ex stock For details see page 9/5 in the appendix. SITRANS LPS200, cable extension for up to 80 C (176 F), power supply Q, process connection B, process pressure 1, process connection material 2, extension length 0, measuring vane A, and approval B SITRANS LPS200, cable extension for up to 80 C (176 F), power supply Q, process connection C, process pressure 1, process connection material 2, extension length 0, measuring vane A, and approval A Order code Y01 Y1 P01 A35 A20 K01 A5E ML1830-1KG 7ML1830-1KH 7ML1830-1KJ Ord. code SITRANS LPS200, cable extension 7ML5727- Rotary paddle switch for level and material detection in bulk solids Cable extension for increased length in top-mounted applications Process pressure Up to 0.5 bar (7.25 psi) 1 Up to 5 bar (72.5 psi) 2 Up to 10 bar (15 psi) 3 Process connection material Aluminum 5) 1 Stainless steel, threads 303 (1.305), 2 flanges 321 (1.51) Cable extension length Standard cable length, mm 0 (78.7 inch) Add Order code Y01 and plain text: "Insertion length... mm" mm ( inch) 1 Cable length mm 2 ( inch) Cable length mm 3 ( inch) Cable length mm ( inch) Cable length mm 5 ( inch) Cable length mm 6 ( inch) Cable length mm 7 ( inch) Cable length mm ( inch) 8 Without extension 8) 9 N 1 A 7ML5727-5QB12-0AB0 7ML5727-5QC12-0AA0 1) Available only for process temperature up to 80 C (176 F) and process connection material 2 2) Available with approval option D only 3) Available with power supply options A,C, E, G, J, K, L, N, J1B, J1D, J1E, J2A, J2C only ) Available up to 250 C (82 F). This option does not automatically implement a food conform design Siemens FI 01 June 2015 /121

122 Point level measurement - Rotation paddle switches SITRANS LPS200 Ord. code SITRANS LPS200, angled extension 7ML5728- Rotary paddle switch with robust design for level and material detection in bulk solids; ideal for heavy or sticky applications. Angled extension is designed to avoid falling material and rotates horizontally in side mount applications to continue working even with heavy build-up. Click on the for the online configuration in the PIA Life Cycle Portal. Process temperature Up to 80 C (176 F) 1 Up to 150 C (302 F) 2 Up to 250 C (82 F) 3 Power supply 230 V AC, 1 rev/min. A 230 V AC, 1 rev/min., fail-safe B 230 V AC, 5 rev/min. C 230 V AC, 5 rev/min., fail-safe D 115 V AC, 1 rev/min. E 115 V AC, 1 rev/min., fail-safe F 115 V AC, 5 rev/min. G 115 V AC, 5 rev/min., fail-safe H 8 V AC, 1 rev/min. J 2 V AC, 1 rev/min. K 2 V DC, 1 rev/min. L 2 V DC, 1 rev/min., fail-safe M 2 V DC, 5 rev/min. N 2 V DC, 5 rev/min., fail-safe P Switch selectable 230 V AC/115 V AC/2 V DC Q multi-voltage, 1 rev/min. Switch selectable 230 V AC/115 V AC/2 V DC R multi-voltage, 5 rev/min. 8 V AC, 1 rev/min., fail-safe Z J 1 A 8 V AC, 5 rev/min. Z J 1 B 8 V AC, 5 rev/min., fail-safe Z J 1 C 2 V AC, 1 rev/min., fail-safe Z J 1 D 2 V AC, 5 rev/min. Z J 1 E 2 V AC, 5 rev/min., fail-safe Z J 1 F Universal Voltage, 1 rev/min. 2) Z J 2 A Universal Voltage, 1 rev/min, fail-safe 2) Z J 2 B Universal Voltage, 5 rev/min. 2) Z J 2 C Universal Voltage, 5 rev/min, fail-safe 2) Z J 2 D Process connection Flanged DN 100 PN 6, EN ) A DN 100 PN 16, EN B " ASME 150 lb B16.5 C Process pressure Up to 0.5 bar (7.25 psi) 1 Up to 5 bar (72.5 psi) 2 Up to 10 bar (15 psi) 3 Process connection material Stainless steel 303/321 (1.305/1.51) 1 Extension length 125 mm (.92 inch) mm (5.91 inch) mm (7.87 inch) mm (9.8 inch) 300 mm (11.81 inch) 5 SITRANS LPS200, angled extension Rotary paddle switch with robust design for level and material detection in bulk solids; ideal for heavy or sticky applications. Angled extension is designed to avoid falling material and rotates horizontally in side mount applications to continue working even with heavy build-up. Measuring vane Rectangular vane, 50 x 98 mm (1.97 x 3.86 inch) Rectangular vane, 50 x 150 mm (1.97 x 5.91 inch) Rectangular vane, 50 x 250 mm (1.97 x 9.8 inch) Rectangular vane 98 x 150 mm (3.86 x 5.91 inch) Rectangular vane 98 x 250 mm (3.86 x 9.8 inch) Hinged vane, 98 x 200 mm (3.86 x 7.87 inch) Approvals CSA/FM Dust Ignition Proof, RCM ATEX II 1/2 D, RCM CSA/FM General Purpose, RCM CE, RCM IEC Ex ta/tb IIIC 1) Available with process pressure 1 and 2 only 2) Available with approval option B,D, and E only Further Designs Please add "-Z" to and specify Order code(s). Heating of enclosure 1)2) Signal bulb inserted in M20 cable gland 1) Food grade materials (in contact with process), according to 1935/200/EC, with FDA conform shaft sealing 3) Stainless steel tag [100 x 5 mm (3.9 x 1.77 inch)]: Measuring-point number/ identification (max. 27 characters); specify in plain text Additional Operating Instructions Multi-language This device is shipped with the Siemens Milltronics manual DVD containing the ATEX Quick Start and Operating Instructions library. Spare Parts Motor gear /PLC, multi-voltage Replacement vane, boot shape, 35 x 106 mm (1.38 x.17 inch) Hinged vane, 98 x 200 mm (3.86 x 7.87 inch) Ord. code 7ML ) Available with approval option D only 2) Available with power supply options A,C, E, G, J, K, L, N, J1B, J1D, J1E, J2A, J2C only 3) This option does not automatically implement a food conform design A B C D E F Order code A35 A20 K01 Y1 A B C D E A5E ML1830-1KG 7ML1830-1KH 7ML1830-1KJ /122 Siemens FI 01 June 2015

123 Point level measurement - Rotation paddle switches SITRANS LPS200 Ord. code SITRANS LPS200, rigid extension Rotary paddle switch for top mount point level and material detection in bulk solids 7ML Click on the for the online configuration in the PIA Life Cycle Portal. Process temperature Up to 80 C (176 F) 1 Up to 150 C (302 F) 2 Up to 250 C (82 F) 3 Up to 600 C (1 112 F) 1)2) Power supply 230 V AC, 1 rev/min. A 230 V AC, 1 rev/min., fail-safe B 230 V AC, 5 rev/min. C 230 V AC, 5 rev/min., fail-safe D 115 V AC, 1 rev/min. E 115 V AC, 1 rev/min., fail-safe F 115 V AC, 5 rev/min. G 115 V AC, 5 rev/min., fail-safe H 8 V AC, 1 rev/min. J 2 V AC, 1 rev/min. K 2 V DC, 1 rev/min. L 2 V DC, 1 rev/min., fail-safe M 2 V DC, 5 rev/min. N 2 V DC, 5 rev/min., fail-safe P Switch selectable 230 V AC/115 V Q AC/2 V DC multi-voltage, 1 rev/min. Switch selectable 230 V AC/115 V AC/2 V DC multi-voltage, 5 rev/min. R 8 V AC, 1 rev/min., fail-safe Z J 1 A 8 V AC, 5 rev/min. Z J 1 B 8 V AC, 5 rev/min., fail-safe Z J 1 C 2 V AC, 1 rev/min., fail-safe Z J 1 D 2 V AC, 5 rev/min. Z J 1 E 2 V AC, 5 rev/min., fail-safe Z J 1 F Universal Voltage, 1 rev/min. 1) Z J 2 A Universal Voltage, 1 rev/min, fail-safe 1) Z J 2 B Universal Voltage, 5 rev/min. 1) Z J 2 C Universal Voltage, 5 rev/min, fail-safe 1) Z J 2 D Process connection Threaded G 1¼" [(BSPP), EN ISO 228-1] A G 1½" [(BSPP), EN ISO 228-1] B 1¼" NPT [(Taper), ANSI/ASME B1.20.1] C 1½" NPT [(Taper), ANSI/ASME B1.20.1] D Flanged DN 32 PN 6, EN ) DN 100 PN 6, EN ) DN 100 PN 16, EN " ASME 150 lb B16.5 H 3" ASME 150 lb B16.5 J " ASME 150 lb B16.5 K 2" Tri-clamp 2 (DN 50) ISO2852 ) L E F G Ord. code SITRANS LPS200, rigid extension Rotary paddle switch for top mount point level and material detection in bulk solids 7ML5730- Process pressure Up to 0.5 bar (7.25 psi) 1 Up to 5 bar (72.5 psi) 2 Up to 10 bar (15 psi) 3 Process connection material Aluminum 5) 1 Stainless steel, threads 303 (1.305), flanges 321 (1.51), Tri-clamp 30 (1.301) 2 Stainless steel 316L (1.0) 6) Extension material (protection tube) Aluminum 7)8) 0 Stainless steel 303 (1.305) 9) 1 Stainless steel 316L (1.0) 10)11) 2 Extension length Aluminum mm ( inch) A mm ( inch) B mm ( inch) C mm ( inch) D mm ( inch) E mm ( inch) F mm ( inch) G mm ( inch) H mm ( inch) J mm ( inch) K mm ( inch) L mm ( inch) M mm ( inch) N mm ( inch) P mm ( inch) Q Stainless steel 303 (1.305) mm ( inch) R mm ( inch) S mm ( inch) T mm ( inch) U mm ( inch) V mm ( inch) W mm ( inch) X mm ( inch) Y Stainless steel 316L (1.0) mm ( inch) Z P 1 A mm ( inch) Z P 1 B mm ( inch) Z P 1 C mm ( inch) Z P 1 D mm ( inch) Z P 1 E mm ( inch) Z P 1 F mm ( inch) Z P 1 G mm ( inch) Z P 1 H Siemens FI 01 June 2015 /123

124 Point level measurement - Rotation paddle switches SITRANS LPS200 Ord. code SITRANS LPS200, rigid extension 7ML5730- Rotary paddle switch for top mount point level and material detection in bulk solids Measuring vane Boot shaped, 35 x 106 mm A (1.3 x.17 inch) 12) Hinged vane, 98 x 200 mm B (3.86 x 7.87 inch) 12) Rectangular 50 x 150 mm C (1.97 x 5.91 inch) 13) Rectangular 50 x 250 mm D (1.97 x 9.8 inch) 13) Rectangular 98 x 150 mm E (3.86 x 5.91 inch) 13) Rectangular 98 x 250 mm F (3.86 x 9.8 inch) 13) Rectangular 50 x 98 mm G (1.97 x 3.86 inch) 13) Approvals CSA/FM Dust Ignition Proof, RCM 1 ATEX II 1/2 D, RCM 2 CSA/FM General Purpose, RCM 3 CE, RCM IEC Ex ta/tb IIIC 5 1) Available with approval option 3 and, up to max 0.5 bar 2) Not available with process connection A, C, E 3) Available with process pressure 1 and 2 only ) Available with process temperature 1 only 5) Available with process connections A... E only, with process pressure option 1 only and process temperature 1 only 6) Available with process connection B, D, F L and measuring vane option A 7) Available with process pressure 1 and process temperature 1 only 8) Available with extension length options A Q only 9) Available with extension length options R Y only 10) Available with process connection B, D, F L and measuring vane A, process connection material 3. Available only with extension length options P1A P1H only 11) Only available with seal at tube end, option P06 P09 12) Add 16 mm (0.63 inch) to extension length 13) Available with process connections F, G, H, J, K only 1) Available with approval options 2, and 5 only We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 9/5 in the appendix Further Designs Please add "-Z" to and specify Order code(s). Total insertion length: Enter the total insertion length in plain text description, max. 000 mm (157.8 inch) Stainless steel tag [100 x 5 mm (3.9 x 1.77 inch)]: Measuring-point number/identification (max. 27 characters); specify in plain text Heating of enclosure 1)2) Signal bulb inserted in M20 cable gland 1) Food grade materials (in contact with process), according to 1935/200/EC, with FDA conform shaft sealing 3)) Seal at tube end for ingress protection and shaft stability Max. temperature 80 C (176 F) Max. temperature 150 C (302 F) Max. temperature 250 C (82 F) Max. temperature 600 C (1 112 F) Sliding sleeve (standard, max. pressure 0.5 bar) 1)5) Sliding sleeve (pressure tight, for over-pressure application starting from 1 bar max., dependent on pressure option ordered) 6) Additional Operating Instructions Multi-language This device is shipped with the Siemens Milltronics manual DVD containing the ATEX Quick Start and Operating Instructions library. Spare Parts Motor gear/plc, multi-voltage Replacement vane, boot shape, 35 x 106 mm (1.38 x.17 inch) Hinged vane, 98 x 200 mm (3.86 x 7.87 inch) Order code Y01 Y1 A35 A20 K01 P06 P07 P08 P09 P12 P13 A5E ML1830-1KG 7ML1830-1KH 7ML1830-1KJ 1) Available with approval option only 2) 15) Available with power supply options A,C, E, G, J, K, L, N, J1B, J1D, J1E, J2A, J2C only 3) Available when ordered with ingress protection seal P06 P09 only ) Available up to 250 C (82 F). This option does not automatically implement a food conform design 5) Available with process pressure 1 only 6) Available up to 250 C (82 F) /12 Siemens FI 01 June 2015

125 Point level measurement - Rotation paddle switches SITRANS LPS200 Dimensional drawings Standard model: compact version Conduit connection M20 or ½" NPT Ambient temperature C ( F) Zone 21 (Cat. 2) Zone 20 (Cat. 1) Process temperature C ( F) Measuring vanes 35 (1.38) A Thread length BSP: 20.5 (0.81) NPT: 2 (0.9) Standard 106 (.17) Rectangular B 60 (2.36) Hinged Fold together to lead into mounting hole 120 (.72) Measuring vane Rectangular vane options A 50 (1.97) 50 (1.97) 50 (1.97) 98 (3.86) 98 (3.86) 60 (2.36) 75 (2.95) 123 (.8) Optional process flange 1. For 35 x 106 mm boot shaped and 98 x 200 mm hinged measuring vanes, add 16 mm to extension length. 2. For use with all approval options except CSA class II. See manual for more details. Notes For heavy material, only top mounting of paddle switch is recommended. Compact LPS200 is recommended for side mounting on bins for low or intermediate material levels. 1) L B 98 (3.86) 150 (5.90) 250 (9.8) 150 (5.90) 250 (9.8) Min. 37 (1.6) High temperature model: compact version Shaft protected option Vane Boot shaped 35 x 106 mm Boot shaped 28 x 98 mm Rectangular 50 x 98 mm Rectangular 50 x 150 mm Rectangular 50 x 250 mm Rectangular 98 x 150 mm Rectangular 98 x 250 mm Hinged 98 x 200 mm Thread length BSP: 20.5 (0.81) NPT: 2 (0.9) Ambient temperature C ( F) Zone 21 (Cat. 2) Zone 20 (Cat. 1) Process temperature 2) C ( F) 1) L 210 (8.27) Light 200 g/l (12.5 lb/ft³) 300 g/l (18.7 lb/ft³) 300 g/l (18.7 lb/ft³) 80 g/l (5.0 lb/ft³) 30 g/l (1.9 lb/ft³) 30 g/l (1.9 lb/ft³) 20 g/l (1.2 lb/ft³) 70 g/l (. lb/ft³) Angle option 65 (2.56) ( ) Completely covered with material Spring adjustment Rope fixing Central (factory setting) 300 g/l (18.7 lb/ft³) 500 g/l (31.2 lb/ft³) 500 g/l (31.2 lb/ft³) 120 g/l (7.5 lb/ft³) 50 g/l (3.1 lb/ft³) 50 g/l (3.1 lb/ft³) 30 g/l (1.9 lb/ft³) 100 g/l (6.2 lb/ft³) A 1) L Process temperature 150/250 C (302/82 ºF) L= Length 100 (3.9) 150 (5.91) 200 (7.87) 250 (9.8) 300 (11.81) Rope option (78.7) standard; Can be shortened by the customer; total length available (393.7) Covered up to 10 cm (3.93 inch) with material Spring adjustment Light 100 g/l (6.2 lb/ft³) 150 g/l (9. lb/ft³) 150 g/l (9. lb/ft³) 0 g/l (2.5 lb/ft³) 15 g/l (0.9 lb/ft³) 15 g/l (0.9 lb/ft³) 15 g/l (0.9 lb/ft³) 35 g/l (2.2 lb/ft³) 600 C (1 112 ºF) A 200 (7.87) 00 (15.7) Central (factory setting) 150 g/l (9. lb/ft³) 150 g/l (9. lb/ft³) 250 g/l (15.6 lb/ft³) 60 g/l (3.7 lb/ft³) 25 g/l (1.6 lb/ft³) 25 g/l (1.6 lb/ft³) 15 g/l (0.9 lb/ft³) 50 g/l (3.1 lb/ft³) SITRANS LPS200, dimensions in mm (inch) Siemens FI 01 June 2015 /125

126 Point level measurement - Rotation paddle switches SITRANS LPS200 Schematics AC or DC version, SPDT, fail-safe Switching and timing behaviour: If the vane is not covered, the rotating vane shaft will send pulses at 20 second intervals. In case of fault, the pulses are missed. After 30 seconds, the alarm relay will open. Alarm output Signal output L N PE + - OR 2 V or 8 V or 115 V or 230 V AC, 50/60 Hz, 5 VA 2 V DC, 2.5 W All voltages ± 15 % Voltage selector 2 V 115 V AC version DPDT FSH/FSL Max. mm 2 (AWG12) Universal voltage (DPDT relay) Max. mm 2 (AWG12) 230 V Signal output DPDT L N PE + - Power Supply Signal output DPDT Alarm output 2) L N PE + - Power Supply 2) With option Fail safe alarm (rotation control). Contact open when de-energised SITRANS LPS200 connections /126 Siemens FI 01 June 2015

127 Overview Point level measurement - Ultrasonic non-contacting switch Pointek ULS200 Application The measuring range for bulk solids is max. 3 m (9.8 ft) and 5 m (16. ft) for liquids and slurries. Unlike invasive contacting devices, there is no material buildup on the sensor. The level switch has a rugged design, combining the transducer and electronics in one durable device. It has no moving parts and is virtually maintenance-free. The transducer, available in ETFE or PVDF copolymer, is inert to most chemicals. This means the device can be used in the chemical, petrochemical, water, and wastewater industries. A sanitary version of the ULS200, with an industry standard flange option, is easy to remove from the application for cleaning. It thus satisfies the prerequisites for use in the food, beverage, and pharmaceutical industries. The Pointek ULS200 delivers superior performance while reducing maintenance, downtime, and equipment replacement costs. Key Applications: liquids, slurries, fluid materials, plugged chute detection, chemical industry The Pointek ULS200 is an ultrasonic non-contacting switch with two switch points for level detection of bulk solids, liquids and slurries in a wide variety of industries; ideal for sticky materials. Benefits 2 switch outputs for high-high, high, low and low-low level alarms or pump up/pump down control Integral temperature compensation AC or DC power supply Electronics provided with fail-safe function Threaded and sanitary fitting clamp process connections Polycarbonate enclosure, Type 6/NEMA 6/IP67 Easy, two-button programming Design Installation The Pointek ULS200 should be mounted in an area that is within the temperature range specified and that is suitable to the enclosure rating and materials of construction. The cover should be accessible to allow programming, wiring and display viewing. It is advisable to keep the Pointek ULS200 away from high voltage or current runs, contactors and SCR control drives. Locate the Pointek ULS200 so that it has a clear sound path perpendicular to the material surface. The sound path should not intersect the fill path, rough walls, seams, rungs etc. Mounting and Interconnection The Pointek ULS200 is available in three thread types: 2" NPT, R 2" (BSPT), EN or PF2 and can be fitted with the optional 75 mm (3 inch) flange adapter for mating to 3" ASME, DN 65, PN 10, and JIS 10K 3B sized flanges. Separate cables and conduit may be required to conform to standard instrumentation wiring or electrical codes. Siemens FI 01 June 2015 /127

128 Point level measurement - Ultrasonic non-contacting switch Pointek ULS200 Configuration Parabolic mounting Flat mounting and Beam angle Fill Pipe Rungs Seams 12 Beam angle Pointek ULS200 Mounting /128 Siemens FI 01 June 2015

129 Point level measurement - Ultrasonic non-contacting switch Pointek ULS200 Technical specifications Mode of operation Measuring principle Ultrasonic level switch Measuring range Measuring range in liquids m ( ft) Measuring range in bulk solids m ( ft) Output AC Version (relay) 2 SPDT Form C contacts, rated 5 A at 250 V AC or 30 V DC, resistive load; rated 1 A at 8 V DC resistive load DC Version (relay) 2 SPDT Form C contacts, rated 5 A at 30 V DC, resistive load; rated 1 A at 8 V DC resistive load DC Version (transistor) 2 switches, rated max. 100 ma, 8 V DC Accuracy AC/DC version Resolution 3 mm (0.1 inch) Repeatability 0.25 % of measuring range Rated operation conditions Installation conditions Location Indoors/outdoors Beam angle 12 Ambient conditions Ambient temperature C ( F) If mounted in metal threads C ( F) Medium conditions Process pressure 0.5 bar (7.25 psi) max. Design Material Polycarbonate with gasket Weight Approx. 1.5 kg (3.3 lb) Transducer material PVDF or ETFE copolymer Threaded mounting 2" NPT [(Taper), ANSI/ASME B1.20.1] R 2" [(BSPT), EN 10226] or G 2" [(BSPP), EN ISO 228-1] Optional flange adapter For 3" ASME, DN 65, PN 10 and JIS 10 K3B Sanitary mounting " sanitary fitting clamp Power supply AC version V AC, ± 15 %, 50/60 Hz, max. 12 VA, 5 W DC version V DC, 3 W Displays and controls Display LCD, three digits, 9 mm (0.35 inch) high, for display of distance between sensor face and material, multi-segment graphic for operating state Memory EEPROM, non-volatile Programming 2 keys Electronics/enclosure Connection: terminal block, max. 2.5 mm 2 (1 AWG) solid/ 1.5 mm 2 (16 AWG) stranded Degree of protection IP67/Type 6/NEMA 6 Cable inlet 2 x ½" NPT or 2 x PG 13.5 Certificates and approvals CE (EMC certificate available on request), CSA US/C, FM Options Flange adapter for mating 2" NPT or 2" BSP process connections to 3" ASME, DN 65 PN 10 and JIS 10K 3B flanges 18.8 (5.86) bolt hole circle diameter (7.9) diameter Pointek ULS200 Optional Flange Adapter, dimensions in mm (inch) Siemens FI 01 June 2015 /129

130 Point level measurement - Ultrasonic non-contacting switch Pointek ULS200 Pointek ULS200 Ultrasonic non-contacting switch with two switch points for level detection of bulk solids, liquids and 7ML slurries in a wide variety of industries; ideal for sticky materials Click on the for the online configuration in the PIA Life Cycle Portal. Power supply 2 V DC, relay output 1 2 V DC, transistor output V AC, relay output 3 Approvals CE, RCM, CSA Class I, II, Div. 2 1) J CE, RCM, CSA us/c, FM K Transducer/Process connection ETFE, 2" NPT [(Taper), ANSI/ASME B1.20.1] A EFTE, R 2" [(BSPT), EN 10226] B EFTE, G 2" [(BSPP), EN ISO 228-1] C PVDF copolymer, 2" NPT [(Taper), ANSI/ASME B1.20.1] E PVDF copolymer, R 2" [(BSPT), EN 10226] F PVDF copolymer, G [(BSPP), EN ISO 228-1] G PVDF copolymer, " sanitary mounting 2) J Enclosure/cable inlet Polycarbonate Cable inlet PG Cable inlet ½" NPT 2 1) Available with Enclosure/cable inlet option 2 only 2) Available with Approvals option K only We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 9/5 in the appendix. Order code Further designs Please add "-Z" to and specify Order code(s) Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Y15 Measuring-point number/identification (max. 27 characters) specify in plain text Operating Instructions Quick Start manual, multi-language A5E This device is shipped with the Siemens Milltronics manual DVD containing the ATEX Quick Start and Operating Instructions library. Accessories Tag, stainless steel, 12 x 5 mm (0.7 x 1.77 inch), 7ML1930-1AC one text line, suitable for enclosures Universal Box Bracket Mounting Kit 7ML1830-1BK 3" ASME, DN 65 PN 10, JIS 10K 3B ETFE Flange 7ML1830-1BT adapter for 2" NPT 3" ASME, DN 65 PN 10, JIS 10K 3B ETFE Flange 7ML1830-1BU adapter for 2" BSPT 2" BSPT Locknut, plastic 7ML1830-1DQ 2" NPT Locknut 7ML1830-1DT " sanitary mounting clamp 7ML1830-1BR Spare Parts Polycarbonate Lid 7ML1830-1LG We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 9/5 in the appendix. /130 Siemens FI 01 June 2015

131 Point level measurement - Ultrasonic non-contacting switch Pointek ULS200 Dimensional drawings Schematics Threaded Relay output (2.35) 7 (2.9) V AC 50/60 Hz L N Lid clip #8-32x3/8" machine screw 57 (2.25) or V DC Two Form C (SPDT) relays can switch external devices such as alarms, relays, contactors, PLCs, DCSs, etc. Lid Conduit connection ½" NPT or PG (7.1) Transistor output: DC version only V DC + - 2" NPT R 2" BSPT or PF2 Transducer 22 (0.87) 7 (2.9) Two non-polarized transistor outputs are suitable for connection to PLCs, DCSs, or customer supplied relays. Sanitary Pointek ULS200 connections 180 (7.1) 7 (2.9) Pointek ULS200, dimensions in mm (inch) Siemens FI 01 June 2015 /131

132 Continuous level measurement - Ultrasonic Ultrasonic Overview Mode of operation Introduction Common Terms Ultrasonic measurement is based on the speed of sound. Sound Attenuation can be used as a measurement tool because there is a measurable time lapse between sound generation and the "hearing" of the sound. This time lapse is then converted into usable information. Ultrasonic sensing equipment generates a sound above Hz and then interprets the time lapse of the returned echo. The transducer creates the sound and senses the echo Beam angle and then a transceiver interprets the sound and converts it into information. Siemens ultrasonic units include Sonic Intelligence, a signal processing technology. Using unique algorithms, Sonic Intelligence differentiates between true echoes from the material and false echoes from obstructions or electrical noise, providing intelligent Blanking distance processing of echo profiles. Typical System Ultrasonic level measurement requires two components: one to generate the sound and catch the echo (transducer) and one to Echo confidence interpret the data and derive a measurement (transceiver). Even though some ultrasonic instruments combine the components in one unit, the individual functionality remains distinct. The measurement output is communicated to the unit, PLCs or PCs for Ringing process control. Principle of Operation A piezoelectric crystal inside the transducer converts an electrical signal into sound energy, firing a burst into the air which trav- Transducer/Transceiver els to the target and then is reflected back to the transducer. The transducer then acts as a receiving device and converts the sonic energy back into an electrical signal contained in the transceiver. An electronic signal processor analyzes the return echo and calculates the distance between the transducer and the target. The time lapse between firing the sound burst and receiving the return echo is directly proportional to the distance between the transducer and the material in the vessel. This basic principle lies at the heart of the ultrasonic measurement technology and is illustrated in the equation: Distance = (Velocity of Sound x Time)/2. Denotes a decrease in signal magnitude in transmission from one point to another. Attenuation may be expressed as a scalar ratio of the input magnitude to the output magnitude or in decibels. The diameter of a conical boundary centered around the axis of transmission when the power (radiating perpendicular to the transducer face on the axis of transmission) is reduced by half (-3 db). Specified zone extending downward from the transducer face in which received echoes are ignored by the transceiver. Blanking distance ignores echoes from ringing. The recognition of the validity of the echo as material level. A measure of echo reliability. The inherent nature of the transducer to continue vibrating after the transmit pulse has ceased; the decay of the transmit pulse. A transducer provides the initial ultrasonic pulse and receives its echo. An ultrasonic transducer amplifies the sound wave created by the piezoelectric crystal and transmits that sound wave to the face of the transducer while at the same time dampening the sound wave from the other sides of the crystal. Transceivers analyze the echo from the transducer to determine the required measurement. /132 Siemens FI 01 June 2015

133 Continuous level measurement - Ultrasonic Ultrasonic Technical specifications Ultrasonic Transmitter/Controller Selection Guide Criteria SITRANS Probe LU SITRANS LUT00 HydroRanger 200 MultiRanger 100/200 SITRANS LU Range 6 m (20 ft) or 12 m (0 ft) Typical applications Output Communications Power specifications Chemical storage vessels, filter beds, liquid storage vessels HART model: ma/hart PROFIBUS PA model: PROFIBUS HART or PROFIBUS PA Options: SIMATIC PDM for remote configuration and diagnostics HART: ma, 2 V DC nominal, max. 550 Ω, 30 V DC max. PROFIBUS PA: 12, 13, 15, or 20 ma, dependent on programming m ( ft), transducer and application dependent Wet wells, reservoirs, flumes/weirs, chemical storage, liquid storage, hoppers, crusher bins, dry solids storage...20ma/hart 3 relays HART 7.0, USB, SIMATIC PDM AC version: V AC ± 15 %, 50/60 Hz, 36 VA Fuse: 5 x 20 mm, Slow Blow, 0.25 A, 250 V DC version: V DC, 10 W Fuse: 5 x 20 mm, Slow Blow, 1.6 A, 125 V 15 m (50 ft) transducer and application dependent Wet wells, flumes/weirs, bar screen control 6 relays standard, two ma outputs (isolated) Built-in Modbus RTU/ ASCII via RS-85 Options: SIMATIC PDM SmartLinx (PROFIBUS DP, DeviceNet) AC version: V AC ± 15 %, 50/60 Hz, 36 VA/17 W DC version: V DC, 20 W 15 m (50 ft) transducer and application dependent Wet wells, flumes/weirs, bar screen control, hoppers, chemical storage, liquid storage, crusher bins, dry solids storage 1 relay (option on MultiRanger 100) 3 relays standard 6 relays (option) Two ma outputs (isolated) Built-in Modbus RTU or ASCII via RS-85 Options: SIMATIC PDM SmartLinx (PROFIBUS DP, DeviceNet) AC version: V AC ± 15 %, 50/60 Hz, 36 VA/17 W DC version: V DC, 20 W 60 m (200 ft) transducer and application dependent Chemical storage, liquid storage, bulk solids storage (sugar, flour bins, grains, cereals), plastic pellets relays (LU01, LU02) Up to 0 relays (LU10) ma isolated Dolphin, RS 232/RS 85 (LU01, LU02) Dolphin via infrared (LU10) LU01, LU02: AC version: 100/115/200/ 230 V AC DC version: V DC, 25 W LU10: 100/115/200/230 V AC Approvals CE, CSA US/C, FM, RCM, ATEX, IECEx CE, CSA US/C, UL Listed, FM, RCM, Lloyd's Register, ABS CE, CSA US/C, UL Listed, FM, RCM CE, CSA US/C, UL Listed, FM, RCM CE, CSA US/C, FM, Lloyd s Register Siemens FI 01 June 2015 /133

134 Continuous level measurement - Ultrasonic Ultrasonic 7ML1830-2AN 7ML5830-2AJ 7ML1830-2AK SITRANS Probe LU HART* SITRANS LU SITRANS Probe LU PROFIBUS MultiRanger 100/200 HydroRanger 200 * Note: To order the IS version of this hand programmer, order 7ML5830-2AH. Handheld programmer selection guide /13 Siemens FI 01 June 2015

135 Continuous level measurement - Ultrasonic Ultrasonic Application Ultrasonic Level Application Questionnaire Customer information Contact: Prepared By: Company: Date: Address: Notes on the Application: City: Zip/Postal Code: Fax: Country: Phone: ( ) Tanks/Vessel information (Supply sketch where possible) Sketch attached Type: Storage Dimensions: Critical Information Process Height: m/ft Nozzle Length: cm/inch Pump station Width/Diameter: m/ft Nozzle Diameter: cm/inch Open channel Tank top: Open Tank bottom: Sloped Internal equipment No Flat Flat and/or obstructions: (Eg. Agitator, heating coils, Yes Conical Conical supports, other) Please list Parabolic Parabolic Measurement type: Point Level Continuous Level Volume Flow Area safety classification: (Specify code required) Material Material being measured: Slurry Liquid Solid Material temperature: Norm: C/ F Max: C/ F Atmosphere: Air Other Homogenous: Yes No Dust: None Light Heavy Installation Power available: (indicate all that apply) Communications: Inputs required: Outputs required: HART/ ma DeviceNet ma ma Pump Interlocks (#): Relays (#): PROFIBUS DP PROFIBUS PA Modbus RTU/ASCII Other None Products recommended: Siemens Milltronics Process Instruments Inc. Update 03/2015 Ultrasonic Application Questionnaire Siemens FI 01 June 2015 /135

136 Continuous level measurement - Ultrasonic transmitters SITRANS Probe LU Overview Configuration Parabolic mounting SITRANS Probe LU is a 2-wire loop powered ultrasonic transmitter for level, volume and flow monitoring of liquids in open channels, storage vessels, and simple process vessels. Benefits Continuous level measurement up to 12 m (0 ft) range Easy installation and simple start-up Programming using infrared Intrinsically Safe handheld programmer, SIMATIC PDM or HART Communicator Communication using HART or PROFIBUS PA ETFE or PVDF transducers for chemical compatibility Sonic Intelligence signal processing Auto False-Echo Suppression for fixed obstruction avoidance Level to volume or level to flow conversion Flat mounting and beam angle Pipe Rungs Fill Application The SITRANS Probe LU is ideal for level monitoring in the water and wastewater industry, chemical storage vessels, and small bulk hoppers. The range of SITRANS Probe LU is 6 or 12 m (20 or 0 ft). Using Sonic Intelligence, Auto False Echo Suppression for fixed obstruction avoidance, and accuracy of 0.15 % of range or 6 mm (0.25 inch), the Probe LU provides unmatched reliability. The Probe LU offers two communications options: HART or PROFIBUS PA (Profile version 3.0, Class B). The transducer on the Probe LU is available as ETFE or PVDF to suit the chemical conditions of your application. As well, for applications with varying material and process temperatures, the Probe LU incorporates an internal temperature sensor to compensate for temperature changes. Key Applications: chemical storage vessels, filter beds, liquid storage vessels Seams SITRANS Probe LU mounting 10 Beam angle /136 Siemens FI 01 June 2015

137 Continuous level measurement - Ultrasonic transmitters SITRANS Probe LU Technical specifications Mode of operation Measuring principle Ultrasonic level measurement Typical application Level measurement in storage vessels and simple process vessels Inputs Measuring range 6 m (20 ft) model m (10 inch ft) 12 m (0 ft) model m (10 inch... 0 ft) Frequency 5 khz Outputs ma/hart Range ma Accuracy ± 0.02 ma PROFIBUS PA Profile 3, Class B Performance Resolution 3 mm (0.12 inch) Accuracy ± the greater of 0.15 % of range or 6 mm (0.2 inch) Repeatability 3 mm (0.12 inch) Blanking distance 0.25 m (10 inch) Update time 5 s /20 ma/hart version 5 s at ma PROFIBUS version s at 15 ma current loop Temperature compensation Built-in to compensate over temperature range Beam angle 10 Rated operating conditions Ambient conditions Location Indoor/outdoor Ambient temperature C ( F) Relative humidity/ingress protection Suitable for outdoor Installation category I Pollution degree Medium conditions Temperature at flange or threads C ( F) Pressure (vessel) 0.5 bar g (7.25 psi g) Design Material (enclosure) PBT (Polybutylene Terephthalate) Degree of protection Type X/NEMA X, Type 6/NEMA 6/ IP67/IP68 enclosure Weight 2.1 kg (.6 lb) Cable inlet 2 x M20x1.5 cable gland or 2 x ½" NPT thread or 1 x M20 x 1.5 and 1 x ½" NPT Material (transducer) ETFE (Ethylene Tetrafluoroethylene) or PVDF (Polyvinylidene Fluoride) Process connection Threaded connection Flange connection Other connection Display and Controls Interface Configuration Memory Power supply 2" NPT [(Taper), ANSI/ASME B1.20.1] R 2" [(BSPT), EN 10226] or G 2" [(BSPP), EN ISO 228-1] 3 inch (80 mm) universal flange FMS 200 mounting bracket (see page 5/189) or customer supplied mount Local: LCD display with bar graph Remote: Available via HART or PROFIBUS PA Using Siemens SIMATIC PDM (PC) or HART handheld communicator or Siemens infrared handheld programmer Non-volatile EEPROM ma/hart Nominal 2 V DC with 550 Ω maximum; maximum 30 V DC ma PROFIBUS PA 12, 13, 15, or 20 ma depending on programming (General Purpose or Intrinsically Safe version) Per IEC Certificates and Approvals General CSA US/C, FM, CE, RCM Marine (only applies to HART communication option) Hazardous Intrinsically Safe (Europe) Lloyd s Register of Shipping ABS Type Approval ATEX II 1G Ex ia IIC T Ga Intrinsically Safe (USA/Canada) CSA/FM, Class I, Div. 1, Groups A, B, C, D; Class II, Div. 1, Groups E, F, G; Class III T Intrinsically Safe (International) SIR X Ex ia IIC T Ga Intrinsically Safe (Brazil) INMETRO Ex ia IIC T Ga Non-incendive (USA) FM Class I, Div. 2, Groups A, B, C, D T Handheld Programmer Intrinsically Safe Siemens handheld Infrared receiver programmer Approvals for handheld programmer ATEX II 1GD / IECEx SIR Ex ia IIC T Ga Ex iad 20 T135 C FM/CSA Class I, II, III, Div. 1, Groups A,B,C,D,E,F,G T6 Ambient temperature C ( F) Interface Proprietary infrared pulse signal Power 3 V lithium battery (non-replaceable) Siemens FI 01 June 2015 /137

138 Continuous level measurement - Ultrasonic transmitters SITRANS Probe LU SITRANS Probe LU 2-wire, loop powered ultrasonic transmitter for level, volume and flow monitoring of liquids in 7ML open channels, storage vessels, and simple process vessels. Click on the for the online configuration in the PIA Life Cycle Portal. Enclosure/Cable Inlet Plastic (PBT), 1 x M20x1.5 and 1 x ½" NPT 0 (no cable glands supplied) Plastic (PBT), 2 x M20x1.5 (includes 1 general 1 purpose cable gland: 7ML1930-1AM) Plastic (PBT), 2 x ½" NPT 2 (no cable glands supplied) Range/Transducer material 6 m (20 ft), ETFE A 6 m (20 ft), PVDF Copolymer B 12 m (0 ft), ETFE C 12 m (0 ft), PVDF Copolymer D Process connection 2" NPT [(Taper), ANSI/ASME B1.20.1] A R 2" [(BSPT), EN 10226] B G 2" [(BSPP), EN ISO 228-1] C Communication/Output ma, HART 1 PROFIBUS PA 2 Approvals General Purpose, FM, CSA US/C, CE, RCM, KCC 1 Non-incendive, FM Class I, Div. 2 Groups A,B,C,D T5 1) Intrinsically Safe, CSA/FM Class I, Div. 1, Groups A, 5 B, C, D; Class II, Div. 1, Groups E, F, G; Class III T 2) Intrinsically Safe ATEX 1G / IECEx / INMETRO 6 Ex ia IIC T Ga, RCM, KCC 2) Intrinsically Safe ATEX 1G / IECEx / INMETRO 7 Ex ia IIC T Ga, RCM, KCC 3) Intrinsically safe, CSA/FM Class I, Div. 1, Groups A, 8 3) B, C, D; Class II, Div. 1 Groups E, F, G; Class III T 1) Available with Enclosure/Cable Inlet option 2 only. 2) Available with communication option 2 only. 3) Available with communication option 1 only. We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 9/5 in the appendix. Order code Further designs Please add "-Z" to and specify Order code(s). Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Y15 Measuring-point number/identification (max. 27 characters) specify in plain text Operating Instructions for HART/mA device English A5E French 7ML1998-5HT11 German A5E Note: The Operating Instructions should be ordered as a separate item on the order. Additional Multi-language Quick Start manual A5E This device is shipped with the Siemens Milltronics manual DVD containing the ATEX Quick Start and Operating Instructions library. Operating Instructions for PROFIBUS PA device English A5E German A5E Note: The Operating Instructions should be ordered as a separate item on the order. Additional Multi-language Quick Start manual A5E This device is shipped with the Siemens Milltronics manual DVD containing the ATEX Quick Start and Operating Instructions library. Accessories Handheld programmer, Intrinsically Safe, EEx ia 7ML5830-2AH Handheld programmer, General Purpose approvals 7ML1830-2AN Handheld programmer, Infrared, Intrinsically Safe, 7ML5830-2AJ PROFIBUS PA HART modem/usb 7MF997-1DB (for use with a PC and SIMATIC PDM) 2" NPT locknut, plastic 7ML1830-1DT 2" BSPT locknut, plastic 7ML1830-1DQ 3" ASME, DN 65 PN 10, JIS 10K 3B ETFE Flange 7ML1830-1BT adapter for 2" NPT 3" ASME, DN 65 PN 10, JIS 10K 3B ETFE Flange 7ML1830-1BU adapter for 2" BSPT One General Purpose polymeric cable gland 7ML1930-1AM M20x1.5, rated for C ( F) One metallic cable gland M20x1.5, 7ML1930-1AP rated C ( F) for General Purpose or ATEX EEx e installations (available for HART only) One metallic cable gland M20x1.5, 7ML1930-1AQ rated C ( F) with integrated shield connection (available for PROFIBUS PA) Probe LU, rock guard/sunshield kit, 7ML1930-1GH 30 stainless steel SITRANS RD100, loop powered display - 7ML see Chapter 7 SITRANS RD200, universal input display with 7ML Modbus conversion - see Chapter 7 SITRANS RD300, dual line display with totalizer 7ML and linearization curve and Modbus conversion - see Chapter 7 SITRANS RD500 web, universal remote monitoring 7ML solution for instrumentation - see Chapter 7 For applicable back up point level switch see point level measurement section. Spare Parts Plastic lid 7ML1830-1KB /138 Siemens FI 01 June 2015

139 Continuous level measurement - Ultrasonic transmitters SITRANS Probe LU Options Flange adapter for mating 2" NPT or 2" BSP process connections to 3" ASME, DN 65 PN 10 and JIS 10K 3B flanges SITRANS Probe LU with FMS 200 mounting bracket 18.8 (5.86) Bolt hole circle diameter (7.9) Diameter SITRANS Probe LU optional flange adapter, dimensions in mm (inch) Dimensional drawings SITRANS Probe LU with optional mounting bracket (5.50) (5.12) Hinged lid (7.83) Electronics 51.1 (2.01) 5 (2.13) 21 (0.83) Mounting thread Transducer Note: Above model is shown without M20 cable glands or 1/2" NPT conduit connectors. SITRANS Probe LU, dimensions in mm (inch) Siemens FI 01 June 2015 /139

140 Continuous level measurement - Ultrasonic transmitters SITRANS Probe LU Schematics Lid screws Terminals for loop current or PROFIBUS PA cable Connect the wires to the terminals as shown: the polarity is identified on the terminal block. Cable Watertight gland Note: - HART model above is shown with M20 cable glands. 1/2" NPT threaded connection is also available. - DC terminal shall be supplied from an SELV source in accordance with IEC Annex H. - All field wiring must have insulation suitable for rated input voltages. - Separate cables and conduit may be required to conform to standard instrumentation wiring practices or electrical codes. SITRANS Probe LU connections /10 Siemens FI 01 June 2015

141 Continuous level measurement - Ultrasonic transmitters The Probe Overview Configuration Parabolic mounting The Probe is a short-range integrated ultrasonic level transmitter, ideal for liquids and slurries in open or closed vessels. Benefits Easy to install, program and maintain Accurate and reliable Sanitary models available Sonic Intelligence echo processing Integral temperature compensation Flat mounting and beam angle Fill Application The transducer is available in PVDF copolymer, making the device suitable for use in a wide variety of applications. The Probe is easy to install and maintain, and can be quickly removed for cleaning as required by the food, beverage and pharmaceutical industries. The reliability of the level data is based on the Sonic Intelligence echo processing algorithms. A filter discriminates between the true echo and false echoes from acoustic or electrical noises and agitator blades in motion. The ultrasonic pulse propagation time to the material and back is temperature-compensated and converted into distance for display, analog output and relay actuation. Key Applications: chemical storage vessels, filter beds, mud pits, liquid storage vessels, food applications Pipe Rungs Seams The Probe mounting 12 Beam angle Siemens FI 01 June 2015 /11

142 Continuous level measurement - Ultrasonic transmitters The Probe Technical specifications Mode of operation Measuring principle Input Measuring range Three-wire version Ultrasonic level measurement m ( ft) Two-wire version (standard) Ultrasonic level measurement m ( ft) Frequency 5 khz 5 khz Output ma ma ma Span Proportional/ inversely proportional Proportional/ inversely proportional Max. load 750 Ω at 2 V DC 600 Ω in the loop at 2 V DC Relay For level alarm or fault No Power supply Supply voltage V DC, max. 0.2 A V DC, 0.1 A surge 0.75 W (25 ma at 2 V DC) CE, RCM, CSA US/C 0.25 % of measuring range (in air) 3 mm (0.125 inch) Built in Sonic Intelligence Beam angle 12 Ambient temperature Standard C ( F) Metallic mounting C ( F) Max. static operating Normal atmospheric pressure pressure Degree of protection IP65 Design Weight Without flange adapter 1.5 kg (3.3 lb) With flange adapter 1.7 kg (3.7 lb) Material Electronics enclosure PVC Transducer PVDF copolymer Degree of protection IP65 Process connection 2" NPT [(Taper), ANSI/ASME B1.20.1] R 2" [(BSPT), EN 10226] or G 2" [(BSPP), EN ISO 228-1] Flange adapter 3" Universal, (fits DN 65, PN 10 and 3"ASME) " sanitary Cable inlet 2 inlets for PG 16 or ½" NPT cable glands Max. power consumption 5 W (200 ma at 2 V DC) Certificates and CE, RCM, CSA US/C, FM approvals Accuracy Error in measurement Resolution Temperature compensation Echo processing Rated operation conditions The Probe 7ML1201- Short-range integrated ultrasonic level transmitter, ideal for liquids and slurries in open or closed vessels Click on the for the online configuration in the PIA Life Cycle Portal. Measuring range 5 m (16.0 ft) 1 Transducer/Process connection PVDF copolymer, 2" NPT [(Taper), E ANSI/ASME B1.20.1] PVDF copolymer, R 2" [(BSPT), EN 10226] F PVDF copolymer, G 2" [(BSPP), EN ISO 228-1] G PVDF copolymer, " Sanitary mounting J Model/Approval 3 Wire, 2 V DC, CE, RCM, CSA, FM E 2 Wire, 2 V DC, CE, RCM, CSA F We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 9/5 in the appendix. Order code Further designs Please add "-Z" to and specify Order code(s). Acrylic coated, stainless steel tag [13 x 5 mm Y17 (0.5 x 1.75 inch)]: Measuring-point number/ identification (max. 20 characters) specify in plain text Additional Operating Instructions 3 Wire, 2 V model, Multi-language manual 7ML1998-5GD62 2 Wire model, Multi-language manual A5E Accessories Universal Box Bracket Mounting kit 7ML1830-1BK Sanitary " mounting clamp 7ML1830-1BR 3" ASME, DN 65 PN 10, JIS 10K 3B ETFE Flange 7ML1830-1BT adapter for 2" NPT 3" ASME, DN 65 PN 10, JIS 10K 3B ETFE Flange 7ML1830-1BU adapter for 2" BSPT 2" NPT locknut, plastic 7ML1830-1DT 2" BSPT locknut, plastic 7ML1830-1DQ Plastic M20 cable gland with metal locknut 7ML1930-1DB SITRANS RD100, loop powered display - 7ML see Chapter 7 SITRANS RD200, universal input display with 7ML Modbus conversion - see Chapter 7 SITRANS RD300, dual line display with totalizer 7ML and linearization curve and Modbus conversion - see Chapter 7 SITRANS RD500 web, universal remote monitoring 7ML solution for instrumentation - see Chapter 7 For applicable back up point level switch see point level measurement section. We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 9/5 in the appendix. /12 Siemens FI 01 June 2015

143 Continuous level measurement - Ultrasonic transmitters The Probe Options Dimensional drawings Flange adapter for mating 2" NPT or 2" BSP process connections to 3" ANSI, DN 65 PN10, and JIS 10K 3B flanges Standard model Hinged lid 18.8 (5.86) bolt hole circle diameter (7.9) diameter The Probe Optional Flange Adapter, dimensions in mm (inch) The Probe with FMS 200 mounting bracket 117 (.6) Cable entry knock out 87 (3.) Ø Mounting thread 279 (11) 7 (0.3) 7 (2.9) 8 (3.3) max. Electronics Mounting thread Transducer 61 (2.) 53 (2.1) max. Sanitary model The Probe with Optional Mounting Bracket Schematics 3 wire model (standard and sanitary models) ma output: ma, nonisolated, 750 Ω max. Power supply 117 (.6) Hinged lid Cable entry knock out 87 (3.) Ø 279 (11) 7 (0.3) 8 (3.3) max. Electronics Process connection Connect to protective earth Relays: dry contact, closed unpowered or alarm state 7 (2.9) Transducer 2 wire model (standard and sanitary models) Probe Loop instrumentation R max + 61 (2.) The Probe, dimensions in mm (inch) 53 (2.1) max. R max = 12 V 20 ma V V DC supply V supply + Display Program mode Segment display '20' key '' key Operation status LOE/fault Units The Probe connections Siemens FI 01 June 2015 /13

144 Continuous level measurement - Ultrasonic controllers SITRANS LUT00 series Overview The Siemens SITRANS LUT00 series controllers are compact, single point, long-range ultrasonic controllers for continuous level or volume measurement of liquids, slurries, and solids, and high accuracy monitoring of open channel flow. Application The SITRANS LUT00 comes in three different models, depending on the application, level of performance and functionality required: SITRANS LUT20 Level Controller: Level or volume measurement of liquids, slurries, and solids, as well as basic pump control functions, and basic data logging capability SITRANS LUT30 Level, Pump and Flow Controller: Includes all features of the LUT20 plus a full suite of advanced pump control and alarm functionality, open channel flow monitoring, and basic flow data logging capability SITRANS LUT0 High Accuracy OCM: Our most featured, highest accuracy model. Includes all features of the LUT30, plus the industry s best accuracy (± 1 mm within 3 m), full suite of advanced control functionality, and enhanced flow logging capability Key applications: wet wells, reservoirs, flumes/weirs, chemical storage, liquid storage, hoppers, crusher bins, dry solids storage Benefits Small 1/2 DIN enclosure [1 h x 1 d x 16 w mm (5.7 x 5.7 x 5.75 inch)] with standard universal mounting bracket for wall, pipe, and DIN rail, plus an optional panel mount Easy to use HMI display with local four-button programming, menu-driven parameters, and Wizard support for key applications English, German, French, Spanish, Chinese, Italian, Portuguese, and Russian texts on the HMI. Level, Volume, OCM Flow monitoring Three relays combined with a suite of pump, alarm, and relay control features HART Communications EDDs for SIMATIC PDM, AMS Device Manager, and Field Communicator 375/75, plus DTMs for FDTs (Field Device Tools) Web browser for local programming from an intuitive webbased interface Two discrete inputs for backup level override and pump interlock functions Echo profile and trend views from the local display Patented digital receiver for improved performance in electrically noisy applications (close proximity to VSDs) Real time clock with daylight savings time, supporting an integrated datalogger and energy saving algorithms for minimizing pump operation during high cost energy periods Removable terminal blocks for ease of wiring MCERTS Certified for Open Channel Flow /1 Siemens FI 01 June 2015

145 Continuous level measurement - Ultrasonic controllers SITRANS LUT00 series Technical specifications Mode of Operation Measuring range Input Discrete Output Transducer frequency Ultrasonic transducer Relays ma output Max. load Resolution Accuracy Error in measurement Resolution Temperature compensation Ultrasonic level, volume, pump, and open channel flow m (1 196 ft), transducer dependent V DC switching level Logical 0 10 V DC Logical 1 = V DC Max. 3 ma khz Compatible transducers: All EchoMax and ST-H series transducers 1 SPDT Form C, NO or NC relay, rated 1A at 250 V AC, non-inductive and 3A at 30 V DC 2 SPST Form A, NO relays, rated 5A at 250 V AC, non-inductive and 3 A at 30 V DC 20 ma, isolated 600 Ω max. in ACTIVE mode, 750 Ω max. in PASSIVE mode 0.1 % of range Standard operation: ± 1 mm (0.0 inch) plus 0.17 % of measured distance High accuracy OCM: ± 1 mm (0.0 inch), within 3 m (9.8 ft) range Standard operation: 0.1 % of range or 2 mm (0.08 inch), whichever is greater High accuracy OCM: 0.6 mm (0.02 inch), within 3 m (9.8 ft) range C ( F) Integral temperature sensor in transducer External TS-3 temperature sensor (optional) Programmable fixed temperature values Rated operating conditions Installation conditions Location Indoor/outdoor Installation category II Pollution degree Ambient conditions Ambient temperature (enclosure) C ( F) Design Weight Enclosure with display lid 1.3 kg (2.87 lb) Enclosure with blank lid: 1.2 kg (2.65 lb) Material (enclosure) Polycarbonate Degree of protection Enclosure with display or blank lid: IP65/Type X/NEMA X Enclosure with blank lid and knockout removed: IP20 Remote display lid IP65/Type 3/NEMA 3 Cable Transducer and ma output signal Transducer, ma output: 2 copper conductors, twisted, with foil shield/drain wire, 300 V mm² (22 18 AWG) Relay/power to be copper conductors per local requirements to meet 250 V 5 A contact rating Max. separation between 365 m (1 200 ft) transducer and transceiver Displays and controls 60 x 0 mm (2.36 x 1.57 inch) removable LCD, 20 x 160 pixels resolution, operational up to 5 m from enclosure base Programming Primary Local push buttons Secondary PC running SIMATIC PDM PC running Emerson AMS Device Manager PC running a web browser PC running a Field Device Tool (FDT) Field Communicator 375/75 (FC375/FC75) Memory 512 kb flash EPROM 1.5 MByte flash for data logging Power supply AC version V AC ± 15 %, 50/60 Hz, 36 VA Fuse: 5 x 20 mm, Slow Blow, 0.25 A, 250 V DC version V DC, 10 W Fuse: 5 x 20 mm, Slow Blow, 1.6 A, 125 V Certificates and approvals General CSA US/C, CE, FM, UL listed, RCM, MCERTS certified for Open Channel Flow Hazardous Non-incendive (Canada) Shipping Communication CSA Class I, Div. 2, Groups A, B, C, D; Class II, Div. 2, Groups F, G; Class III Lloyd's Register, ABS HART 7.0, USB Siemens FI 01 June 2015 /15

146 Continuous level measurement - Ultrasonic controllers SITRANS LUT00 series SITRANS LUT20 SITRANS LUT30 SITRANS LUT0 Category Feature Level Controller Level, pump and flow controller High accuracy OCM controller Operations Level, space, and distance measurement Open channel flow measurement Volume conversion Specifications Compatible with EchoMax and ST-H transducers Standard accuracy: ± 1 mm % of measured distance High accuracy: ± 1 mm within 3 meters Mounting options: wall or panel, pipe, DIN-rail Data logging and communications Flow monitoring Pump control HART communications ma output (active and passive) Integrated datalogger for measurement value and alarms Integrated datalogger for fixed rate flow logging Integrated datalogger for variable rate flow logging trig- gered by changes in flow condition Daily data logging for maximum, minimum and average flow, daily totalized volume, and minimum and maximum temperature High accuracy open channel flow measurement 9 digit daily and running flow totalizers High and low flowrate alarms External totalizer and sampler control MCERTS Class 1 Certification MCERTS Class 2 Certification Energy saving algorithms for pump control Wall cling reduction Pump run-on functionality Pump start and power resumption delays Alternate duty pump routines Fixed duty and service ratio pump routines Pumped volume totalizer Submergence detection Discrete input pump interlocks Time to spill calculation /16 Siemens FI 01 June 2015

147 Continuous level measurement - Ultrasonic controllers SITRANS LUT00 series 0 SITRANS LUT20 and LUT30 Compact ultrasonic level controllers for continuous short to long-range level or volume measurement of 7ML liquids, slurries, and solids. Both units include basic relay functions for pumps, alarms, and other controls, plus onboard data logging. LUT30 offers additional advanced pump control and alarm functionality, open channel flow monitoring, and basic flow data logging capability. Functionality varies by model. Click on the for the online configuration in the PIA Life Cycle Portal. Model SITRANS LUT20 - Level controller A SITRANS LUT30 - Level, Pump & Flow controller B Enclosure display options With display A With remote panel mount display B [Includes panel mount cable extension, 2.5 m (8.2 ft)] No display (blank lid provided) C Note: Enclosure includes back-plate for wall and pipe mounting, and an integrated clip for DIN-rail mounting. DIN-rail mounting for standard TS35 x 7.5 and TS35 x 15 mm DIN-rail to IEC 60715, EN Input voltage V AC ± 15 % V DC 2 Cable inlet 3 cable inlets, cable glands not supplied 1 3 cable inlets, 3 M20 plastic cable glands supplied 2 Number of measurement points Single point system (includes one transducer input, 1 one ma output, and one external temperature sensor input) Communications and I/O HART, 2 discrete inputs, 3 relays D Approvals General purpose CE, FM, CSA US/C, UL, RCM A Hazardous locations CSA Class I, II, III, Div. 2 (Groups A, B, C, D, F, G) C We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 9/5 in the appendix. Order code Further designs Please add "-Z" to and specify Order code(s). Manufacturer's test certificate M to DIN 55350, C11 Part 18 and to ISO 9000 Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Y15 Measuring-point number/identification (max. 27 characters) specify in plain text Namur NE3 failsafe setting - device preset to N07 failsafe < 3.6 ma Operating Instructions English A5E French 7ML1998-5MV11 Spanish 7ML1998-5MV21 German A5E Italian 7ML1998-5MV51 Multi-language compact operating instructions 7ML1998-5XU81 Note: The operating instructions should be ordered as a separate line item on the order. Communications Manual English French Spanish German Italian Note: The communications manual should be ordered as a separate line item on the order. Accessories Tag, stainless steel, 12 x 5 mm (0.7 x 1.77 inch), one text line, suitable for enclosure TS-3 Temperature Sensor - see TS-3 on page /189 Panel mount cable extension, 2.5 m (8.2 ft) Qty 3 cable glands and retaining nuts USB cable, 2 m (6.56 ft) - Standard USB-A to USB-mini B Hart modem/usb (for use with a PC and SIMATIC PDM) Sunshield, 30 stainless steel SITRANS RD100, loop powered display - see Chapter 7 SITRANS RD200, universal input display with Modbus conversion - see Chapter 7 SITRANS RD300, dual line display with totalizer and linearization curve and Modbus conversion - see Chapter 7 SITRANS RD500 web, universal remote monitoring solution for instrumentation - see Chapter 7 Spare parts Panel mount retrofit kit (convert standard unit with display to panel mount version) Terminal block replacement kit (5 piece kit with one of each removable terminal) Wall/Pipe mount plate Enclosure (include blank label) SITRANS LUT00 Lid (with Display) SITRANS LUT00 Lid (blank) Fuse - AC (0.25 A, 250 V, Slow Blow) Fuse - DC (1.6 A, 125 V, Slow Blow) Battery BR2032 Panel mount gasket and fastener kit DIN-rail clip A5E ML1998-5NE11 7ML1998-5NE21 7ML1998-5NE31 7ML1998-5NE51 7ML1930-1AC 7ML ML1930-1GF 7ML1930-1GB 7ML1930-1GD 7MF997-1DB 7ML1930-1GE 7ML ML ML ML ML1830-1PA 7ML1830-1PB 7ML1830-1PC 7ML1830-1PD 7ML1830-1PE 7ML1830-1PF 7ML1830-1PG 7ML1830-1PH 7ML1830-1PJ 7ML1830-1PK 7ML1830-1PL We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 9/5 in the appendix. Siemens FI 01 June 2015 /17

148 Continuous level measurement - Ultrasonic controllers SITRANS LUT00 series 0 SITRANS LUT0 7ML5050- The SITRANS LUT0 is the most accurate and featured model in the LUT00 series. It includes high accuracy open channel monitoring, relay functions for external samplers, totalizers, alarms, and enhanced data logging, as well as all pump and control functions available with other models in the LUT00 series. Click on the for the online configuration in the PIA Life Cycle Portal. Model SITRANS LUT0 - High accuracy Open Channel Monitor 1) C Enclosure display options With display A With remote panel mount display B [Includes panel mount cable extension, 2.5 m (8.2 ft)] No display (blank lid provided) C Note: Enclosure includes back-plate for wall and pipe mounting, and an integrated clip for DIN-rail mounting. DIN-rail mounting for standard TS35 x 7.5 and TS35 x 15 mm DIN-rail to IEC 60715, EN Input voltage V AC ± 15 % V DC 2 Cable inlet 3 cable inlets, cable glands not supplied 1 3 cable inlets, 3 M20 plastic cable glands supplied 2 Number of measurement points Single point system (includes one transducer input, 1 one ma output, and one external temperature sensor input) Communications and I/O HART, 2 discrete inputs, 3 relays D Approvals General purpose CE, FM, CSA US/C, UL, RCM A Hazardous locations CSA Class I, II, III, Div. 2, C (Groups A, B, C, D, F, G) 1) Compatible with all EchoMax Transducers. High accuracy OCM performance with the use of an XRS-5 transducer and TS-3 temperature sensor (each sold separately). We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 9/5 in the appendix. Order code Further designs Please add "-Z" to and specify Order code(s). Manufacturer's test certificate M to DIN 55350, C11 Part 18 and to ISO 9000 Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Y15 Measuring-point number/identification (max. 27 characters) specify in plain text Namur NE3 failsafe setting - device preset to N07 failsafe < 3.6 ma Operating Instructions English A5E French 7ML1998-5MV11 Spanish 7ML1998-5MV21 German A5E Italian 7ML1998-5MV51 Note: The operating instructions should be ordered as a separate line item on the order. Communications Manual English French Spanish German Italian Note: The communications manual should be ordered as a separate line item on the order. Accessories Tag, stainless steel, 12 x 5 mm (0.7 x 1.77 inch), one text line, suitable for enclosure TS-3 Temperature Sensor - see TS-3 on page /189 Panel mount cable extension 2.5 m (8.2 ft) Qty 3 cable glands and retaining nuts USB cable 2 m (6.56 ft) - Standard USB-A to USB-mini B HART modem/usb (for use with PC and SIMATIC PDM) Sunshield, 30 stainless steel SITRANS RD100, loop powered display - see Chapter 7 SITRANS RD200, universal input display with Modbus conversion - see Chapter 7 SITRANS RD300, dual line display with totalizer and linearization curve and Modbus conversion - see Chapter 7 SITRANS RD500 web, universal remote monitoring solution for instrumentation - see Chapter 7 Spare parts Panel mount retrofit kit (convert standard unit with display to panel mount version) Terminal block replacement kit (5 piece kit with one of each removable terminal) Wall/Pipe mount plate Enclosure (include blank label) SITRANS LUT00 Lid (with Display) SITRANS LUT00 Lid (blank) Fuse - AC (0.25 A, 250 V, Slow Blow) Fuse - DC (1.6 A, 125 V, Slow Blow) Battery BR2032 Panel mount gasket and fastener kit DIN-rail clip A5E ML1998-5NE11 7ML1998-5NE21 7ML1998-5NE31 7ML1998-5NE51 7ML1930-1AC 7ML ML1930-1GF 7ML1930-1GB 7ML1930-1GD 7MF997-1DB 7ML1930-1GE 7ML ML ML ML ML1830-1PA 7ML1830-1PB 7ML1830-1PC 7ML1830-1PD 7ML1830-1PE 7ML1830-1PF 7ML1830-1PG 7ML1830-1PH 7ML1830-1PJ 7ML1830-1PK 7ML1830-1PL We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 9/5 in the appendix /18 Siemens FI 01 June 2015

149 Continuous level measurement - Ultrasonic controllers SITRANS LUT00 series Dimensional drawings Back mount bracket Enclosure SITRANS LUT (7.8) 190 (7.5) 22 (0.87) 1 (5.7) 3 (1.3) 98 Cable entry (3 places) 259 (10.2) 155 (6.10) 16 (5.75) SITRANS LUT00, dimensions in mm (inch) Siemens FI 01 June 2015 /19

150 Continuous level measurement - Ultrasonic controllers SITRANS LUT00 series ± 1.00 (0.53 ± 0.0) 1.80 ± 1.00 (0.07 ± 0.0) ± 1.00 (.33 ± 0.0) 5.50 (0.22) dia. ( places) (.92) ± 1.00 (3.81 ± 0.0) 6.25 (0.25) rad. ( places) Cut-out Note: Cut-out template (printed to scale) shipped with remote panel mount model (.92) SITRANS LUT00, dimensions in mm (inch) /150 Siemens FI 01 June 2015

151 Continuous level measurement - Ultrasonic controllers SITRANS LUT00 series Schematics INPUT POWER 1.6 A,125 V SLOW BLOW V TS-3 TRANSDUCER DISCRETE INPUTS INPUT POWER BK L WHT SHLD BLK WHT DC SYNC 0.25 A, 250 V SLOW BLOW L1 L2/N RELAYS ma OUT/ HART BATTERY BR2032 DISPL AY RLY 1 RLY 2 RLY 3 ACT PAS SERVICE SITRANS LUT00 connections Siemens FI 01 June 2015 /151

152 Continuous level measurement - Ultrasonic controllers MultiRanger 100/200 Overview MultiRanger is a versatile short to medium-range ultrasonic single and multi-vessel level monitor/controller for virtually any application in a wide range of industries. Benefits Digital input for back-up level override from point level device Communication using built-in Modbus RTU via RS 85 Compatible with SmartLinx system and SIMATIC PDM configuration software Single or dual point level monitoring Auto False-Echo Suppression for fixed obstruction avoidance Differential amplifier transceiver for common mode noise reduction and improved signal-to-noise ratio MultiRanger 100: level measurements, simple pump control, and level alarm functions MultiRanger 200: level, volume and flow measurements in open channels, differential control, extended pump control, and alarm functions Wall and panel mounting options Application MultiRanger can be used on different materials, including fuel oil, municipal waste, acids, woodchips, or on materials with high angles of repose. MultiRanger offers true dual point monitoring, digital communications with built-in Modbus RTU via RS 85, as well as compatibility with SIMATIC PDM, allowing PC configuration and setup. MultiRanger features Sonic Intelligence advanced echo-processing software for increased reading reliability. MultiRanger 100 offers cost-effective level alarming, as well as on/off and alternating pump control. MultiRanger 200 will monitor open channel flow and features more advanced relay alarming and pump control functions as well as volume conversion. It is compatible with chemical-resistant EchoMax transducers that can be used in hostile environments at temperatures as high as 15 C (293 F). Key Applications: wet wells, flumes/weirs, bar screen control, hoppers, chemical storage, liquid storage, crusher bins, dry solids storage Design The MultiRanger is available in wall or panel mounting options. /152 Siemens FI 01 June 2015

153 Continuous level measurement - Ultrasonic controllers MultiRanger 100/200 Technical specifications Mode of Operation Measuring principle Ultrasonic level measurement Measuring range m ( ft) Measuring points 1 or 2 Input Analog (MultiRanger 200 only) ma or ma, from alternate device, scalable Discrete V DC switching level Logical V DC Logical 1 = V DC Max. 3 ma Output EchoMax transducer khz Ultrasonic transducer Compatible transducers: ST-H and EchoMax series XPS-10, XPS 15/15F, and XRS-5 Relays Rating 5 A at 250 V AC, non-inductive Version with 1 relay (MultiRanger SPST Form A only) Version with 3 relays 2 SPST Form A/1 SPDT Form C Version with 6 relays SPST Form A/2 SPDT Form C ma output ma or ma Max. load 750 Ω, isolated Resolution 0.1 % of range Accuracy Error in measurement 0.25 % of range or 6 mm (0.2 inch), whichever is greater Resolution 0.1 % of measuring range 1) or 2 mm (0.08 inch), whichever is greater Temperature compensation C ( F) Integral temperature sensor External TS-3 temperature sensor (optional) Programmable fixed temperature values Rated operating conditions Installation conditions Location Indoor/outdoor Installation category II Pollution degree Ambient conditions Ambient temperature (housing) C ( F) Design Weight Wall mount 1.37 kg (3.02 lb) Panel mount 1.50 kg (3.31 lb) Material (enclosure) Polycarbonate Degree of protection (enclosure) Wall mount IP65/Type X/NEMA X Panel mount IP5/Type 3/NEMA 3 Electrical connection Transducer and ma output signal 2-core copper conductor, twisted, shielded, mm² ( AWG), Belden 8760 or equivalent is acceptable Max. separation between transducer 365 m (1 200 ft) and transceiver Displays and controls 100 x 0 mm ( x 1.5 inch) multiblock LCD with backlighting Programming Programming using hand-held programmer, SIMATIC PDM or via PC with Dolphin Plus software Power supply AC version V AC ± 15 %, 50/60 Hz, 36 VA (17 W) DC version V DC (20 W) Certificates and approvals CE, RCM 2) Lloyd s Register of Shipping ABS Type Approval FM, CSA US/C, UL listed CSA Class I, Div. 2, Groups A, B, C and D, Class II, Div.2, Groups F and G, Class III (wall mount only), ATEX II 3D Communication RS 232 with Modbus RTU or ASCII via RJ-11 connector RS 85 with Modbus RTU or ASCII via terminal strips Optional: SmartLinx cards for -PROFIBUS DP - DeviceNet 1) Program range is defined as the empty distance to the face of the transducer plus any range extension 2) EMC performance available on request Siemens FI 01 June 2015 /153

154 Continuous level measurement - Ultrasonic controllers MultiRanger 100/200 MultiRanger 100/200 Versatile short to medium-range ultrasonic single and multi-vessel level monitor/controller for virtually 7ML any application in a wide range of industries Click on the for the online configuration in the PIA Life Cycle Portal. Versions MultiRanger 100, level measurement only 1 MultiRanger 200, level, volume, flow and differential 2 measurements Mounting, enclosure design Wall mount, standard enclosure A Wall mount, entries, M20 cable glands included B Panel mount (CE, CSA US/C, FM, UL) C Power supply V AC A V DC B Number of measurement points Single point version 0 Dual point version 1 Communication (SmartLinx) Without module 0 SmartLinx PROFIBUS DP module 2 SmartLinx DeviceNet module 3 See SmartLinx product on page /362 for more information. Output relays 3 relays (2 Form A, 1 Form C), 250 V AC 1 6 relays ( Form A, 2 Form C), 250 V AC 2 1 relay (1 Form A), 250 V AC 3 (available on MultiRanger 100 model only) Approvals General Purpose CE, FM, CSA US/C, UL listed, RCM A CSA Class I, Div. 2, Groups A, B, C and D; Class II, B Div. 2, Groups F and G; Class III 1) ATEX II 3D 2) C 1) For wall mount applications only 2) For standard enclosure wall mount, option A only We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 9/5 in the appendix. Order code Further designs Please add "-Z" to and specify Order code(s). Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Y15 Measuring-point number/identification (max. 27 characters) specify in plain text Operating Instructions English 7ML1998-5FB06 French 7ML1998-5FB13 Spanish 7ML1998-5FB23 German 7ML1998-5FB36 Quick Start guide, multi-language 7ML1998-5QD83 Note: The Operating Instructions should be ordered as a separate item on the order. This device is shipped with the Siemens Milltronics manual DVD containing the ATEX Quick Start and Operating Instructions library. Other Operating Instructions SmartLinx PROFIBUS DP, English 7ML1998-1AQ03 SmartLinx PROFIBUS DP, German 7ML1998-1AQ33 SmartLinx PROFIBUS DP, French 7ML1998-1AQ13 SmartLinx DeviceNet, English 7ML1998-1BH02 Note: The appropriate SmartLinx Operating Instructions should be ordered as a separate line on the order. Accessories Handheld programmer 7ML1830-2AK Tag, stainless steel, 12 x 5 mm (0.7 x 1.77 inch), 7ML1930-1AC one text line, suitable for enclosure M20 cable gland kit ( M20 cable glands, 7ML1930-1FV M20 nuts, washers) Sunshield kit, 30 stainless steel 7ML1930-1GA SITRANS RD100, loop powered display - 7ML see Chapter 7 SITRANS RD200, universal input display with 7ML Modbus conversion - see Chapter 7 SITRANS RD300, dual line display with totalizer 7ML and linearization curve and Modbus conversion - see Chapter 7 SITRANS RD500 web, universal remote monitoring 7ML solution for instrumentation - see Chapter 7 Spare parts Power Supply Board ( V AC) 7ML1830-1MD Power Supply Board ( V DC) 7ML1830-1ME Display Board 7ML1830-1MF We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 9/5 in the appendix. /15 Siemens FI 01 June 2015

155 Continuous level measurement - Ultrasonic controllers MultiRanger 100/200 Dimensional drawings Schematics Wall mount version Mounting 1.9 holes (0.58) (6.325) Ø (5.125) (0.17) (x) (3.58) (0.26) (0.6) Suitable location for conduit entrances Siemens Milltronics recommends using a hole punch for drilling the holes. Panel mount version 198 (7.80) Cover screws (x6) Housing Mounting screw (provided by customer) Mounting holes (accessed under lid) Ø.3 (0.17) (x) 36 (1.0) 97 (3.82) 227 (8.93) 20 (9.5) TB See note 1 Relay 1 Relay 2 Relay 3 Relay Relay V DC version TB1 SYNC - ma INPUT + SHIELD ma + OUTPUTS TS-3 - SHIELD 1 DISCRETE INPUTS L2/N L1 2 TB1 TB3 278 (10.9) MultiRanger, dimensions in mm (inch) Relay 6 Relays shown in released state COM RS 85 A B Note: 1. Use 2-core copper wire, twisted, with shield, for expansion up to 365 m (1 200 ft). Route cable in grounded metal conduit, separate from other cables. 2. Verify that all system components are installed in accordance with instructions. 3. Connect all cable shields to the MultiRanger shield connections. Avoid differential ground potentials by not connecting cable shields to ground (earth) anywhere else.. Keep exposed conductors on shielded cables as short as possible to reduce noise on the line caused by stray transmissions and noise pickup. MultiRanger connections Siemens FI 01 June 2015 /155

156 Continuous level measurement - Ultrasonic controllers HydroRanger 200 Overview HydroRanger 200 is an ultrasonic level controller for up to six pumps and provides control, differential control, and open channel flow monitoring. Benefits Monitors wet wells, weirs and flumes Digital communications with built-in Modbus RTU via RS 85 Compatible with SmartLinx system and SIMATIC PDM configuration software Single or dual point level monitoring 6 relay (standard), 1 or 3 relay (optional) Auto False-Echo Suppression for fixed obstruction avoidance Anti-grease ring/tide mark buildup Differential amplifier transceiver for common mode noise rejection and improved signal-to-noise ratio Wall and panel mounting options Application For water authorities, municipal water, and wastewater plants, HydroRanger 200 is an economical, low-maintenance solution delivering control efficiency and productivity needed to meet today s exacting standards. It offers single point monitoring with all models, and optional dual-point monitoring with 6 relay model. As well, it has digital communications with built-in Modbus RTU via RS 85. The standard 6 relay HydroRanger 200 will monitor open channel flow and features more advanced relay alarming and pump control functions as well as volume conversion. It is compatible with SIMATIC PDM, allowing for PC configuration and setup. Sonic Intelligence advanced echo-processing software provides increased reading reliability. The optional 1 or 3 relay models provide accurate level measurement functions only; these two models do not provide open channel flow, differential level measurement or volume conversion functions. HydroRanger 200 uses proven continuous ultrasonic echo ranging technology to monitor water and wastewater of any consistency up to 15 m (50 ft) in depth. Achievable resolution is 0.1 % with accuracy to 0.25 % of range. Unlike contacting devices, HydroRanger 200 is immune to problems caused by suspended solids, harsh corrosives, grease or silt in the effluent, reducing downtime. Key Applications: wet wells, flumes/weirs, bar screen control /156 Siemens FI 01 June 2015

157 Continuous level measurement - Ultrasonic controllers HydroRanger 200 Technical specifications Mode of Operation Measuring principle Ultrasonic level measurement Measuring range m ( ft), transducer dependent Measuring points 1 or 2 Input Analog ma or ma, from alternate device, scalable (6 relay model) Discrete V DC switching level Logical V DC Logical 1 = V DC Max. 3 ma Output EchoMax transducer khz Ultrasonic transducer Compatible transducers: ST-H and EchoMax series XPS-10, XPS 15/15F, and XRS-5 Relays 1) Rating 5 A at 250 V AC, non-inductive Model with 1 relay 2) 1 SPST Form A Model with 3 relays 2) 2 SPST Form A/1 SPDT Form C Model with 6 relays SPST Form A/2 SPDT Form C ma output ma or ma Max. load 750 Ω, isolated Resolution 0.1 % of range Accuracy Error in measurement 0.25 % of range or 6 mm (0.2 inch), whichever is greater Resolution 0.1 % of measuring range or 2 mm (0.08 inch), whichever is greater 3) Temperature compensation C ( F) Integral temperature sensor in transducer External TS-3 temperature sensor (optional) Programmable fixed temperature values Rated operating conditions Installation conditions Location Indoor / outdoor Installation category II Pollution degree Ambient conditions Ambient temperature (enclosure) C ( F) Design Weight Wall mount 1.37 kg (3.02 lb) Panel mount 1.50 kg (3.31 lb) Material (enclosure) Polycarbonate Degree of protection (enclosure) Wall mount IP65/Type X/NEMA X Panel mount IP5/Type 3/NEMA 3 Cable Transducer and ma output signal 2-core copper conductor, twisted, shielded, 300 Vrms, 0.82 mm² (18 AWG), Belden or equivalent is acceptable Max. separation between transducer 365 m (1 200 ft) and transceiver Displays and controls 100 x 0 mm ( x 1.5 inch) multiblock LCD with backlighting Programming Programming using handheld programmer or via PC with SIMATIC PDM software Power supply ) AC version V AC ± 15 %, 50/60 Hz, 36 VA (17 W) DC version V DC (20 W) Certificates and approvals CE, RCM 5) Lloyd's Register of Shipping ABS Type Approval FM, CSA US/C, UL listed CSA US/C Class I, Div. 2, Groups A, B, C and D, Class II, Div. 2, Groups F and G, Class III (wall mount only) MCERTS Class 3 approved for Open Channel Flow Communication RS 232 with Modbus RTU or ASCII via RJ-11 connector RS 85 with Modbus RTU or ASCII via terminal blocks Optional: SmartLinx cards for -PROFIBUS DP - DeviceNet 1) All relays certified for use with equipment that fails in a state at or under the rated maximums of the relays 2) This model is level control only; no open channel flow, differential level or volume conversion functions 3) Program range is defined as the empty distance to the face of the transducer plus any range extension ) Maximum power consumption is listed 5) EMC performance available upon request Siemens FI 01 June 2015 /157

158 Continuous level measurement - Ultrasonic controllers HydroRanger 200 Siemens HydroRanger 200 7ML503- Ultrasonic level controller for up to six pumps that provides control, differential control and open channel flow monitoring. The HydroRanger 200 is also available as a level measurement controller only. Select option from number of measurement points options below. Click on the for the online configuration in the PIA Life Cycle Portal. Mounting Wall mount, standard enclosure 1 Wall mount, entries, M20 cable glands included 2 Panel mount 1) 3 Power supply V AC A V DC B Number of measurement points Single point model, 6 relays A Dual point model, 6 relays B Single point model, level only, 1 relay 2) C Single point model, level only, 3 relays 2) D Communication (SmartLinx) Without module 0 SmartLinx PROFIBUS DP module 2 SmartLinx DeviceNet module 3 See SmartLinx product on page /362 for more information. Approvals General Purpose CE, FM, CSA US/C, UL listed, RCM 1 CSA Class I, Div. 2, Groups A, B, C, and D; 2 Class II, Div. 2, Groups F and G; Class III (for wall mount applications only) Further designs Please add "-Z" to and specify Order code(s). Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Measuring-point number/identification (max. 27 characters) specify in plain text Operating Instructions English French German Note: The Operating Instructions should be ordered as a separate item on the order. This device is shipped with the Siemens Milltronics manual DVD containing the ATEX Quick Start and Operating Instructions library. Other Operating Instructions SmartLinx PROFIBUS DP, English SmartLinx PROFIBUS DP, German SmartLinx PROFIBUS DP, French SmartLinx DeviceNet, English Note: The appropriate SmartLinx Operating Instructions should be ordered as a separate line on the order. Accessories Handheld programmer Tag, stainless steel, 12 x 5 mm (0.7 x 1.77 inch), one text line, suitable for enclosure Sunshield kit, 30 stainless steel SITRANS RD100, loop powered display - see Chapter 7 Order code Y15 7ML1998-5FC03 7ML1998-5FC11 7ML1998-5FC33 7ML1998-1AQ03 7ML1998-1AQ33 7ML1998-1AQ13 7ML1998-1BH02 7ML1830-2AK 7ML1930-1AC 7ML1930-1GA 7ML ) Available with approval option 1 only 2) This model is level control only; no open channel flow, differential level, or volume conversion functions. SITRANS RD200, universal input display with Modbus conversion - see Chapter 7 SITRANS RD300, dual line display with totalizer and linearization curve and Modbus conversion - see Chapter 7 7ML ML SITRANS RD500 web, universal remote monitoring solution for instrumentation - see Chapter 7 7ML Spare parts Power Supply Board ( V AC) 7ML1830-1MD Power Supply Board ( V DC) 7ML1830-1ME Display Board 7ML1830-1MF /158 Siemens FI 01 June 2015

159 Continuous level measurement - Ultrasonic controllers HydroRanger 200 Dimensional drawings Schematics Wall mount version Mounting 1.9 holes (0.58) (6.325) Ø (5.125) (0.17) (x) (3.58) (0.26) (0.6) Suitable location for conduit entrances Siemens Milltronics recommends using a hole punch for drilling the holes. Panel mount version 198 (7.80) Cover screws (x6) Housing Mounting screw (provided by customer) Mounting holes (accessed under lid) Ø.3 (0.17) (x) 36 (1.0) 97 (3.82) 227 (8.93) 20 (9.5) TB See note 1 Relay 1 Relay 2 Relay 3 Relay Relay V DC version TB1 SYNC - ma INPUT + SHIELD ma + OUTPUTS TS-3 - SHIELD 1 DISCRETE INPUTS L2/N L1 2 TB1 TB3 278 (10.9) HydroRanger 200, dimensions in mm (inch) Relay 6 Relays shown in released state COM RS 85 A B Notes 1. Use 2-core copper wire, twisted, with shield, for expansion up to 365 m (1 200 ft.). Route cable in grounded metal conduit, separate from other cables. 2. Verify that all system components are installed in accordance with instructions. 3. Connect all cable shields to the HydroRanger 200 shield connections. Avoid differential ground potentials by not connecting cable shields to ground (earth) anywhere else.. Keep exposed conductors on shielded cables as short as possible to reduce noise on the line caused by stray transmissions and noise pickup. HydroRanger 200 connections Siemens FI 01 June 2015 /159

160 Continuous level measurement - Ultrasonic controllers SITRANS LU01 and LU02 Overview Overview The SITRANS LU01 is an ultrasonic long-range level controller for liquids and solids in a single vessel up to 60 m (200 ft). Handheld programmer shown is an accessory and must be ordered separately. The SITRANS LU02 is a dual point ultrasonic long-range level controller for liquids and solids in one or two vessels up to 60 m (200 ft). Handheld programmer shown is an accessory and must be ordered separately. Benefits Single point, long-range level monitoring Easy to install; easy to program using removable infrared keypad (optional) Compatible with all EchoMax transducers Backlit LCD display with reading in standard engineering units Automatic level-to-volume conversion for standard or custom tank shapes Dolphin Plus compatible High/low alarms Application Application The system consists of a SITRANS LU01 monitor linked to a noncontacting ultrasonic transducer that can be mounted up to 365 m (1 200 ft) away. The SITRANS LU01 will measure distance, level or volume, and it features Sonic Intelligence echo processing software for superior reliability. Readings are displayed in user-selectable linear engineering units on the backlit LCD. Modules for popular industrial buses can be factory installed or added later to meet changing needs. No external gateway is required, reducing hardware and cabling costs. Key Applications: chemical storage, liquid storage, bulk solids storage (gravel, flour bins, grains, cereals), plastic pellets Benefits Dual point, long-range level monitoring Easy to install; easy to program using removable infrared keypad (optional) Compatible with all EchoMax transducers Backlit LCD display with reading in standard engineering units Automatic level-to-volume conversion for standard or custom tank shapes Dolphin Plus compatible High/low alarms SITRANS LU02 will measure liquids, solids or a combination of both in one or two vessels of different sizes, shapes and configurations up to 60 m (200 ft). The system uses ultrasonic technology to measure level, space, distance, volume or average/differential. It features Sonic Intelligence echo processing software for superior reliability. Transducers can be mounted up to 365 m (1 200 ft) from the monitor. Readings are displayed in user-selectable linear engineering units on the backlit LCD. Key Applications: chemical storage, liquid storage, bulk solids storage (gravel, flour bins, grains, cereals), plastic pellets, tripper car /160 Siemens FI 01 June 2015

161 Continuous level measurement - Ultrasonic controllers SITRANS LU01 and LU02 Technical specifications Mode of operation Measuring principle Measuring range Measuring points Output signal Ultrasonic transducer Relays ma output Max. load Resolution Outputs Accuracy Error in measurement Resolution Temperature compensation Ultrasonic level measurement m ( ft) SITRANS LU01: Max. one point; SITRANS LU02: Max. two points EchoMax series, ST-H transducers SPDT Form C relays, rated at 5 A at 250 V AC, resistive load 0/ ma, optically isolated 750 Ω, isolated, 30 V 0.1 % of range SITRANS LU01: Max. one ma output SITRANS LU02: Max. two ma outputs 0.25 % of range or 6 mm (0.2 inch), whichever is greater 0.1 % of measuring range or 2 mm (0.08 inch), whichever is greater ºC ( ºF) Integral temperature sensor External TS-3 temperature sensor (optional) Programmable fixed temperature Rated operating conditions Ambient conditions Ambient temperature for enclosure ºC ( ºF) Design Weight 2.7 kg (6 lb) Material (enclosure) Polycarbonate Degree of protection (wall mount) IP65 Electrical connection Ultrasonic transducer cable extension RG62-A/U coaxial cable with low capacitance ma output signal 2-core copper conductor, twisted, shielded, mm² ( AWG), Belden or equivalent is acceptable Electrical connection and relay connection Synchronization Copper conductor according to local requirements, rated 250 V 5 A Up to 16 LU01/LU02 units can be synchronized together Power supply AC model 100/115/200/230 V AC ± 15 %, 50/60 Hz, 31 VA DC model V DC, 25 W Displays and controls 51 x 127 mm (2 x 5 inch) graphics LCD with backlighting Memory EEPROM (non-volatile), no backup battery required Programming Using removable programmer (ordered separately) or Dolphin Plus (option) Certificates and approvals CE, CSA US/C, FM, ATEX II 3D Lloyd's register of Shipping (Categories ENV1, ENV2, ENV3 and ENV5) Options External temperature sensor TS-3 Communications Dolphin Plus: Siemens Windowscompatible interface and ComVerter link (infrared) SITRANS LU01/LU02 7ML500- Single or dual point ultrasonic long-range level monitoring system for liquids and solids, and ranges up to 60 m (200 ft). Click on the for the online configuration in the PIA Life Cycle Portal. Number of measuring points LU01 version, 1 point 1 LU02 version, 2 points 2 Input voltage 100/115/200/230 V AC, voltage selector switch A V DC B Feature software Standard A Application software Standard 1 Data communications No module (SmartLinx ready) 0 Enclosure Wall mount 1 Wall mount, drilled, 6 x M20 3 Note: Cable glands are not included and should be ordered as a separate line on the order. Approvals CE, CSA US/C, FM 1) A CE B ATEX II 3D 2) C 1) Available with enclosure option 1 only 2) Available with enclosure option 3 only Siemens FI 01 June 2015 /161

162 P P X X P P X X Siemens AG 2015 Continuous level measurement - Ultrasonic controllers SITRANS LU01 and LU02 Further designs Please add "-Z" to and specify Order code(s). Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Measuring-point number/identification (max. 27 characters) specify in plain text Operating Instructions SITRANS LU01 English French German SITRANS LU02 English French German Note: The Operating Instructions should be ordered as a separate line item. This device is shipped with the Siemens Milltronics manual DVD containing the ATEX Quick Start and Operating Instructions library. Order code Y15 7ML1998-5BE02 7ML1998-5BE12 7ML1998-5BE32 7ML1998-5BD02 7ML1998-5BD12 7ML1998-5BD32 Accessories Handheld programmer Tag, stainless steel, 12 x 5 mm (0.7 x 1.77 inch), one text line, suitable for enclosures M20 cable gland kit (6 M20 cable glands, 6 M20 nuts, 3 stop plugs) M20 cable gland kit ( M20 cable glands, M20 nuts, washers) TS-3 Temperature Sensor - see TS-3 on page /189 Sunshield kit, 30 stainless steel Spare parts Card, LU01 mother main, AC, comm ready Card, LU02 mother main, AC, comm ready Card, LU02 daughter, comm ready Card, LU01 daughter, comm ready Card, display See SmartLinx product page /362 for more information. 7ML1830-2AN 7ML1930-1AC 7ML1830-1GM 7ML1930-1FV 7ML1830-2AN 7ML1930-1GA 7ML1830-1KX 7ML1830-1MA 7ML1830-1LP 7ML1830-1LN 7ML1830-1LQ Dimensional drawings 285 (11.2) 106 (.2) 267 (10.5) 92 (3.6) 285 (11.2) 106 (.2) 267 (10.5) 92 (3.6) % % 209 (8.2) 172 (6.8) ma (8.2) 172 (6.8) ma C % C % SITRANS LU 01 SITRANS LU 02 Suitable location for conduit entrances. Use water-tight conduit hubs to maintain enclosure rating. Mounting hole.3 (0.17) diameter access under lid ( places) Suitable location for conduit entrances. Use water-tight conduit hubs to maintain enclosure rating. Mounting hole.3 (0.17) diameter access under lid ( places) Dimensional drawings for SITRANS LU01 (left) and SITRANS LU02 (right), dimensions in mm (inch) /162 Siemens FI 01 June 2015

163 Continuous level measurement - Ultrasonic controllers SITRANS LU01 and LU02 Schematics AC model Note ma outputs Note 1 BLK WHT/SHLD 1 BLK WHT/SHLD Note 2 RS 85 2 BLK WHT/SHLD BLK WHT/SHLD 1 2 Temp. Temp. sensor sensor Relays Note 3 SHLD SHLD SHLD TX RX Bi-polar current loop TX RX RS 232 B A RS 85 COM COM SHLD SHLD SHLD SYNC L2/N L1 Position SW1 for 100/115/ 200/230 V AC Operation (50/60 Hz 31 VA) DC model ma outputs Note 1 BLK WHT/SHLD 1 Note 2 BLK WHT/SHLD 2 BLK WHT/SHLD BLK WHT/SHLD 1 2 Temp. Temp. sensor sensor Relays Note 3 SHLD SHLD SHLD TX RX Bi-polar current loop TX RX RS 232 B A Note COM COM SHLD SHLD SHLD SYNC + 2 V Notes: 1. Optically isolated, 750 Ω max. load 2. Use RG62-A/U coaxial (or equivalent) for extensions up to 365 m (1 200 ft). Run in grounded metal conduit, separate from other wiring. 3. Each relay has 1 set of Form 'C' (SPDT) contacts, relay rated at 5 A 250 V AC, non-inductive, when equal or lower rated limiting fuses are installed.. Required if mounted adjacent to other SITRANS LU01 units or other specified Siemens Milltronics devices. Interconnect all 'SYNC' terminals with a single 18 AWG (0.5 mm 2 ) wire. SITRANS LU01 connections AC model Note ma outputs Note 1 BLK WHT/SHLD 1 Note 2 BLK WHT/SHLD 2 BLK WHT/SHLD BLK WHT/SHLD 1 2 Temp. Temp. sensor sensor Relays Note 3 SHLD SHLD SHLD TX RX Bi-polar current loop TX RX RS-232 B A RS-85 COM COM SHLD SHLD SHLD SYNC L2/N L1 Position SW1 for 100/115/ 200/230 V AC Operation (50/60 Hz 31 VA) DC model Note Notes: ma outputs Note 1 1. Optically isolated, 750 Ω max. load 2. Use RG62-A/U coaxial (or equivalent) for extensions up to 365 m (1 200 ft). Run in grounded metal conduit, separate from other wiring. 3. Each relay has 1 set of Form 'C' (SPDT) contacts, relay rated at 5 A 250 V AC, non-inductive, when equal or lower rated limiting fuses are installed.. Required if mounted adjacent to other SITRANS LU01 units or other specified Siemens Milltronics devices. Interconnect all 'SYNC' terminals with a single 18 AWG (0.5 mm 2 ) wire. SITRANS LU02 connections BLK WHT/SHLD 1 Note 2 BLK WHT/SHLD 2 BLK WHT/SHLD BLK WHT/SHLD 1 2 Temp. Temp. sensor sensor Relays Note 3 SHLD SHLD SHLD TX RX Bi-polar current loop TX RX RS-232 B A RS-85 COM COM SHLD SHLD SHLD SYNC + 2 V Siemens FI 01 June 2015 /163

164 Continuous level measurement - Ultrasonic controllers SITRANS LU10 Overview Benefits Ten point, long-range level monitoring Automatic level-to-volume conversion for standard or custom tank shapes Dolphin Plus compatible Backlit LCD display with reading in standard engineering units Easy to install, easy to program using removable infrared keypad (optional) SITRANS LU10 is an ultrasonic long-range level monitor for liquids and solids, offering 10-point monitoring in a single unit. Handheld programmer shown is an accessory and must be ordered separately. Application It can be used in a wide range of applications to scan liquids, solids or a combination of both contained in vessels of differing size, shape, and configuration up to 60 m (200 ft). SITRANS LU10 uses ultrasonic technology to measure level, space, distance, volume, or average/differential. Transducers can be mounted up to 365 m (1 200 ft) from the monitor. The SITRANS LU10 features Sonic Intelligence echo processing software for superior reliability. Readings are displayed in userselectable linear engineering units on the LCD. Key Applications: chemical storage, liquid storage, bulk solids storage (sugar, flour bins, grains, cereals), plastic pellets, tank farms /16 Siemens FI 01 June 2015

165 Continuous level measurement - Ultrasonic controllers SITRANS LU10 Technical specifications Mode of operation Measuring principle Measuring range Measuring points Max. 10 Output Ultrasonic transducer Relays ma output Max. load Resolution Accuracy Error in measurement Resolution Temperature compensation Ultrasonic level measurement Max m ( ft) EchoMax series, ST-H transducers SPDT Form C relays, rated 5 A at 250 V AC, resistive load SITRANS LU AO module (option): 0/ ma, optically isolated 750 Ω, isolated 0.1 % of range 0.25 % of range or 6 mm (0.2 inch), whichever is greater 0.1 % of measuring range or 2 mm (0.08 inch), whichever is greater C ( F) Integral temperature sensor External TS-3 temperature sensor (expandable to 10 inputs with optional TIB-9 card) Programmable fixed temperature Rated operating conditions Ambient conditions Ambient temperature for enclosure C ( F) Design Weight 2.7 kg (6 lb) Material (enclosure) Polycarbonate Degree of protection (wall mount) IP65/Type X/NEMA X Electrical connection Ultrasonic transducer RG62-A/U coaxial cable with low capacitance Signal transmission 2-core copper conductor, twisted, shielded, mm² ( AWG), Belden 8760 or equivalent is acceptable Electrical connection and relay connection Synchronization Copper conductor according to local requirements, rated 250 V 5 A Up to 16 LU10 units can be synchronized together Power supply 100/115/200/230 V AC ± 15 %, 50/60 Hz, 31 VA Displays and controls 51 x 127 mm (2 x 5 inch) graphics LCD with backlighting Memory EEPROM (non-volatile), no backup battery required Programming Using removable programmer (ordered separately) or Dolphin Plus (option) Certificates and approvals CE, RCM, FM, CSA US/C, ATEX II 3D Lloyd's register of Shipping (Categories ENV1, ENV2, ENV3 and ENV5) Options Expansion card TIB-9, increases the number of TS-3 inputs from External temperature sensor TS-3 Communications Dolphin Plus: Siemens Windowscompatible interface and ComVerter link (infrared) I/O devices Max. 3 I/O devices per SITRANS LU10 SITRANS LU AO analog output module (max. 1) Siemens FI 01 June 2015 /165

166 Continuous level measurement - Ultrasonic controllers SITRANS LU10 SITRANS LU10 7ML5007- Ten point ultrasonic long-range level monitoring system for liquids and solids applications, and ranges up to 60 m (200 ft). Click on the for the online configuration in the PIA Life Cycle Portal. Input voltage 100/115, 200/230 V AC, selectable 1 Feature software Standard A Application software Standard A Data communications No module (SmartLinx ready) 0 TIB-9 temperature card None 0 With TIB-9 card 1 Enclosure Wall mount 1 Wall mount, drilled, 12 x M20 x1.5 for cable glands 2 Note: Cable glands are not included and should be ordered as a separate line on the order. Approvals CE, CSA US/C, FM 1) A ATEX II 3D 1) B CE, RCM 2) D 1) Available with enclosure option 1 only 2) Available with enclosure option 2 only Further designs Please add "-Z" to and specify Order code(s). Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Measuring-point number/identification (max. 27 characters) specify in plain text Operating Instructions English French German Accessories Handheld programmer Tag, stainless steel, 12 x 5 mm (0.7 x 1.77 inch), one text line, suitable for enclosures Temperature Card TIB 9-card M20 cable gland kit (6 M20 cable glands, 6 M20 nuts, 3 stop plugs) M20 cable gland kit ( M20 cable glands, M20 nuts, washers) TS-3 Temperature Sensor - see TS-3 on page /189 Sunshield kit, 30 stainless steel Spare parts Card, mother main, AC, comm ready Card, daughter, comm ready Card, display See SmartLinx product on page /362 for more information. Order code Y15 7ML1998-5AN02 7ML1998-5AN12 7ML1998-5AN32 7ML1830-2AN 7ML1930-1AC 7ML1830-1CN 7ML1830-1GM 7ML1930-1FV 7ML1930-1GA 7ML1830-1ML 7ML1830-1LY 7ML1830-1LQ /166 Siemens FI 01 June 2015

167 P P X X Siemens AG 2015 Continuous level measurement - Ultrasonic controllers SITRANS LU10 Dimensional drawings 285 (11.2) 106 (.2) 267 (10.5) 92 (3.6) % 209 (8.2) 172 (6.8) ma C % SITRANS LU 10 Suitable location for conduit entrances. Use water-tight conduit hubs to maintain enclosure rating. SITRANS LU10, dimensions in mm (inch) Mounting hole.3 (0.17) diameter access under lid ( places) Schematics black white/shield black white/shield black white/shield black white/shield black white/shield black white/shield black white/shield black white/shield transducers Note 1 To transducers (10 max.) RG62-A/U coax, 365 m / transducer max. black white/shield Temp. sensor Note SYNC TX Peripheral communication Note 3 RX P12 V L2/N L1 Position SW1 for 100/115/ 200/230 V AC Operation (50/60 Hz, 15 VA) Notes: 1. Transducer cables must be run in a grounded metal conduit separate from other wiring (except TS-3 temperature sensor wiring, if applicable). 2. Optional TIB-9 card for multiple temperature sensors. Do not jump the terminals if TS-3s are not used. 3. The SITRANS LU10 is compatible with the following Siemens Milltronics peripherals: - SITRANS LU AO - analog output module SITRANS LU10 connections Siemens FI 01 June 2015 /167

168 Continuous level measurement - Ultrasonic controllers SITRANS LU AO Overview The SITRANS LU AO Analog Output Module provides remote analog output for the measurement points of the SITRANS LU10 level monitor. Benefits Analog outputs can be up to m (5 000 ft) from the SITRANS LU 10 Analog outputs can be per transducer and/or average of 2 or more Application The operation of the SITRANS LU AO is programmed via the SITRANS LU10. The only on-board settings are for bank selection and output testing. The SITRANS LU AO can provide up to 10 analog outputs (each sharing a common negative bus which is electrically isolated from ground). Technical specifications Mode of operation Input Communications Transmission rate Voltage Polarization Max. load Output Analog outputs Data from SITRANS LU bits/s ± 20 ma bipolar current loop Non-polarized 1 receiving unit 10 analog outputs, programmable from SITRANS LU10 0 or ma, isolated ± 20 ma bipolar current loop Input and transmission Max. load 750 Ω Resolution 0.1 % Rated operating conditions Ambient conditions Ambient temperature for enclosure C ( F) Location Indoor/outdoor Installation category II Pollution degree Design Weight 2 kg (. lb) Material (enclosure) Polycarbonate Degree of protection Type X/NEMA X/IP65 Cable connection 2 copper conductors, twisted, with foil shield/drain wire, 300 V mm² ( AWG) Electrical connection and relay Copper conductor according to local connection requirements, rated 250 V 5 A Power supply 100/115/200/230 V AC ± 15 %, 50/60 Hz, 15 VA Displays and controls 1 LED for display of voltage/ communications state Certificates and approvals CE, FM, CSA US/C, RCM SITRANS LU AO Provides remote analog output for the measurement points of the SITRANS LU10 level monitor. Approvals: CSA US/C, FM, CE, RCM Operating Instructions English German Note: Operating Instructions should be ordered as a separate line item on the order. This device is shipped with the Siemens Milltronics manual DVD containing the Quick Start and Operating Instructions library. Accessories Sun Shield, 30 stainless steel 7ML5810-1A 7ML1998-5CE01 7ML1998-5CE31 7ML1930-1GA /168 Siemens FI 01 June 2015

169 Continuous level measurement - Ultrasonic controllers SITRANS LU AO Dimensional drawings 16 (0.6) 209 (8.2) 172 (6.8) Lid screws (6 places) 91 (3.6) SITRANS LU AO 267 (10.5) 285 (11.2) Mounting holes (accessed under lid).3 mm (0.17 inch) diameter places Suitable location for conduit entrances Lid Enclosure Mounting screw (by customer) SITRANS LU AO, dimensions in mm (inch) Schematics 230 V OFF 200 V Switch is shown in OFF position. Select appropriate voltage. 115 V See note 1 See note V SW3 Bi-polar Receiver spare See note 3 ma output ma output ma output ma output ma output 1 _ 2_ _ _ 7 + _ 8 + _ 9 + _ 10 + _ L2 /N L1 Isolated 0/ ma out, 750 Ω load max. (typical of 10) 100/115/200/230 V AC 50/60 Hz select voltage via switch Notes: 1. SITRANS LU AO receiver input is non-polarized. 2. Refer to associated application device instruction manual for wiring detail. Check that the communication parameter P70 (SITRANS LU10) is ON. 3. SITRANS LU AO interconnecting cable shield should be grounded at SITRANS LU10 only. Insulate shields at junctions to prevent inadvertent grounding. Maximum individual loop length is m ( ft). SITRANS LU AO connections Siemens FI 01 June 2015 /169

170 Continuous level measurement - Ultrasonic transducers Ultrasonic transducers Overview Ultrasonic Transducers Ultrasonic measuring systems are the cost-effective choice for monitoring and control in short- to long-range applications for liquids, slurries, and solids in a wide range of industries. Transducers are impervious to dust, moisture, corrosion, vibration, flooding, and extreme temperature. They are easy to install and virtually maintenance-free. Choose from a wide selection of models designed for short or long range applications on liquids or solids. Technical specifications EchoMax Transducers Max. range 1) 8 m (26 ft) Min. range 0.3 m (1 ft) Max. temperature 65 C (19 F) Min. temperature -20 C (- F) Typical Applications Wet wells and open channels Liquids Liquids and Solids Standard XRS-5 ST-H XPS-10 XPS-15 XPS m (33 ft) 0.3 m (1 ft) 73 C (16 F) -0 C (-0 F) Chemical storage and liquid tanks 10 m (33 ft) 0.3 m (1 ft) 95 C (203 F) -0 C (-0 F) Dusty solids and slurries 15 m (50 ft) 0.3 m (1 ft) 95 C (203 F) -0 C (-0 F) Deep wet wells and solids Frequency khz khz khz khz 30 khz Beam angle (-3dB) m (100 ft) 0.6 m (2 ft) 95 C (203 F) -0 C (-0 F) Powders, pellets and solids Thread size R 1" [(BSPT), EN 10226] 1" NPT 1" and 2" NPT R 2" [(BSPT), EN 10226], 2" [(BSPP), EN ISO 228-1] R 1" [(BSPT), EN 10226] 1" NPT R 1" [(BSPT), EN 10226] 1" NPT R 1.5" [(BSPT), EN 10226] Universal thread 1.5" NPT Enclosure PVDF Copolymer CSM Option: Flange with PTFE facing ETFE Option: PVDF PVDF Option: Foam facing PVDF Option: Foam facing PVDF Option: Foam facing Flange with PTFE facing Flange with PTFE facing Flange with PTFE facing Compatible with: SITRANS LUT00 SITRANS LU HydroRanger 200 MultiRanger 100/200 1) Application conditions such as extreme dust or angle of repose may reduce the usable maximum range. Consult your local Siemens representative for further information. /170 Siemens FI 01 June 2015

171 Continuous level measurement - Ultrasonic transducers ST-H Overview ST-H transducers use ultrasonic technology to measure level in chemical storage and liquid tanks. Benefits Can be mounted on a narrow standpipe Immune to corrosive and harsh environments Integral temperature sensor Application The narrow design of the ST-H allows the transducer to be mounted on a narrow standpipe. When mounted correctly, it is completely protected from the process and can even be used in harsh, corrosive environments. During operation, the ultrasonic transducer emits acoustic pulses in a narrow beam perpendicular to the transducer face. The level transceiver measures the propagation time between pulse emission and reception of the echo to calculate the distance from the transducer to the material. Variations in sound velocity due to changes in temperature within the permissible range are automatically compensated by the integral temperature sensor. Key Applications: chemical storage, liquid tanks Technical specifications Mode of operation Measuring principle Ultrasonic transducer Input Measuring range m ( ft) Output Frequency khz Beam angle 12 Accuracy Temperature compensation Compensated by integral temperature sensor Rated operating conditions Pressure Normal atmospheric pressure Ambient conditions Ambient temperature Design Weight 1) Material (enclosure) Process connection Degree of protection Cable connection Cable (max. length) Options Flange adapter C ( F) (ATEX approved model) C ( F) (CSA/FM approved model) 1. kg (3 lb) Base and lid made of ETFE or PVDF (epoxy fitted joint) 2) 2" NPT [(Taper), ANSI/ASME B1.20.1], R 2" [(BSPT), EN 10226] or G 2" [(BSPP), EN ISO 228-1] IP68 2-core shielded/twisted, mm² (20 AWG), PVC sheath 365 m (1 200 ft) with RG 62 A/U coaxial cable 3" Universal (fits DN 65, PN 10 and 3" ASME) Certificates and approvals CE, CSA Class I, II, III, Div. 1, Groups A, B, C, D, E, F, G T3 (ETFE only), FM Class I, II, Div. 1, Groups C, D, E, F, G TA, ATEX II 2G / INMETRO Ex mb IIC T5 Gb, RCM, KCC 1) Approximate shipping weight of transducer with standard cable length 2) When measuring chemicals, check compatibility of ETFE or PVDF and epoxy, or mount joint external to process. Siemens FI 01 June 2015 /171

172 Continuous level measurement - Ultrasonic transducers ST-H EchoMax ST-H ultrasonic transducer 7ML1100- Level measurement in chemical storage and liquid 7 7 A 7 0 tanks. The narrow design of the ST-H allows the transducer to be mounted on a 2 inch standpipe. Measuring range: min. 0.3 m (1 ft), max. 10 m (33 ft). Click on the for the online configuration in the PIA Life Cycle Portal. Process connection ETFE, 2" NPT [(Taper), ANSI/ASME B1.20.1] 0 ETFE, R 2" [(BSPT), EN 10226] 1 ETFE, G 2" [(BSPP), EN ISO 228-1] 2 PVDF copolymer, 2" NPT [(Taper), ANSI/ASME 3 B1.20.1] PVDF copolymer, R 2" [(BSPT), EN 10226] PVDF copolymer, G 2" [(BSPP), EN ISO 228-1] 5 Cable length 5 m (16.0 ft) A 10 m (32.81 ft) B 30 m (98.3 ft) C 50 m (16.0 ft) D 100 m ( ft) E Further designs Please add "-Z" to and specify Order code(s). Acrylic coated, stainless steel tag [13 x 5 mm (0.5 x 1.75 inch)]: Measuring-point number/ identification (max. 16 characters) specify in plain text Accessories Universal box bracket, mounting kit 3" ASME, DN 65 PN 10, JIS 10K 3B ETFE flange adapter for 2" NPT 3" ASME, DN 65 PN 10, JIS 10K 3B ETFE flange adapter for 2" BSPT Easy Aimer 2, aluminum, NPT with ¾" x 1" PVC coupling Easy Aimer 2, aluminum with M20 adapter and 1" and 1½" BSPT aluminum couplings Easy Aimer 30, NPT with 1" stainless steel coupling Easy Aimer 30, with M20 adapter and 1" and 1½" BSPT 30 stainless steel couplings Order code Y17 7ML1830-1BK 7ML1830-1BT 7ML1830-1BU 7ML1830-1AQ 7ML1830-1AX 7ML1830-1AU 7ML1830-1GN Approvals CE, FM Class I, II, Div. 1, Groups C,D,E,F,G TA 2 ATEX 2G / INMETRO Ex mb IIC T5 Gb, RCM, KCC 3 CSA Class I, II, III, Div. 1, Groups A,B,C,D,E,F,G T3 CE, ATEX 2G / INMETRO Ex mb IIC T5 Gb, RCM, KCC Operating Instructions Quick Start Manual, multi-language A5E Applications Guidelines, multi-language Note: The Applications Guidelines should be ordered as a separate line item on the order. 7ML1998-5HV61 This device is shipped with the Siemens Milltronics manual DVD containing the ATEX Quick Start and Operating Instructions library. 1) Available with Process connection options only 2) Available with Process connection options only 3) Not suitable for Ketone, Hexane, Ester or Ethyl Acetate atmospheres /172 Siemens FI 01 June 2015

173 Continuous level measurement - Ultrasonic transducers ST-H Dimensional drawings 1" NPT Conduit thread Mounting thread (process connection) 22 (0.87) 20.9 (0.82) 7 (2.9) 119 (.7) Flange Adapter Coupling Siemens Milltronics flange adapter 87 (3.) Diameter 82 (3.2) ST-H ultrasonic transducer, dimensions in mm (inch) Schematics Direct connection Black White Shield Coaxial extension White Shield 3 Terminal direct* Black White Shield 3 Terminal extension* Black White Shield * For SITRANS LUT00, MultiRanger 100/200, HydroRanger 200 ST-H ultrasonic transducer connections Siemens FI 01 June 2015 /173

174 Continuous level measurement - Ultrasonic transducers EchoMax XRS-5 Overview EchoMax XRS-5 ultrasonic transducer provides reliable, continuous level monitoring of liquids and slurries in narrow lift stations/ wet wells, flumes, weirs and filter beds using a beam angle of just 10 and a CSM rubber face. Benefits Narrow beam angle of only 10 Chemically resistant PVDF copolymer enclosure and CSM rubber face Measuring range: 8 m (26 ft) for measurement of liquids and slurries Fully submersible: IP68 degree of protection Easy installation with 1" NPT or R 1" BSPT connection Application The XRS-5 is non-contacting with a measuring range from m ( ft). Advanced echo processing ensures reliable data even in conditions with obstructions, turbulence and foam. The hermetically sealed CSM rubber face and the PVDF copolymer enclosure are designed for maximum resistance to methane, salt water, caustics and harsh chemicals common to wastewater installations. With an IP68 degree of protection, this rugged sensor is fully submersible in the event of flood conditions. Use a submergence shield if full submergence is possible in the application. A submergence shield will maintain a high level reading output during submerged conditions. The low-cost XRS-5 transducer is compatible with a full range of Siemens controllers, from a basic system for high/low alarm or simple pump control, up to advanced control systems with communications, telemetry and SCADA integration capabilities. Key Applications: wet wells, flumes, weirs, filter beds Technical specifications Mode of operation Measuring principle Input Measuring range Ultrasonic transducer m ( ft), dependent on application Output Frequency khz Beam angle 10 Accuracy Temperature error Compensated by integral temperature sensor Rated operating conditions Vessel pressure Normal atmospheric pressure Ambient conditions Ambient temperature C ( F) Design Weight (approximate shipping weight 1.2 kg (2.6 lb) of sensor with standard cable length) Material (enclosure) PVDF copolymer enclosure and CSM face Process connection 1" NPT [(Taper), ANSI/ASME B1.20.1] or R 1" [(BSPT), EN 10226] Degree of protection IP65/IP68 Cable connection 2-core shielded/twisted, 0.5 mm 2 (20 AWG), PVC sheath Cable (max. length) 365 m (1 200 ft) with RG 62 A/U coaxial cable 365 m (1 200 ft) with 2-core twisted pair, foil shield, 0.5 mm 2 (20 AWG), PVC sheath, only for MultiRanger 100/200 Options Flange version Factory flange with PTFE face for ASME, EN or JIS configuration Submergence shield For applications with flooding possible Certificates and approvals CE, RCM, KCC CSA Class I, Div. 2, Groups A,B,C,D, Class II, Div. 1 Groups E,F,G FM Class I, Zone 1, AEx m IIC, T6 Class II, III, Div. 1, Groups E,F,G T6 ATEX II 2GD / IECEx / INMETRO Ex mb IIC T6 Gb, Ex tb IIIC T85 C Db /17 Siemens FI 01 June 2015

175 Continuous level measurement - Ultrasonic transducers EchoMax XRS-5 EchoMax XRS-5 transducer With a beam angle of 10, the XRS-5 provides 7ML reliable, continuous level monitoring of liquids and slurries in narrow lift stations/wet wells, flumes, weirs and filter beds. Measuring range: min. 0.3 m (1 ft), max. 8 m (26 ft) Click on the for the online configuration in the PIA Life Cycle Portal. Process connection 1" NPT [(Taper), ANSI/ASME B1.20.1] 1 R 1" [(BSPT), EN 10226] 2 Cable length 5 m (16.0 ft) A 10 m (32.81 ft) B 30 m (98.3 ft) C Facing Standard (CSM rubber) A PTFE (flange versions) B Approvals CE, RCM, KCC, CSA Class I, Div. 2, Groups 2 A,B,C,D, Class II, Div. 1 Groups E,F,G FM Class I, Zone 1, AEx m IIC, T6 Class II, III, Div. 1, Groups E,F,G T6 ATEX II 2GD / IECEx / INMETRO Ex mb IIC T6 Gb, Ex tb IIIC T85 C Db Mounting flange (flush mount) None A 3" ASME, 150 lb, flat faced B " ASME, 150 lb, flat faced C 6" ASME, 150 lb, flat faced D DN 80, PN 10/16, Type A, flat faced J DN 100, PN 10/16, Type A, flat faced K DN 150, PN 10/16, Type A, flat faced L JIS10K 3B style Q JIS10K B style R JIS10K 6B style S Note: Flange bolting patterns and facings dimensionally correspond to the applicable ASME B16.5 or EN , or JIS B 2220 standard. Operating Instructions Quick Start Manual, multi-language A5E Applications Guidelines, multi-language 7ML1998-5HV61 Note: The Applications Guidelines should be ordered as a separate line item on the order. This device is shipped with the Siemens Milltronics manual DVD containing the ATEX Quick Start and Operating Instructions library. We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 9/5 in the appendix. Order code Further designs Please add "-Z" to and specify Order code(s). Acrylic coated, stainless steel tag [13 x 5 mm Y17 (0.5 x 1.75 inch)]: Measuring-point number/ identification (max. 16 characters) specify in plain text Accessories Tag, stainless steel with hole, 7ML1930-1BJ 12 x 5 mm (0.7 x 1.77 inch), one text line for fastening on sensors Submergence shield kit 7ML1830-1BH Easy Aimer 2, aluminum, NPT with ¾" x 1" PVC 7ML1830-1AQ coupling Easy Aimer 2, aluminum with M20 adapter and 7ML1830-1AX 1" and 1½" BSPT aluminum couplings Easy Aimer 30, NPT with 1" stainless steel 7ML1830-1AU coupling Easy Aimer 30, with M20 adapter and 1" and 7ML1830-1GN 1½" BSPT 30 stainless steel couplings FMS-200 universal box bracket, mounting kit 7ML1830-1BK FMS-210 channel bracket, wall mount 7ML1830-1BL FMS-220 extended channel bracket, wall mount 7ML1830-1BM FMS-310 channel bracket, floor mount 7ML1830-1BN FMS-320 extended channel bracket, floor mount 7ML1830-1BP FMS-350 bridge channel bracket, floor mount 7ML1830-1BQ (see Mounting Brackets on page /187 for more information) 1" NPT locknut, plastic 7ML1830-1DS 1" BSPT locknut, plastic 7ML1830-1DR We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 9/5 in the appendix. Siemens FI 01 June 2015 /175

176 Continuous level measurement - Ultrasonic transducers EchoMax XRS-5 EchoMax XRS-5C transducer 7ML1105- With a beam angle of 10, the XRS-5 provides reliable, continuous level monitoring of liquids and slurries in narrow lift stations/wet wells, flumes, weirs and filter beds. Measuring range: min. 0.3 m (1 ft), max. 8 m (26 ft) Click on the for the online configuration in the PIA Life Cycle Portal. Process connection 1" NPT [(Taper), ANSI/ASME B1.20.1] 1 Cable length 5 m (16.0 ft) A 10 m (32.81 ft) B 30 m (98.3 ft) C Facing Standard (CSM rubber) A PTFE (flange versions) B Approvals CSA Class I Div. 1, Groups A,B,C,D; Class II Div. 1, 1 Groups E,F,G; Class III Mounting flange (flush mount) None A 3" ASME, 150 lb, flat faced B " ASME, 150 lb, flat faced C 6" ASME, 150 lb, flat faced D Note: Flange bolting patterns and facings dimensionally correspond to the applicable ASME B16.5 or EN , or JIS B 2220 standard. Operating Instructions Quick Start Manual, multi-language A5E Applications Guidelines, multi-language 7ML1998-5HV61 Note: The Applications Guidelines should be ordered as a separate line item on the order. This device is shipped with the Siemens Milltronics manual DVD containing the ATEX Quick Start and Operating Instructions library. We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 9/5 in the appendix. Further designs Please add "-Z" to and specify Order code(s). Acrylic coated, stainless steel tag [13 x 5 mm (0.5 x 1.75 inch)]: Measuring-point number/ identification (max. 16 characters) specify in plain text Accessories Submergence shield kit Easy Aimer 2, aluminum, NPT with ¾" x 1" PVC coupling Easy Aimer 30, NPT with 1" stainless steel coupling FMS-200 universal box bracket, mounting kit FMS-210 channel bracket, wall mount FMS-220 extended channel bracket, wall mount FMS-310 channel bracket, floor mount FMS-320 extended channel bracket, floor mount FMS-350 bridge channel bracket, floor mount (see Mounting Brackets on page /187 for more information) Order code Y17 7ML1830-1BH 7ML1830-1AQ 7ML1830-1AU 7ML1830-1BK 7ML1830-1BL 7ML1830-1BM 7ML1830-1BN 7ML1830-1BP 7ML1830-1BQ We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 9/5 in the appendix. /176 Siemens FI 01 June 2015

177 Continuous level measurement - Ultrasonic transducers EchoMax XRS-5 Dimensional drawings Schematics Standard Submergence Shield (optional) Direct connection White/shield Black/hot 127 (5.0) 155 (6.1) 25 (0.98) Black White Shield 89 (3.5) Coaxial extension Flange (optional) 12 (.9) Junction box 127 (5.0) Extend cable using RG-62 A/U coax. ANSI, DIN, or JIS 3 terminal direct* Mounting: Suspended Conduit Rigid metal conduit Non-metallic coupling Bracket Flexible conduit Steel channel Non-metallic coupling Transducer 3 terminal extension* Black White Black White Shield Shield Flexible conduit transducer should not be subjected to wind, vibration or jarring. * For SITRANS LUT00, MultiRanger 100/200, HydroRanger 200 Plywood Submersible XRS-5 ultrasonic transducer connections Non-metallic coupling Rigid metal conduit Non-metallic coupling Submergence shield Plywood mounting provides excellent isolation (must be rigid). Transducer with submergence shield, used in applications where flooding is possible. XRS-5 ultrasonic transducer, dimensions in mm (inch) Siemens FI 01 June 2015 /177

178 Continuous level measurement - Ultrasonic transducers EchoMax XPS Overview EchoMax XPS transducers use ultrasonic technology to measure level in a wide range of liquids and solids. Benefits Integral temperature compensation Low ringing effect reduces blanking distance Optional foam facing for dusty applications Self-cleaning and low-maintenance Chemically resistant Hermetically sealed Application XPS transducers can be fully immersed, are resistant to steam and corrosive chemicals, and can be installed without flanges. The XPS series offers versions for various measuring ranges up to 30 m (100 ft) and up to a max. temperature of 95 C (203 F). During operation, the EchoMax transducers emit acoustic pulses in a narrow beam. The level monitor measures the propagation time between pulse emission and its reflection (echo) to calculate the distance. /178 Siemens FI 01 June 2015

179 Continuous level measurement - Ultrasonic transducers EchoMax XPS Technical specifications Input XPS-10 XPS-15 (standard and F models) XPS-30 Measuring range m Standard: ( ft) m ( ft) m ( ft) XPS-15F: m ( ft) Output Frequency khz khz 30 khz Beam angle Environmental Location Indoors/outdoors Ambient temperature C XPS-15F: ( F) C ( F) C ( F) Pollution degree Pressure 8 bar g (120 psi g) Flanged: 0.5 bar g (7.25 psi g) 8 bar g (120 psi g) Flanged: 0.5 bar g (7.25 psi g) 0.5 bar g (7.25 psi g) Flanged: 0.5 bar g (7.25 psi g) Design Weight 0.8 kg (1.8 lb) 1.3 kg (2.8 lb) Flanged: 2 kg (. lb).3 kg (9.5 lb) Power supply Operation of transducer only with approved Siemens Milltronics controllers Material Standard: PVDF Flanged: PVDF with CPVC flange Option: PTFE face with CPVC flange Standard: PVDF Flanged: PVDF with CPVC flange Option: PTFE face with CPVC flange Standard: PVDF Flanged: PVDF with CPVC flange Option: PTFE face with CPVC flange Color Blue Standard: Blue Blue XPS-15F: Gray Process connection 1" NPT or 1" BSPT Standard: 1.5" universal thread (NPT or BSPT) 1" NPT or 1" BSPT XPS-15F: 1" NPT Degree of protection IP66/68 IP66/68 IP66/68 Cable 2 wire twisted pair/braided and foil shielded 0.5 mm² (20 AWG) PVC jacket Separation Max. 365 m (1 200 ft) Certificates and approvals Standard: CE, CSA, FM, ATEX, IECEx Standard: CE, CSA, FM, ATEX, IECEx XPS-15F: FM Class I, Div. 1, Groups A, B, C and D, Class II Div. 1, Groups E, F and G, Class III CE, CSA, FM, ATEX, IECEx 1) EMC certificate available on request. Siemens FI 01 June 2015 /179

180 Continuous level measurement - Ultrasonic transducers EchoMax XPS EchoMax XPS-10 ultrasonic transducer High-frequency ultrasonic transducer designed for a wide variety of liquid and solid applications, 7ML for use with approved controllers. Includes integral temperature sensor. Measuring range: min. 0.3 m, max.10 m Click on the for the online configuration in the PIA Life Cycle Portal. Mounting thread and facing 1" NPT [(Taper), ANSI/ASME B1.20.1] 0 1" NPT [(Taper), ANSI/ASME B1.20.1] 1 with foam facing 1) 1" NPT [(Taper), ANSI/ASME B1.20.1] 2 with PTFE facing 2) R 1" [(BSPT), EN 10226] 3 R 1" [(BSPT), EN 10226] with foam facing 1) R 1" [(BSPT), EN 10226] with PTFE facing 2) 5 Cable length 5 m (16.0 ft) B 10 m (32.81 ft) C 30 m (98.3 ft) E 50 m (16.0 ft) F 100 m ( ft) K Mounting flange None A 3" ASME, 150 lb, flat faced C " ASME, 150 lb, flat faced D 6" ASME, 150 lb, flat faced E 8" ASME, 150 lb, flat faced F DN 80, PN 10/16, Type A, flat faced G DN 100, PN 10/16, Type A, flat faced J DN 150, PN 10/16, Type A, flat faced L JIS10K3B Style M JIS10KB Style P JIS10K6B Style R (Note: Flange bolting patterns and facings dimensionally correspond to the applicable ASME B16.5 or EN , or JIS B 2220 standard.) Approvals ATEX 2GD Ex mb IIC T Gb, Ex tb IIIC T135 C Db; 3 IECEx SIR X Ex mb IIC T Gb, Ex tb IIIC T135 C Db; FM Class I, Div. 2, Groups A,B,C,D; Class II, Div. 1, Groups E,F,G; Class III CSA Class I, Div. 1, Groups A,B,C,D, Class II, Div. 1, Groups E,F,G, Class III 3) 1) Not available with flanged versions 2) Available with flanged versions only 3) Valid with mounting thread and facing options only We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 9/5 in the appendix. Order code Further designs Please add "-Z" to and specify Order code(s). Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Y15 Measuring point number/ identification (max. 27 characters) specify in plain text Operating Instructions Quick Start guide, multi-language A5E Applications Guidelines, multi-language 7ML1998-5HV61 Note: The Applications Guidelines should be ordered as a separate line item on the order. This device is shipped with the Siemens Milltronics manual DVD containing the ATEX Quick Start and Operating Instructions library. Accessories Tag, stainless steel with hole, 12 x 5 mm 7ML1930-1BJ (0.7 x 1.77 inch), one text line for fastening on sensors Submergence shield kit 7ML1830-1BH Easy Aimer 2, aluminum, NPT with ¾" x 1" PVC 7ML1830-1AQ coupling Easy Aimer 2, aluminum with M20 adapter and 7ML1830-1AX 1" and 1½" BSPT aluminum couplings Easy Aimer 30, NPT with 1" stainless steel 7ML1830-1AU coupling Easy Aimer 30, with M20 adapter and 1" and 7ML1830-1GN 1½" BSPT 30 stainless steel couplings Universal box bracket, mounting kit 7ML1830-1BK Channel bracket, wall mount 7ML1830-1BL Extended channel bracket, wall mount 7ML1830-1BM Channel bracket, floor mount 7ML1830-1BN Extended channel bracket, floor mount 7ML1830-1BP Bridge channel bracket, floor mount 7ML1830-1BQ (see Mounting Brackets on page /187 for more information) 1" NPT locknut, plastic 7ML1830-1DS 1" BSPT locknut, plastic 7ML1830-1DR /180 Siemens FI 01 June 2015

181 Continuous level measurement - Ultrasonic transducers EchoMax XPS EchoMax XPS-15 ultrasonic transducer High-frequency ultrasonic transducer designed for a wide variety of liquid and solid applications, 7ML for use with approved controllers. Includes integral temperature sensor. Measuring range: min. 0.3 m, max. 15 m Click on the for the online configuration in the PIA Life Cycle Portal. Mounting thread and facing 1" NPT [(Taper), ANSI/ASME B1.20.1] 0 1" NPT [(Taper), ANSI/ASME B1.20.1] 1 with foam facing 1) 1" NPT [(Taper), ANSI/ASME B1.20.1] 2 with PTFE facing 2) R 1" [(BSPT), EN 10226] 3 R 1" [(BSPT), EN 10226] with foam facing 1) R 1" [(BSPT), EN 10226] with PTFE facing 2) 5 Cable length 5 m (16.0 ft) B 10 m (32.81 ft) C 30 m (98.3 ft) E 50 m (16.0 ft) F 100 m ( ft) K Mounting flange None A 6" ASME, 150 lb, flat faced D 8" ASME, 150 lb, flat faced E DN 150, PN 10/16, Type A, flat faced J DN 200, PN 10, Type A, flat faced K JIS10K 6B N JIS10K 8B (Note: Flange bolting patterns and facings dimensionally correspond to the applicable P ASME B16.5 or EN , or JIS B 2220 standard.) Approvals ATEX 2GD Ex mb IIC T Gb, Ex tb IIIC T135 C Db; 3 IECEx SIR X Ex mb IIC T Gb, Ex tb IIIC T135 C Db; FM Class I, Div. 2, Groups A,B,C,D; Class II, Div. 1, Groups E,F,G; Class III CSA Class I, Div. 1 Groups A,B,C,D, Class II, Div. 1, Groups E,F,G, Class III 3) 1) Not available with flanged versions 2) Available with flanged versions only 3) Available with mounting options only We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 9/5 in the appendix. Order code Further designs Please add "-Z" to and specify Order code(s). Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Y15 Measuring point number/ identification (max. 27 characters) specify in plain text Operating Instructions Quick Start guide, multi-language A5E Applications Guidelines, multi-language 7ML1998-5HV61 Note: The Applications Guidelines should be ordered as a separate line item on the order. This device is shipped with the Siemens Milltronics manual DVD containing the ATEX Quick Start and Operating Instructions library. Accessories Tag, stainless steel with hole, 12 x 5 mm 7ML1930-1BJ (0.7 x 1.77 inch), one text line for fastening on sensors Submergence shield kit 7ML1830-1BJ Universal box bracket, mounting kit 7ML1830-1BK Channel bracket, wall mount 7ML1830-1BL Extended channel bracket, wall mount 7ML1830-1BM Channel bracket, floor mount 7ML1830-1BN Extended channel bracket, floor mount 7ML1830-1BP Bridge channel bracket, floor mount 7ML1830-1BQ (see Mounting Brackets on page /187 for more information) 1" NPT locknut, plastic 7ML1830-1DS 1" BSPT locknut, plastic 7ML1830-1DR Easy Aimer 2, aluminum, NPT with ¾" x 1" PVC 7ML1830-1AQ coupling Easy Aimer 2, aluminum with M20 adapter and 7ML1830-1AX 1" and 1½" BSPT aluminum couplings Easy Aimer 30, NPT with 1" stainless steel 7ML1830-1AU coupling Easy Aimer 30, with M20 adapter and 1" and 1½" 7ML1830-1GN BSPT 30 stainless steel couplings We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 9/5 in the appendix. Siemens FI 01 June 2015 /181

182 Continuous level measurement - Ultrasonic transducers EchoMax XPS EchoMax XPS-15F ultrasonic transducer 7ML1171- High-frequency ultrasonic transducer designed 7 7 for a wide variety of liquid and solid applications, 770 for use with approved controllers. Includes integral temperature sensor. Measuring range: min. 0.3 m, max. 15 m Click on the for the online configuration in the PIA Life Cycle Portal. Mounting thread and facing 1" NPT [(Taper), ANSI/ASME B1.20.1] 1 Cable length 5 m (16.0 ft) B 10 m (32.81 ft) C 30 m (98.3 ft) D 50 m (16.0 ft) E 100 m ( ft) F Mounting flange, flush mount None A 6" ASME, 150 lb, flat faced B 8" ASME, 150 lb, flat faced C (Note: Flange bolting patterns and facings dimensionally correspond to the applicable ASME B16.5, or EN , or JIS B 2220 standard.) Approvals FM Class I, Div. 1, Groups A, B, C, and D, Class II 1 Div. 1, Groups E, F, and G, Class III Order code Further designs Please add "-Z" to and specify Order code(s). Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Y15 Measuring point number/ identification (max. 27 characters) specify in plain text Operating Instructions English A5E Applications Guidelines, multi-language 7ML1998-5HV61 Note: The Applications Guidelines should be ordered as a separate line item on the order. This device is shipped with the Siemens Milltronics manual DVD containing the ATEX Quick Start and Operating Instructions library. Accessories Tag, stainless steel with hole, 12 x 5 mm 7ML1930-1BJ (0.7 x 1.77 inch), one text line for fastening on sensors Submergence shield kit 7ML1830-1BJ Universal box bracket, mounting kit 7ML1830-1BK Channel bracket, wall mount 7ML1830-1BL Extended channel bracket, wall mount 7ML1830-1BM Channel bracket, floor mount 7ML1830-1BN Extended channel bracket, floor mount 7ML1830-1BP Bridge channel bracket, floor mount 7ML1830-1BQ (see Mounting Brackets on page /187 for more information) 1" NPT locknut, plastic 7ML1830-1DS Easy Aimer 2, aluminum, NPT with ¾" x 1" PVC 7ML1830-1AQ coupling Easy Aimer 30, NPT with 1" stainless steel 7ML1830-1AU coupling EchoMax XPS-30 ultrasonic transducer 7ML1123- High-frequency ultrasonic transducer designed 7 7 for a wide variety of liquid and solid applications, 770 for use with approved controllers. Includes integral temperature sensor. 1½" universal thread compatible with 1½" NPT and R 1½" [(BSPT), EN 10226] Measuring range: min. 0.6 m (1.97 ft), max. 30 m (98.3 ft) Click on the for the online configuration in the PIA Life Cycle Portal. Mounting thread and facing 1½" universal thread 0 1½" universal thread, foam facing 1) 1 1½" universal thread, PTFE facing 2) 2 Cable length 5 m (16.0 ft) B 10 m (32.81 ft) C 30 m (98.3 ft) E 50 m (16.0 ft) F 100 m ( ft) K Mounting flange None A 6" ASME, 150 lb, flat faced D 8" ASME, 150 lb, flat faced E DN 150, PN 10/16, Type A, flat faced J DN 200, PN 10, Type A, flat faced K JIS10K 6B N JIS10K 8B P (Note: Flange bolting patterns and facings dimensionally correspond to the applicable ASME B16.5 or EN , or JIS B 2220 standard.) Approvals ATEX 2G 1D Ex mb IIC T Gb, Ex ta IIIC T135 C 5 Da; IECEx SIR X Ex mb IIC T Gb, Ex ta IIIC T135 C Da 1) Not available with flanged versions 2) Available with flanged versions only Order code Further designs Please add "-Z" to and specify Order code(s). Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Y15 measuring-point number/identification (max. 27 characters) specify in plain text Operating Instructions Quick Start guide, multi-language A5E Applications Guidelines, multi-language 7ML1998-5HV61 Note: The Applications Guidelines should be ordered as a separate line item on the order. This device is shipped with the Siemens Milltronics manual DVD containing the ATEX Quick Start and Operating Instructions library. Accessories Tag, stainless steel with hole, 12 x 5 mm 7ML1930-1BJ (0.7 x 1.77 inch), one text line for fastening on sensors 1½" BSPT locknut, plastic 7ML1830-1DP Easy Aimer 2, aluminum, NPT with 1½" 7ML1830-1AN galvanized coupling Easy Aimer 30, NPT with 1½" stainless steel coupling 7ML1830-1AT Easy Aimer 2, aluminum with M20 adapter and 7ML1830-1AX 1" and 1½" BSPT aluminum couplings Easy Aimer 30, with M20 adapter and 1" and 7ML1830-1GN 1½" BSPT 30 stainless steel couplings /182 Siemens FI 01 June 2015

183 Continuous level measurement - Ultrasonic transducers EchoMax XPS EchoMax XPS-30C ultrasonic transducer High-frequency ultrasonic transducer designed for a wide variety of liquid and solid applications, for use with approved controllers. Includes integral temperature sensor. 1½" universal thread compatible with 1½" NPT and R 1½" [(BSPT), EN 10226] Measuring range: min. 0.6 m (1.97 ft), max. 30 m (98.3 ft) Click on the for the online configuration in the PIA Life Cycle Portal. 7ML Mounting thread and facing 1½" universal thread 0 1½" universal thread, foam facing 1) 1 1½" universal thread, PTFE facing 2) 2 Cable length 5 m (16.0 ft) B 10 m (32.81 ft) C 30 m (98.3 ft) E 50 m (16.0 ft) F 100 m ( ft) K Mounting flange None A 6" ASME, 150 lb, flat faced D 8" ASME, 150 lb, flat faced E DN 150, PN 10/16, Type A, flat faced J DN 200, PN 10, Type A, flat faced K JIS10K 6B N JIS10K 8B P (Note: Flange bolting patterns and facings dimensionally correspond to the applicable ASME B16.5 or EN , or JIS B 2220 standard.) Approvals CSA, Class I, Div. 2, Groups A,B,C,D; Class II, Div. 1, Groups E,F, G; Class III Order code Further designs Please add "-Z" to and specify Order code(s). Stainless steel tag [69 mm x 50 mm Y15 (2.71 x 1.97 inch)]: Measuring-point number / identification (max. 27 characters) specify in plain text Operating Instructions Quick Start guide, multi-language A5E Applications Guidelines, multi-language 7ML1998-5HV61 Note: The Applications Guidelines should be ordered as a separate line item on the order. This device is shipped with the Siemens Milltronics manual DVD containing the ATEX Quick Start and Operating Instructions library. Accessories Easy Aimer 2, aluminum, NPT with 1½" galvanized 7ML1830-1AN coupling Easy Aimer 30, NPT with 1½" stainless steel 7ML1830-1AT coupling 1½" BSPT locknut, plastic 7ML1830-1DP 1) Not available with flanged version 2) Available for flanged versions only Siemens FI 01 June 2015 /183

184 Continuous level measurement - Ultrasonic transducers EchoMax XPS Dimensional drawings Schematics Standard Submergence shield Direct connection F J B Black White Shield A Bonded flange Radiating face Coaxial connection White Shield B E 3 terminal direct* C XPS ultrasonic transducer, dimensions in mm (inch) Black Shield White Version Dimension XPS-10 XPS-15 XPS-30 A 88 mm (3.6 inch) 121 mm (.76 inch) 175 mm (6.890 inch) B C E F J 122 mm (.803 inch) 132 mm (5.197 inch) According to ASME, DIN and JIS 12 mm (.882 inch) 152 mm (5.98 inch) 28 mm (1.1 inch) 158 mm (6.220 inch) 198 mm (7.795 inch) 28 mm (1.1 inch) 198 mm (7.795 inch) n/a n/a 28 mm (1.1 inch) 3 terminal extension* Black White Shield * For SITRANS LUT00, MultiRanger 100/200, HydroRanger 200 Mounting Make particularly sure that the radiating face of the transducer is protected from damage. Mount the transducer so that it is above the maximum material level by at least the blanking value. On liquid applications, the transducer must be mounted so that the axis of transmission is perpendicular to the liquid surface. On solids applications, a Milltronics Easy Aimer should be used to facilitate aiming the transducer. Consider the optional temperature sensor when mounting the transducer. Interconnection Do not route cable openly or near high voltage or current runs, contactors and SCR control drives. For optimum isolation against electrical noise, run cable separately in a grounded metal conduit. Seal all thread connections to prevent ingress of moisture. XPS ultrasonic transducer connections /18 Siemens FI 01 June 2015

185 Application Application EA 30 aiming device EA 2 aiming device The Easy Aimer 30 flange is a stainless steel aiming device for alignment of Siemens ultrasonic transducers used for level measurement of bulk solids. The sensor must be mounted aimed towards the low level draw point in the silo. The sensor can be rotated through 360 and angled at 0 to 27 off vertical. It must be mounted using an access plate with welded studs or a flange in order to isolate the mounting holes from the pressurized environment. When installed properly, the EA 30 aiming device is capable of withstanding pressures up to 0.5 bar (Europe) or 15 psi (North America). It can even be used in corrosive and aggressive environments. Continuous level measurement - Accessories for ultrasonic EA aiming devices The Easy Aimer 2 flange is a cast aluminum aiming device for alignment of Siemens ultrasonic transducers. The flange has graduated adjustments and an adjustable insertion length. When used for applications with bulk solids, the sensor is mounted so that it is aimed towards the lower level draw point in the silo. The sensor can be rotated through 360 and angled at 0 to 20 off vertical. It must be mounted using an access plate with welded studs or a flange in order to isolate the mounting holes from the pressurized environment. When installed properly, the EA 2 aiming device is capable of withstanding pressures up to 0.5 bar (Europe) or 15 psi (North America). It can even be used in corrosive and aggressive environments. Dimensional drawings 170 (6.7) 135 (5.3) nominal 10 (0.38) Ø127 (5) typical 1" NPT or BSP Clamping plate (upper socket) Mounting block (lower socket) Customer gasket (as required) Customer mounting plate (as required) Coupling/adapter Siemens Milltronics transducer (typical) Dimensional drawings 76 (3) nominal Locknut Conduit gland 16 (0.63) 127 (5) Ø typical max 20 ¾ NPT or BSP conduit x 300 (12) long Coupling/ Adapter Angle block Sighting block Mounting block Customer gasket (as required) Customer mounting plate (as required) Siemens Milltronics Transducer (typical) máx. 27 Mounting hole - 3 places 11 (7/16) on 157 (6.2) bolt center diameter Ground screw MILLTR ONIC S Mounting hole - 3 places to suit M8 or ⅜ inch, 120 apart on 157 mm (6.2 inch) bolt center diameter Angle block binding screw and clamp Sighting block binding screw and clamp Clamping screw (3 places) EAS Y AIME R II 178 (7) EA 30 aiming device, dimensions in mm (inch) 178 (7.0) Ground screw EA 2 aiming device, dimensions in mm (inch) Siemens FI 01 June 2015 /185

186 Continuous level measurement - Accessories for ultrasonic EA aiming devices Easy aimer Used on solids applications to aim transducers for optimal performance. Available in a 30 stainless steel model, or a cast aluminum model. Easy Aimer 2, aluminum with M20 adapter and 1" and 1½" BSPT aluminum couplings Easy Aimer 30, with M20 adapter and 1" and 1½" BSPT 30 stainless steel couplings Easy Aimer 2, aluminum, BSPT conduit Easy Aimer 2, aluminum, NPT with 1½" galvanized coupling 1) Easy Aimer 2, aluminum, NPT with 1" galvanized coupling Easy Aimer 2, aluminum, NPT with ¾" x 1" PVC coupling Easy Aimer 30, BSPT conduit Easy Aimer 30, NPT with 1½" stainless steel coupling 1) Easy Aimer 30, NPT with 1" stainless steel coupling Operating Instructions Easy Aimer 2 and 30 Operating Instructions, Multi-language Note: The Operating Instructions should be ordered as a separate line item on the order. This device is shipped with the Siemens Milltronics manual DVD containing the Quick Start and Operating Instructions library. 1) For use with XPS-30 transducers only 7ML1830-1AX 7ML1830-1GN 7ML1830-1AL 7ML1830-1AN 7ML1830-1AP 7ML1830-1AQ 7ML1830-1AS 7ML1830-1AT 7ML1830-1AU 7ML1998-5HG62 /186 Siemens FI 01 June 2015

187 Continuous level measurement - Accessories for ultrasonic FMS mounting brackets Application Integration Siemens mounting brackets permit simple, fast installation of ultrasonic transducers. These rugged, high quality mounting brackets are constructed of 30 (1.301) stainless steel and are suitable for use indoors and outdoors. They adjust to fit almost any application, saving you the time and expense of building custom brackets. Each kit includes all mounting parts. FMS-200 universal box bracket system Mounting of units with 1 inch or 2 inch threaded connection. Distance from sensor to wall or beam: cm ( inch). The unique box design also acts as a sun shield for transducers with 1 inch threaded connections. FMS-210 wall mounting set Mounting of transducers with 1 inch threaded connection. Distance from transducer to wall or beam: cm ( inch). FMS-220 extended wall mounting set Mounting of transducers with 1 inch threaded connection. Distance from transducer to wall or beam: cm ( inch). FMS-310 floor mounting set Mounting of transducers with 1 inch threaded connection. Distance from transducer to floor: cm ( inch). Distance from mounting support: cm ( inch). FMS-320 extended floor mounting set Mounting of transducers with 1 inch threaded connection. Distance from transducer to floor: cm ( inch). Distance from mounting support: cm ( inch). FMS-350 floor mounting set, bridge Mounting of transducers with 1 inch threaded connection. Distance from transducer to floor: cm ( inch), anywhere along the complete width of the bridge [166 cm (65 inch)]. This kit is particularly suitable for measurements on open channels (OCM) by providing a very stable mount for the transducer above a flume or weir. FMS-310 Channel bracket, floor mount FMS-200 Universal box bracket FMS-210 Channel bracket, wall mount FMS-320 Extended channel bracket, floor mount FMS-220 Extended channel bracket, wall mount FMS-350 Bridge channel bracket, floor mount FMS mounting brackets Siemens FI 01 June 2015 /187

188 Continuous level measurement - Accessories for ultrasonic FMS mounting brackets Mounting brackets for XPS-10 sensors FMS-200 universal box bracket set FMS-210 wall mounting set FMS-220 extended wall mounting set FMS-310 floor mounting set FMS-320 extended floor mounting set FMS-350 floor mounting set, bridge Additional Operating Instructions FMS-200 FMS-210 FMS-220 FMS-310 FMS-320 FMS-350 Note: The Operating Instructions should be ordered as a separate line item on the order. 7ML1830-1BK 7ML1830-1BL 7ML1830-1BM 7ML1830-1BN 7ML1830-1BP 7ML1830-1BQ 7ML1998-5BK61 7ML1998-5BL61 7ML1998-5BM61 7ML1998-5BN61 7ML1998-5BP61 7ML1998-5BQ61 /188 Siemens FI 01 June 2015

189 Continuous level measurement - Accessories for ultrasonic TS-3 temperature sensor Overview Design Clearance Conduit (supplied by others) Coupling (supplied by others) TS-3 Plate or wall The TS-3 temperature sensor provides an input signal for temperature compensation of specific Siemens ultrasonic level controllers. Benefits Chemically resistant ETFE enclosure Fast response time Approved for use in potentially explosive atmospheres Application Temperature compensation is essential in applications where temperature variations of the sound medium are expected. By installing the temperature sensor close to the sound path of the associated ultrasonic transducer, a signal representative of the sound medium s ambient temperature is obtained. The temperature sensor should not be mounted in direct sunlight. The TS-3 is used in conjunction with ultrasonic transducers that do not have an integral temperature sensor. It is also recommended in cases where the integral temperature sensor of the transducer cannot be used. The following conditions are typical for use of the TS-3 sensor: where a fast reaction to temperature variations is required, where a flanged ultrasonic transducer is used, or where high temperatures are encountered. The TS-3 is not compatible with devices using the TS-2 or LTS-1 temperature sensors. Refer to the associated controller manual for more details. Key Applications: For use in applications where temperature sensor measurement from transducer does not accurately represent vessel temperature. Used for applications requiring quick temperature response (open channel monitoring). Tapped Locknut (supplied by others) Note: Clearance hole/ locknut Installation method is not suitable for pressure applications. Flange or wall TS-3 temperature sensor Siemens FI 01 June 2015 /189

190 Continuous level measurement - Accessories for ultrasonic TS-3 temperature sensor Technical specifications Mode of operation Measuring principle Temperature sensor Input Measuring range C ( F) Output Response time Forced circulation (temperature variation: 63 %) 55 s Flange, forced circulation 90 s Natural convection 150 s Rated operating conditions Installation instructions Mounted indoors/outdoors, but not exposed to direct sunlight Pressure Max. bar (60 psi/00 kpa) Design Material (enclosure) ETFE 1) Cable connection 2-core, 0.5 mm² (20 AWG), shielded, silicone sheath Process connection ¾" NPT [(Taper), ANSI/ASME B1.20.1] R ¾" [(BSPT), EN 10226], totally encapsulated Certificates and approvals CE, IEC Ex, FM, CSA, ATEX 1) ETFE is a fluoropolymer inert to most chemicals. For exposure to specific environments, check the chemical compatibility charts before installing the TS-3 in your application. Dimensional drawings Refer to associated manual for terminal block detail SITRANS LUT00 only B W L HT K W HT B LK S H L D OR TS-3 temperature sensor 7ML1813- TS-3 provides an input signal for temperature 7 7 B 7 compensation of specific Siemens ultrasonic level controllers. Compensation is essential in applications where variation in temperature of the sound medium is expected. Click on the for the online configuration in the PIA Life Cycle Portal. Cable length 1 m (3.28 ft) 1 5 m (16.0 ft) 2 10 m (32.81 ft) 3 30 m (98.3 ft) 50 m (16.0 ft) 5 70 m ( ft) 6 90 m ( ft) 7 Process connection ¾" NPT [(Taper), ANSI/ASME B1.20.1] A R ¾" [(BSPT), EN 10226] B Approvals CSA, FM 3 CE, ATEX, IEC Ex Operating Instructions English A5E German A5E Note: The Operating Instructions should be ordered as a separate line item on the order. This device is shipped with the Siemens Milltronics manual DVD containing ATEX Quick Starts and Operating Instructions. Accessories ¾" NPT locknut, aluminum 7ML1930-1BE Tag, stainless steel with hole, 12 x 5 mm 7ML1930-1BJ (0.7 x 1.77 inch) for fastening on sensors Cable (0.6) (0.8) Connect direct or via customer junction box 15 (0.6) 136 (5.) 76 (3.0) ¾" NPT or BSP (2 places) Hex hub 27 (1 1/16) TS-3 temperature sensor, dimensions in mm (inch) /190 Siemens FI 01 June 2015

191 Continuous level measurement - Radar transmitters Radar transmitters Overview Mode of operation Radar measurement technology is non-contacting and low Principle of Operation maintenance. Because microwaves require no carrier medium, they are virtually unaffected by the process atmosphere (vapor, pressure, dust, or temperature extremes). Siemens offers a variety of models to meet the specific needs of your application. SITRANS Probe LR is a 2-wire, 6 GHz pulse radar level transmitter for continuous monitoring of liquids and slurries in storage vessels with nominal pressure and temperature, to a range of 20 m (66 ft). SITRANS LR200 is a 2-wire, 6 GHz pulse radar level transmitter for continuous monitoring of liquids and slurries in process vessels including high temperature, pressure, agitation, and turbulence to a range of 20 m (65 ft). SITRANS LR250 is a 2-wire, 25 GHz pulse radar level transmitter for continuous monitoring of liquids and slurries in storage and process vessels including high temperature and pressure, corrosive or aggressive materials, to a range of 20 m (66 ft). Ideal for small vessels and low dielectric media. SITRANS LR260 is a 2-wire, 25 GHz pulse radar level transmitter for continuous monitoring of solids in silos to a range of 30 m (98. ft). Ideal for applications with extreme dust and high temperatures to 200 C (392 F) and liquids in vessels. SITRANS LR60 is a -wire, 2 GHz FMCW radar level transmitter with extremely high signal to noise ratio and advanced signal processing for continuous monitoring of solids up to 100 m (328 ft). It is ideal for measurement in extreme dust. SITRANS LR560 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids in silos to a range of 100 m (329 ft). Auto False-Echo Suppression SITRANS LR instruments offer the unique advantage of Process Intelligence signal processing technology. This in-depth knowledge and experience is built into the software s advanced algorithms to provide intelligent processing of echo profiles. The result is repeatable, fast and reliable measurement. A special feature of SITRANS radar devices is Auto False-Echo Suppression, an echo processing technique that automatically detects and suppresses false echoes from vessel obstructions. You can implement this feature using two parameters on the local interface or SIMATIC PDM communicating over HART or PROFIBUS PA. Radar measurement technology measures the time of flight from the transmitted signal to the return signal. From this time, distance measurement and level are determined. Unlike ultrasonic measurement, radar technology does not require a carrier medium and travels at the speed of light ( m/s). Most industrial radar devices operate from 6 to 26 GHz. Siemens offers pulse radar transmitters (SITRANS Probe LR, SITRANS LR200, SITRANS LR250, SITRANS LR260) and FMCW (Frequency Modulated Continuous Wave) radar transmitters (SITRANS LR60, SITRANS LR560). Pulse radar emits a microwave pulse from the antenna at a fixed repetition rate that reflects off the interface between the two materials with different dielectric constants (the atmosphere and the material being monitored). The echo is detected by a receiver and the transmit time is used to calculate level. Reflected echoes are digitally converted to an echo profile. The profile is analyzed to determine the distance from the material surface to the reference point on the instrument. FMCW (Frequency Modulated Continuous Wave) radar devices send microwaves to the surface of the material. The wave frequency is modulated continuously. At the same time, the receiver is also receiving continuously and the difference in frequency between the transmitter and the receiver is directly proportional to the distance to the material. Level (db) Echo from agitator Surface echo Local display interface graphically displays echo profiles and diagnostic information (available with LR200, LR250, LR260 and LR560) Quick to configure Quick Start Wizard via SIMATIC PDM guides you during setup (available with LR200, LR250, LR260, LR60, LR560) Distance Radar operation in a reactor vessel Siemens FI 01 June 2015 /191

192 Continuous level measurement - Radar transmitters Radar transmitters Technical specifications Radar Selection Guide Criteria Typical industries Typical applications Range Frequency Performance accuracy Temperature SITRANS Probe LR Chemicals, petrochemicals, water/ waste-water, drilling mud Liquids, storage vessels, wet wells, and drilling mud tanks m ( ft) 5.8 GHz (North America 6.3 GHz) 0.1 % of range or 10 mm (0. inch) Ambient: C ( F) Process: C ( F 50 mm (2 inch) from end of horn to 20 m (65 ft), horn dependent K-band (25.0 GHz) Output/communications/remote configu- SIMATIC PDM ma/hart ration and diagnostics Power Approvals 2 V DC nominal Loop powered CE, RCM, Lloyds Register of Shipping, ABS, FCC, Industry Canada, R&TTE ATEX, CSA, FM, INMETRO, GOST-R, IECEx, ANZEx, TIIS SITRANS LR200 SITRANS LR250 SITRANS LR260 SITRANS LR60 SITRANS LR560 Chemicals, petrochemicals, aluminum, chemicals, and oil Chemicals, petro- wastewater and gas, mining, marine, food and beverage, and pharmaceutical Liquids, process vessels with agitators, build-up, and high temperatures m ( ft) 5.8 GHz (North America 6.3 GHz) 0.1 % of range or 10 mm (0. inch) Ambient: C ( F) Process: C ( F), dependent on antenna type...20ma/hart PROFIBUS PA SIMATIC PDM AMS SITRANS DTM/FDT for PACTware, Fieldcare, etc. 2 V DC nominal Loop powered CE, RCM, Lloyds Register of Shipping, ABS, FCC, Industry Canada, R&TTE ATEX, CSA, FM, INMETRO, GOST-R, IECEx, ANZEx, TIIS, NEPSI Liquids, storage and process vessels with agitators, vaporous liquids, high temperatures, low dielectric media, and crude oil produced water 3 mm (0.118 inch) Ambient: C ( F) Process: C ( F) dependent on antenna type...20ma/hart PROFIBUS PA FOUNDATION Fieldbus SIMATIC PDM AMS SITRANS DTM/FDT for PACTware, Fieldcare, etc. 2 V DC nominal Loop powered CE, RCM, Lloyds Register of Shipping, ABS, BV, FCC, Industry Canada, R&TTE ATEX, CSA, FM, INMETRO, GOST-R, IECEx, TIIS, NEPSI Functional safety SIL 2, EHEDG, 3-A, USP Class VI Cement, power generation, petrochemical, food processing, mineral processing, mining Cement, plastics, grain, flour, coal, liquids < 20 m, and low dielectric liquids <30m Cement, power generation, food processing, mineral processing, mining Cement, fly ash, grain, coal, flour, plastics Cement, power generation, food processing, mineral processing, mining Cement, fly ash, grain, coal, flour, plastics 30 m (98. ft) 100 m (328 ft) 0 m (131 ft) 100 m (328 ft) K-band (25.0 GHz) 25 mm (1 inch) from minimum detectable distance to 300 mm (11.8 inch) Remainder of range = 10 mm (0.39 inch) or 0.1 % of span (whichever is greater) Ambient: C ( F) Process: C ( F) dependent on antenna type...20ma/hart PROFIBUS PA SIMATIC PDM 2 V DC nominal Loop powered CE, RCM, FCC, Industry Canada, R&TTE ATEX, CSA, FM, INMETRO, GOST, IECEx GHz FMCW GHz 0.25 % 0.25 % Ambient: 65 C (19 F) Process: 200 C (392 F)...20mA/HART PROFIBUS PA SIMATIC PDM V AC, ±15 %, 50/60 Hz, 6 W 2 V DC, +25/-20 %, 6 W CE, RCM, FCC, Industry Canada, R&TTE ATEX, CSA, FM, INMETRO, IECEx, GOST Ambient: C ( F) Process: C ( F) Optional: 200 C (392 F)...20mA/HART PROFIBUS PA FOUNDATION Fieldbus SIMATIC PDM AMS SITRANS DTM/FDT for PACTware, Fieldcare, etc. 2 V DC nominal Loop powered CE, RCM, FCC, Industry Canada, R&TTE ATEX, CSA, FM, INMETRO, IECEx, NEPSI, GOST /192 Siemens FI 01 June 2015

193 SITRANS LR 00 Siemens AG 2015 Continuous level measurement - Radar transmitters Radar transmitters Application Radar Application Questionnaire Customer information Contact: Prepared By: Company: Date: Address: Notes on the Application: City: Zip/Postal Code: Country: Phone: ( ) Fax: ( ) Vessel Information Sketch attached Storage Solids Storage Liquids Process Reactor Area safety classification: (specify code required) Height: Top: m/ft Diameter: Atmosphere: (indicate all that apply) m/ft Filling method: Pressure: Flat Foam Steam Normal: Parabolic Dust Deposit (build-up) Maximum (relief): Conical Vapor Mounting connection (specify type) Critical Information Distance to sidewall: Mounting connection maximum temperature: Max. temperature at electronics: cm/inch C/ F C/ F Nozzle Length: Nozzle Diameter: cm/inch cm/inch Stilling well or Still Pipe mounting: Yes No Stilling well diameter: cm/inch Material Material being measured: Liquid Solid Liquified gas Material temperature: Material surface: Installation Norm: C/ F Max: C/ F Flat Tu Agitated Vortex Dielectric constant: r < r > Communications: Power available: Products recommended: Siemens Milltronics Process Instruments Inc. HART / ma PROFIBUS PA FOUNDATION Fieldbus None Update 03/2015 Siemens FI 01 June 2015 /193

194 Continuous level measurement - Radar transmitters SITRANS Probe LR Overview Configuration Installation Min. 300 mm (1 ft) for every 3 m (10 ft) of vessel wall. Beam angle 28 SITRANS Probe LR is a 2-wire, 6 GHz pulse radar level transmitter for continuous monitoring of liquids and slurries in storage vessels with nominal pressure and temperature, to a range of 20 m (66 ft). Benefits Uni-Construction polypropylene rod antenna standard Easy installation and simple start up Programming using infrared Intrinsically Safe handheld programmer, SIMATIC PDM or HART handheld communicator Communication using HART Process Intelligence signal processing Extremely high signal-to-noise ratio Auto False-Echo Suppression of false echoes Mounting unit on vessel Conical Flat Mounting on a manhole cover Parabolic Mounting on a nozzle Application The Probe LR is ideal for applications with chemical vapors, temperature gradients, vacuum or pressure, such as simple chemical storage or water treatment vessels. SITRANS Probe LR has a range of 0.3 to 20 m (1 to 65 ft). Probe LR is designed for safe and simple programming using the Intrinsically Safe handheld programmer without having to open the instrument s lid. It has a standard Uni-Construction polypropylene rod antenna that offers excellent chemical resistance and is hermetically sealed. The Uni-Construction antenna includes an internal, integrated shield that eliminates vessel nozzle interference. SITRANS Probe LR incorporates Process Intelligence signal processing. The Probe LR also has a high signal-to-noise ratio leading to improved reliability. Start-up is easy with as few as two parameters for basic operation. Programming is simple using SIMATIC PDM, HART handheld communicator or the Intrinsically Safe handheld programmer. Key Applications: chemical storage, wastewater wet well, and drilling mud Min. 100 () SITRANS Probe LR installation, dimensions in mm (inch) Min. 10 (0.) SITRANS Probe LR shield length 100 () or 250 (10) standard lengths /19 Siemens FI 01 June 2015

195 Continuous level measurement - Radar transmitters SITRANS Probe LR Technical specifications Mode of operation Measuring principle Frequency Measuring range Output Analog output Accuracy Span Communications Performance (reference conditions) Accuracy Influence of ambient temperature Repeatability Fail-safe Pulse radar level measurement 5.8 GHz (North America 6.3 GHz) m ( ft) ma ± 0.02 ma Proportional or inversely proportional HART ± the greater of 0.1 % of range or 10 mm (0. inch) %/K ± 5 mm (2 inch) ma signal programmable as high, low or hold (LOE) Rated operating conditions Installation conditions Location Indoor/outdoor Ambient conditions (enclosure) Ambient temperature C ( F) Installation category I Pollution degree Medium conditions Dielectric constant ε r ε r > 1.6 (for ε r < 3, use stillpipe) Vessel temperature C ( F) Vessel pressure 3 bar g (3.5 psi g) Design Enclosure Body construction PBT (Polybutylene Terephthalate) Lid construction PEI (Polyether Imide) Cable inlet 2 x M20x1.5 or 2 x ½" NPT with adapter Degree of protection Type X/NEMA X, Type 6/NEMA 6, IP67, IP68 Weight 1.97 kg (.35 lb) Antenna Material Polypropylene rod, hermetically sealed construction Dimensions Standard 100 mm ( inch) shield for maximum 100 mm ( inch) nozzle or optional 250 mm (10 inch) long shield Process connections 1½" NPT [(Taper), ANSI/ASME B1.20.1] R 1½" [(BSPT), EN 10226] G 1½" [(BSPP), EN ISO 228-1] Power supply Nominal 2 V DC with max. 550 Ω, maximum 30 V DC ma Certificates and approvals General CSA US/C, CE, FM, RCM Marine Lloyd's Register of Shipping ABS Type Approval Radio FCC, Industry Canada and European (R&TTE), RCM Hazardous Intrinsically Safe (Brazil) INMETRO Ex ia IIC T Ga Intrinsically Safe (Canada) CSA Class I, Div.1, Groups A,B,C,D; Class II, Div. 1, Group G; Class III Intrinsically Safe (Europe) ATEX II 1G EEx ia IIC T Intrinsically Safe (International) IECEx Ex ia IIC T Intrinsically Safe (Russia) GOST-R Ex ia Intrinsically Safe (USA) FM Class I, Div.1, Groups A,B,C,D; Class II, Div. 1, Groups E,F, G; Class III Programming Handheld programmer HART communicator 375 PC SIMATIC PDM Intrinsically safe Siemens handheld Infrared receiver programmer (optional) Approvals (handheld programmer) ATEX II 1G EEx ia IIC T CSA and FM Class I, Div.1, Groups A,B,C,D, T6 at max. ambient Display (local) Multi-segment alphanumeric liquid crystal with bar graph (representing level) available in four languages Siemens FI 01 June 2015 /195

196 Continuous level measurement - Radar transmitters SITRANS Probe LR SITRANS Probe LR 7ML530-2-wire, 6 GHz pulse radar level transmitter for continuous monitoring of liquids and slurries in storage vessels with nominal pressure and temperature, to a range of 20 m (66 ft). Max. 3 bar g (3.5 psi g) pressure and 80 C (176 F) Click on the for the online configuration in the PIA Life Cycle Portal. Enclosure/Cable inlet Plastic, (PBT), 2 x ½" NPT 1 Plastic, (PBT), 2 x M20x1.5 2 Antenna type/material - (max. 3 bar and 80 C) Polyproylene Antenna 1½" NPT [(Taper), ANSI/ASME B1.20.1], A comes with integral 100 mm shield R 1½" [(BSPT), EN 10226], B comes with integral 100 mm shield G 1½" [(BSPP), EN ISO 228-1], C comes with integral 100 mm shield 1½" NPT [(Taper), ANSI/ASME B1.20.1], D comes with integral 250 mm shield R 1½" [(BSPT), EN 10226], E comes with integral 250 mm shield G 1½" [(BSPP), EN ISO 228-1], F comes with integral 250 mm shield Approvals General Purpose, CE, R&TTE, RCM A General Purpose, CSA us/c, FM, FCC B CSA Class I, Div. 1, Groups A, B, C, D, Class II, Div. 1 Group G, Class III, FCC, Intrinsically Safe C FM, Class I, II and III, Div. 1, Groups A, B, C, D, E, F, G, D FCC, Intrinsically Safe IECEx Ex ia IIC T; ATEX II 1G EEx ia IIC T, E R&TTE, RCM, Intrinsically Safe; INMETRO Ex ia IIC T Ga; GOST-R Communication/Output ma, HART 1 We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 9/5 in the appendix. Order code Further designs Please add "-Z" to and specify Order code(s). Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Y15 Measuring-point number/identification (max. 27 characters) specify in plain text Manufacturer's test certificate: M to DIN 55350, C11 Part 18 and to ISO 9000 Operating Instructions English A5E French 7ML1998-5HR11 Spanish 7ML1998-5HR21 German A5E Note: The Operating Instructions should be ordered as a separate item on the order. This device is shipped with the Siemens Milltronics manual DVD containing the ATEX Quick Start and Operating Instructions library. Additional Operating Instructions Multi-language Quick Start manual A5E Accessories Handheld programmer, Intrinsically Safe, 7ML5830-2AH ATEX II 1G, Ex ia HART modem/usb 7MF997-1DB (for use with a PC and SIMATIC PDM) One metallic cable gland M20x1.5, 7ML1930-1AP rated C ( F) SITRANS RD100, loop powered display - 7ML see Chapter 7 SITRANS RD200, universal input display with 7ML Modbus conversion - see Chapter 7 SITRANS RD300, dual line display with totalizer 7ML and linearization curve and Modbus conversion - see Chapter 7 SITRANS RD500 web, universal remote monitoring 7ML solution for instrumentation - see Chapter 7 For applicable back up point level switch - see point level measurement section Spare parts Plastic lid 7ML1830-1KB For applicable back up point level switch - see point level measurement section We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 9/5 in the appendix. /196 Siemens FI 01 June 2015

197 Continuous level measurement - Radar transmitters SITRANS Probe LR Dimensional drawings ½" NPT cable entry (or alternatively M20 x 1.5) Lid Lid screws 129 (5.1) 139 (5.5) Std.: 552 (21.7) min. Option: 702 (27.6) max. Std.: 273 (10.8) min. Option: 23 (16.7) max. 13 (5.3) Enclosure/ electronics Locking collar Mounting thread 1½" NPT, R 1½" BSPT, 23 (0.9) G 1½" BSPP Inactive shield length (internal) Standard: 100 () Optional: 250 (10) Polypropylene rod antenna () Std. 115 (.5) [Optional 268 (10.5)] SITRANS Probe LR, dimensions in mm (inch) Schematics Connect the wires to the terminals as shown: the polarity is identified on the terminal block. Hand Programmer Strain relief (or NPT cable inlet) SITRANS Probe LR Part number: 7ML5830-2AH Notes: - DC terminal shall be supplied from an SELV source in accordance with IEC Annex H. - All field wiring must have insulation suitable for rated input voltages. - Use shielded twisted pair cable (1-22 AWG) - Separate cables and conduit may be required to conform to standard instrumentation wiring practices or electrical codes. SITRANS Probe LR connections Siemens FI 01 June 2015 /197

198 Continuous level measurement - Radar transmitters SITRANS LR200 Overview Configuration Installation Min. 300 mm (1 ft) for every 3 m (10 ft) of vessel wall. SITRANS LR200 is a 2-wire, 6 GHz pulse radar level transmitter for continuous monitoring of liquids and slurries in process vessels including high temperature, pressure, agitation, and turbulence to a range of 20 m (65 ft). Note: Beam angle is the width of the cone where the energy density is half of the peak energy density. Beam angle for horn antenna dependent on horn size The peak energy density is directly in front of and in line with the rod antenna. There is a signal transmitted outside of the beam angle; therefore false targets may be detected. Mounting unit on vessel Beam angle 28 Benefits Graphical local user interface (LUI) makes operation simple with plug-and-play setup using the intuitive Quick Start Wizard LUI displays echo profiles for diagnostic support Communication using HART or PROFIBUS PA Process Intelligence signal processing for improved measurement reliability and Auto False-Echo Suppression of fixed obstructions Programming using infrared Intrinsically Safe handheld programmer or SIMATIC PDM Application SITRANS LR200 s unique design allows safe and simple programming using the Intrinsically Safe handheld programmer without having to open the instrument s lid. It also features a built-in alphanumeric display in four languages. The SITRANS LR200 has a standard Uni-Construction polypropylene rod antenna that offers excellent chemical resistance and is hermetically sealed. The Uni-Construction antenna features an internal, integrated shield that eliminates vessel nozzle interference. Start-up is easy with as few as two parameters for basic operation. Installation is simplified as the electronics are mounted on a rotating head that swivels, allowing the instrument to line up with conduit or wiring connections or simply to adjust the position for easy viewing. SITRANS LR200 features Process Intelligence signal-processing technology for superior reliability. Key Applications: liquid process vessels with agitators, vaporous liquids, high temperatures, asphalt, digesters Conical Mounting unit on stilling well Flat Orient front or back of device toward stillpipe slots. SITRANS LR200 installation, dimensions in mm (inch) Parabolic Mounting on a nozzle Min. 10 (0.) /198 Siemens FI 01 June 2015

199 Continuous level measurement - Radar transmitters SITRANS LR200 Technical specifications Mode of operation Measuring principle Radar level measurement Frequency 5.8 GHz (North America 6.3 GHz) Measuring range m ( ft) Output Analog output ma Accuracy ± 0.02 ma Span Proportional or inversely proportional Communications HART Optional: PROFIBUS PA (Profile 3.0, Class B) Fail-safe Programmable as high, low or hold (Loss of Echo) Performance (according to reference conditions IEC ) From end of antenna to 600 mm: 0 mm (1.57 inch) Remainder of range: 10 mm (0. inch) or 0.1 % of span (whichever is greater) Rated operating conditions Installation conditions Location Indoor/outdoor Ambient conditions (enclosure) Ambient temperature C ( F) Installation category I Pollution degree Medium conditions Dielectric constant ε r ε r >1.6 (for ε r < 3, use stillpipe) Vessel temperature and pressure Varies with connection type; see Pressure/Temperature curves for more information Design Enclosure Material Aluminum, polyester powder coated Cable inlet 2 x M20x1.5 or 2 x ½" NPT with adapter Degree of protection Type X/NEMA X, Type 6/ NEMA 6, IP67, IP68 Weight < 2.82 kg (6.21 lb) (polypropylene rod antenna) Display (local) Multi-segment alphanumeric liquid crystal with bar graph (representing level) available in four languages Antenna Material Polypropylene rod, hermetically sealed construction, optional PTFE Dimensions Standard 100 mm ( inch) shield for maximum 100 mm ( inch) nozzle, or optional 250 mm (10 inch) long shield Optional rods and horn Refer to SITRANS LR200 Antennas for optional rods and horns Process connections Process connection Flange connection 1½" NPT [(Taper), ANSI/ASME B1.20.1] R 1½" [(BSPT), EN 10226], or G 1½" [(BSPP), EN ISO 228-1] (polypropylene rod antenna) Refer to SITRANS LR200 Antennas for more connections Power supply ma/hart General Purpose, Non-incendive, Nominal 2 V DC (max. 30 V DC) with Intrinsically Safe max. 550 Ω Flame proof, Increased safety, Nominal 2 V DC (max. 30 V DC) with Explosion proof max. 250 Ω PROFIBUS PA 10.5 ma Per IEC Certificates and approvals General CSA US/C, CE, FM, RCM Marine Lloyd s Register of Shipping ABS Type Approval Radio FCC, Industry Canada and European (R&TTE), RCM Hazardous Intrinsically Safe (Brazil) INMETRO Ex ia IIC T Ga Explosion Proof (Canada/USA) CSA/FM, Class I, Div. 1, Groups A, B, C, D; Class II, Div. 1, Groups E, F, G; Class III, T Intrinsically Safe (Canada/USA) CSA/FM, Class I, Div. 1, Groups A, B, C, D; Class II, Div. 1, Groups E, F, G; Class III, T Non-incendive (USA) FM, Class I, Div. 2, Groups A, B, C, D, T5 Flame Proof/Increased Safety NEPSI Ex d mb ia IIC T/ Ex e mb ia (China) IIC T Flame Proof (Europe) ATEX II 1/2 G Ex d mb ia IIC T Ga/Gb Increased Safety (Europe) ATEX II 1/2 G Ex e mb ia IIC T Ga/Gb Intrinsically Safe (Europe) ATEX II 1G Ex ia IIC T Intrinsically Safe (International) IECEx Ex ia IIC T Intrinsically Safe (Russia) GOST-R Ex ia Programming Intrinsically Safe Siemens handheld Infrared receiver programmer Approvals for handheld programmer IS model: ATEX II 1GD Ex ia IIC T Ga Ex iad 20 T135 C T a = C CSA/FM Class I, II, and III, Div. 1, Groups A, B, C, D, E, F, G, T6 T a = +50 C Handheld communicator HART communicator 375 PC SIMATIC PDM AMS Display (local) Multi-segment alphanumeric liquid crystal with bar graph (representing level) available in four languages Siemens FI 01 June 2015 /199

200 Continuous level measurement - Radar transmitters SITRANS LR200 SITRANS LR200, Uni-Construction 7ML522- polypropylene rod antenna version wire, 6 GHz pulse radar level transmitter for continuous monitoring of liquids and slurries in process vessels including high temperature and pressure, to a range of 20 m (66 ft). Max. 3 bar g (3.5 psi g) pressure and 80 C (176 F) Click on the for the online configuration in the PIA Life Cycle Portal. Enclosure/Cable inlet Aluminum, epoxy painted 2 x ½" NPT 2 2 x M20x1.5 3 Polypropylene antenna type - (Max. 3 Bar pressure and 80 C) 1½" NPT [(Taper), ANSI/ASME B1.20.1], A c/w integral 100 mm shield R 1½" [(BSPT), EN 10226], B c/w integral 100 mm shield G 1½" [(BSPP), EN ISO 228-1], C c/w integral 100 mm shield 1½" NPT [(Taper), ANSI/ASME B1.20.1], D c/w integral 250 mm shield R 1½" [(BSPT), EN 10226], E c/w integral 250 mm shield G 1½" [(BSPP), EN ISO 228-1], F c/w integral 250 mm shield Approvals General Purpose, CE, R&TTE, RCM A General Purpose, CSA, FM, Industry Canada, FCC B Intrinsically Safe, CSA Class I, II, Div. 1, Groups A, C B, C, D, E, F, G, Industry Canada Intrinsically Safe, FM Class I, II, Div. 1, Groups A, D B, C, D, E, F, G, FCC Intrinsically Safe, IECEx/ATEX II 1G Ex ia IIC T, E INMETRO Ex ia IIC T, CE, R&TTE, RCM; GOST-R Non incendive, FM Class I, Div. 2, Groups A, B, C, F D, FCC 1) Increased Safety, ATEX II 1/2G Ex e mb ia IIC T G Ga/Gb, CE, R&TTE, RCM; GOST-R 2)3) Flame Proof, ATEX II 1/2G Ex d mb ia IIC T Ga/ H Gb, CE, R&TTE, RCM; GOST-R 3) Explosion Proof, CSA/FM Class I, II, III, Groups A, J B, C, D, E, F, G, Industry Canada, FCC 1)3) Communication/Output PROFIBUS PA ma, HART, start-up at < 3.6 ma 3 1) Available with enclosure option 2 only 2) Available with enclosure option 3 only 3) Available with communication option 3 only Order code Further designs Please add "-Z" to and specify Order code(s). Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Y15 Measuring-point number/identification (max. 27 characters); specify in plain text Manufacturer's test certificate: M to DIN 55350, C11 Part 18 and to ISO 9000 Namur NE3 compliant, device preset to failsafe N07 <3.6mA 1) Operating Instructions for HART/mA device English A5E German A5E Note: The Operating Instructions should be ordered as a separate line item on the order. Multi-language Quick Start manual A5E This device is shipped with the Siemens Milltronics manual DVD containing the ATEX Quick Start and Operating Instructions library. Operating Instructions for PROFIBUS PA device English A5E German A5E Note: The Operating Instructions should be ordered as a separate line item on the order. Multi-language Quick Start manual A5E This device is shipped with the Siemens Milltronics manual DVD containing the ATEX Quick Start and Operating Instructions library. Accessories Handheld programmer, Intrinsically safe, EEx ia 7ML1930-1BK HART modem/usb 7MF997-1DB (for use with a PC and SIMATIC PDM) One metallic cable gland M20x1.5, 7ML1930-1AP rated C ( F), HART 2) One metallic cable gland M20x1.5, 7ML1930-1AQ rated C ( F), PROFIBUS PA 2) One general purpose polymeric cable gland 7ML1930-1AM M20x1.5, rated C ( F) SITRANS RD100, loop powered display - 7ML see Chapter 7 SITRANS RD200, universal input display with 7ML Modbus conversion - see Chapter 7 SITRANS RD300, dual line display with totalizer 7ML and linearization curve and Modbus conversion - see Chapter 7 SITRANS RD500 web, universal remote monitoring 7ML solution for instrumentation - see Chapter 7 For applicable back up point level switch - see point level measurement section 1) Available with communication option 3 only 2) Product shipped with plastic cable gland, rated to -20 C. If -0 C rating required, then metallic cable gland is recommended. /200 Siemens FI 01 June 2015

201 Continuous level measurement - Radar transmitters SITRANS LR200 SITRANS LR200, Flange Adapter/PTFE Rod Antenna Version 2-wire, 6 GHz pulse radar level transmitter for continuous monitoring of liquids and slurries in process vessels including high temperature and pressure, to a range of 20 m (66 ft). Click on the for the online configuration in the PIA Life Cycle Portal. Antenna material (uses antenna adapter) PTFE, uses antenna adapter and additional process connection below Process connection (refer to Pressure/ Temperature curves, page /208) Flanges (316L stainless steel) DN 50 PN 16, Type A, flat faced DN 80 PN 16, Type A, flat faced DN 100 PN 16, Type A, flat faced DN 150 PN 16, Type A, flat faced 7ML AA BA CA DA 2" ASME 150 lb, flat faced FB 3" ASME 150 lb, flat faced GB " ASME 150 lb, flat faced HB 6" ASME 150 lb, flat faced JB DN 50 PN 0, flat faced AC DN 80 PN 0, flat faced BC DN 100 PN 0, flat faced CC DN 150 PN 0, flat faced DC 2" ASME 300 lb, flat faced, available with FD Pressure rating option 1 only due to flange hole spacing 3" ASME 300 lb, flat faced GD " ASME 300 lb, flat faced HD 6" ASME 300 lb, flat faced JD JIS DN 50 10K AE JIS DN 80 10K BE JIS DN K CE JIS DN K DE (Note: Flange bolting patterns and facings dimensionally correspond to the applicable ASME B16.5, or EN , or JIS B 2220 standard.) Threaded connection (316L stainless steel) 1½" NPT [(Taper), ANSI/ASME B1.20.1] LA 2" NPT [(Taper), ANSI/ASME B1.20.1] MA R 1½" [(BSPT), EN 10226] LC R 2" [(BSPT), EN 10226] MC G 1½" [(BSPP), EN ISO 228-1] LE G 2" [(BSPP), EN ISO 228-1] ME Antenna extensions or Inactive shield length No antenna extension 0 50 mm (2 inch) extension, PTFE mm ( inch) extension, PTFE mm ( inch) extension, 316L stainless steel shield 1) mm (6 inch) extension, 316L stainless steel shield 1) 200 mm (8 inch) extension, 316L stainless steel shield 1) mm (10 inch) extension, 316L stainless steel shield 1) 6 Process seal/gasket Integral Gasket, 0 for flat faced flange process connections only, not for Antenna extension options FKM O-ring, 1 not available for combination of flat faced flanges with Antenna extension options 0, 1 or 2 1 SITRANS LR200, Flange Adapter/PTFE Rod 7ML523- Antenna Version wire, 6 GHz pulse radar level transmitter for continuous monitoring of liquids and slurries in process vessels including high temperature and pressure, to a range of 20 m (66 ft). Enclosure/Cable inlet Aluminum, Epoxy painted 2 x ½" NPT 2 2 x M20x1.5 3 Communication/Output PROFIBUS PA B ma, HART, start-up at < 3.6 ma C Approvals General Purpose, CE, R&TTE, RCM A General Purpose, CSA, FM, Industry Canada, FCC B Intrinsically Safe, CSA Class I, II, Div. 1, C Groups A, B, C, D, E, F, G, Industry Canada Intrinsically Safe, FM Class I, II, Div. 1, Groups A, D B, C, D, E, F, G, FCC Intrinsically Safe, IECEx/ATEX II 1G Ex ia IIC T, E INMETRO Ex ia IIC T, CE, R&TTE, RCM; GOST-R Non incendive, FM Class I, Div. 2, Groups A, B, C, D, F FCC 2) Increased Safety, ATEX II 1/2G Ex e mb ia IIC T G Ga/Gb, CE, R&TTE, RCM; GOST-R 3)) Flame Proof, ATEX II 1/2G Ex d mb ia IIC T Ga/ H Gb, CE, R&TTE, RCM; GOST-R ) Explosion Proof, CSA/FM Class I, II, III, Groups A, J B, C, D, E, F, G, Industry Canada, FCC 2)) Pressure rating Rating per Pressure/Temperature curves in manual bar g (7.25 psi g) maximum 1 1) Available with process connection options BA, CA, DA, GB, HB, JB, BC, CC, DC, GD, HD, JD, BE, CE, DE, MA, MC, ME only 2) Available with enclosure option 2 only 3) Available with enclosure option 3 only ) Available with communication option C only Siemens FI 01 June 2015 /201

202 Continuous level measurement - Radar transmitters SITRANS LR200 Further designs Please add "-Z" to and specify Order code(s). Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Measuring-point number/identification (max. 27 characters); specify in plain text Manufacturer's test certificate: M to DIN 55350, Part 18 and to ISO 9000 Inspection Certificate Type 3.1 per EN 1020 Namur NE3 compliant, device preset to failsafe <3.6mA 3) Operating Instructions for HART/mA device English German Note: The Operating Instructions should be ordered as a separate line item on the order. Multi-language Quick Start manual This device is shipped with the Siemens Milltronics manual DVD containing the ATEX Quick Start and Operating Instructions library. Operating Instructions for PROFIBUS PA device English German Note: The Operating Instructions should be ordered as a separate line item on the order. Multi-language Quick Start manual This device is shipped with the Siemens Milltronics manual DVD containing the ATEX Quick Start and Operating Instructions library. Accessories Handheld programmer, Intrinsically safe, EEx ia Antenna, rod, PTFE Antenna extension, 50 mm (2 inch), PTFE Antenna extension, 100 mm ( inch), PTFE HART modem / USB (for use with PC and SIMATIC PDM) Metallic cable gland M20 x 1.5, rated -0 C (-0 F) C (176 F), HART (two are required) Metallic cable gland M20 x 1.5, rated -0 C (-0 F) C (176 F), PROFIBUS PA (two required) One General Purpose polymeric cable gland M20 x 1.5, rating for -20 C (- F) C (176 F) SITRANS RD100, loop powered display - see Chapter 7 SITRANS RD200, universal input display with Modbus conversion - see Chapter 7 SITRANS RD300, dual line display with totalizer and linearization curve and Modbus conversion - see Chapter 7 SITRANS RD500 web, universal remote monitoring solution for instrumentation - see Chapter 7 For applicable back up point level switch - see point level measurement section Order code Y15 C11 C12 N07 A5E A5E A5E A5E A5E A5E ML1930-1BK 7ML1830-1HC 7ML1830-1CH 7ML1830-1CG 7MF997-1DB 7ML1930-1AP 7ML1930-1AQ 7ML1930-1AM 7ML ML ML ML /202 Siemens FI 01 June 2015

203 Continuous level measurement - Radar transmitters SITRANS LR200 SITRANS LR200, Flange adapter/horn Antenna version 2-wire, 6 GHz pulse radar level transmitter for continuous monitoring of liquids and slurries in process vessels including high temperature and pressure, to a range of 20 m (66 ft). Click on the for the online configuration in the PIA Life Cycle Portal. 2 Antenna material (uses antenna adapter) 316L stainless steel with PTFE cone emitter 0 316L stainless steel with PTFE cone emitter and purge connection with 1/8" NPT inlet 1) 1 Sliding waveguide system with mm (0 inch) waveguide 1)2) Process connection (refer to Pressure/ Temperature curves, page /209) Flanges (316L stainless steel) DN 50 PN 16 EN Type A flat faced 1) AA DN 80 PN 16 EN Type A flat faced BA DN 100 PN 16 EN Type A flat faced CA DN 150 PN 16 EN Type A flat faced DA DN 200 PN 16 EN Type A flat faced EA DN 80 PN 10/16 DIN EN Type B1 raised face 3) BF DN 100 PN 10/16 DIN EN Type B1 raised face 3) CF DN 150 PN 10/16 DIN EN Type B1 raised face 3) DF DN 200 PN 16 DIN EN Type B1 raised face 3) EF 2" ASME 150 lb, flat faced 1) FB 3" ASME 150 lb, flat faced GB " ASME 150 lb, flat faced HB 6" ASME 150 lb, flat faced JB 8" ASME 150 lb, flat faced KB DN 50 PN 0, flat faced 3) AC DN 80 PN 0, flat faced 3) BC DN 100 PN 0, flat faced 3) CC DN 200 PN 0, flat faced 3) EC DN 80 PN 25/0 DIN EN Type B1 raised face 3) CG DN 100 PN 25/0 DIN EN Type B1 raised DG face 3) DN 150 PN 25/0 DIN EN Type B1 raised EG face 3) 2" ASME 300 lb, flat faced 1)3) FD 3" ASME 300 lb, flat faced 3) GD " ASME 300 lb, flat faced 3) HD JIS DN 50 10K 1) AE JIS DN 80 10K BE JIS DN K CE JIS DN K JIS DN K (Note: Flange bolting patterns and facings dimensionally correspond to the applicable ASME B16.5, or EN , or JIS B 2220 standard.) 7ML DE EE Communication/Output PROFIBUS PA ma, HART, start-up at < 3.6 ma 2 SITRANS LR200, 7ML525- Flange adapter/horn Antenna version wire, 6 GHz pulse radar level transmitter for continuous monitoring of liquids and slurries in process vessels including high temperature and pressure, to a range of 20 m (66 ft). Process seal/gasket FKM ( C) 0 Nitrile ( C), 1 sliding waveguide systems only FFKM ( C) 2 Enclosure/Cable inlet Aluminum, Epoxy painted 2 x ½" NPT 2 2 x M20x1.5 3 Horn size/waveguide options 80 mm (3 inch) horn ) B 100 mm ( inch) horn ) C 150 mm (6 inch) horn D 200 mm (8 inch) horn E 100 mm ( inch) horn with 100 mm ( inch) F waveguide extension ) 100 mm ( inch) horn with 150 mm (6 inch) G waveguide extension ) 100 mm ( inch) horn with 200 mm (8 inch) H wave-guide extension ) 100 mm ( inch) horn with 250 mm (10 inch) J waveguide extension ) 150 mm (6 inch) horn with 100 mm ( inch) K waveguide extension 150 mm (6 inch) horn with 150 mm (6 inch) L waveguide extension 150 mm (6 inch) horn with 200 mm (8 inch) M waveguide extension 150 mm (6 inch) horn with 250 mm (10 inch) N waveguide extension 200 mm (8 inch) horn with 100 mm ( inch) P waveguide extension 200 mm (8 inch) horn with 150 mm (6 inch) Q waveguide extension 200 mm (8 inch) horn with 200 mm (8 inch) R waveguide extension 200 mm (8 inch) horn with 250 mm (10 inch) S waveguide extension (Add Order code Y01 and plain text: "waveguide length... mm") Siemens FI 01 June 2015 /203

204 Continuous level measurement - Radar transmitters SITRANS LR200 SITRANS LR200, 7ML525- Flange adapter/horn Antenna version wire, 6 GHz pulse radar level transmitter for continuous monitoring of liquids and slurries in process vessels including high temperature and pressure, to a range of 20 m (66 ft). Approvals General Purpose, CE, R&TTE, RCM A General Purpose, CSA, FM, Industry Canada, FCC B Intrinsically Safe, CSA Class I, II, Div. 1, Groups A, C B, C, D, E, F, G, Industry Canada Intrinsically Safe, FM Class I, II, Div. 1, Groups A, B, D C, D, E, F, G, FCC Intrinsically Safe, IECEx/ATEX II 1G Ex ia IIC T, E INMETRO Ex ia IIC T, CE, R&TTE, RCM; GOST-R Non incendive, FM Class I, Div. 2, Groups A, B, C, D, F FCC 5) Increased Safety, ATEX II 1/2G Ex e mb ia IIC T G Ga/Gb, CE, R&TTE, RCM; GOST-R 6)7) Flame Proof, ATEX II 1/2G Ex d mb ia IIC T Ga/Gb, H CE, R&TTE, RCM; GOST-R 7) Explosion Proof, CSA/FM Class I, II, III, Groups A, J B, C, D, E, F, G, Industry Canada, FCC 5)7) Pressure rating Rating per Pressure/Temperature curves in manual bar g (7.25 psi g) maximum 1 1) Available with pressure rating option 1 only 2) Maximum Process Temperature 60 C (10 F) 3) Available with Antenna Material option 0 and 1 only ) For stillpipe applications only 5) Available with enclosure option 2 only 6) Available with enclosure option 3 only 7) Available with communication option 2 only Order code Further designs Please add "-Z" to and specify Order code(s). Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Y15 Measuring-point number/identification (max. 27 characters); specify in plain text Manufacturer's test certificate: M to DIN 55350, C11 Part 18 and to ISO 9000 Inspection Certificate Type 3.1 per EN 1020 C12 Namur NE3 compliant, device preset to failsafe N07 <3.6mA 1) Operating Instructions for HART/mA device English A5E German A5E Note: The Operating Instructions should be ordered as a separate line item on the order. Multi-language Quick Start manual A5E This device is shipped with the Siemens Milltronics manual DVD containing the ATEX Quick Start and Operating Instructions library. Operating Instructions for PROFIBUS PA device English A5E German A5E Note: The Operating Instructions should be ordered as a separate line item on the order. Multi-language Quick Start manual A5E This device is shipped with the Siemens Milltronics manual DVD containing the ATEX Quick Start and Operating Instructions library. Accessories Handheld programmer, Intrinsically safe, EEx ia 7ML1930-1BK HART modem/usb 7MF997-1DB (for use with a PC and SIMATIC PDM) One metallic cable gland M20x1.5, 7ML1930-1AP rated C ( F), HART 2) One metallic cable gland M20x1.5, 7ML1930-1AQ rated C ( F), PROFIBUS PA 3) One general purpose polymeric cable gland 7ML1930-1AM M20x1.5, rated C ( F) SITRANS RD100, loop powered display - 7ML see Chapter 7 SITRANS RD200, universal input display with 7ML Modbus conversion - see Chapter 7 SITRANS RD300, dual line display with totalizer 7ML and linearization curve and Modbus conversion - see Chapter 7 SITRANS RD500 web, universal remote monitoring 7ML solution for instrumentation - see Chapter 7 For applicable back up point level switch - see point level measurement section 1) Available with communication option 2 only 2) Product shipped with plastic cable gland, rated to -20 C. If -0 C rating required, then metallic cable gland is recommended. 3) Available with enclosure option 2 only /20 Siemens FI 01 June 2015

205 Continuous level measurement - Radar transmitters SITRANS LR200 Dimensional drawings SITRANS LR200 with polypropylene shielded rod antenna PTFE rod antenna, threaded Threaded connection PTFE rod, external shield ½ NPT cable entry (or alternatively M20 x 1.5 cable gland) Threaded cover Nameplate Nameplate 158 (6.1) Std. 296 (11.7) min. Option: 6 (17.6) max. Std. 575 (22.6) min. Option: 725 (28.5) max. 15 (6) Enclosure/ electronics Locking ring Reference point Mounting thread Polypropylene rod antenna 185 (7.3) Reference point AISI 316, 2 NPT, R 2 (BSPT) or G 2 (BSPP) PTFE antenna Shield length (internal): Standard: 100 () Optional: 250 (10) 12 (16.3) 187 (7.) 17 (0.67) Reference point AISI 316, 2 NPT, R 2 (BSPT) or G 2 (BSPP) Antenna shield (inactive length) AISI 316 Active antenna (PTFE) Shield Length (S.L.): min. 100 () (customer specified) Overall Length (L): 37 (1.7) plus shielded length S.L. 187 (7.) 18 (0.7) L Horn antenna with flat faced flange Enclosure/electronics Sliding waveguide Reference point 187 (7.) Nameplate Locking ring Flange Nameplate Reference point 187 (7.) 0 (1.6) Ø80 (3) Horn 100 () 150 (6) 200 (8) 131 (5.16) (8.89) (12.79) Sliding flange 93 (36.8) (0.8) 100 () 150 (6) 200 (8) 111 (.0) 206 (8.11) 305 (12.01) Fully inserted length = 93 mm + horn height SITRANS LR200, dimensions in mm (inch) Siemens FI 01 June 2015 /205

206 Continuous level measurement - Radar transmitters SITRANS LR200 Schematics Connect the wires to the terminals as shown: the polarity is identified on the terminal block. Hand programmer Gland Shield for HART and PROFIBUS PA intrinsically safe versions only. Part number: 7ML1930-1BK Notes: 1. DC terminal shall be supplied from an SELV source in accordance with IEC Annex H. 2. All field wiring must have insulation suitable for rated input voltages. 3. Use shielded twisted pair cable ( AWG) for HART version.. Separate cables and conduit may be required to conform to standard instrumentation wiring practices or electrical codes. SITRANS LR200 connections /206 Siemens FI 01 June 2015

207 Continuous level measurement - Radar transmitters SITRANS LR200 Antennas Integration Horn with waveguide extension. Used for high temperature isolation, long standpipes, and clearing tank obstructions. Flat faced flange connection with PTFE rod antenna. Shielded rod antenna with a stainless steel shield eliminates standpipe interference. Various lengths available. Sliding waveguide antenna, typically for digester applications that include an isolation valve between the instrument and the vessel. SITRANS LR200 with flange adapter for connection to optional antennas. Antenna configurations for SITRANS LR200 Technical specifications Antenna Types Flat Faced Flange with Rod Shielded Rod Horn (", 6", 8" sizes available) Connection type Flat faced flange nominal pipe sizes 50, 80, 100, 150 mm (2, 3,, 6 inch) 1) Maximum pressure 0.5 bar g at 60 C (7.25 psi g at 10 F) 2) Not including extensions, includes SITRANS LR200 and smallest process connection Threaded 2" NPT, R 2" (BSPT), G 2" (BSPP) or flat faced flange nominal pipe sizes 80, 100 mm (3, inch) Flat faced flange nominal pipe sizes 50, 80, 100, 150 mm (2, 3,, 6 inch) Wetted parts PTFE PTFE, 316L stainless steel, FKM o-ring 316L stainless steel, PTFE, FKM o-ring Extensions 50 or 100 mm (2 or inch) PTFE or UHMW-PE 100, 150, 200 or 250 mm (, 6, 8 or 10 inch) standard shield length Use waveguide for extensions to 6 m (20 ft) long Dielectric constant > 3 > 3 > 3 Insertion length (max.) 1 cm (16.3 inch) Variable Variable with extension Purging option (liquid or gas) No No Yes Sliding waveguide option for Yes No Yes digesters 1) Weight 2) 6.5 kg (1.3 lb) 5.0 kg (11 lb) 7.5 kg (16.5 lb) Siemens FI 01 June 2015 /207

208 Continuous level measurement - Radar transmitters SITRANS LR200 Antennas Characteristic curves Maximum flange and process temperatures versus allowable ambient temperature Ambient temperature ( C) Polypropylene rod 130 C PTFE rod/ horn antenna Process flange surface temperature ( C) 67 C SITRANS LR200 Ambient/Process Flange Surface Temperature Curve /208 Siemens FI 01 June 2015

209 Continuous level measurement - Radar transmitters SITRANS LR200 Antennas 16.0 PTFE rod antenna with integral gasket 150# and PN 16 sizes flange series 2252, 316 stainless steel, flat face Pressure (bar, gauge) (A) (B) (C) (A) mm/2 inch nom. 2.0 (B) mm/3 inch nom Temperature ( C) (C) mm/ inch nom. Pressure (bar, gauge) Horn antenna and/or wave guide with PTFE ermitter 150# and PN 16 sizes flange series 2252, 316 stainless steel, flat face (E) (F) (G) (D) (D) mm/3 inch nom. (E) mm/ inch nom. 2.0 (F) mm/6 inch nom Temperature ( C) (G) mm/8 inch nom. 0.0 Threaded process 1.5" & 2" NPT, BSP, & G 35.0 Pressure (bar, gauge) (H) (H) 1.5" and 2", thread connection Temperature ( C) SITRANS LR200 Process Pressure/Temperature derating curves Siemens FI 01 June 2015 /209

210 Continuous level measurement - Radar transmitters SITRANS LR200 Specials Selection and ordering data SITRANS LR200 Specials SITRANS LR200 Specials SITRANS LR200 PROFIBUS PA Aluminum Enclosure Kit with electronics and covers (7ML522, 7ML523, 7ML52, 7ML525), calibrated for use with standard rod antenna SITRANS LR200 aluminum enclosure with board stack, LUI display, 5.8 GHz, NPT cable inlet, approval option A, with HART communication start-up at < 3.6 ma, no process connection. 5) SITRANS LR200 aluminum enclosure with board stack, LUI display, 6.3 GHz, NPT cable inlet, approval option B, with HART communication start-up at < 3.6 ma, no process connection. 5) SITRANS LR200 aluminum enclosure with board stack, LUI display, 5.8 GHz, NPT cable inlet, approval option C, with HART communication start-up at < 3.6 ma, no process connection. 5) SITRANS LR200 aluminum enclosure with board stack, LUI display, 6.3 GHz, NPT cable inlet, approval option E, with HART communication start-up at < 3.6 ma, no process connection. 5) SITRANS LR200 Horn Antenna Kits with mounting screws (no emitter supplied) A5E SITRANS LR200 aluminum enclosure with board stack, LUI display, 5.8 GHz, M20 cable inlet, approval option E, with PROFIBUS PA communication, no process connection. 5) SITRANS LR200 aluminum enclosure with board stack, LUI display, 5.8 GHz, M20 cable inlet, approval option A, with PROFIBUS PA communication, no process connection. 5) SITRANS LR200 aluminum enclosure with board stack, LUI display, 6.3 GHz, M20 cable inlet, approval option C, with PROFIBUS PA communication, no process connection. 5) SITRANS LR200 aluminum enclosure with board stack, LUI display, 6.3 GHz, NPT cable inlet, approval option C, with PROFIBUS PA communication, no process connection. 5) SITRANS LR200 aluminum enclosure with board stack, LUI display, 5.8 GHz, NPT cable inlet, approval option E, with PROFIBUS PA communication, no process connection. 5) SITRANS LR200 HART aluminum enclosure kit with electronics and covers (7ML522, 7ML523, 7ML52, 7ML525), calibrated for use with standard rod antenna A5E A5E01830 A5E A5E A5E A5E A5E A5E mm (3 inch) horn antenna kit PBD:25500K02A 100 mm ( inch) horn antenna kit PBD:25500K03A 150 mm (6 inch) horn antenna kit PBD:25500K05A 200 mm (8 inch) horn antenna kit PBD:25500K07A SITRANS LR200 Extension Kits for Horn Antenna with mounting screws 100 mm ( inch) extension kit for horn antenna PBD:25501K0100A 150 mm (6 inch) extension kit for horn antenna PBD:25501K0150A 200 mm (8 inch) extension kit for horn antenna PBD:25501K0200A 250 mm (10 inch) extension kit for horn antenna PBD:25501K0250A 500 mm (20 inch) extension kit for horn antenna PBD:25501K0500A mm (0 inch) extension kit for PBD:25501K1000A horn antenna SITRANS LR200 Flanged Rod Antenna Kit with 316L stainless steel flat faced flanges SITRANS LR200 aluminum enclosure with board stack, LUI display, 5.8 GHz, M20 cable inlet, approval option A, with HART communication start-up at < 3.6 ma, no process connection. 5) SITRANS LR200 aluminum enclosure with board stack, LUI display, 5.8 GHz, M20 cable inlet, approval option E, with HART communication start-up at < 3.6 ma, no process connection. 5) SITRANS LR200 aluminum enclosure with board stack, LUI display, 5.8 GHz, M20 cable inlet, approval option G, with HART communication start-up at < 3.6 ma, no process connection. 5) SITRANS LR200 aluminum enclosure with board stack, LUI display, 5.8 GHz, M20 cable inlet, approval option H, with HART communication start-up at < 3.6 ma, no process connection. 5) A5E A5E A5E A5E Flanged PTFE rod antenna kit, 2" ASME, 150 lb. See drawing on 1)) Flanged PTFE rod antenna kit, DN 50 PN 16. See drawing on 1)) Flanged PTFE rod antenna kit, JIS 10K DN 50. See drawing on 1)) PBD: 51003K020AAAA PBD: 51003K050AJAA PBD: 51003K050AOAA /210 Siemens FI 01 June 2015

211 Continuous level measurement - Radar transmitters SITRANS LR200 Specials SITRANS LR200 Specials SITRANS LR200 Specials SITRANS LR200 PTFE Rod Antenna Kit with 316L stainless steel 1½"pipe thread process connection SITRANS LR200 PTFE Rod Antenna Kit (100 mm shield) with 316L stainless steel 2" pipe thread process connection PTFE rod antenna kit, 1½" NPT 316L stainless steel process connection, FKM O-ring; See drawing 5100 on ) PTFE rod antenna kit, R 1½" (BSPT), EN L stainless steel process connection, FKM O-ring; see drawing 5100 on ) PTFE rod antenna kit, 1½" G 316L stainless steel process connection, FKM O-ring; see drawing 5100 on ) SITRANS LR200 PTFE Rod Antenna Kit with 316L stainless steel 2" pipe thread process connection PBD: 5100K1AAA PBD: 5100K2AAA PBD: 5100K3AAA PTFE rod antenna shielded kit, 2" NPT 316L stainless steel process connection, FKM O-ring, 100 mm 316L stainless steel shield. See drawing on 3)) PTFE rod antenna shielded kit, R 2" (BSPT), EN L stainless steel process connection, FKM O-ring, 100 mm 316L stainless steel shield. See drawing on 3)) PTFE rod antenna shielded kit, 2" G 316L stainless steel process connection, FKM O-ring, 100 mm 316L stainless steel shield. See drawing on 3)) SITRANS LR200 Horn Antenna Kit with 316L stainless steel flat faced flange, with PTFE emitter (without waveguide) PBD: 51002K0100AAA PBD: 51002K0100BAA PBD: 51002K0100CAA PTFE rod antenna kit, 2" NPT 316L stainless steel process connection, FKM O-ring; see drawing on ) PBD: 51005K1AAA Horn antenna kit, 2" ASME 316L stainless steel flange 3" horn, PTFE emitter 1)) PBD: 51006K020AAAA PTFE rod antenna kit, R 2" (BSPT), EN L stainless steel process connection, FKM O-ring; see drawing on ) PTFE rod antenna kit, 2" G 316L stainless steel process connection, FKM O-ring; see drawing on ) PBD: 51005K2AAA PBD: 51005K3AAA Horn antenna kit, 2" ASME 316L stainless steel flange " horn, PTFE emitter 1)2) Horn antenna kit, 2" ASME 316L stainless steel flange 6" horn, PTFE emitter 1)2) Horn antenna kit, 2" ASME 316L stainless steel flange 8" horn, PTFE emitter 1)2) Horn antenna kit, DN 50 PN L stainless steel flange 80 mm horn, PTFE emitter 1)2) PBD: 51006K020AABA PBD: 51006K020AACA PBD: 51006K020AADA PBD: 51006K050AJAA Horn antenna kit, DN 50 PN L stainless steel flange 100 mm horn, PTFE emitter 1)2) PBD: 51006K050AJBA Horn antenna kit, DN 50 PN L stainless steel flange 150 mm horn, PTFE emitter 1)2) PBD: 51006K050AJCA Horn antenna kit, DN 50 PN L stainless steel flange 200 mm horn, PTFE emitter 1)2) PBD: 51006K050AJDA Siemens FI 01 June 2015 /211

212 Continuous level measurement - Radar transmitters SITRANS LR200 Specials SITRANS LR200 Specials SITRANS LR200 Specials SITRANS LR200 PTFE flanged rod antenna kit with 316L stainless steel shield and 316L stainless steel flat faced flange PTFE paste Kit, PTFE paste, Tube, 250 ml Cable gland PBD: One polymeric cable gland M20x1.5, rated C ( F) for General Purpose and ATEX EEx e 7ML1930-1AN PTFE shielded rod antenna kit, flanged, 3" ASME 150 lb 316L stainless steel flange, 100 mm 316L stainless steel shield. 1)) PTFE shielded rod antenna kit, flanged, DN 80 PN L stainless steel flange, 100 mm 316L stainless steel shield. 1)) PTFE shielded rod antenna kit, flanged, 3" ASME 150 lb 316L stainless steel flange, 150 mm 316L stainless steel shield. 1)) PTFE shielded rod antenna kit, flanged, DN 80 PN L stainless steel flange, 150 mm 316L stainless steel shield. 1)) PTFE shielded rod antenna kit, flanged, 3" ASME 150 lb 316L stainless steel flange, 200 mm 316L stainless steel shield. 1)) PBD: 5101K0100AAA PBD: 5101K0100EJA PBD: 5101K0150AAA PBD: 5101K0150EJA PBD: 5101K0200AAA One metallic cable gland M20x1.5, rated C ( F), HART One metallic cable gland M20x1.5, rated C ( F), PROFIBUS PA 7ML1930-1AP 7ML1930-1AQ Please contact ceg.smpi@siemens.com for special requests. 1) Available in flange sizes including ASME, DIN and JIS: please contact ceg.smpi@siemens.com. 2) Available with no pressure rating 3) Available in other shield lengths: please contact ceg.smpi@siemens.com. ) Available with Pressure rating; serial number of original unit required with completed Application Questionnaire found on page /193. PTFE shielded rod antenna kit, flanged, DN 80 PN L stainless steel flange, 200 mm 316L stainless steel shield. 1)) PBD: 5101K0200EJA PTFE shielded rod antenna kit, flanged, 3" ASME 150 lb 316L stainless steel flange, 250 mm 316L stainless steel shield. 1)) PBD: 5101K0250AAA PTFE shielded rod antenna kit, flanged, DN 80 PN L stainless steel flange, 250 mm 316L stainless steel shield. 1)) PBD: 5101K0250EJA /212 Siemens FI 01 June 2015

213 Continuous level measurement - Radar transmitters SITRANS LR250 Horn Antenna Overview Configuration Installation SITRANS LR250 is a 2-wire, 25 GHz pulse radar level transmitter for continuous monitoring of liquids and slurries in storage and process vessels including high temperature and pressure, to a range of 20 m (66 ft). Note: Beam angle is the width of the cone where the energy density is half of the peak energy density. The peak energy density is directly in front of and in line with the horn antenna. There is a signal transmitted outside of the beam angle; therefore false targets may be detected. Use largest possible antenna. Mounting unit on bypass 19 beam width: 1.5 horn = horn = horn = 10.0 horn = 8 Mounting unit on stilling well Benefits Graphical local user interface (LUI) makes operation simple with plug-and-play setup using the intuitive Quick Start Wizard LUI displays echo profiles for diagnostic support 25 GHz high frequency allows for small antennas for easy mounting in nozzles Insensitive to mounting location and obstructions, and less sensitive to nozzle interference Short blanking distance for improved minimum measuring range to 50 mm (2 inch) from the end of the antenna Communication using HART, PROFIBUS PA, or FOUNDATION Fieldbus Process Intelligence signal processing for improved measurement reliability and Auto False-Echo Suppression of fixed obstructions Programming using infrared Intrinsically Safe handheld programmer or over a network using SIMATIC PDM, Emerson AMS, or Field Device Tools, such as PACTware or Fieldcare via SITRANS DTM Functional Safety (SIL 2). Device suitable for use in accordance with IEC and IEC mm (0.118 inch) accuracy in accordance with IEC Orient front or back of device toward vent. Mounting unit on vessel Orient front or back of device toward stillpipe slots. Use largest horn size possible in pipe. Mounting on a nozzle Application SITRANS LR250 includes a graphical local user interface (LUI) that improves setup and operation by including an intuitive Quick Start Wizard, and echo profile displays for diagnostic support. Startup is easy using the Quick Start wizard with a few parameters required for basic operation. The 25 GHz frequency creates a narrow, focused beam allowing for smaller horn antenna options and decreasing sensitivity to obstructions. SITRANS LR250 s unique design allows safe and simple programming using the Intrinsically Safe handheld programmer without saving to open the instrument s lid. SITRANS LR250 measures superbly on low dielectric media, and in small vessels, as well as tall and narrow vessels. Key Applications: liquid bulk storage tanks, process vessels, vaporous liquids, high temperatures, low dielectric media and applications with functional safety requirements SITRANS LR250 installation, dimensions in mm (inch) Min. 10 (0.) Siemens FI 01 June 2015 /213

214 Continuous level measurement - Radar transmitters SITRANS LR250 Horn Antenna Technical specifications Mode of operation Measuring principle Radar level measurement Frequency K-band (25.0 GHz) Minimum measuring range 50 mm (2 inch) from end of antenna Maximum measuring range 20 m (65 ft), antenna dependent Output HART: Version 5.1 Analog output ma Accuracy ± 0.02 ma Fail-safe Programmable as high low or hold (loss of echo) NE 3 programmable PROFIBUS PA: Profile 3.01 Function blocks 2 Analog Input (AI) FOUNDATION Fieldbus H1 Functionality Basic or LAS Version ITK Function blocks 2 Analog Input (AI) Performance (according to reference conditions IEC ) Maximum measured error 3 mm (0.118 inch) Influence of ambient temperature < %/K Rated operating conditions Installation conditions Location Indoor/outdoor Ambient conditions (enclosure) Ambient temperature C ( F) Installation category I Pollution degree Medium conditions Dielectric constant ε r > 1.6, antenna and application dependent Process temperature C ( F) (at process connection with FKM O-ring) C ( F) (at process connection with FFKM O-ring) Process pressure Up to 0 bar g (580 psi g), process connection and temperature dependent. See Pressure/Temperature curves for more information Design Enclosure Material Aluminum, polyester powder-coated Cable inlet 2 x M20x1.5 or 2 x ½" NPT Degree of protection Type X/NEMA X, Type 6/NEMA 6, IP67, IP68 Weight < 3 kg (6.6 lb) 3.75 mm (1½ inch) threaded connection with 1½" horn antenna Display (local) Graphic local user interface including quick start wizard and echo profile display Antenna Material Dimensions (nominal horn sizes) 316L stainless steel [optional alloy N06022/2.602 (Hastelloy C-22 or equivalent)] Standard 1.5 inch (0 mm), 2 inch (8 mm), 3 inch (75 mm), inch (95 mm) horn and optional 100 mm ( inch) horn extension Process connections Process connection Flange connection 1½", 2" or 3" NPT [(Taper), ANSI/ASME B1.20.1] R 1½", 2" or 3" [(BSPT), EN 10226] G 1½", 2" or 3" [(BSPP), EN ISO 228-1] 2", 3", " (ANSI 150, 300 lb), 50, 80, 100 mm (PN 16, 0, JIS 10K) Power supply ma/hart Nominal 2 V DC (max. 30 V DC) with max. 550 Ω PROFIBUS PA 15 ma Per IEC FOUNDATION Fieldbus 20.0 ma Per IEC Certificates and approvals General CSA US/C, CE, FM, NE 21, RCM Radio FCC, Industry Canada and Europe ETSI EN , RCM Hazardous Explosion Proof (Brazil) INMETRO Ex d ia mb IIC T Ga/Gb, Ex ia ta IIIC T100 C Da Increased Safety (Brazil) INMETRO Ex e ia mb IIC T Ga/Gb, Ex ia ta IIIC T100 C Da Intrinsically Safe (Brazil) INMETRO Ex ia IIC T Ga, Ex ia ta IIIC T100 C Da Explosion Proof (Canada/USA) CSA/FM Class I, Div. 1, Groups A, B, C, D; Class II, Div. 1, Groups E, F, G; Class III T Intrinsically Safe (Canada/USA) CSA/FM Class I, Div. 1, Groups A, B, C, D; Class II, Div. 1, Groups E, F, G; Class III T Non-incendive (Canada/USA) CSA/FM Class I, Div. 2, Groups A, B, C, D T5 Flame Proof/Increased Safety NEPSI Ex d ia mb IIC T Ga/Gb, (China) Ex e ia mb IIC T Ga/Gb, Ex iad 20 T90 IP67 DIP A20 T A 90 ºC Intrinsically Safe (China) NEPSI Ex ia IIC T Ga, Ex iad 20 T90 IP67 DIP A20 T A 90 ºC Non-sparking (China) NEPSI Ex na IIC T Gc Intrinsically Safe (Europe) ATEX II 1G Ex ia IIC T Ga ATEX II 1D Ex ia IIIC T100 C Da Non-sparking (Europe) ATEX II 3G Ex na IIC T Gc Flame Proof (International/Europe) IECEx/ATEX II 1/2 GD, 1D, 2D, Ex d mb ia IIC T Ga/Gb, Ex ia ta IIC T100 C Da Increased Safety (International/Europe) Intrinsically Safe (International) Explosion Proof (Russia) Increased Safety (Russia) Intrinsically Safe (Russia) Marine Functional Safety IECEx/ATEX II 1/2 GD, 1D, 2D, Ex e mb ia IIC T Ga/Gb, Ex ia ta IIIC T100 C Da IECEx/ATEX II 1 G Ex ia IIC T Ga, IECEX/ATEX II 1D Ex ia ta IIC T100 C Da GOST-R Ex d GOST-R Ex e GOST-R Ex ia Lloyd's Register of Shipping ABS Type Approval Bureau Veritas SIL-2 suitable in accordance with IEC 61508/61511 /21 Siemens FI 01 June 2015

215 Continuous level measurement - Radar transmitters SITRANS LR250 Horn Antenna Programming Intrinsically Safe Siemens handheld Infrared receiver programmer Approvals for handheld programmer IS model: ATEX II 1 GD Ex ia IIC T Ga Ex ia D 20 T135 C T a = C CSA/FM Class I, II, III, Div. 1, Groups A, B, C, D, E, F, G, T6 T a = +50 C IECEx SIR Handheld communicator HART communicator 375/75 PC SIMATIC PDM Emerson AMS SITRANS DTM (for connection into FDT, such as PACTware or Fieldcare) Display (local) Graphic local user interface including quick start wizard and echo profile displays Siemens FI 01 June 2015 /215

216 Continuous level measurement - Radar transmitters SITRANS LR250 Horn Antenna SITRANS LR250 horn antenna 2-wire, 25 GHz pulse radar level transmitter for 7ML continuous monitoring of liquids and slurries in storage and process vessels including high temperature and pressure, to a range of 20 m (66 ft) (antenna dependent). Ideal for small vessels and low dielectric media. Click on the for the online configuration in the PIA Life Cycle Portal. Process Connection and Antenna Material 316L (1.35 or 1.0) stainless steel, PTFE emitter, FKM seal 1) 0 316L (1.35 or 1.0) stainless steel, PTFE emitter, FFKM seal 1) 1 Hastelloy C-22/2.602 (or equivalent), PTFE emitter, 2 FKM seal 2) Hastelloy C-22/2.602 (or equivalent), PTFE emitter, FFKM seal 2) 3 Process Connection Type Threaded connection 316L 1½" NPT (ASME B1.20.1) (tapered thread) 3) AA R 1½" [(BSPT), EN ] (tapered thread) 3) AB G 1½" [(BSPP), EN ISO 228-1] (parallel thread) 3) AC 2" NPT (ASME B1.20.1) (tapered thread) AD R 2" [(BSPT), EN ] (tapered thread) AE G 2" [(BSPP), EN ISO 228-1] (parallel thread) AF 3" NPT (ASME B1.20.1) (tapered thread) AG R 3" [(BSPT), EN ] (tapered thread) AH G 3" [(BSPP), EN ISO 228-1] (parallel thread) AJ Flanged connection 316L 2" Class 150 ASME B16.5 flat faced ) BA 3" Class 150 ASME B16.5 flat faced ) BB " Class 150 ASME B16.5 flat faced ) BC 2" Class 300 ASME B16.5 flat faced ) CA 3" Class 300 ASME B16.5 flat faced ) CB " Class 300 ASME B16.5 flat faced ) CC DN 50 PN 16 EN Type A flat faced ) DA DN 80 PN 16 EN Type A flat faced ) DB DN 100 PN 16 EN Type A flat faced ) DC DN 50 PN 0 EN Type A flat faced ) EA DN 80 PN 0 EN Type A flat faced ) EB DN 100 PN 0 EN Type A flat faced ) EC 50A 10K JIS B 2220 flat faced ) FA 80A 10K JIS B 2220 flat faced ) FB 100A 10K JIS B 2220 flat faced ) FC DN 50 PN 16 DIN EN Type B1 raised face GA DN 80 PN 16 DIN EN Type B1 raised face GB DN 100 PN 16 DIN EN Type B1 raised face GC DN 150 PN 16 DIN EN Type B1 raised face GD DN 50 PN 0 DIN EN Type B1 raised face HA DN 80 PN 0 DIN EN Type B1 raised face HB DN 100 PN 0 DIN EN Type B1 raised face HC DN 150 PN 0 DIN EN Type B1 raised face HD SITRANS LR250 horn antenna 2-wire, 25 GHz pulse radar level transmitter for 7ML continuous monitoring of liquids and slurries in storage and process vessels including high temperature and pressure, to a range of 20 m (66 ft) (antenna dependent). Ideal for small vessels and low dielectric media. Flanged connection Hastelloy C 2" Class 150 ASME B16.5 raised faced ) J A 3" Class 150 ASME B16.5 raised faced ) JB " Class 150 ASME B16.5 raised faced ) JC 2" Class 300 ASME B16.5 raised faced ) JD 3" Class 300 ASME B16.5 raised faced ) JE " Class 300 ASME B16.5 raised faced ) JF DN 50 PN 16 EN Type B1 raised faced ) KA DN 80 PN 16 EN Type B1 raised faced ) KB DN 100 PN 16 EN Type B1 raised faced ) KC DN 50 PN 0 EN Type B1 raised faced ) KD DN 80 PN 0 EN Type B1 raised faced ) KE DN 100 PN 0 EN Type B1 raised faced ) KF 50A 10K JIS B 2220 raised faced ) LA 80A 10K JIS B 2220 raised faced ) LB 100A 10K JIS B 2220 raised faced ) LC DN 50 PN 16 EN Type B1 raised face MA DN 80 PN 16 EN Type B1 raised face MB DN 100 PN 16 EN Type B1 raised face MC DN 150 PN 16 EN Type B1 raised face MD DN 50 PN 0 EN Type B1 raised face ME DN 80 PN 0 EN Type B1 raised face MF DN 100 PN 0 EN Type B1 raised face MG DN 150 PN 0 EN Type B1 raised face MH Communication/Output PROFIBUS PA ma, HART, start-up at < 3.6 ma 2 FOUNDATION Fieldbus 3 Enclosure/Cable inlet Aluminum, Epoxy painted 2 x ½" NPT 0 2 x M20x1.5 1 Antenna 1½" horn A 2" horn (fits 2" ASME or DN 50 nozzles) B 3" horn (fits 3" ASME or DN 80 nozzles) C " horn (fits " ASME or DN 100 nozzles) D 1½" horn with 100 mm extension E 2" horn with 100 mm extension F 3" horn with 100 mm extension G " horn with 100 mm extension H Hastelloy C22 (or equivalent) 2" horn (fits 2" ASME or DN 50 nozzles) J 3" horn (fits 3" ASME or DN 80 nozzles) K " horn (fits " ASME or DN 100 nozzles) L 2" horn (fits 2" ASME or DN 50 nozzles) with M 100 mm extension 3" horn (fits 3" ASME or DN 80 nozzles) with N 100 mm extension " horn (fits " ASME or DN 100 nozzles) with 100 mm extension P /216 Siemens FI 01 June 2015

217 Continuous level measurement - Radar transmitters SITRANS LR250 Horn Antenna SITRANS LR250 horn antenna 2-wire, 25 GHz pulse radar level transmitter for 7ML continuous monitoring of liquids and slurries in storage and process vessels including high temperature and pressure, to a range of 20 m (66 ft) (antenna dependent). Ideal for small vessels and low dielectric media. Approvals General Purpose, CE, CSA, FM, FCC, R&TTE, RCM A Intrinsically Safe: CSA/FM Class I, Div. 1, Groups A, B B, C, D, Class II, Div.1, Groups E,F, G, Class III T FCC, Industry Canada Intrinsically Safe: IECEx/ATEX II 1 G Ex ia IIC T Ga, IECEx/ATEX II 1D Ex ia ta IIIC T100 C Da, C INMETRO Ex ia IIC T Ga, Ex ia ta IIIC T100 o C Da, CE, R&TTE, RCM Non-incendive: CSA/FM Class I, Div. 2, Groups A, D B, C, D T5, FCC, Industry Canada Non Sparking: ATEX II 3G Ex na IIC T Gc, CE, E R&TTE, RCM Increased Safety: IECEx/ATEX II 1/2 GD,1D, 2D Ex e mb ia IIC T Ga/Gb, Ex ia ta IIIC T100 C F Da, INMETRO Ex e ia mb IIC T Ga/Gb, Ex ia ta IIIC T100 o C Da, CE, R&TTE, RCM 5) Flameproof: IECEx/ATEX II 1/2 GD 1D, 2D Ex d mb G ia IIC T Ga/Gb, Ex ia ta IIIC T100 C Da, INMETRO Ex d ia mb IIC T Ga/Gb, Ex ia ta IIIC T100 o C Da, CE, R&TTE, RCM 5) Explosion proof: CSA/FM Class I, II and III, Div. 1, Groups A, B, C, D, E, F, G, FCC, Industry Canada 5) H Non Sparking: NEPSI Ex na IIC T Gc K Intrinsically Safe: NEPSI Ex ia IIC T Ga, L Ex iad 20 T90 IP67 DIP A20 T A 90 ºC Flameproof: NEPSI Ex d ia mb IIC T Ga/Gb, M Ex iad 20 T90 IP67 DIP A20 T A 90 ºC 5) Increased Safety: NEPSI Ex e ia mb IIC T Ga/Gb, N Ex iad 20 T90 IP67 DIP A20 T A 90 ºC 5) Pressure rating Rating per Pressure/Temperature curves in manual bar g (7.25 psi g) maximum 1 1) Available with process connection options AA... HD & Antenna Versions A... H only 2) Available with process connection options JA... MH & Antenna Versions J... P only 3) Available For antenna versions A and E only, max. range 10 m (32.8 ft), dk > 3. Can measure dk >1.6 [20 m (65.6 ft)] when mounted in a stillpipe/ bypass. ) Siemens Milltronics type flange (flange bolting patterns and facings dimensionally correspond to the applicable ASME B16.5, or EN , or JIS B 2220 standard), see operating instructions for details 5) Applicable with communication option 2 only We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 9/5 in the appendix. Siemens FI 01 June 2015 /217

218 Continuous level measurement - Radar transmitters SITRANS LR250 Horn Antenna Order code Further designs Please add "-Z" to and specify Order code(s). Plug M12 with mating Connector 1)2)3) A50 Plug 7/8" with mating Connector 2)3)) A55 Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Y15 Measuring-point number/identification (max. 27 characters); specify in plain text Manufacturer's Test Certificate: M to DIN 55350, C11 Part 18 and to ISO 9000 Inspection certificate 3.1 of EN 1020 C12 Functional Safety (SIL 2). Device suitable for use in C20 accordance with IEC and IEC )5) Namur NE3 compliant, device preset to failsafe N07 <3.6mA 5) Operating Instructions for HART/mA device English A5E German A5E French A5E Note: The Operating Instructions should be ordered as a separate line item on the order. Compact Operating Instructions for HART/mA device English, French, German, Spanish, Italian, Dutch, A5E Danish, Finnish, Greek, Portuguese (Portugal), Swedish English, Bulgarian, Czech, Estonian, Hungarian, A5E Latvian, Lithuanian, Polish, Romanian, Slovakian, Slovenian English, Portuguese (Brazil), Chinese A5E This device is shipped with the Siemens Milltronics manual DVD containing the ATEX Compact Operating Instructions and Operating Instructions library. Operating Instructions for PROFIBUS PA device English A5E German A5E French A5E Note: The Operating Instructions should be ordered as a separate line item on the order. Compact Operating Instructions for PROFIBUS PA device English, French, German, Spanish, Italian, Dutch, A5E Danish, Finnish, Greek, Portuguese (Portugal), Swedish English, Bulgarian, Czech, Estonian, Hungarian, A5E Latvian, Lithuanian, Polish, Romanian, Slovakian, Slovenian English, Portuguese (Brazil), Chinese A5E30662 This device is shipped with the Siemens Milltronics manual DVD containing the ATEX Compact Operating Instructions and Operating Instructions library. Operating Instructions for FOUNDATION Fieldbus device English German French Note: The Operating Instructions should be ordered as a separate line item on the order. Compact Operating Instructions for FOUNDATION Fieldbus device English, French, German, Spanish, Italian, Dutch, Danish, Finnish, Greek, Portuguese (Portugal), Swedish English, Bulgarian, Czech, Estonian, Hungarian, Latvian, Lithuanian, Polish, Romanian, Slovakian, Slovenian English, Portuguese (Brazil), Chinese This device is shipped with the Siemens Milltronics manual DVD containing the ATEX Compact Operating Instructions and Operating Instructions library. Accessories Handheld programmer, Intrinsically safe, EEx ia HART modem/usb (for use with a PC and SIMATIC PDM) One metallic cable gland M20x1.5, rated C ( F), HART (two are required) One metallic cable gland M20x1.5, rated C ( F), PROFIBUS PA and FOUNDATION Fieldbus (two are required) 6) FDA approved FKM o-ring for 2" G (BSPP) process connections C ( F) SITRANS RD100, loop powered display - see Chapter 7 SITRANS RD200, universal input display with Modbus conversion - see Chapter 7 SITRANS RD300, dual line display with totalizer and linearization curve and Modbus conversion - see Chapter 7 SITRANS RD500 web, universal remote monitoring solution for instrumentation - see Chapter 7 For applicable back up point level switch - see point level measurement section A5E A5E A5E A5E A5E A5E ML1930-1BK 7MF997-1DB 7ML1930-1AP 7ML1930-1AQ 7ML1830-3AN 7ML ML ML ML ) Available with enclosure option 1 only 2) To be used with communication options 1 and 3 only. Connector has IP67 rating. 3) Available with approval options A and B. Available with approval option C for use on intrinsically safe applications only. Not rated for dust Ex. ) Available with enclosure option 0 only 5) Applicable to communication option 2 only 6) For use with communication option 1 and 3 only We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 9/5 in the appendix. /218 Siemens FI 01 June 2015

219 Continuous level measurement - Radar transmitters SITRANS LR250 Horn Antenna Characteristic curves Maximum flange and process temperatures versus allowable ambient temperature Ambient temperature ( C) C C Process flange surface temperature ( C) SITRANS LR250 Ambient/Process Flange Surface Temperature Curve Siemens FI 01 June 2015 /219

220 Continuous level measurement - Radar transmitters SITRANS LR250 Horn Antenna Dimensional drawings Threaded Horn Antenna 50 (2.0) ½" NPT cable entry (or alternatively, M20 cable gland) Threaded cover 15 (6.1) 167 (6.6) 90 (3.5) Enclosure/ electronics 28 (1.1)* 196 (7.7) Retaining collar Process device tag Horn 159 (6.26) Sensor reference point See dimension table for height to sensor reference point Antenna O.D. Antenna O.D. *28 mm (1.1) for 1.5 inch and 2 inch, 2 mm (1.65) for 3 inch Antenna Type Antenna O.D. 1-1/2" threaded connection Height to sensor reference point 2" threaded connection 3" threaded connection Beam angle Measurement range 1.5" horn 2" horn (5.57) 17.8 (5.88) 135 (5.3) N/A N/A 166 (6.55) N/A 180 (7.09) 19 degrees 15 degrees 10 m (32.8 ft) 20 m (65.6 ft) 3" horn 17.8 (6.9) N/A 199 (7.85) 213 (8.39) 10 degrees 20 m (65.6 ft) " horn 19.8 (7.73) N/A 25 (10) 268 (10.55) 8 degrees 20 m (65.6 ft) SITRANS LR250 Threaded Horn Antenna, dimensions in mm (inch) /220 Siemens FI 01 June 2015

221 Continuous level measurement - Radar transmitters SITRANS LR250 Horn Antenna Threaded Horn Antenna with Extension 50 (2.0) ½" NPT cable entry (or alternatively, M20 cable gland) Threaded cover 15 (6.1) 167 (6.6) 90 (3.5) Enclosure/ electronics 196 (7.7) Retaining collar 159 (6.26) Sensor reference point 28 (1.1)* Process device tag See dimension table for height to sensor reference point Antenna O.D. Horn Antenna O.D. *28 mm (1.1) for 1.5 inch and 2 inch, 2 mm (1.65) for 3 inch Antenna Type 1.5" horn 2" horn 3" horn " horn Antenna O.D (5.57) 17.8 (5.88) 17.8 (6.9) 19.8 (7.73) 1-1/2" threaded connection 235 (9.3) N/A N/A N/A Height to sensor reference point 2" threaded connection N/A 266 (10.55) 299 (11.85) 35 (1) 3" threaded connection N/A 280 (11.09) 313 (12.39) 368 (1.55) Beam angle 19 degrees 15 degrees 10 degrees 8 degrees Measurement range 10 m (32.8 ft) 20 m (65.6 ft) 20 m (65.6 ft) 20 m (65.6 ft) SITRANS LR250 Threaded Horn Antenna with Extension, dimensions in mm (inch) Siemens FI 01 June 2015 /221

222 Continuous level measurement - Radar transmitters SITRANS LR250 Horn Antenna Flanged Horn 50 (2.0) ½" NPT cable entry (or alternatively, M20 cable gland) Threaded cover 15 (6.1) Enclosure/ electronics 167 (6.6) 90 (3.5) Name-plate 227 (8.9) Flange Retaining collar 190 (7.8) horn Sensor reference point Process connection tag 50 (2) nominal 80 (3) nominal 100 () nominal horn O.D. Nominal Horn Size 50 (2) 80 (3) 100 () Horn O.D (5.88) 17.8 (6.9) 19.8 (7.73) Height to sensor reference point Stainless steel flange raised or Optional alloy flange flat-faced (5.32) (5.) (6.62) (6.7) (8.79) (8.90) Beam angle 15 degrees 10 degrees 8 degrees Measurement range 20 m (65.6 ft) 20 m (65.6 ft) 20 m (65.6 ft) SITRANS LR250 Flanged Horn Antenna, dimensions in mm (inch) /222 Siemens FI 01 June 2015

223 Continuous level measurement - Radar transmitters SITRANS LR250 Horn Antenna Flanged Horn with Extension 50 (2.0) ½" NPT cable entry (or alternatively, M20 cable gland) Threaded cover 15 (6.1) Enclosure/ electronics 167 (6.6) 90 (3.5) 227 (8.9) Flange Name-plate Retaining collar 190 (7.8) Sensor reference point Process connection tag Horn (9.32) (10.62) (12.79) 50 (2) nominal 80 (3) nominal 100 () nominal Horn O.D. Nominal Horn Size 50 (2) 80 (3) Horn O.D (5.88) 17.8 (6.9) Height to sensor reference point Stainless steel flange raised or Optional alloy flange flat-faced (9.32) (9.) (10.62) (10.7) Beam angle 15 degrees 10 degrees Measurement range 20 m (65.6 ft) 20 m (65.6 ft) 100 () 19.8 (7.73) (12.79) (12.90) 8 degrees 20 m (65.6 ft) SITRANS LR250 Flanged Horn Antenna with Extension, dimensions in mm (inch) Siemens FI 01 June 2015 /223

224 Continuous level measurement - Radar transmitters SITRANS LR250 Horn Antenna Schematics Connect the wires to the terminals as shown: the polarity is identified on the terminal block. Hand Programmer Shield for HART, PROFIBUS PA, and Part number: Gland FOUNDATION Fieldbus 7ML1930-1BK Intrinsically Safe versions only. Notes: 1. DC terminal shall be supplied from a source providing electrical isolation between the input and output, to meet the applicable safety requirements of IEC All field wiring must have insulation suitable for rated input voltages. 3. Use shielded twisted pair cable ( AWG) for HART version.. Separate cables and conduit may be required to conform to standard instrumentation wiring practices or electrical codes. SITRANS LR250 connections /22 Siemens FI 01 June 2015

225 Continuous level measurement - Radar transmitters SITRANS LR250 Specials Selection and ordering data SITRANS LR250 Specials SITRANS LR250 Specials SITRANS LR250 horn version enclosures (PROFIBUS PA models) SITRANS LR250 horn version enclosures (< 3.6 ma start-up HART) LR250 horn version enclosure with board stack, NPT cable inlet, approval option A, with PROFIBUS PA communication, no process connection LR250 horn version enclosure with board stack, M20 cable inlet, approval option A, with PROFIBUS PA communication, no process connection LR250 horn version enclosure with board stack, NPT cable inlet, approval option B, with PROFIBUS PA communication, no process connection LR250 horn version enclosure with board stack, M20 cable inlet, approval option B, with PROFIBUS PA communication, no process connection LR250 horn version enclosure with board stack, NPT cable inlet, approval option C, with PROFIBUS PA communication, no process connection LR250 horn version enclosure with board stack, M20 cable inlet, approval option C, with PROFIBUS PA communication, no process connection LR250 horn version enclosure with board stack, M20 cable inlet, approval option C, with PROFIBUS PA communication, no process connection LR250 horn version enclosure with board stack, M20 cable inlet, approval option D, with PROFIBUS PA communication, no process connection LR250 enclosure with board stack, NPT cable inlet, approval option B, with FOUNDATION FIELDBUS communication, no process connection LR250 enclosure with board stack, NPT cable inlet, approval option D, with FOUNDATION FIELDBUS communication, no process connection LR250 enclosure with board stack, M20 cable inlet, approval option E, with FOUNDATION FIELDBUS communication, no process connection SITRANS LR250 horn version enclosures (FOUNDATION Fieldbus models) A5E A5E A5E A5E A5E A5E A5E A5E A5E A5E A5E SITRANS LR250 horn version enclosure with board stack, M20 cable inlet, approval option A, with HART communication start-up at < 3.6 ma, no process connection SITRANS LR250 horn version enclosure with board stack, M20 cable inlet, approval option C, with HART communication start-up at < 3.6 ma, no process connection SITRANS LR250 horn version enclosure with board stack, M20 cable inlet, approval option E, with HART communication start-up at < 3.6 ma, no process connection SITRANS LR250 horn version enclosure with board stack, M20 cable inlet, approval option F, with HART communication start-up at < 3.6 ma, no process connection SITRANS LR250 horn version enclosure with board stack, M20 cable inlet, approval option G, with HART communication start-up at < 3.6 ma, no process connection LR250 horn version enclosure with board stack, NPT cable inlet, approval option A, with HART communication start-up at < 3.6 ma, no process connection LR250 horn version enclosure with board stack, NPT cable inlet, approval option B, with HART communication start-up at < 3.6 ma, no process connection LR250 horn version enclosure with board stack, NPT cable inlet, approval option D, with HART communication start-up at < 3.6 ma, no process connection LR250 horn version enclosure with board stack, NPT cable inlet, approval option H, with HART communication start-up at < 3.6 ma, no process connection SITRANS LR250 horn antenna and extension kits 38 mm (1.5 inch) horn antenna kit, 1.5" Process Connections only A5E A5E A5E A5E A5E A5E A5E A5E A5E A5E mm ( inch) horn antenna extension kit, 1.5" Process Connections only A5E mm (2 inch) stainless steel 316L horn antenna kit A5E LR250 horn version enclosure with board stack, M20 cable inlet, approval option C, with FOUNDATION Fieldbus communication, no process connection LR250 horn version enclosure with board stack, NPT cable inlet, approval option A, with FOUNDATION Fieldbus communication, no process connection LR250 horn version enclosure with board stack, M20 cable inlet, approval option A, with FOUNDATION Fieldbus communication, no process connection LR250 horn version enclosure with board stack, NPT cable inlet, approval option C, with FOUNDATION Fieldbus communication, no process connection A5E A5E A5E A5E mm (3 inch) stainless steel 316L horn antenna kit A5E mm ( inch) stainless steel 316L horn antenna kit A5E mm ( inch) horn antenna extension kit, A5E mm (2 inch), 75 mm (3 inch) and 100 mm ( inch) process connection 50 mm (2 inch) horn antenna kit, Hastelloy C-22 A5E mm (3 inch) horn antenna kit, Hastelloy C-22 A5E mm ( inch) horn antenna kit, Hastelloy C-22 A5E Dupont 1Gr Polyback, PTFE grease kit A5E LR250 lid with O-ring A5E Siemens FI 01 June 2015 /225

226 Continuous level measurement - Radar transmitters SITRANS LR250 threaded PVDF antenna Overview SITRANS LR250 with threaded PVDF antenna is a 2-wire, 25 GHz pulse radar level transmitter for continuous monitoring of liquids and slurries in storage and process vessels including corrosives or aggressive materials, to a range of 10 m (32.8 ft) or 20 m (66 ft) when used in a stilling pipe. Benefits Fully insulated PVDF antenna design for use in chemical and sanitary environments where aggressive and corrosive materials are used Cost effective replacement for transmitters made of exotic materials Graphical local user interface (LUI) makes operation simple with plug-and-play setup using the intuitive Quick Start Wizard LUI displays echo profiles for diagnostic support 25 GHz high frequency and 50 mm (2 inch) process connection/antenna allow for easy mounting in nozzles Insensitive to mounting location and obstructions, and less sensitive to nozzle interference Short blanking distance for improved minimum measuring range to 50 mm (2 inch) from the end of the antenna Communication using HART or PROFIBUS PA, or FOUNDATION Fieldbus Process Intelligence signal processing for improved measurement reliability and Auto False-Echo Suppression of fixed obstructions Programming using infrared Intrinsically Safe handheld programmer or over a network using SIMATIC PDM, Emerson AMS, or Field Device Tools, such as PACTware or Fieldcare via SITRANS DTM. Suitable for use in Safety Related Systems in accordance with IEC 61508/61511 (SIL-2) 3 mm (0.118 inch) accuracy in accordance with IEC Application SITRANS LR250 includes a graphical local user interface (LUI) that improves setup and operation by including an intuitive Quick Start Wizard, and echo profile displays for diagnostic support. Startup is easy using the Quick Start wizard with a few parameters required for basic operation. The 25 GHz frequency creates a narrow, focused beam allowing for smaller antenna options and decreasing sensitivity to obstructions. SITRANS LR250 s unique design allows safe and simple programming using the Intrinsically Safe handheld programmer without having to open the instrument s lid. SITRANS LR250 measures superbly in small vessels and in tanks/vessels up to 10 m (32 ft) on materials with dk > 3 or 20 m (66 ft) when used in a stilling pipe with dk 1.6. Key Applications: liquid bulk storage tanks, process vessels with agitators, vaporous liquids, temperatures to 80 C (176 F), corrosive and aggressive materials and applications requiring functional safety /226 Siemens FI 01 June 2015

227 Continuous level measurement - Radar transmitters SITRANS LR250 threaded PVDF antenna Configuration Installation Note: Beam angle is the width of the cone where the energy density is half of the peak energy density. The peak energy density is directly in front of and in line with the antenna. There is a signal transmitted outside of the beam angle; therefore false targets may be detected. Mounting unit on bypass Orient front or back of device toward vent. 19 Mounting unit on stilling well Orient front or back of device toward stillpipe slots. Mounting unit on vessel Mounting on a nozzle min. 10 (0.) SITRANS LR250 PVDF antenna installation, dimensions in mm (inch) Siemens FI 01 June 2015 /227

228 Continuous level measurement - Radar transmitters SITRANS LR250 threaded PVDF antenna Technical specifications Mode of operation Measuring principle Radar level measurement Frequency K-band (25.0 GHz) Minimum measuring range 50 mm (2 inch) from end of antenna Maximum measuring range 10 m (32.8 ft) or 20 m (66 ft) when used in a stilling pipe with dk 1.6 Output HART Version 5.1 Analog output ma Accuracy ± 0.02 ma Fail-safe Programmable as high low or hold (loss of echo) NE 3 programmable PROFIBUS PA Profile 3.1 Function blocks 2 Analog Input (AI) FOUNDATION Fieldbus H1 Functionality Basic or LAS Version ITK Function blocks 2 Analog Input (AI) Performance (according to reference conditions IEC ) Maximum measured error > 500 mm from sensor reference point: 3 mm (0.118 inch) < 500 mm from sensor reference point: 25 mm (1 inch) Influence of ambient temperature < %/K Rated operating conditions Installation conditions Location Indoor/outdoor Ambient conditions (enclosure) Ambient temperature C ( F) Installation category I Pollution degree Medium conditions Dielectric constant ε r 3 (1.6 in stillpipe) Process temperature C ( F) at process connection (Is suitable for CIP at 120 C for 1/2 hr max.) Process pressure Up to 5 bar g (72 psi g) temperature dependent. See Pressure/Temperature curves for more information Design Enclosure Material Aluminum, polyester powder-coated Cable inlet 2 x M20x1.5 or 2 x ½" NPT Degree of protection Type X/NEMA X, Type 6/NEMA 6, IP67, IP68 Weight approximately 3.3 kg (7.27 lb) Display (local) Graphic local user interface including quick start wizard and echo profile display Antenna Material PVDF (Polyvinylidene fluoride) Dimensions (nominal sizes) 2 inch (8 mm) Process connections Process connection 2" NPT [(Taper), ASME B1.20.1] 2" [(BSPT), EN 10226] 2" [(BSPP), EN ISO 228-1] Power supply ma/hart Nominal 2 V DC (max. 30 V DC) with max. 550 Ω PROFIBUS PA 15 ma per IEC FOUNDATION Fieldbus 20.0 ma per IEC Certificates and approvals General Radio CSA US/C, CE, FM, NE 21, RCM FCC, Industry Canada and Europe ETSI EN , RCM Hazardous Explosion Proof (Brazil) INMETRO Ex d ia mb IIC T Ga/Gb, Ex ia ta IIIC T100 C Da Increased Safety (Brazil) INMETRO Ex e ia mb IIC T Ga/Gb, Ex ia ta IIIC T100 C Da Intrinsically Safe (Brazil) INMETRO Ex ia IIC T Ga, Ex ia ta IIIC T100 C Da Explosion Proof (Canada/USA) CSA/FM Class I, Div. 1, Groups A, B, C, D; Class II, Div. 1, Groups E, F, G; Class III T Intrinsically Safe (Canada/USA) CSA/FM Class I, Div. 1, Groups A, B, C, D; Class II, Div. 1, Groups E, F, G; Class III T Non-incendive (Canada/USA) CSA/FM Class I, Div. 2, Groups A, B, C, D T5 Flame Proof/Increased Safety (China) Intrinsically Safe (China) Non-sparking (China) Intrinsically Safe (Europe) Ex d ia mb IIC T Ga/Gb, Ex e ia mb IIC T Ga/Gb, Ex iad 20 T90 IP67 DIP A20 T A 90 ºC Ex ia IIC T Ga, Ex iad 20 T90 IP67 DIP A20 T A 90 ºC NEPSI Ex na IIC T Gc ATEX II 1G Ex ia IIC T Ga ATEX II 1D Ex ia ta IIC T100 C Da ATEX II 3G Ex na IIC T Gc Non-sparking/Energy Limited (Europe) Flame Proof (International/Europe) IECEx/ATEX II 1/2 GD, 1D, 2D, Ex d mb ia IIC T Ga/Gb, Ex ia ta IIC T100 C Da Increased Safety (International/Europe) Intrinsically Safe (International) Explosion Proof (Russia) Increased Safety (Russia) Intrinsically Safe (Russia) Marine Functional Safety IECEx/ATEX II 1/2 GD, 1D, 2D, Ex e mb ia IIC T Ga/Gb, Ex ia ta IIIC T100 C Da IECEx/ATEX II 1 G Ex ia IIC T Ga, IECEX/ATEX II 1D Ex ia ta IIC T100 C Da GOST-R Ex d GOST-R Ex e GOST-R Ex ia Lloyd's Register of Shipping ABS Type Approval Bureau Veritas SIL-2 suitable in accordance with IEC 61508/61511 Programming Intrinsically Safe Siemens handheld Infrared receiver programmer Approvals for handheld programmer IS model: ATEX II 1 GD Ex ia IIC T Ga Ex ia D 20 T135 C T a = C CSA/FM Class I, II, III, Div. 1, Groups A, B, C, D, E, F, G, T6 T a = +50 C IECEx SIR Handheld communicator HART communicator 375/75 PC SIMATIC PDM Emerson AMS SITRANS DTM (for connection into FDT, such as PACTware or Fieldcare) Display (local) Graphic local user interface including quick start wizard and echo profile displays /228 Siemens FI 01 June 2015

229 Continuous level measurement - Radar transmitters SITRANS LR250 threaded PVDF antenna SITRANS LR250 threaded PVDF antenna 2-wire, 25 GHz pulse radar level transmitter for continuous monitoring of liquids and slurries in storage and process vessels including corrosives or aggressive materials, to a range of 10 m (32.8 ft) or 20m (66ft) when used in a stilling pipe. Click on the for the online configuration in the PIA Life Cycle Portal. 7ML Process Connection and Antenna Material Threaded PVDF antenna Process Connection Type Threaded connections PVDF 2" NPT (ASME B1.20.1) (tapered thread) PA R 2" [(BSPT), EN ] (tapered thread) PB G 2" [(BSPP), EN ISO 228-1] (parallel thread) PC Communication/Output PROFIBUS PA ma, HART, start-up at < 3.6 ma 2 FOUNDATION Fieldbus 3 Enclosure/Cable inlet Aluminum, Epoxy painted 2 x ½" NPT 0 2 x M20x1.5 1 Antenna 2 inch(50 mm) threaded PVDF antenna R Approvals General Purpose, CE, CSA, FM, FCC, R&TTE, RCM A Intrinsically Safe: CSA/FM Class I, Div. 1, Groups A, B B, C, D, Class II, Div.1, Groups E,F, G, Class III T FCC, Industry Canada Intrinsically Safe: IECEx/ATEX II 1 G Ex ia IIC T Ga, C IECEx/ATEX II 1D Ex ia ta IIIC T100 C Da, INMETRO Ex ia IIC T Ga, Ex ia ta IIIC T100 o C Da, CE, R&TTE, RCM Non-incendive: CSA/FM Class I, Div. 2, Groups A, D B, C, D T5, FCC, Industry Canada Non Sparking: ATEX II 3G Ex na IIC T Gc, CE, E R&TTE, RCM Increased Safety: IECEx/ATEX II 1/2 GD,1D, 2D Ex e mb ia IIC T Ga/Gb, Ex ia ta IIIC T100 C F Da, INMETRO Ex e ia mb IIC T Ga/Gb, Ex ia ta IIIC T100 o C Da, CE, R&TTE, RCM 1) Flameproof: IECEx/ATEX II 1/2 GD 1D, 2D Ex d mb G ia IIC T Ga/Gb, Ex ia ta IIIC T100 C Da, INMETRO Ex d ia mb IIC T Ga/Gb, Ex ia ta IIIC T100 o C Da, CE, R&TTE, RCM 1) Explosion proof: CSA/FM Class I, II and III, Div. 1, Groups A, B, C, D, E, F, G, FCC, Industry Canada 1) H Non Sparking: NEPSI Ex na IIC T Gc K Intrinsically Safe: NEPSI Ex ia IIC T Ga, Ex iad 20 L T90 IP67 DIP A20 T A 90 ºC Flameproof: NEPSI Ex d ia mb IIC T Ga/Gb, M Ex iad 20 T90 IP67 DIP A20 T A 90 ºC 1) Increased Safety: NEPSI Ex e ia mb IIC T Ga/Gb, N Ex iad 20 T90 IP67 DIP A20 T A 90 ºC 1) Pressure rating Rating per Pressure/Temperature curves in manual 2 1) Applicable to Communication option 2 only We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 9/5 in the appendix. Order code Further designs Please add "-Z" to and specify Order code(s). Plug M12 with mating Connector 1)2)3) A50 Plug 7/8" with mating Connector 2)3)) A55 Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Y15 Measuring-point number/identification (max. 27 characters); specify in plain text Manufacturer's test certificate: M to DIN 55350, C11 Part 18 and to ISO 9000 Inspection Certificate Type 3.1 per EN 1020 C12 Functional Safety (SIL 2). Device suitable for use C20 in accordance with IEC and IEC )6) Namur NE3 compliant, device preset to failsafe N07 <3.6mA 5) Operating Instructions for HART/mA device English A5E German A5E French A5E Note: The Operating Instructions should be ordered as a separate line item on the order. Compact Operating Instructions for HART/mA device English, French, German, Spanish, Italian, Dutch, A5E Danish, Finnish, Greek, Portuguese (Portugal), Swedish English, Bulgarian, Czech, Estonian, Hungarian, A5E Latvian, Lithuanian, Polish, Romanian, Slovakian, Slovenian English, Portuguese (Brazil), Chinese A5E This device is shipped with the Siemens Milltronics manual DVD containing the ATEX Compact Operating Instructions and Operating Instructions library. Operating Instructions for PROFIBUS PA device English A5E German A5E French A5E Note: The Operating Instructions should be ordered as a separate line item on the order. Compact Operating Instructions for PROFIBUS PA device English, French, German, Spanish, Italian, Dutch, A5E Danish, Finnish, Greek, Portuguese (Portugal), Swedish English, Bulgarian, Czech, Estonian, Hungarian, A5E Latvian, Lithuanian, Polish, Romanian, Slovakian, Slovenian English, Portuguese (Brazil), Chinese A5E30662 This device is shipped with the Siemens Milltronics manual DVD containing the ATEX Compact Operating Instructions and Operating Instructions library. We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 9/5 in the appendix. Siemens FI 01 June 2015 /229

230 Continuous level measurement - Radar transmitters SITRANS LR250 threaded PVDF antenna Operating Instructions for FOUNDATION Fieldbus device English German A5E A5E Accessories Handheld programmer, Intrinsically safe, EEx ia HART modem/usb (for use with a PC and SIMATIC PDM) 7ML1930-1BK 7MF997-1DB French Note: The Operating Instructions should be ordered as a separate line item on the order. Compact Operating Instructions for FOUNDATION Fieldbus device English, French, German, Spanish, Italian, Dutch, Danish, Finnish, Greek, Portuguese (Portugal), Swedish English, Bulgarian, Czech, Estonian, Hungarian, Latvian, Lithuanian, Polish, Romanian, Slovakian, Slovenian English, Portuguese (Brazil), Chinese This device is shipped with the Siemens Milltronics manual DVD containing the ATEX Compact Operating Instructions and Operating Instructions library. A5E A5E A5E A5E One metallic cable gland M20x1.5, rated C ( F), HART One metallic cable gland M20x1.5, rated C ( F), PROFIBUS PA and FOUNDATION Fieldbus 2) FDA approved FKM o-ring for 2" G (BSPP) process connections C ( F) SITRANS RD100, loop powered display - see Chapter 7 SITRANS RD200, universal input display with Modbus conversion - see Chapter 7 SITRANS RD300, dual line display with totalizer and linearization curve and Modbus conversion - see Chapter 7 SITRANS RD500 web, universal remote monitoring solution for instrumentation - see Chapter 7 For applicable back up point level switch - see point level measurement section 7ML1930-1AP 7ML1930-1AQ 7ML1830-3AN 7ML ML ML ML ) Available with Enclosure option 1 only 2) To be used with Communication options 1 and 3 only. Connector has IP67 rating. 3) Available with Approval options A and B. Available with approval option C for use on intrinsically safe applications only. Not rated for dust Ex. ) Available with Enclosure option 0 only 5) Available with communication option 2 only 6) Available with approval options A, B, C, D, E, K and L only Characteristic curves Pressure/Temperature Curve Pressure (bar, gauge) ºC, 5 bar ºC, 2.25 bar Temperature ( C) SITRANS LR250 PVDF antenna pressure/temperature curve /230 Siemens FI 01 June 2015

231 Continuous level measurement - Radar transmitters SITRANS LR250 threaded PVDF antenna Dimensional drawings 50 (2.0) 1/2" NPT cable entry (or alternatively, M20 cable gland) Threaded cover 15 (6.1) 167 (6.6) 90 (3.5) 18 (7.2) Enclosure/ electronics Process connection tag 16 (5.7) 121 (.76) 2" thread Sensor reference point 9.5 (1.9) antenna O.D. Threaded PVDF antenna SITRANS LR250 PVDF antenna, dimensions in mm (inch) Schematics Connect the wires to the terminals as shown: the polarity is identified on the terminal block. Hand Programmer Shield for HART, PROFIBUS PA, and Part number: Gland FOUNDATION Fieldbus 7ML1930-1BK Intrinsically Safe versions only. Notes: 1. DC terminal shall be supplied from a source providing electrical isolation between the input and output, to meet the applicable safety requirements of IEC All field wiring must have insulation suitable for rated input voltages. 3. Use shielded twisted pair cable ( AWG) for HART version.. Separate cables and conduit may be required to conform to standard instrumentation wiring practices or electrical codes. SITRANS LR250 connections Siemens FI 01 June 2015 /231

232 Continuous level measurement - Radar transmitters SITRANS LR250 threaded PVDF Specials Selection and ordering data SITRANS LR250 threaded PVDF Specials SITRANS LR250 threaded PVDF Specials SITRANS LR250 threaded PVDF antenna version enclosures (PROFIBUS PA models) SITRANS LR250 threaded PVDF antenna version enclosures (< 3.6 ma start-up HART models) LR250 threaded PVDF antenna version enclosure with board stack, M20 cable inlet, approval option A, with PROFIBUS PA communication, no process connection A5E LR250 enclosure with board stack, M20 cable inlet, approval option A, with HART communication start-up at < 3.6 ma, no process connection A5E LR250 threaded PVDF antenna version enclosure with board stack, NPT cable inlet, approval option A, with PROFIBUS PA communication, no process connection A5E LR250 enclosure with board stack, NPT cable inlet, approval option A, with HART communication start-up at < 3.6 ma, no process connection A5E LR250 threaded PVDF antenna version enclosure with board stack, NPT cable inlet, approval option B, with PROFIBUS PA communication, no process connection A5E LR250 enclosure with board stack, NPT cable inlet, approval option B, with HART communication start-up at < 3.6 ma, no process connection A5E LR250 threaded PVDF antenna version enclosure with board stack, M20 cable inlet, approval option C, with PROFIBUS PA communication, no process connection A5E LR250 enclosure with board stack, M20 cable inlet, approval option C, with HART communication start-up at < 3.6 ma, no process connection A5E LR250 threaded PVDF antenna version enclosure with board stack, NPT cable inlet, approval option D, with PROFIBUS PA communication, no process connection A5E LR250 enclosure with board stack, NPT cable inlet, approval option D, with HART communication start-up at < 3.6 ma, no process connection A5E LR250 threaded PVDF antenna version enclosure with board stack, M20 cable inlet, approval option E, with PROFIBUS PA communication, no process connection A5E LR250 enclosure with board stack, M20 cable inlet, approval option E, with HART communication start-up at < 3.6 ma, no process connection A5E SITRANS LR250 threaded PVDF antenna version enclosures (FOUNDATION Fieldbus models) LR250 enclosure with board stack, M20 cable inlet, approval option A, with FOUNDATION Fieldbus communication, no process connection LR250 enclosure with board stack, NPT cable inlet, approval option A, with FOUNDATION Fieldbus communication, no process connection LR250 enclosure with board stack, NPT cable inlet, approval option B, with FOUNDATION Fieldbus communication, no process connection LR250 enclosure with board stack, M20 cable inlet, approval option C, with FOUNDATION Fieldbus communication, no process connection LR250 enclosure with board stack, NPT cable inlet, approval option D, with FOUNDATION Fieldbus communication, no process connection A5E A5E A5E A5E A5E LR250 enclosure with board stack, M20 cable inlet, approval option F, with HART communication start-up at < 3.6 ma, no process connection LR250 enclosure with board stack, M20 cable inlet, approval option G, with HART communication start-up at < 3.6 ma, no process connection LR250 enclosure with board stack, NPT cable inlet, approval option H, with HART communication start-up at < 3.6 ma, no process connection SITRANS LR250 threaded PVDF antenna kits Antenna kit 2" NPT threaded PVDF Antenna kit 2" R (BSPT) threaded PVDF Antenna kit 2" G (BSPP) threaded PVDF Kit of hardware parts for LR250 threaded PVDF antenna: consists of O-rings, screws, wavewasher and loctite A5E A5E A5E A5E A5E A5E A5E LR250 enclosure with board stack, M20 cable inlet, approval option E, with FOUNDATION Fieldbus communication, no process connection A5E /232 Siemens FI 01 June 2015

233 Continuous level measurement - Radar transmitters Overview SITRANS LR250 Flanged Encapsulated Antenna SITRANS LR250 measures superbly in small vessels and in tanks/vessels up to 20 m (66 ft) on materials with dk > 1.6. Key Applications: liquid bulk storage tanks, process vessels with agitators, vaporous liquids, temperatures to 170 C (338 F), corrosive and aggressive materials and applications where ease of cleaning is required, such as food or fine chemicals. Configuration Installation SITRANS LR250 with flanged encapsulated antenna is a 2-wire, 25 GHz pulse radar level transmitter for continuous monitoring of liquids and slurries in storage and process vessels including corrosives or aggressive materials, to a range of 20 m (66 ft) (antenna dependent). Note: Beam angle is the width of the cone where the energy density is half of the peak energy density. The peak energy density is directly in front of and in line with the antenna. There is a signal transmitted outside of the beam angle; therefore false targets may be detected. 3"/DN 80/80A or larger 9.6 2"/DN 50 /50A 12.8 Benefits Fully encapsulated horn antenna design with FDA approved TFM 1600 PTFE lens for use in chemical and sanitary environments where aggressive and corrosive materials are used Cost effective replacement for transmitters made of exotic materials Graphical local user interface (LUI) makes operation simple with plug-and-play setup using the intuitive Quick Start Wizard LUI displays echo profiles for diagnostic support 25 GHz high frequency and 50 mm (2 inch) process connection/antenna allow for easy mounting Insensitive to mounting location and obstructions, and less sensitive to nozzle interference Short blanking distance for improved minimum measuring range to 50 mm (2 inch) from the end of the antenna Communication using HART, PROFIBUS PA, or FOUNDATION Fieldbus Process Intelligence signal processing for improved measurement reliability and Auto False-Echo Suppression of fixed obstructions Programming using infrared Intrinsically Safe handheld programmer or over a network using SIMATIC PDM, Emerson AMS, or Field Device Tools, such as PACTware or Fieldcare via SITRANS DTM Functional Safety (SIL 2). Device suitable for use in accordance with IEC and IEC Application SITRANS LR250 includes a graphical local user interface (LUI) that improves setup and operation by including an intuitive Quick Start Wizard, and echo profile displays for diagnostic support. Startup is easy using Quick Start Wizard with a few parameters required for basic operation. The 25 GHz frequency creates a narrow, focused beam allowing for smaller antenna options and decreasing sensitivity to obstructions. SITRANS LR250's unique design allows safe and simple programming using the Intrinsically Safe handheld programmer without having to open the instrument's lid. Mounting unit on bypass Orient front or back of device toward vent. Mounting unit on vessel Mounting unit on stilling well Orient front or back of device toward stillpipe slots. Mounting on a nozzle A A B* Ø50 (2) 500 (20) max. Ø80 (3) 500 (20) max. Ø100 () 500 (20) max. Ø150 (6) 500 (20) max. *Reference conditions B SITRANS LR250 flanged encapsulated antenna installation, dimensions in mm (inch) Siemens FI 01 June 2015 /233

234 Continuous level measurement - Radar transmitters SITRANS LR250 Flanged Encapsulated Antenna Technical specifications Mode of operation Measuring principle Radar level measurement Frequency K-band (25.0 GHz) Minimum measuring range 50 mm (2 inch) from end of antenna Maximum measuring range 20 m (66 ft) Output HART Version 5.1 Analog output ma Accuracy ± 0.02 ma Fail-safe Programmable as high low or hold (loss of echo) NE 3 programmable PROFIBUS PA Profile 3.01 Function blocks 2 Analog Input (AI) FOUNDATION Fieldbus H1 Functionality Basic or LAS Version ITK Function blocks 2 Analog Input (AI) Performance (according to reference conditions IEC ) Maximum measured error > 500 mm from sensor reference point: 3 mm (0.118 inch) < 500 mm from sensor reference point: 25 mm (1 inch) Influence of ambient temperature < %/K Rated operating conditions Installation conditions Location Indoor/outdoor Ambient conditions (enclosure) Ambient temperature C ( F) Installation category I Pollution degree Medium conditions Dielectric constant ε r 1.6 (antenna dependent) Process temperature C ( F) at process connection Process pressure See Pressure/Temperature curves for more information (page /237) Design Enclosure Material Aluminum, polyester powder-coated Cable inlet 2 x M20x1.5 or 2 x ½" NPT Degree of protection Type X/NEMA X, Type 6/NEMA 6, IP67, IP68 Weight (dependent on process connection) Display (local) Antenna Material Dimensions (nominal sizes) Approx. 7 kg (15.3 lb) for 2" Class 150 ASME B16.5 raised face flange (smallest size) Approx kg (39.02 lb) for 6" Class 150 ASME B16.5 raised face flange (largest size) Graphic local user interface including quick start wizard and echo profile display Stainless Steel 316L (1.35 or 1.0) and TFM 1600 PTFE Lens (lens is the only wetted part) 8 mm (2 inch), 80 mm (3 inch), 100 mm ( inch), 150 mm (6 inch) Process connections Flanged connection Raised Face 2, 3,, 6" Class 150 ASME B A, 80A, 100A, 150A 10K JIS B 2220 DN 50, DN 80, DN 100 & DN 150 PN 10/16 EN type B1 Power supply ma/hart Nominal 2 V DC (max. 30 V DC) with max. 550 Ω PROFIBUS PA 15 ma Per IEC FOUNDATION Fieldbus 20.0 ma Per IEC Certificates and approvals General CSA US/C, CE, FM, NE 21, RCM Radio FCC, Industry Canada and Europe ETSI EN , RCM Hazardous Explosion Proof (Brazil) INMETRO Ex d ia mb IIC T Ga/Gb, Ex ia ta IIIC T100 C Da Increased Safety (Brazil) INMETRO Ex e ia mb IIC T Ga/Gb, Ex ia ta IIIC T100 C Da Intrinsically Safe (Brazil) INMETRO Ex ia IIC T Ga, Ex ia ta IIIC T100 C Da Explosion Proof (Canada/USA) CSA/FM Class I, Div. 1, Groups A, B, C, D; Class II, Div. 1, Groups E, F, G; Class III T Intrinsically Safe (Canada/USA) CSA/FM Class I, Div. 1, Groups A, B, C, D; Class II, Div. 1, Groups E, F, G; Class III T Non-incendive (Canada/USA) CSA/FM Class I, Div. 2, Groups A, B, C, D T5 Flame Proof/Increased Safety NEPSI Ex d ia mb IIC T Ga/Gb, (China) Ex e ia mb IIC T Ga/Gb, Ex iad 20 T90 IP67 DIP A20 T A 90 ºC Intrinsically Safe (China) NEPSI Ex ia IIC T Ga, Ex iad 20 T90 IP67 DIP A20 T A 90 ºC Non-sparking/Energy Limited NEPSI Ex na IIC T Gc (China) Intrinsically Safe (Europe) ATEX II 1G Ex ia IIC T Ga ATEX II 1D Ex ia ta IIIC T100 C Da Non-sparking/Energy Limited ATEX II 3G Ex na IIC T Gc (Europe) Flame Proof (International/Europe) IECEx/ATEX II 1/2 GD, 1D, 2D Ex d mb ia IIC T Ga/Gb, Ex ia ta IIC T100 C Da Increased Safety (International/Europe) Intrinsically Safe (International) Explosion Proof (Russia) Increased Safety (Russia) Intrinsically Safe (Russia) Marine Functional Safety IECEx/ATEX II 1/2 GD, 1D, 2D, Ex e mb ia IIC T Ga/Gb, Ex ia ta IIIC T100 C Da IECEx/ATEX II 1 G Ex ia IIC T Ga, IECEx/ATEX II 1D Ex ia ta IIIC T100 C Da GOST-R Ex d GOST-R Ex e GOST-R Ex ia Lloyd s Register of Shipping ABS Type Approval Bureau Veritas SIL-2 suitable in accordance with IEC 61508/61511 /23 Siemens FI 01 June 2015

235 Continuous level measurement - Radar transmitters SITRANS LR250 Flanged Encapsulated Antenna Programming Infrared receiver IS model: ATEX II 1 GD Ex ia IIC T Ga Ex ia D 20 T135 C T a = C CSA/FM Class I, II, III, Div. 1, Groups A, B, C, D, E, F, G, T6 T a = 50 C IECEx SIR Handheld communicator HART communicator 375/75 PC SIMATIC PDM Emerson AMS SITRANS DTM (for connection into FDT, such as PACTware or Fieldcare) Display (local) Graphic local user interface including quick start wizard and echo profile displays Intrinsically Safe Siemens handheld programmer Approvals for handheld-programmer SITRANS LR250 flanged encapsulated antenna 2-wire, 25 GHz pulse radar level transmitter for continuous monitoring of liquids and slurries in 7ML storage and process vessels including high temperature and pressure, to a range of 20 m (66 ft) (antenna dependant). Ideal for corrosive, aggressive and low dielectric media. Click on the for the online configuration in the PIA Life Cycle Portal. Process Connection Material Stainless steel 1.0/ Process Connection Type Flanged Process Connection Types (stainless steel 1.0/1.35) 2" Class 150 ASME B16.5 raised face 1) BF 3" Class 150 ASME B16.5 raised face BG " Class 150 ASME B16.5 raised face BH 6" Class 150 ASME B16.5 raised face BJ 50A 10K JIS B 2220 raised face 1) FD 80A 10K JIS B 2220 raised face FE 100A 10K JIS B 2220 raised face FF 150A 10K JIS B 2220 raised face FG DN 50 PN 10/16 EN type B1 raised face 1) GA DN 80 PN 10/16 EN type B1 raised face GB DN 100 PN 10/16 EN type B1 raised face GC DN 150 PN 10/16 EN type B1 raised face GD Communication/Output PROFIBUS PA ma, HART, start-up at < 3.6 ma 2 FOUNDATION Fieldbus 3 Enclosure/Cable inlet Aluminum, Epoxy painted 2 x ½" NPT 0 2 x M20x1.5 1 Antenna lens material TFM 1600 PTFE Flush Lens A Approvals General Purpose, CE, CSA, FM, FCC, R&TTE, A RCM Intrinsically Safe: CSA/FM Class I, Div. 1, Groups A, B B, C, D, Class II, Div.1, Groups E, F, G, Class III T FCC, Industry Canada Intrinsically Safe: IECEx/ATEX II 1 G Ex ia IIC T Ga, C IECEx/ATEX II 1D Ex ia ta IIIC T100 C Da, INMETRO Ex ia IIC T Ga, Ex ia ta IIIC T100 o C Da, CE, R&TTE, RCM Non-incendive: CSA/FM Class I, Div. 2, Groups A, B, D C, D T5, FCC, Industry Canada Non Sparking: ATEX II 3G Ex na IIC T Gc, CE, E R&TTE, RCM Increased Safety: IECEx/ATEX II 1/2 GD,1D, F 2D Ex e mb ia IIC T Ga/Gb, Ex ia ta IIIC T100 C Da, INMETRO Ex e ia mb IIC T Ga/Gb, Ex ia ta IIIC T100 o C Da, CE, R&TTE, RCM 2) Flameproof: IECEx/ATEX II 1/2 GD 1D, 2D Ex d mb ia G IIC T Ga/Gb, Ex ia ta IIIC T100 C Da, INMETRO Ex d ia mb IIC T Ga/Gb, Ex ia ta IIIC T100 o C Da, CE, R&TTE, RCM 2) Explosion proof: CSA/FM Class I, II and III, Div. 1, H Groups A, B, C, D, E, F, G, FCC, Industry Canada 2) Non Sparking: NEPSI Ex na IIC T Gc K Intrinsically Safe: NEPSI Ex ia IIC T Ga, L Ex iad 20 T90 IP67 DIP A20 T A 90 ºC Flameproof: NEPSI Ex d ia mb IIC T Ga/Gb, M Ex iad 20 T90 IP67 DIP A20 T A 90 ºC 2) Increased Safety: NEPSI Ex e ia mb IIC T Ga/Gb, Ex iad 20 T90 IP67 DIP A20 T A 90 ºC 2) Pressure rating Rating per Pressure/Temperature curves in 0 instruction manual 1) Maximum range 10 m (32.8 ft), dk > 3 [20 m (66 ft)] and dk > 1.6 when mounted in stillpipe] 2) Applicable with communication option 2 only We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 9/5 in the appendix. N Siemens FI 01 June 2015 /235

236 Continuous level measurement - Radar transmitters SITRANS LR250 Flanged Encapsulated Antenna Order code Further designs Please add "-Z" to and specify Order code(s). Plug M12 with mating Connector 1)2)3) A50 Plug 7/8" with mating Connector 2)3)) A55 Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Y15 Measuring-point number/identification (max. 27 characters); specify in plain text Manufacturer's test certificate: M to DIN 55350, C11 Part 18 and to ISO 9000 Inspection Certificate Type 3.1 per EN 1020 C12 Functional Safety (SIL 2). Device suitable for use in C20 accordance with IEC and IEC )6) Namur NE3 compliant, device preset to failsafe < 3.6 ma 5) N07 Operating Instructions for HART/mA device English A5E German A5E French A5E Note: The Operating Instructions should be ordered as a separate line item on the order. Compact Operating Instructions for HART/mA device English, French, German, Spanish, Italian, Dutch, A5E Danish, Finnish, Greek, Portuguese (Portugal), Swedish English, Bulgarian, Czech, Estonian, Hungarian, A5E Latvian, Lithuanian, Polish, Romanian, Slovakian, Slovenian English, Portuguese (Brazil), Chinese A5E This device is shipped with the Siemens Milltronics manual DVD containing the ATEX Compact Operating Instructions and Operating Instructions library. Operating Instructions for PROFIBUS PA device English A5E German A5E French A5E Note: The Operating Instructions should be ordered as a separate line item on the order. Compact Operating Instructions for PROFIBUS PA device English, French, German, Spanish, Italian, Dutch, A5E Danish, Finnish, Greek, Portuguese (Portugal), Swedish English, Bulgarian, Czech, Estonian, Hungarian, A5E Latvian, Lithuanian, Polish, Romanian, Slovakian, Slovenian English, Portuguese (Brazil), Chinese A5E30662 This device is shipped with the Siemens Milltronics manual DVD containing the ATEX Compact Operating Instructions and Operating Instructions library. Operating Instructions for FOUNDATION Fieldbus device English German French Note: The Operating Instructions should be ordered as a separate line item on the order. Compact Operating Instructions for FOUNDATION Fieldbus device English, French, German, Spanish, Italian, Dutch, Danish, Finnish, Greek, Portuguese (Portugal), Swedish English, Bulgarian, Czech, Estonian, Hungarian, Latvian, Lithuanian, Polish, Romanian, Slovakian, Slovenian English, Portuguese (Brazil), Chinese This device is shipped with the Siemens Milltronics manual DVD containing the ATEX Compact Operating Instructions and Operating Instructions library. Accessories Handheld programmer, Intrinsically safe, EEx ia HART modem/usb (for use with a PC and SIMATIC PDM) One metallic cable gland M20x1.5, rated C ( F), HART (2 are required) 6) One metallic cable gland M20x1.5, rated C ( F), PROFIBUS PA and FOUNDATION Fieldbus (2 are required) 2) SITRANS RD100, loop powered display - see Chapter 7 SITRANS RD200, universal input display with Modbus conversion - see Chapter 7 SITRANS RD300, dual line display with totalizer and linearization curve and Modbus conversion - see Chapter 7 SITRANS RD500 web, universal remote monitoring solution for instrumentation - see Chapter 7 For applicable back up point level switch - see point level measurement section 1) Available with enclosure option 1 only 2) Available with communication options 1 and 3 only 3) Available with approval options A, B, C, and L only ) Available with enclosure option 0 only 5) Applicable with communication option 2 only 6) Available with approval options A, B, C, D, E, K, and L only A5E A5E A5E A5E A5E A5E ML1930-1BK 7MF997-1DB 7ML1930-1AP 7ML1930-1AQ 7ML ML ML ML We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 9/5 in the appendix. /236 Siemens FI 01 June 2015

237 Continuous level measurement - Radar transmitters SITRANS LR250 Flanged Encapsulated Antenna Characteristic curves Pressure/ temperature curve LR250 Flanged Encapsulated Antenna ASME flanged process connections (7ML532) Permitted operating pressures P 30 bar (35 psi) 20 bar (290 psi) 2, 3, and " NPS 6" NPS 10 bar (15 psi) ASME 150 lb Atmospheric Pressure -1 bar (-1.5 psi) -0 F (-0 C) -50 C (-58 F) -29 C (-20 F) 1 F (-10 C) 0 C (32 F) 100 F 200 F (38 C) (93 C) RT 50 C 100 C (122 F) (212 F) Permitted operating temperatures 300 F (19 C) 150 C (302 F) 170 C (338 F) 00 F (20 C) 200 C (392 F) T SITRANS LR250 flanged encapsulated antenna pressure/temperature curve Siemens FI 01 June 2015 /237

238 Continuous level measurement - Radar transmitters SITRANS LR250 Flanged Encapsulated Antenna Pressure/ temperature curve LR250 Flanged Encapsulated Antenna EN flanged process connections (7ML532) Permitted operating pressures P 30 bar (35 psi) DN 150 DN bar (290 psi) DN 50, DN bar (15 psi) PN 16 Atmospheric pressure -1 bar (-1.5 psi) -0 F (-0 C) -50 C (-58 F) -29 C (-20 F) 1 F (-10 C) 0 C (32 F) 100 F 200 F (38 C) (93 C) RT 50 C 100 C (122 F) (212 F) Permitted operating temperatures 300 F (19 C) 150 C (302 F) 170 C (338 F) 00 F (20 C) 200 C (392 F) T SITRANS LR250 flanged encapsulated antenna pressure/temperature curve Pressure/ temperature curve LR250 Flanged Encapsulated Antenna JIS B 2220 flanged process connections (7ML532) Permitted operating pressures P 30 bar (35 psi) 150A 100A 20 bar (290 psi) 50A, 80A -1 bar (-1.5 psi) 10 bar (15 psi) Atmospheric pressure -0 1 (-0 ) (-10 ) -50 (-58 ) -29 (-20 ) 0 (32 ) 100 (38 ) 50 (122 ) 200 (93 ) 100 (212 ) 120 (28 ) Permitted operating temperatures 300 (19 ) 150 (302 ) 170 (338 ) 00 (20 ) 200 (392 ) 10K SITRANS LR250 flanged encapsulated antenna pressure/temperature curve /238 Siemens FI 01 June 2015

239 Continuous level measurement - Radar transmitters SITRANS LR250 Flanged Encapsulated Antenna Dimensional drawings Flanged Encapsulated Antenna 2"/DN 50/50A 50 (2.0) ½" NPT cable entry (or alternatively, M20 cable gland) Threaded cover 153 (6.0) 167 (6.6) Enclosure "B" Retaining collar "D" "A" "C" Flange Sensor ref. point "E" Flange Size 2" DN 50 50A Flange Class 150 lb PN 10/16 10K Flange O.D. 152 (5.98) 165 (6.50) 155 (6.10) Antenna Height to see LR250_E_Installation.cdr Beam Measurement for dim. values. aperture size 50 (1.97) Sensor reference point dimension E 1) 11 (0.3) angle 12.8 Range 10 m (32.8 ft) Dimension A 263 (10.35) Dimension B 178 (7) Dimension C 223 (8.78) Dimension D 27 (10.79) 1) Height from tip of lens to sensor reference point as shown. SITRANS LR250 flanged encapsulated antenna, dimensions in mm (inch) Siemens FI 01 June 2015 /239

240 Continuous level measurement - Radar transmitters SITRANS LR250 Flanged Encapsulated Antenna Flanged Encapsulated Antenna 3"/DN 50/80A or greater 50 (2.0) ½" NPT cable entry (or alternatively, M20 cable gland) Threaded cover 153 (6.0) 167 (6.6) Enclosure "B" Retaining collar "D" "A" "C" Flange Sensor ref. point "E" Flange Size 3" DN 80 80A " DN A 6" DN A Flange Class 150 lb PN 10/16 10K 150 lb PN 10/16 10K 150 lb PN 10/16 10K Flange O.D. 190 (7.8) 200 (7.87) 185 (7.28) 230 (9.06) 220 (8.66) 210 (8.27) 280 (11.02) 285 (11.25) 280 (11.02) Antenna Height to see LR250_E_Installation.cdr Beam Measurement for dim. values. aperture size 75 (2.95) 75 (2.95) 75 (2.95) Sensor reference point dimension E 1) 15 (0.59) 13 (0.51) 15 (0.59) angle 9.6 Range 20 m (65.6 ft) m (65.6 ft) m (65.6 ft) Dimension A 328 (12.91) 328 (12.91) 333 (13.11) Dimension B 178 (7) 178 (7) 178 (7) Dimension C 288 (11.3) 288 (11.3) 293 (11.5) Dimension D 33 (13.5) 33 (13.50) 38 (13.70) 1) Height from tip of lens to sensor reference point as shown. SITRANS LR250 flanged encapsulated antenna, dimensions in mm (inch) /20 Siemens FI 01 June 2015

241 Continuous level measurement - Radar transmitters SITRANS LR250 Flanged Encapsulated Antenna Schematics Connect the wires to the terminals as shown: the polarity is identified on the terminal block. Hand Programmer Shield for HART, PROFIBUS PA, and Part number: Gland FOUNDATION Fieldbus 7ML1930-1BK Intrinsically Safe versions only. Notes: 1. DC terminal shall be supplied from a source providing electrical isolation between the input and output, to meet the applicable safety requirements of IEC All field wiring must have insulation suitable for rated input voltages. 3. Use shielded twisted pair cable ( AWG) for HART version.. Separate cables and conduit may be required to conform to standard instrumentation wiring practices or electrical codes. SITRANS LR250 connections Siemens FI 01 June 2015 /21

242 Continuous level measurement - Radar transmitters SITRANS LR250 Flanged Encapsulated Specials Selection and ordering data SITRANS LR250 flanged encapsulated Specials SITRANS LR250 flanged encapsulated Specials SITRANS LR250 flanged encapsulated antenna version enclosures (PROFIBUS PA models) LR250 flanged encapsulated antenna version (7ML532) enclosure with board stack, M20 cable inlet, approval option A, with PROFIBUS PA communication, no process connection LR250 flanged encapsulated antenna version (7ML532) enclosure with board stack, NPT cable inlet, approval option A, with PROFIBUS PA communication, no process connection LR250 flanged encapsulated antenna version (7ML532) enclosure with board stack, NPT cable inlet, approval option B, with PROFIBUS PA communication, no process connection LR250 flanged encapsulated antenna version (7ML532) enclosure with board stack, M20 cable inlet, approval option C, with PROFIBUS PA communication, no process connection LR250 flanged encapsulated antenna version (7ML532) enclosure with board stack, NPT cable inlet, approval option D, with PROFIBUS PA communication, no process connection LR250 flanged encapsulated antenna version (7ML532) enclosure with board stack, M20 cable inlet, approval option E, with PROFIBUS PA communication, no process connection SITRANS LR250 flanged encapsulated antenna version enclosures (FOUNDATION Fieldbus models) LR250 flanged encapsulated antenna version (7ML532) enclosure with board stack, M20 cable inlet, approval option A, with FOUNDATION Fieldbus communication, no process connection LR250 flanged encapsulated antenna version (7ML532) enclosure with board stack, NPT cable inlet, approval option A, with FOUNDATION Fieldbus communication, no process connection LR250 flanged encapsulated antenna version (7ML532) enclosure with board stack, NPT cable inlet, approval option B, with FOUNDATION Fieldbus communication, no process connection LR250 flanged encapsulated antenna version (7ML532) enclosure with board stack, M20 cable inlet, approval option C, with FOUNDATION Fieldbus communication, no process connection LR250 flanged encapsulated antenna version (7ML532) enclosure with board stack, NPT cable inlet, approval option D, with FOUNDATION Fieldbus communication, no process connection LR250 flanged encapsulated antenna version (7ML532) enclosure with board stack, M20 cable inlet, approval option E, with FOUNDATION Fieldbus communication, no process connection SITRANS LR250 flanged encapsulated antenna version enclosures (< 3.6 ma start-up HART models) LR250 flanged encapsulated antenna version (7ML532) enclosure with board stack, M20 cable inlet, approval option A, with HART communication start-up at < 3.6 ma, no process connection LR250 flanged encapsulated antenna version (7ML532) enclosure with board stack, NPT cable inlet, approval option A, with HART communication start-up at < 3.6 ma, no process connection A5E A5E A5E A5E A5E A5E A5E A5E A5E A5E A5E A5E A5E A5E LR250 flanged encapsulated antenna version (7ML532) enclosure with board stack, NPT cable inlet, approval option B, with HART communication start-up at < 3.6 ma, no process connection LR250 flanged encapsulated antenna version (7ML532) enclosure with board stack, M20 cable inlet, approval option C, with HART communication start-up at < 3.6 ma, no process connection LR250 flanged encapsulated antenna version (7ML532) enclosure with board stack, NPT cable inlet, approval option D, with HART communication start-up at < 3.6 ma, no process connection LR250 flanged encapsulated antenna version (7ML532) enclosure with board stack, M20 cable inlet, approval option E, with HART communication start-up at < 3.6 ma, no process connection LR250 flanged encapsulated antenna version (7ML532) enclosure with board stack, M20 cable inlet, approval option F, with HART communication start-up at < 3.6 ma, no process connection LR250 flanged encapsulated antenna version (7ML532) enclosure with board stack, M20 cable inlet, approval option G, with HART communication start-up at < 3.6 ma, no process connection LR250 flanged encapsulated antenna version (7ML532) enclosure with board stack, NPT cable inlet, approval option H, with HART communication start-up at < 3.6 ma, no process connection SITRANS LR250 flanged encapsulated antenna lens kits Replacement TFM 1600 Lens and Spring Washer Kit for 2" Class 150 ASME B16.5 raised face Replacement TFM 1600 Lens and Spring Washer Kit for 3" Class 150 ASME B16.5 raised face Replacement TFM 1600 Lens and Spring Washer Kit for " Class 150 ASME B16.5 raised face Replacement TFM 1600 Lens and Spring Washer Kit for 6" Class 150 ASME B16.5 raised face Replacement TFM 1600 Lens and Spring Washer Kit for 50A 10K JIS B 2220 raised face Replacement TFM 1600 Lens and Spring Washer Kit for 80A 10K JIS B 2220 raised face Replacement TFM 1600 Lens and Spring Washer Kit for 100A 10K JIS B 2220 raised face Replacement TFM 1600 Lens and Spring Washer Kit for 150A 10K JIS B 2220 raised face Replacement TFM 1600 Lens and Spring Washer Kit for DN 50 PN 10/16 EN type B1 raised face Replacement TFM 1600 Lens and Spring Washer Kit for DN 80 PN 10/16 EN type B1 raised face Replacement TFM 1600 Lens and Spring Washer Kit for DN 100 PN 10/16 EN type B1 raised face Replacement TFM 1600 Lens and Spring Washer Kit for DN 150 PN 10/16 EN type B1 raised face A5E A5E A5E A5E A5E A5E A5E A5E A5E A5E A5E A5E A5E A5E A5E A5E A5E A5E A5E /22 Siemens FI 01 June 2015

243 Continuous level measurement - Radar transmitters SITRANS LR250 Hygienic Encapsulated Antenna Overview The SITRANS LR250 hygienic encapsulated antenna is a 2 wire 25GHz pulse radar level transmitter with sanitary and hygienic approvals for continuous monitoring of liquids, slurries and pastes within the Food, Beverage, chemical, and pharmaceutical industries to a range of 20 m (66 ft) - antenna dependent. (Pictures shown with accessories - sold separately) Application SITRANS LR250 includes a graphical local user interface (LUI) that improves set-up and operation by including an intuitive Quick Start Wizard, and echo profile displays for diagnostic support. Start-up is easy using the Quick Start wizard with few parameters required for basic operation. The 25 GHz frequency creates a narrow, focused beam allowing for smaller antenna options and decreasing sensitivity to obstructions. SITRANS LR250 s unique design allows safe and simple programming using the Intrinsically Safe handheld programmer without having to open the instrument s lid. SITRANS LR250 measures superbly in small vessels and in tanks/vessels up to 20 m (66 ft) on materials with dk > 1.6. Key Applications: applications within the Food, Beverage, Chemical and Pharmaceutical industries where sanitary, aseptic or hygienic approvals are required or easy install/ clean flush antennas are preferable, such as ice cream, fruit juice, milk, beer and pharmaceutical or chemical additives and ingredients. Configuration Installation Benefits Fully encapsulated horn antenna design with FDA approved and USP Class VI compliant, TFM 1600 PTFE lens. < 0.8 μ Ra surface finish for maximum cleanability and hygiene requirements commonly required in sanitary environments Chemically resistant TFM 1600 PTFE lens is also suitable for aggressive or corrosive materials Approved device in accordance with 3-A, EHEDG EL Class I and/or EHEDG EL Aseptic Class I Cost effective replacement for transmitters made of exotic materials Graphical local user interface (LUI) makes operation simple with plug-and-play set-up using the intuitive Quick Start Wizard Industry standard process connections including ISO 2852, DIN 11851, DIN , DIN , DIN and Tuchenhagen Varivent Type F and N LUI displays echo profiles for diagnostic support 25 GHz high frequency and 2 inch (50 mm) process connection/antenna allow for easy mounting Insensitive to mounting location and obstructions, and less sensitive to nozzle interference Communication using HART, PROFIBUS PA, or FOUNDATION Fieldbus Process Intelligence signal processing for improved measurement reliability and Auto False-Echo Suppression of fixed obstructions Programming using infrared Intrinsically Safe handheld programmer or over a network using SIMATIC PDM, Emerson AMS, or Field Device Tools, such as PACTware or Fieldcare via SITRANS DTM. Functional Safety (SIL 2). Device suitable for use in accordance with IEC and IEC Note: Beam angle is the width of the cone where the energy density is half of the peak energy density. The peak energy density is directly in front of and in line with the antenna. There is a signal transmitted outside of the beam angle; therefore false targets may be detected. Mounting unit on vessel 3"/DN 80/80A or larger 9.6 2"/DN 50 /50A 12.8 Mounting on a nozzle d Nozzles should be maximum l/d ratio 1:1 (Eg. 50 mm length, 50 mm diameter) LR250 Hygienic Encapsulated Antenna, dimensions in mm (inch) l Siemens FI 01 June 2015 /23

244 Continuous level measurement - Radar transmitters SITRANS LR250 Hygienic Encapsulated Antenna Technical specifications Mode of Operation Measuring principle Radar level measurement Frequency K-band (25.0 GHz) Minimum measuring range 50 mm (2 inch) from end of antenna Maximum measuring range 20 m (66 ft) Output HART Version 5.1 Analog output ma Accuracy ± 0.02 ma Fail-safe Programmable as high low or hold (loss of echo) NE 3 programmable PROFIBUS PA Profile 3.01 Function blocks 2 Analog Input (AI) FOUNDATION Fieldbus H1 Functionality Basic or LAS Version ITK Function blocks 2 Analog Input (AI) Performance (according to reference conditions IEC ) Maximum measured error > 500 mm from sensor reference point: 3 mm (0.118 inch) < 500 mm from sensor reference point: 25 mm (1 inch) Influence of ambient temperature < %/K Rated operating conditions Installation conditions Location Indoor/outdoor Ambient conditions (enclosure) Ambient temperature C ( F) Installation category I Pollution degree Medium conditions Dielectric constant ε r 1.6 (antenna dependent) Process temperature C ( F) at process connection Process pressure See Pressure/Temperature curves for more information Design Enclosure Material Aluminum, polyester powder coated Cable inlet 2 x M20x1.5 or 2 x ½" NPT Degree of protection Type X/NEMA X, Type 6/NEMA 6, IP67, IP68 Weight (dependent on process connection) Display (local) Antenna Material Lens surface finish (R a ) Approx..7 kg (10. lb) for 2" ISO 2852 (smallest size) Approx. 7.9 kg (17. lb) for DN 100 DIN (largest size) Graphic local user interface including quick start wizard and echo profile display Stainless steel 316L (1.35 or 1.0) and TFM 1600 PTFE Lens (lens is the only wetted part) 0.8 μm Process connections Hygienic/Sanitary connections 2", 3" & " Sanitary Clamp according to ISO 2852 DN 50, DN 80 & DN 100 Aseptic/ Hygienic threaded to DIN [Form A] DN 50, DN 80 & DN 100 Aseptic/ Hygienic flanged to DIN [Form A] DN 50, DN 80 & DN 100 Aseptic/ Hygienic Clamp according to DIN [Form A] DN 50, DN 80 & DN 100 Hygienic Union according to DIN Type F (50 mm) & Type N (68 mm) Tuchenhagen Varivent Power supply ma/hart Nominal 2 V DC (max. 30 V DC) with max. 550 Ω PROFIBUS PA 15 ma Per IEC FOUNDATION Fieldbus 20.0 ma Per IEC Certificates and approvals General CSA US/C, CE, FM, NE 21, RCM Radio FCC, Industry Canada and Europe ETSI EN , RCM Hazardous Explosion Proof (Brazil) INMETRO Ex d ia mb IIC T Ga/Gb, Ex ia ta IIIC T100 C Da Increased Safety (Brazil) INMETRO Ex e ia mb IIC T Ga/Gb, Ex ia ta IIIC T100 C Da Intrinsically Safe (Brazil) INMETRO Ex ia IIC T Ga, Ex ia ta IIIC T100 C Da Explosion Proof (Canada/USA) CSA/FM Class I, Div. 1, Groups A, B, C, D; Class II, Div. 1, Groups E, F, G; Class III T Intrinsically Safe (Canada/USA) CSA/FM Class I, Div. 1, Groups A, B, C, D; Class II, Div. 1, Groups E, F, G; Class III T Non-incendive (Canada/USA) CSA/FM Class I, Div. 2, Groups A, B, C, D T5 Flame Proof/Increased Safety NEPSI Ex d ia mb IIC T Ga/Gb, (China) Ex e ia mb IIC T Ga/Gb, Ex iad 20 T90 IP67 DIP A20 T A 90 ºC Intrinsically Safe (China) NEPSI Ex ia IIC T Ga, Ex iad 20 T90 IP67 DIP A20 T A 90 ºC Non-sparking (China) NEPSI Ex na IIC T Gc Intrinsically Safe (Europe) ATEX II 1G Ex ia IIC T Ga ATEX II 1D Ex ia ta IIIC T100 C Da Non-sparking (Europe) ATEX II 3G Ex na IIC T Gc Flame Proof (International/Europe) IECEx/ATEX II 1/2 GD, 1D, 2D Ex d mb ia IIC T Ga/Gb, Ex ia ta IIC T100 C Da Increased Safety (International/Europe) Intrinsically Safe (International) Explosion Proof (Russia) Increased Safety (Russia) Intrinsically Safe (Russia) Hygienic/Sanitary IECEx/ATEX II 1/2 GD, 1D, 2D, Ex e mb ia IIC T Ga/Gb, Ex ia ta IIIC T100 C Da IECEx/ATEX II 1 G Ex ia IIC T Ga, IECEX/ATEX II 1D Ex ia ta IIIC T100 C Da GOST-R Ex d GOST-R Ex e GOST-R Ex ia EHEDG EL Class I EHEDG EL Aseptic Class I /2 Siemens FI 01 June 2015

245 Continuous level measurement - Radar transmitters SITRANS LR250 Hygienic Encapsulated Antenna Programming Intrinsically Safe Siemens handheld Infrared receiver programmer Approvals for handheld programmer IS model: ATEX II 1 GD Ex ia IIC T Ga Ex ia D 20 T135 C Ta = C CSA/FM Class I, II, III, Div. 1, Groups A, B, C, D, E, F, G, T6 T a = 50 C IECEx SIR Handheld communicator HART communicator 375/75 PC SIMATIC PDM Emerson AMS SITRANS DTM (for connection into FDT, such as PACTware or Fieldcare) Display (local) Graphic local user interface including quick start wizard and echo profile displays Siemens FI 01 June 2015 /25

246 Continuous level measurement - Radar transmitters SITRANS LR250 Hygienic Encapsulated Antenna SITRANS LR250 hygienic encapsulated antenna 2-wire, 25 Ghz pulse radar level transmitter for continuous 7ML A 7 7 monitoring of liquids and slurries in storage and process vessels including high temperature and pressure, up to a range of 20 m (66 ft) (Antenna dependant). Ideal for Hygienic applications including small vessels and low dielectric media. Click on the for the online configuration in the PIA Life Cycle Portal. Hygienic/Sanitary Approvals EHEDG EL Class I1) 1 EHEDG EL Aseptic Class I 1) 2 3-A (Tuchenhagen connections only - FC... FF) 2)3) 3 EHEDG EL Class I & 3-A (excludes Tuchenhagen connections) 2)) Process Connection Types (all types have TFM1600 PTFE lens) 316L st/st [1.35 or 1.0] 2" Sanitary Clamp according to ISO ) AA 3" Sanitary Clamp according to ISO 2852 AB " Sanitary Clamp according to ISO 2852 AC 316L st/st (1.35 or 1.0) & 30L st/st (1.301) DN 50 Aseptic/Hygienic nozzle/ slotted nut BA (instrument side) to DIN [Form A] 5) DN 80 Aseptic/Hygienic nozzle/ slotted nut BB (instrument side) to DIN [Form A] DN 100 Aseptic/Hygienic nozzle/ slotted nut BC (instrument side) to DIN [Form A] 316L st/st [1.35 or 1.0] DN 50 Aseptic/Hygienic flanged to DIN CA [Form A] 5) DN 80 Aseptic/Hygienic flanged to DIN CB [Form A] DN 100 Aseptic/Hygienic flanged to DIN CC [Form A] 316L st/st [1.35 or 1.0] DN 50 Aseptic/Hygienic Clamp according to DA DIN [Form A] 5) DN 80 Aseptic/Hygienic Clamp according to DB DIN [Form A] DN 100 Aseptic/Hygienic Clamp according to DC DIN [Form A] 316L st/st (1.35 or 1.0) & 30L st/st (1.301) DN 50 Hygienic nozzle/ slotted nut EA (instrument side) to DIN ) DN 80 Hygienic nozzle/ slotted nut EB (instrument side) to DIN DN 100 Hygienic nozzle/ slotted nut EC (instrument side) to DIN L st/st [1.35 or 1.0] Type F (50 mm) Tuchenhagen Varivent FA (EHEDG only) 5) Type N (68 mm) Tuchenhagen Varivent FB (EHEDG only) 5) Type F (50 mm) Tuchenhagen Varivent FC [3-A only & EPDM process seal C ( F )] 5) Type N (68 mm) Tuchenhagen Varivent FD [3-A only & EPDM process seal C ( F)] 5) Type F (50 mm) Tuchenhagen Varivent FE [3-A only & FKM process seal C ( F)] 5) Type N (68 mm) Tuchenhagen Varivent FF [3-A only & FKM process seal C ( F)] 5) EXCLUDE Process Connection - Electronics Head assembly spare only (select all other options as normal) YY /26 Siemens FI 01 June 2015 SITRANS LR250 hygienic encapsulated antenna 2-wire, 25 Ghz pulse radar level transmitter for continuous 7ML A 7 7 monitoring of liquids and slurries in storage and process vessels including high temperature and pressure, up to a range of 20 m (66 ft) (Antenna dependant). Ideal for Hygienic applications including small vessels and low dielectric media. Communication PROFIBUS PA ma HART, start-up at < 3.6 ma 2 FOUNDATION Fieldbus 3 Enclosure (with Cable Inlets) Aluminum, Epoxy paint, 2 X ½" NPT 0 Aluminum, Epoxy paint, 2 X M20 x Approvals General Purpose, CE, CSA, FM, FCC, R&TTE, RCM A Intrinsically Safe: CSA/FM Class I, Div. 1, Groups A, B, C, D, Class II, Div. 1, Groups E, F, G, Class III T FCC, Industry Canada B Intrinsically Safe: IECEx/ATEX II 1 GD Ex ia IIC T C Ga, Ex ia ta IIIC T100 C Da, INMETRO Ex ia IIC T Ga, Ex ia ta IIIC T100 C Da, CE, R&TTE, RCM Non-incendive: CSA/FM Class I, Div. 2, D Groups A, B, C, D T5, FCC, Industry Canada Non Sparking: ATEX II 3G Ex na IIC T Gc, CE, E R&TTE, RCM Increased Safety: IECEx/ATEX II 1/2 GD, 1D, 2D Ex e mb ia IIC T Ga/Gb, Ex ia ta IIIC T100 C Da, INMETRO Ex e ia mb IIC T Ga/Gb, Ex ia ta IIIC T100 C Da, CE, R&TTE, RCM 6) F Flameproof: IECEx/ATEX II 1/2 GD 1D, 2D Ex d mb G ia IIC T Ga/Gb, Ex ia ta IIIC T100 C Da, INMETRO Ex d ia mb IIC T Ga/Gb, Ex ia ta IIIC T100 C Da, CE, R&TTE, RCM 6) Explosion proof: CSA/FM Class I, II and III, Div. 1, Groups A, B, C, D, E, F, G, FCC, Industry Canada 6) H Non Sparking: NEPSI Ex na IIC T Gc K Intrinsically Safe: NEPSI Ex ia IIC T Ga, Ex iad 20 L T90 IP67 DIP A20 TA 90 ºC Flameproof: NEPSI Ex d ia mb IIC T Ga/Gb, M Ex iad 20 T90 IP67 DIP A20 TA 90 ºC 6) Increased Safety: NEPSI Ex e ia mb IIC T Ga/Gb, N Ex iad 20 T90 IP67 DIP A20 TA 90 ºC 6) Pressure Rating Rating per pressure/temperature curves in instruction 0 manual We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 9/5 in the appendix.

247 Continuous level measurement - Radar transmitters SITRANS LR250 Hygienic Encapsulated Antenna Order code Further designs Please add "-Z" to and specify Order code(s). Electrical Connection cable entry: Plug M12 (IP 67 rating) with mating connector 2)7)8) A50 Plug 7/8" (IP 67 rating) with mating Connector 2)8)9) A55 Test Certificates Manufacturer's Test Certificate M to DIN 55350, C11 Part 18 and to ISO 9000 Inspection Certificate 3.1 of EN 1020 C12 Functional Safety Functional Safety (SIL 2). Device suitable for use in C20 accordance with IEC and IEC )10) Namur Namur NE3 compliant, device preset to failsafe N07 < 3.6 ma 6) Tagging Stainless steel tag [69 mm x 50 mm (2.71x1.97inch)] Measuring-point number / identification Y15 (max. 27 characters) specify in plain text Operating Instructions for HART/mA device English A5E German A5E French A5E Note: The Operating Instructions should be ordered as a separate line item on the order. Compact Operating Instructions for HART/mA device English, French, German, Spanish, Italian, Dutch, A5E Danish, Finnish, Greek, Portuguese (Portugal), Swedish English, Bulgarian, Czech, Estonian, Hungarian, A5E Latvian, Lithuanian, Polish, Romanian, Slovakian, Slovenian English, Portuguese (Brazil), Chinese A5E This device is shipped with the Siemens Milltronics manual DVD containing the ATEX Compact Operating Instructions and Operating Instructions library. Operating Instructions for PROFIBUS PA device English A5E German A5E French A5E Note: The Operating Instructions should be ordered as a separate line item on the order. Compact Operating Instructions for PROFIBUS PA device English, French, German, Spanish, Italian, Dutch, A5E Danish, Finnish, Greek, Portuguese (Portugal), Swedish English, Bulgarian, Czech, Estonian, Hungarian, A5E Latvian, Lithuanian, Polish, Romanian, Slovakian, Slovenian English, Portuguese (Brazil), Chinese A5E30662 This device is shipped with the Siemens Milltronics manual DVD containing the ATEX Compact Operating Instructions and Operating Instructions library. Operating Instructions for FOUNDATION Fieldbus device English German French Note: The Operating Instructions should be ordered as a separate line item on the order. Compact Operating Instructions for FOUNDATION Fieldbus device English, French, German, Spanish, Italian, Dutch, Danish, Finnish, Greek, Portuguese (Portugal), Swedish English, Bulgarian, Czech, Estonian, Hungarian, Latvian, Lithuanian, Polish, Romanian, Slovakian, Slovenian English, Portuguese (Brazil), Chinese This device is shipped with the Siemens Milltronics manual DVD containing the ATEX Compact Operating Instructions and Operating Instructions library. Accessories Handheld programmer, Intrinsically safe, EEx ia (LUI enabled) HART modem/usb (for use with a PC and SIMATIC PDM) One metallic cable gland M20x1.5, rated C ( F), HART (two are required) 6) One metallic cable gland M20x1.5, rated C ( F), PROFIBUS PA and FOUNDATION Fieldbus (two are required) 8) SITRANS RD100, loop powered display - see Chapter 7 SITRANS RD200, universal input display with Modbus conversion - see Chapter 7 SITRANS RD300, dual line display with totalizer and linearization curve and Modbus conversion - see Chapter 7 SITRANS RD500 web, universal remote monitoring solution for instrumentation - see Chapter 7 For applicable back up point level switch - see point level measurement section A5E A5E A5E A5E A5E A5E ML1930-1BK 7MF997-1DB 7ML1930-1AP 7ML1930-1AQ 7ML ML ML ML We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 9/5 in the appendix. 1) Available with process connection options AA... FB & YY only 2) Available with Approval options A, B, C, L only 3) Available with Process connection FC... FF only ) Available with process connection options AA... EC & YY only 5) Max. range 10 m (32.8 ft), dk > 3 [20 m (66 ft) and dk > 1.6 if installed in a stillpipe] 6) Applicable with Communication option 2 only 7) Available with Enclosure option 1 only 8) Available with Communication options 1 and 3 only. 9) Available with Enclosure option 0 only 10) Available with Approval options A, B, C, D, E, K, L only Siemens FI 01 June 2015 /27

248 Continuous level measurement - Radar transmitters SITRANS LR250 Hygienic Encapsulated Antenna Characteristic curves DIN Sanitary/Hygienic nozzle/slotted nut: DN 50, DN 80, and DN 100 DIN Aseptic/Hygienic nozzle/slotted nut: DN 50, DN 80, and DN 100 P 30 bar (35 psi) 20 bar (290 psi) -1 bar (-1.5 psi) 1 Atmospheric P Allowable operating pressures T Allowable operating temperatures 1 10 bar (15 psi) -0 F 1 F (-0 C) (-10 C) -50 C (-58 F) 0 C 100 F (38 C) RT 50 C (122 F) 200 F (93 C) 100 C (212 F) 300 F (19 C) 150 C (302 F) (32 F) -29 C 170 C (-20 F) (338 F) 00 F (20 C) 200 C (392 F) T SITRANS LR250 Hygienic Encapsulated Antenna, pressure/temperature curves DIN Aseptic/Hygienic flanged: DN 50, DN 80, and DN 100 P 30 bar (35 psi) 20 bar (290 psi) 1-1 bar (-1.5 psi) Atmospheric 1 10 bar (15 psi) P Allowable operating pressures T Allowable operating temperatures -0 F 1 F (-0 C) (-10 C) -50 C (-58 F) -29 C (-20 F) 0 C (32 F) 100 F (38 C) RT 50 C (122 F) 200 F (93 C) 100 C (212 F) 300 F (19 C) 00 F (20 C) 150 C 200 C (302 F) (392 F) 170 C (338 F) Note: For pressure applications, all attachment hardware must be suitably rated. T SITRANS LR250, Hygienic Encapsulated Antenna, pressure/temperature curves /28 Siemens FI 01 June 2015

249 Continuous level measurement - Radar transmitters SITRANS LR250 Hygienic Encapsulated Antenna DIN Aseptic/Hygienic clamp: DN 50, DN 80, and DN 100 IS Sanitary/Hygienic clamp: 2", 3", and " Tuchenhagen Varivent face seal clamp: Type N (68 mm) and Type F (50 mm) P 30 bar (35 psi) 20 bar (290 psi) 10 bar (15 psi) -1 bar (-1.5 psi) 1 Atmospheric P Allowable operating pressures T Allowable operating temperatures SITRANS LR250 Hygienic Encapsulated Antenna, pressure/temperature curves 1-0 F 1 F (-0 C) (-10 C) -50 C (-58 F) 0 C 100 F (38 C) RT 50 C (122 F) 200 F (93 C) 100 C (212 F) 300 F (19 C) 150 C (302 F) (32 F) -29 C 170 C (-20 F) (338 F) 00 F (20 C) 200 C (392 F) Note: For pressure applications, all clamps must be rated accordingly. T Siemens FI 01 June 2015 /29

250 Continuous level measurement - Radar transmitters SITRANS LR250 Hygienic Encapsulated Antenna Dimensional drawings Hygienic encapsulated antenna (2" ISO 2852 sanitary clamp) 50.0 (2.00) 1/2" NPT cable entry (or alternatively, M20 cable gland) Threaded cover (6.02) (6.57) 90.0 (3.5) Enclosure (7.01) Retaining collar 27.2 (10.80) (8.89) Process connection Sensor reference point Ø.0 (1.73) Ø6.0 (2.52) 11.0 (0.3) SITRANS LR250 Hygienic Encapsulated Antenna, dimensions in mm (inch) /250 Siemens FI 01 June 2015

251 Continuous level measurement - Radar transmitters SITRANS LR250 Hygienic Encapsulated Antenna Hygienic encapsulated antenna (3" ISO 2852 sanitary clamp) 50.0 (2.00) 1/2" NPT cable entry (or alternatively, M20 cable gland) Threaded cover (6.57) (6.02) 90.0 (3.5) Enclosure (7.01) Retaining collar 33.2 (13.51) (11.6) Process connection Sensor reference point Ø7.7 (2.9) Ø91.0 (3.58) 1.5 (0.57) SITRANS LR250 Hygienic Encapsulated Antenna, dimensions in mm (inch) Siemens FI 01 June 2015 /251

252 Continuous level measurement - Radar transmitters SITRANS LR250 Hygienic Encapsulated Antenna Hygienic encapsulated antenna (" ISO 2852 sanitary clamp) 50.0 (2.00) 1/2" NPT cable entry (or alternatively, M20 cable gland) Threaded cover (6.02) (6.57) 90.0 (3.5) Enclosure (7.01) Retaining collar 33.2 (13.51) (11.6) Process connection Sensor reference point Ø7.7 (2.9) Ø119.0 (.69) 1.5 (0.57) SITRANS LR250 Hygienic Encapsulated Antenna, dimensions in mm (inch) /252 Siemens FI 01 June 2015

253 Continuous level measurement - Radar transmitters SITRANS LR250 Hygienic Encapsulated Antenna Hygienic encapsulated antenna (DN 50 nozzle/slotted nut to DIN 11851) 50.0 (2.00) 1/2" NPT cable entry (or alternatively, M20 cable gland) Threaded cover (6.02) (6.57) 90.0 (3.5) Enclosure (7.01) Retaining collar Threaded nut 27.2 (10.80) (8.89) Sensor reference point Ø.0 (1.73) Ø57.6 (2.27) Ø63.7 (2.51) 11.0 (0.3) Note: Cut out of process connection and placement of threaded nut are shown for illustration purposes only. SITRANS LR250 Hygienic Encapsulated Antenna, dimensions in mm (inch) Siemens FI 01 June 2015 /253

254 Continuous level measurement - Radar transmitters SITRANS LR250 Hygienic Encapsulated Antenna Hygienic encapsulated antenna (DN 80 nozzle/slotted nut to DIN 11851) 50.0 (2.00) 1/2" NPT cable entry (or alternatively, M20 cable gland) Threaded cover (6.02) (6.57) 90.0 (3.5) Enclosure (7.01) Retaining collar Threaded nut (11.6) 33.2 (13.51) Sensor reference point Ø7.7 (2.9) Ø88.6 (3.9) Ø9.7 (3.73) 1.5 (0.57) Note: Cut out of process connection and placement of threaded nut are shown for illustration purposes only. SITRANS LR250 Hygienic Encapsulated Antenna, dimensions in mm (inch) /25 Siemens FI 01 June 2015

255 Continuous level measurement - Radar transmitters SITRANS LR250 Hygienic Encapsulated Antenna Hygienic encapsulated antenna (DN 100 nozzle/slotted nut to DIN 11851) 50.0 (2.00) 1/2" NPT cable entry (or alternatively, M20 cable gland) Threaded cover (6.57) (6.02) 90.0 (3.5) Enclosure (7.01) Retaining collar Threaded nut (11.6) 33.2 (13.51) Sensor reference point Ø7.7 (2.9) Ø107.6 (.2) Ø113.7 (.8) 1.5 (0.57) Note: Cut out of process connection and placement of threaded nut are shown for illustration purposes only. SITRANS LR250 Hygienic Encapsulated Antenna, dimensions in mm (inch) Siemens FI 01 June 2015 /255

256 Continuous level measurement - Radar transmitters SITRANS LR250 Hygienic Encapsulated Antenna Hygienic encapsulated antenna (DN 50 aseptic clamp to DIN ) 50.0 (2.00) 1/2" NPT cable entry (or alternatively, M20 cable gland) Threaded cover (6.02) (6.57) 90.0 (3.5) (7.01) Enclosure Retaining collar Threaded nut 27.2 (10.80) (8.89) Sensor reference point Ø.0 (1.73) Ø66.9 (2.63) Ø72.0 (2.83) 11.0 (0.3) Note: Cut out of process connection and placement of threaded nut are shown for illustration purposes only. SITRANS LR250 Hygienic Encapsulated Antenna, dimensions in mm (inch) /256 Siemens FI 01 June 2015

257 Continuous level measurement - Radar transmitters SITRANS LR250 Hygienic Encapsulated Antenna Hygienic encapsulated antenna (DN 80 aseptic clamp to DIN ) 50.0 (2.00) 1/2" NPT cable entry (or alternatively, M20 cable gland) Threaded cover (6.57) (6.02) 90.0 (3.5) Enclosure (7.01) Retaining collar Threaded nut (11.7) 33. (13.52) Sensor reference point Ø7.7 (2.9) Ø98.9 (3.89) Ø10.0 (.09) 1.5 (0.57) Note: Cut out of process connection and placement of threaded nut are shown for illustration purposes only. SITRANS LR250 Hygienic Encapsulated Antenna, dimensions in mm (inch) Siemens FI 01 June 2015 /257

258 Continuous level measurement - Radar transmitters SITRANS LR250 Hygienic Encapsulated Antenna Hygienic encapsulated antenna (DN 100 aseptic clamp to DIN ) 50.0 (2.00) 1/2" NPT cable entry (or alternatively, M20 cable gland) Threaded cover (6.57) (6.02) 90.0 (3.5) Enclosure (7.01) Retaining collar Threaded nut (11.7) 33. (13.52) Sensor reference point Ø7.7 (2.9) Ø118.9 (.68) Ø12.0 (.88) 1.5 (0.57) Note: Cut out of process connection and placement of threaded nut are shown for illustration purposes only. SITRANS LR250 Hygienic Encapsulated Antenna, dimensions in mm (inch) /258 Siemens FI 01 June 2015

259 Continuous level measurement - Radar transmitters SITRANS LR250 Hygienic Encapsulated Antenna Hygienic encapsulated antenna (DN 50 aseptic flange to DIN ) 50.0 (2.00) 1/2" NPT cable entry (or alternatively, M20 cable gland) Threaded cover (6.57) (6.02) 90.0 (3.5) Enclosure (7.01) Retaining collar (8.89) 27.2 (10.80) Flange Sensor reference point Ø.0 (1.73) Ø63.0 (2.8) Ø9.5 (3.72) 11.0 (0.3) Note: Cut out of process connection and flange are shown for illustration purposes only. SITRANS LR250 Hygienic Encapsulated Antenna, dimensions in mm (inch) Siemens FI 01 June 2015 /259

260 Continuous level measurement - Radar transmitters SITRANS LR250 Hygienic Encapsulated Antenna Hygienic encapsulated antenna (DN 80 aseptic flange to DIN ) 50.0 (2.00) 1/2" NPT cable entry (or alternatively, M20 cable gland) Threaded cover (6.02) (6.57) 90.0 (3.5) Enclosure (7.01) Retaining collar 33.2 (13.51) (11.6) Flange Sensor reference point Ø7.7 (2.9) Ø9.5 (3.72) Ø133.0 (5.2) 1.5 (0.57) Note: Cut out of process connection and flange are shown for illustration purposes only. SITRANS LR250 Hygienic Encapsulated Antenna, dimensions in mm (inch) /260 Siemens FI 01 June 2015

261 Continuous level measurement - Radar transmitters SITRANS LR250 Hygienic Encapsulated Antenna Hygienic encapsulated antenna (DN 100 aseptic flange to DIN ) 50.0 (2.00) 1/2" NPT cable entry (or alternatively, M20 cable gland) Threaded cover (6.02) (6.57) 90.0 (3.5) Enclosure (7.01) Retaining collar 33.2 (13.51) (11.6) Flange Sensor reference point Ø7.7 (2.9) Ø113.5 (.7) Ø159.0 (6.26) 1.5 (0.57) Note: The cut out of the process connection and the flange are shown for illustration purposes only. SITRANS LR250 Hygienic Encapsulated Antenna, dimensions in mm (inch) Siemens FI 01 June 2015 /261

262 Continuous level measurement - Radar transmitters SITRANS LR250 Hygienic Encapsulated Antenna Hygienic encapsulated antenna (DN 50 aseptic clamp to DIN ) 50.0 (2.00) 1/2" NPT cable entry (or alternatively, M20 cable gland) Threaded cover (6.02) (6.57) 90.0 (3.5) Enclosure (7.01) Retaining collar (10.78) (8.87) Process connection Sensor reference point Ø.0 (1.73) Ø63.0 (2.8) Ø77.5 (3.05) 11.0 (0.3) Note: Cut out of process connection is shown for illustration purposes only. SITRANS LR250 Hygienic Encapsulated Antenna, dimensions in mm (inch) /262 Siemens FI 01 June 2015

263 Continuous level measurement - Radar transmitters SITRANS LR250 Hygienic Encapsulated Antenna Hygienic encapsulated antenna (DN 80 aseptic clamp to DIN ) 50.0 (2.00) 1/2" NPT cable entry (or alternatively, M20 cable gland) Threaded cover (6.02) (6.57) 90.0 (3.5) Enclosure (7.01) Retaining collar 33.2 (13.51) (11.6) Process connection Sensor reference point Ø7.7 (2,9) Ø9.5 (3.72) Ø106.0 (.17) 1.5 (0.57) Note: Cut out of process connection is shown for illustration purposes only. SITRANS LR250 Hygienic Encapsulated Antenna, dimensions in mm (inch) Siemens FI 01 June 2015 /263

264 Continuous level measurement - Radar transmitters SITRANS LR250 Hygienic Encapsulated Antenna Hygienic encapsulated antenna (DN 100 aseptic clamp to DIN ) 50.0 (2.00) 1/2" NPT cable entry (or alternatively, M20 cable gland) Threaded cover (6.02) (6.57) 90.0 (3.5) Enclosure (7.01) Retaining collar (11.6) 33.2 (13.51) Process connection Sensor reference point Ø7.7 (2.9) Ø113.5 (.7) Ø130.0 (5.12) 1.5 (0.57) Note: Cut out of process connection is shown for illustration purposes only. SITRANS LR250 Hygienic Encapsulated Antenna, dimensions in mm (inch) /26 Siemens FI 01 June 2015

265 Continuous level measurement - Radar transmitters SITRANS LR250 Hygienic Encapsulated Antenna Hygienic encapsulated antenna (Tuchenhagen Type F, 50 mm) 50.0 (2.00) 1/2" NPT cable entry (or alternatively, M20 cable gland) Threaded cover (6.02) (6.57) 90.0 (3.5) Enclosure (7.01) Retaining collar (9.16) (10.89) Process connection Sensor reference point Ø50.0 (2.00) Ø66.0 (2.60) 6.5 (0.26) SITRANS LR250 Hygienic Encapsulated Antenna, dimensions in mm (inch) Siemens FI 01 June 2015 /265

266 Continuous level measurement - Radar transmitters SITRANS LR250 Hygienic Encapsulated Antenna Hygienic encapsulated antenna (Tuchenhagen Type N, 68 mm) 50.0 (2.00) 1/2" NPT cable entry (or alternatively, M20 cable gland) Threaded cover (6.02) (6.57) 90.0 (3.5) Enclosure (7.01) Retaining collar 27.2 (10.80) (8.88) Process connection Sensor reference point Ø 68.0 (2.68) Ø8.0 (3.31) 11.2 (0.) SITRANS LR250 Hygienic Encapsulated Antenna, dimensions in mm (inch) /266 Siemens FI 01 June 2015

267 Continuous level measurement - Radar transmitters SITRANS LR250 Hygienic Encapsulated Antenna Schematics Connect the wires to the terminals as shown: the polarity is identified on the terminal block. Hand Programmer Shield for HART, PROFIBUS PA, and Part number: Gland FOUNDATION Fieldbus 7ML1930-1BK Intrinsically Safe versions only. Notes: 1. DC terminal shall be supplied from a source providing electrical isolation between the input and output, to meet the applicable safety requirements of IEC All field wiring must have insulation suitable for rated input voltages. 3. Use shielded twisted pair cable ( AWG) for HART version.. Separate cables and conduit may be required to conform to standard instrumentation wiring practices or electrical codes. SITRANS LR250 connections Siemens FI 01 June 2015 /267

268 Continuous level measurement - Radar transmitters SITRANS LR250 Hygienic Encapsulated Specials Selection and ordering data SITRANS LR250 hygienic encapsulated Specials For "Electronics Head only" follow the standard configuration and choose YY option on positions 9 and 10 of the full part number. For example: 7ML533-1YY20-1AA0 will order an electronics head for the following: EHEDG EL Class 1 approval,... 20mA HART, M20 cable entries, General purpose Haz Loc approval, pressure rating as per manual. Spare Lens Kits (Lens and O-ring) Kit, 2 inch, ISO2852, HEA, Lens, silicone secondary O-ring Kit, 3 inch, ISO2852, HEA, Lens, silicone secondary O-ring Kit, inch, ISO2852, HEA, Lens, silicone secondary O-ring Kit, DN 50, DIN11851, HEA, Lens, silicone secondary O-ring Kit, DN 80, DIN11851, HEA, Lens, silicone secondary O-ring Kit, DN 100, DIN11851, HEA, Lens, silicone secondary O-ring Kit, DN 50, DIN1186-1, HEA, Lens, silicone secondary O-ring Kit, DN 80, DIN1186-1, HEA, Lens, silicone secondary O-ring Kit, DN 100, DIN1186-1, HEA, Lens, silicone secondary O-ring Kit, DN 50, DIN1186-2/3, HEA, Lens, silicone secondary O-ring Kit, DN 80, DIN1186-2/3, HEA, Lens, silicone secondary O-ring Kit, DN 100, DIN1186-2/3, HEA, Lens, silicone secondary O-ring Kit, Tuchenhagen, Type F, HEA, Lens, silicone secondary O-ring Kit, Tuchenhagen, Type N, HEA, Lens, silicone secondary O-ring Accessories (customer side process connection and FKM and EPDM seal for each size and type) Kit DN 50 DIN GS Form A tank connection, EPDM Seal Class II Kit, DN 80 DIN GS Form A tank connection, EPDM Seal Class II Kit, DN 100 DIN GS Form A tank connection, EPDM Seal Class II A5E A5E A5E A5E A5E A5E A5E A5E A5E A5E A5E A5E A5E A5E A5E A5E A5E SITRANS LR250 hygienic encapsulated Specials Kit DN 50 DIN GS Form A tank A5E connection, FKM Seal Class I Kit, DN 80 DIN GS Form A tank A5E connection, FKM Seal Class I Kit, DN 100 DIN GS Form A tank A5E connection, FKM Seal Class I Kit 2" ISO 2852 tank connection, Clamp, A5E Cleanable EPDM Seal Class II Kit 3" ISO 2852 tank connection, Clamp, A5E Cleanable EPDM Seal Class II Kit " ISO 2852 tank connection, Clamp, A5E Cleanable EPDM Seal Class II Kit DN 50 DIN SC tank connection, A5E EPDM Seal Class II 11) Kit DN 80 DIN SC tank connection, A5E EPDM Seal Class II 11) Kit DN 100 DIN SC tank connection, A5E EPDM Seal Class II 11) Kit DN 50 DIN SC tank connection, A5E FKM Seal Class II Kit DN 80 DIN SC tank connection, A5E FKM Seal Class II Kit DN 100 DIN SC tank connection, A5E FKM Seal Class II Kit DN 50 DIN Form A tank A5E connection, M8 Hardware (nut/bolt/washer), EPDM Seal Class II Kit DN 80 DIN Form A tank A5E connection, M10 Hardware (nut/bolt/washer), EPDM Seal Class II Kit DN 100 DIN Form A tank A5E connection, M10 Hardware (nut/bolt/washer), EPDM Seal Class II Kit DN 50 DIN Form A tank A5E connection, M8 Hardware (nut/bolt/washer), FKM Seal Class I Kit DN 80 DIN Form A tank A5E connection, M10 Hardware (nut/bolt/washer), FKM Seal Class I Kit DN 100 DIN Form A tank A5E connection, M10 Hardware (nut/bolt/washer), FKM Seal Class I Kit DN 50 DIN Form A tank A5E connection, Clamp, EPDM Seal Class II Kit DN 80 DIN Form A tank A5E connection, Clamp, EPDM Seal Class II Kit DN 100 DIN Form A tank A5E connection, Clamp, EPDM Seal Class II Kit DN 50 DIN Form A tank A5E connection, Clamp, FKM Seal Class I Kit DN 80 DIN Form A tank A5E connection, Clamp, FKM Seal Class I Kit DN 100 DIN Form A tank A5E connection, Clamp, FKM Seal Class I Kit Type F, Tuchenhagen, Clamp, EPDM Seal A5E Class II (EHEDG only) - no tank connection Kit Type N, Tuchenhagen, Clamp, EPDM Seal A5E Class II (EHEDG only) - no tank connection Kit Type F, Tuchenhagen, Clamp, FKM Seal A5E Class I (EHEDG only) - no tank connection Kit Type N, Tuchenhagen, Clamp, FKM Seal A5E Class I (EHEDG only) - no tank connection 11) Class II for low fat applications when EPMD seal used on DIN /268 Siemens FI 01 June 2015

269 Continuous level measurement - Radar transmitters SITRANS LR260 Overview Configuration Mounting on a nozzle Min. clearance: 10 (0.) Installation Min (39) SITRANS LR260 is a 2-wire 25 GHz pulse radar level transmitter for continuous monitoring of solids and liquids in storage vessels including extreme levels of dust and high temperatures, to a range of 30 m (98. ft). Benefits Graphical local user interface (LUI) makes operation simple with plug-and-play setup using the intuitive Quick Start Wizard LUI displays echo profiles for diagnostic support 25 GHz high frequency allows for small horn antennas mounted easily in nozzles Communication using HART or PROFIBUS PA Process Intelligence signal processing for improved measurement reliability and Auto False-Echo Suppression of fixed obstructions Programming using infrared Intrinsically Safe handheld programmer or SIMATIC PDM Emission cone Beam angle: 2" horn = 15 3" horn = 10 " horn = 8 Application SITRANS LR260 includes a graphical local user interface (LUI) that improves setup and operation using an intuitive Quick Start Wizard, and echo profile displays for diagnostic support. Startup is easy using the Quick Start wizard with a few parameters required for basic operation. SITRANS LR260 s unique design allows safe and simple programming using the Intrinsically Safe handheld programmer without having to open the instrument s lid. SITRANS LR260 measures virtually any solids material to a range of 30 m (98. ft). Key Applications: cement powder, plastic powder/pellets, grain, flour, coal, solids and liquids bulk storage vessels, and other applications. Positioning with easy Aimer SITRANS LR260 installation, dimensions in mm (inch) Siemens FI 01 June 2015 /269

270 Continuous level measurement - Radar transmitters SITRANS LR260 Technical specifications Mode of operation Measuring principle Frequency Minimum detectable distance Maximum measuring range 1) Solids Liquids Output - HART Power Fail signal Load Pulse radar level measurement K-band (25.0 GHz) 0.05 m (2 inch) from end of horn 2" horn: 10 m (32.8 ft) 3" horn: 20 m (65.6 ft) " horn: 30 m (98. ft) 2" horn: 20 m (65.6 ft) 3" horn: 30 m (98. ft) " horn: 30 m (98. ft) ma (± 0.02 ma accuracy) Nominal 2 V DC (max. 30 V DC) 3.6 ma ma; or last value Ω Output - PROFIBUS PA Per IEC ma Profile version 3.01, Class B Performance (according to reference conditions IEC ) Maximum measured error (including hysteresis and non-repeatability) 25 mm (1 inch) from minimum detectable distance to 300 mm (11.8 inch) Remainder of range = 10 mm (0.39 inch) or 0.1 % of spa (whichever is greater) Rated operating conditions Installation conditions Location Indoor/outdoor Ambient conditions (enclosure) Ambient temperature C ( F) Installation category I Pollution degree Medium conditions Dielectric constant ε r ε r > 1.6, antenna and application dependent Process temperature C ( F) Process pressure 0.5 bar g (7.25 psi g) maximum 3 bar g (3.5 psi g) optional with 80 C (176 F) temperature max Design Enclosure Construction Aluminum, polyester powder-coated Conduit entry 2 x M20x1.5 or 2 x ½" NPT Degree of protection Type X/NEMA X, Type 6/ NEMA 6, IP67, IP68 Weight < 8.1 kg (17.9 lb) including " flange and standard Easy Aimer with " horn antenna Display (local) Graphic LCD, with bar graph representing level Flange and horn (easy aimer model) Material 30 stainless steel Horn antenna 2" horn 3" horn " horn Process connections Universal flanges 2) Mechanical (Threaded Connection model) Threaded connection Materials Certificates and approvals General Radio 2 inch/50 mm, 3 inch/80 mm, inch/100 mm, 6 inch/150 mm 2" NPT (ASME B1.20.1), R (BSPT, EN ) or G (BSPP, EN ISO 228-1) 316L/1.0 or 316L/1.35 stainless steel PTFE emitter CSA US/C, CE, FM Europe (R&TTE), FCC, Industry Canada, RCM Hazardous CSA/FM Class II, Div. 1, Groups E, F, G, Class III ATEX II 1D, 1/2D, 2D Ex ta IIIC T100 ºC Da IECEx/ATEX II 1 GD Ex ia IIC T Ga, Ex ta IIIC T100 ºC Da CSA/FM Class I, II, III, Div. 1, Groups A, B, C, D, E, F, G SABS ARP0108 Ex ia IIC T Ga Programming Intrinsically Safe Siemens handheld Infrared receiver programmer Approvals for handheld programmer IS model: ATEX II 1GD Ex ia IIC T Ga Ex iad 20 T135 C Ta = C CSA/FM Class I, II, and III, Div. 1, Groups A,B,C,D,E,F,G, T6 Ta = 50 C Handheld communicator HART communicator 375 PC SIMATIC PDM Display (local) Graphic local user interface including quick start wizard and echo profile displays 1) From sensor reference point 2) Universal flange mates with EN (PN 16)/ASME B16.5 (150 lb)/ JIS 2220 (10K) bolt hole pattern /270 Siemens FI 01 June 2015

271 Continuous level measurement - Radar transmitters SITRANS LR260 SITRANS LR260 2-wire, 25 GHz pulse radar level transmitter for continuous monitoring of solids to a range of 30 m (98. ft). Order handheld programmer separately Click on the for the online configuration in the PIA Life Cycle Portal. Process connection Universal flat faced flange fits ANSI/DIN/JIS flanges, Easy Aimer with integral (Easy Aimer ball) 2 inch/50 mm A 3 inch/80 mm B inch/100 mm C 6 inch/150 mm D Threaded connection 2" NPT (ASME B1.20.1) (tapered thread) 1)2)5) E R 2" [(BSPT), EN ] (tapered thread) 1)2)5) F G 2" [(BSPT), EN ISO 228-1] (parallel thread) 1)2)5) G Antenna 2" Horn antenna, fits 50 mm or 2" nozzles 1) A 2" Horn antenna with 100 mm extension 1) B 2" Horn antenna with 200 mm extension 1) C 2" Horn antenna with 500 mm extension 1)2) D 2" Horn antenna with mm extension 1)2) E 3" Horn antenna, fits 80 mm or 3" nozzles 3) F 7ML527-3" Horn antenna with 100 mm extension 3) G 3" Horn antenna with 200 mm extension 3) H 3" Horn antenna with 500 mm extension 2)3) J 3" Horn antenna with mm extension 2)3) K " Horn antenna, fits 100 mm or " nozzles L " Horn antenna with 100 mm extension M " Horn antenna with 200 mm extension N " Horn antenna with 500 mm extension 2) P " Horn antenna with mm extension 2) Q Purge (self cleaning) connection No purge connection 0 Purge connection Output/communication ma, HART 0 PROFIBUS PA 1 Cable inlet 2 x M20x1.5 A 2 x ½" NPT B Note: Polymeric cable glands will be provided with M20 devices. Approvals General purpose, CSA US/C, FM, Industry Canada, FCC, CE, R&TTE, RCM CSA/FM Class II, Div. 1, Groups E, F, G, Class III, Industry Canada, FCC, RCM ATEX II 1D, 1/2D, 2D Ex ta IIIC T100 ºC Da, CE, R&TTE, RCM, INMETRO Non-incendive, CSA/FM Class I, Div. 2, Groups A, B, C, D, Industry Canada, FCC, RCM Intrinsically safe, IECEx/ATEX II 1 GD Ex ia IIC T Ga, Ex ta IIIC T100 ºC Da, R&TTE, RCM Intrinsically safe, CSA/FM Class I, II, III, Div. 1, Groups A, B, C, D, E, F, G, Industry Canada, FCC, RCM Intrinsically safe, South Africa ARP0108 Ex ia IIC T Ga Pressure rating Rating per Pressure/Temperature curves in manual 6) bar g (7.25 psi g) maximum 1 A B C D E F G Further designs Please add "-Z" to and specify Order code(s). Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Measuring-point number/identification (max. 27 characters); specify in plain text Manufacturer's test certificate: M to DIN 55350, Part 18 and to ISO 9000 Inspection Certificate Type 3.1 per EN 1020 ) Operating Instructions for HART/mA device English German Note: The Operating Instructions should be ordered as a separate line item on the order. Multi-language Quick Start manual This device is shipped with the Siemens Milltronics manual DVD containing the ATEX Quick Start and Operating Instructions library. Operating Instructions for PROFIBUS PA device English German Note: The Operating Instructions should be ordered as a separate line item on the order. Multi-language Quick Start manual This device is shipped with the Siemens Milltronics manual DVD containing the ATEX Quick Start and Operating Instructions library. Accessories One metallic cable gland M20x1.5, rated C ( F), HART One metallic cable gland M20x1.5, rated C ( F), PROFIBUS PA Handheld programmer, Infrared, Intrinsically Safe Dust cap, PTFE, for 2 inch/50 mm horn Dust cap, PTFE, for 3 inch/75 mm horn Dust cap, PTFE, for inch/100 mm horn HART modem/usb (for use with a PC and SIMATIC PDM) SITRANS RD100, loop powered display - see Chapter 7 SITRANS RD200, universal input display with Modbus conversion - see Chapter 7 SITRANS RD300, dual line display with totalizer and linearization curve and Modbus conversion - see Chapter 7 SITRANS RD500 web, universal remote monitoring solution for instrumentation - see Chapter 7 For applicable back up point level switch - see point level measurement section Note: Products shipped with plastic cable gland, rated to -20 C. If -0 C rating required, then metallic cable gland is recommended. 1) Maximum measurement range 10 m (32.8 ft) solids or 20 m (65.6 ft) liquids 2) Available with Purge option 0 only 3) Maximum measurement range 20 m (65.6 ft) solids or 30 m (98. ft) liquids ) Available with pressure option 0 only 5) Available with Antenna Options A, B, F, G, L, and M only 6) Available with pressure option 0 only Order code Y15 C11 C12 7ML1998-5KE03 A5E A5E ML1998-5KF03 A5E A5E ML1930-1AP 7ML1930-1AQ 7ML1930-1BK 7ML1930-1DE 7ML1930-1BL 7ML1930-1BM 7MF997-1DB 7ML ML ML ML Siemens FI 01 June 2015 /271

272 Continuous level measurement - Radar transmitters SITRANS LR260 Characteristic curves Maximum flange and process temperatures versus allowable ambient temperature Ambient temperature ( C) Process flange surface temperature ( C) SITRANS LR260 Ambient/Process Flange Surface Temperature Curve Dimensional drawings Nameplate Enclosure/electronics Optional purge connection with factory-installed 1/8" NPT plug 268 (10.6) Universal slotted flange Optional extension Process device tag Sensor reference point 100/200/500/1000 (3.93/7.87/19.68/39.37) Optional PTFE dust cap Horn 2" horn: 163 (6.) 3" horn: 228 (9.0) " horn: 285 (11.2) Clamp screw 9 (1.9) 7.5 (2.9) 97.5 (3.8) SITRANS LR260, dimensions in mm (inch) /272 Siemens FI 01 June 2015

273 Continuous level measurement - Radar transmitters SITRANS LR260 SITRANS LR (2.0) ½" NPT cable entry (or alternatively, M20 cable gland) Threaded cover 15 (6.1) 167 (6.6) 90 (3.5) 281 (11.1) 28 (1.1)* 196 (7.7) Optional 100 (3.93) Horn Extension Enclosure/ electronics Retaining collar Process device tag Horn 159 (6.26) Sensor reference point Horn O.D. Horn O.D. Antenna Type 2" horn 3" horn " horn Antenna O.D. 7.8 (1.88) 7.8 (2.9) 9.8 (3.73) 1-1/2" threaded connection N/A N/A N/A Height to sensor reference point 2" threaded connection 166 (6.55) 199 (7.85) 25 (10) 3" threaded connection 180 (7.09) 213 (8.39) 268 (10.55) Beam angle 15 degrees 10 degrees 8 degrees Measurement range 20 m (65.6 ft) 20 m (65.6 ft) 20 m (65.6 ft) SITRANS LR260, dimensions in mm (inch) Schematics Connect the wires to the terminals as shown: the polarity is identified on the terminal block. Hand programmer Gland Shield for HART and PROFIBUS PA intrinsically safe versions only. Part number: 7ML1930-1BK Notes: 1. DC terminal shall be supplied from a source providing electrical isolation between the input and output, to meet the applicable safety requirements of IEC All field wiring must have insulation suitable for rated input voltages. 3. Use shielded twisted pair cable ( AWG) for HART version.. Separate cables and conduit may be required to conform to standard instrumentation wiring practices or electrical codes. SITRANS LR260 connections Siemens FI 01 June 2015 /273

274 Continuous level measurement - Radar transmitters SITRANS LR60 Overview The SITRANS LR60 is a -wire, 2 GHz FMCW radar level transmitter with extremely high signal-to-noise ratio and advanced signal processing for continuous monitoring of solids up to 100 m (328 ft). It is ideal for measurement in extreme dust. Application SITRANS LR60 provides excellent results even during conditions of extreme dust. The integral Easy Aimer included on the SITRANS LR60 allows for easy positioning for optimum measurement on solids. Process Intelligence onboard SITRANS LR60 means advanced signal processing is harnessed for reliable operation on both simple and difficult solids application. SITRANS LR60 features a robust enclosure, flange and horn components. It is virtually unaffected by atmospheric or temperature conditions within the vessel. An optional dust cap is available for sticky solids. Optional air purging is also available for extremely sticky applications. Safe on-site local programming is simple using the Intrinsically Safe handheld programmer. SIMATIC PDM can be used for easy remote programming using HART or PROFIBUS PA. The characteristics of 2 GHz and high signal-to-noise ratio contribute to exceptional signal reflection, regardless of the dielectric value of the medium. Key Applications: long-range dusty applications, cement powder, fly-ash, coal, flour, grain, plastics Benefits Process Intelligence for advanced signal processing and quick and easy adjustment Self-guided quick start wizard for plug and play start-up 2 GHz provides superior reflective properties on solids surfaces 100 m (328 ft) range for long-range and difficult applications Easy Aimer optimizes signal quality on sloped surfaces Programming using infrared Intrinsically Safe handheld programmer or with SIMATIC PDM or HART handheld device Configuration Beam angle Mounting unit on vessel Installation in mounting nozzle Positioning with Easy Aimer 8 11 inch horn 3 inch horn 10 (0.39) Note: For best signal, always use largest horn size possible. SITRANS LR60 installation, dimensions in mm (inch) /27 Siemens FI 01 June 2015

275 Continuous level measurement - Radar transmitters SITRANS LR60 Technical specifications Mode of operation Measuring principle Frequency Measuring range Output FMCW radar level measurement GHz FMCW m ( ft) Analog output (HART) Signal range Optically isolated Load Max. 600 Ω Fail-safe ma signal programmable as high, low or hold (LOE) Communication HART, optional PROFIBUS PA Digital output Relay, NC or NO function, max. 50 V DC, max. 200 ma, rating 5 W PROFIBUS PA protocol Layer 1 and 2, Class A, Profile 3.01 Performance (Reference conditions according to IEC ) Non-linearity Greater of 25 mm (1 inch) or 0.25 % of span (including hysteresis and non-repeatability), over the full ambient temperature range Non-repeatability 10 mm (0. inch) Rated operating conditions Amb. temperature for enclosure C ( F) Location Indoor/outdoor Installation category II Pollution degree Medium conditions Dielectric constant ε r > 1. Process temperature range C ( F) Vessel pressure 0.5 bar g (7.25 psi g) maximum Design Weight Approx. 6.1 kg (13. lb) with 3 inch universal flange Materials Enclosure Die-cast aluminum, painted Degree of protection IP67/Type X/NEMA X/ Type 6/NEMA 6 Cable inlet 2x M20x1.5 or ½" NPT Process connections Universal flanges, 30 stainless steel, flat faced, with integral Easy Aimer 3 inch/80 mm, inch/100 mm, 6 inch/150 mm (mates with flange EN , ASME B16.5, or JIS B2238 bolt pattern), 0.5 bar g (7.25 psi g) max. pressure Programming Intrinsically Safe Siemens handheld Infrared receiver programmer (ordered separately) Approvals for handheld programmer IS model with ATEX II 1G EEx ia IIC T, CSA/FM Class I, Div. 1, Groups A, B, C, D T6 at max. ambient temperature of 0 C (10 F) Handheld communicator HART Communicator 375 PC SIMATIC PDM Display (local) Alphanumeric LCD for readout and entry Power supply V AC ± 15 % (50/60 Hz), 6 W (12 VA) or 2 V DC +25/-20 %, 6 W (optional) Certificates and approvals General CSA US/C, CE, FM, RCM Radio European Radio (R&TTE), Industry Canada, FCC, RCM Hazardous Areas CSA/FM Class II, Div. 1, Groups E, F and G, Class III ATEX II 1D, 1/2 D, 2D T85 C INMETRO ExtD A20 IP67 T85 C GOST Ex DIP A20 T a 85 C IP67 Optional equipment Dust cap PTFE Air purge connection 1/8" NPT Siemens FI 01 June 2015 /275

276 Continuous level measurement - Radar transmitters SITRANS LR60 SITRANS LR60 7ML526- -wire, 2 GHz FMCW radar level transmitter with extremely high signal-to-noise ratio and advanced signal processing for continuous monitoring of solids up to 100 m (328 ft). It is ideal for measurement in extreme dust. Order handheld programmer separately Click on the for the online configuration in the PIA Life Cycle Portal. Process connection Universal, flat faced, 0.5 bar g (7.25 psi g) maximum with integral Easy Aimer ball 3 inch (80 mm) A inch (100 mm) B 6 inch (150 mm) C Antenna 3" horn antenna, fits 80 mm (3 inch) nozzles A 3" horn antenna, fits 80 mm (3 inch) nozzles with B 100 mm extension 3" horn antenna, fits 80 mm (3 inch) nozzles with C 200 mm extension 3" horn antenna, fits 80 mm (3 inch) nozzles with D 500 mm extension 1) 3" horn antenna, fits 80 mm (3 inch) nozzles with E mm extension 1) " horn antenna, fits 100 mm ( inch) nozzles F " horn antenna, fits 100 mm ( inch) nozzles with G 100 mm extension " horn antenna, fits 100 mm ( inch) nozzles with H 200 mm extension " horn antenna, fits 100 mm ( inch) nozzles with J 500 mm extension 1) " horn antenna, fits 100 mm ( inch) nozzles with K mm extension 1) Purge (self-cleaning) connection No purge connection 0 Purge connection 1 Output/Communication ma, HART 0 PROFIBUS PA 1 Power supply/cable inlet V AC 2 x M20x1.5 A 2 x ½" NPT B 2 V DC 2 x M20x1.5 C 2 x ½"NPT D Approvals General Purpose, CSAUS/C, Industry Canada, FM, A FCC, CE and R&TTE, RCM CSA/FM Class II, Div. 1, Groups E, F, and G, B Class III ATEX II 1/2 D T6, CE, R&TTE C 1) Available with Purge option 0 only Order code Further designs Please add "-Z" to and specify Order code(s). Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Y15 Measuring-point number/identification (max. 27 characters); specify in plain text Manufacturer's test certificate: M to DIN 55350, C11 Part 18 and to ISO 9000 Operating Instructions English 7ML1998-5JM02 French 7ML1998-5JM11 German 7ML1998-5JM32 Multi-language Quick Start manual A5E This device is shipped with the Siemens Milltronics manual DVD containing the ATEX Quick Start and Operating Instructions library. Accessories Handheld programmer, Infra-red, Intrinsically Safe, 7ML5830-2AJ EEx ia Dust cap, PTFE, for 3 inch/80 mm horn 7ML1930-1BL Dust cap, PTFE, for inch/100 mm horn 7ML1930-1BM HART modem/usb 7MF997-1DB (for use with a PC and SIMATIC PDM) One metallic cable gland M20x1.5, 7ML1930-1AP rated C ( F), HART 1) One metallic cable gland M20x1.5, 7ML1930-1AQ rated C ( F), PROFIBUS PA 1) SITRANS RD100, loop powered display - 7ML see Chapter 7 SITRANS RD200, universal input display with 7ML Modbus conversion - see Chapter 7 SITRANS RD300, dual line display with totalizer 7ML and linearization curve and Modbus conversion - see Chapter 7 SITRANS RD500 web, universal remote monitoring 7ML solution for instrumentation - see Chapter 7 For applicable back up point level switch - see point level measurement section 1) Product shipped with plastic cable gland, rated to -20 C. If -0 C rating required, then metallic cable gland is recommended. /276 Siemens FI 01 June 2015

277 Continuous level measurement - Radar transmitters SITRANS LR60 Dimensional drawings SITRANS LR60 (7ML526) 20 (8.0) Connection cover Electronics cover Purge connection 287 (11.29) Easy Aimer ball locking bolts Universal slotted flange Optional horn extension(s) 100/200/ 500/1 000 (3.93/7.87/ 19.68/39.37) 228 (8.97) Reference point 285 (11.22) Horn antenna 7.5 (2.93) 97.5 (3.8) SITRANS LR60, dimensions in mm (inch) Siemens FI 01 June 2015 /277

278 Continuous level measurement - Radar transmitters SITRANS LR60 Schematics AC version DC version Hand programmer Earth terminal Earth terminal Cable clamp Cable clamp HART HART SITRANS LR60 Part number: 7ML5830-2AJ Earth terminal Earth terminal Cable clamp Cable clamp PROFIBUS PA PROFIBUS PA Notes Recommended torque on terminal clamping screws, Nm ma, PROFIBUS PA, DC input circuits, AWG, shielded copper wire AC input circuit, min. 1 AWG copper wire All field wiring must have insulation suitable for at least 250 V The equipment must be protected by a 15 A fuse or circuit breaker in the building installation SITRANS LR60 connections /278 Siemens FI 01 June 2015

279 Continuous level measurement - Radar transmitters SITRANS LR260/LR60 Specials Selection and ordering data SITRANS LR260/LR60 Specials SITRANS LR260/LR60 Specials Process connection part kits - non-pressure-rated Enclosure with electronics (LR60) LR260/LR60,100 mm extension for horn antenna, no purge 1) A5E LR260/LR60, 200 mm extension for horn antenna, no purge 1) A5E LR260/LR60,100 mm extension for horn antenna with purge 1) LR260/LR60, 200 mm extension for horn antenna with purge 1) LR260/LR60, horn 2", no purge, no emitter 1) LR260/LR60, horn 3", no purge, no emitter 1) LR260/LR60, horn ", no purge, no emitter 1) LR260/LR60, horn 2", with purge, no emitter 1) LR260/LR60, horn 3", with purge, no emitter 1) LR260/LR60, horn ", with purge, no emitter 1) LR260/LR60, 3" universal flat faced flange 1) LR260/LR60, " universal flat faced flange 1) LR260/LR60, 6" universal flat faced flange 1) LR260/LR60 O-rings for Easy Aimer 1) Kit, Emitter for LR260/LR60 1) LR260 lid with O-ring Purge conversion kit non-pressure-rated (no flange or extension included) LR260/LR60 purge conversion, 2" horn 1) LR260/LR60 purge conversion, 3" horn 1) LR260/LR60 purge conversion, " horn 1) Enclosure with electronics A5E A5E A5E A5E A5E A5E A5E A5E A5E A5E A5E A5E A5E A5E A5E A5E A5E LR60 enclosure with board stack, HART communication, AC power, M20 cable inlet, approval option A, no process connection LR60 enclosure with board stack, PROFIBUS PA communication, AC power, M20 cable inlet, approval option A, no process connection LR60 enclosure with board stack, HART communication, AC power, NPT cable inlet, approval option A, no process connection LR60 enclosure with board stack, PROFIBUS PA communication, AC power, NPT cable inlet, approval option A, no process connection LR60 enclosure with board stack, HART communication, DC power, M20 cable inlet, approval option A, no process connection LR60 enclosure with board stack, PROFIBUS PA communication, DC power, M20 cable inlet, approval option A, no process connection LR60 enclosure with board stack, HARTcommunication, DC power, NPT cable inlet, approval option A, no process connection LR60 enclosure with board stack, PROFIBUS PA communication, DC power, NPT cable inlet, approval option A, no process connection A5E A5E A5E A5E A5E A5E A5E A5E LR260 enclosure with board stack, HART communication, M20 cable inlet, approval option A, no process connection A5E ) Available with no pressure rating, 0.5 bar g maximum. Please contact ceg.smpi@siemens.com for special requests. LR260 enclosure with board stack, PROFIBUS PA communication, M20 cable inlet, approval option A, no process connection A5E LR260 enclosure with board stack, HART communication, NPT cable inlet, approval option A, no process connection A5E LR260 enclosure with board stack, PROFIBUS PA communication, NPT cable inlet, approval option A, no process connection A5E Sitrans LR260 enclosure with board stack, HART communication, NPT cable inlet, approval option D, no process connection A5E Sitrans LR260 enclosure with board stack, HART communication, M20 cable inlet, approval option E, no process connection A5E LR260 enclosure with board stack, HART communication, NPT cable inlet, approval option F, no process connection A5E LR260 enclosure with board stack, PROFIBUS PA communication, M20 cable inlet, approval option F, no process connection A5E Siemens FI 01 June 2015 /279

280 Continuous level measurement - Radar transmitters SITRANS LR560 Overview Configuration Installation Note: Beam angle is the width of the cone where the energy density is half of the peak energy density Emission The peak energy density cone is directly in front of and in line with the antenna There is signal transmitted outside of the beam angle; therefore false targets may be detected SITRANS LR560 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids in silos to a range of 100 m (329 ft). Benefits Rugged stainless steel design for industrial applications 78 GHz high frequency provides very narrow beam, virtually no mounting nozzle noise, and optimal reflection from sloped solids Aimer option to direct beam to area of interest, such as draw point of cone Lens antenna is highly resistant to product build-up Air purge connection is included for self-cleaning of extremely sticky solids Local display interface (LDI) allows local programming and diagnostics Application SITRANS LR560 s plug and play performance is ideal for most solids applications, including those with extreme dust and high temperatures to 200 ºC (392 ºF). Unique design allows safe and simple programming using the Intrinsically Safe handheld programmer without having to open the instrument s lid. SITRANS LR560 includes an optional graphical local display interface (LDI) that improves setup and operation using an intuitive Quick Start Wizard, and echo profile display for diagnostic support. Startup is easy using the Quick Start wizard with a few parameters required for basic operation. SITRANS LR560 measures practically any solids material to a range of 100 m (328 ft). Key Applications: cement powder, plastic powder/pellets, grain, coal, wood powder, fly ash Aiming will assist in measuring material in the cone SITRANS LR560 installation, dimensions in mm (inch) /280 Siemens FI 01 June 2015

281 Continuous level measurement - Radar transmitters SITRANS LR560 Technical specifications Mode of operation Measuring principle Frequency Minimum detectable distance Maximum measuring range 1) Output Analog output Communications Fail-safe Radar level measurement 78 GHz FMCW 00 mm (15.75 inch) from sensor reference point 0 m (131 ft) version 100 m (328 ft) version ma HART Optional: PROFIBUS PA Optional: FOUNDATION Fieldbus Programmable as high, low or hold (Loss of Echo) NE3 programmable Performance (according to reference conditions IEC ) Maximum measured error (including 5 mm (0.2 inch) hysteresis and non-repeatability) 2) Rated operating conditions (according to reference conditions IEC ) Installation conditions Location Indoor/outdoor Ambient conditions (enclosure) Ambient temperature C ( F) Installation category I Pollution degree Medium conditions Dielectric constant ε r > 1.6 Process temperature and pressure See chart below Design Enclosure Construction 316L/1.0 stainless steel Conduit entry M20x1.5, or ½" NPT via adapter Purge inlet 1/8" NPT, 30 cfm at max. 100 psi Lens material 0 m version: PEI 100 m version: PEEK Damage to lens could result from continuous purging/cleaning due to abrasive solids. Recommended purging/cleaning only a few seconds every hour Degree of protection Type X/NEMA X, Type 6/NEMA 6, IP68 with lid closed Weight 3.15 kg (6.9 lb) including 3 inch flange Optional local display interface Graphic LCD, with bar graph representing level Process connections Universal flat-faced flanges 3) Aimer flanges 3) 3,, 6 inch/80, 100, 150 mm, 30 stainless steel 3,, 6 inch/80, 100, 150 mm, 316L/1.0 or 316L/1.35 stainless steel 3,, 6 inch/80, 100, 150 mm, polyurethane powder-coated cast aluminum Power supply ma/hart Nominal 2 V DC (max. 30 V DC) with max. 550 Ω PROFIBUS PA/ FOUNDATION Fieldbus Certificates and approvals General Radio 1) From sensor reference point 2) Under severe EMI/EMC environments per IEC or NAMUR NE21, the device error may increase to a maximum of 25 mm (1 inch) 3) Universal flange mates with EN (PN16)/ASME B16.5 (150 lb)/ JIS 2220 (10K) bolt hole pattern. Process temperature and pressure 13.5 ma V DC, per IEC CSA US/C, CE, FM Europe (R&TTE), FCC, Industry Canada, RCM Hazardous Europe/International IECEx SIR X ATEX II 1D, 1/2D, 2D Ex ta IIIC T139 ºC Da IP68 ATEX II 3G Ex na II T Gc Ex nl IIC T Gc US/Canada FM/CSA Class II, Div. 1, Groups E, F, G Class III T FM/CSA Class I, Div. 2, Groups A, B, C, D, T China NEPSI Ex na II T Ex nl IIC T DIP A20 TA, T139 ºC, IP68 Brazil INMETRO BR-Ex na/nl II T IP68 Programming Intrinsically Safe Siemens handheld Infrared receiver programmer Approvals for handheld programmer IS model: ATEX II 1GD Ex ia IIC T Ga Ex iad 20 T135 C T a = C CSA/FM Class I, II, and III, Div. 1, Groups A, B, C, D, E, F, G, T6 T a =50 C Handheld communicator HART communicator 375/75 PC SIMATIC PDM, AMS, PACTware Display (local) Graphic local user interface including quick start wizard and echo profile displays Version Stainless steel Aimer flange: bar 0 m C ( F) 100 m C ( F) C ( F) C ( F) Aimer flange: bar C ( F) C ( F) Siemens FI 01 June 2015 /281

282 Continuous level measurement - Radar transmitters SITRANS LR560 SITRANS LR560 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids in silos to a range 7ML of 100 m (329 ft). Order handheld programmer separately Click on the for the online configuration in the PIA Life Cycle Portal. Measurement and process temperature range 0 m (131 ft) max range, C m (329 ft) max range, C 1 Process connection Universal flat-faced flange fits ANSI/DIN/JIS flanges 3 inch/80 mm, 30 stainless steel A inch/100 mm, 30 stainless steel B 6 inch/150 mm, 30 stainless steel C 3 inch/80 mm, 316L stainless steel D inch/100 mm, 316L stainless steel E 6 inch/150 mm, 316L stainless steel F 3 inch/80 mm, painted aluminum, with integral aimer 1) G inch/100 mm, painted aluminum, with integral H aimer 1) 6 inch/150 mm, painted aluminum, with integral J aimer 1) Enclosure (with cable inlet) Stainless steel, 1 X ½" NPT A Stainless steel, 1 X M20 x 1.5 B (plastic gland included) Pressure rating 0.5 bar g (7.5 psi g) maximum 0 3 bar g (0 psi g) maximum 1 Output/communication ma, HART A PROFIBUS PA B FOUNDATION Fieldbus C Approvals General Purpose, CSA US/C, Industry Canada, FCC, A CE, R&TTE, RCM CSA/FM Class I, Div. 2, Groups A, B, C, D, Class II, B Div.1, Groups E, F, G, Class III ATEX II 1 D, ½ D, 2 D, 3G Ex na/nl, CE, R&TTE, C RCM Local display interface Without LDI (local display interface) 1 With LDI (local display interface) 2 1) Rated to 120 ºC max. when used with Pressure rating option 1 We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 9/5 in the appendix. Order code Further designs Please add "-Z" to and specify Order code(s). Plug M12 with mating connector 1)2)3) A50 Plug 7/8" with mating connector 1)3)7) A55 Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Y15 Measuring-point number/identification (max. 27 characters); specify in plain text Manufacturer's test certificate: M to DIN 55350, C11 Part 18 and to ISO 9000 Inspection Certificate Type 3.1 per EN 1020 ) C12 NAMUR NE3 compliant, device preset to failsafe <3.6mA 5) N07 Operating Instructions for HART device English A5E36796 German 7ML1998-5KB32 Multi-language Quick Start manual A5E This device is shipped with the Siemens Milltronics manual DVD containing the ATEX Quick Start and Operating Instructions library. Operating Instructions for PROFIBUS PA device English A5E36871 German 7ML1998-5LT32 Multi-language Quick Start manual A5E This device is shipped with the Siemens Milltronics manual DVD containing the ATEX Quick Start and Operating Instructions library. Operating Instructions for FOUNDATION Fieldbus device English A5E German 7ML1998-5LY32 Multi-language Quick Start manual A5E This device is shipped with the Siemens Milltronics manual DVD containing the ATEX Quick Start and Operating Instructions library. Accessories Hand Programmer, Intrinsically safe 7ML1930-1BK Local display interface 7ML1930-1FJ Sun Shield Cover, 30 stainless steel 7ML1930-1FK Housing lid with window 7ML1930-1FL One metallic cable gland M20x1.5, 7ML1930-1AP rated C ( F), HART 6) One metallic cable gland M20x1.5, 7ML1930-1AQ rated C ( F), PROFIBUS PA 6) SITRANS RD100, loop powered display - see Chap. 7 7ML SITRANS RD200, universal input display with 7ML Modbus conversion - see Chapter 7 SITRANS RD300, dual line display with totalizer and 7ML linearization curve and Modbus conversion - see Chapter 7 SITRANS RD500 web, universal remote monitoring 7ML solution for instrumentation - see Chapter 7 For applicable back up point level switch - see point level measurement section 1) Available with Approval option A only 2) Available with Enclosure option B only 3) Available with Output/communication options B and C only ) Available with Pressure rating option 1 only 5) Available with Output/communication option A only 6) Product shipped with plastic cable gland, rated to -20 C. If -0 C rating required, then metallic cable gland is recommended 7) Only available with enclosure option A (NPT thread) We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 9/5 in the appendix /282 Siemens FI 01 June 2015

283 Continuous level measurement - Radar transmitters SITRANS LR560 Options Handheld programmer Part number: 7ML1930-1BK Sun shield cover (30 stainless steel) Part number: 7ML1930-1FK SITRANS LR560 handheld programmer and sun shield cover Siemens FI 01 June 2015 /283

284 Continuous level measurement - Radar transmitters SITRANS LR560 Characteristic curves Temperature derating curve Ambient temperature Process temperature Ambient temperature ( C) m version 100 m version Process temperature ( C) SITRANS LR560 temperature derating curve Dimensional drawings Flat flange 3 aimer flange and 6 aimer flange* Lid lock Cable gland Grounding lug Purge plug Process connection: flat flange 176 (6.93) Cable gland Grounding lug Purge plug Process connection: 3 aimer flange (6.5) 22.3 (0.92) Cable gland Grounding lug Purge plug Process connection: and 6 aimer flange (6.5) A Sensor reference point 110 (.33) 200 (7.87) 9.6 (0.38) 200 (7.87) 110 (.33) : 229 (9.02) 6 : 285 (11.22) 110 (.33) 9.6 (0.38) 10º max. * C Spanner wrench included 5º max. A5E A 53.2 (2.09) 6 60 (2.36) SITRANS LR560, dimensions in mm (inch) /28 Siemens FI 01 June 2015

285 Continuous level measurement - Radar transmitters SITRANS LR560 Specials Schematics Selection and ordering data SITRANS LR560 Specials Cable gland (or NPTcable entry) LR560 Electronics Modules Cable shield (if used) LR560 Electronics Module, HART, 100 m range, compatible with 7ML501XX00XAXX, no enclosure or process connection included. 7ML1830-3AC Connect the wires to the terminals as shown: the polarity is identified on the terminal block. LR560 Electronics Module, PROFIBUS PA, 100 m range, compatible with 7ML501XX00XBXX, no enclosure or process connection included. LR560 Electronics Module, FOUNDATION Fieldbus,100 m range, compatible with 7ML501XX00XCXX, no enclosure or process connection included. LR560 Electronics Module, HART, 0 m range, compatible with 7ML500XX00XAXX, no enclosure or process connection included. 7ML1830-3AH 7ML1830-3AJ 7ML1830-3AK Notes: 1. Depending on the approval rating, glands and plugs may be supplied with your instrument. 2. DC terminal shall be supplied from a source providing electrical isolation between the input and output, to meet the applicable safety requirements of IEC All field wiring must have insulation suitable for rated input voltages.. Use shielded twisted pair cable ( AWG) for HARTversion. 5. Separate cables and conduit may be required to conform to standard instrumentation wiring practices or electrical codes. LR560 Electronics Module, PROFIBUS PA, 0 m range, compatible with 7ML500XX00XBXX, no enclosure or process connection included. LR560 Electronics Module, FOUNDATION Fieldbus, 0 m range, compatible with 7ML500XX00XCXX, no enclosure or process connection included. LR560 Miscellaneous Spare Kits 7ML1830-3AL 7ML1830-3AM SITRANS LR560 connections Kit, Lid Gasket, EPDM, LR560 Kit, Wrench for " and 6" Aimers, LR560 7ML1830-3AA 7ML1830-3AB Kit, O-rings for 3" Aimer, LR560 7ML1830-3AD Kit, O-rings for " Aimer, LR560 7ML1830-3AE Kit, O-rings for 6" Aimer, LR560 7ML1830-3AF Kit, Lid Screw and Purge Plug set with Hex Keys, LR560 7ML1830-3AG Kit, Lid, No Window, LR560 7ML1830-3AP Please contact ceg.smpi@siemens.com for special requests. Siemens FI 01 June 2015 /285

286 Guided wave radar transmitters Guided wave radar transmitters Overview Mode of operation Introduction Interface Detection Guided Wave Radar transmitters use TDR (time domain reflectometry). upper level and an interface level. The upper liquid must have a The SITRANS LG, is a transmitter capable of measuring both an dielectric constant between 1.6 and 10 and the two liquids have Time Domain Reflectometry (TDR) a difference in dielectric constants greater than 10. A typical application would be oil over water, with the upper layer of oil being TDR uses pulses of electromagnetic (EM) energy to measure distances or levels. When a pulse reaches a dielectric discontinuity (created by media surface), part of the energy is reflected. the lower layer of water being very conductive with a dielectric non-conductive with a dielectric constant of approximately 2 and The greater the dielectric difference, the greater the amplitude constant of approximately 80. This interface measurement can (strength) of the reflection. only be accomplished when the dielectric constant of the upper medium is lower than the dielectric constant of the lower medium. The SITRANS LG includes a transmitter and waveguide that has a characteristic impedance in air and is used as a probe. When part of the probe is immersed in a material other than air, there is lower impedance due to the increase in the dielectric. When an EM pulse is sent down the probe and meets the dielectric discontinuity, a reflection is generated. 2 V DC, ma loop powered Air: (dk = 1) Transmit pulse A reflection develops from the liquid surface. Air: dk = 1 A small amount of energy continues down the probe in a low dielectric fluid. Upper Level Signal Interface Level Signal Low dielectric medium (e.g. oil: dk = 2) Emulsion layer High dielectric medium (e.g. water: dk = 80) Media dk > 1. /286 Siemens FI 01 June 2015

287 Guided wave radar transmitters Guided wave radar transmitters Application cst (like water) cst (like machine oil) cst (like cooking oil) cst (like honey) cst (like syrup/molasses) inch) inch) inch) inch) inch) Update 03/2015 Siemens FI 01 June 2015 /287

288 Guided wave radar transmitters Guided wave radar transmitters Guided Wave Radar (Interface) Application Questionnaire Customer information Contact: Company: Address: City: Zip/Postal Code: Tank/Vessel Information Tank top: Open Flat Conical Parabolic Pressure: Normal: Maximum (relief): Interface Data Tank bottom: Sloped Flat Conical Parabolic Country: Phone: ( ) Fax: ( ) (supply sketch where possible) Mounting location: Top mount Thread mount Sketch attached Flange mount Bypass/Sidepipe Mount Pipe mount Displacer replacement (please supply drawings) Prepared By: Date: Notes on the Application: Tank dimensions: Height: Diameter: Nozzle Length: Nozzle Diameter: Process connection type: Process connection size: Distance to sidewall: m/ft m/ft cm/inch cm/inch cm/inch Upper material: Lower material: Emulsion layer: Yes Upper material thickness: Upper material dielectric: cm/inch Lower material thickness: Lower material dielectric: cm/inch Emulsion thickness: No (preferred) cm/inch Material Material being measured: Liquid Slurry Material temperature: Norm: C/ F Max: C/ F Coating buildup: Yes No Turbulence: Yes No Maximum Viscosity: Density: kg/m 3 Kinematic Viscosity (cst) = Dynamic Viscosity (cp) / Density (kg/m ) cst (like water) cst (like honey) cst (like machine oil) cst (like syrup/molasses) cst (like cooking oil) >500 cst (like tar) Emulsion layer Upper material Lower material Installation Power available: Communications: HART/ ma Outputs required:...20 ma Other (please specify) Products recommended: Siemens Milltronics Process Instruments Inc. Update 03/2015 /288 Siemens FI 01 June 2015

289 Guided wave radar transmitters SITRANS LG series Overview Configuration Mounting on nozzle Flange Metal sheet The Siemens SITRANS LG series are guided wave radar transmitters for level, level/interface, and volume measurement of liquids and solids. The Sitrans LG product line can handle changes in process conditions, high temperatures and pressures, and steam. Benefits High accuracy to +/- 2 mm Advanced Diagnostics available for high degree of safety Simple menu driven display offers ease of setup Large range of options offers reliability in most continuous measurement applications Ease of maintenance through module design and field replaceable and adjustable probe options Perfect solution for wide range of applications from storage to interface with options for extreme pressure and temperature conditions Universally applicable in liquids, interface, slurries and solids Highly immune to build-up using auto learn function Wide range of Hygienic options Installation in non-metal vessel The guided microwave principle requires a metal surface on the process fitting. Therefore, use in plastic vessels etc. an instrument version with flange (from DN 50) or place a metal sheet, Ø > 200 mm (8 inch), beneath the process fitting when screwing it in. Make sure that the plate has direct contact with the process fitting Mounting socket d) d DN 0... DN 150 > DN DN 200 h) h < 150 < 100 If possible, avoid sockets, mount the sensor flush with the vessel top. If this is not possible, use short sockets with small diameter. Higher sockets or sockets with a bigger diameter can generally be used. They simply increase the upper blocking distance. Check if this is relevant for your measurement. In such cases, always carry out a false signal suppression after installation. Socket must be installed flush Application The SITRANS LG series comes in four different models, depending on the applications, level of performance, and functionality required: SITRANS LG20 offers configuration options for your hygienic and corrosive application requirements SITRANS LG250 Highly flexible solution for liquid level and interface applications. Extremely versatile offering solutions for storage, separation of materials or difficult ammonia applications SITRANS LG260 Ideal for measuring level in medium range solids applications including; grains, plastics, and cement SITRANS LG270 offers configuration options for extreme conditions including high temperature and high pressure applications such as: harsh applications found in chemical, HPI and energy industries for example, LPG gas tanks, steam boilers and distillation columns When welding the socket, make sure that the socket is flush to the vessel top. Before beginning the welding work, remove the electronics module from the sensor. By doing this, you avoid damage to the electronics through inductive coupling. Inflowing medium Do not mount the instruments in or above the filling stream. Make sure that you detect the product surface, not the inflowing product. SITRANS LG Series installation Siemens FI 01 June 2015 /289

290 Guided wave radar transmitters SITRANS LG series Technical specifications Mode of operation Measuring principle Measuring range Output ma analog output with HART digital signal Output range Analog Start-up current Diagnostic alarm Digital communication Modbus PROFIBUS PA Performance Non-linearity Coaxial Single rod probes Interface models Resolution and repeatability Accuracy Coaxial/rod/cable probes Interface models Electromagnetic compatibility (check if needed) Measuring cycle time Step response time Temperature Effects Rated operating conditions Ambient temperature for enclosure LCD readable temperature range Location Installation category Pollution degree 2 Relative Humidity % Medium conditions Dielectric constant Process temperature range Vessel pressure Guided wave radar measurement mm ( inch) ma/hart (SIL optional) Current: minimum 3.8 ma, maximum 20.5 ma 10 ma for 5 ms after switching on, 3.6 ma Failure signal current output (adjustable): last valid measured value, 21 ma, 3.6 ma HART Version 7 x and multidrop compatible Modbus RTU, Modbus ASCII Process reference conditions according to DIN EN See manual for more details Accuracy +/- 2 mm (0.08 inch) ± 2 mm (0.08 inch) ± 5 mm (0.197 inch) (Note: Typical deviation, Interface measurement) See manual for more details < 500 ms 3s The measurement error from the process conditions is in the specified pressure and temperature range of below 1 % C ( F) C ( F) with display heated option Indoor/outdoor II dk 1. (configuration dependent) Note: for measurement below 1. use probe end tracking C ( F) bar ( kpa) Design Instrument weight (dependent on process fitting) - see manual for further details Materials Enclosure Degree of protection Cable inlet Approx kg ( lb) Plastic housing plastic PBT (Polyester) Aluminum die-casting housing, aluminum die-casting AISi10 mg, powder-coated- basis: polyester Stainless steel housing, precision casting 316L Stainless steel housing, electropolished 316L Type /NEMA, IP65 Plastic housing IP66/IP67 Aluminum and stainless steel housings are IP 66/68 2x M20x1.5 or 2 x ½" NPT Process connections Pipe thread, cylindrical (ISO 228 T1) G¾" A, G1" A, G1½" A according to DIN 3852-A American pipe thread, conical ¾" NPT, 1" NPT, 1½" NPT (ASME B1.20.1) Flanged DIN from DN 25, ANSI from 1" Hygienic Hygienic fittings Programming Local Four button, menu-driven data entry Handheld communicator Hart communicator PC SIMATIC PDM, AMS, PACTware Power 2 wire Hart version V DC wire versions V DC, 20 2 V AC, 50/60 Hz and V AC, 50/60 Hz Modbus 8 30 V DC PROFIBUS PA VDC Note: see manual for specific power based on ordered options Certificates and approvals Hazardous approvals: ATEX, FM, CSA, IECex Hygienic approvals: EHEDG Overfill protection WHG Ship approval ABS, CCS, GL /290 Siemens FI 01 June 2015

291 Guided wave radar transmitters SITRANS LG series Industries Applications SITRANS LG20 SITRANS LG250 SITRANS LG260 SITRANS LG270 Food, Beverage and Chemical/HPI/Power/General Cement, power generation, Chemical/HPI/Power/General Pharmaceutical food, processing, mineral processing, mining Hygienic and corrosive applications Liquids, storage and process vessels with agitators, vaporous liquids, interface Cement, fly ash, grain, coal, flour, plastics Range 32 m 75 m 60 m 60 m Performance +/- 2 mm +/- 2 mm +/- 2 mm +/- 2 mm Temperature C ( F) Communications ma/hart Modbus: Modbus RTU, Modbus ASCII PROFIBUS PA SIMATIC PDM DTM/FDT for PACTware Fieldcare C ( F) ma/hart Modbus: Modbus RTU, Modbus ASCII PROFIBUS PA SIMATIC PDM DTM/FDT for PACTware Fieldcare C ( F) ma/hart Modbus: Modbus RTU, Modbus ASCII PROFIBUS PA SIMATIC PDM DTM/FDT for PACTware Fieldcare Aggressive applications in liquids, storage and process vessels with agitators, vaporous liquids, high temperatures and pressures, low dielectric media C ( F) ma/hart Modbus: Modbus RTU, Modbus ASCII PROFIBUS PA SIMATIC PDM DTM/FDT for PACTware Fieldcare Siemens FI 01 June 2015 /291

292 Guided wave radar transmitters SITRANS LG series Order Code SITRANS LG20 7ML5880- Guided Wave Radar sensor for Hygienic and corrosive continuous level and interface measurement of liquids. Click on the for the online configuration in the PIA Life Cycle Portal. Approvals Ordinary location CE 9) 0 A ATEX II 1G, 1/2G, 2G Ex ia IIC T6 9) 0 E ATEX II 1G,1/2G 2G Ex ia IIC + ATEX II 1D,1/ 0 H 2D, 1/3D, 2D, Ex t IIIC IP66 T 11)13)15)2) ATEX II 1/2G, 2G Ex d ia IIC T6 1)12) 0 J ATEX II 1/2G, 2G Ex d ia IIC + ATEX II 1/2D, 0 K 2D IP6x 1)11)12)13)15)2) ATEX II 1D, 1/2D, 1/3D, 2D, Ex t IIIC IP66 0 N T 11)13)15)2) IEC Ex ia IIC T6 9) 0 P IEC Ex ia IIC T6 + IEC IP6x T td 11)13)15)2) 0 Q IEC Ex d ia IIC T6 1)12) 0 R IEC Ex d ia IIC T6 + IEC IP6x T 0 S td 1)11)12)13)15)2) FM (NI) Class I, Div. 2, Groups A, B, C, D 1 A FM (IS) Class I, II, III, Div. 1, Groups A, B, C, 1 B D, E, F FM(XP-IS) Class I, II, III, Div. 1, Groups A, B, 1 C C, D, E, F, G 1)12) CSA (NI) Class I, Div. 2, Groups A, B, C, D 1 E (DIP) Class II, III, Div. 1, Groups E, F, G 11)13)15) CSA (IS) Class I, II, III, Div. 1, Groups A, B, 1 F C, D, E, F, G CSA (XP-IS) Class I, II, III, Div. 1, Groups A, 1 G B, C, D, E, F, G 1)12) Probe version/material Probe cable ø mm (0.16 inch) with gravity A weight/pfa 2)7) Probe exchangeable rod (ø8 mm) / 1.35 B (BN2), can be autoclaved (Ra < 0.76 µm) 3)7) Probe exchangeable rod (ø8 mm) / 1.35 C (BN2),(Ra<0.76µm) 3)7) Probe rod ø10 mm (0.39 inch)/pfa 2)7) D Process fitting/material Clamp 2" PN 16 (ø6 mm) DIN 32676, 0 0 ISO2852/1.35 (BN2) ) Clamp 2" PN 16 (ø6 mm) DIN 32676, 0 1 ISO2852/PTFE-TFM 1600 Clamp 2 1/2" PN 10 (ø77.5 mm) DIN 32676, 0 2 ISO2852/1.35 (BN2) ) Clamp 2 1/2" PN 10 (ø77.5 mm) DIN 32676, 0 3 ISO2852/PTFE-TFM 1600 Clamp 3" PN 10 (ø91 mm) DIN 32676, 0 ISO2852/1.35 (BN2) ) Clamp 3" PN 10 (ø91 mm) DIN 32676, 0 5 ISO2852/PTFE-TFM 1600 Clamp " PN6 (ø119 mm) DIN 32676, 0 6 ISO2852/1.35(BN2) ) Clamp " PN6 (ø119 mm) DIN 32676, 0 7 ISO2852/PTFE-TFM 1600 Bolting DN 32, PN 0 DIN11851/ (BN2) ) Bolting DN 32, PN 0 DIN11851/PTFE-TFM Bolting DN 0, PN 0 DIN11851/ (BN2) ) Bolting DN 0, PN 0 DIN11851/PTFE-TFM Order Code SITRANS LG20 7ML5880- Guided Wave Radar sensor for Hygienic and corrosive continuous level and interface measurement of liquids Bolting DN 50, PN 25 DIN11851/ (BN2) ) Bolting DN 50, PN 25 DIN11851/PTFE-TFM Bolting DN 65, PN 25 DIN11851/PTFE-TFM Flange DN 25, PN 0 Form C, DIN 2501/ 2 0 PTFE-TFM 1600 Flange DN 0, PN 0 Form C, DIN 2501/ 2 1 PTFE-TFM 1600 Flange DN 50, PN 0 Form C, DIN 2501/ 2 2 PTFE-TFM 1600 Flange DN 50, PN 0 Form V13, DIN 2513/ 2 3 PTFE-TFM 1600 Flange DN 65, PN 0 Form C, DIN 2513/ 2 PTFE-TFM 1600 Flange DN 80, PN 0 Form C, DIN 2501/ 2 5 PTFE-TFM 1600 Flange DN 100, PN 16 Form C, DIN 2501/ 2 6 PTFE-TFM 1600 Flange DN 80, PN 0 EN Form B1/ 2 7 PTFE-TFM 1600 Flange DN 100, PN 0 EN Form B1/ 2 8 PTFE-TFM 1600 Flange 2" 150 lb RF, ANSI B16.5/PTFE-TFM Flange 2" 300 lb RF, ANSI B16.5/PTFE-TFM Flange 3" 150 lb RF, ANSI B16.5/PTFE-TFM Flange " 150 lb RF, ANSI B16.5/PTFE-TFM Note: The pressure limit for all PTFE coated versions is 16 bar (per manual). Electronics Two-wire... 20mA/HART 0 Four-wire Modbus 19)20)21)22) 1 Two-wire...20mA/HART with SIL 2 qualification 17)18) Four-wire...20mA/HART; V AC; 50/ 3 60 Hz 1)8)10) Four-wire...20mA/HART; V DC; V AC 1)8)10) PROFIBUS PA 5 Seal/Process temperature Without glass seal/ C A ( F) 5)11) FFKM (Kalrez 6221)/ C B ( F) EPDM (Freudenberg 70 EPDM 291)/ C C ( F) Housing/Protection/Cable Plastic IP66/IP67 M20x1.5/blind stopper A Plastic IP66/IP67 1/2" NPT/blind stopper B Aluminium/IP66/IP68 (0.2 bar) M20x1.5/blind C stopper Aluminium/IP66/IP68 (0.2 bar) 1/2" NPT/blind D stopper Aluminium double chamber/ip66/ip68 E (0.2 bar) M20x1.5/blind stopper Aluminium double chamber/ip66/ip68 F (0.2 bar) 1/2" NPT/blind stopper Stainless steel (precision casting) 316L/IP66/ IP68 (0.2 bar) M20x1.5/blind stopper G /292 Siemens FI 01 June 2015

293 Guided wave radar transmitters SITRANS LG series Order Code SITRANS LG20 7ML5880- Guided Wave Radar sensor for Hygienic and corrosive continuous level and interface measurement of liquids Stainless steel (precision casting) 316L/IP66/ H IP68 (0.2 bar) 1/2" NPT/blind stopper Stainless steel (electropolished) 316L/IP66/ J IP68 (0.2 bar) M20x1.5/blind stopper Stainless steel (electropolished) 316L/IP66/ K IP68 (0.2 bar) 1/2" NPT/blind stopper Stainless steel double chamber/ip66/ip68 L (0.2 bar) M20x1.5/blind stopper Stainless steel double chamber/ip66/ip68 M (0.2 bar) 1/2" NPT/blind stopper Aluminium/IP66/IP68 (0.2 bar) M20x1.5/ N cable gland stainless steel Aluminium double chamber/ip66/ip68 P (0.2 bar) M20x1.5/cable gland stainless steel Stainless steel (precision casting) 316L/IP66/ Q IP68 (0.2 bar) M20x1.5/Cable gland stainless steel Stainless steel (electropolished) 316L/IP66/ R IP68 (0.2 bar) M20x1.5/cable gland stainless steel Aluminium single chamber / IP66/IP68 W (0.2 bar) M20x1.5 / Cable gland brass nickel-plated Aluminium double chamber / IP66/IP68 X (0.2 bar) M20x1.5 / Cable gland brass nickel-plated Stainless steel single chamber (precision Y casting) / IP66/IP68 (0.2 bar) M20x1.5 / Cable gland brass nickel-plated Lengths Rod ø8 mm (0.31 inch)/1.35 (Basle standard mm) mm ( inch) 1) mm ( inch) 1) mm ( inch) 1) mm ( inch) 1) 3 Rod ø10 mm (0.2 inch)/pfa ( mm) 300 mm (11.81 inch) 1) 9 R 1 A 500 mm (19.69 inch) 1) 9 R 1 B mm ( inch) 1) 9 R 1 C mm ( inch) 1) 9 R 1 D mm ( inch) 1) 9 R 1 E mm 9 R 1 F ( inch) 1) Cable ø mm (0.16 inch)/pfa ( mm) 500 mm (9.69 inch) 9 R 1 G mm ( inch) 9 R 1 H mm ( inch) 9 R 1 J mm ( inch) 9 R 1 K mm ( inch) 9 R 1 L mm ( inch) 9 R 1 M mm ( inch) 9 R 1 N Further designs (mandatory) Please add "-Z" to and specify Order code(s). Supplementary electronics Without Additional current output ma 1)23) Local display interface Without Mounted Laterally mounted 1) Language of display German English French Dutch Italian Spanish Portuguese Russian Chinese Japanese Operating instructions German English French Spanish Further designs (optional) Please add "-Z" to and specify Order code(s). Enter the total insertion length in plain text description Enter the total length of rigid part Cleaning included certificate: oil, grease and silicone free Identification Label (measurement loop) stainless steel Identification Label (measurement loop) Foil 3.1-Inspection Certificate for material (EN 1020 NACE MR 0175) 16) 3.1-Inspection Certificate for instrument with test data (EN 1020) 16) 2.2-Factory certificate for material (EN 1020) 16) Quality and test plan 16) Dye penetration test certificate/instrument 16) X-ray test certificate/instrument 16) Positive material identification test certificate/ instrument 16) Roughness test certificate/instrument 16) Pressure test certificate/instrument 16) Helium leak test certificate/instrument 16) Ferrite measuring accuracy to DIN certificate/instrument 16) Pressure test according to Norsok certificate/ instrument 16) Order code A00 A01 E00 E01 E02 L00 L01 L02 L03 L0 L05 L06 L07 L08 L09 M00 M01 M02 M03 Order code Y01 Y02 W01 Y17 Y18 D07 C25 C15 C26 C13 C1 C16 C18 C31 C32 C60 C mm ( inch) mm ( inch) mm ( inch) 9 R 1 P 9 R 1 Q 9 R 1 R 5 point calibration certificate certificate/ instrument 16) C62 Siemens FI 01 June 2015 /293

294 Guided wave radar transmitters SITRANS LG series Additional Operating Instructions German 20 ma/hart - two-wire, PFA insulated PBD: ma/hart - two-wire, Polished version PBD: ma/hart - four-wire PFA insulated PBD: ma/hart - four-wire Polished version PBD: Modbus- PFA insulated PBD: Modbus protocol, Polished version PBD: PROFIBUS PA, PFA insulated PBD: PROFIBUS PA, polished version PBD: Note: Operating instructions should be ordered as a separate line on the order. This device is shipped with the Siemens Milltronics library. 1) Available with Housing/Protection/Cable options E,F, L, M only English 2) Available only with Process fitting/material options 01, 03, 05, 07, 10, 12, (PTFE versions) 20 ma/hart - two-wire PFA insulated 20 ma/hart - two-wire Polished version PBD: PBD: ) Available only with Process Fitting/Material options 00, 02, 0, 06, 08, 11, and 13 [1.35 (BN2) options] 20 ma/hart - four-wire PFA insulated 20 ma/hart - four-wire Polished version PBD: PBD: ) Available with Length options 0, 1, 2, 3 only (Rod ø8 mm 1.35 options) 5) Available with Length options R1A... R1R only (Rod ø10 mm/pfa and Cable ø mm/pfa options) Modbus, PFA insulated PBD: ) Available only with the same rod or cable diameter in Length options Modbus protocol, Polished version PBD: ) Available with Supplementary electronic option A00 and Local display interface options E00, E01 PROFIBUS PA, PFA insulated PBD: ) Available with Supplementary electronic option A01 and approval options 0A,0E, and 0P PROFIBUS PA, Polished version PBD: ) Available with Approval options 0A, 0J, 0K, 0N, 0R, OS, 1A,1 C, 1E, 1F, Note: Operating instructions should be ordered as a and 1G separate line on the order. 11) Available with Version/Material options A and D only 12) Available with Local display interface options E00 and E01 This device is shipped with the Siemens Milltronics manual DVD containing the operating instructions library. French 20 ma/hart - two-wire PFA insulated PBD: ma/hart - two-wire Polished version PBD: ma/hart - four-wire PFA insulated PBD: ma/hart - four-wire Polished version PBD: Modbus, PFA insulated PBD: Modbus protocol, Polished version PBD: PROFIBUS PA, PFA insulated PBD: PROFIBUS PA, Polished version PBD: Note: Operating instructions should be ordered as a separate line on the order. This device is shipped with the Siemens Milltronics manual DVD containing the operating instructions library. Spanish 20 ma/hart - two-wire PFA insulated PBD: ma/hart - two-wire Polished version PBD: ma/hart - four-wire PFA insulated PBD: ma/hart - four-wire Polished version PBD: Modbus, PFA insulated PBD: Modbus protocol, Polished version PBD: PROFIBUS PA, PFA insulated PBD: Note: Operating instructions should be ordered as a separate line on the order. This device is shipped with the Siemens Milltronics manual DVD containing the operating instructions library. Accessories SITRANS LG, GWR sensor Display Module SITRANS LG, USB communicator SITRANS RD100, loop powered display - see Chapter 7 SITRANS RD200, universal input display with Modbus conversion - see Chapter 7 SITRANS RD300, dual line display with totalizer and linearization curve and Modbus conversion - see Chapter 7 SITRANS RD500 web, universal remote monitoring solution for instrumentation - see Chapter 7 For applicable back up point level switch - see point level measurement section 13) Available with Seal/Process temperature C only 1) Not available with Y02 15) Available with Housing/Protection options C, D, E, F, G, H, L, M 16) Listed Certificates are not available with all configurations, please contact factory for more information 17) SIL electronic option 2 available with Approval options 0A, 0E, 0H, 0N, 0P, 0Q, 1A, 1B, 1E and 1F 18) Available with Supplementary electronic option A00, SIL electronics 19) Only available with Approval options 0A, 0J, 0K, 0R, 0S, 1A, 1C, 1E, and 1G 20) Available with housings/protection/cable options E, F, L, M and P 21) Available with supplementary electronic option A00 22) Available with Local display interface options E00, E01 23) Not available with Local display interface option E02 2) Available with Housing/protection options D, F, H and M Note: Please consult manual for further details. A5E3139 A5E ML ML ML ML /29 Siemens FI 01 June 2015

295 SITRANS LG250 A guided wave radar sensor for continuous level and interface measurement of liquids. Click on the for the online configuration in the PIA Life Cycle Portal. Approvals Ordinary location CE 16) Shipping approval 19)28)29) ATEX II 1G, 1/2G, 2G Ex ia IIC T6 16) ATEX II 1G, 1/2G, 2G Ex ia IIC T6 + shipping approval 19)28)29) ATEX II 1G,1/2G 2G Ex ia IIC + ATEX II 1D, 1/2D, 1/3D, 2D, Ex t IIIC IP66 16)23)0) ATEX II 1/2G, 2G Ex d ia IIC T6 1)21) ATEX II 1/2G, 2G Ex d ia IIC + ATEX II 1D, 1/2D, 1/3D, 2D, Ex t IIIC IP66 T 1)21)23)0) ATEX II 1/2G, 2G Ex d IIC T6 1)20) ATEX II 1/2G, 2G Ex d IIC + ATEX II 1D, 1/2D, 1/3D, 2D, Ex t IIIC IP66 T 1)20)23)0) ATEX II 1D, 1/2D, 1/3D, 2D, Ex t IIIC IP66 T 20)23)0) IEC Ex ia IIC 16) IEC Ex ia IIC T6 + IEC IP6x T td 16)20)23)0) IEC Ex d ia IIC T6 1)21)23)0) IEC Ex d ia IIC T6 + IEC IP6x T td 1)20)21)0) IEC Ex d IIC T6 1)20) IEC Ex d IIC T6 + IEC IP6x T td 1)20)23)0) FM (NI) Class I, Div. 2, Groups A, B, C, D FM (IS) Class I, II, III, Div. 1, Groups A, B, C, D, E, F Order Code 7ML A 0 B 0 E 0 G 0 H 0 J 0 K 0 L 0 M 0 N 0 P 0 Q 0 R 0 S 0 T 0 U 1 A 1 B FM(XP-IS) Class I, II, III, Div. 1, Groups A, B, C, D, E, F, G 1)21) 1 C FM (XP) Class I, Div. 1, Groups A, B, C, D 20) 1 D CSA (NI) Class I, Div. 2, Groups A, B, C,D 1 E (DIP) Class II, III, Div. 1, Groups E, F, G CSA (IS) Class I, II, III, Div. 1, Groups A, B, 1 F C,D, E, F, G CSA (XP-IS) Class I, II, III, Div. 1, Groups A, 1 G B, C, D, E, F, G 1)21) CSA (XP) Class I, II, III, Div. 1, Groups A, B, 1 H C, D, E, F, G 1)20) Probe version/material Probe exchangeable cable ø2 mm (0.08 inch) with gravity weight/316l 8)9)11)26) A Probe exchangeable cable ø2 mm B (0.08 inch) center weight/316l 8)9)12)26) Probe exchangeable cable ø mm C (0.16 inch) with gravity weight/316l 8)9)11)26) Probe exchangeable cable ø mm (0.16 inch) with center weight/316l 8)9)12)26) D Probe exchangeable rod E ø8 mm (0.31 inch)/316l 2)8)10)11)26) Probe exchangeable rod F ø12 mm (0.7 inch)/316l 3)8)10)11)2)26) Probe coax version ø21.3 mm (0.8 inch) with single hole/316l 8)9)11)26)27) G Probe coax version ø21.3 mm (0.8 inch) H with multiple hole/316l 8)9)11)26)27) Probe coax version ø2.2 mm (1.66 inch) K with multiple hole/316l 5)8)9)11)2)26)27) Guided wave radar transmitters SITRANS LG series Order Code SITRANS LG250 7ML5881- A guided wave radar sensor for continuous level and interface measurement of liquids Process fitting/material Thread G 3/" (DIN 3852-A) PN 6/316L 0 0 Thread 3/" NPT (ASME B1.20.1) PN 6/316L 0 1 Thread G 3/" (DIN 3852-A) PN 0/316L 0 2 Thread 3/" NPT (ASME B1.20.1) PN 0/316L 0 3 Thread G 3/" (DIN 3852-A) PN 100 / 316L 2) 0 Thread 3/" NPT (ASME B1.20.1) PN 100/ L 2) Thread G 1" (DIN 3852-A) PN 0/316L 0 6 Thread 1" NPT (ASME B1.20.1) PN 0/316L 0 7 Thread G 1" (DIN 3852-A) PN 100/316L 2) 0 8 Thread 1" NPT (ASME B1.20.1) PN 100/316L 2) 1 0 Thread G 1 1/2" (DIN 3852-A) PN 0/316L 1 1 Thread 1 1/2" NPT (ASME B1.20.1) PN 0/316L 1 2 Thread G1 1/2" (DIN 3852-A) PN 100/316L 2) 1 3 Thread 1 1/2" NPT (ASME B1.20.1) PN 100/ 1 316L 2) Thread 2 NPT PN 0, ASME B1.20.1/316L 37)38) 1 5 Flange DN 25 PN 0 Form C, DIN 2501/316L 2 0 Flange DN 25 PN 0 Form F, DIN 2501/316L 2 1 Flange DN 0 PN 0 Form C, DIN 2501/316L 2 2 Flange DN 50 PN 0 Form C, DIN 2501/316L 2 3 Flange DN 50 PN 0 form V13, DIN 2513/316L 2 Flange DN 80 PN 0 Form C, DIN 2501/316L 2 5 Flange DN 80 PN 0 Form V13, DIN 2501/316L 2 6 Flange DN 100 PN 16 Form C, DIN 2501/316L 2 7 Flange DN 100 PN 16 Form C, DIN 2501/ 316L 2 8 Flange DN 100 PN 0 Form C, DIN 2501 /316L 3 0 Flange DN 100 PN 0 Form V13, DIN 2513/316L 3 1 Flange DN 150 PN 16 Form C, DIN 2501/316L 3 2 Flange DN 50 PN 0 EN Form B1/316L 3 3 Flange DN 80 PN 0 EN Form B1/316L 3 Flange 1 1/2" 150 lb RF, ANSI B16.5/316L 3 5 Flange 2" 150 lb RF, ANSI B16.5/316L 3 6 Flange 2" 300 lb RF, ANSI B16.5/316L 3 7 Flange 3" 150 lb RF, ANSI B16.5/316L 3 8 Flange 3" 300 lb RF, ANSI B16.5/316L 0 Flange " 150 lb RF, ANSI B16.5/316L 1 Flange " 300 lb RF, ANSI B16.5/316L 2 Flange 6" 150 lb RF, ANSI B16.5 /316L 3 Flange 6" 300lb RF, ANSI B16.5/316L Flange 1 1/2" 150 lb RF, ANSI B16.5/316L 5 Electronics Two-wire... 20mA/HART 0 Four-wire Modbus 33)3)35)36) 1 Two-wire...20mA/HART with SIL 2 qualification 2)32) Four-wire...20mA/HART; V AC; 50/ 3 60Hz 1)15)17) Four-wire...20mA/HART; V DC; V AC 1)15)17) PROFIBUS PA 5 Siemens FI 01 June 2015 /295

296 Guided wave radar transmitters SITRANS LG series Order Code SITRANS LG250 7ML5881- A guided wave radar sensor for continuous level and interface measurement of liquids Seal/Second line of defense/ Process temperature FKM (SHS FPM 70C3 GLT)/ without glass A seal/ C ( F) 6) FKM (SHS FPM 70C3 GLT)/ without glass B seal/ C ( F) FKM (SHS FPM 70C3 GLT)/ with glass seal/ C C ( F) EPDM (A+P 75.5/KW75F)/ without glass D seal/ C ( F) EPDM (A+P 75.5/KW75F)/ with glass seal/ E C( F) FFKM (Kalrez 6375)/ with glass seal/ F C ( F) EPDM (A+P 75.5/KW75F)/ without glass G seal/ C ( F) 6) EPDM (A+P 75.5/KW75F)/ without glass H seal/ C ( F) EPDM (A+P 75.5/KW75F)/ with glass seal/ J C ( F) Silicone FEP coated (A+P FEP-O-SEAL)/ K without glass seal/ C ( F) 6) Silicone FEP coated (A+P FEP-O-SEAL)/ L without glass seal/ C ( F) Silicone FEP coated (A+P FEP-O-SEAL)/ with M glass seal/ C ( F) With borosilicate glass lead through/ with N glass seal/ C ( F) FFKM (Kalrez 6375)/ without glass seal/ P C ( F) FKM (SHS FPM 70C3 GLT)/ with glass seal/ C ( F) 6) Q Housing/Protection/Cable Plastic IP66/IP67 M20x1.5/blind stopper A Plastic IP66/IP67 1/2" NPT/blind stopper B Aluminium/IP66/IP68 (0.2 bar) M20x1.5/blind C stopper Aluminium/IP66/IP68 (0.2 bar) 1/2" NPT/blind D stopper Aluminium double chamber/ip66/ip68 E (0.2 bar) M20x1.5/blind stopper Aluminium double chamber/ip66/ip68 F (0.2 bar) 1/2" NPT/blind stopper Stainless steel (precision casting) 316L/IP66/ L IP68 (0.2 bar) M20x1.5/blind stopper Stainless steel (precision casting) 316L/IP66/ M IP68 (0.2 bar) 1/2" NPT/blind stopper Stainless steel (electropolished) 316L/IP66/ N IP68 (0.2 bar) M20x1.5/blind stopper Stainless steel (electropolished) 316L/IP66/ P IP68 (0.2 bar) 1/2" NPT/blind stopper Stainless steel double chamber/ip66/ip68 Q (0.2 bar) M20x1.5/blind stopper Stainless steel double chamber/ip66/ip68 R (0.2 bar) 1/2" NPT/blind stopper Aluminium/IP66/IP68 (0.2 bar) M20x1.5/ S cable gland stainless steel Aluminium double chamber/ip66/ip68 T (0.2 bar) M20x1.5/cable gland stainless steel Order Code SITRANS LG250 7ML5881- A guided wave radar sensor for continuous level and interface measurement of liquids Stainless steel (precision casting) 316L/IP66/ U IP68 (0.2 bar) M20x1.5/cable gland stainless steel Stainless steel (electropolished) 316L/IP66/ V IP68 (0.2 bar) M20x1.5/cable gland stainless steel Aluminium single chamber / IP66/IP68 W (0.2 bar) M20x1.5 / Cable gland brass nickel-plated Aluminium double chamber / IP66/IP68 X (0.2 bar) M20x1.5 / Cable gland brass nickel-plated Stainless steel single chamber (precision Y casting) / IP66/IP68 (0.2 bar) M20x1.5 / Cable gland brass nickel-plated Lengths Rod ø8 mm/316l mm ( inch) 22) mm ( inch) 22) mm ( inch) 22) mm ( inch) 22) mm ( inch) 22) mm ( inch) 22) 5 Rod ø12 mm/316l mm ( inch) 22) 9 R 2 A mm ( inch) 22) 9 R 2 B mm ( inch) 22) 9 R 2 C mm 9 R 2 D ( inch) 22) Cable lengths ø2 or mm/316l mm ( inch) 9 R 2 E mm ( inch) 9 R 2 F mm ( inch) 9 R 2 G mm ( inch) 9 R 2 H mm ( inch) 9 R 2 J mm ( inch) 9 R 2 K mm 9 R 2 L ( inch) mm 9 R 2 M ( inch) mm 9 R 2 N ( inch) mm 9 R 2 P ( inch) mm 9 R 2 Q ( inch) mm 9 R 2 R ( inch) mm 9 R 2 S ( inch) mm 9 R 2 T ( inch) mm 9 R 2 U ( inch) mm ( inch) 9 R 2 V /296 Siemens FI 01 June 2015

297 SITRANS LG250 A guided wave radar sensor for continuous level and interface measurement of liquids. Order Code 7ML Coax ø21.3 mm/316l mm ( inch) 22) 9 R 3 A mm ( inch) 22) 9 R 3 B mm ( inch) 22) 9 R 3 C mm ( inch) 22) 9 R 3 D mm ( inch) 22) mm 9 R 3 F ( inch) 22) Coax ø2.2 mm/316l mm ( inch) 22) 9 R 3 G mm ( inch) 22) 9 R 3 H mm ( inch) 22) 9 R 3 J mm ( inch) 22) 9 R 3 K mm ( inch) 22) 9 R 3 L mm ( inch) 22) 9 R 3 M Order code Further designs (mandatory) Please add "-Z" to and specify Order code(s). Supplementary electronics Without 13) A00 Additional current output ma 1)39) A01 Dimensions centering weight (diameter/height) Without B00 ø0/30 mm B01 ø5/30 mm (for 2 inch tubes) B02 ø75/30 mm (for 3 inch tubes) B03 ø95/30 mm (for inch tubes) B0 ø1.57/1.18 inch (for 2 inch schedule 160) B05 ø1.77/1.18 inch (for 2 inch schedule 0/80) B06 ø2.95/1.18 inch (for 3 inch schedule 10/0) B07 ø3.7/1.18 inch (for inch schedule 80) B08 Rod mounted Without Rod, applicable for coax or cable probe C00 types only 18) Mounted C01 Not mounted C02 Local display interface Without 13) E00 Mounted E01 Laterally mounted 1) E02 Language of display German L00 English L01 French L02 Dutch L03 Italian L0 Spanish L05 Portuguese L06 Russian L07 Chinese L08 Japanese L09 Operating instructions German M00 English M01 French M02 Spanish M03 Guided wave radar transmitters SITRANS LG series Order code Further designs (optional) Please add "-Z" to and specify Order code(s). Enter the total insertion length in plain text description Y01 Enter the total length of rigid part Y02 Cleaning included certificate: oil, grease and silicone free W01 Identification Label (measurement loop) stainless Y17 steel Identification Label (measurement loop) Foil Y Inspection Certificate for material (EN 1020 D07 NACE MR 0175) 30) 3.1-Inspection Certificate for instrument with test C25 data (EN 1020) 30) 2.2-Factory certificate for material (EN 1020) 30) C15 Quality and test plan 30) C26 Dye penetration test certificate/instrument 30) C13 X-ray test certificate/instrument 30) C1 Positive material identification test certificate/ C16 instrument 30) Roughness test certificate/instrument 30) C18 Pressure test certificate/instrument 30) C31 Helium leak test certificate/instrument 30) C32 Ferrite measuring accuracy to DIN C60 certificate/instrument 30) Pressure test according to Norsok certificate/ C61 instrument 30) 5 point calibration certificate certificate/ C62 instrument 30)1) Additional Operating Instructions German 20 ma/hart - two-wire PBD: ma/hart - two-wire coax probe PBD: ma/hart - four-wire PBD: ma/hart - four-wire coax probe PBD: Modbus PBD: Modbus- coax probe PBD: PROFIBUS PA PBD: PROFIBUS PA - coax probe PBD: Note: Operating instructions should be ordered as a separate line on the order. This device is shipped with the Siemens Milltronics manual DVD containing the operating instructions library. English 20 ma/hart - two-wire PBD: ma/hart - two-wire Coax probe PBD: ma/hart - four-wire PBD: ma/hart - four-wire Coax probe PBD: Modbus PBD: Modbus - coax probe PBD: PROFIBUS PA PBD: PROFIBUS PA - coax probe PBD: Note: Operating instructions should be ordered as a separate line on the order. This device is shipped with the Siemens Milltronics manual DVD containing the operating instructions library. Siemens FI 01 June 2015 /297

298 Guided wave radar transmitters SITRANS LG series French 20 ma/hart - two-wire PBD: ma/hart - two-wire Coax probe PBD: ma/hart - four-wire PBD: ma/hart - four-wire Coax probe PBD: Modbus PBD: Modbus- coax probe PBD: PROFIBUS PA PBD: PROFIBUS PA - coax probe PBD: Note: Operating instructions should be ordered as a separate line on the order. This device is shipped with the Siemens Milltronics manual DVD containing the operating instructions library. Spanish 20 ma/hart - two-wire PBD: ma/hart - two-wire Coax probe PBD: ma/hart - four-wire PBD: ma/hart - four-wire Coax probe PBD: Modbus PBD: Modbus- Coax probe PBD: PROFIBUS PA PBD: PROFIBUS PA - coax probe PBD: Note: Operating instructions should be ordered as a separate line on the order. This device is shipped with the Siemens Milltronics manual DVD containing the operating instructions library. Accessories SITRANS LG, GWR sensor Display Module A5E3139 SITRANS LG, USB communicator A5E SITRANS RD100, loop powered display - 7ML see Chapter 7 SITRANS RD200, universal input display with 7ML Modbus conversion - see Chapter 7 SITRANS RD300, dual line display with totalizer 7ML and linearization curve and Modbus conversion - see Chapter 7 SITRANS RD500 web, universal remote monitoring 7ML solution for instrumentation - see Chapter 7 For applicable back up point level switch - see point level measurement section 13) Available only with Housing/Protection cable options E,F, Q, R, T (double chamber options only) 1) Available only with Housing/Protection cable options C, D, L, M 15) Available with Supplementary electronic option A00 and Local display interface options E00, E01 16) Available with Supplementary electronic option A01 and Approval options 0A,0E, and 0P 17) Not Available with Approval options 0B... 0H 0P, 0Q,1B, and 1F (not available with Intrinsically Safe and shipping approvals) 19) Not available with Length options 3,, 5, R2C and R2D 20 ) Available only with Seal options C, E, F, J, M, N and Q [second line of defense (with glass seal) for all explosion proof options] 21) Available with Local display interface options E00 and E01 22) Not available with Y02 23) Available with Housing/Protection options C, D, E, F, L, M, Q, R (dust approvals) 2) SIL electronics option 2 available with Approval options 0A, 0E, 0G, 0H, 0L, 0M, 0N, 0P, 0U, 0Q, 0T, 1A, 1B, 1D, 1E, 1F and 1H 25) Available with Process Fitting/Material options 0, 05, 08, 10, ) Not available with Process fitting /Material options 0, 05, 08, 10, 13, and 1 27) Not available with Process Fitting/Material options 00 and 01 28) Available with Housing/Protection/Cable options A, B, C, D, E, F, L, M, R, S, T, and U 29) Available with Electronic option 0 only 30) Listed Certificates are not available with all configurations, please contact factory for more information 31) Not available with Process fitting/material options 02, 03, 06, 07, 11, and 12 or threaded options below PN ) Available with supplementary electronic option A00, SIL electronics 33) Available with Approvals options 0A,0J,0K,0R,0S,1A,1C,1E,and 1G 3) Available with housings/protection/cable options E,F,L,M and P 35) Available with supplementary electronic option A00 36) Available with Local display interface options E00, E01 37) Not available with version/material option K 38) Not available with Seal/Process temperature options A, G, K and Q 39) Not available with Local display interface option E02 0) Available with Housing/protection options D, F, M, R (dust approvals) 1) Available with Version/Material A, B, C, D, E and F 2) Only available with Seal/Process temperature N Note: Please consult manual for further details. 1) Available with Housing/Protection cable options E, F, Q, and R only 2) Not available with Process fitting/material options 0, 05, 08, 10, 13, and 1 3) Available only with Process Fitting/Material options , 11, 12, and (Not available with threaded connections less than 1.5 inch and flanges < DN 50/2 inch) ) Available with Seal option N only 5) Not available with Process fitting/material options , 11, 12, and (Not available with threaded connections less than 1.5 inch and flanges < DN 50/2 inch) 6) Available only with Process fitting/material options 00 and 01 (options with max temp of 80 C (176 F) only available with PN 6 rated threaded connections) 7) Available with Version/Material option J only 8) Available only with the same diameter probe lengths 9) Available with Rod mounted option C00 only (Coax and cable version only) 10) Available with Rod mounted options C01, C02 only (rod versions only) 11) Available only with Centering weight option B00 (no centering weight option) 12) Available with Centering weight options B01... B08 only /298 Siemens FI 01 June 2015

299 .E SITRANS LG260 A guided wave radar sensor for level measurement of solids. Click on the for the online configuration in the PIA Life Cycle Portal. Approvals Ordinary location CE )12) Shipping approval 9)10) ATEX II 1G, 1/2G, 2G Ex ia IIC T6 )12) ATEX II 1G, 1/2G, 2G Ex ia IIC T6 + shipping approval 9) ATEX II 1G,1/2G 2G Ex ia IIC + ATEX II 1D, 1/2D, 1/3D, 2D, Ex t IIIC IP66 T 8)10)12)21) ATEX II 1/2G, 2G Ex d ia IIC T6 1)7)12) ATEX II 1/2G, 2G Ex d ia IIC + shipping approval 1)7)9)10) ATEX II 1/2G, 2G Ex d IIC + ATEX II 1D, 1/2D, 1/3D, 2D, Ex t IIIC IP66 7)8)12)21) ATEX II 1D, 1/2D, 1/3D, 2D, Ex t IIIC IP66 11)12) ATEX II 1/2G, 2G Ex d IIC + shipping approval 9)10)11) ATEX II 1/2G,2G Ex d IIC + II 1D, 1/2D, 1/3D, 2D IP66 8)11)12)21) ATEX II 1D, 1/2D, 2D IP6x T 8)11)12)21) IEC Ex ia IIC T6 )12) IEC Ex ia IIC T6 + IEC IP6x T td 8)11)12)21) IEC Ex d ia IIC T6 1)7)12) IEC Ex d ia IIC T6 + IEC IP6x T td 7)8)12)21) Order Code 7ML A 0 B 0 E 0 G 0 H 0 J 0 L 0 M 0 N 0 Q 0 R 0 S 0 T 0 U 1 A 1 B IEC Ex d IIC T6 11)12) 1 C IEC Ex d IIC T6 + IEC IP6x T td 8)11)12)21) 1 D FM (NI) Class I, Div. 2, Groups A, B, C, D 12) 1 F FM (NI) Class I, Div. 2, Groups A, B, C, D + 1 G shipping approval 9)10) FM (IS) Class I, II, III, Div. 1, Groups A, B, C, 1 H D, E, F 12) FM (IS) Class I, II, III, Div. 1, Groups A, B, C, D, E, F, G + shipping approval 9)10) 1 J FM (XP-IS) Class I, II, III, Div. 1, Groups A, B, 1 K C, D, E, F, G 1)7)12) FM (XP-IS) Class I, II, III, Div. 1, Groups A, 1 L B, C, D, E, F, G + shipping approval 1)7)9)10) FM (XP) Class I, Div. 1, Groups A, B, C, D 11)12) 1 M CSA (NI) Class I, Div. 2,Groups A, B, C, D; 1 N (DIP) Class II, III, Div. 1, Groups E, F, G 8)12) CSA (IS) Class I, II, III, Div. 1, Groups A, B, 1 P C, D, E, F, G 12) CSA (XP-IS) Class I, II, III, Div. 1, Groups A, B, C, D, E, F, G 1)7)12) 1 Q CSA (XP) Class I, II, III, Div. 1, Groups A, B, 1 R C, D, E, F, G 11)12) Probe version/material Probe exchangeable cable ø mm A (0.16 inch) with gravity weight/316 Probe exchangeable cable B ø 6 mm (0.2 inch) with gravity weight/316 2) Probe exchangeable rod ø E 16 mm (0.63 inch) / 316L 2)6) Process fitting/material Thread G 3/" (DIN 3852-A) PN 0/316L 0 0 Thread 3/" NPT (ASME B1.20.1) PN 0/316L 0 1 Thread G 1" (DIN 3852-A) PN 0/316L 0 2 Thread 1" NPT (ASME B1.20.1) PN 0/316L 0 3 Thread G 1 1/2" (DIN 3852-A) PN 0/316L 0 Thread 1 1/2" NPT (ASME B1.20.1) PN 0/316L 0 5 Guided wave radar transmitters SITRANS LG series Order Code SITRANS LG260 7ML5882- A guided wave radar sensor for level measurement of solids Thread G 2" (DIN 3852-A) PN 0/316L 0 6 Flange DN 50 PN 0 Form C, DIN 2501/316L 1 0 Flange DN 80 PN 0 Form C, DIN 2501/316L 1 2 Flange DN 100 PN 16 Form C, DIN 2501/316L 1 3 Flange DN 100 PN 0 Form C, DIN 2501/316L 1 Flange DN 150 PN 16 Form C, DIN 2501/316L 1 5 Flange DN 50 PN 0 EN Form B1/316L 1 6 Flange DN 80 PN 0 EN Form B1/316L 1 7 Flange DN 100 PN16 EN Form B1/316L 1 8 Flange 2" 150 lb RF, ANSI B16.5/316L 3 0 Flange 2" 300 lb RF, ANSI B16.5/316L 3 2 Flange 3" 150 lb RF, ANSI B16.5/316L 3 3 Flange 3" 300 lb RF, ANSI B16.5/316L 3 Flange " 150 lb RF, ANSI B16.5/316L 3 5 Flange " 300 lb RF, ANSI B16.5/316L 3 6 Flange 6" 150 lb RF, ANSI B16.5/316L 3 7 Electronics Two-wire... 20mA/HART 0 Four-wire Modbus 16)17)18)19) 1 Two-wire...20mA/HART with SIL 2 qualification 1)15) Four-wire...20mA/HART; V AC; 50/ 3 60Hz 1)3)5) Four-wire...20mA/HART; V DC; V AC 1)3)5) PROFIBUS PA 5 Seal/Process temperature FKM (SHS FPM 70C3 GLT)/ C A ( F) FKM (SHS FPM 70C3 GLT)/ C B ( F) FFKM (Kalrez 6375)/ C C ( F) EPDM (A+P 75.5/KW75F)/ C D ( F) EPDM (A+P 75.5/KW75F)/ C E ( F) Housing/Protection/Cable Plastic IP66/IP67 M20x1.5/blind stopper A Plastic IP66/IP67 1/2" NPT/blind stopper B Plastic 2-chamber/IP66/IP67/M20x1.5/blind C stopper Plastic 2-chamber/IP66/IP67 /1/2" NPT/blind D stopper Aluminium/IP66/IP68 (0.2 bar) M20x1.5/blind E stopper Aluminium/IP66/IP68 (0.2 bar) 1/2" NPT/blind F stopper Aluminium double chamber/ip66/ip68 G (0.2 bar) M20x1.5/blind stopper Aluminium double chamber/ip66/ip68 H (0.2 bar) 1/2" NPT/blind stopper Stainless Steel (precision casting) 316L/IP66/ J IP68 (0.2 bar) M20x1.5/blind stopper Stainless steel (precision casting) 316L/IP66/ K IP68 (0.2 bar) 1/2" NPT/blind stopper Stainless steel (electropolished) 316L/IP66/ L IP68 (0.2 bar) M20x1.5/blind stopper Stainless steel (electropolished) 316L/IP66/ M IP68 (0.2 bar) 1/2" NPT/blind stopper Stainless steel double chamber/ip66/ip68 (0.2 bar) M20x1.5/blind stopper N Siemens FI 01 June 2015 /299

300 Guided wave radar transmitters SITRANS LG series Order Code SITRANS LG260 7ML5882- A guided wave radar sensor for level measurement of solids Stainless steel double chamber/ip66/ip68 P (0.2 bar) 1/2" NPT/blind stopper Aluminium/IP66/IP68 (0.2 bar) M20x1.5/ Q cable gland stainless steel Aluminium double chamber/ip66/ip68 R (0.2 bar) M20x1.5/cable gland stainless steel Stainless steel (precision casting) 316L/ S IP66/IP68 (0.2 bar) M20x1.5/cable gland stainless steel Stainless steel (electropolished) 316L/IP66/ T IP68 (0.2 bar) M20x1.5/cable gland stainless steel Aluminium single chamber/ip66/ip68 W (0.2 bar) M20x1.5/cable gland brass nickelplated Aluminium double chamber/ip66/ip68 X (0.2 bar) M20x1.5/cable gland brass nickelplated Stainless steel single chamber (precision Y casting)/ip66/ip68 (0.2 bar) M20x1.5/cable gland brass nickel-plated Lengths Rod ø16 mm/316l 500 mm (19.69 inch) mm ( inch) mm ( inch) mm ( inch) mm ( inch) mm ( inch) mm ( inch) 6 Cable lengths ø2 or mm/ mm ( inch) 9 R 2 E mm ( inch) 9 R 2 F mm ( inch) 9 R 2 G mm ( inch) 9 R 2 H mm ( inch) 9 R 2 J mm ( inch) 9 R 2 K mm 9 R 2 L ( inch) mm 9 R 2 M ( inch) mm 9 R 2 N ( inch) mm 9 R 2 P ( inch) mm 9 R 2 Q ( inch) mm 9 R 2 R ( inch) mm ( inch) 9 R 2 S Order Code SITRANS LG260 7ML5882- A guided wave radar sensor for level measurement of solids Cable lengths ø6 mm/316l 500 mm (19.69 inch) 9 R A mm ( inch) 9 R B mm ( inch) 9 R C mm ( inch) 9 R D mm ( inch) 9 R E mm 9 R F ( inch) mm 9 R G ( inch) mm 9 R H ( inch) mm 9 R J ( inch) mm 9 R K ( inch) mm 9 R L ( inch) mm 9 R M ( inch) mm 9 R N ( inch) mm ( inch) 9 R P Further designs (mandatory) Please add "-Z" to and specify Order code(s). Supplementary electronics Without 1) Additional current output ma 1)20) Rod mounted Without Rod, applicable for coax or cable probe types only Mounted Not mounted Local display interface Without Mounted Laterally mounted 1) Language of display German English French Dutch Italian Spanish Portuguese Russian Chinese Japanese Operating instructions German English French Spanish Order code A00 A01 C00 C01 C02 E00 E01 E02 L00 L01 L02 L03 L0 L05 L06 L07 L08 L09 M00 M01 M02 M03 /300 Siemens FI 01 June 2015

301 Order code Further designs (optional) Please add "-Z" to and specify Order code(s). Enter the total insertion length in plain text description Y01 Cleaning included certificate: oil, grease and silicone free W01 Identification Label (measurement loop) stainless Y17 steel Identification Label (measurement loop) Foil Y Inspection Certificate for material (EN 1020 D07 NACE MR 0175) 13) 3.1-Inspection Certificate for instrument with test C25 data (EN 1020) 13) 2.2-Factory certificate for material (EN 1020) 13) C15 Quality and test plan 13) C26 Dye penetration test certificate/instrument 13) C13 X-ray test certificate/instrument 13) C1 Positive material identification test certificate/ C16 instrument 13) Roughness test certificate/instrument 13) C18 Pressure test certificate/instrument 13) C31 Helium leak test certificate/instrument 13) C32 Ferrite measuring accuracy to DIN C60 certificate/instrument 13) Pressure test according to Norsok certificate/ C61 instrument 13) 5 point calibration certificate certificate/ C62 instrument 13) Operating Instructions German 20 ma/hart - two-wire PBD: ma/hart - four-wire PBD: Modbus PBD: PROFIBUS PA PBD: Note: Operating instructions should be ordered as a separate line on the order. This device is shipped with the Siemens Milltronics manual DVD containing the operating instructions library. English 20 ma/hart - two-wire PBD: ma/hart - four-wire PBD: Modbus PBD: PROFIBUS PA PBD: Note: Operating instructions should be ordered as a separate line on the order. This device is shipped with the Siemens Milltronics manual DVD containing the operating instructions library. French 20 ma/hart - two-wire PBD: ma/hart - four-wire PBD: Modbus PBD: PROFIBUS PA PBD: Note: Operating instructions should be ordered as a separate line on the order. This device is shipped with the Siemens Milltronics manual DVD containing the operating instructions library. Guided wave radar transmitters SITRANS LG series Spanish 20 ma/hart - two-wire PBD: ma/hart - four-wire PBD: Modbus PBD: PROFIBUS PA PBD: Note: Operating instructions should be ordered as a separate line on the order. This device is shipped with the Siemens Milltronics manual DVD containing the operating instructions library. Accessories SITRANS LG, GWR sensor Display Module A5E3139 SITRANS LG, USB communicator A5E SITRANS RD100, loop powered display - 7ML see Chapter 7 SITRANS RD200, universal input display with 7ML Modbus conversion - see Chapter 7 SITRANS RD300, dual line display with totalizer 7ML and linearization curve and Modbus conversion - see Chapter 7 SITRANS RD500 web, universal remote monitoring 7ML solution for instrumentation - see Chapter 7 For applicable back up point level switch - see point level measurement section 1) Available only with Housing/Protection/Cable Options G, H, N, P 2) Not available with Process/Fitting/Material options 00, 01, 02, and 03 3) Available with Supplementary electronic option A00 and Local display interface options E00, E01 ) Available with Supplementary electronic option A01 5) Not Available with Approval options 0B... 0H 0L, 0Q, 1B, 1F, 1G, 1J, 1L (not available with Intrinsically Safe and shipping approvals) 6) Available with Rod Mounted options C01 and C02 7) Available with Local display interface options E00 and E01 8) Available with Housing Protection options E, F, G, H, J, K, N, P 9) Not available with Housing/Protection/Cable options L, M, and T 10) Available with Electronic option 0 only 11) Available with Seal/Process temperature option C only 12) Available with Version/Material option E only 13) Listed Certificates are not available with all configurations, please contact factory for more information 1) SIL electronics option 2 available with Approval options 0A, 0E, 0G, 0H, 0N, 0Q, 0R, 0S, 0T, 0U, 1C, 1D, 1F, 1H, 1M, 1N, 1P, and 1R 15) Available with supplementary electronic option A00, SIL electronics 16) Available with Approvals options 0A, 0J, 0K, 0R, 0S,1A,1C,1E and 1G 17) Available with housings/protection/cable options E, F, L, M and P 18) Available with supplementary electronic option A00 19) Available with Local display interface options E00, E01 20) Not available with Local display interface option E02 21) Available with Housing Protection F, H, P and K Note: Please consult manual for further details. Siemens FI 01 June 2015 /301

302 Guided wave radar transmitters SITRANS LG series SITRANS LG270 A guided wave radar sensor for continuous level and interface measurement of liquids in aggressive applications Click on the for the online configuration in the PIA Life Cycle Portal. Approvals Ordinary location CE 3) Shipping approval 17)18)19) ATEX II 1G, 1/2G, 2G Ex ia IIC T6 3) ATEX II 1G, 1/2G, 2G Ex ia IIC T6 + shipping approval 17)18)19) ATEX II 1G,1/2G 2G Ex ia IIC + ATEX II 1D, 1/2D, 2D IP6x 16)28) ATEX II 1/2G, 2G Ex d ia IIC T6 1)10)1) ATEX II 1/2G, 2G Ex d ia IIC + ship 1)10)1)17)18)19) ATEX II 1/2G, 2G Ex d ia IIC + ATEX II 1/2D, 2D IP6x 10)1)16)28) ATEX II 1/2G, 2G Ex d IIC T6 11) ATEX II 1/2G, 2G Ex d IIC + ship approval 17)18)19) ATEX II 1/2G, 2G Ex d IIC + ATEX II 1/2D, 2D IP6x 11)16)28) ATEX II 1D, 1/2D, 2D IP6x T 16)28) IEC Ex ia IIC T6 3) IEC Ex ia IIC T6 + IEC IP6x T td 16)28) IEC Ex d ia IIC T6 1)10)1) IEC Ex d ia IIC T6 + IEC IP6x T td 10)1)16)28) IEC Ex d IIC T6 11) IEC Ex d IIC T6 + IEC IP6x T td 11)16)28) FM (NI) Class I, Div. 2, Groups A, B, C, D Order Code 7ML A 0 B 0 E 0 G 0 H 0 J 0 L 0 M 0 N 0 Q 0 R 0 S 0 T 0 U 1 A 1 B 1 C 1 D 1 F FM (NI) Class I, Div. 2, Groups A, B, C, D + ship approval 17)18)19) 1 G FM (IS) Class I, II, III, Div. 1, Groups A, B, C, 1 H D, E, F FM (IS) Class I, II, III, Div. 1, Groups A, B, C, 1 J D, E, F, G + ship approval 17)18)19) FM (XP-IS) Class I, II, III, Div. 1, Groups A, B, C, D, E, F, G 1)10)1) 1 K FM (XP-IS) Class I, II, III, Div. 1, Groups A, B, 1 L C, D, E, F, G + shipping approval 1)10)17)18)19) FM (XP) Class I, Div. 1, Groups A, B, C, D 1 M CSA (NI) Class I, Div. 2, Groups A, B, C, D; 1 N (DIP) Class II, III, Div. 1, Groups E, F, G 16) CSA (IS) Class I, II, III, Div. 1, Groups A, B, 1 P C, D, E, F, G CSA (XP-IS) Class I, II, III, Div. 1, Groups A, 1 Q B, C, D, E, F, G 1)10)1) CSA (XP) Class I, II, III, Div. 1, Groups A, B, 1 R C, D, E, F, G 11) Version/Material Probe exchangeable cable ø 2 mm (0.08 inch) with gravity weight/316l )7) A Probe exchangeable cable ø2 mm B (0.08 inch) center weight/316l 5)7) Probe exchangeable cable ø mm C (0.16 inch) with gravity weight/316l )7) Probe exchangeable cable ø mm (0.16 inch) with center weight/316l 5)7) D Probe exchangeable rod ø 16 mm E (0.63 inch) /316L )7)9) Probe coax version ø 2.2 mm (1.66 inch) F with multiple hole/316l )7) Probe coax version ø 2.2 mm (1.66 inch); G multiple hole; reference distances/ 316L )7)13)30) Order Code SITRANS LG270 7ML5883- A guided wave radar sensor for continuous level and interface measurement of liquids in aggressive applications Process fitting/material Thread G 1 1/2" (DIN 3852-A) PN 00/316L 0 0 Thread 1 1/2" NPT (ASME B1.20.1) PN 00/ L Flange DN 50 PN 0 Form C, DIN 2501/316L 1 0 Flange DN 50 PN 0 form V13, DIN 2513/316L 1 1 Flange DN 65 PN 6 Form V13, DIN 2501/ L Flange DN 80 PN 0 Form C, DIN 2501/316L 1 3 Flange DN 80 PN 0 Form V13, DIN 2501/ 1 316L Flange DN 80 PN 100 Form L, DIN 2501/316L 1 5 Flange DN 100 PN 16 Form C, DIN 2501/316L 1 6 Flange DN 100 PN 16 Form C, DIN 2501/316L 1 7 Flange DN 100 PN 0 Form C, DIN 2501/316L 1 8 Flange DN 100 PN 0 Form V13, DIN 2513/ L Flange DN 150 PN 16 Form C, DIN 2501/316L 2 1 Flange DN 50 PN 0 EN Form B1/316L 2 2 Flange DN 100 PN 160 GOST / L Flange DN 80 PN 160 Form C, DIN 2501/316L 6 0 Flange DN 80 PN 250 Form L, DIN 2501/316L 6 1 Flange DN 50 PN 160, EN Form B1/ L Flange DN 50 PN 160, EN Form B2/ L Flange DN 50 PN 320, EN Form B1/ 6 316L Flange DN 65 PN 250, EN Form B1/ L Flange DN 100 PN 160, EN Form B2/ L Flange 2" 150 lb RF, ANSI B16.5/316L 3 0 Flange 2" 300 lb RF, ANSI B16.5/316L 3 1 Flange 2" 600 lb RF, ANSI B16.5/316L 3 2 Flange 2" lb RF, ANSI B16.5/316L 3 3 Flange 3" 150 lb RF, ANSI B16.5/316L 3 Flange 3" 300 lb RF, ANSI B16.5/316L 3 5 Flange 3" 600 lb RF, ANSI B16.5/316L 3 6 Flange 3" 900 lb RF, ANSI B16.5/316L 3 7 Flange 3" lb RF, ANSI B16.5/316L 3 8 Flange 3 1/2" 600 lb RF, ANSI B16.5/316L 0 Flange " 150 lb RF, ANSI B16.5/316L 1 Flange " 300 lb RF, ANSI B16.5/316L 2 Flange " 600 lb RF, ANSI B16.5/316L 3 Flange 6" 150 lb RF, ANSI B16.5/316L Flange 6" 300 lb RF, ANSI B16.5/316L 5 Flange 6" 600 lb RF, ANSI B16.5/316L 6 Flange 2"150 lb Fisher special return/316l 7 Flange 2" 900 lb RF, ANSI B16.5/316L 5 0 Flange 3" lb RF, ANSI B16.5/316L 5 1 Flange " 900 lb RF, ANSI B16.5/316L 5 2 Flange " lb RF, ANSI B16.5/316L 5 3 Flange " lb RJF, ANSI B16.5/316L 5 Flange " 1500 lb RJF, ASME B16.5/316L 5 5 /302 Siemens FI 01 June 2015

303 Order Code SITRANS LG270 7ML5883- A guided wave radar sensor for continuous level and interface measurement of liquids in aggressive applications Electronics Two-wire... 20mA/HART 0 Four-wire Modbus 23)2)25)26) 1 Two-wire... 20mA/HART with SIL 2 qualification 21)22) Four-wire... 20mA/HART; V AC; 3 50/60Hz 1)2)6) Four-wire... 20mA/HART; V DC; V AC 1)2)6) PROFIBUS PA 5 Seal/Second line of defense/ Process temperature Ceramic-graphite/with glass seal/ C ( F) A Ceramic-graphite /with glass seal/ B C ( F) Housing/Protection/Cable Plastic IP66/IP67 M20x1.5/blind stopper A Plastic IP66/IP67 1/2" NPT/blind stopper B Aluminium/IP66/IP68 (0.2 bar) M20x1.5/blind C stopper Aluminium/IP66/IP68 (0.2 bar) 1/2" NPT/blind D stopper Aluminium double chamber/ip66/ip68 E (0.2 bar) M20x1.5/blind stopper Aluminium double chamber/ip66/ip68 F (0.2 bar) 1/2" NPT/blind stopper Stainless steel (precision casting) 316L/IP66/ L IP68 (0.2 bar) M20x1.5/blind stopper Stainless steel (precision casting) 316L/IP66/ M IP68 (0.2 bar) 1/2" NPT/blind stopper Stainless steel (electropolished) 316L/IP66/ N IP68 (0.2 bar) M20x1.5/blind stopper Stainless steel (electropolished) 316L/IP66/ P IP68 (0.2 bar) 1/2" NPT/blind stopper Stainless steel double chamber/ip66/ip68 Q (0.2 bar) M20x1.5/blind stopper Stainless steel double chamber/ip66/ip68 R (0.2 bar) 1/2" NPT/blind stopper Aluminium/IP66/IP68 (0.2 bar) M20x1.5/ S cable gland stainless steel Aluminium double chamber/ip66/ip68 T (0.2 bar) M20x1.5/cable gland stainless steel Stainless steel (precision casting) 316L/IP66/ U IP68 (0.2 bar) M20x1.5/cable gland stainless steel Stainless steel (electropolished) 316L/IP66/ V IP68 (0.2 bar) M20x1.5/cable gland stainless steel Aluminium single chamber / IP66/IP68 W (0.2 bar) M20x1.5/cable gland brass nickelplated Aluminium double chamber / IP66/IP68 X (0.2 bar) M20x1.5/cable gland brass nickelplated Stainless steel single chamber (precision casting) / IP66/IP68 (0.2 bar) M20x1.5/cable gland brass nickel-plated Y Guided wave radar transmitters SITRANS LG series Order Code SITRANS LG270 7ML5883- A guided wave radar sensor for continuous level and interface measurement of liquids in aggressive applications Lengths 300 mm (11.81 inch) 15) 500 mm (19.69 inch) 15) mm ( inch) 15) mm ( inch) 15) mm ( inch) 15) mm ( inch) 15) mm 5 ( inch) 15) mm 6 ( inch) 15) 300 mm (11.81 inch) 15) 7 Cable lengths ø2 or mm/316l mm ( inch) 9 R 2 E mm ( inch) 9 R 2 F mm ( inch) 9 R 2 G mm ( R 2 H inch) mm ( R 2 J inch) mm ( R 2 K inch) mm 9 R 2 L ( inch) mm 9 R 2 M ( inch) mm 9 R 2 N ( inch) mm 9 R 2 P ( inch) mm 9 R 2 Q ( inch) mm 9 R 2 R ( inch) mm 9 R 2 S ( inch) Coax ø2.2 mm/316l mm ( inch) 15) 9 R 3 G mm 9 R 3 H ( inch) 15)30) mm ( inch) 15) 9 R 3 J mm 9 R 3 K ( inch) 15) mm 9 R 3 L ( inch) 15) mm ( inch) 15) 9 R 3 M Siemens FI 01 June 2015 /303

304 Guided wave radar transmitters SITRANS LG series Order code Further designs (mandatory) Please add "-Z" to and specify Order code(s). Supplementary electronics Without A00 Additional current output ma 1)27) A01 Dimensions centering weight (diameter/height) Without B00 ø0/30 mm B01 ø5/30 mm (for 2 inch tubes) B02 ø75/30 mm (for 3 inch tubes) B03 ø95/30 mm (for inch tubes) B0 ø1.57/1.18 inch (for 2 inch schedule 160) B05 ø1.77/ 1.18 inch (for 2 inch schedule 0/80) B06 ø2.95/1.18 inch (for 3 inch schedule 10/0) B07 ø3.7/ 1.18 inch (for inch schedule 80) B08 Rod mounted Without Rod, applicable for coax or cable probe C00 types only 8) Mounted C01 Not mounted C02 Local display interface Without E00 Mounted E01 Laterally mounted 1) E02 Language of display German L00 English L01 French L02 Dutch L03 Italian L0 Spanish L05 Portuguese L06 Russian L07 Chinese L08 Japanese L09 Operating instructions German M00 English M01 French M02 Spanish M03 Russian L07 Chinese L08 Japanese L09 Order code Further designs (optional) Please add "-Z" to and specify Order code(s). Enter the total insertion length in plain text description Y01 Enter the total length of rigid part [to a maximum of Y mm ( inch) (cable version only)] Cleaning included certificate: oil, grease and silicone free W01 Identification Label (measurement loop) stainless Y17 steel Identification Label (measurement loop) Foil Y Inspection Certificate for material (EN 1020 D07 NACE MR 0175) 20) 3.1-Inspection Certificate for instrument with test C25 data (EN 1020) 20) 2.2-Factory certificate for material (EN 1020) 20) C15 Quality and test plan 20) C26 Dye penetration test certificate/instrument 20) C13 X-ray test certificate/instrument 20) C1 Positive material identification test certificate/ C16 instrument 20) Roughness test certificate/instrument 20) C18 Pressure test certificate/instrument 20) C31 Helium leak test certificate/instrument 20) C32 Ferrite measuring accuracy to DIN C60 certificate/instrument 20) Pressure test according to Norsok certificate/ C61 instrument 20) 5 point calibration certificate certificate/ C62 instrument 20)29) Additional Operating Instructions German 20 ma/hart - two-wire PBD: ma/hart - two-wire coax probe PBD: ma/hart - four-wire PBD: ma/hart - four-wire coax probe PBD: Modbus PBD: Modbus, Coax probe PBD: PROFIBUS PA PBD: PROFIBUS PA, Coax probe PBD: Note: Operating instructions should be ordered as a separate line on the order. This device is shipped with the Siemens Milltronics manual DVD containing the operating instructions library. English 20 ma/hart - two-wire PBD: ma/hart - two-wire coax probe PBD: ma/hart - four-wire PBD: ma/hart - four-wire coax probe PBD: Modbus PBD: Modbus, Coax probe PBD: PROFIBUS PA PBD: PROFIBUS PA, Coax probe PBD: Note: Operating instructions should be ordered as a separate line on the order. This device is shipped with the Siemens Milltronics manual DVD containing the operating instructions library. /30 Siemens FI 01 June 2015

305 French 20 ma/hart - two-wire PBD: ma/hart - two-wire coax probe PBD: ma/hart - four-wire PBD: ma/hart - four-wire coax probe PBD: Modbus PBD: Modbus, Coax probe PBD: PROFIBUS PA PBD: PROFIBUS PA, Coax probe PBD: Note: Operating instructions should be ordered as a separate line on the order. This device is shipped with the Siemens Milltronics manual DVD containing the operating instructions library. Spanish 20 ma/hart - two-wire PBD: ma/hart - two-wire coax probe PBD: ma/hart - four-wire PBD: ma/hart - four-wire coax probe PBD: Modbus PBD: Modbus, Coax probe PBD: PROFIBUS PA PBD: PROFIBUS PA, Coax probe PBD: Note: Operating instructions should be ordered as a separate line on the order. This device is shipped with the Siemens Milltronics manual DVD containing the operating instructions library. Accessories SITRANS LG, GWR sensor Display Module A5E3139 SITRANS LG, USB communicator A5E SITRANS RD100, loop powered display - 7ML see Chapter 7 SITRANS RD200, universal input display with 7ML Modbus conversion - see Chapter 7 SITRANS RD300, dual line display with totalizer 7ML and linearization curve and Modbus conversion - see Chapter 7 SITRANS RD500 web, universal remote monitoring 7ML solution for instrumentation - see Chapter 7 For applicable back up point level switch - see point level measurement section 1) Available with Housing/Protection/Cable options E, F, Q, R, and T 2) Available with Supplementary electronic option A00 and Local display interface options E00, E01 3) Available with Supplementary electronics A01 ) Available with Centering weight option B00 only 5) Available with Centering weight options B01... B08 only 6) Available with Approval options 0A, 0B, 0J, 0K, 0N, 0R, OS,1A, 1C, 1E, 1F, and 1G 7) Available only with the same diameter probe lengths 8) Available with Version/Material options A, B, C, D, F, G 9) 10) Available with Rod Mounted options C01 and C02 11) Available with Local display interface options E00 and E01 Available with Housing/Protection Cable options C, D, L, M only 12) 13) Version/Material Hastelloy C22, temperature is limited to 00 C (752 F) 1) Minimum probe length (Y01) is mm (9 inch) Available with Housing/Protection Cable options E, F, Q, and R 15) 16) Not available with Y02 17) Available with Housing protection options C, D, E, F, L, M, Q, and R Not available with Housing/Protection/Cable options N, P, and V 18) 19) Available with Electronic option 0 only 20) Not available with Version/Material options E, F, and G Listed Certificates are not available with all configurations, please contact factory for more information 21) SIL electronics option 2 available with Approval options 0A, 0E, 0G, 0H, 0N, 0Q, 0R, 0S, 0T, 0U, 1C, 1D, 1F, 1H, 1M, 1N, 1P, and 1R 22) Available with Supplementary electronic option A00, SIL electronics Guided wave radar transmitters SITRANS LG series 23) Available with Approval options 0A, 0H, 0K, 0R, 0S, 0U, 1A, 1C, 1D, 1E, 1F, 1H, 1N, 1P, and 1R 2) Available with housings/protection/cable options E, F, L, M and P 25) Available with supplementary electronic option A00 26) Available with Local display interface options E00, E01 27) Not available with Local display interface option E02 28) Available with Housing protection options D, F, M, and R 29) Available with Version/Material A, B, C, D, and E 30) Accuracy is application dependent, please consult factory Note: Please consult manual for further details. Siemens FI 01 June 2015 /305

306 Guided wave radar transmitters SITRANS LG series SITRANS LG Replacement Probes Click on the for the online configuration in the PIA Life Cycle Portal. Instrument LG20 )5) 0 LG250 6) 1 LG260 7) 2 LG270 9)10) 3 Probe Type Exchangeable cable ø 2 mm with gravity weight/316 1) A A Exchangeable cable ø2 mm center weight/ A C 316 2) Exchangeable cable ø mm without weight/ 316 1) A D Exchangeable cable ø mm with gravity weight/316 1) A E Exchangeable cable ø mm with center A G weight/316 2) Exchangeable cable ø 6 mm with gravity A H weight/316 1)8) Exchangeable rod ø8 mm / 316L 1) A P Exchangeable rod ø 8 mm/1.35 (acc. to A Q Basle Standard) 1) Exchangeable rod ø12 mm / 316L 1) A U Exchangeable rod ø16 mm / 316L 1) AW 7ML Process fitting Thread to 1 1/2 inch 0 Thread to 2 inch 1 Flange less than DN 50 or 2 inch 2 Flange greater or equal to DN 50 or 2 inch or 3 hygienic fitting (not for safety in gold 25 x 6 mm) Dimension centering weight Without 0 ø0 mm/ 30 mm 1 ø5 mm/ 30 mm (for 2 inch tubes) 2 ø75 mm/ 30 mm (for 3 inch tubes) 3 ø95 mm/ 30 mm (for inch tubes) ø1.57 inch/ 1.18 inch 5 (for 2 inch Schedule 160) ø1.77 inch/ 1.18 inch 6 (for 2 inch Schedule 0/80) ø2.95 inch/ 1.18 inch 7 (for 3 inch Schedule 10/0) ø3.7 inch/ 1.18 inch 8 (for inch Schedule 80) Certificates Without Material certificate Material certificate 2 Lengths Rod ø8 mm mm ( inch) A A mm ( inch) A B mm ( inch) A C mm ( inch) A D mm ( inch) A E mm ( inch) A F SITRANS LG Replacement Probes 7ML Rod ø12 mm mm ( inch) A G mm ( inch) A H mm ( inch) A J mm ( inch) A K mm ( inch) A L mm ( inch) A M Rod ø16 mm mm ( inch) A N mm ( inch) A P mm ( inch) A Q mm ( inch) A R mm ( inch) A S mm ( inch) A T Cable Lengths ø2mm and mm/ mm ( inch) A U mm ( inch) A V mm ( inch) AW mm ( inch) A X mm ( inch) A Y mm ( inch) B A mm B B ( inch) mm B C ( inch) mm B D ( inch) mm B E ( inch) mm B F ( inch) mm B G ( inch) mm B H ( inch) mm B J ( inch) mm B K ( inch) mm B L ( inch) /306 Siemens FI 01 June 2015

307 Guided wave radar transmitters SITRANS LG series SITRANS LG Replacement Probes Cable Lengths ø6mm/316 Further designs Please add "-Z" to and specify Order code(s). Enter the total insertion length in plain text description Enter the total length of rigid part (cable version only) 7ML mm ( inch) B M mm ( inch) B N mm ( inch) B P mm ( inch) B Q mm ( inch) B R mm ( inch) B S mm B T ( inch) mm B U ( inch) mm B V ( inch) mm BW ( inch) mm B X ( inch) mm B Y ( inch) mm C A ( inch) mm C B ( inch) mm C C ( inch) mm C D ( inch) Order code Y01 Y02 1) Available with Dimension centering weight: Without Option 0 2) Available with Dimension centering weight: Option ) All Probe types are only available with corresponding Probe lengths ) Available with Probe type Option AQ 5) Available with Process fitting option 2 and 3 6) Not available with Probe type option AQ and AW 7) Available with Probe type option AE, AH, and AW 8) Not available with Process fitting option 2 9) Available with Probe type option AA, AC, AE, AG and AW 10) Available with Process fitting 0 and 3 Siemens FI 01 June 2015 /307

308 Guided wave radar transmitters SITRANS LG series Characteristic curves SITRANS LG20, Ambient temperature/process temperature, standard version Ambient Temperature Maximum Permissible Temperature 80 C (176 F) 0 C (32 F) -20 C (-68 F) 150 C (302 F) Process Temperature -0 C (-10 F) SITRANS LG20, Ambient temperature/process temperature curve /308 Siemens FI 01 June 2015

309 Guided wave radar transmitters SITRANS LG series SITRANS LG250, Ambient temperature/process temperature, standard version Ambient Temperature Maximum Permissible Temperature 80 C (176 F) 65 C (19 F) Limited Temperature Range 0 C (32 F) -0 C (-10 F) 80 C (176 F) 130 C (266 F) 150 C (302 F) Process Temperature -0 C (-10 F) SITRANS LG250, Ambient temperature/process temperature, temperature adapter version Ambient Temperature 80 C (176 F) Maximum Permissible Temperature Limited Temperature Range 55 C (131 F) 0 C (32 F) -20 C (-68 F) 150 C (302 F) 200 C (392 F) Process Temperature -0 C (-10 F) SITRANS LG250, Ambient temperature/process temperature curves Siemens FI 01 June 2015 /309

310 Guided wave radar transmitters SITRANS LG series SITRANS LG260, Maximum tensile load with cereals and plastic granules - cable: ø mm (0.157 inch) "A" "B" A. Cereals B. Plastic granules 1. Tensile force in kn (the determined value must be multiplied with safety factor 2) 2. Cable length in m 3. Vessel diameter 12 m (39.37 ft). Vessel diameter 9 m (29.53 ft) 5. Vessel diameter 6 m (19.69 ft) 6. Vessel diameter 3 m (9.83 ft) SITRANS LG260, Maximum tensile load with sand and cement - cable: ø mm (0.157 inch) "C" "D" C. Sand D. Cement 1. Tensile force in kn (the determined value must be multiplied with safety factor 2) 2. Cable length in m 3. Vessel diameter 12 m (39.37 ft). Vessel diameter 9 m (29.53 ft) 5. Vessel diameter 6 m (19.69 ft) 6. Vessel diameter 3 m (9.83 ft) SITRANS LG260, Maximun tensile load curves /310 Siemens FI 01 June 2015

311 Guided wave radar transmitters SITRANS LG series SITRANS LG260, Ambient temperature/process temperature, standard version Cable version with ø mm (0.157 inch) Cable version, PA coated with ø 6 mm (0.236 inch) Ambient Temperature Maximum Permissible Temperature 80 C (176 F) 65 C (19 F) Limited Temperature Range 0 C (32 F) -0 C (-10 F) 130 C 150 C (266 F) (302 F) Process Temperature -0 C (-10 F) SITRANS LG260, Ambient temperature/process temperature, temperature adapter version Cable version with ø mm (0.157 inch) Cable version, PA coated with ø 6 mm (0.236 inch) Ambient Temperature 80 C (176 F) 55 C (131 F) Maximum Permissible Temperature Limited Temperature Range 0 C (32 F) -20 C (-68 F) 150 C (302 F) 200 C (392 F) Process Temperature -0 C (-10 F) SITRANS LG260, Ambient temperature/process temperature curves Siemens FI 01 June 2015 /311

312 Guided wave radar transmitters SITRANS LG series SITRANS LG260, Ambient temperature/process temperature, standard version Cable version with ø 6 mm (0.236 inch) Cable version, PA coated with ø 11 mm (0.33 inch) Ambient Temperature Maximum Permissible Temperature 80 C (176 F) 0 C (32 F) -0 C (-10 F) -0 C (-10 F) 150 C (302 F) Process Temperature SITRANS LG260, Ambient temperature/process temperature, temperature adapter version Cable version with ø 6 mm (0.236 inch) Cable version, PA coated with ø 11 mm (0.33 inch) Ambient Temperature Maximum Permissible Temperature 80 C (176 F) 65 C (19 F) Limited Temperature Range 0 C (32 F) -20 C (-68 F) 170 C (338 F) 200 C (392 F) Process Temperature -0 C (-10 F) SITRANS LG260, Ambient temperature/process temperature curves /312 Siemens FI 01 June 2015

313 Guided wave radar transmitters SITRANS LG series SITRANS LG270, Ambient temperature/process temperature ( C/ F version) Ambient Temperature 80 C (176 F) Maximum Permissible Temperature 65 C (19 F) 55 C (131 F) Limited Temperature Range -196 C -80 C (-321 F) (-112 F) 0 C (32 F) 190 C (37 F) 250 C 280 C (82 F) (536 F) Process Temperature -0 C (-10 F) SITRANS LG270, Ambient temperature/process temperature ( C/ F version) Ambient Temperature 80 C (176 F) Maximum Permissible Temperature Limited Temperature Range 35 C (95 F) -196 C -110 C (-321 F) (-230 F) 0 C (32 F) -20 C (-68 F) 220 C 50 C (28 F) (82 F) Process Temperature -0 C (-10 F) SITRANS LG270, Ambient temperature/process temperature curves Siemens FI 01 June 2015 /313

314 Guided wave radar transmitters SITRANS LG series SITRANS LG270, Process pressure/process temperature ( C/ F version) Process Pressure 00 bar (5800 psig) 350 bar (5070 psig) 300 bar (350 psig) 380 bar (5510 psig) 320 bar (60 psig) 200 bar (2900 psig) 100 bar (150 psig) -200 C -100 C (-328 F) (-18 F) 0 C 100 C 200 C 300 C 00 C 50 C (32 F) (212 F) (392 F) (572 F) (752 F) (82 F) Process Temperature SITRANS LG270, Process pressure/process temperature curve /31 Siemens FI 01 June 2015

315 Guided wave radar transmitters SITRANS LG series Dimensional drawings LG Series plastic housing 69 (2.72) Ø 77 (3.03) 86 (3.39) Ø 77 (3.03) M16x (.9) 11 (.9) M20x1.5/ ½" NPT Single chamber version M20x1.5/ ½" NPT Double chamber version LG Series aluminum housing 116 (.57) Ø 8 (3.31) 91 (3.58) Ø 8 (3.31) M16x (.72) 12 (.88) M20x1.5/ ½" NPT M20x1.5 Single chamber version M20x1.5/ ½" NPT Double chamber version LG Series stainless steel housing 59 (2.32) Ø 80 (3.15) 69 (2.72) Ø 77 (3.03) 90 (3.5) Ø 8 (3.31) M16x1.5 M20x1.5/ ½" NPT 112 (.1) M20x1.5/ ½" NPT 119 (.69) 123 (.8) Single chamber version, electropolished Single chamber version, precision casting M20x1.5/ ½" NPT Double chamber version, precision casting Note: For integrated display and adjustment module the housing is 9 (0.35) higher for all housing options SITRANS LG series, dimensions in mm (inch) Siemens FI 01 June 2015 /315

316 Guided wave radar transmitters SITRANS LG series SITRANS LG20 Cable version Ø (0.157), PFA coated Rod version Ø 10 (0.39), PFA coated 69. (2.73) 70 (2.76) 71. (2.81) 69. (2.73) 70 (2.76) 71. (2.81) Ø (0.16) ( ) Cable version with clamp Cable version with bolting ( ) Cable version with clamp Cable version with bolting 115 (.53) Ø (0.16) Autoclaved version Ø 10 (0.39) Rod version Ø 8 (0.315), polished Ø 5 (2.13) 112 (.8) 183 (7.20) Cover with groove nut 56 (2.02) Groove nut 65.3 (2.57) Process fitting Ø w Ø w ( ) ( ) DIN DN 25 DN 32 DN 0/ 1" 1½" DIN DN 50/ 2" DIN DN 65/ 3" Ø 50.5 Ø 6 Ø 91 Ø 8 (0.32) SITRANS LG20, dimensions in mm (inch) /316 Siemens FI 01 June 2015

317 6 (1.81) Up to 6 m (19.69 ft) 51 (2.01) Up to 6 m (19.69 ft) Siemens AG 2015 Guided wave radar transmitters SITRANS LG series SITRANS LG250 Cable version with gravity weight Rod version SW 36 (1.2") (G3/, 3/" NPT) SW 1 (1.61") (G1, 1" NPT) SW 6 (1.81") (G1½, 1½" NPT) Ø 2 (0.08) Ø 16 (0.63) G3/, 3/" NPT G1, 1" NPT G1½, 1½" NPT 50 (1.97) Ø 20 (0.79) Ø (0.16) Ø 16 (0.63) 22 (0.87) 100 (3.9) 6 (1.81) ( ) Ø 20 (0.79) Ø (0.16) Ø 16 (0.63) 22 (0.87) 100 (3.9) Ø 20 (0.79) 96 (3.78) ( ) Cable version with centering weight SW 36 (1.2") (G3/, 3/" NPT) SW 1 (1.61") (G1, 1" NPT) SW 6 (1.81") (G1½, 1½" NPT) Ø 2 (0.08) G3/, 3/" NPT G1, 1" NPT G1½, 1½" NPT 30 (1.18) Ø (0.16) 22 (0.87) 30 (1.18) SW 36 (1.2") (G3/, 3/" NPT) SW 1 (1.61") (G1, 1" NPT) SW 6 (1.81") (G1½, 1½" NPT) 6 (1.81) ( ) G3/, 3/" NPT G1, 1" NPT G1½, 1½" NPT 22 (0.87) Ø 8 (0.32) 6 (1.81) ( ) SW 55 (2.17) G1½, 1½" NPT Ø 12 (0.7) 30 (1.18) 51 (2.01) ( ) Ø 2 (0.079) Ø (0.157) SITRANS LG250, dimensions in mm (inch) SITRANS LG250, coax version Coaxial version ø 21.3 (0.839) Coaxial version ø 2.2 (1.661) SW 36 (1.2) (G¾, ¾" NPT) SW 1 (1.61) (G1, 1" NPT) SW 6 (1.81) (G1½, 1½" NPT) G¾, ¾" NPT, G1, 1" NPT, G1½, 1½" NPT SW 55 (2.17) G1½, 1½" NPT 22 (0.86) ø 21.3 (0.8) ø 2.2 (1.66) SITRANS LG250, dimensions in mm (inch) Siemens FI 01 June 2015 /317

318 Guided wave radar transmitters SITRANS LG series SITRANS LG260 Cable version Ø 6 (0.236)/ Ø 11 (0.33)- PA coated Cable version Ø (0.157)/ Ø 6 (0.236)- PA coated Rod version Ø 16 (0.63) SW (3.15) G1½ SW G 3/ 6 (1.81) Joint cable 30 (0.2) SW G1½ 80 (3.15) Joint cable Ø (0.16) 22 (0.87) ( ) Ø 6 (0.2) Ø 6 (0.2) ( ) Ø 11 (0.3) Joint rod 30 (0.2) ( ) Ø 22 (0.79) Ø (0.157) 150 (5.91) Ø 11 (0.33) 150 (5.91) Ø 16 (0.63) SITRANS LG260, dimensions in mm (inch) /318 Siemens FI 01 June 2015

319 Guided wave radar transmitters SITRANS LG series SITRANS LG270 Cable version with gravity weight Cable version with centering weight Max. height of the vessel insulation 237 (9.33) SW 60 (2.36) G1½ 1½" NPT 312 (12.28) Max. height of the vessel insulation 237 (9.33) SW 60 (2.36) G1½ 1½" NPT 312 (12.28) Ø 16 (0.63) Ø (0.16) 100 (3.9) Ø 20 (0.79) ( ) Ø 2 (0.08) Ø 16 (0.63) 50 (1.97) Ø 20 (0.79) Ø 16 (0.63) Ø (0.16) 100 (3.9) 35 (1.38) Ø 20 (0.79) ( ) Ø 2 / Ø (0.08)(0.16) 30 (1.18) 5 (1.77) ( ) Ø 2 (0.08)/ Ø (0.16) 30 (1.18) Ø 2 (0.08)/ Ø (0.16) 30 (1.18) 35 (1.38) ( ) Rod version Max. height of the vessel insulation 237 (9.33) SW 60 (2.36) 312 (12.28) G1½ 1½" NPT 5 (1.77) 35 (1.38) ( ) ( ) Ø 16 (0.63) Ø 16 (0.63) SITRANS LG270, dimensions in mm (inch) Siemens FI 01 June 2015 /319

320 Up to 6 m (19.69 ft) Up to 6 m (19.69 ft) Siemens AG 2015 Guided wave radar transmitters SITRANS LG series SITRANS LG270, coax version Temperature version C ( F) Temperature version C ( F) SITRANS LG270, dimensions in mm (inch) /320 Siemens FI 01 June 2015

321 Guided wave radar transmitters SITRANS LG series Schematics 2-wire HART electronic option, electronics and connection compartment, single chamber housing Voltage supply, signal output -20mA ( (-) For display and adjustment module or interface adapter For external display and adjustment unit Ground terminal for connection of the cable screen 2-wire HART electronic option, electronics compartment, double chamber housing For display and adjustment module or interface adapter Internal connection to the connection compartment -20mA ( + ) (-) Internal connection to the plug connector for external display and adjustment unit (optional) 2-wire HART electronic option, connection compartment, Ex-d-ia double chamber housing Note: All 2-wire HART connections and electronics are also available with SIL Voltage supply, signal output -20mA ( + ) 1 2 (-) Ground terminal for connection of the cable screen SITRANS LG series, connections -wire HART electronic option, electronics compartment, double chamber housing For display and adjustment module or interface adapter -wire electronic option, connection compartment with double chamber housing with mains voltage... 20mA... 20mA ( + ) 1 2(-) ( + ) 1 2 (-) Internal connection to the connection compartment Voltage Supply PE Power Supply Active + Passive + Common IS GND Function ground with installation according to CSA Mass - output + 20 ma output (passive) + 20 ma output (active) SITRANS LG series, connections Siemens FI 01 June 2015 /321

322 Siemens AG 2015 Guided wave radar transmitters SITRANS LG series Supplementary electronics Connection compartment with low voltage...20ma I... 20mA... 20mA ( + ) 1 2 (-) ( + ) 7 8(-) II /N Power Supply Active + Passive + Common IS GND ( + ) 1 2 (-) Function ground with installation according to CSA + + Mass - output 20 ma output (passive) 20 ma output (active) 1 2 First current output (I) - Voltage supply and signal output (HART) Second current output (II) - Voltage supply and signal output (without HART) SITRANS LG series, connections Voltage supply Modbus electronic option, connection compartment power supply USB MODBUS ( ) + D0 (-) D1 IS GND USB interface Slide switch for integrated termination resistor (120 Ω) Modbus electronic option, electronics compartment, double chamber housing ma For display and adjustment module or interface adapter + 1 2(-) off on 3 5 ( ) (+) 1 2 (-) Modbus signal Voltage supply 1 1 Internal connection to the connection compartment SITRANS LG series, connection PROFIBUS electronic option, connection compartment, double chamber housing PROFIBUS electronic option, electronics compartment, double chamber housing Bus Bus (+)1 2(-) (+)1 2(-) Voltage supply, signal output For display and adjustment module or interface adapter 1 2 Internal connection to the connection compartment Contact pins for the display and adjustment module or interface adapter 3 Ground terminal for connection of the cable screen 3 Selection switch for bus address LG series, connection /322 Siemens FI 01 June 2015

323 Siemens AG 2015 Guided wave radar transmitters SITRANS LG series PROFIBUS electronic option, electronics and connection compartment, single chamber housing Bus 0 (+)1 2(-) Voltage supply, signal output For display and adjustment module or interface adapter Selection switch for bus address For external display and adjustment unit Ground terminal for connection of the cable screen LG series, connection Siemens FI 01 June 2015 /323

324 Continuous level measurement - Capacitance transmitters SITRANS LC300 Overview Configuration Installation Build up of material in active shield area does not affect switch operation. Mounting on a bypass SITRANS LC300 is an inverse frequency shift capacitance continuous level transmitter for liquids and solids applications. It is ideal for standard industrial applications in chemical, hydrocarbon processing, food and beverage, water, wastewater, and mining, aggregate, and cement industries. Benefits Active-Shield technology so measurement is unaffected by material buildup in active shield section Highly accurate and reliable PFA-lined probes Integrated local LCD display 2-wire ( to 20 ma) current loop design Current signaling according to NAMUR NE 3 Push-button calibration and programming Stilling well (ground tube) version for low dielectric media and non-metallic vessels Install probe at least 50 (2) from tank wall. Note angle of repose and adjust accordingly. Min. 50 (2) Min. 50 (2) Application SITRANS LC300 is a 2-wire level measurement instrument combining a sophisticated, yet easy-to-adjust microprocessor with field-proven probes. It is available in four versions: rod, rod with stilling well, cable with PFA insulation, and cable without PFA insulation. Materials with low or high dielectric properties are accurately measured and Active-Shield technology helps in ignoring the effects of buildup or condensation near vessel nozzle. Key Applications: conductive and non-conductive media including: liquids and solids in standard industrial processes, bulk solids applications involving dust, and chemical processes involving vapor SITRANS LC300 installation, dimensions in mm (inch) /32 Siemens FI 01 June 2015

325 Continuous level measurement - Capacitance transmitters SITRANS LC300 Technical specifications Input Measuring range Span Output Loop current pf Min. 3.3 pf Continuous signal ma/ ma according to NAMUR 3 Accuracy (transmitter) Temperature stability 0.25 % of actual capacitance value Non-linearity and repeatability < 0. % of full scale and actual measurement value Accuracy Deviation < 0.5 % of actual measurement value Rated operating conditions 1) Ambient conditions Ambient temperature C ( F) 2) Installation category I Pollution degree Ingress protection Type /NEMA /IP65 (optional IP68) Installation conditions Location Indoor/outdoor Process pressure bar g ( psi g) Process temperature ºC ( ºF) 3) Min. dielectric constant ε r 1.5 Design Material Enclosure Aluminum, epoxy-coated Probe diameter Rod version 19 mm (0.75 inch) with PFA jacket Cable version 9 mm (0.35 inch) with PFA jacket, 6 mm (0.2 inch) without PFA jacket Active shield length Rod version Threaded: 120 mm (.72 inch) Flanged: 100 mm (3.9 inch) Cable version Threaded: 125 mm (.92 inch) Flanged: 105 mm (.13 inch) Process connection of probe Threaded rod mounting Threaded cable mounting ¾",1",1¼", 1½" NPT [(Taper), ANSI/ASME B1.20.1] R ¾",1", 1½" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] G ¾",1", 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] 1½" NPT [(Taper), ANSI/ASME B1.20.1] R 1½" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] Flange mounting 1... " ASME, DN Enclosure cable inlet 2 x ½" NPT or 2 x M20x1.5 Power supply V DC any polarity, 2-wire current loop circuit User Interface Display Local LCD, digit, each and limited alpha characters Safety Measurement current signaling According to NAMUR NE 3, signal ma, fault 3.6 or 21 ma (22 ma) Certificates and approvals General CE, CSA US/C, FM, RCM Dust Ignition Proof (Intrinsically Safe probe circuit) Canada/USA FM/CSA: Class II, Div. 1, Groups E, F, G Class III T Europe ATEX 1/2 D T100 C Flame Proof (Intrinsically Safe probe circuit) Europe Explosion Proof (Intrinsically Safe probe circuit) Canada/USA Marine Overfill Protection Other ATEX II 1/2 G EEx d [ia] IIC T6... T1 ATEX II 1/2 D T100 C Class I, Div. 1, Groups A, B, C, D Class II, Div. 1, Groups E, F, G Class III T Bureau Veritas Type Approval ABS Type Approval AIB-Vincotte Pattern Approval (China) 1) When operation is in areas classified as hazardous, observe restrictions according to relevant certificate. See also Pressure/Temperature curves on page 5/16. 2) Thermal isolator is used if process connection temperature exceeds 85 C (185 F) 3) Not suitable for steam environments Design: Probe Length Sensor wetted parts Rod version Min. 300 mm (12 inch), max mm (197 inch) PFA, 316L stainless steel Stilling well version Min. 300 mm (12 inch), max mm (197 inch) PFA, 316L stainless steel Cable version Min mm (0 inch), max mm (98 inch) 316L stainless steel or 316L stainless steel with PFA insulation O-ring seal FKM or FFKM FKM or FFKM FKM or FFKM material Thermal isolator Optional Optional Optional Options N/A N/A Mounting eye for PFA insulated cable version Siemens FI 01 June 2015 /325

326 Continuous level measurement - Capacitance transmitters SITRANS LC300 SITRANS LC300, rod version An inverse frequency shift capacitance continuous level transmitter for liquids and solids applications. 7ML Click on the for the online configuration in the PIA Life Cycle Portal. Process connection Threaded, 316L stainless steel ¾" NPT [(Taper), ANSI/ASME B1.20.1] 0 A 1" NPT [(Taper), ANSI/ASME B1.20.1] 0 B 1¼" NPT [(Taper), ANSI/ASME B1.20.1] 0 C 1½" NPT [(Taper), ANSI/ASME B1.20.1] 0 D R ¾" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] 1 A R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] 1 B R 1½" [(BSPT), EN 10226/PT (JIS-T), 1 D JIS B 0203] G ¾" [(BSPP), EN ISO 228-1/PF (JIS-P), 3 A JIS B 0202] G 1" [(BSPP), EN ISO 228-1/PF (JIS-P), 3 B JIS B 0202] G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), 3 D JIS B 0202] Welded flange, 316L stainless steel, raised face 1) 1" ASME, 150 lb 5 A 1" ASME, 300 lb 5 B 1" ASME, 600 lb 5 C 1½" ASME, 150 lb 5 D 1½" ASME, 300 lb 5 E 1½" ASME, 600 lb 5 F 2" ASME, 150 lb 5 G 2" ASME, 300 lb 5 H 2" ASME, 600 lb 5 J 3" ASME, 150 lb 5 K 3" ASME, 300 lb 5 L 3" ASME, 600 lb 5 M " ASME, 150 lb 5 N " ASME, 300 lb 5 P " ASME, 600 lb 5 Q Welded flange, 316L stainless steel, Type A flat faced 1) DN 25, PN 16 6 A DN 25, PN 0 6 B DN 0, PN 16 6 C DN 0, PN 0 6 D DN 50, PN 16 6 E DN 50, PN 0 6 F DN 80, PN 16 6 G DN 80, PN 0 6 H DN 100, PN 16 6 J DN 100, PN 0 6 K Probe Length (from flange face or including process thread) Add Order code Y01 and plain text: "Insertion length... mm" mm ( inch) A mm ( inch) B mm ( inch) C mm ( inch) D mm ( inch) E Thermal isolator Without thermal isolator 0 With thermal isolator [for process connection 1 temperatures over 85 C (185 F)] SITRANS LC300, rod version 7ML5670- An inverse frequency shift capacitance continuous level transmitter for liquids and solids applications. Wetted seals FKM 0 FFKM [for process temperatures above -20 C 1 (- F)] Probe material 19 mm (0.75 inch) diameter 316L stainless steel, 0 PFA lined rod Approvals General Safety (CSA, FM, CE, RCM) A Dust Ignition Proof With IS Probe B CE, RCM, ATEX II 1/2 D T100 C Flame Proof Enclosure With IS Probe C CE, RCM, ATEX II 1/2 G EEx d [ia] IIC T6...T1, ATEX II 1/2 D T100 C Dust Ignition Proof With IS Probe D CSA/FM Class II, Div. 1, Groups E, F, G CSA/FM Class III T Explosion Proof Enclosure With IS Probe E CSA/FM Class I, Div. 1, Groups A, B, C, D CSA/FM Class II, Div. 1, Groups E, F, G CSA/FM Class III T Enclosure Aluminum epoxy coated 2 x ½" NPT via adapter - A cable inlet, IP65 Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, B IP65 Aluminum epoxy coated 2 x ½" NPT via adapter - C cable inlet, IP68 Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, D IP68 1) Flange bolting patterns and facings dimensionally correspond to the applicable ASME B16.5 or EN standard. /326 Siemens FI 01 June 2015

327 Further designs Please add "-Z" to and specify Order code(s). Insertion length, specify in plain text: Y01:... mm Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Measuring-point number/identification (max. 27 characters) specify in plain text Manufacturer's Test Certificate: M to DIN 55350, Part 18 and to ISO 9000 Inspection Certificate Type 3.1 per EN 1020 Operating Instructions English French German Spanish Multi-language Quick Start manual Note: The Operating Instructions should be ordered as a separate line item on the order. This device is shipped with the Siemens Milltronics manual DVD containing the ATEX Quick Start and Operating Instructions library. Accessories Electronic transmitter kit (includes transmitter and driver) SITRANS RD100, loop powered display - see Chapter 7 SITRANS RD200, universal input display with Modbus conversion - see Chapter 7 SITRANS RD300, dual line display with totalizer and linearization curve and Modbus conversion - see Chapter 7 SITRANS RD500 web, universal remote monitoring solution for instrumentation - see Chapter 7 For applicable back up point level switch - see point level measurement section Order code Y01 Y15 C11 C12 7ML1998-5HE03 7ML1998-5HE11 7ML1998-5HE33 7ML1998-5HE21 A5E ML1830-1KN 7ML ML ML ML Continuous level measurement - Capacitance transmitters SITRANS LC300 Siemens FI 01 June 2015 /327

328 Continuous level measurement - Capacitance transmitters SITRANS LC300 SITRANS LC300, stilling well version An inverse frequency shift capacitance continuous level transmitter for liquid applications. 7ML Click on the for the online configuration in the PIA Life Cycle Portal. Process connection Threaded, 316L stainless steel 1½" NPT [(Taper), ANSI/ASME B1.20.1] 0 D R 1½" [(BSPT), EN 10226/PT (JIS-T), 1 D JIS B 0203] G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), 3 D JIS B 0202] Welded flange, 316L stainless steel, raised face 1) 1½" ASME, 150 lb 5 D 1½" ASME, 300 lb 5 E 1½" ASME, 600 lb 5 F 2" ASME, 150 lb 5 G 2" ASME, 300 lb 5 H 2" ASME, 600 lb 5 J 3" ASME, 150 lb 5 K 3" ASME, 300 lb 5 L 3" ASME, 600 lb 5 M " ASME, 150 lb 5 N " ASME, 300 lb 5 P " ASME, 600 lb 5 Q Welded flange, 316L stainless steel, Type A flat faced 1) DN 0, PN 16 6 C DN 0, PN 0 6 D DN 50, PN 16 6 E DN 50, PN 0 6 F DN 80, PN 16 6 G DN 80, PN 0 6 H DN 100, PN 16 6 J DN 100, PN 0 6 K Probe Length (from flange face or including process thread) Add Order code Y01 and plain text: "Insertion length... mm" mm ( inch) A mm ( inch) B mm ( inch) C mm ( inch) D mm ( inch) E Thermal isolator Without thermal isolator 0 With thermal isolator [for process connection 1 temperatures over 85 C (185 F)] Wetted seals FKM 0 FFKM [for process temperatures above -20 C (- F)] 1 Probe material 35 mm (1.38 inch) diameter stilling well, 1 with 19 mm (0.75 inch) diameter 316L stainless steel, PFA lined rod with PTFE spacers Approvals General Safety (CSA, FM, CE, RCM) A Dust Ignition Proof With IS Probe B CE, RCM, ATEX II 1/2 D T100 C Flame Proof Enclosure With IS Probe C CE, RCM, ATEX II 1/2 G EEx d [ia] IIC T6... T1, ATEX II 1/2 D T100 C SITRANS LC300, stilling well version An inverse frequency shift capacitance continuous level transmitter for liquid applications. Dust Ignition Proof With IS Probe CSA/FM Class II, Div. 1, Groups E, F, G CSA/FM Class III T Explosion Proof Enclosure With IS Probe CSA/FM Class I, Div. 1, Groups A, B, C, D CSA/FM Class II, Div. 1, Groups E, F, G CSA/FM Class III T Enclosure Aluminum epoxy coated 2 x ½" NPT via adapter - cable inlet, IP65 Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 Aluminum epoxy coated 2 x ½" NPT via adapter - cable inlet, IP68 Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP68 1) Flange bolting patterns and facings dimensionally correspond to the applicable ASME B16.5 or EN standard. Further designs Please add "-Z" to and specify Order code(s). Insertion length, specify in plain text: Y01:... mm Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Measuring-point number/identification (max. 27 characters) specify in plain text Manufacturer's Test Certificate: M to DIN 55350, Part 18 and to ISO 9000 Inspection Certificate Type 3.1 per EN 1020 Operating Instructions English French German Spanish Multi-language Quick Start manual Note: The Operating Instructions should be ordered as a separate line item on the order. This device is shipped with the Siemens Milltronics manual DVD containing the ATEX Quick Start and Operating Instructions library. Accessories Electronic transmitter kit (includes transmitter and driver) SITRANS RD100, loop powered display - see Chapter 7 SITRANS RD200, universal input display with Modbus conversion - see Chapter 7 SITRANS RD300, dual line display with totalizer and linearization curve and Modbus conversion - see Chapter 7 SITRANS RD500 web, universal remote monitoring solution for instrumentation - see Chapter 7 For applicable back up point level switch - see point level measurement section 7ML Order code Y01 Y15 C11 D E A B C D C12 7ML1998-5HE03 7ML1998-5HE11 7ML1998-5HE33 7ML1998-5HE21 7ML1998-5QH81 7ML1830-1KN 7ML ML ML ML /328 Siemens FI 01 June 2015

329 Continuous level measurement - Capacitance transmitters SITRANS LC300 SITRANS LC300, cable version An inverse frequency shift capacitance continuous level transmitter for non-conductive liquids and solids applications. Click on the for the online configuration in the PIA Life Cycle Portal. Process connection Threaded, 316L stainless steel 7ML ½" NPT [(Taper), ANSI/ASME B1.20.1] 0 D R 1½" [(BSPT), EN 10226/PT (JIS-T), 1 D JIS B 0203] G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), 3 D JIS B 0202] Welded flange, 316L stainless steel, raised face 1) 1½" ASME, 150 lb 5 D 1½" ASME, 300 lb 5 E 1½" ASME, 600 lb 5 F 2" ASME, 150 lb 5 G 2" ASME, 300 lb 5 H 2" ASME, 600 lb 5 J 3" ASME, 150 lb 5 K 3" ASME, 300 lb 5 L 3" ASME, 600 lb 5 M " ASME, 150 lb 5 N " ASME, 300 lb 5 P " ASME, 600 lb 5 Q Welded flange, 316L stainless steel, Type A flat faced 1) DN 0, PN 16 6 C DN 0, PN 0 6 D DN 50, PN 16 6 E DN 50, PN 0 6 F DN 80, PN 16 6 G DN 80, PN 0 6 H DN 100, PN 16 6 J DN 100, PN 0 6 K Probe Length (from flange face or including process thread) Add Order code Y01 and plain text: "Insertion length... mm" mm ( inch) A mm ( inch) B mm ( inch) C mm ( inch) D mm ( inch) E mm ( inch) F mm ( inch) G mm ( inch) 2) H mm ( inch) 2) J mm ( inch) 2) K mm ( inch) 2) L mm ( inch) 2) M mm ( inch) 2) N Thermal isolator Without thermal isolator 0 With thermal isolator [for process connection 1 temperatures over 85 C (185 F)] Wetted seals FKM 0 FFKM [for process temperatures above 1-20 C (- F)] Probe material Bare 316L stainless steel cable and 316L stainless steel cable weight, tinned copper crimp, PTFE backing ring, PEEK isolator and PFA lined active shield 0 SITRANS LC300, cable version An inverse frequency shift capacitance continuous level transmitter for non-conductive liquids and solids applications. Approvals General Safety (CSA, FM, CE, RCM) Dust Ignition Proof With IS Probe CE, RCM, ATEX II 1/2 D T100 C Flame Proof Enclosure With IS Probe CE, RCM, ATEX II 1/2 G EEx d [ia] IIC T6...T1, ATEX II 1/2 D T100 C Dust Ignition Proof With IS Probe CSA/FM Class II, Div. 1, Groups E, F, G CSA/FM Class III T Explosion Proof Enclosure With IS Probe CSA/FM Class I, Div. 1, Groups A, B, C, D CSA/FM Class II, Div. 1, Groups E, F, G CSA/FM Class III T Enclosure Aluminum epoxy coated 2 x ½" NPT via adapter - cable inlet, IP65 Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 Aluminum epoxy coated 2 x ½" NPT via adapter - cable inlet, IP68 Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP68 7ML ) Flange bolting patterns and facings dimensionally correspond to the applicable ASME B16.5 or EN standard. 2) Cable lengths from mm ( inch) to mm (98.25 inch) can be used in non-conductive media. Contact Factory for assistance. A B C D E A B C D Siemens FI 01 June 2015 /329

330 Continuous level measurement - Capacitance transmitters SITRANS LC300 Further designs Please add "-Z" to and specify Order code(s). Insertion length, specify in plain text: Y01:... mm Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Measuring-point number/identification (max. 27 characters) specify in plain text Manufacturer's Test Certificate: M to DIN 55350, Part 18 and to ISO 9000 Inspection Certificate Type 3.1 per EN 1020 Operating Instructions English French German Spanish Multi-language Quick Start manual Note: The Operating Instructions should be ordered as a separate line item on the order. This device is shipped with the Siemens Milltronics manual DVD containing the ATEX Quick Start and Operating Instructions library. Accessories Electronic transmitter kit (includes transmitter and driver) SITRANS RD100, loop powered display - see Chapter 7 SITRANS RD200, universal input display with Modbus conversion - see Chapter 7 SITRANS RD300, dual line display with totalizer and linearization curve and Modbus conversion - see Chapter 7 SITRANS RD500 web, universal remote monitoring solution for instrumentation - see Chapter 7 For applicable back up point level switch - see point level measurement section Order code Y01 Y15 C11 C12 7ML1998-5HE03 7ML1998-5HE11 7ML1998-5HE33 7ML1998-5HE21 7ML1998-5QH81 7ML1830-1KN 7ML ML ML ML /330 Siemens FI 01 June 2015

331 Continuous level measurement - Capacitance transmitters SITRANS LC300 SITRANS LC300, PFA coated cable version An inverse frequency shift capacitance continuous level transmitter for liquids and solids applications. Click on the for the online configuration in the PIA Life Cycle Portal. Process connection Threaded, 316L stainless steel 7ML ½" NPT [(Taper), ANSI/ASME B1.20.1] 0 D R 1½" [(BSPT), EN 10226/PT (JIS-T), 1 D JIS B 0203] G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), 3 D JIS B 0202] Welded flange, 316L stainless steel, raised face 1) 1½" ASME, 150 lb 5 D 1½" ASME, 300 lb 5 E 1½" ASME, 600 lb 5 F 2" ASME, 150 lb 5 G 2" ASME, 300 lb 5 H 2" ASME, 600 lb 5 J 3" ASME, 150 lb 5 K 3" ASME, 300 lb 5 L 3" ASME, 600 lb 5 M " ASME, 150 lb 5 N " ASME, 300 lb 5 P " ASME, 600 lb 5 Q Welded flange, 316L stainless steel, Type A flat faced 1) DN 0, PN 16 6 C DN 0, PN 0 6 D DN 50, PN 16 6 E DN 50, PN 0 6 F DN 80, PN 16 6 G DN 80, PN 0 6 H DN 100, PN 16 6 J DN 100, PN 0 6 K Probe Length (from flange face or including process thread) Add Order code Y01 and plain text: "Insertion length... mm" mm ( inch) A mm ( inch) B mm ( inch) C mm ( inch) D mm ( inch) E mm ( inch) F mm ( inch) G mm ( inch) 2) H mm ( inch) 2) J mm ( inch) 2) K mm ( inch) 2) L mm ( inch) 2) M mm ( inch) 2) N Thermal isolator Without thermal isolator 0 With thermal isolator [for process connection 1 temperatures over 85 C (185 F)] Wetted seals FKM 0 FFKM [for process temperatures above -20 C 1 (- F)] SITRANS LC300, PFA coated cable version 7ML5673- An inverse frequency shift capacitance continuous level transmitter for liquids and solids applications. Probe material PFA coated cable and 316L stainless steel cable 1 weight, PEEK isolator and PFA lined active shield Approvals General Safety (CSA, FM, CE, RCM) A Dust Ignition Proof With IS Probe B CE, RCM, ATEX II 1/2 D T100 C Flame Proof Enclosure With IS Probe C CE, RCM, ATEX II 1/2 G EEx d [ia] IIC T6...T1, ATEX II 1/2 D T100 C Dust Ignition Proof With IS Probe D CSA/FM Class II, Div. 1, Groups E, F, G CSA/FM Class III T Explosion Proof Enclosure With IS Probe E CSA/FM Class I, Div. 1, Groups A, B, C, D CSA/FM Class II, Div. 1, Groups E, F, G CSA/FM Class III T Enclosure Aluminum epoxy coated 2 x ½" NPT via adapter - A cable inlet, IP65 Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, B IP65 Aluminum epoxy coated 2 x ½" NPT via adapter - C cable inlet, IP68 Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, D IP68 Mounting eye Without Mounting eye 0 With mounting eye 1 1) Flange bolting patterns and facings dimensionally correspond to the applicable ASME B16.5 or EN standard. 2) Cable lengths from mm ( inch) to mm (98.25 inch) can be used in non-conductive media. Contact Factory for assistance. Siemens FI 01 June 2015 /331

332 Continuous level measurement - Capacitance transmitters SITRANS LC300 Further designs Please add "-Z" to and specify Order code(s). Insertion length, specify in plain text: Y01:... mm Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Measuring-point number/identification (max. 27 characters) specify in plain text Manufacturer's Test Certificate: M to DIN 55350, Part 18 and to ISO 9000 Inspection Certificate Type 3.1 per EN 1020 Operating Instructions English French German Spanish Multi-language Quick Start manual Note: The Operating Instructions should be ordered as a separate line item on the order. This device is shipped with the Siemens Milltronics manual DVD containing the ATEX Quick Start and Operating Instructions library. Accessories Electronic transmitter kit (includes transmitter and driver) SITRANS RD100, loop powered display - see Chapter 7 SITRANS RD200, universal input display with Modbus conversion - see Chapter 7 SITRANS RD300, dual line display with totalizer and linearization curve and Modbus conversion - see Chapter 7 SITRANS RD500 web, universal remote monitoring solution for instrumentation - see Chapter 7 For applicable back up point level switch - see point level measurement section Order code Y01 Y15 C11 C12 7ML1998-5HE03 7ML1998-5HE11 7ML1998-5HE33 7ML1998-5HE21 7ML1998-5QH81 7ML1830-1KN 7ML ML ML ML /332 Siemens FI 01 June 2015

333 Continuous level measurement - Capacitance transmitters SITRANS LC300 Characteristic curves Pressure/temperature curve LC300 standard, extended rod and cable probes Threaded process connections (7ML5670, 7ML5671, 7ML5672 and 7ML5673) Permitted operating pressures P 0 bar (580 psi) 30 bar (35 psi) Atmospheric -1 bar (-1.5 psi) -150 ºC (-238 ºF) -100 ºC (-18 ºF) 20 bar (290 psi) 10 bar (15 psi) -0 ºF 1 ºF (-0 ºC) (-10 ºC) -50 ºC (-58 ºF) 100 ºF (38 ºC) 200 ºF (93 ºC) 0 ºC RT 50 ºC 100 ºC (32 ºF) (122 ºF) (212 ºF) 300 ºF (19 ºC) 150 ºC (302 ºF) 00 ºF (20 ºC) 200 ºC (392 ºF) 500 ºF (260 ºC) 250 ºC (82 ºF) -29 ºC (-20 ºF) Permitted operating temperature T Example: Permitted operating pressure = 30 bar (35 psi) at 75 C SITRANS LC300 Process Pressure/Temperature derating curves (7ML5625) Siemens FI 01 June 2015 /333

334 Continuous level measurement - Capacitance transmitters SITRANS LC300 Pressure/temperature curve LC300 standard, extended rod and cable probes ASME flanged process connections (7ML5670, 7ML5671, 7ML5672 and 7ML5673) Permitted operating pressures P 90 bar (1.305 psi) 80 bar (1.160 psi) 70 bar (1.015 psi) 60 bar (870 psi) 50 bar (725 psi) ASME 600 1) 0 bar (580 psi) 30 bar (35 psi) 20 bar (290 psi) ASME 300 1) Atmospheric -1 bar (-1.5 psi) -150 ºC (-238 ºF) -100 ºC (-18 ºF) 10 bar (15 psi) -0 ºF 1 ºF (-0 ºC) (-10 ºC) -50 ºC (-58 ºF) -29 ºC (-20 ºF) 100 ºF (38 ºC) 200 ºF (93 ºC) 0 ºC RT 50 ºC 100 ºC (32 ºF) (122 ºF) (212 ºF) 300 ºF (19 ºC) 150 ºC (302 ºF) 00 ºF (20 ºC) 200 ºC (392 ºF) 500 ºF (260 ºC) 250 ºC (82 ºF) 600 ºF (315 ºC) 300 ºC (572 ºF) ASME 150 1) 700 ºF (371 ºC) 350 ºC (662 ºF) 00 ºC (752 ºF) Permitted operating temperature T 1) The curve denotes the minimum allowable flange class for the shaded area below. SITRANS LC300 Process Pressure/Temperature derating curves (7ML5626) Pressure/temperature curve LC300 standard, extended rod and cable probes EN flanged process connections (7ML5670, 7ML5671, 7ML5672 and 7ML5673) Permitted operating pressures P 0 bar (580 psi) 30 bar (35 psi) 20 bar (290 psi) PN 0 1) Atmospheric -1 bar (-1.5 psi) -150 ºC (-238 ºF) -100 ºC (-18 ºF) 10 bar (15 psi) -0 ºF 1 ºF (-0 ºC) (-10 ºC) -50 ºC (-58 ºF) -29 ºC (-20 ºF) 100 ºF (38 ºC) 200 ºF (93 ºC) 0 ºC RT 50 ºC 100 ºC (32 ºF) (122 ºF) (212 ºF) 300 ºF (19 ºC) 150 ºC (302 ºF) 00 ºF (20 ºC) 200 ºC (392 ºF) 500 ºF (260 ºC) 250 ºC (82 ºF) 600 ºF (315 ºC) 300 ºC (572 ºF) 700 ºF (371 ºC) 350 ºC (662 ºF) 00 ºC (752 ºF) PN 16 1) Permitted operating temperature T 1) The curve denotes the minimum allowable flange class for the shaded area below. SITRANS LC300 Process Pressure/Temperature derating curves (7ML5626) /33 Siemens FI 01 June 2015

335 Continuous level measurement - Capacitance transmitters SITRANS LC300 Dimensional drawings Threaded (7ML5670) Threaded (7ML5671) Lid clip Electronics/ enclosure PFA insulated probe Ø19 (0.75) * = 30 (1.18) Inactive tip * Y02 1) Measuring length Cable version, non-insulated Threaded (7ML5672) Lid 20 (0.79) Y01 (insertion length) min. = 300 (1) / max. = (197) Stainless steel stilling well Vent PFA insulated probe Cable version, insulated Threaded (7ML5673) 2) 3) 20 (0.79) Ø19 (0.75) * Y02 1) Measuring length Y01 (insertion length) min. = 300 (1) / max. = (197) Ø35 (1.38) 2 cable entries 1/2" NPT or M20 x (5.91) M20: 135 (5.32) 1/2" NPT: 150 (5.91) Lid without window Thermal isolator 275 (10.83) Note: 1) Rod version Y02: Shield length = 100 (3.9) for threaded including process connection thread length, 100 (3.9) for welded flange 2) For non-conductive applications only. Non-insulated cable can be shortened on site. Weight is included in measuring length. 3) For liquids and solids applications. Insulated cable cannot be shortened. Weight is not included in measuring length. ) For conductive materials, the measuring length includes the exposed PFA insulated cable only. Any fluid contact with the upper rod assembly will result in a short circuit and incorrect readings. Stainless steel cable Ø6 (0.2) Stainless steel weight, actual weight = (1.27 kg [2.80 lb]) Y02 = 105 (.13) 250 (9.8) Measuring length Y01 (insertion length) min. = (0) / max. = (98) PFA insulated cable Ø9 (0.35) Stainless steel weight (electrically isolated but not PFA insulated), actual weight = (2.15 kg [.76 lb]) Y02 = 105 (.13) Measuring length 350 (13.78) See note Y01 (insertion length) min. = (0) / max. = (98) Ø9 (0.35) Ø3,5 (1.36) Mounting eye Ø25 (0.98) Ø12 (0.7) 350 (13.78) 20 (0.79) Ø32 (1.26) Ø3,5 (1.36) SITRANS LC300 - Threaded Process Connections, dimensions in mm (inch) Siemens FI 01 June 2015 /335

336 Continuous level measurement - Capacitance transmitters SITRANS LC300 Welded Flange (7ML5670) Welded Flange (7ML5671) Lid clip Electronics/ enclosure Lid 2 cable entries ½" NPT or M20 x 1.5 M20: 135 (5.32) 1/2" NPT: 150 (5.91) PFA insulated probe Ø19 (0.75) * = 30 (1.18) inactive tip Cable version, non-insulated Welded Flange (7ML5672) Stainless steel cable Ø6 (0.2) Stainless steel weight * 250 (9.8) Y02 1) Measuring length Measuring length Y01 (insertion length) min. = 300 (1) / max. = (197) Y01 (insertion length) min. = (0) / max. = (98) Stainless steel stilling well Vent PFA insulated probe Cable version, insulated Welded Flange (7ML5673) 2) 3) Y02 = 105 (.13) Ø19 (0.75) Ø35 (1.38) PFA insulated cable Ø9 (0.35) Stainless steel weight (electrically isolated but not PFA insulated) Ø32 (1.26) Ø3,5 (1.36) * Y02 1) Measuring length Y02 = 105 (.13) Measuring length 350 (13.78) Y01 (insertion length) min. = 300 (1) / max. = (197) See note 150 (5.91) Y01 (insertion length) min. = (0) / max. = (98) Lid without window Flange Facing (raised face) Flange Class Facing thickness ASME 150/300 2 (0.08) ASME 600/900 7 (0.28) PN16/0 2 (0.08) Notes: 1) Rod version Y02: Shield length = 100 (3.9) for threaded including process connection thread length, 100 (3.9) for welded flange. 2) For non-conductive applications only. Non-insulated cable can be shortened on site. Weight is included in measuring length. 3) For liquids and solids applications. Insulated cable cannot be shortened. Weight is not included in measuring length. ) For conductive materials, the measuring length includes the exposed PFA insulated cable only. Any fluid contact with the upper rod assembly will result in a short circuit and incorrect readings. Ø9 (0.35) Ø3,5 (1.36) Mounting eye Ø25 (0.98) Thermal isolator Ø12 (0.7) 350 (13.78) 20 (0.79) 275 (10.83) SITRANS LC300 - Flanged Process Connections, dimensions in mm (inch) /336 Siemens FI 01 June 2015

337 Continuous level measurement - Capacitance transmitters SITRANS LC300 Schematics With safety barrier white (S) black (O) red (+) Without safety barrier orange (S) black (O) red (+) For factory software update use only Menu / function selector ma (2-wire) current loop measurement signal (not polarity sensitive) Down / - button Up / + button SITRANS LC300 connections Siemens FI 01 June 2015 /337

338 Continuous level measurement - Capacitance transmitters SITRANS LC500 Overview Configuration Installation Build up of material or condensation in active shield area does not affect switch operation. SITRANS LC500 is an inverse frequency shift capacitance level or interface transmitter for extreme and critical process conditions, such as oil and liquified natural gas (LNG) as well as toxic and aggressive chemicals and vapors. Benefits Active-Shield technology so measurement is unaffected by material buildup in active shield section Simple push-button calibration and integrated local display Inverse frequency approach provides high resolution 2-wire loop powered to 20/20 to ma measurement signal Pre-detection alarm and full function diagnostics High temperature and pressure resistant (optional) Full-function diagnostics comply with NAMUR NE 3 Easy calibration locally or via HART (using SIMATIC PDM software) Mounting on non-linear vessels in non-conductive fluids using stilling well. SITRANS LC500 installation, dimensions in mm (inch) Application SITRANS LC500 s advanced electronics provide one-step, push-button calibration and local display for easy on-site installation and setup. The unique mechanical probe design coupled with a high performance transmitter gives superior performance in toxic and aggressive chemicals, acids, caustics, adhesives and in viscous conductive and non-conductive materials. The SMART 2-wire transmitter has HART communications for remote commissioning and inspection. Key Applications: Oil/water or foam/liquid interface measurement in separators or coalescers, cryogenic applications including C0 2 and liquified natural gas (LNG), distillation/ regeneration tanks with high temperatures /338 Siemens FI 01 June 2015

339 Continuous level measurement - Capacitance transmitters SITRANS LC500 Technical specifications Input Measuring range pf Span Min. 3.3 pf Output Solid-state switch Output Galvanically isolated Protection Bipolar Max. switching voltage 30 V (DC) 30 V peak (AC) Max. load current 82 ma Voltage drop < 1 V, typical at 50 ma Time delay (pre or post switching) s Loop current ma/ ma (2-wire current loop) Accuracy (transmitter) Temperature stability 0.15 pf (0 pf) or < 0.25 % (typically < 0.1 %) of actual measured value, whichever is greater over the full temperature range Non-linearity and repeatability < 0.1 % of range and actual measured value respectively Accuracy Deviation < 0.1 % of measured value Rated operating conditions 1) Installation conditions Location Indoor/outdoor Ambient conditions Ambient temperature (transmitter) C ( F) 2) Installation category II Pollution degree Medium conditions Relative dielectric constant ε r Min. 1.5 Process temperature Temperature rating of process seal is pressure dependent. See Pressure/Temperature curves. - Standard (PFA) 3) C ( F) - Cryogenic version C ( F) Contact ceg.smpi@siemens.com for details. Process pressure Pressure rating of process seal is temperature dependent. See Pressure/Temperature curves. Standard (PFA) bar g (2175 psi g) Design Material Wetted parts material - Standard rod 316L stainless steel Probe insulation (rod) PFA Cable 316 stainless steel/ 316 stainless steel PFA Probe diameter Rod version 16 mm (0.63 inch) or 2 mm (0.95 inch) Cable version 9 mm (0.35 inch) with PFA jacket, 6 mm (0.2 inch) without PFA jacket Active shield length Minimum (rod version) Probe length Rod version Cable version 50 mm (1.97 inch), customer selectable (order number Y02) Max. 3.5 m (138 inch) with 16 mm rod, PFA Max. 5.5 m (216 inch) with 2 mm rod, PFA Max. 35 m (1 378 inch) Process connection of probe Threaded mounting NPT [(Taper), ANSI/ASME B1.20.1] R [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] G [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] Flange mounting ASME, EN Enclosure Material Aluminum, epoxy-coated Cable inlet 2 x ½ inch NPT (2 x M20x1.5, IP68 adapter, optional) Degree of protection Type X/NEMAX/IP65, IP68 Power supply V DC User Interface Display Local LCD, digit, each and limited alpha characters Rotary function switch For selecting programmable menu items Push buttons Red +, blue -, used in conjunction with rotary switch for programming Features Measurement current signaling According to NAMUR NE 3, signal ma, fault 3.6 or 21 ma (22 ma) Safety Inputs/outputs fully galvanically isolated Polarity-insensitive current loop Fully potted Integrated safety barrier Diagnostics with fault alarm when: Primary variable (PV) out of limits, system failure in measurement circuit, deviation between A/D and D/A converter, check sum, watch dog and self-checking facility Function rotary switch Positions , A... F SMART communication Conforming to HART Communication Foundation (HCF) Certificates and approvals General Purpose CE, CSA, FM, RCM Non-incendive/Non-sparking CSA/FM Class 1, Div. 2, Groups A, B, C, D T ATEX II 3G 2D EEx na [ib] IIC T6... T T100 C Dust Ignition Proof (Intrinsically Safe Probe Circuit) Explosion Proof (Intrinsically Safe Probe Circuit) Marine CSA/FM Class II and III, Div. 1, Groups E, F, G ATEX II 1/2 GD EEx d [ia] T6 to T1 T100 C FM Class 1, Div. 1, Groups A, B, C, D T ATEX II 1/2 GD EEx d [ia] IIC T6 to T1 Lloyds Register of Shipping, Categories ENV1, ENV2, ENV3 and ENV5, Bureau Veritas 1) When operation is in areas classified as hazardous, observe restrictions according to relevant certificate. See also Pressure/Temperature curves on page /38. 2) Thermal isolator is used if process connection temperature exceeds 85 C (185 F). 3) Not recommended for steam environments Siemens FI 01 June 2015 /339

340 Continuous level measurement - Capacitance transmitters SITRANS LC500 SITRANS LC500 probe version Standard Extended Cable version with Rod Sensor Process connection types Threaded or welded flange Single piece flanged Threaded or welded flange Threaded Available as standard Available as standard Flange Available as standard Available as standard Available as standard Process connection materials Stainless steel 316L Available as standard Available as standard Available as standard Probe insulation PFA Available as standard Available as standard Available as standard Length and Process parameters 1) Rod length for PFA 16 mm version Rod length for PFA 2 mm version Cable length Min. 200 mm (7.87 inch) Max mm ( inch) Min. 200 mm (7.87 inch) Max mm (216.5 inch) Min mm (39.37 inch) Max mm ( inch) Min. 200 mm (7.87 inch) Max mm ( inch) Min. 200 mm (7.87 inch) Max mm (216.5 inch) Min mm (39.37 inch) Max mm ( inch) Min. 200 mm (7.87 inch) Max mm ( inch) Min. 200 mm (7.87 inch) Max mm (216.5 inch) Min mm ( inch) 2) Max mm ( inch) 2) Maximum process pressure See Pressure/Temperature curves for specific probe type 5 bar g (73 psi g) Maximum process temperature 100 C (212 F) 1) See Pressure/Temperature curves for specific probe type 2) Refers to total insertion length. See dimension drawing on page /356 for further explanation - Not available as standard /30 Siemens FI 01 June 2015

341 Continuous level measurement - Capacitance transmitters SITRANS LC500 SITRANS LC500, Threaded or Welded Flange 7ML5513- with Cable Sensor Inverse frequency shift capacitance level and interface transmitter for extreme and critical process conditions, such as oil and liquid gas, toxic and aggressive chemicals and vapours. Click on the for the online configuration in the PIA Life Cycle Portal. Version 1) Cable, 9 mm (0.35 inch) diameter, 316 stainless steel with PFA insulation, weighted Add Order code Y01 and plain text: "Insertion length... mm" mm ( inch) 0 E mm ( inch) 1 E mm ( inch) 2 E mm ( inch) 3 E mm ( inch) E Longer lengths possible to a max. of mm (11.83 ft). Contact ceg.smpi@siemens.com for details. Cable, 6 mm (0.2 inch) diameter, 316L stainless steel, non-insulated, weighted (non-conductive media only) Add Order code Y01 and plain text: "Insertion length... mm" mm ( inch) 2) 0 F mm ( inch) 2)3) 1 F mm ( inch) 2)3) 2 F mm ( inch) 2)3) 3 F mm ( inch) 2)3) F Cable lengths up to mm (98.25 inch) are possible for non-conductive media. Cable lengths up to mm ( inch) are possible for conductive media. Contact ceg.smpi@siemens.com for details. Process connection (316L stainless steel) Threaded connection 1½" NPT [(Taper), ANSI/ASME B1.20.1] C 0 R 1½" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] F 0 1¼" NPT [(Taper), ANSI/ASME B1.20.1] K 0 G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), L 0 JIS B 0202] Welded flange, raised face 1½", ASME, 150 Ib B 1 1½", ASME, 300 Ib B 2 1½", ASME, 600 Ib B 3 2", ASME, 150 Ib C 1 2", ASME, 300 Ib C 2 2", ASME, 600 Ib C 3 3", ASME, 150 Ib 3) D 1 3", ASME, 300 Ib 3) D 2 3", ASME, 600 Ib 3) D 3 ", ASME, 150 Ib 3) E 1 ", ASME, 300 Ib 3) E 2 ", ASME, 600 Ib 3) E 3 6", ASME, 150 Ib 3) F 1 6", ASME, 300 Ib 3) F 2 6", ASME, 600 Ib 3) F 3 Welded flange, Type A flat faced DN 0, PN 16 K DN 0, PN 0 K 5 DN 50, PN 16 L DN 50, PN 0 L 5 DN 80, PN 16 M DN 80, PN 0 3) M 5 DN 100, PN 16 3) N DN 100, PN 0 3) N 5 DN 125, PN 16 3) P DN 125, PN 0 3) P 5 (Note: Flange bolting patterns and facings dimensionally correspond to the applicable ASME B16.5, or EN standard.) SITRANS LC500, Threaded or Welded Flange 7ML5513- with Cable Sensor Inverse frequency shift capacitance level and interface transmitter for extreme and critical process conditions, such as oil and liquid gas, toxic and aggressive chemicals and vapours. Approvals General Purpose: CE, CSA, FM, RCM 1 CSA / FM Class I, Div. 2, Groups A, B, C, D 2 CSA / FM Class II, III, Div. 1, Groups E, F, G T ATEX II 3G 2D EEx na [ib] IIC T6... T T 100 C ATEX II 1/2 GD EEx d [ia] IIC T6... T1 T 100 C FM Class I, Div.1, Groups A, B, C, D, T 6 Enclosure/Cable inlet Aluminum epoxy coated 2 x ½" NPT, IP x M20x1.5 (IP68, adapter) 2 Options No additional options A With mounting eye ) B Thermal isolator Without thermal isolator A Isolator, only for use when temperature range is B outside of C ( F), explosion proof approval C ( F) Electronic output 2-wire loop current ma 1 (transmitter MSP _3300 pf) 1) A minimum span of 3 pf must be maintained 2) Available with non-conductive media only 3) Custom shipping methods required. Contact factory for more details. ) Available in PFA insulated version only Order code Further designs Please add "-Z" to and specify Order code(s). Insertion length, specify in plain text: Y01:... mm Y01 Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Y15 Measuring-point number/identification (max. 27 characters) specify in plain text Manufacturer's test certificate: M to DIN 55350, C11 Part 18 and to ISO 9000 Inspection Certificate Type 3.1 per EN 1020 C12 Operating Instructions See page /37 Accessories See page /37 Siemens FI 01 June 2015 /31

342 Continuous level measurement - Capacitance transmitters SITRANS LC500 SITRANS LC500, Threaded or Welded Flange, 7ML5515- with Rod Sensor Inverse frequency shift capacitance level and interface transmitter for extreme and critical process conditions, such as oil and liquid gas, toxic and aggressive chemicals and vapours. Click on the for the online configuration in the PIA Life Cycle Portal. Version Rod, 16 mm (0.63 inch), PFA insulated Add Order code Y01 and Y02 and plain text: "Insertion length... mm and active shield length... mm" mm ( inch) 1) 0 A mm ( inch) 1 A mm ( inch) 2) 2 A mm ( inch) 2) 3 A Rod, 16 mm (0.63 inch), PFA insulated with 35 mm (1.38 inch) stilling well in 316L stainless steel Add Order code Y01 and Y02 and plain text: "Insertion length... mm and active shield length... mm" mm ( inch) 1)3) 0 B mm ( inch) 3) 1 B mm ( inch) 2)3) 2 B mm ( inch) 2)3) 3 B Rod, 2 mm (0.9 inch), PFA insulated Add Order code Y01 and Y02 and plain text: "Insertion length... mm and active shield length... mm" mm ( inch) ) 0 C mm ( inch) ) 1 C mm ( inch) 2)) 2 C mm ( inch) 2)) 3 C mm ( inch) 2)) C mm ( inch) 2)) 5 C Rod, 2 mm (0.9 inch), PFA insulated with 8 mm (1.89 inch) stilling well in 316L stainless steel Add Order code Y01 and Y02 and plain text: "Insertion length... mm and active shield length... mm" mm ( inch) 5) 0 D mm ( inch) 5) 1 D mm ( inch) 2)5) 2 D mm ( inch) 2)5) 3 D mm ( inch) 2)5) D mm ( inch) 2)5) 5 D Process connection (316L stainless steel) Threaded connection ¾" NPT [(Taper), ANSI/ASME B1.20.1] A 0 1" NPT [(Taper), ANSI/ASME B1.20.1] B 0 1½" NPT [(Taper), ANSI/ASME B1.20.1] C 0 2" NPT [(Taper), ANSI/ASME B1.20.1] D 0 R ¾" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] E 0 R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] F 0 R 1½" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] J 0 R 2" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] K 0 1¼" NPT [(Taper), ANSI/ASME B1.20.1] N 0 G ¾" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] P 0 G 1" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] R 0 G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), S 0 JIS B 0202] G 2" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] T 0 SITRANS LC500, Threaded or Welded Flange, 7ML5515- with Rod Sensor Inverse frequency shift capacitance level and interface transmitter for extreme and critical process conditions, such as oil and liquid gas, toxic and aggressive chemicals and vapours. Welded flange, raised face 1½", ASME, 150 Ib B 1 1½", ASME, 300 Ib B 2 1½", ASME, 600 Ib B 3 2", ASME, 150 Ib C 1 2", ASME, 300 Ib C 2 2", ASME, 600 Ib C 3 3", ASME, 150 Ib 2) D 1 3", ASME, 300 Ib 2) D 2 3", ASME, 600 Ib 2) D 3 ", ASME, 150 Ib 2) E 1 ", ASME, 300 Ib 2) E 2 ", ASME, 600 Ib 2) E 3 6", ASME, 150 Ib 2) F 1 6", ASME, 300 Ib 2) F 2 6", ASME, 600 Ib 2) F 3 Welded flange, Type A flat faced DN 0, PN 16 K DN 0, PN 0 K 5 DN 50, PN 16 L DN 50, PN 0 L 5 DN 80, PN 16 M DN 80, PN 0 2) M 5 DN 100, PN 16 2) N DN 100, PN 0 2) N 5 DN 125, PN 16 2) P DN 125, PN 0 2) P 5 (Note: Flange bolting patterns and facings dimensionally correspond to the applicable ASME B16.5, or EN standard.) Approvals General Purpose: CE, CSA, FM, RCM 1 CSA / FM Class I, Div. 2, Groups A, B, C, D 2 CSA / FM Class II, III, Div. 1, Groups E, F, G T ATEX II 3G 2D EEx na [ib] IIC T6... T T 100 C ATEX II 1/2 GD EEx d [ia] IIC T6... T1 T 100 C FM Class I, Div.1, Groups A, B, C, D, T 6 Enclosure/Cable inlet Aluminum epoxy coated 2 x ½" NPT, IP x M20 x1.5 (IP68, adapter) 2 Options No additional options A Thermal isolator/remote version Without thermal isolator or remote electronics A Thermal isolator, only for use when temperature B range is outside of C ( F), explosion proof approval C ( F) Remote electronics with mounting bracket and cable 6) Length: 2 m (79 inch) C Length: 3 m (118 inch) D Length: m (158 inch) E Length: 5 m (197 inch) F Electronic output 2-wire loop current ma 1 (transmitter MSP _3300 pf) 1) A minimum span of 3 pf must be maintained 2) Custom shipping methods required. Contact factory for more details. 3) Available with process connection 1½" or larger ) Available with process connection 1" or larger 5) Available with process connection 2 " or larger 6) Available with approval option 1 only /32 Siemens FI 01 June 2015

343 Continuous level measurement - Capacitance transmitters SITRANS LC500 Further designs Please add "-Z" to and specify Order code(s). Insertion length, specify in plain text: Y01:... mm Active shield length, specify in plain text [min. length is 50 mm (2 inch)]: Y02:... mm Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Measuring-point number/identification (max. 27 characters) specify in plain text Manufacturer's test certificate: M to DIN 55350, Part 18 and to ISO 9000 Inspection Certificate Type 3.1 per EN 1020 Manufacturing Test Report (Electrode Test) Order code Y01 Y02 Y15 C11 C12 C18 Operating Instructions See page /37 Accessories See page /37 Siemens FI 01 June 2015 /33

344 Continuous level measurement - Capacitance transmitters SITRANS LC500 SITRANS LC500, Single Piece Flanged with 7ML5517- Rod Sensor Inverse frequency shift capacitance level and interface transmitter for extreme and critical process conditions, such as oil and liquid gas, toxic and aggressive chemicals and vapours. Click on the for the online configuration in the PIA Life Cycle Portal. Version Rod, 16 mm (0.63 inch), PFA insulated Add Order code Y01 and Y02 and plain text: "Insertion length... mm and active shield length... mm" mm ( inch) 1) 0 A mm ( inch) 1 A mm ( inch) 2) 2 A mm ( inch) 2) 3 A Rod, 16 mm (0.63 inch), PFA insulated with 35 mm (1.3 inch) stilling well in 316L stainless steel Add Order code Y01 and Y02 and plain text: "Insertion length... mm and active shield length... mm" mm ( inch) 0 B mm ( inch) 1 B mm ( inch) 2) 2 B mm ( inch) 2) 3 B Rod, 2 mm (0.9 inch), PFA insulated Add Order code Y01 and Y02 and plain text: "Insertion length... mm and active shield length... mm" mm ( inch) 0 C mm ( inch) 1 C mm ( inch) 2) 2 C mm ( inch) 2) 3 C mm ( inch) 2) C mm ( inch) 2) 5 C Rod, 2 mm (0.9 inch), PFA insulated with 8 mm (1.89 inch) stilling well in 316L stainless steel Add Order code Y01 and Y02 and plain text: "Insertion length... mm and active shield length... mm" mm ( inch) 0 D mm ( inch) 2)3) 1 D mm ( inch) 2)3) 2 D mm ( inch) 2)3) 3 D mm ( inch) 2)3) D mm ( inch) 2)3) 5 D Process connection (316L stainless steel) Single piece flange, raised face 1½", ASME, 150 Ib B 1 1½", ASME, 300 Ib B 2 1½", ASME, 600 Ib B 3 2", ASME, 150 Ib C 1 2", ASME, 300 Ib C 2 2", ASME, 600 Ib C 3 3", ASME, 150 Ib 2) D 1 3", ASME, 300 Ib 2) D 2 3", ASME, 600 Ib 2) D 3 ", ASME, 150 Ib 2) E 1 ", ASME, 300 Ib 2) E 2 ", ASME, 600 Ib 2) E 3 6", ASME, 150 Ib 2) F 1 6", ASME, 300 Ib 2) F 2 6", ASME, 600 Ib 2) F 3 SITRANS LC500, Single Piece Flanged with Rod Sensor Inverse frequency shift capacitance level and 7ML interface transmitter for extreme and critical process conditions, such as oil and liquid gas, toxic and aggressive chemicals and vapours. Single piece flange, Type B1 raised face DN 0, PN 16 K DN 0, PN 0 K 5 DN 50, PN 16 L DN 50, PN 0 L 5 DN 80, PN 16 M DN 80, PN 0 2) M 5 DN 100, PN 16 2) N DN 100, PN 0 2) N 5 DN 125, PN 16 2) P DN 125, PN 0 2) P 5 Single piece flange with PTFE flange facing (applicable with versions 0A... 3A and 0C... 5C) ) 1½" ASME, 150 Ib B 1½", ASME, 300 Ib B 5 1½", ASME, 600 Ib B 6 2", ASME, 150 Ib C 2", ASME, 300 Ib C 5 2", ASME, 600 Ib C 6 3", ASME, 150 Ib 2) D 3", ASME, 300 Ib 2) D 5 3", ASME, 600 Ib 2) D 6 ", ASME, 150 Ib 2) E ", ASME, 300 Ib 2) E 5 ", ASME, 600 Ib 2) E 6 6", ASME, 150 Ib 2) F 6", ASME, 300 Ib 2) F 5 6", ASME, 600 Ib 2) F 6 Single piece flange with PTFE flange facing (applicable with versions 0A... 3A, 0C... 5C) ) DN 0, PN 16 K 6 DN 0, PN 0 K 7 DN 50, PN 16 L 6 DN 50, PN 0 L 7 DN 80, PN 16 M 6 DN 80, PN 0 2) M 7 DN 100, PN 16 2) N 6 DN 100, PN 0 2) N 7 DN 125, PN 16 2) P 6 DN 125, PN 0 2) P 7 (Note: Flange bolting patterns and facings dimensionally correspond to the applicable ASME B16.5, or EN standard.) /3 Siemens FI 01 June 2015

345 Continuous level measurement - Capacitance transmitters SITRANS LC500 SITRANS LC500, Single Piece Flanged with 7ML5517- Rod Sensor Inverse frequency shift capacitance level and interface transmitter for extreme and critical process conditions, such as oil and liquid gas, toxic and aggressive chemicals and vapours. Approvals General Purpose: CE, CSA, FM, RCM 1 CSA / FM Class I, Div. 2, Groups A, B, C, D 2 CSA / FM Class II, III, Div. 1, Groups E, F, G T ATEX II 3G 2D EEx na [ib] IIC T6... T T 100 C ATEX II 1/2 GD EEx d [ia] IIC T6... T1 T 100 C FM Class I, Div.1, Groups A, B, C, D, T 6 Enclosure/Cable inlet Aluminum epoxy coated 2 x ½" NPT, IP x M20 x1.5 (IP68, adapter) 2 Options None A Thermal isolator/remote version Without thermal isolator A Isolator, only for use when temperature range is B outside of C ( F), explosion proof approval C ( F) Remote electronics with mounting bracket and cable 5) Length: 2 m (79 inch) C Length: 3 m (118 inch) D Length: m (158 inch) E Length: 5 m (197 inch) F Electronic output 2-wire loop current ma 1 (transmitter MSP _3300 pf) 1) A minimum span of 3 pf must be maintained 2) Custom shipping methods required. Contact factory for more details. 3) Available with process connection 2" or larger, and only available with process connection options C1... F3, L... P5 ) Not available with versions 0E and 0F 5) Available with approval option 1 only Order code Further designs Please add "-Z" to and specify Order code(s). Insertion length, specify in plain text: Y01:... mm Y01 Active shield length, specify in plain text Y02 [min. length is 50 mm (2 inch)]: Y02:... mm Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Y15 Measuring-point number/identification (max. 27 characters) specify in plain text Manufacturer's test certificate: M to DIN 55350, C11 Part 18 and to ISO 9000 Inspection Certificate Type 3.1 per EN 1020 C12 Manufacturing Test Report (Electrode Test) C18 Operating Instructions See page /37 Accessories See page /37 Siemens FI 01 June 2015 /35

346 Continuous level measurement - Capacitance transmitters SITRANS LC500 SITRANS LC500, Extended Cable version with 7ML5523- Rod Sensor, threaded connection or welded flange 1) Inverse frequency shift capacitance level and interface transmitter for short range continuous measurement in large storage vessels. Click on the for the online configuration in the PIA Life Cycle Portal. Version 2) Rod, 16 mm (0.63 inch), PFA insulated and 316L stainless steel flexible extension tube Total insertion length: Add Order code Y01 and plain text: "Total insertion length... mm and Y02 and plain text: Active shield length... mm" 3)) mm ( inch) 1) 0 A mm ( inch) 1) 1 A mm ( inch) 1) 2 A mm ( inch) 1) 3 A mm ( inch) 1) A mm ( inch) 1) 5 A Rod, 2 mm (0.9 inch), PFA insulated and 316L stainless steel flexible extension tube Total insertion length: Add Order code Y01 and plain text: "Total insertion length... mm and Y02 and plain text: Active shield length... mm" 3)) mm ( inch) 1) 0 B mm ( inch) 1) 1 B mm ( inch) 1) 2 B mm ( inch) 1) 3 B mm ( inch) 1) B mm ( inch) 1) 5 B Process connection (316L stainless steel) Threaded connection 2" NPT [(Taper), ANSI/ASME B1.20.1] A 0 R 2" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] B 0 G 2" [(BSPP), EN ISO 228-1/PF (JIS-P) JIS B 0202] D 0 Welded flange, raised face 2", ASME, 150 Ib C 1 2", ASME, 300 Ib C 2 3", ASME, 150 Ib 1) D 1 3", ASME, 300 Ib 1) D 2 ", ASME, 150 Ib 1) E 1 ", ASME, 300 Ib 1) E 2 6", ASME, 150 Ib 1) F 1 6", ASME, 300 Ib 1) F 2 Welded flange, Type A flat faced DN 50, PN 16 L DN 50, PN 0 L 5 DN 80, PN 16 M DN 80, PN 0 1) M 5 DN 100, PN 16 1) N DN 100, PN 0 1) N 5 DN 125, PN 16 1) P DN 125, PN 0 1) P 5 (Note: Flange bolting patterns and facings dimensionally correspond to the applicable ASME B16.5, or EN standard.) Approvals General Purpose: CE, CSA, FM, RCM 1 CSA / FM Class I, Div. 2, Groups A, B, C, D 2 CSA / FM Class II, III, Div. 1, Groups E, F, G T ATEX II 3G 2D EEx na [ib] IIC T6... T T 100 C ATEX II 1/2 GD EEx d [ia] IIC T6... T1 T 100 C FM Class I, Div. 1, Groups A, B, C, D T 6 SITRANS LC500, Extended Cable version with 7ML5523- Rod Sensor, threaded connection or welded flange 1) Inverse frequency shift capacitance level and interface transmitter for short range continuous measurement in large storage vessels. Enclosure/Cable inlet Aluminum epoxy coated 2 x ½" NPT, IP x M20x1.5 (IP68, adapter) 2 Options No additional options A With mounting eye B Thermal isolator Without thermal isolator Isolator, only for use when temperature range is outside of C ( F), explosion proof approval C ( F) Electronic output 2-wire loop current ma (transmitter MSP _3300 pf) 1) Custom shipping methods required. Contact factory for more details. 2) A minimum span of 3 pf must be maintained. 3) See dimension drawings on page /356 for further explanation of Y01. ) Inactive length is equal to the flexible extension plus transition. See dimension drawings on page /356 for further explanation of Y02. A B 1 /36 Siemens FI 01 June 2015

347 Continuous level measurement - Capacitance transmitters SITRANS LC500 Order code Further designs Accessories Please add "-Z" to and specify Order code(s). Insertion length, specify in plain text: Y01: to mm (Includes measuring range plus cable extension) - see dimensional information on page /356 Active shield/cable extension length, specify in plain text [min. length is 50 mm (2 inch)]: Y02: to mm (see dimensional information on page /356) Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Measuring-point number/identification (max. 27 characters) specify in plain text Manufacturer's test certificate M to DIN 55350, Part 18 and to ISO 9000 Y01 Y02 Y15 C11 General Purpose 1/2" NPT General Purpose Cable Entry IP68/IP69K NEMA6, C ( F), cable size mm ( inch) M20x1.5 General Purpose Cable Entry IP68/IP69K NEMA6, C ( F), cable size mm ( inch) Hazardous Locations 1/2" NPT EMC rated Cable Gland: Dust Ignition Proof, Flameproof Exd, and Increased Safety ATEX II 2 GD ExtD A21 (Zone 1, Zone 2, Zone 21, Zone 22, and in Gas Groups IIA,IIB and IIC) C IP66, IP67, IP68, NEMAX, cable sizes mm ( inch) 7ML1830-1JA 7ML1830-1JC 7ML1830-1JB Inspection Certificate Type 3.1 per EN 1020 Operating Instructions English French Spanish German Note: The Operating Instructions should be ordered as a separate line item on the order. This device is shipped with the Siemens Milltronics manual DVD containing the ATEX Quick Start and Operating Instructions library. C12 7ML1998-5GE0 7ML1998-5GE12 7ML1998-5GE21 7ML1998-5GE33 M20 EMC rated Cable Gland: Dust Ignition Proof, Flameproof Exd, and Increased Safety ATEX II 2 GD ExtD A21 (Zone 1, Zone 2, Zone 21, Zone 22 and in Gas Groups IIA,IIB and IIC) C IP66, IP67, IP68, NEMAX, cable sizes mm ( inch) Transmitter, MSP , 330 PF 1) Transmitter, MSP , PF 1) Transmitter, MSP , PF (used with conductive fluids and probe lengths > mm) 1) SITRANS RD100, loop powered display - see Chapter 7 SITRANS RD200, universal input display with Modbus conversion - see Chapter 7 7ML1830-1JD 7ML1830-1JP 7ML1830-1JQ 7ML1830-1JR 7ML ML SITRANS RD300, dual line display with totalizer and linearization curve and Modbus conversion - see Chapter 7 7ML SITRANS RD500 web, universal remote monitoring solution for instrumentation - see Chapter 7 7ML For applicable back up point level switch - see point level measurement section 1) Transmitters not suitable for Intrinsically Safe application (ATEX II 1G EEx ia IIC T or CSA/FM Class 1 Div. 1 Groups A, B, C and D Please contact ceg.smpi@siemens.com for special requests. Siemens FI 01 June 2015 /37

348 Continuous level measurement - Capacitance transmitters SITRANS LC500 Characteristic curves Pressure/temperature curve LC500 cable probes threaded process connections (7ML5513) Permitted operating pressures P 30 bar (35 psi) 20 bar (290 psi) Atmospheric -1 bar (-1.5 psi) -150 ºC (-238 ºF) -100 ºC (-18 ºF) 10 bar (15 psi) -0 ºF 1 ºF (-0 ºC) (-10 ºC) -50 ºC (-58 ºF) 100 ºF (38 ºC) 200 ºF (93 ºC) 0 ºC RT 50 ºC 100 ºC (32 ºF) (122 ºF) (212 ºF) 300 ºF (19 ºC) 150 ºC (302 ºF) 00 ºF (20 ºC) 200 ºC (392 ºF) 500 ºF (260 ºC) 250 ºC (82 ºF) -29 ºC (-20 ºF) Permitted operating temperature T Example: permitted operating pressure = 10 bar (15 psi) at 75 C SITRANS LC500 Process Pressure/Temperature derating curves (7ML5513) /38 Siemens FI 01 June 2015

349 Continuous level measurement - Capacitance transmitters SITRANS LC500 Pressure/temperature curve LC500 PFA rod probes Threaded process connections (7ML5515) Permitted operating pressures P 150 bar (2.175 psi) 10 bar (2.030 psi) 130 bar (1.885 psi) 120 bar (1.70 psi) 110 bar (1.595 psi) 100 bar (1.50 psi) 90 bar (1.305 psi) 80 bar (1.160 psi) 70 bar (1.015 psi) 60 bar (870 psi) 50 bar (725 psi) 0 bar (580 psi) 30 bar (35 psi) 20 bar (290 psi) Atmospheric -1 bar (-1.5 psi) -150 ºC (-238 ºF) -100 ºC (-18 ºF) 10 bar (15 psi) -0 ºF 1 ºF (-0 ºC) (-10 ºC) -50 ºC (-58 ºF) -29 ºC (-20 ºF) 100 ºF (38 ºC) 200 ºF (93 ºC) 0 ºC RT 50 ºC 100 ºC (32 ºF) (122 ºF) (212 ºF) 300 ºF (19 ºC) 150 ºC (302 ºF) 00 ºF (20 ºC) 200 ºC (392 ºF) 500 ºF (260 ºC) 250 ºC (82 ºF) Permitted operating temperature T SITRANS LC500 Process Pressure/Temperature derating curves (7ML5515) Siemens FI 01 June 2015 /39

350 Continuous level measurement - Capacitance transmitters SITRANS LC500 Pressure/temperature curve LC500 cable probes ASME flanged process connections (7ML5513) Permitted operating pressures P 20 bar (290 psi) Atmospheric -1 bar (-1.5 psi) -150 ºC (-238 ºF) -100 ºC (-18 ºF) 10 bar (15 psi) -0 ºF 1 ºF (-0 ºC) (-10 ºC) -50 ºC (-58 ºF) -29 ºC (-20 ºF) 100 ºF (38 ºC) 200 ºF (93 ºC) 0 ºC RT 50 ºC 100 ºC (32 ºF) (122 ºF) (212 ºF) 300 ºF (19 ºC) 150 ºC (302 ºF) 00 ºF (20 ºC) 200 ºC (392 ºF) 500 ºF (260 ºC) 250 ºC (82 ºF) 600 ºF (315 ºC) 300 ºC (572 ºF) ASME 150 lb 1) 700 ºF (371 ºC) 350 ºC (662 ºF) 00 ºC (752 ºF) Permitted operating temperature T 1) The curve denotes the minimum allowable flange class for the shaded area below. SITRANS LC500 Process Pressure/Temperature derating curves (7ML5513) /350 Siemens FI 01 June 2015

351 Continuous level measurement - Capacitance transmitters SITRANS LC500 Pressure/temperature curve LC500 PFA rod probes ASME flanged process connections (7ML5515 and 7ML5517) Permitted operating pressures P 150 bar (2.175 psi) 10 bar (2.030 psi) 130 bar (1.885 psi) 120 bar (1.70 psi) 110 bar (1.595 psi) 100 bar (1.50 psi) 90 bar (1.305 psi) 80 bar (1.160 psi) 70 bar (1.015 psi) 60 bar (870 psi) 50 bar (725 psi) ASME 600 lb 1) 0 bar (580 psi) 30 bar (35 psi) ASME 300 lb 1) 20 bar (290 psi) Atmospheric -1 bar (-1.5 psi) -150 ºC (-238 ºF) -100 ºC (-18 ºF) 10 bar (15 psi) -0 ºF 1 ºF (-0 ºC) (-10 ºC) -50 ºC (-58 ºF) -29 ºC (-20 ºF) 100 ºF (38 ºC) 200 ºF (93 ºC) 0 ºC RT 50 ºC 100 ºC (32 ºF) (122 ºF) (212 ºF) 300 ºF (19 ºC) 150 ºC (302 ºF) 00 ºF (20 ºC) 200 ºC (392 ºF) 500 ºF (260 ºC) 250 ºC (82 ºF) 600 ºF (315 ºC) 300 ºC (572 ºF) 700 ºF (371 ºC) 350 ºC (662 ºF) ASME 150 lb 1) 00 ºC (752 ºF) Permitted operating temperature T 1) The curve denotes the minimum allowable flange class for the shaded area below. SITRANS LC500 Process Pressure/Temperature derating curves (7ML5515 and 7ML5517) Siemens FI 01 June 2015 /351

352 Continuous level measurement - Capacitance transmitters SITRANS LC500 Pressure/temperature curve LC500 cable probes EN flanged process connections (7ML5513) Permitted operating pressures P 20 bar (290 psi) Atmospheric -1 bar (-1.5 psi) -150 ºC (-238 ºF) -100 ºC (-18 ºF) 10 bar (15 psi) -0 ºF 1 ºF (-0 ºC) (-10 ºC) -50 ºC (-58 ºF) -29 ºC (-20 ºF) 100 ºF (38 ºC) 200 ºF (93 ºC) 0 ºC RT 50 ºC 100 ºC (32 ºF) (122 ºF) (212 ºF) 300 ºF (19 ºC) 150 ºC (302 ºF) 00 ºF (20 ºC) 200 ºC (392 ºF) 500 ºF (260 ºC) 250 ºC (82 ºF) 600 ºF (315 ºC) 300 ºC (572 ºF) 700 ºF (371 ºC) 350 ºC (662 ºF) PN 16 1) 00 ºC (752 ºF) Permitted operating temperature T 1) The curve denotes the minimum allowable flange class for the shaded area below. SITRANS LC500 Process Pressure/Temperature derating curves (7ML5513) /352 Siemens FI 01 June 2015

353 Continuous level measurement - Capacitance transmitters SITRANS LC500 Pressure/temperature curve LC500 PFA rod probes EN flanged process connections (7ML5515 and 7ML5517) Permitted operating pressures P 150 bar (2.175 psi) 10 bar (2.030 psi) 130 bar (1.885 psi) 120 bar (1.70 psi) 110 bar (1.595 psi) 100 bar (1.50 psi) 90 bar (1.305 psi) 80 bar (1.160 psi) 70 bar (1.015 psi) 60 bar (870 psi) 50 bar (725 psi) 0 bar (580 psi) 30 bar (35 psi) 20 bar (290 psi) PN 0 1) Atmospheric -1 bar (-1.5 psi) -150 ºC (-238 ºF) -100 ºC (-18 ºF) 10 bar (15 psi) -0 ºF 1 ºF (-0 ºC) (-10 ºC) -50 ºC (-58 ºF) -29 ºC (-20 ºF) 100 ºF (38 ºC) 200 ºF (93 ºC) 0 ºC RT 50 ºC 100 ºC (32 ºF) (122 ºF) (212 ºF) 300 ºF (19 ºC) 150 ºC (302 ºF) 00 ºF (20 ºC) 200 ºC (392 ºF) 500 ºF (260 ºC) 250 ºC (82 ºF) 600 ºF (315 ºC) 300 ºC (572 ºF) 700 ºF (371 ºC) 350 ºC (662 ºF) 00 ºC (752 ºF) PN 16 1) Permitted operating temperature T 1) The curve denotes the minimum allowable flange class for the shaded area below. SITRANS LC500 Process Pressure/Temperature derating curves (7ML5515 and 7ML5517) Siemens FI 01 June 2015 /353

354 Continuous level measurement - Capacitance transmitters SITRANS LC500 Pressure/temperature curve LC500 single piece flanged rod probes with PTFE facing EN flanged process connections (7ML5517) Permitted operating pressures P 80 bar (1.160 psi) 70 bar (1.015 psi) 60 bar (870 psi) 50 bar (725 psi) 0 bar (580 psi) 30 bar (35 psi) 20 bar (290 psi) PN 0 1) Atmospheric -1 bar (-1.5 psi) -150 ºC (-238 ºF) -100 ºC (-18 ºF) 10 bar (15 psi) -0 ºF (-0 ºC) -50 ºC (-58 ºF) -29 ºC (-20 ºF) 1 ºF (-10 ºC) 100 ºF (38 ºC) 200 ºF (93 ºC) 0 ºC RT 50 ºC 100 ºC (32 ºF) (122 ºF) (212 ºF) 300 ºF (19 ºC) 150 ºC (302 ºF) 00 ºF (20 ºC) 200 ºC (392 ºF) 500 ºF (260 ºC) 250 ºC (82 ºF) 600 ºF (315 ºC) 300 ºC (572 ºF) 700 ºF (371 ºC) 350 ºC (662 ºF) 00 ºC (752 ºF) PN 16 1) Permitted operating temperature T 1) The curve denotes the minimum allowable flange class for the shaded area below. SITRANS LC500 Process Pressure/Temperature derating curves (7ML5517) /35 Siemens FI 01 June 2015

355 Continuous level measurement - Capacitance transmitters SITRANS LC500 Pressure/temperature curve LC500 single piece flanged rod probes with PTFE facing ASME flanged process connections (7ML5517) Permitted operating pressures P 80 bar (1.160 psi) 70 bar (1.015 psi) 60 bar (870 psi) 50 bar (725 psi) 0 bar (580 psi) ASME 600 lb 1) 30 bar (35 psi) ASME 300 lb 1) 20 bar (290 psi) Atmospheric -1 bar (-1.5 psi) -150 ºC (-238 ºF) -100 ºC (-18 ºF) 10 bar (15 psi) -0 ºF 1 ºF (-0 ºC) (-10 ºC) -50 ºC (-58 ºF) -29 ºC (-20 ºF) 100 ºF (38 ºC) 200 ºF (93 ºC) 0 ºC RT 50 ºC 100 ºC (32 ºF) (122 ºF) (212 ºF) 300 ºF (19 ºC) 150 ºC (302 ºF) 00 ºF (20 ºC) 200 ºC (392 ºF) 500 ºF (260 ºC) 250 ºC (82 ºF) 600 ºF (315 ºC) 300 ºC (572 ºF) ASME 150 lb 1) 700 ºF (371 ºC) 350 ºC (662 ºF) 00 ºC (752 ºF) Permitted operating temperature T 1) The curve denotes the minimum allowable flange class for the shaded area below. SITRANS LC500 Process Pressure/Temperature derating curves (7ML5517) Siemens FI 01 June 2015 /355

356 Continuous level measurement - Capacitance transmitters SITRANS LC500 Dimensional drawings Cable version, non-insulated welded flange (7ML5513) Cable version, insulated welded flange (7ML5513) Transmitter/ electronics 20 (0.79) Option for mounting eye only available for PFA insulated cable Stainless steel cable Ø6 (0.2) Stainless steel weight Measuring length Y01 (insertion length) min. = (39.0) / max. = (1 378) Extended cable version with rod sensor welded flange (7ML5523) Stainless steel flexible tube Ø16 (0.63) 63 (2.8) 92 (3.62) Measuring length 92 (3.62) 250 (9.8) Ø32 (1.26) 20 (0.79) Y02 Inactive length Ø8 (1.88) Y01 (insertion length) min. = (197) / max. = (1 378) 20 (0.79) Mounting eye option PFA insulated probe Mounting eye Ø12 (0.7) Ø9 (0.35) Stainless steel weight Ø25 (0.98) Measuring length Extended cable version with rod sensor welded flange (7ML5523) Stainless steel flexible tube Ø0 (1.57) Ø2 (0.9) Ø35 (1.37) 350 (13.78) 5 (2.12) Measuring length Y02 Inactive length Y01 (insertion length) min. = (39.0) / max. = (1 378) Ø3.5 (1.36) Y01 (insertion length) min. = (197) / max. = (1 378) 15 (0.60) Ø3.5 (1.36) Mounting eye Ø25 (0.98) Note: 1) Applicable for non-conductive media only. Cable can be shortened on site. Weight is included in measuring length. 2) Applicable for both liquids and solids. Cable cannot be shortened. Weight is not part of measuring length. 3) For Y02 lengths greater than (197), cable is inactive and is not actively shielded. ) Minimum length = 200 (7.87), maximum length = (216.5) 5) Insertion length Y01 = Y02 + measuring length + 92 (3.62) 6) Insertion length Y01 = Y02 + measuring length + 15 (0.59) Inactive tip 100 (3.9) Ø9 (0.35) Mounting eye option Ø12 (0.7) 350 (13.78) 20 (0.79) SITRANS LC500 - Cable Versions, dimensions in mm (inch) /356 Siemens FI 01 June 2015

357 Continuous level measurement - Capacitance transmitters SITRANS LC500 Cable version, non-insulated Welded flange (7ML5513) Cable version, insulated Welded flange (7ML5513) 1) 2) Transmitter/ electronics Option for mounting eye only available for PFA insulated cable Ø9 (0.35) Stainless steel cable Ø6 (0.2) Stainless steel weight, actual weight = (1.27 kg [2.80 lb]) 250 (9.8) Measuring length Y01 (insertion length) max. = (1 378) PFA insulated probe Ø9 (0.35) Stainless steel weight, actual weight = (2.15 kg [.75 lb]) Measuring length 350 (13.78) Y01 (insertion length) max. = (1 378) Ø3.5 (1.36) Mounting eye Ø25 (0.98) Ø12 (0.7) 350 (13.78) 20 (0.79) Ø32 (1.26) Ø3.5 (1.36) Extended cable version with rod sensor Welded flange (7ML5523) 3) Extended cable version with rod sensor Welded flange (7ML5523) 3) Stainless steel flexible tube Ø16 (0.63) 63 (2.8) 92 (3.62) ) Measuring length 92 (3.62) Y02 Inactive length Y01 (insertion length) min. = (197) / max. = (1 378) 5) Ø8 (1.88) 20 (0.79) Mounting eye option Mounting eye Ø12 (0.7) Ø25 (0.98) Stainless steel flexible tube Ø0 (1.57) Ø2 (0.9) Ø35 (1.37) 5 (2.12) Y02 Inactive length ) Measuring length Y01 (insertion length) min. = (197) / max. = (1 378) 6) 15 (0.60) Note: 1) Applicable for non-conductive media only. Cable can be shortened on site. Weight is included in measuring length. 2) Applicable for both liquids and solids. Cable cannot be shortened. Weight is not part of measuring length. 3) For Y02 lengths greater than (197), cable is inactive and is not actively shielded. ) Minimum length = 200 (7.87), maximum length = (216.5) 5) Insertion length Y01 = Y02 + measuring length + 92 (3.62) 6) Insertion length Y01 = Y02 + measuring length + 15 (0.59) Inactive tip 100 (3.9) Mounting eye option SITRANS LC500 - Cable Versions, dimensions in mm (inch) Siemens FI 01 June 2015 /357

358 Continuous level measurement - Capacitance transmitters SITRANS LC500 Rod version threaded (7ML5515) Rod version with stilling well threaded (7ML5515) Remote electronics with mounting bracket option threaded (7ML5515) Transmitter/ electronics 205 (8.1) 205 (8.1) 150 (6) PFA insulated probe Ø16 (0.63) or Ø2 (0.9) * = 30 (1.18) inactive tip 20 (0.79) * Measuring length 1) Y02 1) Y01 (insertion length) min. = 200 (7.87) / max. = (138), Ø16 (0.63) min. = 200 (7.87) / max. = (216), Ø2 (0.9) Note: 1) Minimum Y02 (active shield length) = 50 (1.96), minimum measuring length = 200 (7.87) Stainless steel stilling well Vent holes or optional slots PFA insulated probe Ø16 (0.63) or Ø2 (0.9) Ø35 (1.38) or Ø8 (1.89) Y02 1) 1) * Measuring length Y01 (insertion length) min. = 200 (7.87) / max. = (138), Ø16 (0.63) min. = 200 (7.87) / max. = (216), Ø2 (0.9) General purpose approval only. Standard configuration (all versions) With explosion-proof seal option (all versions) Stainless steel flexible tube 270 (10.6) 205 (8.1) M20: 160 (6.3) 1/2" NPT: 230 (9.1) With thermal isolator option (all versions) Thermal isolator 30 (16.9) SITRANS LC500 - Rod Versions, dimensions in mm (inch) /358 Siemens FI 01 June 2015

359 Continuous level measurement - Capacitance transmitters SITRANS LC500 Rod version Welded flange (7ML5515) Single piece flange (7ML5517) Rod version with stilling well Welded flange (7ML5515) Single piece flange (7ML5517) Remote electronics with mounting bracket option Welded flange (7ML5515) Single piece flange (7ML5517) Transmitter/ electronics PFA insulated probe * Measuring length 1) 1) Y02 2) Y01 (insertion length) 205 (8.1) min. = 200 (7.87) / max. = (138), Ø16 (0.63) (Typical) min. = 200 (7.87) / max. = (216), Ø2 (0.9) Stainless steel stilling well Vent holes or optional slots PFA insulated probe Ø16 (0.63) or Ø2 (0.9) Y02 1) 1) * Measuring length Y01 (insertion length) min. = 200 (7.87) / max. = (138), Ø16 (0.63) min. = 200 (7.87) / max. = (216), Ø2 (0.9) 2) Stainless steel flexible tube General purpose approval only. PTFE flange facing option single piece flange only (7ML5517) Raised face flange PTFE flange facing 150 (6) Ø16 (0.63) or Ø2 (0.9) Ø35 (1.38) or Ø8 (1.89) No stilling well or enamel probe available with this option. * = 30 (1.18) inactive tip Standard configuration (all versions) With explosion-proof seal option (all versions) 270 (10.6) 205 (8.1) M20: 160 (6.3) 1/2" NPT: 230 (9.1) With thermal isolator option (all versions) Thermal isolator 30 (16.9) Flange class ASME 150/300 ASME 600/900 PN16/25/0/6 Flange facing (raised face) PTFE facing (additional) Facing thickness 2 (0.08) 7 (0.28) 2 (0.08) 2 (0.08) Notes: 1) Minimum Y02 (active shield length) = 50 (1.96), minimum measuring length = 200 (7.87) 2) Insertion length does not include any raised face/gasket face dimension (see Flange Facing table above). SITRANS LC500 - Rod Versions, dimensions in mm (inch) Siemens FI 01 June 2015 /359

360 Tampering voids warranty Siemens AG 2015 Continuous level measurement - Capacitance transmitters SITRANS LC500 Schematics Ground lug Protective label Instrument system ground Measuring signal (minicoaxial cable) Type: Ser.: Date: Rev.: Solid state switch relay (any polarity) ma current loop connection (any polarity) Ground connection point for instrument system SITRANS LC500 connections /360 Siemens FI 01 June 2015

361 Continuous level measurement - Capacitance transmitters SITRANS LC300 and LC500 Specials Selection and ordering data LC300 and LC500 Specials 1) LC300 and LC500 Specials 1) LC300 Cable Extensions, 316L stainless steel LC300 Mounting Eye Spare mounting eye (LC300 PFA versions only) A5E LC300 Weight Kit, 316L stainless steel Kit, stainless steel cable extension, 1 m, adjustable by customer A5E Kit, stainless steel cable extension, 3 m, adjustable by customer A5E Kit, stainless steel cable extension, 5 m, adjustable by customer Kit, stainless steel cable extension, 10 m, adjustable by customer Kit, stainless steel cable extension, 15 m, adjustable by customer A5E A5E A5E Kit, Spare stainless steel weight. To be used in any cable version of CLS300, or stainless steel cable version of LC300 LC500 Gasket (IP65), Silicone A5E Kit, stainless steel cable extension, 20 m, adjustable by customer A5E LC300 Cable Extensions, 316 stainless steel with PFA coating Spare gasket, LC500 enclosure version, IP65 A5E LC500 Blind Lid Kit, PFA cable extension, 1 m Kit, PFA cable extension, 3 m A5E A5E Spare LC500 aluminum blind lid LC500 Mounting Eye A5E Kit, PFA cable extension, 5 m A5E Kit, PFA cable extension, 10 m A5E Kit, PFA cable extension, 15 m Kit, PFA cable extension, 20 m A5E A5E Spare mounting eye (PFA cable version only) LC500 Mounting Bracket A5E Spare mounting bracket LC500 Sanitary Versions 2) A5E ) Special flange sizes and facings are available. Please contact ceg.smpi@siemens.com for part number and pricing. Submit Application Questionnaire found on page /11. 2) Please contact ceg.smpi@siemens.com for part number and pricing. Submit Application Questionnaire found on page /11. Please contact ceg.smpi@siemens.com for special requests. Siemens FI 01 June 2015 /361

362 Communication SmartLinx module Overview Technical specifications Module type PROFIBUS DP Interface RS 85 (PROFIBUS standard) Transmission rate All valid PROFIBUS DP rates from Kbps Mbps Rack address Connection Slave SmartLinx module compatibility MultiRanger 100/200 HydroRanger 200 Module type DeviceNet Interface DeviceNet physical layer Transmission rate in kbps 125, 250, 500 Rack address Connection Slave (group 2) SmartLinx module compatibility MultiRanger 100/200 HydroRanger 200 SmartLinx modules provide direct digital connection to popular industrial communications buses with true plug-and-play compatibility with products manufactured by Siemens. Benefits Fast, easy installation Direct connection: no additional installation required Scaleable application layer allows for optimized network bandwidth and memory requirements Modules available for PROFIBUS DP, DeviceNet Application Many Siemens products include HART, PROFIBUS PA and Modbus communications. For additional communication modules, SmartLinx cards are the answer. They re fast and easy to install, and can be added at any time. The module simply plugs into the socket on any SmartLinxenabled product. They require no secondary private buses or gateways and no separate wiring. There are no extra boxes to connect to your network so there s a minimum load on engineering and maintenance staff. SmartLinx provides all data from the instrument, including measurement and status, and allows changes to operation parameters to be done over the bus or telemetry link. The user can select which data in the application layer to transfer over the bus. This selection saves bandwidth and memory and optimizes data throughput and speeds up the network, enabling you to connect more instruments to your network. SmartLinx module for MultiRanger 100/200 and HydroRanger 200 PROFIBUS DP module DeviceNet module Operating Instructions PROFIBUS communications module English French German DeviceNet This device is shipped with the Siemens Milltronics manual DVD containing Quick Starts and Operating Instructions. English French Spare SmartLinx software PROFIBUS DP data diskette DeviceNet data diskette 7ML1830-1HR 7ML1830-1HT 7ML1998-1AQ03 7ML1998-1AQ13 7ML1998-1AQ33 7ML1998-1BH02 7ML1998-1BH12 7ML1830-1CL 7ML1830-1CM /362 Siemens FI 01 June 2015

363 Communication Dolphin Plus Software Overview Dolphin Plus is instrument configuration software that allows you to quickly and easily configure, monitor, tune and diagnose several Siemens level devices remotely (see list below). Remote access is available using your desktop PC or connected directly in the field using a laptop. Benefits Real-time monitoring and adjustment of parameters On-screen visualization of process values Saving and visualization of echo profiles for a wide range of Siemens level meters Copying of data for programming several devices Quick setup and commissioning of device Generation of configuration reports within seconds Note: The Dolphin Plus software is only available in English. Application Dolphin Plus is easy to install and use. Just load the software from the CD. In minutes, you re ready to set up or modify complete parameter configurations for one or more devices. Following configuration, you can alter parameters, upload and download parameter sets to and from disk, and use parameter sets saved from other instruments. Reading of echo profiles permits fine tuning without the need for special instruments. Built-in quick start wizards and help functions guide you through the entire process. Compatibility Dolphin Plus is compatible with Microsoft Windows 95/98/NT/Me/2000/XP and works with a wide range of Siemens products, including: SITRANS LU10 SITRANS LU02 SITRANS LU01 Connection to a Siemens instrument may be a direct RS 232 serial connection or via an RS 85 converter or Siemens infrared ComVerter, depending on the instrument being configured. Meets VDE 2187 user interface requirements. (Most other Siemens level devices use Simatic PDM configuration software.) Dolphin Plus 7ML181- Instrument configuration software to quickly and 7 A A 0 7 easily configure, monitor, tune and diagnose most Siemens devices remotely, from your desktop PC or connected directly in the field using a laptop. Dolphin Plus Software includes a software DVD, and a nine pin adapter with a 2.1 m (82.7 inch) cable for connection to a PC serial port. Click on the for the online configuration in the PIA Life Cycle Portal. RS 85 to RS 232 converter No 0 Yes 1 ComVerter No 0 Yes 1 Operating Instructions Connection manual, English: Included on Dolphin Plus DVD and available at Spare parts Converter, RS 85 to RS 232 (D-Sub) Kit containing one 9-pin D-Sub to RJ11 Adapter and one 2.1 meter telephone cable with two male jacks ComVerter, Infrared link 7ML1830-1HA 7ML1830-1MC 7ML1830-1MM Siemens FI 01 June 2015 /363

Level Measurement. 4/2 Overview

Level Measurement. 4/2 Overview Siemens AG 2017 /2 Overview Point level measurement /8 RF Capacitance switches /10 Pointek CLS100 /16 Pointek CLS200 Standard /25 Pointek CLS200 Digital /3 Pointek CLS200 Standard and Digital /2 Pointek

More information

Level Measurement. 4/2 Product overview

Level Measurement. 4/2 Product overview Siemens AG 2018 /2 Product overview Point level measurement /8 RF Capacitance switches /10 Pointek CLS100 /16 Pointek CLS200 Standard /2 Pointek CLS200 Digital /32 Pointek CLS200 Standard and Digital /0

More information

SITRANS L Level instruments

SITRANS L Level instruments SITRANS L Level instruments /2 Point level measurement /6 Capacitance switches /9 Pointek CLS100 /1 Pointek CLS200 /31 Pointek CLS300 /47 Pointek CLS00 /62 Pointek Specials Electro-mechanical switches

More information

Siemens AG Level Measurement

Siemens AG Level Measurement /2 Product overview Point level measurement /7 Capacitance switches /10 - Pointek CLS100 /1 - Pointek CLS200 - Standard /24 - Pointek CLS200 - Digital /33 - Pointek CLS200 - Standard and Digital /41 -

More information

SITRANS L Level instruments

SITRANS L Level instruments SITRANS L /2 Product overview Point Level measurement /6 Capacitance switches /9 Pointek CLS100 /1 Pointek CLS200 /31 Pointek CLS300 /47 Pointek CLS00 /62 Pointek Specials Vibrating switches /64 SITRANS

More information

Level Measurement Continuous level measurement Radar transmitters

Level Measurement Continuous level measurement Radar transmitters Overview Configuration Mounting on a nozzle is a 2-wire 25 GHz pulse radar level transmitter for continuous monitoring of solids and liquids in storage vessels including extreme levels of dust and high

More information

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview Overview Application It provides excellent results on low dielectric media. is available for standard applications and for applications that require explosion proof protection. features robust enclosure,

More information

Level Measurement Continuous level measurement Radar transmitters

Level Measurement Continuous level measurement Radar transmitters Overview Benefits Process Intelligence for advanced signal processing and quick and easy adjustment Self-guided quick start wizard for plug and play startup 2 GHz provides superior reflective properties

More information

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview Overview Application It provides excellent results on low dielectric media. is available for standard applications and for applications that require explosion proof protection. features robust enclosure,

More information

Level Measurement. Continuous level measurement Radar transmitters SITRANS LR460. 4/258 Siemens FI

Level Measurement. Continuous level measurement Radar transmitters SITRANS LR460. 4/258 Siemens FI Overview The is a -wire, 2 GHz FMCW radar level transmitter with extremely high signal-to-noise ratio and advanced signal processing for continuous monitoring of solids up to 100 m (328 ft). It is ideal

More information

Level instruments. Continuous level measurement - Radar transmitters SITRANS LR300. 5/180 Siemens FI Overview

Level instruments. Continuous level measurement - Radar transmitters SITRANS LR300. 5/180 Siemens FI Overview Overview is a 4-wire, 6 GHz pulse radar level transmitter for continuous and process vessels including high temperature and pressure, to a range of 20 m (66 ft). Benefits Auto False-Echo Suppression Infrared

More information

SITRANS LR 300: High Performance Radar for Level Measurement

SITRANS LR 300: High Performance Radar for Level Measurement SITRANS LR 300: High Performance Radar for Level Measurement Reliable Measurement In Extreme Conditions SITRANS LR 300 delivers high performance level measurement at an affordable price for the chemical,

More information

Level Measurement. Continuous level measurement - Capacitance transmitters SITRANS LC300 5/271. Overview. Configuration

Level Measurement. Continuous level measurement - Capacitance transmitters SITRANS LC300 5/271. Overview. Configuration Siemens G 200 Overview onfiguration Installation uild up of material in active shield area does not affect switch operation. Mounting on a bypass is an inverse frequency shift capacitance continuous level

More information

Level Measurement. Continuous level measurement Capacitance transmitters SITRANS LC300. icenta Controls Ltd

Level Measurement. Continuous level measurement Capacitance transmitters SITRANS LC300. icenta Controls Ltd Overview onfiguration Installation uild up of material in active shield area does not affect switch operation. Mounting on a bypass is an inverse frequency shift capacitance continuous level transmitter

More information

SITRANS L Level instruments

SITRANS L Level instruments Overview is a 2-wire, 6 GHz pulse radar level transmitter for continuous and process vessels including high temperature and pressure, to a range of 20 m (66 ft). Benefits Uni-Construction polypropylene

More information

Level Measurement Continuous level measurement - Radar transmitters

Level Measurement Continuous level measurement - Radar transmitters Overview Configuration Installation Min. 300 mm (1 ft) for every 3 m (10 ft) of vessel wall. is a 2-wire, 6 GHz pulse radar level transmitter for continuous monitoring of liquids and slurries in process

More information

Level Measurement Continuous level measurement Radar transmitters SITRANS LR200. Overview. Configuration

Level Measurement Continuous level measurement Radar transmitters SITRANS LR200. Overview. Configuration Overview Configuration Installation Min. 300 mm (1 ft) for every 3 m (10 ft) of vessel wall. is a 2-wire, 6 GHz pulse radar level transmitter for continuous monitoring of liquids and slurries in process

More information

Level Measurement Continuous level measurement - Radar transmitters

Level Measurement Continuous level measurement - Radar transmitters SITRANS LR250 Horn Antenna Overview Configuration Installation SITRANS LR250 is a 2-wire, 25 GHz pulse radar level transmitter for continuous monitoring of liquids and slurries in storage and process vessels

More information

Level Measurement Continuous level measurement - Radar transmitters

Level Measurement Continuous level measurement - Radar transmitters SITRANS LR250 Horn Antenna Overview Configuration Installation SITRANS LR250 is a 2-wire, 25 GHz pulse radar level transmitter for continuous monitoring of liquids and slurries in storage and process vessels

More information

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR200. 5/200 Siemens FI Overview.

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR200. 5/200 Siemens FI Overview. Overview Configuration Installation min. 300 mm (1 ft) for every 3 m (10 ft) of vessel wall. Note: Beam angle is the width of the cone where the energy density is half of the peak energy density. The peak

More information

INDUSTRIAL CONTROL INSTRUMENTS FOR PROCESS AUTOMATION. Configuration. Installation

INDUSTRIAL CONTROL INSTRUMENTS FOR PROCESS AUTOMATION. Configuration. Installation Overview Configuration Installation 19 beam width: 1.5 horn = 19 2 horn = 15 3 horn = 10 4 horn = 8 is a 2-wire, 25 GHz pulse radar level transmitter for continuous monitoring of liquids and slurries in

More information

Level instruments. Continuous level measurement - Radar transmitters SITRANS LR200. 5/200 Siemens FI Configuration.

Level instruments. Continuous level measurement - Radar transmitters SITRANS LR200. 5/200 Siemens FI Configuration. Coni Fl at Overview Configuration Installation min. 300 mm (1 ft) for every 3 m (10 ft) of vessel wall. Note: Beam angle is the width of the cone where the energy density is half of the peak energy density.

More information

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M Overview Mode of operation The flow measuring principle is based on Faraday s law of electromagnetic induction according to which the sensor converts the flow into an electrical voltage proportional to

More information

Continuous level measurement Radar transmitters

Continuous level measurement Radar transmitters Overview Configuration Installation Min. 300 mm (1 ft) for every 3 m (10 ft) of vessel wall. is a 2-wire, 6 GHz pulse radar level transmitter for continuous monitoring of liquids and slurries in storage

More information

Continuous level measurement Radar transmitters

Continuous level measurement Radar transmitters Overview Configuration Installation min. 300 mm (1 ft) for every 3 m (10 ft) of vessel wall. Note: Beam angle is the width of the cone where the energy density is half of the peak energy density. Beam

More information

Intelligence and reliability

Intelligence and reliability Intelligence and reliability Siemens signal processing technology is based on experience gained from over a million level instruments installed in industrial applications around the world: this technology

More information

Flow Measurement SITRANS F M. Flow sensor MAG /49. Overview

Flow Measurement SITRANS F M. Flow sensor MAG /49. Overview Siemens AG 2010 Flow Measurement Overview Mode of operation The flow measuring principle is based on Faraday s law of electromagnetic induction according to which the sensor converts the flow into an electrical

More information

SITRANS F flowmeters SITRANS F M. Flow sensor MAG /48 Siemens FI Overview

SITRANS F flowmeters SITRANS F M. Flow sensor MAG /48 Siemens FI Overview Siemens AG 2009 Overview Integration The complete flowmeter consists of a flow sensor and an associated transmitter MAG 5000, 6000 or 6000 I. The flexible communication concept USM II simplifies integration

More information

Level Measurement With REFLEX RADAR

Level Measurement With REFLEX RADAR Reflex Radar & TDR HYC-RR02 Elect. Iss. 02 Level Measurement With REFLEX RADAR Why Radar Technology for Level Measurement? INSENSITIVE TO CHANGES IN Dielectric Pressure Vacuum Humidity Dust Viscosity Foam

More information

REFLEX RADAR INDICATOR

REFLEX RADAR INDICATOR REFLEX RADAR INDICATOR Why Radar Technology for Level Measurement? INSENSITIVE TO CHANGES IN Dielectric Pressure Vacuum Humidity Dust Viscosity Foam Temperature THE ADVANTAGES ARE Measuring ranges up to

More information

OEM radar transmitter, for aggressive media level measurement

OEM radar transmitter, for aggressive media level measurement OEM radar transmitter, for aggressive media level measurement C ompact for level measurement up to 20 m 4... 20 ma/hart - 2 wires Adjustable with P C ATEX approvals Type 8136 can be combined with... Type

More information

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview Overview Design The complete flowmeter consists of a flow sensor and an associated transmitter from the Transmag 2 for pulsed alternating field. These are available as remote and compact versions ( 911/E

More information

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M Overview Mode of operation The flow measuring principle is based on Faraday s law of electromagnetic induction according to which the sensor converts the flow into an electrical voltage proportional to

More information

Level instruments. Continuous level measurement - Radar transmitters SITRANS LR250. 5/210 Siemens FI Overview.

Level instruments. Continuous level measurement - Radar transmitters SITRANS LR250. 5/210 Siemens FI Overview. Level instruments Siemens AG 2009 Overview Configuration Installation 19 beam width: 1. horn = 19 2 horn = 1 3 horn = 10 4 horn = 8 Note: Beam angle is the width of the cone where the energy density is

More information

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview Overview Function Displays and keypad Operation of the SITRANS FUS060 transmitter can be carried out using: Keypad and display unit HART communicator PC/laptop and SIMATIC PDM software via HART communication

More information

TEK-F LEX 4100A. Guided Wave Radar Level Transmitter. LEVEL. Technology Solutions

TEK-F LEX 4100A. Guided Wave Radar Level Transmitter.   LEVEL. Technology Solutions Technology Solutions TEK-F LEX 4100A Guided Wave Radar Level Transmitter LEVEL www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction Featuring TDR (Time Domain

More information

Level Measurement With REFLEX RADAR

Level Measurement With REFLEX RADAR Reflex Radar & TDR HYC-RR03 Elect. Iss. 03 Level Measurement With REFLEX RADAR Why Radar Technology for Level Measurement? INSENSITIVE TO CHANGES IN Dielectric Pressure Vacuum Humidity Dust Viscosity Foam

More information

OPTIFLUX 5000 Technical Datasheet

OPTIFLUX 5000 Technical Datasheet OPTIFLUX 5000 Technical Datasheet Electromagnetic flowmeter in flanged version Exceptional long-term stability and accuracy For highly aggressive and abrasive fluids Fully vacuum-resistant with high-tech

More information

Level measurement Radar

Level measurement Radar Level measurement Radar Overview 6 VEGAPULS series 60 8 Dimensions 20 AL-EN - 5 Level measurement Radar VEGAPULS: Non-contact measurement of liquids and solids under arduous process conditions Measuring

More information

Level Measurement Products Installation Considerations-Radar

Level Measurement Products Installation Considerations-Radar Siemens Industry, Inc / IA / Process Instruments Level Measurement Products Installation Considerations-Radar Restricted Siemens Industry, Inc. 2015 All rights reserved. Answers for industry. Radar Measures

More information

LEVEL WITH US. to Effectively Minimize Process Upsets. 25 GHz pulse radar for liquids and slurries in general service and process applications

LEVEL WITH US. to Effectively Minimize Process Upsets. 25 GHz pulse radar for liquids and slurries in general service and process applications Lesman Instruments Valves Controls Lesman Level Products Guide Vol LEV16 Find the right fit for your level application. Look inside for level technologies that work in liquids, solids, slurries, interfaces,

More information

Digital flow transmitter for continuous flow measurement

Digital flow transmitter for continuous flow measurement Digital flow transmitter for continuous flow measurement Compact or remote version for DN 06 to 400, PN10 Shows both flow rate and volume (with two totalizers) Automatic-calibration: TEACH-IN Simulation:

More information

2-Wire. Level Gauge BM 702

2-Wire. Level Gauge BM 702 KROHNE 09/2001 7.02323.22.00 GR/PRINTO Level Gauge 2-Wire Level-Radar 2-Wire The first and only FMCW Radar Level Gauge with 2-wire technology The non-contact alternative to ageing technologies Maintenance-free

More information

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm Electronic pressure measurement Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm WIKA data sheet PE 86.05 Applications Process technology Machine building and plant

More information

OPTIFLUX 5000 Technical Datasheet

OPTIFLUX 5000 Technical Datasheet OPTIFLUX 5000 Technical Datasheet Electromagnetic flowmeter in flanged version Exceptional long-term stability and accuracy For highly aggressive and abrasive fluids Fully vacuum-resistant with high-tech

More information

DREXELBROOK. IMPULSE Series. Guided Wave Radar (TDR) Easy to install, Easy to use. Dependable performance. The New Impulse Guided Wave Radar

DREXELBROOK. IMPULSE Series. Guided Wave Radar (TDR) Easy to install, Easy to use. Dependable performance. The New Impulse Guided Wave Radar DREXELBROOK A Leader In Level Measurement Solutions IMPULSE Series Guided Wave Radar (TDR) and Volumetric for Total Level Measurements TDR Level Measurement Easy to install, Easy to use TDR Level Measurement

More information

Technologies, Solutions, and Applications. Guided Wave Radar for Level

Technologies, Solutions, and Applications. Guided Wave Radar for Level Technologies, Solutions, and Applications Guided Wave Radar for Level Contents Leadership in Guided Wave Radar 3 Principles of Operation 4 Models and Versions 5 Guided Wave Radar in the plics System 8

More information

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400 Data Sheet MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400 Submersible Hydrostatic s Rugged and versatile We reserve the right to continuously improve our products and make any change in

More information

Flow Measurement SITRANS F M. Transmitter TRANSMAG 2 with sensor 911/E 4/101. Overview

Flow Measurement SITRANS F M. Transmitter TRANSMAG 2 with sensor 911/E 4/101. Overview Siemens AG 2010 Flow Measurement Overview Design The complete flowmeter consists of a flow sensor and an associated transmitter from the TRANSMAG 2 for pulsed alternating field. These are available as

More information

Georg Fischer Piping Systems Point, Ultrasonic & Radar Level Products

Georg Fischer Piping Systems Point, Ultrasonic & Radar Level Products Georg Fischer Piping Systems Point, Ultrasonic & Radar Level Products Presented to valued clients attending the Technology Summit hosted by: Kendall Group/ J.O.Galloup +GF+ Offering Level Measurement Continuous

More information

DREXELBROOK. IMPULSE Series Guided Wave Radar (TDR) for Total Level and Volumetric Measurements. Easy to install, Easy to use. Dependable performance

DREXELBROOK. IMPULSE Series Guided Wave Radar (TDR) for Total Level and Volumetric Measurements. Easy to install, Easy to use. Dependable performance DREXELBROOK A Leader In Level Measurement Solutions IMPULSE Series Guided Wave Radar (TDR) for Total Level and Volumetric Measurements TDR Level Measurement Easy to install, Easy to use TDR Level Measurement

More information

SITRANS F flowmeters SITRANS F US. SONOFLO SONO 3000 transmitter. 4/152 Siemens FI Overview

SITRANS F flowmeters SITRANS F US. SONOFLO SONO 3000 transmitter. 4/152 Siemens FI Overview Overview Design The transmitter is available in different enclosure to fit any demands: IP67 enclosure for compact or wall mounting IP00 as a 19 insert IP65 for wall mounting IP65 enclosure in stainless

More information

Digital flow ELEMENT transmitter for continuous flow measurement

Digital flow ELEMENT transmitter for continuous flow measurement ELEMENT Transmitter Digital flow ELEMENT transmitter for continuous flow measurement Type can be combined with... PN10, DN15 to DN400 fluidic process connection Programmable outputs : one or two transistor

More information

Magnetostrictive Level Transmitter

Magnetostrictive Level Transmitter Magnetostrictive Level Transmitter Magnetostrictive Level Transmitter Overview Söm-Tek TM The SKMT liquid level transmitter satisfies the demand for an analog communication interface for sightglass (bypass

More information

ED701 General Industry Pressure Transmitter

ED701 General Industry Pressure Transmitter ED701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response

More information

Technical Information Nivector FTC968, FTC968Z

Technical Information Nivector FTC968, FTC968Z TI0007F/00/EN/7.6 7494 Products Solutions Services Technical Information Nivector FTC968, FTC968Z Capacitance Point level switch for powder and fine-grained bulk solids Application The Nivector is a small-sized

More information

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA Mobrey Ultrasonic Product Data Sheet February 215 IP245, Rev EA MSP422, MSP4RH, and MSP9GH Level Transmitters Non-contacting measurement with no moving parts Integral LCD and push-buttons as standard for

More information

SITRANS F flowmeters SITRANS F US SONOCAL /184 Siemens FI

SITRANS F flowmeters SITRANS F US SONOCAL /184 Siemens FI Overview Integration The flowmeter pulse output is often used as input for heat calculators. The range of meters enables optimum measurement of energy consumption. The analog output is used to inform the

More information

RADAR TRANSMITTERS BLISSFLEX 1100 SELECTION GUIDE. The characters of the order code have been described below

RADAR TRANSMITTERS BLISSFLEX 1100 SELECTION GUIDE. The characters of the order code have been described below BLISSFLEX 1100 The characters of the order code have been described below BA25 4 BLISSFLEX 1100 C 2-wire loop-powered 4...20 ma Guided Radar (TDR) level meter: -50...+100 C and -1...16 barg / -58...212

More information

Echotel Model 910 Ultrasonic Level Switch

Echotel Model 910 Ultrasonic Level Switch Echotel Model 910 Ultrasonic Level Switch D E S C R I P T I O N Echotel Model 910 Level Switches utilize ultrasonic contact technology for measuring level in clean liquid applications. The dual conduit

More information

Ultrasonic Liquid Level Transmitters

Ultrasonic Liquid Level Transmitters Product Data Sheet Ultrasonic Liquid Level Transmitters Non-contacting measurement with no moving parts Integral LCD and push-buttons as standard for on-site programming Continuous measurement of level

More information

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus Logic Transmitter with FOUNDATION Fieldbus Integrates Discrete I/O on a FOUNDATION Fieldbus H1 Segment Reduces Installation and Maintenance Costs with a Single Network for Analog and Discrete devices Easily

More information

ECHOTEL 961/962. Ultrasonic level switches. Loop or line powered D E S C R I P T I O N F E AT U R E S A G E N C Y A P P R O VA L S

ECHOTEL 961/962. Ultrasonic level switches. Loop or line powered D E S C R I P T I O N F E AT U R E S A G E N C Y A P P R O VA L S ECHOTEL 961/962 Ultrasonic level switches D E S C R I P T I O N The Echotel 961/962 series utilizes pulse signal technology to detect high or low level alarm(s) in a broad range of viscous to light liquids.

More information

Ultrasonic level transmitter, non-contact

Ultrasonic level transmitter, non-contact Ultrasonic level transmitter, non-contact Type 8175 can be combined with... Compact, remote versions for level measurement up to 10 m Multi language menu control Interference echo filter Automatic calibration:

More information

Intrinsically Safe Pressure Transmitter for applications in hazardous environments and shipbuilding industry Model IS-20-S, IS-21-S, IS-20-F, IS-21-F

Intrinsically Safe Pressure Transmitter for applications in hazardous environments and shipbuilding industry Model IS-20-S, IS-21-S, IS-20-F, IS-21-F Replacement product: Model IS-3 Electronic Pressure Measurement Intrinsically Safe Pressure Transmitter for applications in hazardous environments and shipbuilding industry Model IS-20-S, IS-21-S, IS-20-F,

More information

SGM LEKTRA LEVEL Measurement Control SGM LEKTRA Capacitive Ultrasonic Radiated microwave Guided Microwave Hydrostatic head Vibration Resistive

SGM LEKTRA LEVEL Measurement Control SGM LEKTRA Capacitive Ultrasonic Radiated microwave Guided Microwave Hydrostatic head Vibration Resistive level measurement LEVEL SGM LEKTRA produces level measurement instruments for industrial applications and for environmental monitoring. These instruments are divided into two groups: Measurement - Numeric

More information

INSERTION paddle wheel flowmeter for continuous flow measurement

INSERTION paddle wheel flowmeter for continuous flow measurement INSERTION paddle wheel flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both

More information

Technical Information Smartec CLD18

Technical Information Smartec CLD18 TI01080C/07/EN/02.14 71264779 Products Solutions Services Technical Information Smartec CLD18 Compact inductive conductivity measurement for the food and beverage industry Application Compact measuring

More information

FLOWMETER. Siemens MAG 5000/6000. Overview

FLOWMETER. Siemens MAG 5000/6000. Overview Overview Design The transmitter is designed as either IP67 NEMA 4X enclosure for compact or wall mounting or 19" version as a 19 insert as a base to be used in: 19" rack systems Panel mounting IP65/NEMA

More information

LST400 Ultrasonic level / open channel flow transmitter

LST400 Ultrasonic level / open channel flow transmitter Data sheet DS/LST400 EN Rev.C LST400 Ultrasonic level / open channel flow transmitter Measurement made easy Reduced installation cost Easy access terminations Integrated echo display makes for easy troubleshooting

More information

Rosemount 3101, 3102, and 3105

Rosemount 3101, 3102, and 3105 Product Data Sheet February 2013 00813-0100-4840, Rev DA Rosemount 3101, 3102, and 3105 Ultrasonic Liquid Level Transmitters Non-contacting measurement with no moving parts Integral LCD and buttons as

More information

LST100 Ultrasonic level transmitter for upstream oil and gas

LST100 Ultrasonic level transmitter for upstream oil and gas Data sheet DS/LST100-EN LST100 Ultrasonic level transmitter for upstream oil and gas Accurately track and measure the most expensive consumable on your site chemicals. Measurement made easy Features Keep

More information

SITRANS F C. Flowmeter SITRANS FC430 3/151. Technical specifications. Overview

SITRANS F C. Flowmeter SITRANS FC430 3/151. Technical specifications. Overview Flow Measurement Flowmeter SITRANS FC40 Overview The complete flowmeter system SITRANS FC40 can be ordered for standard, hygienic or NAMUR service. All versions can be ordered for CT service, according

More information

SITRANS T measuring instruments for temperature

SITRANS T measuring instruments for temperature Overview Our field devices for heavy industrial use HART, Universal 4 to 20 ma, universal Field indicator for 4 to 20 ma signals The temperature transmitter SITRANS TF works where others feel uncomfortable.

More information

Technologies, Solutions, and Applications. Level Switching

Technologies, Solutions, and Applications. Level Switching Technologies, Solutions, and Applications Level Switching Contents Leadership in Level Switching 3 How We Earn Your Business 4 Models & Versions 5 About Level Switching 11 Assurance with Redundant Systems

More information

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751 Data sheet Intrinsically safe pressure transmitter MBS 420, MBS 425, MBS 470 and MBS 475 The intrinsically safe pressure transmitter program is designed for use in hazardous environments and offers a reliable

More information

Features. NULL-KOTE Circuitry Makes the sensor immune to adverse effects of conductive coating build up.

Features. NULL-KOTE Circuitry Makes the sensor immune to adverse effects of conductive coating build up. Model L2610 Instrumentation designed with the user in mind. NULL-KOTE Self-Diagnostic Analog Level Transmitter Electronic, RF Impedance sensing, with the innovative NULL-KOTE system, which ignores product

More information

Level gauges Series LT Level indicator, switch and transmitter for liquids

Level gauges Series LT Level indicator, switch and transmitter for liquids Level gauges Series LT Level indicator, switch and transmitter for liquids Simple construction Resistant under extreme temperature and pressure conditions No risk of leakage Excellent chemical resistance

More information

Digital flowmeter for continuous flow measurement

Digital flowmeter for continuous flow measurement 8025 Flowmeter INSERTION Digital flowmeter for continuous flow measurement Compact or remote version for DN06 to DN400, PN10 Displays both flow rate and volume (with two totalizers) On site calibration

More information

process measurement solutions Mobrey MSP IP wire 24V loop powered ultrasonic level transmitters

process measurement solutions Mobrey MSP IP wire 24V loop powered ultrasonic level transmitters process measurement solutions Mobrey MSP 2 wire 24V loop powered ultrasonic level transmitters IP2045 MSP Advanced ultrasonics This new family of ultrasonic non-contacting liquid level transmitters is

More information

Positioner with HART Communication Type 3780

Positioner with HART Communication Type 3780 Positioner with HART Communication Type 780 Application Single-acting or double-acting positioner for attachment to pneumatic control valves. Supplied with an electric input signal from to 20 ma Travels

More information

d = c 10/20/2017 Level Measurement Transmitters Applying Level Measurement p C T 273K Ultrasonic The Principle Time of Flight (TOF)

d = c 10/20/2017 Level Measurement Transmitters Applying Level Measurement p C T 273K Ultrasonic The Principle Time of Flight (TOF) Products Solutions Services Level Measurement Transmitters Applying Level Measurement Ultrasonic FDU95 FDU93 FDU92 FDU91 FDU90 Slide 1 Slide 2 The Principle Time of Flight (TOF) Emission of ultrasound

More information

ABB MEASUREMENT & ANALYTICS DATA SHEET. Ultrasonic level LST400 Open channel flow transmitter

ABB MEASUREMENT & ANALYTICS DATA SHEET. Ultrasonic level LST400 Open channel flow transmitter ABB MEASUREMENT & ANALYTICS DATA SHEET Ultrasonic level LST400 Open channel flow transmitter 2 ULTRASONIC LEVEL LST400 / OPEN CHANNEL FLOW TRANSMITTER DS/LST400 EN REV. D Measurement made easy Reduced

More information

SALES SERVICE +358 (0)

SALES SERVICE +358 (0) SALES SERVICE +358 (0)17 262 3555 info@econosto.fi ADCATROL ELECTRO-PNEUMATIC POSITIONERS PE 986 (ATEX) DESCRIPTION The ADCATROL PE986 positioner requires an input signal of 4 20 ma for proportional control

More information

3DLevelScanner. Technical Data Sheet. Level Sensor. Non-Contact, Multiple-Point Measurement

3DLevelScanner. Technical Data Sheet. Level Sensor. Non-Contact, Multiple-Point Measurement Technical Data Sheet Non-Contact, Multiple-Point Measurement The 3DLevelScanner is a noncontact, dust-penetrating bin measurement device that detects irregular surfaces in powder or solid materials and

More information

6GHz Intelligent Radar Level Meter Product Manual. Model:KRD520 SERIES

6GHz Intelligent Radar Level Meter Product Manual. Model:KRD520 SERIES 6GHz Intelligent Radar Level Meter Product Manual Model:KRD520 SERIES Directory 1 Product Overview...1 2 Product Introduction...2 3 The Installation Requirements...4 4 The Electrical Connection...6 5 Instrument

More information

Flow Technologies Overview. For internal use only / Siemens AG All Rights Reserved.

Flow Technologies Overview. For internal use only / Siemens AG All Rights Reserved. Flow Technologies Overview Mag Flow MAGFLO Program Siemens offers a comprehensive selection of electromagnetic flow meters Water & waste water Chemical Food & beverage Mining Aggregates Cement Pharmaceutical

More information

Digital flow ELEMENT transmitter for continuous flow measurement

Digital flow ELEMENT transmitter for continuous flow measurement Digital flow ELEMENT transmitter for continuous flow measurement Type 8036 can be combined with... DN06 to DN65 fluidic process connection Programmable outputs : one or two transistor output(s) and single

More information

Effective Solids Level Measurement with Radar

Effective Solids Level Measurement with Radar Effective Solids Level Measurement with Radar High frequency radar such as SITRANS LR460 is the recommended level measurement technology for longrange, dusty applications. Why high frequency radar is the

More information

Main features. Operation. LEVEL Transmitters

Main features. Operation. LEVEL Transmitters Non-contact microwave level transmitters pilotr GNRAL DSCRIPTION The 25 GHz (-band) Pulse Radars are regarded as the most progressive non-contact level transmitters of the industrial process automation

More information

Coriolis Massflowmeter

Coriolis Massflowmeter Coriolis Massflowmeter for liquids and gas measuring monitoring analysing Measuring range: 0-0.8 kg / h 0-65 000 kg / h water Accuracy: ± 0.1 of reading ±zero-point stability (liquids) pmax: PN40 tmax:

More information

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

Digital flowmeter for continuous flow measurement

Digital flowmeter for continuous flow measurement 8025 Flowmeter INSERTION Digital flowmeter for continuous flow measurement Compact or remote version for DN06 to DN400, PN10 Displays both flow rate and volume (with two totalizers) On site calibration

More information

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted Electrical temperature measurement Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted WIKA data sheet TE 60.34 Applications Machine building, plant and vessel construction

More information

Valve Island with Electronic I/O

Valve Island with Electronic I/O Screw in Temperature /Switch with display for ON/OFF Control Indication, monitoring, transmission and ON/OFF control in one device Extra large display Menu guided parametrisation Complete communication

More information

Mid-West. Instrument. Model 140 Electrical Installation and Operating Instructions. Gauge Front ELECTRICAL

Mid-West. Instrument. Model 140 Electrical Installation and Operating Instructions. Gauge Front ELECTRICAL Mid-West Instrument BULLETIN NO. ELEC-IM140/11A Replaces ELEC-IM140-141/09A ELECTRICAL Gauges with switches have one or two SPST or SPDT hermetically sealed adjustable set point reed switch assemblies.

More information

Electromagnetic Flow Transmitter

Electromagnetic Flow Transmitter Electromagnetic Flow Transmitter Sensor in solid state technology Working as a transmitter and/or as an On/Off controller Automatic-calibration of full scale: Teach-In Clean in place (CIP) Type can be

More information

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

Indholdsmåling Dalum Landbrugsskole Vejeevent 21. august 2018

Indholdsmåling Dalum Landbrugsskole Vejeevent 21. august 2018 Indholdsmåling Dalum Landbrugsskole Vejeevent 21. august 2018 Siemens.com/level Indholdsmåling Page 2 Level Signal Indholdsmåling Two groups of level measurement: Continuous measurement of material at

More information

Kotron Model 82 CE RF Level Transmitter

Kotron Model 82 CE RF Level Transmitter Kotron Model 82 CE RF Level Transmitter DESCRIPTION The Kotron Model 82 RF Capacitance transmitter is one of the most cost effective level transmitters available today. Compact in size, it employs state-of-the-art

More information