PR product range - links to order details and block diagrams

Size: px
Start display at page:

Download "PR product range - links to order details and block diagrams"

Transcription

1 PR product range links to order details and block diagrams PR product range links to order details and block diagrams MTS Messtechnik Schaffhausen GmbH Mühlenstrasse 4, CH8260 Stein am Rhein Telefon Telefax Messen Prüfen Automatisieren

2 Order: 2202 Type Input Output Supply Range 2202 Pt100 : L Spec. : 0 24 DC : D Acc. to order Ni100 : N ma : AC & : P Lin. R : R ma : DC Spec. : X ma : : : : : 7 For 2wire connection pin 6 and 7 must be shortcircuited in the socket. JP1 ON JP2 ON oltage output: 0/ DC 0/ DC Shortcircuit pins 3 and 2, = 2, = 1

3 Order : 2204 Type Input Output Supply ma : A Special : 0 24 DC : D ma : B ma : AC & : P : C ma : DC : D ma : : E : : F : 5 Special : X : : 7 Programming: INPUT DP1 (10pole) PROGRAMMING SW 1, 2, 3, 4, 5 SW ON SW OFF ma 1, 3 2, 4, ma 1, 4 2, 3, , 3 1, 4, , 4 1, 3, , 3, 4 1, 5 For 20% offset on input, set DP1 SW5 ON e.g. input ma 1, 4, 5 2, 3 OUTPUT DP2 (4pole) DP1 (10pole) PROGRAMMING SW 1 4 SW 6, 7, 8, 9, 10 SW ON SW OFF ON OFF ma 4 1, 2, 3 7 6, 8, 9, ma 3 1, 2, 4 8 6, 7, 9, ma / m 1, 4 2, 3 6 7, 8, 9, ma / , 3 2, 4 6, 7 8, 9, ma / , 4 1, 3 6, 8 7, 9, ma / , 3 1, 4 6, 7, 8 9, 10 For 20% offset on output, set DP1 SW9 ON e.g. output ma 3 1, 2, 4 8, 9 6, 7, 10 For reversed output set DP1, SW10 ON e.g. output ma 3 1, 2, 4 8, 9, 10 5, 6, 7 Note: At other spans than the abovementioned, DP1 and DP2 have a different setting which applies to the delivered special range.

4 Order: 2220 Type ersion AC : A 230 AC : B 24 AC : D 120 AC : F Output Special ( ) : 0 24 DC : 1 15 DC : 2 12 DC : 3 5 DC : 4

5 Order : 2222 Type Input AC : A 230 AC : B Output 24 DC : 1 15 DC : 2

6 Order: 2223 Type ersion AC : A Output 1 Special ( DC) : 0 Output 2 Special ( DC) : AC : B 24 DC : 1 24 DC : 1 24 AC : D 15 DC : 2 15 DC : 2 12 DC : 3 12 DC : 3 5 DC : 4 5 DC : 4 Connection diagram: Serial connection / supply Serial connection or () 10 48DC DC DC (GND) GND DC GND ( DC) 2 different pos. supplies with common ground 2 different neg. supplies with common ground DC 9 GND GND DC DC GND 8 GND DC

7 Order: 2224 Type Input range Supply Option ma : A 12 : 1 Single valve (A) : A ma : B 24 : 2 Double valve (A/B) : B : C : D : E : F ±10 potentiometer : G potentiometer : H Timing diagram:

8 Order: 2229 Type ersion 2229 AC or DC : A Output Special ( ) : 0 24 DC : 1 15 DC : 2 12 DC : 3 5 DC : 4

9 Order: 2231 Type Supply DC : D AC : P DC Hardware programming: Input: Input JP1 JP madc I ARMS I I DC RMS Output: Relay JP position Relay 1 normally open JP 2 N.O. Relay 1 normally closed JP 2 N.C. Relay 2 normally open JP 3 N.O. Relay 2 normally closed JP 3 N.C.

10 Order : 2237 Type Input Output Setpoint ma : A ma : B : C : D : E spec. : X Active at increasing input : 1 Active at decreasing input : 2 Setp. notch opr. : A Setp. knob opr. : B Programming: Input and function DP1 ON DP2 ON ma 1, ma 1, , , 4 6 Active relay at: Increasing input signal 1, 3 Decreasing input signal 2, 4 For safe operation, all other switches must be OFF.

11 Order: 2238 Type Input Output Setpoint ma : A 2 x active at increasing input : ma : B 2 x active at decreasing input : : C Active at decreasing input : D at increasing input 2 : : E Active at decreasing input 2 at increasing input 1 : 4 spec. : X Hold rel. 2 : 5 Setp. notch opr. : A Setp. knob opr. : B Programming: Input and function DP1 ON DP2 ON ma 1, ma 1, , , 4 Active relay 1 at: Increasing input signal 5, 7 Decreasing input signal 6, 8 Active relay 2 at: Increasing input signal 1, 3 Decreasing input signal 2, 4 Relay 2 hold 5 Relay 1 failsafe 7 Relay 2 failsafe 6 For safe operation, all other switches must be OFF.

12 Order : 2240 Type Input Output AC : A Special : AC : B 24 AC : 1 Special : X 12 AC : 5 Maximum power output:

13 Order: 2241 Type Input Output Setpoint ma : A ma : B : C : D : E spec. : X 2 x active at increasing input : 1 2 x active at decreasing input : 2 Active at decreasing input 1 and at increasing input 2 : 3 Active at decreasing input 2 and at increasing input 1 : 4 Hold relay 2 : 5 Setp. notch opr. : A Setp. knob opr. : B Relay Rel. 1 N.O., Rel. 2 N.O. : 1 Rel. 1 N.O., Rel. 2 N.C. : 2 Rel. 1 N.C., Rel. 2 N.O. : 3 Rel. 1 N.C., Rel. 2 N.C. : 4 Programming: Jumper position JP1 N.O. Rel. 1 normally open JP1 N.C. Rel. 1 normally closed JP2 N.O. Rel. 2 normally open JP2 N.C. Rel. 2 normally closed Input and function DP1 ON DP2 ON ma 1, ma 1, , , 4 Active relay 1 at: Increasing input signal 5, 7 Decreasing input signal 6, 8 Active relay 2 at: Increasing input signal 1, 3 Decreasing input signal 2, 4 Rel. 2 hold 5 Rel. 1 failsafe 7 Rel. 2 failsafe 6 For safe operation, all other switches must be OFF.

14 Order: 2255 Type ersion Output 2255 Fixed : A Analogue NPN output : 1 Programmable : B Analogue relay output : 2 Analogue output programming: Output range JP3 JP2 JP ma (current only) OFF ma (current only) ON ma / OFF OFF ON ma / ON OFF ON ma / OFF ON OFF ma / ON ON OFF Special voltage output: ON or (Resistor R38 mounted) OFF OFF OFF

15 Order: 2261 Hardware programming: JP1 JP2 Output MENU 4.3 range OFF OFF ma ma 002 ON OFF m m 004 OFF ON

16 Order : 2271 Type Input Output Relay action Setpoint 2271 Pt100 : L Spec. : 0 At increas. input : A Setpoint knob : 1 Ni100 : N ma : 1 At decreas. input : B Setpoint notch : 2 Lin. R : R ma : 2 Spec. : X ma : 3 For 2wire connection, pin 6 and 7 must be shortcircuited in the socket.

17 Order : 2273 Type Input Output Range 2273 Pt100 : L ma : 2 Acc. to order Ni100 : N Lin. R : R Spec. : X For 2wire connection, pin 6 and 7 must be shortcircuited in the socket. Standard ranges Pt C C C C C C C C C C C C

18 Order: 2279 Type Input Output Supply RMS : A Special : 0 24 DC : D RMS : B ma : AC & : P RMS : C ma : DC (0...4 peak) : RMS : D : RMS : E : RMS : F : ARMS : G ARMS : H Special : X Programming: INPUT DP1 (8pole) JP1 PROGRAMMING SW 1, 2, 3, 4, 5 POSITION SW ON SW OFF RMS 1, 2, 3, 4, 5 X RMS 5 1, 2, 3, 4 X RMS 4 1, 2, 3, 5 X RMS 2, 4, 5 1, 3 X RMS 1, 2, 3 4, 5 X RMS 1, 2, 3, 5 4 X ARMS 3, 4 1, 2, 5 X ARMS 3, 4, 5 1, 2 X OUTPUT DP2 (4pole) DP1 (8pole) PROGRAMMING SW 1 4 SW 6, 7, 8 SW ON SW OFF ON OFF ma 3 1, 2, 4 6 7, , 3 2, 4 7 6, , 3 1, 4 6, 7 8 For 20% offset on output, set DP1 sw. 8 ON, e.g. output ma 3 1, 2, 4 6, 8 7 Note: At other spans than the abovementioned, DP1, DP2, and JP1 have a different setting which applies to the delivered special range.

19 Order : 2281 HARDWARE PROGRAMMING: JP1 JP2 JP3 Output MENU 4.3 OFF OFF OFF ma 1 ON ma 2 ON OFF OFF m 3 ON m 4 OFF ON OFF ON

20 Order: 2284 Type Input Output Supply Output type ma : A ma : B : C : D : E : F : G : H Special : X Special : ma : ma : ma : : : : : : 8 24 DC : D AC & : P DC Standard : 1 Buffered voltage : 2 T 2wire transm. JP 2 Universal sup. only 2wire supply / 7 Loop supply 1 9 Supply (), (P) 2.5 ref ref Or AC & DC DC 3wire potm. Input Input gnd. ma JP DP1 DP CPU 2284 DP2 output offset 9 10 DP2 100% 0% DP ma Buffer 3 1 Output type DP2 DP I Supply (gnd), (N) I Out Gnd. A Out I Out A INPUT DP1 (10pole) JP1 PROGRAMMING SW 1, 2, 3, 4, 5, 6 POSITION SW ON SW OFF ma 1, 2, 3 4, 5, 6 X ma 1, 2, 3, 4 5, 6 X m 1, 2, 3, 4, 5, 6 X m 4 1, 2, 3, 5, 6 X , 2, 4, 5, 6 X , 4 1, 2, 5, 6 X , 3, 4, 5, 6 X , 4 1, 3, 5, 6 X For 20% offset on input, set DP1 SW5 ON e.g. input ma 1, 2, 3, 4, 5 6 X For bipolar input set DP1, SW6 ON e.g , 6 1, 3, 4, 5 X OUTPUT DP1 (10pole) ** DP2 (10pole) PROGRAMMING SW 7, 8, 9, 10 SW 1, 2, 6, 7, 8, 9, 10 SW ON SW OFF ON OFF ma 8 7, 9, 10 6, 7 1, 2, 8, 9, ma 7 8, 9, 10 6, 8 1, 2, 7, 9, ma / m 8 7, 9, 10 1, 6, 7 2, 8, 9, ma / , 9, 10 1, 6, 8 2, 7, 9, ma / , 9, 10 2, 6, 7 1, 8, 9, ma / , 9, 10 2, 6, 8 1, 7, 9, 10 For 20% offset on output, set DP1 SW9 ON, DP2 SW9 and SW10 ON, e.g. output ma 7, 9 8, 10 6, 8, 9,10 1, 2, 7 For reversed output set DP1, SW10 ON e.g. output ma 7, 9, , 8, 9,10 1, 2, 7 ** DP2 SW 6 is ON and SW 3, 4, 5 are OFF, except for buffered output Note: At other spans than the ones mentioned in the table and at a buffered voltage output, DP1, DP2, JP1, and JP2 have a different setting which applies to the delivered special range. The buffered voltage output cannot be programmed acc. to the above programming table, but will be delivered fullyconfigured from factory.

21 Order: 2285 Type Channels channel : A 2 channels : B Load schedule:

22 Order : 2286 Type Input 2286 oltage / current : A Temperature : B Input : A ref. Input (setp., Bch) Input gnd DC JP 1 50 PGA reg. A / D e CPU Neutral DC DC Rel. 1 Up Supply 24DC Supply gnd. Rel. 1 N.O. Relay common Input (proc., Ach) Input gnd. 2 1 JP 2 50 PGA A / D EEPROM 2286A Rel. 2 Down 5 Rel. 2 N.O. Input : B ref. Input (setp., Bch) Input gnd DC JP 1 50 PGA 1.25 ma reg. A / D e CPU Neutral DC DC Rel. 1 Up Supply 24DC Supply gnd. Rel. 1 N.O. Relay common Comp. 1 Pt100 Input 2 PGA A / D EEPROM Rel. 2 Down 5 Rel. 2 N.O. Input 3 ref. 2286B Hardware programming: INPUT: Channel A ma JP2 ON MENU 2.3 = I DC JP2 OFF MENU 2.3 = U Channel B ma JP1 ON MENU 3.3 = I DC JP1 OFF MENU 3.3 = U

23 Order: 2288 Type Sensor Input filter Trig Output pulse width 2288 Tacho : A Spec. : 0 Trailing edge : A Spec. : 0 Direct Output : A NAMUR : B > 10 ms : 1 Leading edge : B Direct : 1 Inverse : B NPN : C (max. 50 Hz) Adjust. : 2 PNP : D None : 2 ( ms) TTL : E Fixed (50 ms) : 3 S0 : F Spec. : X Programming: JUMPER PROGRAMMING ON OFF Trailing edge JP1 JP2 Leading edge JP2 JP1 Pulse width 1:1 JP3 JP4, JP5 Pulse width fixed 50 ms JP5 JP3, JP4 Pulse width adjustable JP4 ON and JP3, JP ms JP9 in pos ms JP9 in pos. 12 Direct output JP6 in pos. 12 Inverse output JP6 in pos. 23 NAMUR supply JP7 in pos. 12 S0 supply JP7 in pos. 23 Active output JP8 in pos. 12 Normal output JP8 in pos. 23 DP1: INPUT TYPE INPUT ON OFF Tacho 5 1,2,3,4,7 NAMUR 3,5 1,2,4,7 and JP7 in 12 NPN 1 2,3,4,5,7 PNP 2 1,3,4,5,7 TTL 4 1,2,3,5,7 S0 (DIN 43864) 3,6,7 1,2,4,5 and JP7 in 23 Input filter: > 10 ms/max. 50 Hz 6 Sensor Trig level Input resistance TL TH Tacho 200 m 350 m > 100 kω NAMUR 1.2 ma 2.1 ma NPN, PNP kω TTL > 100 kω S0 input 2.2 ma 9.0 ma

24 Order : 2289 Type Inputs 2289 Current / voltage : A Pt100 & Current / voltage : B Hardware programming: INPUT: Channel A ma JP4 ON MENU 2.3 = I DC JP4 OFF MENU 2.3 = U Channel B ma JP3 ON MENU 3.3 = I DC JP3 OFF MENU 3.3 = U NPN JP6 ON PNP JP6 OFF OUTPUT: Output JP1 JP2 JP5 MENU ma OFF OFF OFF ma ON m ON OFF OFF m ON OFF ON OFF ON 6

25 Order: 2914 Type Measurement range C : A Output Special : 0 Sensor error value To max., 23 ma : A C : B ma : 2 To min., 3.8 ma : B Special : X ma : 9 Special : X

26 On the front of the box : A Order : 3532 On top of the box : B On the left side of the box : C On the rear of the box : D (See mechanical specs. below) : Type Input Encoder placement Limit switch 3532 Internal encoder : 0 External encoder : 1 (Specify cable length) On the front of the box : A / AC/DC : 2 On top of the box : B On the left side of the box : C On the rear of the box : D (See mechanical specs. below) : Mechanical specifications: External encoder: Application:

27 Order codes: 4114 = Universal transmitter 4501 = Display / programming front 2wire transmitter Current oltage Potentiometer RTD and lin. R, connection, wires TC ma Supply AC or DC Supply CJC PTC MUX A / D CPU Safety D / A I ma 10 1 ma 10 Ω Green EEPROM Red 500Ω 50Ω 11 Gnd. I Out. I Out. Out. 4114

28 Order codes: 4116 = Universal transmitter 4501 = Display / programming front 2wire transmitter Current oltage Potentiometer RTD og lin.r, connection, wires TC ma Supply AC or DC Supply MUX A / D CPU D / A I 10 ma 41 CJC Safety 13 1 ma 1 2 PTC 10 Ω Green EEPROM Red Yellow 500Ω 50Ω Gnd. I Out. Relay 2 Relay 2 I Out. Out Yellow Relay 1 Relay 1

29 Order codes: 4131 = Universal trip amplifier 4501 = Display / programming front 2wire transmitter Current oltage Potentiometer RTD and lin. R, Connection, wires TC ma Supply AC or DC Supply MUX A / D CPU 41 CJC PTC Ω Green EEPROM Yellow Yellow Relay 2 Relay 2 Relay 1 21 Relay

30 Order: 5102 Type Channels channel : A 2 channels : B For 2wire connection, shortcircuit pin 42 and 43, (52 and 53).

31 DIPswitch programming: Factorycalibrated standard ranges: When special measurement ranges are delivered, all DIPswitches for the channel in question are OFF.

32 Order : 5105B Type Input Output Channels Single : A Double : B 5105B 0 20 ma : A 4 20 ma : B 0 10 : E 2 10 : F Special : X Special : ma : ma : : : : : 7 DiIPswitch programming: Factorycalibrated standard ranges: When special measurement ranges are delivered, all DIPswitches for the channel in question are OFF.

33

34

35 Order : 5114 Type ersion Input Channels 5114 Single : A [EEx ia] IIC : B RTD / TC / m / R ma / / m Channel 1, RTD / TC / m / R Channel 2, ma / / m : 1 : 2 : 3 Double : B Standard : A RTD / TC / R / ma / / m : Note! For TC inputs with internal CJC, remember to order the CJCterminals type 5910 / 5910 EEx (ch. 1) and 5913 / 5913 EEx (ch.2). Channel 1 shown as a temperature input: m m T RTD and lin. R Conn. wire 4 3 2!! If channel 2, use terminal no Channel 2 shown as a current / voltage input: 2wire transm. 3wire potm. ma TC * Loop supply / ref. > 2.5!! If channel 1, use terminal no Input, > 2.5 Input Input gnd. <= 2.5 Selection of input type: (5114A) Temperature channel 1 Temperature channel 2 * Accessories: 5910 CJC connector CH 1, 5913 CJC connector CH 2. CH JP 2 JP CH 2 5 M JP PTC 0,2 ma Analogue Switch 5 M MUX JP PTC 0,2 ma Analogue Switch MUX 10 Ω 10 Ω 50 k PGA 50 k PGA Input JP 1 JP 2 JP 3 JP reg A / D Channel 1 reg. 2.5 A / D Channel 2 Front comm. Loop sup. > 18 Loop sup. > 18 CPU EEPROM D / A Spec. Output 1 D / A Spec. Output 1 13 A DP DP Supply AC & DC Supply 2wire output sup. 2wire output sup. A ma I GND. I gnd. I Out A A I Out A I Out A ma I Out Out 2wire output sup. 2wire output sup. Out Current / voltage channel 1 Current / voltage channel

36 Order: 5115 Type 5115 ersion Standard ATEX Ex : A : B Input RTD / TC / m / R / ma / : _ RTD / TC / m / R : 1 ma / / m : 2 Input 1, RTD / TC / m / R Input 2, ma / / m : 3 *NB! Please remember to order CJC connectors type 5910EEx (input 1) and 5913EEx (input 2) for TC inputs with an internal CJC. Selection of input type: (5115A) Temperature input 1 Temperature input 2 Input JP 1 JP 2 JP 3 JP Current / voltage input 1 Current / voltage input

37 Order: 5116 Type ersion 5116 Standard : A ATEX Ex and FM.... : B *NB! Please remember to order CJC connectors type 5910/5910EEx for TC inputs with internal CJC * Accessories: CJC connectors type 5910 / 5910 EEx Bipolar m Tx 2wiretransm. RTD and lin. R, connection, wires wire potm. >= 2.5 TC * 2wire supply / 2.5 ref. Current Input, > 2.5 Input Input gnd. <= Ex barrier, only 5116B Ex barrier, only 5116B 5 M PTC 50 k 0.2 ma MUX 10 Ω 2.5 Electronic contact reg. PAG Front button, sw 1 2wire supply A / D Green CPU EEPROM 5116 Front comm. Electronic contacts Yellow Yellow D / A 50 Ω 500 Ω Supply AC or DC Supply 2wire supply 2wire supply ma ma I Gnd. ma ma I I Out. Out. Relay 2 Relay 2 Relay 1 Relay 1 Out.

38 Order: 5131 Type ersion Input Channels 5131 Single : A [EEx ia] IIC : B RTD / TC / m / R ma / / m Channel 1, RTD / TC / m / R Channel 2, ma / / m : 1 : 2 : 3 Double : B Standard : A RTD / TC / R / ma / / m : Note! For TC inputs with internal CJC, remember to order the CJC connectors type 5910 / 5910 EEx (ch. 1) and 5913 / 5913 EEx (ch. 2). Selection of input type: (5131A) Temperature channel 1 Temperature channel 2 Input JP 1 JP Current / voltage channel 1 Current / voltage channel 2 2 2

39 Order : 5132 Type ersion 5132 Standard : A Channels 1 channel : 1 2 channels : 2 CH 1 13 supply 2Wire Transmitter ma Loop supply Is Ic 12 test A CH supply A ma

40 Order: 5133 Type Channels channel : A 2 channels : B For 2wire connection, shortcircuit pin 42 and 43, (52 and 53).

41 Block diagram, 5202B1 & B2: Block diagram, 5202B4: Jumper programming:

42 DIPswitch programming:

43 Order: 5223 Type ersion Output 5223 Standard : A Analogue NPN / PNP : 1 [EEx ia] IIC : B Analogue Relay output : 2 Front comm. Input gnd. Sup. Sup. PNP NPN Contact Tacho Namur S0 Input f in DC reg. reg. 42 f in Error Dig.out 1 Dig. out 2 x relay or 2 x NPN / PNP Supply Supply AC DC Relay N.O. or PNP/NPN Dig. out 1 Relay N.O. / Dig. gnd. Relay N.O. or NPN/PNP Dig. out 2 Input gnd S f in 2 f in 2 Dig.out ma JP 1 JP I 12 Relay N.O. / Dig. gnd. I Out A Out I Out A Sup. PNP Sup. NPN Contact Tacho Namur Input A Gnd. Front comm. 8 Contact Namur Input 43 f in 1 Ex Barrier 8 DC reg. 42 f in Error Dig.out 1 Dig. out 2 x relay or 2 x NPN / PNP Supply Supply AC DC Relay N.O. or PNP/NPN Dig. out 1 Relay N.O. / Dig. gnd. Relay N.O. or NPN/PNP Dig. out 2 8 Contact Namur Input 53 f in 2 52 Ex Barrier f in 2 Dig.out B ma JP 1 50 JP I Relay N.O. / Dig. gnd. I Out Gnd. A Out I Out A

44 Order : 5225 Type ersion Output 5225 Standard : A Analogue NPN / PNP : 1 Analogue relay output : 2 Input gnd Front comm DC reg. Error Option Supply 24 DC Supply gnd. Relay 2 Sup. PNP Sup. NPN S0 Contact Tacho Namur Input 42 f in Dig out Relay 2 / PNP Relay 1 / NPN NPN pull up: 6.7 ma: JP4 ON 1.7 ma: JP3 ON 3k48 13k3 NPN JP 3 JP 4 Dig out 1 D/A 0 20 ma JP 1 JP I 12 Relay 1 / dig. gnd. I Out A Out I Out A 24 DC 5225 Spec. Out Gnd.

45 Order: 5331 Type ersion Ambient temperature Galvanic isolation 5331 Standard : A 40 C 85 C : AC : B ATEX : B FM and ATEX : C CSA, FM and ATEX : D

46

47

48

49

50

51 Order : 5420B Type Channel 5420B Double : 2

52 Order: 5514 Type Display Input Supply 5514 LED : A RTD/TC/m/R : AC : A m//ma : AC : B 24 DC / 24 AC : D 5514A1 Note: For TC inputs with internal CJC, remember to order the CJC connector type Communication 32 Supply m RTD, lin. R Conn. wire TC ma Only supply: D ~ Or Or AC AC Supply m * MUX PGA A / D CPU RE 1 RE Relay 1 22 Relay 1 EEPROM 23 Relay A1 24 Relay A2 * Accessories: 5914 CJC connector. Communication T 2wire transm. > 2.5 Loop sup. > 20 Input, > 2.5 ma Input Input gnd. <= M 50 k PTC 10 Analogue switch MUX PGA reg. A / D CPU EEPROM RE 1 RE 2 Only supply: D Supply 24 ~ Or Or AC AC Supply Relay 1 Relay 1 Relay A2 24 Relay 2

53 Order: 5515 Type Display Input Supply 5515 LED : A RTD/TC/m/R : AC : A LCD : B m//ma : AC : B 24 DC/24 AC : D Note: For TC inputs with internal CJC, remember to order the CJC terminal type Input: 1 Communication 32 Supply m RTD and lin. R Conn. wire TC ma Only supply : D ~ Or Or AC AC Supply m * MUX PGA A / D CPU 41 EEPROM 5515_1 * Accessories: 5914 CJC connector. Input: 2 Communication T 2wire transm. > 2.5 Loop supp. > 20 Input, > 2.5 ma Input Input gnd. <= M 50 k PTC 10 Analogue switch MUX PGA reg. A / D CPU EEPROM Only supply : D Supply Or Or AC AC ~ Supply 5515_2

54 Order: 5531 Type ersion Field enclosure 5531 Standard : A Type 8501 ATEX Ex : B None : 8501 / EEx nl IIC : / EEx ib IIC : 2 input ma Ex circuit input 1 Only version: B DP 1 2 A / D CPU 1 DP Backlight EEPROM Front buttons Programming: DP 1 Front keyboard SW ON SW OFF DP 1 Backlight SW ON SW OFF Keys locked 1 Off 2 Keys NOT locked 1 Half intensity 3 2 Full intensity 2, 3

55 Order: 5714 Type ersion 5714 Standard : A 2 relays : B Analogue output : C Analogue output and 2 relays : D NB! Please order the splashproof cover seperately. Order no

56 Order: 5715 Type ersion relays : B Analogue output and 4 relays..: D Tx 2wire supply > 15 DC ma PC communication Supply AC or DC Supply Input, ma 45 PTC ersion D 12 I ma Potm. RTD, wires Ω AD CPU R1 R Gnd. I Output Common Relay 1 N.O. Relay 1 N.C. Common Relay 2 N.O. Relay 2 N.C TC Input gnd. 43 Int. CJC EEPROM 5715 R3 R Common Relay 3 N.O. Relay 3 N.C. Common Relay 4 N.O. Relay 4 N.C.

57

58 Order: 6331 Type ersion Galvanic isolation Channels 6331 Standard : A 1500 AC : 2 Single : A ATEX Ex : B Double : B *NB! Please remember to order CJC connectors type 5910 / 5910EEx (channel 1) and 5913 / 5913EEx (channel 2) for TC inputs with an internal CJC. * Internal CJC connector must be ordered separately. m RTD, lin. R wire TC CH ma 13 Supply m * MUX PGA A / D CPU EEPROM 6331 Comm. D / A ma Ex circuit, only 6331B 11 Supply ma ma CH

59 Order: 6333 Type ersion Galvanic isolation 6333 Standard : A None : 1 EEx : B Channels Single Double : A : B

60 Order: 6334 Type ersion Galvanic isolation Channels 6334 Standard : A 1500 AC : 2 Single : A ATEX Ex : B Double : B

61

62

63 Order: 7101 Type Modules : A 16 : B Output connector I Specify : : 56p. Elco connector : : 37p. SUB D connector : : 2x16p. terminal block : : 50p. SUB D connector : : 34p. 3M flat cable : : 25p. SUB D connector : 6 None : 9 Output connector II Specify : : 56p. Elco connector : : 37p. SUB D connector : : 2x16p. terminal block : : 50p. SUB D connector : : 34p. 3M flat cable : : 25p. SUB D connector : 6 None : 9 NB: Accessory for 16 module backplane: 2x2x16pole terminal block type 7205 mounted on assembly board. Please remember to order Ex division plate type 7301 for backplanes featuring both Ex and non Ex modules.

64 Bestillingsskema: 7400 Type Pt100 elementer Nøjagtighed Kølehals Indstikslængde x Pt100 : A Klasse A : 1 Ingen : A 50 mm : 1 2 x Pt100 : B 100 mm : B 100 mm : mm : C 150 mm : mm : D 200 mm : mm : mm : 6 Ordreeksempel: 7400A1A2 = 1 x Pt100 element Klasse A nøjagtighed Ingen kølehals 100 mm indstikslængde Målskitse:

65 Order: 8501 Picture: Type Cable glands cable gland : A 2 cable glands : B 3 cable glands : C 4 cable glands : D

2-WiRE LEvEL TRansmiTTER PRELEvEL 5343 ConTEnTs

2-WiRE LEvEL TRansmiTTER PRELEvEL 5343 ConTEnTs 2-wire level transmitter PRelevel 5343 Contents EC declaration of conformity... 14 Application... 15 Technical characteristics... 15 Mounting / installation... 15 Applications... 16 Electrical specifications...

More information

Product Guide. universal. isolation. i.s. interface. temperature. display

Product Guide. universal. isolation. i.s. interface. temperature. display Product Guide universal isolation i.s. interface temperature S I G N A L S T H E B E S T display introduction PR electronics Founded in 974, PR electronics is today one of Europe s leading developers and

More information

DIN Rail Devices. CEAG Sicherheitstechnik GmbH 194

DIN Rail Devices. CEAG Sicherheitstechnik GmbH 194 DIN Rail Devices Description DIN rail devices serve as low cost signal conditioning modules between the field device and the control system. The new enclosures mounted on the 35 mm standard rail are equipped

More information

Product Guide 2008 / 2009

Product Guide 2008 / 2009 Product Guide 008 / 009 for the Process Industry Displays Trip Amplifiers / AC Power Supplies Temperature Transmitters Frequency / Pulse Modules Signal & Signal Conversion I.S. Modules: Analog, Temperature

More information

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C 34-TT-03-07 3/06 PRODUCT SPECIFICATION SHEET OVERVIEW The Honeywell STT170 series of programmable temperature

More information

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting Electrical Temperature Measurement Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting WIKA Data Sheet TE 12.03

More information

Temperature transmitter itemp PCP DIN rail TMT 121

Temperature transmitter itemp PCP DIN rail TMT 121 Technical information TI 087R/09/en 510 03671 Temperature transmitter itemp PCP DIN rail TMT 121 Universal temperature transmitter for resistance thermometers (RTD), thermocouples, resistance and voltage

More information

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C 6/07 PRODUCT SPECIFICATION SHEET OVERVIEW The Honeywell STT170 series of programmable temperature transmitters

More information

Preset counters, electronic

Preset counters, electronic The Codix 716 / 717 can be used universally. These preset pulse, tachometers or preset timers with up to 2 presets can solve a wide variety of control and monitoring tasks in every application. With their

More information

PRetrans Table of contents

PRetrans Table of contents HART TRANSPARENT REPEATER PRetrans 5106 Table of contents Warnings 16 Safety instructions 17 EC Declaration of Conformity 19 How to demount SYSTEM 5000 20 Application 21 Technical characteristics 21 Mounting

More information

Temperature head transmitter itemp PCP TMT 181

Temperature head transmitter itemp PCP TMT 181 Technical information TI 070R/09/en Mat.-Nr.: 510 01110 Temperature head transmitter itemp PCP TMT 181 Universal head transmitter for resistance thermometers (RTD), thermocouples, resistance and voltage

More information

S T T U S I N S T R U M E N T S

S T T U S I N S T R U M E N T S S T T U S I N S T R U M E N T S Welcome to the latest Status Instruments Product Guide Here at Status Instruments, we re very proud to say that we ve been making top-quality instrumentation for 30 years.

More information

STT 3000 Smart Temperature Transmitter Series STT170 Specifications

STT 3000 Smart Temperature Transmitter Series STT170 Specifications STT 3000 Smart Temperature Transmitter Series STT170 Specifications Model STT171, STT173, STT17H, STT17F, STT17C 34-TT-03-07 November 2010 Overview STT17H Features The Honeywell STT170 series of programmable

More information

CONTA-ELECTRONICS. Converter Units

CONTA-ELECTRONICS. Converter Units CONTA-ELECTRONICS Whether for manufacturing, electrical machine and plant instrumentation, control engineering, power distribution, building automation, or process engineering it is always important to

More information

CATALOGUE ISOLATING SWITCHING AMPLIFIERS POWER SUPPLIES ATEX

CATALOGUE ISOLATING SWITCHING AMPLIFIERS POWER SUPPLIES ATEX CATALOGUE ISOLATING SWITCHING AMPLIFIERS POWER SUPPLIES ATEX Registration No.: 1327-1 Testing laboratory accredited according to DIN EN 451 Reg.-No. DAT-P-48/95- For all transactions, the newest version

More information

C330 / C330X PC-Programmable Universal, 2-wire Transmitter

C330 / C330X PC-Programmable Universal, 2-wire Transmitter C330 / C330X PC-Programmable Universal, 2-wire Transmitter The IPAQ C330 transmitter is a universal, isolated, temperature transmitter with additional voltage and resistance input. Its robust design and

More information

Series 1700 PX. Selection Guide. Threshold relays. Process signal converters/isolators. Temperature converters

Series 1700 PX. Selection Guide. Threshold relays. Process signal converters/isolators. Temperature converters Selection Guide Threshold relays Process signal converters/isolators Temperature converters Process signal to pulse frequency converters/isolators Pulse frequency to process signal converters/isolators

More information

JUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter)

JUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter) JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: mail@jumo.net Internet: www.jumo.net

More information

SITRANS T measuring instruments for temperature

SITRANS T measuring instruments for temperature Overview Our field devices for heavy industrial use HART, Universal 4 to 20 ma, universal Field indicator for 4 to 20 ma signals The temperature transmitter SITRANS TF works where others feel uncomfortable.

More information

Analogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting

Analogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting Electrical Temperature Measurement Analogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting WIKA Data Sheet TE 24.01 Applications T Machinery, plant construction T Process industry

More information

Temperature Transmitter itemp RTD DIN rail TMT 127

Temperature Transmitter itemp RTD DIN rail TMT 127 Technical Information TI 095R/09/en No. 51004790 Temperature Transmitter itemp RTD DIN rail TMT 127 Temperature Transmitter for Pt100 Resistance Thermometer Application Temperature transmitter with fixed

More information

DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters

DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters Industrial Loop Isolators and Transmitters DSCL,, SCTP DSCL,, SCTP Industrial Loop Isolators and Transmitters Description Dataforth s DSCL,, and SCTP series of products is a complete family of loop and

More information

Electric thrust actuator. Electric thrust actuator ARI-PREMIO -Plus 2G. 2,2-5 kn. Electric thrust actuator. ARI-PREMIO -Plus 2G kn.

Electric thrust actuator. Electric thrust actuator ARI-PREMIO -Plus 2G. 2,2-5 kn. Electric thrust actuator. ARI-PREMIO -Plus 2G kn. ARI-PREMIO -Plus 2G Electric thrust actuator Electric thrust actuator ARI-PREMIO -Plus 2G Electric thrust actuator ARI-PREMIO -Plus 2G 2,2-5 kn Page 2 Electric thrust actuator ARI-PREMIO -Plus 2G 12-25

More information

Ouput Loop Powered Products Section C

Ouput Loop Powered Products Section C Ouput Loop Powered Products Section C An output loop powered (or signal powered) isolator derives its power from the voltage drop across the device's current loop output. Because they require no separate

More information

Transmitter for temperature and direct current variables in four-wire circuit. Contrans T TEU 315, TEU 315-Ex, TEU 325, TEU 325-Ex 11-3.

Transmitter for temperature and direct current variables in four-wire circuit. Contrans T TEU 315, TEU 315-Ex, TEU 325, TEU 325-Ex 11-3. TEU 315, TEU 315-Ex, TEU 325, TEU 325-Ex Transmitter for temperature and direct current variables in four-wire circuit Transmitters TEU 315 and TEU 325 are designed for direct and alternating voltage measurement

More information

MODEL: M1EXT. with Display M1E Series

MODEL: M1EXT. with Display M1E Series 2 Channel Super-mini Signal Conditioners with Display M1E Series THERMOCOUPLE TRANSMITTER (2 channels, PC programmable) Functions & Features Accepts direct input from a thermocouple and provides a linearized

More information

MODEL: B3HU. Space-saving Two-wire Signal Conditioners B3-UNIT

MODEL: B3HU. Space-saving Two-wire Signal Conditioners B3-UNIT Space-saving Two-wire Signal Conditioners B3-UNIT 2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER (HART communication, intrinsically safe) Functions & Features Universal input: mv, V, T/C, RTD, resistance, potentiometer

More information

B850 Boiler House Energy Monitor

B850 Boiler House Energy Monitor Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

JUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter)

JUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter) JUMO GmbH & Co. KG Delivery address: Mackenrodtstraße 14 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net

More information

SINEAX V 624 Programmable Temperature Transmitter for RTD and TC inputs

SINEAX V 624 Programmable Temperature Transmitter for RTD and TC inputs SINEAX V 6 for rail mounting in housing P/7 or P/7 St 00 II () GD Application SINEAX V 6 (Figs. and ) is designed for measuring temperature in combination with thermocouples or resistance thermometers.

More information

Temperature measurement TMD 832 head transmitter

Temperature measurement TMD 832 head transmitter Technical information TI 062R/09/en Mat.-Nr. 510 00782 Temperature measurement TMD 832 head transmitter SMART head transmitter with HART protocol for RTD, Thermocouple and mv input signals Applications

More information

Model 144H NEW. PC-Programmable Temperature Transmitter. Product Data Sheet

Model 144H NEW. PC-Programmable Temperature Transmitter. Product Data Sheet Product Data Sheet 00813-0101-4796 Model 144H PC-Programmable Temperature Transmitter FEATURES Configurable using the Model 144C Configuration Interface hardware and software Programmable via standard

More information

TF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

TF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels TF 0 / TF 0-Ex Head mounted temperature transmitters, FOUNDATION Fieldbus (H), Pt 00 (RTD), thermocouples, or independent channels 0/-8.5 EN Input Resistance thermometer (,, wire circuit) Thermocouples

More information

Temperature Transmitters - DIN Rail Mounted

Temperature Transmitters - DIN Rail Mounted XTD Features - Non-programmable Models Sensor Types: Models for thermocouple Types J, K, or T Models for RTD Type Pt100 3-wire Select from a variety of pre-configured measuring ranges Internal cold junction

More information

FieldIT Temperature Transmitter, rail mounted TH102/TH102-Ex

FieldIT Temperature Transmitter, rail mounted TH102/TH102-Ex Data Sheet 10/-8.54 EN Level 0: Information FieldIT Temperature Transmitter, rail mounted TH102/TH102-Ex HART programmable, Pt 100 (RTD), thermocouples, electrical isolation Resistance thermometer (2,

More information

Connection. Input EEx ia IIC. Sense. Fine tuning adjustment. Fine tuning amplifying. Amplifying. Adjustment. Output. Composition

Connection. Input EEx ia IIC. Sense. Fine tuning adjustment. Fine tuning amplifying. Amplifying. Adjustment. Output. Composition Converter Connection 1-channel EEx ia IIC for 4-wire and 6-wire bridges Analogue output 0/4 ma... 20 ma or 4mA...-12mA Full bridge load cells and strain gauges circuit for resistance bridges up to 17 Ω

More information

MODEL: M2EXT. Super-mini Signal Conditioners with Display Mini-M M2E Series

MODEL: M2EXT. Super-mini Signal Conditioners with Display Mini-M M2E Series Super-mini Signal Conditioners with Display Mini-M ME Series THERMOCOUPLE TRANSMITTER (PC programmable) Functions & Features Accepts direct input from a thermocouple and provides a linearized process signal

More information

SEM210 SERIES. Programmable In-head Universal Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.

SEM210 SERIES. Programmable In-head Universal Temperature Transmitter INDEX SECTION CONTENTS PAGE NO. INDEX SECTION CONTENTS PAGE NO. SEM210 SERIES 1.0 DESCRIPTION 1 2.0 SPECIFICATION 15 3.0 INSTALLATION 67 Programmable Inhead Universal Temperature Transmitter Status Instruments Ltd, Green Lane Business

More information

Temperature Input Module for Zone 1 Series 9482/32

Temperature Input Module for Zone 1 Series 9482/32 www.stahl.de > 8 channels for temperature sensors > Intrinsically safe inputs Ex ia > For Pt-, Ni- and Cu-resistance temperature detectors according to DIN, IEC and GOST in 2-, 3- and 4-wire circuits >

More information

Temperature Transmitters - Head Mounted

Temperature Transmitters - Head Mounted XTH Features - Non-programmable Models Sensor Types: Models for thermocouple Types J, K, or T Models for RTD Type Pt100 3-wire Select from a variety of pre-configured measuring ranges Internal cold junction

More information

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC Switch Amplifier Features Assembly -channel isolated barrier 30 V AC supply Dry contact or NAMUR inputs Relay contact output Line fault detection (LFD) Reversible mode of operation Up to SIL acc. to IEC

More information

MACX MCR-EX-T-UI-UP. Extract from the online catalog. Order No.:

MACX MCR-EX-T-UI-UP. Extract from the online catalog. Order No.: Extract from the online catalog MACX MCR-EX-T-UI-UP Order No.: 2865654 Freely programmable Ex-i temperature transducer with analog output and 1 limit value relay, standard configuration, resistance thermometer

More information

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With Field-mounted Two-wire Signal Conditioners B6-UNIT 8: TIIS flameproof (CE not available) Confirm selectable combinations of approval and wiring conduit types in the table. 2-WIRE UNIVERSAL TEMPERATURE

More information

C520 / C520X /C520S / C520XS HART Compatible, Universal, Dual-input 2-wire Transmitters

C520 / C520X /C520S / C520XS HART Compatible, Universal, Dual-input 2-wire Transmitters C520 / C520X /C520S / C520XS HART Compatible, Universal, Dual-input 2-wire Transmitters The 520 transmitters are universal, isolated, dual-input temperature transmitters with additional voltage and resistance

More information

Temperature Measurement

Temperature Measurement Overview Application transmitters can be used in all industrial sectors. Due to their compact size they can be installed in the connection head type B (DIN 4729) or larger. The following sensors/signal

More information

Temperature Measurement Transmitters for mounting in sensor head

Temperature Measurement Transmitters for mounting in sensor head Siemens AG 015 SITANS TH00 two-wire system, universal Overview Application SITANS TH00 transmitters can be used in all industrial sectors. Due to their compact size they can be installed in the connection

More information

Photoelectrics Amplifier, µ-processor Controlled Type PAM, 2-10 Inputs/2-10 Transistor Outputs

Photoelectrics Amplifier, µ-processor Controlled Type PAM, 2-10 Inputs/2-10 Transistor Outputs Photoelectrics, µ-processor Controlled Type PAM, 2-10 Inputs/2-10 Transistor Outputs µ-processor controlled unit for up to 10 sets of photoelectric sensors Up to 10 independent outputs Self-diagnostic

More information

Introduction ISOLATED SIGNAL CONDITIONING can significantly increase

Introduction ISOLATED SIGNAL CONDITIONING can significantly increase Introduction ISOLATD SIGNAL CONDITIONING can significantly increase your system reliability here's how: Linearizes Thermocouple and RTD signals Reduces the demands on the software to linearize the signal

More information

COMPACT-LINE. KOBO-RP Transmitter for ORP Model ARM-Z

COMPACT-LINE. KOBO-RP Transmitter for ORP Model ARM-Z KOBO-RP Transmitter for ORP Model ARM-Z measuring monitoring analysing COMPACT-LINE Measuring range -1999 to +1999 mv Switchable from ORP to ph ph or mv/orp (Oxidation Reduction Potential) and temperature

More information

Assembly. Front view. Parametrization interface. Power Bus

Assembly. Front view. Parametrization interface. Power Bus Temperature Converter Features Assembly 1-channel signal conditioner 24 V DC supply Thermocouple, RTD, potentiometer or mv input Input for PTC thermistor Current and voltage output Line fault (LFD) and

More information

â Ó itemp TC TMT128 Technical information DIN rail mounted Temperature Transmitter for Thermocouples (TC)

â Ó itemp TC TMT128 Technical information DIN rail mounted Temperature Transmitter for Thermocouples (TC) Technical information itemp TC TMT128 DIN rail mounted Temperature Transmitter for Thermocouples (TC) Application Temperature transmitter with fixed measuring ranges for converting TC input signals into

More information

Datasheet ACT20M Signal Isolation and Conversion NEW

Datasheet ACT20M Signal Isolation and Conversion NEW Datasheet ACT0M Signal solation and Conversion NEW High quality signal isolation and conversion in a slim wide housing format is now available with Weidmuller s ACT0M range. Features include worldwide

More information

FC Series Signal Conditioners

FC Series Signal Conditioners FC Series Signal Conditioners FC-33 DC Selectable Signal Conditioner with 3-way isolation Field configurable input and output ranges of 0-5V, 0-10 V, 0-20 ma and 4-20 ma with 1500 VDC isolation between

More information

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i Temperature Transmitter Series 9182 www.stahl.de > One unit for nearly all temperature sensors indivdually configurable > Intrinsically safe input [Ex ia] IIC > Signal duplication possible > Galvanic isolation

More information

Universal Intelligent 2-wire In-head Transmitters

Universal Intelligent 2-wire In-head Transmitters Universal Intelligent 2-wire In-head Transmitters Actual size IPAQ-H is a universal and intelligent 2-wire In-head transmitter for temperature and other measurement applications. IPAQ-HX is the Intrinsic

More information

Universal Intelligent 2-wire DIN Rail Transmitters

Universal Intelligent 2-wire DIN Rail Transmitters Universal Intelligent 2-wire DIN Rail Transmitters IPAQ-L is a universal and intelligent 2-wire DIN rail transmitter for temperature and other measurement applications. IPAQ-LX is the Intrinsic Safe version

More information

Data Acquisition Modules/ Distributed IO Modules

Data Acquisition Modules/ Distributed IO Modules User Manual Data Acquisition Modules/ Distributed IO Modules Future Design Controls, Inc. 7524 West 98 th Place / P.O. Box 1196 Bridgeview, IL 60455 888.751.5444 - Office: 888.307.8014 - Fax 866.342.5332

More information

COMPACT-LINE. KOBO-pH Transmitter for ph-value Model APM-Z

COMPACT-LINE. KOBO-pH Transmitter for ph-value Model APM-Z KOBO-pH Transmitter for ph-value Model APM-Z measuring monitoring analysing COMPACT-LINE Measuring range ph -1 to 14 Switchable from ph to ORP Display of ph value, mv/orp (Oxidation Reduction Potential)

More information

Head mounted Temperature Transmitter TF02/TF02-Ex

Head mounted Temperature Transmitter TF02/TF02-Ex Data Sheet Head mounted Temperature Transmitter TF0/TF0-Ex FOUNDATION Fieldbus H, Pt 00 (RTD), thermocouples, or independent channels Input Resistance thermometer (-, -, -wire circuit) Thermocouples Resistance

More information

658 Current to Position Converters

658 Current to Position Converters 658 Current to Position Converters Current to Position Converters for Solid State Switching Output Adjustable Zero, Span and Deadband Two Wire Input from Controller Operates with 90 to 1000 Ω Feedback

More information

B850 Boiler House Energy Monitor

B850 Boiler House Energy Monitor Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

Technical data. Functional safety related parameters MTTF d. Transfer characteristics. Time delay before availability. Standard conformity

Technical data. Functional safety related parameters MTTF d. Transfer characteristics. Time delay before availability. Standard conformity KFU8-DW-.D Release date: 2-2- 2:8 Date of issue: 26-8- 4_eng.xml Model Number KFU8-DW-.D Rotation Speed Monitor Features Speed monitoring up to 4 khz pre-select value with relay output and LED indicator

More information

Temperature head transmitter itemp PCP TMT 181

Temperature head transmitter itemp PCP TMT 181 Technical information TI 070R/09/en Mat.-Nr.: 510 01110 Temperature head transmitter itemp PCP TMT 181 Universal head transmitter for resistance thermometers (RTD), thermocouples, resistance and voltage

More information

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35 www.stahl.de > 16 channels can be adjusted in pairs as digital inputs or outputs > Suitable for NAMUR proximity switches, 3-wire PNP proximity switches, contacts and solenoid valves (24 V / 0.5 A). > Up

More information

itemp HART DIN rail TMT112

itemp HART DIN rail TMT112 Temperature transmitter itemp HART DIN rail TMT112 Universal temperature transmitter for resistance thermometers (RTD), thermocouples, resistance and voltage transmitters, incorporating HART protocol Application

More information

NetBiter I/O Extender 4RO 6RTD 8DIO - DAIO User Manual Revision 1.00

NetBiter I/O Extender 4RO 6RTD 8DIO - DAIO User Manual Revision 1.00 NetBiter I/O Extender 4RO 6RTD 8DIO DAIO User Manual Revision 1.00 IntelliCom Innovation AB Linjegatan 3D SE302 50 Halmstad SWEDEN Phone +46 35 18 21 70 Fax +46 35 18 21 99 email info@intellicom.se www

More information

Temperature Measurement Transmitters for mounting in sensor head

Temperature Measurement Transmitters for mounting in sensor head Siemens AG 015 Overview SITANS TH00 two-wire system, universal, HAT Application SITANS TH00 transmitters can be used in all industrial sectors. Due to their compact size they can be installed in the connection

More information

COMPACT-LINE. Transmitter for ph-value

COMPACT-LINE. Transmitter for ph-value Transmitter for ph-value measuring monitoring analysing COMPACT-LINE Measuring range ph -1 to 14 Switchable from ph to ORP Display of ph value, mv/orp (Oxidation Reduction Potential) and temperature Simple

More information

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22 www.stahl.de > 16 channels for contacts and NAMUR proximity switches (EN 60947-5-6) > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit

More information

User Manual CTP4/8/16

User Manual CTP4/8/16 KMT - Kraus Messtechnik GmbH Gewerbering 9, D-83624 Otterfing, Germany, 08024-48737, Fax. 08024-5532 Home Page http://www.kmt-telemetry.com, Email: info@kmt-telemetry.com User Manual CTP4/8/16 4/8/16-channel

More information

â itemp Pt100 TMT127 Technical information Pt100 transmitter for DIN rail mounting for high accuracy temperature monitoring

â itemp Pt100 TMT127 Technical information Pt100 transmitter for DIN rail mounting for high accuracy temperature monitoring Technical information itemp Pt100 TMT127 Pt100 transmitter for DIN rail mounting for high accuracy temperature monitoring Application Temperature transmitter with fixed measuring range for converting a

More information

Isolators A3/1.

Isolators A3/1. Temperature Transmitter Series 9182 > One unit for nearly all temperature sensors indivdually configurable > Signal duplication possible > Galvanic isolation between input, output, power supply and configuration

More information

control & display PROGRAMMABLE SENSOR CONTROLLER COMPLETE VERSATILITY OF SENSOR MANAGEMENT & DATA COMMUNICATIONS

control & display PROGRAMMABLE SENSOR CONTROLLER COMPLETE VERSATILITY OF SENSOR MANAGEMENT & DATA COMMUNICATIONS S E N S O R S PROGRAMMABLE SENSOR CONTROLLER TX9044 COMPLETE VERSATILITY OF SENSOR MANAGEMENT & DATA COMMUNICATIONS Analogue sensors, temperature devices, frequency inputs and digital sensors direct fingertip

More information

Isolated, Linearized RTD Input 7B34 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated, Linearized RTD Input 7B34 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM Isolated, Linearized RTD Input 7B34 FEATURES Amplifies, Protects, Filters, and interfaces input voltages from a wide variety of two and three-wire platinum, copper and nickel Resistor Temperature Detectors

More information

Temperature transmitter with local display RIT 261

Temperature transmitter with local display RIT 261 Technical Information TI 091R/2/ae Temperature transmitter with local display RIT 261 Universal field mounted transmitter provides an exceptional backlit temperature indication with five large digits and

More information

Contrans T TEU 471, TEU 471-Ex. Intelligent four-wire temperature transmitters EN

Contrans T TEU 471, TEU 471-Ex. Intelligent four-wire temperature transmitters EN Contrans T TEU 471, TEU 471-Ex Intelligent four-wire temperature transmitters Input/sensor connection: Resistance thermometers (2-, 3-, 4-wire circuit) Thermocouples (without, with internal/external reference

More information

MODEL: M6SXU MODEL: M6SXU [1][2] [3][4]

MODEL: M6SXU MODEL: M6SXU [1][2] [3][4] Tension-Clamp Ultra-Slim Signal Conditioners M6S Series UNIVERSAL TRANSMITTER (PC programmable) Functions & Features Maintenance-free tension clamp connection Universal input (mv, V, ma, T/C, RTD and potentiometer)

More information

Temperature Measurement

Temperature Measurement Siemens AG 015 / Product overview Transmitters for mounting in sensor head /4 SITRANS TH100 two-wire system (Pt100) /8 SITRANS TH00 two-wire system universal /15 SITRANS TH00 two-wire system universal,

More information

Universal Intelligent 2-wire DIN Rail Transmitters

Universal Intelligent 2-wire DIN Rail Transmitters Universal Intelligent 2-wire DIN Rail Transmitters IPAQ-L is a universal and intelligent 2-wire DIN rail transmitter for temperature and other measurement applications. IPAQ-LX is the Intrinsic Safe version

More information

Temperature head transmitter itemp TC TMT 188

Temperature head transmitter itemp TC TMT 188 Technical information TI 077R/24/ae No.: 510 06145 Temperature head transmitter itemp TC TMT 188 Universal head transmitter for thermocouples for an economical, high accuracy temperature monitoring. Fixed

More information

Modular Smart Interfaces

Modular Smart Interfaces Modular Smart Interfaces Automotive Energy & Power Analysis Aerospace & Defense Transportation General Test & Measurement Modular Smart Interfaces MSI Series Modular Smart Interfaces (MSI) bring an expanded

More information

Isolated, Linearized Thermocouple Input 7B47 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated, Linearized Thermocouple Input 7B47 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM Isolated, Linearized Thermocouple Input 7B47 FEATURES Interfaces, amplifies and filters input voltages from a J, K, T, E, R, S, B or N-type thermocouple. Module provides a precision output of either +1

More information

Rail mounted Temperature Transmitter TH102/TH102-Ex

Rail mounted Temperature Transmitter TH102/TH102-Ex Data Sheet 10/-8.54 EN Rail mounted Temperature Transmitter TH102/TH102-Ex HART programmable, Pt 100 (RTD), thermocouples, electrical isolation Input Resistance thermometer (2, 3, 4 wire circuit) Thermocouples

More information

Isolated, Thermocouple Input 7B37 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated, Thermocouple Input 7B37 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM Isolated, Thermocouple Input 7B37 FEATURES Interfaces, amplifies, and filters input voltages from a J, K, T, E, R, S, or B-type thermocouple. Module provides a precision output of either +1 V to +5 V or

More information

D1072. SIL 2 Temperature Signal Converter, Duplicator, Adder/Subtractor DIN-Rail Models D1072S, D1072D. Front Panel and Features:

D1072. SIL 2 Temperature Signal Converter, Duplicator, Adder/Subtractor DIN-Rail Models D1072S, D1072D. Front Panel and Features: Characteristics: Front Panel and Features: Ordering Information: Model: D7 D7 General Description: The single and dual channel DIN Rail Temperature Signal Converter D7S and D7D accepts a low level dc signal

More information

Flow rate Indicator / Totalizer

Flow rate Indicator / Totalizer Datasheet ER100(M) Robust explosion proof indicator Flow rate Indicator / Totalizer with linearization, analog and pulse signal outputs Advantages Save time and gain flexibility with the easytooperate

More information

Data Sheet KFD2-UFC-EX1.D. Supplied by. .com. Call us on +44 (0)

Data Sheet KFD2-UFC-EX1.D. Supplied by. .com. Call us on +44 (0) Data Sheet KFD-UFC-EX1.D Supplied by.com Call us on +44 (0)118 916 940 Email info@47able.com Frequency Converter with Trip Values Features Assembly 1-channel isolated barrier 4 V DC supply (Power Rail)

More information

Technical Information RMA42

Technical Information RMA42 TI00150R/09/EN/05.16 71315973 Products Solutions Services Technical Information RMA42 Process transmitter with control unit Digital process transmitter for monitoring and visualizing analog measured values

More information

Actuator ICAD 600A / ICAD 600A-TS / ICAD 1200A

Actuator ICAD 600A / ICAD 600A-TS / ICAD 1200A Installation Guide Actuator ICAD 600A / ICAD 600A-TS / ICAD 1200A 027R9966 ICAD 600A ICAD 600A-TS ICAD 1200A 027R9966 ICAD 600A / ICAD 600A-TS ICAD 1200A Fig. 1 Fig. 2 Note: When mounting the ICAD make

More information

Advanced Ladder Logic Full IEC Languages 25A for <1 24 VDC DC Switched

Advanced Ladder Logic Full IEC Languages 25A for <1 24 VDC DC Switched EXL6 OCS Datasheet for HE- EXL1E0, HE- EXL1E2, HE- EXL1E3, HE- EXL1E4, HE- EXL1E5, HE- EXL1E6 HEXT371C100, HEXT371C112, HEXT371C113, HEXT371C114, HEXT371C115, HEXT371C116 1. Specifications Required Power

More information

Dial-type digital bar graph. LEDs for Open Collector, Relays and Warning Indicator

Dial-type digital bar graph. LEDs for Open Collector, Relays and Warning Indicator Specifications General Input Channels One Input Types Digital (S 3 L) Serial ASCII, TTL level, 9600 bps Frequency Range 0.5 to 1500 Hz Accuracy 0.5% of reading Measurement Types Flow, ph/orp, Conductivity/Resis

More information

User s Guide DRST-FR. Programmable Converter. Shop online at omega.com. For latest product manuals:

User s Guide DRST-FR. Programmable Converter. Shop online at omega.com.   For latest product manuals: TM User s Guide Shop online at omega.com e-mail: info@omega.com For latest product manuals: www.omegamanual.info DRST-FR Programmable Converter U.S.A. Headquarters: omega.com info@omega.com Servicing North

More information

Model FLSC-C3-XX. DC Powered Microprocessor Controlled Transmitter

Model FLSC-C3-XX. DC Powered Microprocessor Controlled Transmitter Model FLSC-C3-XX DC Powered Microprocessor Controlled Transmitter CONTENTS. Introduction----------------------------------------------------------------- 2 2. Specifications ---------------------------------------------------------------

More information

SINEAX V 604 Programmable universal transmitter

SINEAX V 604 Programmable universal transmitter for DC currents or voltages, temperature sensors, remote sensors or potentiometers 0102 II (1) G Application The universal transmitter SINEAX V 604 (Figures 1 and 2) converts the input variable a DC current

More information

Product manual wire programmable RTD transmitter

Product manual wire programmable RTD transmitter Product manual 5332 2-wire programmable RTD transmitter PERFORMANCE MADE SMARTER TEMPERATURE I.S. INTERFACES COMMUNICATION INTERFACES MULTIFUNCTIONAL ISOLATION DISPLAY No. 5332V100-UK From serial no: 181903001

More information

WAVESERIES Signal converters

WAVESERIES Signal converters WAVESERIES Overview WAVESERIES Signal converters Isolation and conversion of analogue signals enclosed in a rail-mounted WAVEBOX housing WAVESERIES products are well suited for users seeking an analogue

More information

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals Accessories High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals WIKA data sheet AC 80.03 Applications Machine building

More information

Product Manual 5202 Pulse isolator

Product Manual 5202 Pulse isolator Product Manual 50 Pulse isolator PERFORMANCE MADE SMARTER TEMPERATURE I.S. INTERFACES COMMUNICATION INTERFACES MULTIFUNCTIONAL ISOLATION DISPLAY No. 50V108-UK From serial no.: 030481661 6 Product Pillars

More information

BAPI-Stat 4 X-Combo, Room %RH and Temp. Sensor BA/BS4XC Installation & Operating Instructions

BAPI-Stat 4 X-Combo, Room %RH and Temp. Sensor BA/BS4XC Installation & Operating Instructions Overview and Identification The BAPI-Stat 4 X-Combo () Room Unit features 4 output channels and optional local indication of temperature and humidity. Additional options include Temperature Setpoint, Humidity

More information

0 2 1 â Ó. itemp HART TMT182. Technical Information

0 2 1 â Ó. itemp HART TMT182. Technical Information Technical Information itemp HART TMT182 Temperature head transmitter Head transmitter for resistance thermometers (RTD), thermocouples (TC), resistance and voltage transmitters (mv), HART -protocol, for

More information